HomeMy WebLinkAbout2175 CAMINO VIDA ROBLE; ; CB010586; Permit08-15-2006
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB010586
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
Applicant:
LEIN RICK
PO BOX 930
POWAYCA 92074
619-339-7425
2175 CAMINO VIDA ROBLE CBAD
COMMIND Sub Type: COMM
2130501300 Lot#: 0
$500,092.00 Construction Type: NEW
Reference #:
PACIFIC BELL
NEW 1ST & 2ND STORY ADDITION -16,132 SF
Owner:
PACIFIC BELL
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
WITHDRAW
02/09/2001
JM
CALIFORNIA STATE ASSESSED 00000
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
$1,781.17 Meter Size
$0.00 Add'l Reel. Water Con. Fee
$1,157.76 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$105.02 PFF {3105540}
$0.00 PFF {4305540}
$0.00 License Tax {3104193)
$0.00 License Tax {4304193)
$0.00 Traffic Impact Fee (3105541)
$0.00 Traffic Impact Fee (4305541)
$0.00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
SO.00 Master Drainage Fee
Sewer Fee
$0.00 Redev Parking Fee
$0.00 Additional Fees
HMP Fee
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
??
$3,043.95
Total Fees:$3,043.95 Total Payments To Date:$1,157.76 Balance Due:$1,886.19
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions, If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1 635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO/^/fffl/"* 5$£>
EST.VAL 'irtn&ll^ . __ ,7£^>7(Plan Ck. Deposit
Validated By.
Date
*?
/ /
-- ..-.--n* f&ciLtr -,<
PA&nc.
Address (include Bldg/Suite ft)Business Name (at this address^.
Legal Description Lot No.Subdivision Name/Number Unit No. Phase No.U-t^H'btal # of unitej.
Assessor's Parcel #Existing Use
l&t I3A
Proposed Use
Description of Work SQ. FT.
iji&f i§c<5irtM^^ •- •; .-•:s •••" •: ;v'
#of Stories # of Be # of Bathrooms
City State/Zip Telephone Fax #
Name Address City State/Zip
Name Address City State/Zip Telephone #
6ij:Mf $8H11<iA'd^^ ";••":' " , • •• ; .' •' • :L::';"';::-':: :':r -• •••>'::':':'~- "=';; '.:.;T -•:'•• i::SJ5' n! ;>:""'::L»^ >r-l" \ \: ;.d'H r: ";";= =;,;, -;''":,'.,::: -. ;: ;,. •.-.$,.,.:.. •'
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars I$500)).
Name Address
State License # License Class
Designer Name Address
State License #
City State/Zip Telephone #
City Business License #
City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
[~] I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company _ Policy No. _ Expiration Date _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE _ DATE
'. . -. : -. ••'.::•./=.•.; '.:"."•'••• "• •••'• '. : •''-••> i : '. ; =!. !•' '. '•:"" ••/• - •".'''••" :r: vf .'::'-.,..:•• " ^:'M •;.= '"
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
O I am exempt under Section _ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):_
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO
Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? D YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
. ..
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME _ LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced fora perjfjd of 180 days (Section 106.4.4 Uniform Building Code). / /
APPLICANT'S SIGNATURE DATE 79
WHITE: File YELLOW: Applicant PINK: Finance
12/10/2001
LEIN RICK
PO BOX 930
POWAY CA92074
Re:
Application Date: 02/09/2001
Plan Check #: CB010586
Address: 2175 CAMINO VIDA ROBLE
Expiration Date: 02/09/2002
Permit Type: COMMIND
Description: PACIFIC BELL
NEW 1ST & 2ND STORY ADDITION - 16,132 SF
You applied to have your plans checked on the date noted above. To date, the related building
permit has not been obtained. The original plan review application will expire as no building permit
has been issued.
Plans submitted and not retrieved from the building department prior to the plan check expiration
date noted above will be destroyed.
The provisions of sections 304 (d) of the Uniform Building Code state:
"Section 304 9d) Expiration of Plan Review
Applications for which no permit is issued within one year following the date of
application shall expire by limitation, and plans and other data submitted for review
may thereafter be returned to the applicant or destroyed by the Building Official.
In order to renew action on an application after expiration, the applicant shall
resubmit plans and pay a new plan review fee."
In order to provide better service, please indicate your handling choice for the plans originally
submitted and return this letter to the Building Department.
/Jjr Pro/ect Abandoned - I will pick up plans within 10 days
Project Abandoned - Plans may be destroyed.
If you have any questions, please contact the Building Department at (760) 602-2718.
Raenette Abbey
Building Department
EsGil Corporation
In Partners/tip with government for fyuitding Safety
DATE: JUNE 22, 2001 OAPPUQANT
JURISDICTION: CARLSBAD Q PLAN REVIEWER
U FILE
PLAN CHECK NO.: 01-586 SET: IV
PROJECT ADDRESS: 2175 CAMINO VIDA ROBLE
PROJECT NAME: PACIFIC BELL EXPANSION
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck. _
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
X] Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
X| REMARKS:
By: All Sadre Enclosures:
Esgil Corporation
D GA D MB D EJ D PC LOC51 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576
EsGil Corporation
In Partnership with, government for Quitting Safe
DATE: MAY 28, 2001 Q ATOJCANT
JURISDICTION: CARLSBAD Q PLAN REVIEWER
Q FILE
PLAN CHECK NO.: 01-586 SET: HI
PROJECT ADDRESS: 2175 CAMINO VIDA ROBLE
PROJECT NAME: PACIFIC BELL EXPANSION
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck. PLEASE SEE BELOW
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
XI The applicant's copy of the check list has been sent to:
RICK LIEN P.O. BOX 930, POWAY, CA
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
XI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: RICK LIEN Telephone #: 619-339-7425
Date contacted: 5/2^/oi (by: fc, ) Fax #:
Mail .-^Telephone ^-Fax In Person
XI REMARKS: #1): The project architect need to sign the plans in addition to stamping them;
#2): Show how the soils engineer's recommendations are incorporated into the plans and
specifications.
By: All Sadre Enclosures:
Esgi! Corporation
D GA D MB n EJ D PC 5/23 tmsmfl.dot
9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
EsGil Corporation
In 3?artnersfiip with government for <Bui[ding Safety
DATE: APR. 26, 2001 Q APPLICANT
JURISDICTION: CARLSBAD a PLAN REVIEWER
Q FILE
PLAN CHECK NO.: 01-586 SET: II
PROJECT ADDRESS: 2175 CAMINO VIDA ROBLE
PROJECT NAME: PACIFIC BELL EXPANSION
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
X] The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck. PLEASE SEE BELOW
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
XI The applicant's copy of the check list has been sent to:
RICK LIEN P.O. BOX 930, POWAY, CA
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: RICK LIEN (V.in.} Telephone #: 619-339-7425
Fax #:
Mail *" Telephone ^ Fax In Person
REMARKS: Please see attached for remaining items from previous list.
By: All Sadre Enclosures:
Esgil Corporation
D GA D MB n EJ D PC 4/19 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576
CARLSBAD 01-586
APR. 26, 2001
1. Please submit three sets of revised/ signed plans to the Jurisdiction Building
Department.
2. Please verify with the city that sprinklers are not required for this project.
3. Please note the name & information of the Special Inspection team on plans, per
response list. Section 106.3.5.
4. Note on the plans: "When serving more than 100 sprinkler heads, automatic
sprinkler systems shall be supervised by an approved central, proprietary or
remote, station service, or shall be provided with a local alarm which will give an
audible signal at a constantly attended location." Section 904.3.
5. Please change note # 15 to 27 on A2.2 for stairs.
6. Please revise note # 27 on A2.1 to state 1-hour rated existing stairs & vestibule
with 1-hour doors (instead of 3/4hr.) subject to field verification. Section 1004.2.2.
7. Provide a letter from the soils engineer confirming that the foundation plans have
been reviewed and that it has been determined that his recommendations have
been incorporated into the plans. Also submit a copy of the soils report to EsGil.
8. The extent of detail 11/S3.2, as shown on S2.1, near grid point 24-F is incorrect.
9. Please indicate the extent of wall footings beyond grid points 24-F & 22-K.
10. Please provide cold joint details and references between the masonry walls and
concrete columns, orshearwalls. I.e., details 14/S3.1, etc. Sec. 1633.2.4.1.
11. If concrete walls are used to provide lateral resistance, then please clarify details
4 or 9/S3.1, in which masonry walls by default will become lateral force resisting
elements..
12. If concrete walls are providing lateral resistance, please show how Section
1633.2.4 is satisfied for the CMU walls.
13. Provide a schematic on plans showing the chord bar size, number & extent for
each level. [Details 3, 4, 5, 8, or 9/S3.2, are not sufficient for this purpose].
• To speed up the review process, note on this list {or a copy) where each correction item has been
addressed, i.e., plan sheet, note or detail number, calculation page, etc. If you have any questions
regarding these plan review items, please contact All Sadre at Esgil Corporation. Thank you.
EsGil Corporation
In yartn.ersfi.ip witk government for 'BuiCding Saftty
DATE: FEB. 23, 2001 Q ABLJCANT
JURISDICTION: CARLSBAD a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 01-586 SET:!
PROJECT ADDRESS: 2175 CAMINO VIDA ROBLE
PROJECT NAME: PACIFIC BELL EXPANSION
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
XI The applicant's copy of the check list has been sent to:
RICK LIEN P.O. BOX 930, POWAY, CA
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
XI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: RICK LIEN (y.Mj Telephone #: 619-339-7425
Date contacted:^)2.^0» (by:^ ) Fax #:
Mail ..Jtetephone <_^ Fax In Person
REMARKS:
By: All Sadre Enclosures:
Esgil Corporation
13 GA [>3 MB D EJ D PC 2/12 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576
CARLSBAD 01-586
FEB. 23, 2001
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK NO.: O1-586
OCCUPANCY: B
JURISDICTION: CARLSBAD
USE: SWITCHING FACILITY
TYPE OF CONSTRUCTION: III-1HR. ACTUAL AREA: 16,132 addition
ALLOWABLE FLOOR AREA: 18KX2X3 STORIES: 2
SPRINKLERS?: Y
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 2/9
DATE INITIAL PLAN REVIEW
COMPLETED: FEB. 23, 20O1
HEIGHT: 36'
OCCUPANT LOAD: 36
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 2/12
PLAN REVIEWER: All Sadre
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
CARLSBAD 01-586
FEB. 23, 2001
1. Please make all corrections on the original tracings and submit three new
complete sets of prints, to: The Jurisdiction Building Department.
2. Please revise the allowable area calculations on cover sheet of plans according
to the next item.
3. Please include the following code information on the Title Sheet for the proposed
building addition/ remodel:*
* Height 36*
4 Sprinklers: Yes (by city ordinance)
* Please show the actual existing floor area per level on plans.
* Note the existing building is Type 111-1 Hour subject to filed verification.
* Specify the total floor area of new & existing on plans per level.
» Allowable Area Justification per level: I.e., base value = 18,000 x 3(for Sprinklers/ floor)
x 1.5(for 2-60' yards). Show this is less than the total floor area per level.
* For total allowable areas = 18.000 x 2(for sprinklers) x 2(stories)x 1.5(for 2-60' yards}
less than the total actual areas, thus OK as shown on plans.
» Provide the allowable area calculations for B/H2 occupancies as well. Show the total
ratios do not exceed one. Section 504.3.
4. Provide a statement on the Title Sheet of the plans that this project shall comply
with the 1998 edition of the California Building Code (Title 24), which adopts the
1997 UBC, UMC and UPC and the 1996 NEC.
5. Provide a note on the plans indicating no hazardous materials will be stored
and/or used within the building which exceed the quantities listed in UBC Tables
3-D and 3-E.
6. When special inspection is required, the architect or engineer of record shall
submit the name & information of the Special Inspection team to the building
official for approval prior to issuance of the building permit. Section 106.3.5.
7. Provide a statement on the site plan stating: "All property lines, easements and
buildings, both existing and proposed, are shown on this site plan."
8. Clearly dimension building setbacks from property lines, street centerlines, and
from all adjacent buildings and structures on the site plan.
9. Clearly show the yards that are being used for allowable area increases, as
necessary.
10. Provide a note on the plans or on the finish schedule, stating, "Wall and ceiling
materials shall not exceed the flame spread classifications in UBC Table 8-B."
11. Note on plans that suspended ceilings shall comply with UBC Tables 25-A & 16-O.
CARLSBAD 01-586
FEB. 23, 20O1
12. On the cover sheet of plans, specify any items that will have a deferred submittal
(stairs, sprinklers, etc. Also note the following on plans, per Sec. 106.3.4.2:
"Submittal documents for deferred items shall be submitted to the architect or
engineer of record, who shall review them and forward them to the building
official with a notation indicating that the deferred documents have been
reviewed and that they have been found to be in general conformance with the
design of the building. The deferred items shall NOT be installed until their
design and submittal documents have been approved by the building official." .
13. Note on the plans: "When serving more than 100 sprinkler heads, automatic
sprinkler systems shall be supervised by an approved central, proprietary or
remote, station service, or shall be provided with a local alarm which will give an
audible signal at a constantly attended location." Section 904.3.
14. Please provide details of the rated floor covering at the building separation
between the new & existing construction. Also specify an ICBO, UL, or equal,
approval number for this assembly.
15. The location of the door for the chiller room, on sheet D2 (grid line 6), does not
match what is shown on the site plans.
16. The floor areas as noted on sheet A1 do not match the cover sheet of plans.
17. Please clarify all details referenced to xx/xx, etc. through out the plans.
18. The second floor stairs on sheet A2.2, by grid line 18 needs to be rated,
otherwise, The occupants from the second level go through too many adjoining
rooms before exiting the building. Section 1004,2.2.
19. Please show the stairs and vestibule on sheet A2.1 is one hour rated with 1-hour
doors.
20. The door location out of the engine room per A2.2 (on gridline K) is not shown
properly on 3/A3.1.
21. Please label all occupancy separation walls and floors on plans along with their
required hourly rating.
22. Please note on plans that the penetration of occupancy separation walls and
floors require smoke & fire dampers on plans.
23. Please label all rated shafts on plans along with their required hourly rating.
24. Please show panic hardware for doors from H2 occupancy. Also show complying
ramps details on plans to rooms with (6") curbs.
CARLSBAD 01-586
FEB. 23, 2001
25. Provide a letter from the soils engineer confirming that the foundation plan and
specifications have been reviewed and that it has been determined that the
recommendations in the soil report are properly incorporated into the plans.
26. Show diameter and end distance for power driven pins on plans. Section
106.3.3.
27. Please provide a schedule on plans indicating the required lap length for Class A
& B as well as various locations (top or bottom) and different concrete strength,
e.g., 3 & 5 ksi per plans.
28. Note on the foundation plan that "Prior to the contractor requesting a Building
Department foundation inspection, the soils engineer shall advise the building
official in writing that:
a) The building pad was prepared in accordance with the soils report,
b) The utility trenches have been properly backfilled and compacted, and
c) The foundation excavations comply with the intent of the soils report."
29. Please note on S2.1 the continuous footing width is 2'-0", U.N.O.
30. Please specify where detail 20/S3.2 is per reference on S2.1.
31. Detail 13/S3.2 as referenced on S2.1, by grid point K-18 is incorrect. Please
provide a modified detail to reflect the outline of the existing stair footing, etc.
32. Please indicate where the shear wall footing reinforcement transitions between
grid points 24-F & 24-E on sheet S2.1. [Please see details 11 and 12/S3.2 as
referenced at these locations]. Similarly, for the shear walls on grid lines A, 21, &
K.
33. Please clarify details 9 and 14/S3.2 as referenced on grid line A, sheets S2.1 &
S2.2. [The shear wall reinforcement size and spacing are different on these
details].
34. It is not clear why drop panels are only shown on grid points 24-D & F as well as
22-F & 23-E, sheet S2.3.
35. Please show reinforcement layout for the drop panel on S3.1.
36. Please clarify CC1 as labeled on details 11 & 12/S3.1.
37. Please show that the 2" seismic separation (per 5/S3.1) is adequate. UBC, Sec.
1633.2.11.
CARLSBAD 01-586
FEB. 23, 2001
38. Please show how the building separation is maintained adjacent to existing
building on all relevant details similar to 17/S3.1, etc.
39. Where are details 1 & 2/S1.1 as referenced on 13 & 14/S3.1?
40. Please show details on plans for columns with 12 bars, per column schedule.
41. Please note where details 11 & 12/S3.1 are referenced on plans.
42. Please provide cold joint details and references between the masonry walls and
concrete columns or shear walls. I.e., details 14, 19/S3.1,etc. Sec. 1633.2.4.1.
43. If concrete walls are used to provide lateral resistance, then please clarify details
similar to 4 or 9/S3.1, in which masonry walls by default will become lateral force
resisting elements.
44. Please show chord bar size and layout on plans.
45. Please show drag bar size and extent on plans.
46. Please show chord elements are designed per Section 1633.2.6.
47. If the concrete walls are providing lateral resistance, please show how Section
1633.2.4 is satisfied for the block walls.
48. Please dimension the separation between block walls and the adjacent concrete
walls on plans. I.e., see details 4, 9,12, 14/S3.2, etc.
49. Please note where detail 10/S3.2 is referenced on plans.
50. Please show the structural wall design complies with Section 1921.6.
51. Please provide a summary for the lateral design in calculations indicating the role
of block walls in supporting the gravity & lateral forces.
52. Please provide an index (or table of content) in structural calculations for design
of beams, columns, slabs, footings, lateral, etc.
53. More corrections may be necessary after completed plans are submitted for
review. Please see attached for P/M/E and HC items.
• To speed up the review process, note on this list (or a copy) where each correction item has been
addressed, i.e., plan sheet, note or detail number, calculation page, etc. If you have any questions
regarding these plan review items, please contact All Sadre at Esgil Corporation. Thank you.
CARLSBAD 01-586
FEB. 23, 2001
* ELECTRICAL PLAN REVIEW
• 1996 NEC
• JURISDICTION: CARLSBAD DATE: 02/26/01
• PLAN REVIEW NUMBER: 01-586
• PLAN REVIEWER: MORTEZA BEHESHTI
1. Show or note on the plans the method used to limit fault currents to 10,000 amps
on branch circuits. Show the fuse letters if used to limit fault current (i.e. , JJN,
AST, LPN). Also note on the plans that circuit breakers used in the subpanels will
be listed for series combination with the current limiting main fuses or circuit
breakers.
2. On sheet E8.0, please indicate which equipment is new?
3. On sheet E8.1, please include the two new panel loads on the "TPA" load
summary shown on the same sheet.
4. Remove conduit and feeders for the existing chiller #2 shown on sheet E8.2.
5. On sheet E8.2, include "HBA-11" load on load summary for "HBA" and complete
its panel schedule.
6. On sheet E8.3 reference is made to sheet E7.3C at both switchboard single
lines. There is no sheet E7.3C in the submitted set. Please correct.
7. Specify the wiring method you intend to use for this project. Indicate the type of
conduit to be used when exposed or buried underground, etc. (i.e., EMT, Metal
Flex, NMC etc.). NEC 110-3(a) and (b)
8. Submit complete panel schedule(s) for all new panels and existing panels if
being used.
9. Rebar or ground rods are not acceptable grounding electrode(s) for commercial
applications in the City of Carlsbad. Please describe what the "UFER" ground
will be. (footage, conductor material and size, depth in footing.)
10. In all occupancies where the exit system serves 100 or more occupants, provide
a minimum of 1 foot-candle of emergency illumination at the floor level and
specify a second source of power for the emergency illumination (battery or
generator). UBC 1003.2.9.2 & NEC 700-16.
CARLSBAD 01-586
FEB. 23, 2O01
11. Note the following requirements on the prints for panelboards supplying fire
alarm equipment: Lockable cover, identified circuit breaker (red), and a breaker
"lock-off" device to be installed.
12. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures
will be identified as series-rated and labeled in accordance with NEC 110-22"
and " The overcurrent devices shall be AIC rated per manufacturers, labeling of
the electrical equipment".
13. Note that pull-section taps are factory installed, field installed per factory
specifications (available at the site), or to be certified by a third party (NRTL
certified) testing laboratory.
Note: If you have any questions regarding this electrical plan review list please contact
Morteza Beheshti at (858) 560-1468. To speed the review process, note on this
list (or a copy) where the corrected items have been addressed on the plans.
PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
PLAN REVIEWER: Eric Jensen
PLUMBING (1997 UNIFORM PLUMBING CODE)
1. The water supply piping to the restrooms is undersized for the flush valve urinal
shown on the floorplans. Please address.
MECHANICAL (1997 UNIFORM MECHANICAL CODE)
2. Clarify what is installed interior of the existing "power" room 106. The new duct
shown installed may nit infringe upon the NEC 384-4 clearances,
3. City approval will be necessary for the installation of the roof mounted 5" piping
shown on sheet M7.
4. Correct sheet D2 to accurately reflect the existing/new installation of the
mechanical chillers.
5. Include the weight for air handler 2 on the mechanical schedule (when in
operation).
Note: If you have any questions regarding this Plumbing, Mechanical, and Energy plan review list please
contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where
the corrected items have been addressed on the plans.
CARLSBAD 01-586
FEB. 23, 20O1
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD PLAN CHECK NO.: 01-586
PREPARED BY: All Sadre DATE: FEB. 23, 2001
BUILDING ADDRESS: 2175 CAMINO VIDA ROBLE
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: III-1HR.
BUILDING
PORTION
equip, rooms
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
16132
16132
16132
cb
Valuation
Multiplier
29.00
3.60
1.80
By Ordinance
1994 UBC Building Permit Fee | ^
Reg.
Mod.
VALUE ($)
467,828
58,075
29,038
554,941
$2,184.70
1994 UBC Plan Check Fee
Type of Review:
^Repetitive Fee
v Repeats
Complete Review
D Other
D Hourly
Structural Only
Hour(s) *
Esgil Plan Review Fee
$1,420.06
$1,136.04
Comments:
Sheet 1 of 1
macvalue.doc
BUILDING PLANCHECK CHECKLIST
DATE:PLANCHECK NO.: CB
BUILDING ADDRESS: cg7«S
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER:QSQ-L'5 ESt? VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please sea trig, attached report of deficiencies
marked withJa^Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
Date:
Date
Date:
: 7/5/0)
f
FOR OFFICIAL USE ONLY
By:
ENGINEERING AUTHOroZATIPN TO ISSUE BUILDING PERMIT;
• ••=-.., V ••... . :: ••.---"• ..:.':.' -:• :••'. .- : ..Date;
ATTACHMENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
ENGINEERING DEPT. CONTACT PERSON
Name: JOANNE JUCHNIEWICZ
City of Carlsbad
Address: 1635 Faraday Avenue. Carlsbad, CA 92008
Phone: (760) 602-2775
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
A-4
HAWORD^DOCS\CHKLST\Buidlng Ptandwdt CWst Font (Genertc).doc
BUILDING PLANCHECK CHECKLIST
>RD
D
SITE PLAN -
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow
B. Existing & Proposed Structures
C. Existing Street Improvements
D. Property Lines
E. Easements
2. Show on site plan:
F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
H. Existing or proposed sewer lateral
I. Existing or proposed water service
J. Existing or proposed irrigation service
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
H:\WORIJOOCS\CHKLST\BLJidinQ Ptancteck CMst Fwm {GenericJ.doc
BUILDING PLANCHECK CHECKLIST
|ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE
N^ V/ r-,S CM LJ 4a. Project does not comely with the followingEngineering Conditions of approval for
/\ /\ Project No. CO? l^y^Dj Vr fi-eSr. /Jc?. ^/^^^
D D 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
> f°r remodels with a value at or exceeding $15.000. pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 W x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
^ i construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section
6\ 18.40.040.
Public improvements required as follows: .^____
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
H:\WORDMJOCS\CHKLST\BulliJlng Planchot* CW« Form (RIDDLE - HARVEY 7-12-00).dOC
BUILDING PLANCHECK CHECKLIST
IST 2ND 3rd
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
D D D 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $280 so we may
prepare the necessary Neighborhood Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Neighborhood Improvement Agreement will include the following:
G 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Neighborhood Improvement Agreement completed by:
Date:
D D n 6d- No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
D D D 7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
H:\WORmDOCS\CHKLST18uMlng Ptancfwck Cklst Form (RIDDLE - HARVEY T-12-001.doc
)ND1ST
D
D D
>RD
BUILDING PLANCHECK CHECKLIST
7d .No Grading Permit required.
7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-Way permit required for: ^ ____
D D 9- INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
D D D
D D D
10.NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
11. Q Required fees are attached
Q No fees required
WATER METER REVIEW
12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
• All single family dwelling units received "standard" 1" service with 5/8" service.
HAWORD\DOCfflCHKLSTiBuWinB PtanchM* CWtt Farm (Generic).**;
BUILDING PLANCHECK CHECKLIST
1ST )ND )RD
D
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
• Maximum service and meter size is a 2" service with a 2" meter.
• If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand, (manifolds are considered on case by case basis to limit
multiple trenching into the street).
12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
1. If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W". The irrigation service should
look like:
STA 1+00 Install 2" service and
2.
3.
1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
H:\WORDUX)CS\CHKLS'nBuUlng Planch** cwtt Forni (Oenertc)Jtoc
BUILDING PLANCHECK CHECKLIST
* ST 9ND 3RD
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future.
D n n 12c. Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above.
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
D D D I3- Additional Comments:
H:\WORD\DOCS\CHKLSmMJIng Rant*** CHtt form (Genertc).doe
D
D
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
Estimate based on unconfirmed information from applicant.
Calculation based on building plancheck plan submittal.
Address:Bldg. Permit No.
Prepared by:Date:Checked by:Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq. Ft./Units:
Types of Use: Sq. Ft./Units:
APT CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq. Ft./Units:
Types of Use:Sq. Ft./Units:
EDU's:
EDU's:
ADT's:
ADT's:
FEES REQUIRED:
WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO
PARK AREA & #:D 1. PARK-IN-LIEU FEE
FEE/UNIT:X NO. UNITS:= $
D 2. TRAFFIC IMPACT FEE
ADT's/UNITS:X FEE/ADT:= $
D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1
ADT's/UNITS: X FEE/ADT:
DIST. #2 DIST. #3
= $
D 4. FACILITIES MANAGEMENT FEE
UNIT/SQ.FT.:
D 5. SEWER FEE
EDU's:
BENEFIT AREA:
EDU's:
ZONE:
X FEE/SQ.FT./UNIT:= $
X FEE/EDU:
X FEE/EDU:
D 6. SEWER LATERAL ($2,500)
D 7. DRAINAGE FEES PLDA :
ACRES:
D 8. POTABLE WATER FEES
UNITS CODE CONNECTION FEE
= *.
= $.
= $
HIGH /LOW
FEE/AC:= $
METER FEE SDCWA FEE IRRIGATION
Word\Doc*\MI»fonns\FM Calculation Worksheet
I Of 2
Rev. 7/14/00
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
D 9. RECLAIMED WATER FEES
UNITS CODE CONNECTION FEE METER FEE
TOTAL OF ABOVE FEES*: $
*NOTE: This calculation sheet is NOT a complete list of all fees which may be due.
Dedications and Improvements may also be required with Building Permits.
2 of 2
Word\Docs\Mlsfomu\FM Calculation Workihwt Rev. 7/14/00
1 PLANNING COMMISSION RESOLUTION NO. 4923
2 A RESOLUTION OF THE PLANNING COMMISSION OF THE
3 CITY OF CARLSBAD, CALIFORNIA, APPROVING A
CONDITIONAL USE PERMIT AMENDMENT TO ALLOW AN
4 EXPANSION OF THE EXISTING TELEPHONE ELECTRONIC
SWITCHING FACILITY IN THE PLANNED INDUSTRIAL
5 ZONE ON PROPERTY GENERALLY LOCATED ON THE
6 SOUTH SIDE OF CAMINO VIDA ROBLE JUST WEST OF
YARROW DRIVE IN LOCAL FACILITIES MANAGEMENT
7 ZONES.
CASE NAME: PACIFIC BELL
8 CASE NO.: CUP 154(D)
9 WHEREAS, Pacific Bell, "Developer,"/"Owner," has filed a verified application
10
with the City of Carlsbad regarding property described as
11
Lot 15 of Carlsbad Tract No. 73-49 (C.C. & F. Palomar1 O V1-6 Airport Business Park) Unit No. 1 in the City of Carlsbad,
j 3 County of San Diego, State of California, according to the Map
thereof No. 8054 filed in the office of the Recorder of San Diego
14 County, December 31,1974
15 ("the Property"); and
WHEREAS, said verified application constitutes a request for a Conditional Use
17
Permit Amendment as shown on Exhibits "A" - "L" dated February 21, 2001, on file in the
18
Carlsbad Planning Department PACIFIC BELL - CUP 154(D), as provided by the conditions
19
20 of approval of CUP 154(C) and Chapter 21.42 and/or 21.50 of the Carlsbad Municipal Code; and
21 WHEREAS, the Planning Commission did, on the 21st day of February 2001,
22 hold a duly noticed public hearing as prescribed by law to consider said request; and
^•3•" WHEREAS, at said public hearing, upon hearing and considering all testimony
24 and arguments, if any, of all persons desiring to be heard, said Commission considered all factors
25
relating to the CUP amendment.
26
WHEREAS, on August 7, 1996, the Planning Commission approved CUP
28 154(C), as described and conditioned in Planning Commission Resolution No. 3960.
1 NOW, THEREFORE, BE IT HEREBY RESOLVED by the Planning
2 Commission of the City of Carlsbad as follows:
3
A) That the foregoing recitations are true and correct.
4
B) That based on the evidence presented at the public hearing, the Commission
APPROVES PACIFIC BELL - CUP 154(D) based on the following findings
5 and subject to the following conditions:
7 Findings:
That the requested use is necessary or desirable for the development of the community, is
essentially in harmony with the various elements and objectives of the General Plan, and
is not detrimental to existing uses specifically permitted in the zone in which the
10 proposed use is located, in that: (1) the proposed expansion to the telephone electronic
switching facility will ensure that telephone service is available for new growth in
11 the City; (2) the proposed telephone electronic switching facility is consistent with
General Plan policies related to industrial uses; and, (3) the proposed project has
been designed with comparable architecture and enhanced landscaping.
13 2. That the site for the intended use is adequate in size and shape to accommodate the use, in
14 that only 26% of the site will be covered with a structure and the site has been
designed with adequate setbacks, parking and enhanced landscaping.
15
. That all the yards, setbacks, walls, fences, landscaping, and other features necessary to
adjust the requested use to existing or permitted future uses in the neighborhood will be
provided and maintained, in that the proposed project meets all development
standards of the PM zone and the site has been conditioned to provide and maintain
18 adequate landscaping on the site.
4. That the street system serving the proposed use is adequate to properly handle all traffic
generated by the proposed use, in that the traffic impacts of the telephone electronic
switching facility amount to approximately 32 trips per day and Camino Vida
21 Roble, a secondary arterial, is adequate in size to accommodate the vehicle trips
generated by the project.
22
The project is consistent with the City-Wide Facilities and Improvements Plan, the Local
23 Facilities Management Plan for Zone 5 and all City public facility policies and
24 ordinances. The project includes elements or has been conditioned to construct or
provide funding to ensure that all facilities and improvements regarding: sewer collection
25 and treatment; water; drainage; circulation; fire; schools; parks and other recreational
facilities; libraries; government administrative facilities; and open space, related to the
26 project will be installed to serve new development prior to or concurrent with need.
Specifically,
2g A. The project has been conditioned to provide proof from the Carlsbad Unified
School District that the project has satisfied its obligation for school facilities.
PC RESO NO. 4923 -2-
B. The Public Facility fee is required to be paid by Council Policy No. 17 and will be
2 collected prior to the issuance of building permit.
3 C. The Park Facilities impact fee for Zone 5 is required by Carlsbad Municipal Code
21.90.050 and will be collected prior to the issuance of building permits.
4
D. The Local Facilities Management fee for Zone 5 is required by Carlsbad
Municipal Code Section 21.90.050 and will be collected prior to issuance of
building permit.
6. The project is consistent with the Comprehensive Land Use Plan (CLUP) for the
McClellan-Palomar Airport, dated April 1994, in that the project has recorded a notice
concerning aircraft noise. The project is compatible with the projected noise levels of
the CLUP; and, based on the noise/land use compatibility matrix of the CLUP, the
proposed land use is compatible with the airport, in that the telephone electronic
10 switching facility is identified as a compatible use in the CLUP.
11 7. That the project is consistent with the City's Landscape Manual (Carlsbad Municipal
Code Section 14.28.020 and Landscape Manual Section I B).
to 8. AH findings of Planning Commission Resolutions No. 3666 and 3960 relating to CUP
154(A) and CUP 154(C) apply to this conditional use permit and are incorporated
14 herein by reference.
15 9. The Planning Commission has reviewed each of the exactions imposed on the Developer
contained in this resolution, and hereby finds, in this case, that the exactions are imposed
to mitigate impacts caused by or reasonably related to the project, and the extent and the
17 degree of the exaction is in rough proportionality to the impact caused by the project.
18 Conditions:
7ft
Note: Unless otherwise specified herein, all conditions shall be satisfied prior to Grading
Permit Issuance.
21 1. If any of the following conditions fail to occur; or if they are, by their terms, to be
implemented and maintained over time, if any of such conditions fail to be so
22 implemented and maintained according to their terms, the City shall have the right to
revoke or modify all approvals herein granted; deny or further condition issuance of all
" future building permits; deny, revoke or further condition all certificates of occupancy
24 issued under the authority of approvals herein granted; institute and prosecute litigation to
compel their compliance with said conditions or seek damages for their violation. No
25 vested rights are gained by Developer or a successor in interest by the City's approval of
this Conditional Use Permit
26
. Staff is authorized and directed to make, or require the Developer to make, all corrections
and modifications to the Conditional Use Permit documents, as necessary to make them
internally consistent and in conformity with the final action on the project. Development
shall occur substantially as shown on the approved Exhibits. Any proposed development
different from this approval, shall require an amendment to this approval.
PC RESO NO. 4923 -3-
1
2 3. The Developer shall comply with all applicable provisions of federal, state, and local
laws and regulations in effect at the time of building permit issuance.
3
4. If any condition for construction of any public improvements or facilities, or the payment
of any fees in-lieu thereof, imposed by this approval or imposed by law on this Project
are challenged, this approval shall be suspended as provided in Government Code Section
66020. If any such condition is determined to be invalid this approval shall be invalid
unless the City Council determines that the project without the condition complies with
all requirements of law.
5. The Developer/Operator shall and does hereby agree to indemnify, protect, defend and
hold harmless the City of Carlsbad, its Council members, officers, employees, agents, and
representatives, from and against any and all liabilities, losses, damages, demands, claims
and costs, including court costs and attorney's fees incurred by the City arising, directly
10 or indirectly, from (a) City's approval and issuance of this Conditional Use Permit, (b)
City's approval or issuance of any permit or action, whether discretionary or non-
11 discretionary, in connection with the use contemplated herein, and (c)
Developer/Operator's installation and operation of the facility permitted hereby,
including without limitation, any and all liabilities arising from the emission by the
facility of electromagnetic fields or other energy waves or emissions.
14 6. The Developer shall submit to the Planning Department a reproducible 24" x 36",
mylar copy of the Site Plan reflecting the conditions approved by the final decision
15 making body.
7. The Developer shall include, as part of the plans submitted for any permit plan check, a
17 reduced legible version of all approving resolution(s) in a 24" x 36" blueline drawing
format.
18
8. Prior to the issuance of a building permit, the Developer shall provide proof to the
Director from the School District that this project has satisfied its obligation to provide
school facilities.
21 9. This project shall comply with all conditions and mitigation measures which are required
as part of the Zone 5 Local Facilities Management Plan and any amendments made to
22 that Plan prior to the issuance of building permits, including but not limited to the
following:23 &
24 10. The developer shall pay a Local Facilities Management Plan park Fee of $.40 per square
foot of non-residential development to be collected at the time of building permit
25 issuance.
26 11, This approval is granted subject to the approval of the Negative Declaration and
Hillside Development Permit and is subject to all conditions contained in Planning
Commission Resolution No. 4924 for those other approvals.
28 12. The existing use on site (telephone electronic switching facility) was approved under
Conditional Use Permits CUP 154(A) and CUP 154(C), Planning Commission
PC RESO NO. 4923 -4-
Resolutions No. 3666 and 3960. All conditions of the previously approved project
2 (CUP 154(C), Resolution No. 3960) are superseded by Planning Commission
Resolution No. 4923. All conditions of approval for CUP 154(A), Planning
3 Commission Resolution No. 3666 were superseded by CUP 154(C), Planning
Commission Resolution No. 3960, when CUP 154(C) was approved.
4
13. This Conditional Use Permit shall be reviewed by the Planning Director on a yearly basis
to determine if all conditions of this permit have been met and that the use does not have
5 a substantial negative effect on surrounding properties or the public health and welfare. If
the Planning Director determines that the use has such substantial negative effects, the
7 Planning Director shall recommend that the Planning Commission, after providing the
permittee the opportunity to be heard, add additional conditions to reduce or eliminate the
substantial negative effects.
9 14. This Conditional Use Permit is granted for a period of 10 years from February 21, 2001
10 through February 21, 2011. This permit may be revoked at any time after a public
hearing, if it is found that the use has a substantial detrimental effect on surrounding land
11 uses and the public's health and welfare, or the conditions imposed herein have not been
met. This permit may be extended for a reasonable period of time not to exceed 10 years
upon written application of the permittee made no less than 90 days prior to the
expiration date. The Planning Commission may not grant such extension, unless it finds
that there are no substantial negative effects on surrounding land uses or the public's
14 health and welfare. If a substantial negative effect on surrounding land uses or the
public's health and welfare is found, the extension shall be denied or granted with
15 conditions which will eliminate or substantially reduce such effects. There is no limit to
1 the number of extensions the Planning Commission may grant.16
17 15. Approval is granted for CUP 154(D) as shown on Exhibits "A" - "L", dated February
21, 2001, on file in the Planning Department and incorporated herein by reference.
18 Development shall occur substantially as shown unless otherwise noted in these
conditions.
19
16. The Developer is aware that the City is preparing a non-residential housing impact fee
(linkage fee) consistent with Program 4.1 of the Housing Element. The applicant is
21 further aware that the City may determine that certain non-residential projects may have
to pay a linkage fee, in order to be found consistent with the Housing Element of the
22 General Plan. If a linkage fee is established by City Council ordinance and/or resolution
and this project becomes subject to a linkage fee pursuant to said ordinance and/or
resolution, then the Developer, or his/her/their successors) in interest shall pay the
24 linkage fee. The linkage fee shall be paid at the time of issuance of building permits,
except for projects involving a request for a non-residential planned development for an
25 existing development, in which case, the fee shall be paid on approval of the final map,
parcel map or certificate of compliance, required to process the non-residential PUD,
26 whichever pertains. If linkage fees are required for this project, and they are not paid, this
project will not be consistent with the General Plan and approval for this project will
become null and void.
28 17. The Developer shall submit and obtain Planning Director approval of a Final Landscape
and Irrigation Plan showing conformance with the approved Preliminary Landscape Plan
PC RESO NO. 4923 -5-
and the City's Landscape Manual. The Developer shall construct and install all
2 landscaping as shown on the approved Final Plans, and maintain all landscaping in a
healthy and thriving condition, free from weeds, trash, and debris.
3
18. The first submittal of Final Landscape and Irrigation Plans shall be pursuant to the
landscape plan check process on file in the Planning Department and accompanied by the
project's building, improvement, and grading plans.
5 19. Prior to the issuance of the building permit, Developer shall submit to the City a Notice
of Restriction to be filed in the office of the County Recorder, subject to the satisfaction
7 of the Planning Director, notifying all interested parties and successors in interest that the
City of Carlsbad has issued a Conditional Use Permit by Resolutions No. 4923 on the
real property owned by the Developer. Said Notice of Restriction shall note the property
description, location of the file containing complete project details and all conditions of
approval as well as any conditions or restrictions specified for inclusion in the Notice of
10 Restriction. Tbe Planning Director has the authority to execute and record an amendment
to the notice which modifies or terminates said notice upon a showing of good cause by
11 the Developer or successor in interest.
17 20. No outdoor storage of materials shall occur onsite unless required by the Fire Chief.
When so required, the Developer shall submit and obtain approval of the Fire Chief and
the Planning Director of an Outdoor Storage Plan, and thereafter comply with the
14 approved plan.
15 21. All roof appurtenances, including air conditioners, shall be architecturally integrated and
concealed from view and the sound buffered from adjacent properties and streets, in
substance as provided in Building Department Policy No. 80-6, to the satisfaction of the
17 Directors of Community Development and Planning.
18 22. The Developer shall submit and obtain Planning Director approval of an exterior lighting
plan including parking areas. All lighting shall be designed to reflect downward and
avoid any impacts on adjacent homes or property.
20 23. The minimum front yard setback for buildings and parking spaces shall be 65 feet
2i as measured from the right-of-way line of Camino Vida Roble. This setback shall
be entirely landscaped and irrigated.
22
Engineering23
24 General
25 24. Prior to hauling dirt or construction materials to or from any proposed construction site
within this project, Developer shall apply for and obtain approval from, the City Engineer
26 for the proposed haul route.
97 25. Prior to issuance of any building permit, Developer shall comply with the requirements of
the City's anti-graffiti program for wall treatments if and when such a program is
formally established by the City.
PC RESO NO. 4923 -6-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Prior to the issuance of grading permit or building permit, whichever occurs first, the
applicant shall submit for City approval a "Storm Water Pollution Prevention Plan
(SWPPP)". The SWPPP shall be in compliance with current requirements and provisions
established by the San Diego Region of the California Regional Water Quality Control
Board. The SWPPP shall address measures to reduce to the maximum extent possible
storm water pollutant runoff at both construction and post-construction phases of the
project. At a minimum, the Plan shall:
A) Identify existing and post-development on-site pollutants.
B) Recommend source control Best Management Practices (BMPs) to filter said
pollutants.
C) Establish specific procedures for handling spills and routine clean up.
D) Special considerations and effort shall be applied to employee education on the
proper procedures for handling clean up and disposal of pollutants.
E) Ensure long-term maintenance of all post construct BMPs in perpetuity.
F) Identify how post-development runoff rates and velocities from the site will not
exceed the pre-development runoff rates and velocities. If maintaining post-
development rates at pre-development levels cannot be achieved, adequate
justification subject to the City Engineer's approval must be provided.
Fees/Agreements
27. Developer shall cause property owner to execute and submit to the City Engineer for
recordation the City's standard form Drainage Hold Harmless Agreement regarding
drainage across the adjacent property.
Grading
28. Prior to the issuance of a grading permit or building permit, whichever occurs first,
Developer shall submit to the City Engineer proof that a Notice of Intention for the start
of work has been submitted to the State Water Resources Control Board.
29. Based upon a review of the proposed grading and the grading quantities shown on the site
plan, a grading permit for this project is required. Developer shall apply for and obtain a
grading permit from the City Engineer prior to issuance of a building permit for the
project.
Dedications/Improvements
Developer shall cause Owner to make an irrevocable offer of dedication to the City
and/or other appropriate entities for all public streets (5 foot dedication of property
frontage for public right-of-way) and other easements (water easement for onsite fire
hydrant and water main) shown on the site plan. The offer shall be made by separate
recorded documents. All land so offered shall be offered free and clear of all liens and
encumbrances and without cost. Streets that are already public are not required to be
rededicated.
The developer shall process improvement plans through the City for the relocation
of the on-site water line and fire hydrant and installation of sidewalk. The plans
PC RESO NO. 4923 -7-
must be processed and approved by the City Engineer prior to the issuance of a
2 building permit. The sidewalk must also be installed prior to the issuance of a
building permit unless cash in an amount satisfactory to the City Engineer is
3 submitted to the City as collateral to secure the sidewalk installation.
Water/Sewer/Recycled Water
32. The Developer shall design and construct public facilities within public right-of-way or
within minimum 20-foot wide easements granted to the District or the City of Carlsbad.
At the discretion of the Deputy City Engineer - Utilities, wider easements may be
required for adequate maintenance, access and/or joint utility purposes.
8
33. This project is approved upon the express condition that building permits will not be
issued for the development of the subject property, unless the Deputy City Engineer -
10 Utilities has determined that adequate water and sewer facilities are available at the time
ofoccupancy.11
The sewer cleanout located within the driveway shall be protected by a concrete box
12 — and traffic lid per Dwg. No. 7 of the "Carlsbad Municipal Water District Standard
. - Drawings for Sewer
14 Standard Code Reminders
15 The project is subject to all applicable provisions of local ordinances, including but not limited to
the following:
17 35. Developer shall exercise special care during the construction phase of this project to
prevent offsite siltation. Planting and erosion control shall be provided in accordance
18 with Carlsbad Municipal Code Chapter 15.16 (the Grading Ordinance) to the satisfaction
of the City Engineer.
19
36. Developer shall pay the citywide Public Facilities Fee imposed by City Council Policy
#17, the License Tax on new construction imposed by Carlsbad Municipal Code Section
5.09.030, and CFD #1 special tax (if applicable), subject to any credits authorized by
Carlsbad Municipal Code Section 5.09.040. Developer shall also pay any applicable
22 Local Facilities Management Plan fee for Zone 5 pursuant to Chapter 21.90. All such
taxes/fees shall be paid at issuance of building permit. If the taxes/fees are not paid, this
approval will not be consistent with the General Plan and shall become void.
24 37. The Developer shall pay a landscape plan check and inspection fee as required by Section
25 20.08.050 of the Carlsbad Municipal Code.
26 38. Approval of this request shall not excuse compliance with all applicable sections of the
Zoning Ordinance and all other applicable City ordinances in effect at time of building
27 permit issuance, except as otherwise specifically provided herein.
28 39. The project shall comply with the latest non-residential disabled access requirements
pursuant to Title 24 of the State Building Code.
PC RESO NO. 4923 -8-
1
2 40. Any signs proposed for this development shall at a minimum be designed in conformance
with the City's Sign Ordinance and shall require review and approval of the Planning
3 Director prior to installation of such signs.
4 NOTICE
5 ..
Please take NOTICE that approval of your project includes the "imposition" of fees,
6 dedications, reservations, or other exactions hereafter collectively referred to for convenience as
"fees/exactions."7
You have 90 days from date of final approval to protest imposition of these fees/exactions. If
you protest them, you must follow the protest procedure set forth in Government Code Section
66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely
follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or
annul their imposition.
12 You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions
DOES NOT APPLY to water and sewer connection fees and capacity charges, nor planning,
13 zoning, grading or other similar application processing or service fees in connection with this
project; NOR DOES IT APPLY to any fees/exactions of which you have previously been given
a NOTICE similar to this, or as to which the statute of limitations has previously otherwise
-. expired.
16
17
18
19
20
21
22
23
24
25
26
27
28
PCRESONO.4923 -9-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
PASSED, APPROVED AND ADOPTED at a regular meeting of the Planning
Commission of the City of Carlsbad, California, held on the 21st day of February 2001 by the
following vote, to wit:
AYES:
NOES:
Chairperson Segall, Commissioners Baker, Compas, Heineman,
Nielsen, and Trigas
ABSENT: Commissioner L'Heureux
ABSTAIN:
JEF¥KEN. SEGALL^feairperson
CARLSBAD PLANNING COMMISSION
ATTEST:
MICHAEL j
Planning Director
PC RESO NO. 4923 -10-
M J
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB £>/ -
Planner Van Lynch
APN: ^Cl
Address
Phone (760) 602-4613
Type of Project & Use:.
Zoning: £?JT.
(in/oljtj) # -
CircTe-Qrie
General Plan:
_Net Project Density: ,
Facilities Management Zone:
DU/AC
Date of participation:Remaining net dev acres:
(For non-residential development: Type of land used created by
this permit: )
Legend:Item Complete
Environmental Review Required:
DATE OF COMPLETION: /O-ll-OO
Item Incomplete - Needs your action
YES X NO TYPE /A£X
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval: /V-A
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
YES NO TYPE
DATE
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: fTf^T^^^ **Yi*fc 9/rfrfrA/J &) £A**A5CAf>tr
70
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES
CA Coastal Commission Authority? YES
NOX
NO
If California Coastal Commission Authority: Contact them at - California Coastal Commission
San Diego District, 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402, Phone: 619-
767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES NO
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
1} Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
Inclusionary Housing Fee required: YES
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
NO )C
Data Entry Completed? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!)
t
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number.
, Zoning:
^ 1 . Setbacks:
Front:
Interior Side:
Street Side:
Rear:
_^ 2. Accessory structure
Front:
Interior Side:
Street Side:
Rear:
Structure separation
K 3. Lot Coverage:
Required /^_T
Required lOf
Required ~-~
Required /£>'
setbacks:
Required
Required A/ /
Required " / f\
Required ' /~l
: Required
Required , ^ %& *J&T~
Shown <-?~?f
Shown £J~'
Shown — — •
Shown 3^V*
Shown
Shown
Shown
Shown
Shown
Shown 2" ($ *fe
4. Height:Required Shown JT
5. Parking: Spaces Required 3 £—
Guest Spaces Required
Additional Comments
Shown
Shown
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
Carlsbad Fire DeDartment 010586
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report: 07/11/2001
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by:
Name:
Address:
Rick Lien
P O Box 930
City, State: Poway CA 92074
Plan Checker:
Job Name: Pacific Bell
Job#: 010586
Job Address: 2175 Camino Vida Roble
I | Approved
Bldg #: CB010586
Ste. or Bldg. No.
The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in yoursubmittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review
FD Job #
1 st ?nf1 3rri
010586 FDFile#
Othfir Agenny ID
Carlsbad Fire Department 010586
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report: 07/11/2001
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by:
Name:
Address:
Rick Lien
P O Box 930
City, State: Poway CA 92074
Plan Checker:
Job Name: Pacific Bell
Job#: 010586
Job Address: 2175 Camino Vida Roble
Bldg #: CB010586
Ste. or Bldg. No.
u Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review
FD Job #
1 fit ?n/-i 3rd
010586 FDFile#
Other Agency ID
Requirements Category: Building Plan
Requirement: Pending 05.15 Automatic Fire Sprinkler System Required
A fire sprinkler system is required for this building. If the building is a spec building (no tenant
known) the sprinkler system must be designed to .45/3000. Provide notes on the plans that fire
sprinkler plans will be submitted to the fire department for approval prior to installation.
Requirement: Pending 05.32 Additional Requirements or Comments
Handicap parking cannot block backflow preventer and fire department connection.
Provide the fire department with a copy of the technical report.
Paget 07/11/01
Carlsbad Fire Department 010586
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report: 02/22/2001
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by:
Name:
Address:
Rick Lien
P O Box 930
City, State: P°way CA 92074
Plan Checker:
Job Name: Pacific Bell
Job#: 010586
Job Address: 2175 Camino Vida Roble
Bldg#: CB010586
Ste. orBldg. No.
D Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review
FD Job #
1st 2nd 3rd
010586 FDFile*
Other Aqencv ID
Requirements Category: Building Plan
Requirement: Pending 05.15 Automatic Fire Sprinkler System Required
A fire sprinkler system is required for this building. If the building is a spec building (no tenant
known) the sprinkler system must be designed to .45/3000. Provide notes on the plans that fire
sprinkler plans will be submitted to the fire department for approval prior to installation.
Requirement: Pending 05.32 Additional Requirements or Comments
Handicap parking cannot block backfiow preventer and fire department connection.
Page 1 02/22/01