HomeMy WebLinkAbout2175 Camino Vida Roble; ; CBC2018-0180; Permit(city of
Carlsbad
Commercial Permit
Print Date: 08/28/2018 Permit No: CBC2018-0180
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
2175 Camino Vida Roble
BLDG-Commercial
2130501300
$80,000.00
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Tenant Improvement Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Closed -Finaled
04/03/2018
06/11/2018
PBurn
Plan Check#:
Final
Inspection: 8/28/2018 9:34:28AM
Project Title:
Description: AT&T: AODING A WASTE MANAGEMENT SYSTEM, ICE MACHINE AND LOCKERS
Owner: Contractor:
PACIFIC BELL RJ DAUM CONSTRUCTION COMPANY
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
2175 Camino Vida Roble
CARLSBAD, CA 92008
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
MECHANICAL BLOG COMMERCIAL NEW/AODITION/REMODEL
PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $1,118.53 Total Payments To Date: $1,118.53
7562 Trade St
San Diego, CA 92121-2412
858-621-8750
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions bereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$538.90
$377.23
$60.00
$4S.OO
$71.00
$4.00
$22.40
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING 0BUILD1NG OFIRE OHEALTH 0HAZMAT/APCD
( City of
Carlsbad
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITE#/SPACE#/UNIT# JOB ADDRESS 2175 Camino Vida Roble
Plan Check No.
Est. Value
Date SWPPP
24 00
CT/PROJECT# LOT# PHASE# # OF UNITS # BEDROOMS # BATHROOMS CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK: Jnclude Square Feet of Affected Area(s)
Adding a waste management system, ice machine and lockers.
EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) I FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS
Telephone Exchange no change YES[), No0 YES0No0 YES0No0
APPLICANT NAME Marie Lakev PROPERTY OWNER NAME AT&T California Prlmano Contact
ADDRESS ADDRESS 4719 Palm Ave 650 Robinson Ave
CITY STATE ZIP CITY STATE ZIP La Mesa CA 91941 San Diego CA 92103
PHONE
'FAX
PHONE FAX
6194666224
EMAIL EMAIL
mlakey@treisd.com nv3624t@att.com
DESIGN PROFESSIONAL Turoin & Rattan Enaineerina, Inc. CONTRACTOR BUS. NAME RJ Daum Construction
ADDRESS ADDRESS
4719 Palm Ave 7562 Trade Street
CITY STATE ZIP CITY STATE ZIP
La Mesa CA 91941 San Dieao CA 92121
PHONE 'FAX PHONE FAX
6194666224 8586218750
EMAIL EMAIL
mlakey@treisd.com tpike®ridaum.com I STATE UC. '19334 STATE LIC.# i'l. 7160 ~~~ C-8' 1 c,e'.'i'.'.'.os, Z-Vi<' 1 1 '><
(Sec. 7031.5 Business and Professions Code: Any City or Coun.ty which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, comme.nding with Section 7000 of Division 3 of the B.usiness and Professions Code} or that he 1s exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars ($500}).
WORKERS' COMPENSATION
Wortc:ers' Compensation Declaration: / hereby affimi under penalty of petju,y one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ I have and wm m,;.1a;o worl<e<}Jompeos~on, as ,equ;~d by Secboo 3700 of the Labo, Code. foe the pertocmaace of the •o_rk for which lhs permit is issued. My workers' compensati(J\i'}>ur-ance carrier and policy
""mbec '"' lasoraace Co _ eW ~ ~.re ;\: 1'\VI t.w-~ Co"'~po1;cy No. _ '2. l Z %'J'il_ ___ ---Exp;,at;on Date _'.I/ j,'ly____ ---_
'pi.is. section need not be completed if the permit is for one hundred dollars ($100) or less.
LJ Certificate of Exemption: l certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure ta secure wartc:ers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, d provided for tn .~ectlon 3706 of the Labor code, interest and attorney's fees.
LS CONTRACTOR SIGNATURE t8/'GENT DATE !JiAVIC'
I hereby affirm that I am e:tempt from Contractor's License Law for the following reason:
0
0
D
I, as owner of the property or my employees with wages as their sole corrl)ensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and Who does such work himself or through his own employees, provided that such improvements are not inlended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who bu11ds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section ___ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement 0Yes 0No
2. I (have I have not) signed an application for a building permit for the proposed work
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work {include name I address I phone I contractors' license number):
5. I wilt provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
LS PROPERTY OWNER SIGNATURE O•GENT DATE
COMPLETE THIS SECTION FOR NON·RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? Yes No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management distn'ct? Yes No
\s the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the application and state that the abo\le infonnat:ion is correct and that the infonnatlon on the plans is accurate. I agree to comply'Mth all City ordinances and State laws relating to building construction.
I hereby authoriZe representative of the City of Cartsbad to enter upon the above mentioned property for inspectiofl purposes, I /IJ..SO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE Of THE GRANTING OF THIS PERMIT.
OSHA: AA OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every pelTllil issued by the Building Official un<iar the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the dale of such permit or if the budding or WOik aulhonzed by such permit IS sjpended or abandoned at any time after the wol1<.1S commenced fOI" a period of 180 days {Section 106 4 4 Unifom1 Bu1ld1ng Code}
-@fAPPLICANT'SSIGNATURE _/}---~ DATE ~-Zb -_\!!r
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email bµilding@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
~DD RESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE I FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
PICKUP: CONTACT (Listed abo'tle) OCCUPANT (Listed abo'tle)
CONTRACTOR (On Pg. 1)
ASSOCIATED CB#-·--·-----·--.--.---MAIL TO: CONTACT (Listed abo..,e} OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION
MAIL/ FAX TO OTHER: --·---·--··· -. CHANGE OF USE / NO CONSTRUCTION
·-·-
.6SAPPLICANT'S SIGNATURE DATE
' ,,
a PERMIT INSPECTION HISTORY REPORT (CBC2018-0180)
Permit Type: BLDG-Commercial Application Date: 04/03/2018
Work Class: Tenant Improvement Issue Dato: 06/11/2018
Status: Closed -Finaled E.xpiration Date: 12/10/2018
Scheduled
Date
06/06/2018
Actual
Start Date
06/06/2018
06/12/2018 06/12/2018
08/28/2018 08/28/2018
August 28, 2018
IVR Nurnber: 10501
Inspection Type Inspection No.
BLDG-24
Rough!Topout
060175-2018
Checklist Item
BLDG-Building Deficiency
BLDG-11
Foundatlon/Ftg/Pier
s (Rebar)
060708-2018
BLDG-Final
Inspection
Checklist Item
BLOG-Building Deficiency
068329-2018
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Inspection Status
Passed
COMMENTS
Passed
COMMENTS
Passed
COMMENTS
Owner: PACIFIC BELL
Subdivision: CARLSBAD TCT#73-49
Address: 2175 Camino Vida Roble
Carlsbad, CA 92011-1404
Primary Inspector Reinspection
Paul Burnette
Passed
Yes
Paul Burnette
Passed
Yes
Andy Krogh
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Complete
Complete
Page 1 of 1
Job Address
Eagle Special Inspections, Inc
ACI-ICC
PO Box 2276, Vista, CA 92085
(760) 716-0244
Email: mdutemple@gmail.com
DAILY OBSERVATION REPORT
2175 Camino Vida Roble rennit No. CBC2018= 1080
Job Name Storage Container ·Plan File No. issoed by Carlsbad
Architect Turpin & Rattan
Contractor RJ Daum
Material_ Reinforcement Dcscnpbon
DESCRIPTION OF WORK OBSERVED
;Engineer Lane
. Subcontractor Ang us
' :samples ,, X ,, Qty
DATE: 6/12/2018
Observation of concrete placement for new footings for storage container. Reinforcement in place
per 21, 32, 11 / S0.1. Bar size, spacing, quantity, laps and clearance verified.
I hereby certify, that at the time of this report, I have observed all of the Inspector Michael DuTemoK("" ) above reported work, unless otherwise noted. To the best of my knowledge
and belief, I have found this work to comply with the approved plans, ~ --specifications and applicable sections of the building code as it applies to Signature 7 the jurisdiction where the project is localed. This report cannot be construed
to be a recommendation of work, of any nature, to be performed. The -
Owner, or a successor in interest, shall hold hannless Eagle Special Concrete ICC 8206178 Inspections, Inc from any and all legal proceedings, of any nature
whatsoever, that are related to the observation services provided. Specialty License No.
TIME rN TIME OUT I MrN FEE IDAIL y FEEi OT HRS I DTHRS
4 Approved By:
'
I
/
I
i
Eagle Special Inspections, Inc
ACI-ICC
PO Box 2276, Vista, CA 92085
(760) 716-0244
Email: mdutemple@gmail.com
DAILY OBSERVATION REPORT
JobAddcess 2175 Camino Vida Roble Pecmll No CBC2018':;J.G60 0/'t,O
Joh Name Storage Container Plan File No Issued by Carlsbad
Acch;tect Turpin & Rattan Engineer Lane
Contractor RJ Daum Subcontractor Angus
Material Reinforcement Samples "X " Qty Description
DESCRIPTION OF WORK OBSERVED DATE· 6/12/2018
Observation of concrete placement for new footings for storage container. Reinforcement in place
per 21, 32, 11 I S0.1. Bar size, spacing, quantity, laps and clearance verified.
I hereby certify, that at the time of this report, I have observed all of the lnspecto1· Michael DuTemoll("'"" ) above n:porteJ work, unless otherwise noted. To the best ofmy knowledge
and belief. I have found this work to comply wilh the approved plans, -"' -specifications and applicable sections of the building code as it applies to t' the jurisdiction wher1.: the proJect is located This reporl cannot be construed Signature ../'
to be a recommendation of work, of any nature, to be performed. The -
Owner, or a successor in interest, shall hold harmless [agle Special Concrete ICC 8206178 Inspections, Inc from any and all legal proceedings, of any nature
whatsoever, that are related to the observation services provided Specialty License No
TIMFIN TIME OUT I MIN FEE DAILY FEEi OT HRS I OT HRS
14 Appmved By:
;
I
!
I
Eagle Special Inspections, Inc
AC! -ICC
PO Box 2276, Vista, CA 92085
(760) 716-0244
Email: mdutemple@gmail.com
DAILY OBSERVATION REPORT
Job Addcess 2175 Camino Vida Roble Pecmit No CBC2018=1080
Job Name Storage Container Plan File No. Issued by
Acchitect Turpin & Rattan Engineer Lane
Contractor RJ Daum Subcontractor Angus
Material C t Description 0ncre e Samples 4 "X 8
DESCRIPTION OF WORK OBSERVED DATE: 6/13/2018
Carlsbad
" Qty 4
Observation of concrete placement for new footings for storage container. Reinforcement in place
per 21, 32, 11 I S0.1. Bar size, spacing, quantity, laps and clearance verified. Superior mix
#8258P 3000 psi concrete was tailgated into clean, dry, debris free earthen forms and manually
consolidated. 4 yds placed
Concrete 82' Air 73' Slump 5" Ticket #2387735 0 gallons added
I hereby certify, that at the time of this report, I have observed all of the [nspector Michael DuTemoi€"'"" ) above reported work, unless otherwise noted. To the best of my knowledge
and belief, I have found this work to comply with the approved plans, ,JI('\. -specifications and applicable sections of the building code as it applies to r the jurisdiction where the project 1s located. This report cannot be construed Signature _.,,
to be a recommendation of work, of any nature, Lo be pertOnned The -
Owner, or a successor in interest, shall hold harmless Eagle Spec ml Concrete ICC 8206178 Inspections, Inc from any and all legal proceedings, of any nature
whatsoever, that are related to the observation services provided. Specialty License No
TIME IN TIMEOUT MIN FEE DAILY FEE\ OTHRS I DTHRS
4 Approved By:
'
I
j
I
Eagle Special Inspections, Inc
ACT-ICC
PO Box 2276, Vista, CA 92085
(760) 716-0244
Email: mdutemple@gmail.com
DAILY OBSERVATION REPORT
Job Add<ess 2175 Camino Vida Roble Pe,m;, No CBC2018=1080
Job Name Storage Container Plan File No Issued by
M,h;iect Turpin & Rattan Engineer Lane
Contractor RJ Daum Subcontractor TC
Mate,;,1 W Id"
Description e lnQ Samples "X
DESCRIPTION OF WORK OBSERVED DATE: 7/12/2018
Carlsbad
" Qty
Observation of field welding for embed plates to new storage container. Fillet Welds in place
per 31/S0.1. Size and type in conformance to approved plans
I hereby certify, that at the time of this report, I have observed all of the Inspector Michael DuTemt)il("" } above reported work, unless otherwise noted. To the best of my knowledge
and belief, I have found this work to comply with the approved plans, ,Al('\ ~
specifications and applicable sections of the building code as it applies to r the jurisdiction where the project is located. This report cannot be construed Signature ~
to be a recommendation of work, of any nature, to be performed. The -
Owner, or a successor in interest, shall hold harmless Eagle Special Concrete ICC 8206178 Inspections, Inc from any and all legal proceedings, of any nature
whatsoever, that are related to the observation services provided Specialty License No.
TIME IN TIMEOUT MIN FEE DAILY FEE! OT HRS I DT HRS
4 ' Approved By:
i
I
'
'
I
City of Carlsbad CBC2018-180
5/17/2018
~ EsG1I
A SAH:bu1lt Cornp,iny
DATE: 5/17/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-180 SET: II
il-APPLICANT r JURIS.
PROJECT ADDRESS: 2175 Camino Vida Roble
PROJECT NAME: AT&T adding waste management system, Ice machine and
lockers
D
D
D
D
D
The plans transmitted herewith have been corrected where necessary and
substantially comply with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the
enclosed check list and should be corrected and resubmitted for a complete
recheck.
The check list transmitted herewith is for your information. The plans are being
held at EsGil until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to
the applicant contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: (),
Date contacted: /./
Telephone#:
(b~ Email:
Mail Telephone Fax In Person
D REMARKS:
By: Morteza Beheshti
EsGil
5/10
Enclosures:
•
DATE: 4/13/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-180
~ EsG1I
A SAf'Ebu1\t Co1npar,y
SET: I
PROJECT ADDRESS: 2175 Camino Vida Roble
D APPLICANT
D JURIS.
PROJECT NAME: AT&T adding waste management system, Ice machine and lockers
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:,rarie Lakey Telephone#: 619.466:~~ (I) 2 Zt/
Date contacted: '1";l{Q (by(@ ) Email: mlakey@treisd.com
Mail Telephone Fax In Person
D REMARKS:
By: Morteza Bebeshti
EsGil
4/5
Enclosures:
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad CBC2018-180
4/13/2018
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK#.: CBC2018-180
OCCUPANCY: B
TYPE OF CONSTRUCTION: V
ALLOWABLE FLOOR AREA:
SPRINKLERS?:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 1/16/18
DATE INITIAL PLAN REVIEW
COMPLETED: 4/13/2018
FOREWORD (PLEASE READ):
JURISDICTION: City of Carlsbad
USE: Corporate real estate
ACTUAL AREA:
STORIES: 1
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/5
PLAN REVIEWER: Morteza Beheshti
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBC2018-180
4/13/2018
Please make all corrections on the original tracings, as requested in the correction
list. Submit four sets of plans for commercial/industrial projects (three sets of
plans for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring two corrected sets of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. Please sign all plans.
2. Please GFI receptacle for the ice machine. Depending on age of the machine.
3. Please provide pipe size for the drain pipe. P trap not shown for connection to
building sewer.
4. Please provide lighting energy compliance forms for review.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes D No D
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Morteza Beheshti
at Esgil Corporation. Thank you.
• 'City of Carlsbad CBC2018-180
4/13/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK#.: CBC2018-180
PREPARED BY: Morteza Beheshti DATE: 4/13/2018
BUILDING ADDRESS: 2175 Camino Vida Roble
BUILDING OCCUPANCY: M
BUILDING AREA Valuation
PORTION (Sq.Ft.) Multiplier
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1997 UBC Building Permit Fee
1997 UBC Plan Check Fee
Type of Review: 0 Complete Review
D Repetitive Fee -... .,;.J Repeats
Comments:
D Other
D Hourly
EsGil Fee
Reg. VALUE
Mod.
138,414
D Structural Only
1-------11Hr. @ •
($)
80,000
80,000
$534.00!
$347.10J
$304.38J
Sheet 1 of 1
LANE ENGINEERS, INC.
979 N. Blackstone St.
Tulare, CA 93274
Phone: (559) 688-5263
www .Ianeengineers.com
Date: March 81h, 2018
CLIENT: Turpin & Rattan, Inc.
Sheet: I of G
Appendix: A-I -> ~
Job No. 18061
PROJECT:
LOCATION:
20' Storage Container Anchorage and Footings for AT&T Recycle Center
2175 Camino Vida Roble
Carlsbad, CA
GOVERNING CODE: California Building Code, 2016 Edition
STRUCTURAL CALCULATIONS ARE BASED ON THE FOLLOWING CRITERIA,
UNLESS NOTED OTHERWISE
Risk Category.... ......................... ............ . .............................. Risk Category II
Wind Loading............................ .............. . ...... 110 MPH (3-sec Gust), Exp. C
Seismic Loading_........................................... . ........... Design Category D
Design Methodology......... ............ ............... . . .... Allowable Stress Design
Structural Steel (shapes, plates, barsL.......... . ....... ASTM A36 or A572 (36 ksi yield)
Cold-Formed (light-gage) sections, plates, etc.:
16 Ga. & Heavier
18 Ga. & Lighter ....................... .
Pipe ................................ .
Rectangular Hollow Structural Steel. ...... .
Welding .................................................. .
Bolts
Reinforcing Steel (#4 & smallerL ........ .
Reinforcing Steel (#5 and larger) ......... .
Concrete ..
Soil Bearing ..
... ASTM A570 (50 ksi yield)
.... ASTM A61 I, Gr. C (33 ksi yield)
ASTM A53, Gr. B (35 ksi yield)
ASTM A500, Gr. B ( 46 ksi yield)
AWA D\.1-06
ASTMA307
. ... ASTM A615, Gr. 40
. ... ASTM A615, Gr. 60
......... 3,000 psi@ 28 days
.. Assumed, Class 4 soil (SW, SP, SM,
SC, GM, GC) per CBC Table 1806.2
Note: Container and all items within or attached to the container are designed and detailed by others.
LANE ENGINEERS, INC.
979 N. Blackstone Street • Tulare, California 93274
www.laneengineers.com
(559) 688-5263
_______ 2_o·_c_o_NT_A_1N_E_R _______ SHEET 2 OF 6 PROJECT
CLIENT
BY
_______ T_u_RP_IN_&_RA_TT_AN _______ JOBNO. ____ 1_80_61 ___ _
JA CHKD BY ------DATE
1. 20' Container i'~ u''
11' >f
WoL = 4,585 lbs -t
W1,L = 125 psf (20')(8 ') = 20,000 lbs I i
I 1
I
i
I I , I i
2. I,oading
Wind ->
F = q,GCrAr [ASCE 7-10, EQ. 29.5-1]
q,= 0.00256(0.85)(1.0)(0.85)(110)2 = 22.4 psf
T = 0.02(8.5)°-75 = 0.1 sec -> f = 1 /0.1 = 10 Hz -> G = 0.85
B/s = 20/8.5 =}
s/h = 85/8.5 =
8.5'
2.35 -> Cr= 1.4 (Cases A&B)
1
11.5'
1.o•
( 1.57-0.75)(0.8) = 0.66
(2.37-0.75)(0.8) = 1.30
} Cf for Case C
Case A: F = 22.4(0.85)(1.4) = 26.7 psf [At Center]
Case B: F = 26.7 psf [At 0.2B = 0.2(20') = 4' from center]
Case C:
I LI
F, = 22.4(0.85)(1.3) = 24.8 psf
c' Fi= 22.4(0.85)(0.66) = 12.6 psf
·I
LANE ENGINEERS, INC.
979 N. Blackstone Street • Tulare, California 93274
www.laneenglneers.com
(559) 688-5263
_______ 2_o·_c_oN_T_AI_N_E_R _______ SHEET 3 OF 6 PROJECT
CLIENT
BY
_______ T_U_RP_IN_&_RA_TT_AN _______ JOBNO. ____ 18_0_61 ___ ~
JA CHKDBY DATE ------
Case A:
VwA = 26.7 psf(20')(8.5') = 4,539 lbs
Mor= 4539[8.5/2 + 0.05(8.5)] = 21,220 lb-ft
21,220 lb-ft
TFTG = ±1,326 lbs 8 1(2 ftgs)
4,539 lb
VFTG= 1,135 lbs (4 ftgs)
Case B:
Vw0 = 4,539 lbs
MoT = 21,220 lb-ft
TFTo = ±1,326 lbs
I
4,5391b(*7)
VFTo = ( f ) = 1,589 lbs 2 tgs
Case C:
Vwc = 22.8 psf(8.5 ')(8.5 ') + 12.6 psf(8.5')( 11.5 ') = 1,647 + 1,232 = 2,879 lbs
Mor= 2879[8.5/2 + 0.05(8.5)] = 13,459 lb-ft
13,459 lb-ft
TFTo = '( ) +841 lbs 8 2 ftgs -
(
15 75') 5 75' VFTo = 1,647 -· ,-+ 1,232(-· -, ) = 1,135 !bs 20 20
::i Case B Governs
LANE ENGINEERS, INC.
979 N. Blackstone Street • Tulare, California 93274
www.laneenglneers.com
(559) 688-5263
_______ 2o_·_c_oN_T_A_IN_E_R _______ SHEET 4 OF 6 PROJECT
CLIENT
BY
_______ T_U_RP_IN_&_RA_TT_AN _______ JOBNO. ____ 18_0_61 ___ ~
JA CHKD BY ------DATE
Earthquake -+
Risk Category II, Site Class D
Ss = 1.70 -+ Sos= 1.13
S1 = 0.75 -+ S01 = 0.75
C = Sosle = 1.13(1.0) = O. l? 4 s R 6.5 (ASCE Eq. 12.8-2)
V = 0.174[4,585 + 0.25(20,000)] = 1,668 lbs ('Strength')
MOT= 1,668(8.5' /2) = 7,088 lb-ft
7,088 lb-ft
TFTG = '( f ) = ±443 lbs 8 2 tgs
1,668 lb
( = 417 lbs VFTG 4 ftgs)
Snow -+
Pr= 0.7C,Ctlspg [ASCE 7-10, eq. 7.3-1]
pg= 5 psf
Cc= I.I
C, = 1.0
I,= 1.0
Pr= 0.7(1.1)(1.0)(l.0)(5 psf) = 4 psf
Pr, m;n = 1.(20) = 20 psf
Wsnow = 20 psf(8')(20') = 3,200 lbs
LANE ENGINEERS, INC.
979 N. Blackstone Street • Tulare, California 93274
www.laneengineers.com
(559) 688-5263
________ 20_· _co_N_T_AI_N_E_R _______ SHEET 5 OF 6 PROJECT
CLIENT
BY
_______ TU_R_P_IN_&_RA_TT_AN _______ JOB NO. ____ 1_a_os_1 ___ ~
JA CHKDBY ------DATE
3. Footing Design
PoL = 4,585/4 ftgs = 1, 146 lbs
PRL = 20psf (8')(20')/4 = 800 lbs
PLL = 20,000 lbs/4 = 5,000 lbs
PsL = 3,200 lbs/4 = 800 lbs
PwL = ± 1,326 lbs
PEL= ±443 lbs
--> See Enercalc analysis
VwL = 1,589 lbs
VEL = 417 lbs
Option 1: Square Footing, with and without slab
3 '-6" sq. x 1 '-0" thick footing w/ 3-#5 each way at top and bottom
Option 2A: Pole-type footing, no slab
2' -0" diameter x 4' -0" thick footing w/ 6-#5 vertical equally spaced and
#3 ties at 12"o.c.
Option 2B: Pole-type footing, with slab
2 '-0" diameter x 1 '-6" thick footing w/ 6-#5 vertical qually spaced and #3
ties at 12" o.c.
4. Anchorage
Option I: 12" square plate w/ N.S.A.
Vertical {
Horizontal {
0.9D + I.OW= 0.9(4585/4) -1,135 = -103 lbs
0.90 + 1.0E = 0.9(4585/4)-443 = 588 lbs--> No uplift
0.90 +I.OW= 0.9(0)-1,589 = -1589 lbs
0.9D +I.OE= 0.9(0)-417 = -417 lbs
For square footings --> See Profis calculations in appendix
Nu= 103 lbs
Vu= 1,589 lbs
LANE ENGINEERS, INC.
979 N. Blackstone Street Tulare, California 93274
www.laneenglneers.com
(559) 688-5263
20' CONTAINER SHEET 6
TURPIN & RATTAN JOB NO.
OF
18061
6 PROJECT
CLIENT
BY
--------~ JA CHKD BY DATE ------
For pole-type footings, see Profis calculations in appendix and below
F bd2 36,000(0.5)2 Mn= Mp = FyZ = ~Y'---= ---~--'-= 2,250 lb-in/in 4 4
q>Mn = 0. 9(2,250) = 2,025 lb-in/in I
Pup(4.S") Mc=-~-~
12" wide
·~ Pup
4 5" I .
I
12" (2,025 lb-in/in)
Pup= 4_5,, = 5,400 lbs -> Minimum ductile yielding of plate
<pNn = 18,032 lbs
5,400 lbs< 18,032 lbs
Connection ->
-> Concrete breakout per Profis anchor program
-> Attachment will undergo ductile yielding prior to
concrete edge failure!
12" SQUARE PLATE X Yi'' THICK
WITH 4 -5/8" DIA. N.S.A.
Rw,14 = 1.39(4) = 5.56 k/in
Try 5" long for 2-sides (IO" total)
R101al = 5.56(1 O") = 55.6 kips .,/ o.k.
\4'' FILLET WELD, 2-SIDES OF
CORNER FITTING, TYP. EACH
CORNER
APPENDIX
Computer Calculations
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
Description : 20' Container Footing (Square, No Slab)
Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Material Properties
re : Concrete 28 day strength
fy : Rebar Yield
Ee : Concrete Elastic Modulus
Concrete Density
<p Values Flexure
Shear
Analysis Settings
Min Steel % Bending Reinf.
Min Allow % Temp Reinf.
= = = =
=
=
2.50 ksi
60.0 ksi
2,850.0 ksi
145.0 pcf
0.90
0.850
= =
=
0.00180
1.0 : 1
Project Title: A-1 of 12
Engineer: Project ID:
Project Descr:
~nn:ed 28 FEB 2018 11 18"M
File= J:\lobs\2018118051\Project Documents\CalaJ!ations\18051 calcs.ec6
ENERCALC, INC. 1983-2017, Bulld:10.17.12.10, Ver.10.17.12.10
Soil Design Values
Allowable Soil Bearing
Increase Bearing By Footing Weight
Soil Passive Resistance (for Sliding)
Soil/Concrete Friction Coeff.
Increases based on footing Depth
Footing base depth below soil surface
Allow press. increase per foot of depth
when footing base is below
=
=
=
=
=
=
=
2.0 ksf
No
300.0 pcf
0.250
1.750ft
ksf
ft Min. Overturning Safety Factor
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Fig Wt for Soil Pressure
Use ftg wt for stability, moments & shears
Add Pedestal Wt for Soil Pressure
Use Pedestal wt for stability, mom & shear
Dimensions
Width parallel to X-X Axis
Length parallel to Z-Z Axis
Footing Thickness
= =
=
3.50 ft
3.50 ft
12.0 in
Yes Allowable pressure increase per foot of depth
Yes
No
No
when max. length or width is greater than =
=
ksf
ft
~
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
Description : 20' Container Footing (Square, No Slab)
DESIGN SUMMARY
Min. Ratio Item
PASS 0.3234 Soil Bearing
PASS n/a Overturning -X-X
PASS 1.308 Overturning -Z-Z
PASS 1.628 Sliding -X-X
PASS n/a Sliding -Z-Z
PASS 2.204 Uplift
PASS 0.1176 Z Flexure (+X)
PASS 0.1176 Z Flexure (-X)
PASS 0.1176 X Flexure (+Z)
PASS 0.1176 X Flexure (·Z)
PASS 0.08823 1-way Shear (+X)
PASS 0.08823 1-way Shear (-X)
PASS 0.08823 1-way Shear (+Z)
PASS 0.08823 1-way Shear (-Z)
PASS 0.1689 2-way Punching
Project Title:
Engineer:
Project Descr:
A-2 of 12
Project ID:
Pnn:ea 28 FEB 20'8 11 '8AM
File= J:\Jobs\2018118051\Project Documenls\Calrulations\18051 calcs.ec6
ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
-----------------~-·@:1i•ieH1--
Applied
0.6467 ksf
0.0 k-ft
2.346 k-ft
0.9534 k
0.0 k
-0.7956 k
1.222 k-ft/ft
1.222 k-ft/ft
1.222 k-ft/ft
1.222 k-ft/ft
7.499 psi
7.499 psi
7.499 psi
7.499 psi
28.710 psi
Capacity
2.0 ksf
0.0 k-ft
3.068 k-ft
1.552 k
0.0 k
1.753 k
10.388 k-ft/ft
10.388 k-ft/ft
10.388 k-ft/ft
10.388 k-ft/ft
85.0 psi
85.0 psi
85.0 psi
85.0 psi
170.0 psi
Goveming Load Combination
+D+L about Z-Z axis
No Overturning
+0.60D+0.60W
+0.60D+0.60W
No Sliding
+0.60D+0.60W
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1.20D+0.50Lr+1.60L
+1 .20D+0.50Lr+1.60L
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
Description: 20' Container Footing (Square, w/ Slab)
Code References ---
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used: ASCE 7-10
General Information
Material Properties
fc : Concrete 28 day strength
fy : Rebar Yield
Ee : Concrete Elastic Modulus
Concrete Density
q, Values Flexure
Shear
Analysis Settings
Min Steel % Bending Reinf.
Min Allow % Temp Reinf.
=
= = =
=
=
2.50 ksi
60.0 ksi
2,850.0 ksi
145.0 pcf
0.90
0.850
= =
=
0.00180
1.0 : 1
Project Title:
Engineer:
Project Descr:
A-3 of 12
Project ID:
Pnnted 28 FEB 2018 1118AM
File= J:\Jobs\2018118051\Project Documents\Calculations\18051 calcs.ec6
ENERCALC, INC.1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Soil Design Values
Allowable Soil Bearing
Increase Bearing By Footing Weight
Soil Passive Resistance (for Sliding)
Soil/Concrete Friction Coeff.
Increases based on footing Depth
Footing base depth below soil surface
Allow press. increase per foot of depth
when footing base is below
= = = =
= = =
2.0 ksf
No
300.0 pcf
0.250
1.750ft
ksf
ft
Min. Overturning Safety Factor
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Fig Wt for Soil Pressure
Use ftg wt for stability, moments & shears
Add Pedestal Wt for Soil Pressure
Use Pedestal wt for stability, mom & shear
Dimensions
Width parallel to X-X Axis
Length parallel to Z-Z Axis
Footing Thickness
Pedestal dimensions ...
px : parallel to X-X Axis
pz: parallel to Z-2 Axis
Height
=
=
=
= = =
Rebar Centerline to Edge of Concrete ...
at Bottom of footing =
Reinforcin
Bars parallel to X-X Axis
Number of Bars
Reinforcing Bar Size
Bars parallel to Z-Z Axis
Number of Bars
Reinforcing Bar Size
=
= =
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
# Bars required within zone
# Bars required on each side of zone
Ap lied Loads
D
#
#
3.50 ft
3.50 ft
12.0 in
in
in
in
3.0 in
3.0
5
3.0
5
n/a
n/a
n/a
Lr
Yes Allowable pressure increase per foot of depth
Yes
No
No
when max. length or width is greater than
z 3·~·
L S W E
=
=
H
ksf
ft
------------------------------------P : Column Load = 1.146
OB : Overburden =
M-xx =
M-zz =
V-x =
V-z =
0.80 5.0 0.80 -1.135 -0.4430
1.589 0.4170
k
ksf
k-ft
k-ft
k
k
~
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
Description : 20' Container Footing (Square, w/ Slab)
DESIGN SUMMARY
Min. Ratio Item
PASS 0.3255 Soil Bearing
PASS n/a Overturning -X-X
PASS 1.430 Overturning -2-2
PASS 2.575 Uplift
PASS 0.1176 2 Flexure (+X)
PASS 0.1176 2 Flexure (-X)
PASS 0.1176 X Flexure (+2)
PASS 0.1176 X Flexure (-2)
PASS 0.08823 1-way Shear (+X)
PASS 0.08823 1-way Shear (-X)
PASS 0.08823 1-way Shear (+2)
PASS 0.08823 1-way Shear (-2)
PASS 0.1689 2-way Punching
Project Title: A-4 of 12
Engineer: Project ID:
Project Descr:
PMted· 28 FEB 2018 11 '8AM
File= J:\Jobs\2018118051\Project Oocuments\CalaJfalions\18051 calcs.ec6
ENERCAlC, INC. 1983-2017, Build:10.17.12.10, Ver.10.17.12.10
___________________ •IMH,C-1 __
Applied
0.6510 ksf
0.0 k-ft
2.145 k-ft
-0.6810 k
1.222 k-ft/ft
1.222 k-ft/ft
1.222 k-ft/ft
1.222 k-ftfft
7.499 psi
7.499 psi
7.499 psi
7.499 psi
28.710 psi
Capacity
2.0 ksf
0.0 k-ft
3.068 k-ft
1.753 k
10.388 k-ft/ft
10.388 k-ft/ft
10.388 k-ft/ft
10.388 k-ft/ft
85.0 psi
85.0 psi
85.0 psi
85.0 psi
170.0 psi
Governing Load Combination
+D+0.750L +0.750S+0.450W about 2-2 al
No Overturning
+0.60D+0.60W
+0.60D+0.60W
+1.20D+0.50Lr+ 1.60L
+1 .20D+0.50Lr+1 .60L
+1 .20D+0.50Lr+1 .60L
+1.20D+0.50Lr+1 .60L
+1 .20D+0.50Lr+1 .60L
+1 .20D+0.50Lr+1 .60L
+1.20D+0.50Lr+1 .60L
+1.20D+0.50Lr+1.60L
+1 .20D+0.50Lr+1.60L
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
dded in Soil
Description : 20' Container Footing (Pole, No Slab)
Code References
Calculations per IBC 2015 1807.3, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Pole Footing Shape
Pole Footing Diameter .......... .
Calculate Min. Depth for Allowable Pressures
No Lateral Restraint at Ground Surface
Allow Passive ................. .
Max Passive ..............•....
Controlling Values
Governing Load Combination : +D+0.60W+H
Lateral Load
Moment
NO Ground Surface Restraint
Pressures at 1/3 Depth
Actual
Allowable
Minimum Rlqulnd Depth
Footing Base Area
Maximum Soil Pressure
Applied Loads
Circular
24.0 in
300.0 pcf
1,500.0 psi
0.9534 k
0.2384 k•ft
346.753 psi
346.958 psi
3.50 ft
3.14211•2
1.956 ksf
Project Title: A-5 of 12
Engineer: Project ID:
Project Descr:
Pnn:ed 28 FEB 2018. 11 18AM
File= J:Uobs\2018118051\Project Documents\Calculations\18051 calcs.ec6
ENERCALC, INC. 1983-2017, Bu~d:10.17.12.10, Ver:10.17.12.10
Soil Surface No lateral restraint M
Lateral Concentrated Load (k) Lateral Distributed Loads (kif) Vertical Load (k)
D: Dead Load
Lr : Roof Live
L: Live
S: Snow
W:Wind
E : Earthquake
H : Lateral Earth
Load distance above
ground surface
k
k
k
k
1.589 k
0.4170 k
k
0.250 ft
Load Combination Results
Load Combination
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0.750Lr+0.750L +H
+D+0.750L +0.750S+H
+D+0.60W+H
+D+0.70E+H
+D+O. 750Lr+O. 750L +0.450W+H
TOP of Load above ground surface
BOTIOM of Load above ground surface
Forces @ Ground Surfaoe
Loads· (k) Moments • (ft-k)
0.000 0.000
0.000 0.000
0.000 0.000
0.000 0.000
0.000 0.000
0.000 0.000
0.953 0.238
0.292 0.073
0.715 0.179
k/ft
k/ft
k/ft
k/ft
k/ft
k/11
kilt
ft
ft
Required
Depth. (ft)
0.13
0.13
0.13
0.13
0.13
0.13
3.50
2.00
3.13
Pressure at 1 /3 Depth
1.1 46 k
0.80 k
5.0 k
0.80 k
-1.135 k
·0.4430 k
k
Soil Increase
Actual • (psf) Allow • (psf) Factor
0.0 0.0 1.000
0.0 0.0 1.000
0.0 0.0 1.000
0.0 0.0 1.000
0.0 0.0 1.000
0.0 0.0 1.000
346.8 347.0 1.000
196.6 197.7 1.000
301.7 302.3 1.000
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
dded in Soil
Description : 20' Container Footing (Pole, No Slab)
+D+O. 750L +O. 750S+0.450W+H
+D+O. 750L +O. 750S+0.5250E+H
+0.60D+0.60W+0.60H
+0.60D+O. 70E+0.60H
0.715 0.179
0.219 0.055
0.953 0.238
0.292 0.073
Project Title: A-6 of 12
Engineer: Project ID:
Project Descr:
Pno:ed. 28 FEB 2018 11 18A\.I
File= J:\Jobs\2018118051\J>rojed Documenls\Calculations\18051 calcs.ec6
ENERCALC, INC. 1983-2017, Bu~d:10.17.12.10, Ver:10.17.12.10
3.13 301.7 302.3 1.000
1.75 171.6 172.8 1.000
3.50 346.8 347.0 1.000
2.00 196.6 197.7 1.000
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
dded in Soil
Description : 20' Container Footing (Pole, w/ Slab)
Code References
Calculations per IBC 20 151807.3, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Pole Footing Shape
Pole Footing Diameter .......... .
Calculate Min. Depth for Allowable Pressures
Lateral Restraint at Ground Surface
Allow Passive ................. .
Max Passive ............•......
Controlling Values
Governing Load Combination : +D+0.60W+H
Lateral Load
Moment
Restraint @ Ground Surface
Pressure at Depth
Actual
Allowable
Surface Retrain! Force
lltnnum Required Depth
Footing Base Area
Maximum Soil Pressure
Circular
24.0 in
300.0 pcf
1,500.0 psi
0.9534 k
0.2384 k-ft
324.156 psi
375.0 psi
1,358.60 lbs
3.142 ft'2
1.956 ksf
Project Title: A-7 of 12
Engineer: Project ID:
Project Descr:
Pnnted 28 FEB 2018 11 18AM
File= J:\Jobs\2018\18051\Project Documents\Calculalions\18051 calcs.ec6
ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver:10.17.12.10
Soil Surface Surface Lateral R~traint
L___j ~.-
Applied L.E_a~s __
Lateral Concentrated Load (k) Lateral Distributed Loads (kif) Applied Moment (kft)
k-ft
Vertical Load (k)
D: Dead Load
Lr : Roof Live
L : Live
S: Snow
W:Wind
E : Earthquake
H : Lateral Earth
Load distance above
ground surface
k
k
k
k
1.589 k
0.4170 k
k
0.250 ft
Load Combination Results
Load Combination
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0.750Lr+0.750L +H
+D+0.750L +0.750S+H
+D+0.60W+H
+D+0.70E+H
+D+0.750Lr+0.750L +0.450W+H
TOP of Load above ground surface
BOTIOM of load above ground surface
Forces @ Ground Surface
Loads • (k) Moments • (ft.k)
0.000 0.000
0.000 0.000
0.000 0.000
0.000 0.000
0.000 0.000
0.000 0.000
0.953 0.238
0.292 0.073
0.715 0.179
k/ft
k/ft
k/ft
k/ft
k/ft
k/ft
k/ft
ft
ft
Required
Depth. (ft)
0.13
0.13
0.13
0.13
0.13
0.13
1.25
0.88
1.13
k-ft
k-ft
k-ft
k-ft
k-ft
k-ft
Pressure at Depth
1.146 k
0.80 k
5.0 k
0.80 k
-1.135 k
-0.4430 k
k
Soil lnaease
Actual • (psi) Allow • (psi) Factor
0.0 37.5 1.000
0.0 37.5 1.000
0.0 37.5 1.000
0.0 37.5 1.000
0.0 37.5 1.000
0.0 37.5 1.000
324.2 375.0 1.000
202.5 262.5 1.000
300.1 337.5 1.000
Lane Engineers, Inc.
979 N. Blackstone St.
Tulare, CA 93274
559.688.5263
www.laneengineers.com
dded in Soil
Description : 20' Container Footing (Pole, w/ Slab)
+D+O. 750L +O. 750S+0.450W+H
+D+O. 750L +O. 750S+0.5250E+H
+0.60D+0.60W+0.60H
+0.60D+0.70E+0.60H
0.715 0.179
0.219 0.055
0.953 0.238
0.292 0.073
Project Title: A-8 of 1 2
Engineer: Project ID:
Project Descr:
Pnnted 2B FEB 2018 11 18AM
File= J:\Jobs\2018118051\S'roject Documents\Calculations\18051 calcs.ec6
ENERCALC, INC. 1983-2017, Build:10.17.12.10, Ver.10.17.12.10
1.13 300.1 337.5 1.000
0.75 206.8 225.0 1.000
1.25 324.2 375.0 1.000
0.88 202.5 262.5 1.000
www.hilti.us
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter:
Effective embedment depth:
Material:
Proof:
Stand-off installation:
Anchor plate:
Profile:
Base material:
Reinforcement:
Geometry [in.] & Loading [lb, in.lb]
.. ,,--. •. Profis Anchor 2.7.5
Page:
Project:
Sub-Project I Pos. No.:
Date: 2/28/2018
1 \ AWS D1 .1 GR. B 5/8
h01 = 6.000 in.
Design method ACI 318-14 / CIP
eb = 0.000 in. (no stand-off); t = 0.500 in.
I, x ly x t = 12.000 in. x 12.000 in. x 0.500 in.; (Recommended plate thickness: not calculated
no profile
cracked concrete, 2500, fc' = 2500 psi; h = 12.000 in.
tension: condition B, shear: condition B;
edge reinforcement: none or < No. 4 bar
z :
I
',,
', I "',• ,.., .... ,
I ', J _. .. : .
I ..... ··
' '
' '
.. ,,, •. Profis Anchor 2. 7 .5 www.hilti.us
Company: ----~--~~-----~-----------Page:
Specifier: Project
Address: Sub-Project l Pos. No.:
Phone I Fax: Date:
E-Mail:
2 Proof I Utilization (Governing Cases)
Design values [lb] Utilization
Loading
Tension
Shear
Proof
Steel Strength
Load ----26-
Concrete edge failure in direction y+ 1589
Capacity
14966
12473
~" /~v [%]
1 / -
-/ 13
2
2/28/2018
Status oi<~--
OK
Loading PN Pv t; Utilization PN,v [0/o] Status
Corribined tension and shear loads · 0.004 --0.127 5/3 4 OK
3 Warnings
Please consider an details and hints/warnings given in the detailed report!
Fastening meets the design criteria!
4 Remarks; Your Cooperation Duties
• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.
www.hilti.us
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter:
Effective embedment depth:
Material:
Proof:
Stand-off installation:
Anchor plate:
Profile:
Base material:
Reinforcement:
Geometry [in.] & Loading [lb, in.lb]
AWS 01.1 GR. B 5/8
h01 = 6.000 in.
Design method ACI 318-14 / CIP
eb = 0.000 in. (no stand-off); t = 0.500 in.
Page:
Project:
Sub-Project I Pos. No.:
Date:
.. ,,---. •. Profis Anchor 2.7.5
2/28/2018
l l
Ix x ly x t = 12.000 in. x 12.000 in. x 0.500 in.; (Recommended plate thickness: not calculated
no profile
cracked concrete, 2500, fc' = 2500 psi; h = 18.000 in.
tension: condition B, shear: condition B;
edge reinforcement: none or < No. 4 bar
' z : I
I
I
I ~t
,, _ ..... ., ! ",, I ....
I •
't--
() ... ~-~------
-~------\,J
.... ,0.5
' ' ' ' ' , X
' '
.. ,,--. •. www.hilti.us __ _ ------------
Company: Page:
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone 1 Fax: Date:
E-Mail:
---------------------------
2 Proof I Utilization (Governing Cases)
Design values [lb] Utilization
Loading
Tension
Shear
Proof Load
Steel Strength
_____ 26 __ _
Concrete edge failure in direction y+ 1589
Capacity
14966
5789
P• I Pv [%]
1 / -
- I 28
Profis Anchor 2.7.5
2
2/2812018
Status ---OK
OK
Loading p.
0.004
~ Utilization PN.v [o/o] Status
OK Combined tension and shear loads 5/3~---12
3 Warnings
Please consider all details and hints/warnings given in the detailed report!
Fastening meets the design criteria!
4 Remarks; Your Cooperation Duties
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilt\ will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.
---------------------------------------------------
OFFICE USE ONLY SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
RECORDID#------------------1 PLAN CHECK# ___________________
1
BP DATE
-55"'1 -
State APN#
A L\ '5 -OSO-Z..-1-OC)
\\
Project Contact
I l ,,
Applicant E·mail
M\c,..
t, State Plan File#
Telephone#
The follow g questions represent the facil" s activities, NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San
Diego}: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled,
applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: \:) Facility's Square Footage (including proposed project):
1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives
2. Compressed Gases 6. Oxidizers 10. Cryogenics
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
13.
14.
15.
Corrosives
Other Health Hazards
None of These.
PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION CHMD): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123.
FEES ARE REQUIRED Project Completion Date: { I '6 Expected Dale of Occupancy: I" c~ D CalARP Exempt
Call (858) 505-6700 prior to the issuance of a building permit. (i t /
YES NO (for new construction or remodelin projects) =------'-' =-~--
1. D .fl ls your business listed on the reverse side of this form? (check all that apply). Date Initials
2. 0 fl Will your business dispose of Hazardous Substances or Medical Waste in any amount?
3. D Ja" Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 D CalARP Required
pounds and/or 200 cubic feet?
4. D ,e:( Will your business store or handle carcinogens/reproductive toxins in any quantity? Date Initials
5. D ~ Will your business use an existing or install an underground storage tank?
6. D :g Will your business store or handle Regulated Substances (CalARP)? D CalARP Complete
7. D ~ Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
8. D -I/ Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to Date Initials
or reater than 1,320 allons? California's Above round Petroleum Stora e Act .
PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT CAPCDl: Any YES' answer requires a stamp from APCD 10124 Old Grove Road, San
Diego, CA 92131 apcgcomp@sdcounty.ca.gqv (858) 586-2650). [*No stamp required if 01 Yes aJJg, 03 Yes aJJg, 04-06 No]. The following questions are intended
to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive
requirements contact APCD. Residences are typically exempt, except -those with more than one building+ on the property; single buildings with more than four
dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [ .. Excludes garages & small outbuildings.]
YES NO
1. D E:1' Will the project disturb 160 square feet or more of existing building materials?
2. D H Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition.
3. D D (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance
Technician?
4. D D (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 1 O working days prior to commencing asbestos removal.
5. D ,,E( Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet
(www.sdapcd.org/info/facts/permits.pdf) for typical equipment requiring an APCD permit.
6. D D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda
Briefly describe proposed project:
c ,rvy I< A.l_ n:.c.
I declare under penalty of pet;ju_ry that to the best of my knowledge and belief tlie esponses made herein are true and f\c,r,-L, tp.K<',Jf
Date
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION·
BY: DATE: I I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO* APCD COUNTY-HMO APCD COUNTY-HMO APCD
"A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other perm1tt1ng requirements may still apply.
HM-9171 (08/15) Countv of San Dieqo -DEH -Hazardous Materials Division