HomeMy WebLinkAbout2177 SALK AVE; 100 | 200; PC140006; Permit07-11-2014 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No: PC140006 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: VALENTE KIM 2177 SALKAV CBAD PLANCK 2120210300 Lot#: $0.00 Construction Type: CALAMP Tl - 22,501 SF TOTAL // 11,428SF SHELL TO OFF 1ST FL STE 100 7/11,073 SF Status: ISSUED Applied: 03/06/2014 Entered By: SKS Plan Approved: 04/15/2014 Issued: 04/15/2014 Inspect Area: Owner: VENTANA REAL LLC 4944 COLLINGWOOD DR SAN DIEGO CA 92109-2243 858-794-3222 1525 FARADAY AVE #100 CARLSBAD CA 92008 Plan Check Fee $2,480.40 Additional Fees $0.00 Total Fees: $2,480.40 Total Payments To Date: $2,480.40 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project Includes the "imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions, If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carisbad iVIunicipai Code Section 3.32.030. Failure to timely foiiow that procedure will bar any subsequent legal action to attacl<, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other simiiar appiication processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previouslv been given a NOTICE simiiar to this, or as to which the statute of limitations has oreviouslv othenvise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMrr ISSUANCE: CITY Of CARLSBAD |t^|^NNING I^IISGINEERING [^BUI|!DING • HEALTH • HAZMAT/APCD Building Pennit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax:760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov 9^ Plan Check No. Est.Value 'ZZA Plan Ck. Deposit Z(^^ MO Date ;k. P^i 2i SWPPP JOB ADDRESS Z\-r\ SaiKAve SUITE*/SMCE«/UNIT* CT/PROJECT # # BATHROOMS TENANT BUSINESS NAME Cal Amp CONSTR. TYPE DESCRIPTION OF WORK: /nc/ud* Squara FMt of Affected ATM^*; Tl in cxis-h'njy offee buildmc- Hcix^ ujo.\Vs, cioons, S(cLGlC5kts, ce\\inoj, ^tf>uocr/sV<;V\aJi ccnd iJ^mis,V\^S. NoV'^CO-f' rvuson-t-CcJ BVAO L^ni-^^ • WliVciXjfefvMOTd:^. EXBTING USE 5H€U_- (CO PROPOSED USE 7 ^fiAl ARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES|~k No(?n AIR CONDITIONING YES I FIRE SPRINKLERS YES^NOQ APPUCANTNAME Primanf Contact Kim Va.len'f< PROPERTY OWNER NAME ADDRESS H^q-H CollinqoXDci Dr. STATE ADDRESS i 1 STATE TI ZIP xrr _ CITY PHONE San t>t'€g\o ZIP CITY Cos febcxd FAX PHONE EMAIL EMAIL A^OR DESNN PROFESSIONAL ADDRESS ^ STATE Dr: ^iW~ ^ ; . *rATE ZIP., cmr \ s-> CA ZIP ZIP. I TO) I PHONE FAX EMAIL 1 ISTATELIC.# EMAIL CLASS OTY (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commendirig with Section TOOOof Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis fbr the alleged exemption. Any violation of Section 7031.5 by any applicantfor a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Woriiifs'Coinpensation Decliralloii: / (lersty affl^ under penally of pei^ 111 have and wM maintain a ctrHfieal* of coment to selHnsur* for woricers' compensation as provided by Section 3700 of the Labor Code, for the performance of the worii for which this pemiit is issued. Jiy I have and wM maintain vrorjm'compensation, as required by^^^ number are: Insurance Co.tT? 10vVK> _ Policy No. I Expiration Date Thjsssction need not be completed if the pennit is for one hundred dolbra ($100) or less. [M^itMcala of Exemption: I certify that in the perfonnance of the work for which this pem»t is issued, I cSlhmia. WARNING: Faiura to secure woikars' compensation coverage b unlawful, and shal suhiict an employer to criminal penalties and civil fines up to one hundred thousand dolais (t1W,000), in adtNUon to tha cost of compensatian, damages as provided for In Section 3706 of the LJIMW code, InlMest and attorney's Im CONTRACTOR SIGNATURE ^^^^(Z0^k^ ^AGENT DATE O IV N E R - B U I L D E R DECLARATION / Aen9(>y affimi tfiaf / «n exsflV)! I^om Contrsctor's UiwnM I I I, as oimm of the ptoperty or my employees with wages as M sole convensatioii, will ^ License Law does not apply to an owner of property who builds or improves thereon, and who does iuch worit himtelf ^ sale. If, however, the building or improvement is sold within one year of conipletlon, the owner-builder 1^ I I I, as owner of the property, am exdusively contracting with icensed oontractcrs ID constnict Ihe project (Sec. 7044, Business and Prolessions Code: The Contractor's License Law does not apply to an owner of property who buMs or improves thereon, and contracts fur such projects with contractorts) licensed puisuant to the Contractor's License Law). {~| I am exempt under Section Business and Professions Code fbr this reason: 1.1 personaly plan to provide the major labor and materials for constnKtion of the proposed property ImproveinenL I IVes I tto 2.1 (have / have not) signed an applicatian fbr a buiding permit for the proposed worit. 3.1 have contracted with the following person (firni) to provide the proposed constnKtion (include name address / phone / contractors' license number): 4.1 plan fo provide portions of the worit, but I have hired the following person to cooniinate, supenrise and provide the major worit (include name / address / phone / contractors' license number): 5.1 wi provide some of the worit, but I have contracted (hired) the folowing persons to provide the worit indicated (include name / address / phone / type of worit): ^PROPERTY OWNER SiGNATURE •AGENT DATE COMPLETE THIS SECTION FOR NON-RESIOENTIAL BUILDING PERMITS ONLY Yes A No Is Ihe applicant or future building occupant required to submit a business t>lan, acutely hazanlous materials registration form or risIt management and prevention program under Sections 2S50S, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes X No Is Ihe applicant or future building occupant required to obtain a pennit Mm me air pollution control disbict or alMUality management district? Is Ihe ladlity to be constnicted within 1,000 feet of the outar boundary of a school site? Yes /\No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED IMLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affinn that there is a construction lending agency for the perfonnance of the work this pennit Is issued (Sec. 3097 (i) Civii Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I ceri% that I hwe read the application and state that the above infomiation Is conect and that the inforrnatlan on the plans Is acra I heieby authoiiffi representative of the City of Cailsbad to enter upon the above iiient^ AGAINST Aa UABLUES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRAMTWG OF THIS PERMfT. OSHA'An OSHA pennit is required for excavations over St)'deep and demoHion w constaiction of studio EXPffMTION: Eveiy pennit issued by Ihe Buiding Ofliciai under Ihe pravisians of Ihis Code shal exp^ 180 days film Ihe date of such pennit or if V« buiding or worit authorized by such pemil is suspended ^ APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BMILDING PERMIT ISSUANCE. Complete the following ONLY If a Certificate of Occupancy will be requested at final Inspection. Fax (760) 602-8560, EmaH buildina(3>carlsbadca.Q0V or MaH the completed fonn to City of Cailst>ad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008. C0#: (OfdcoUeaOnly) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANTS BUS. LK. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Usted above) CONTRACTOR (On P(. 1) MAILTO: CONTACT (Usted above) OCCUPANT (Usted above) CONTRACTOR (On Pg. 1) MAIL/FAX TO OTHER: ASSOCUTEDCBf NO CHANOE IN USE / NO CONSTRUCTION CHANOE OF USE / NO CONSTRUCTION ASSOCUTEDCBf NO CHANOE IN USE / NO CONSTRUCTION CHANOE OF USE / NO CONSTRUCTION ^CTAPPUCANTS SIGNATURE MTE EsGil Corporation In PartnersAip witA government for (BuiCding Safety DATE: 4/4/14 • APPLICANT • JURIS. JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: PC14-0006 SET: II PROJECT ADDRESS: 2177 Salk Ave Suite 100 & 200 PROJECT NAME: Calamp - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mall Telephone Fax In Person XI REMARKS: Applicant to include the red inked note on sheet T.1 ofthe attached perforated plans, on the City plans. By: Doug Moody (SA) Enclosures: EsGil Corporation • GA • EJ • MB • PC 3/28/14 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In PartnersAip witA government for (BuiCding Safety DATE: 3/20/14 • APPLICANT • JURIS. JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: PC14-0006 SET: I PROJECT ADDRESS: 2177 Salk Ave Suite 100 & 200 PROJECT NAME: Calamp - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonA/ard to the applicant contact person. I I The applicant's copy of the check list has been sent to: I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kim Valente Telephone #: 858-794-3222 Date contacted: (by: V^) Email: kratte@designcorpsd.com Fax #: ^ Mail /Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • MB • PC 3/10/14 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad PC14-0006 3/20/14 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PC14-0006 JURISDICTION: City of Carlsbad OCCUPANCY: B USE: Office TYPE OF CONSTRUCTION: VB ACTUAL AREA: 2250 Isf ALLOWABLE FLOOR AREA: STORIES: 2 HEIGHT: SPRINKLERS?: Yes OCCUPANT LOAD: 253 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 3/6/14 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/10/14 DATE INITIAL PLAN REVIEW COMPLETED: 3/20/14 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval ofthe plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. City of Carlsbad PC14-0006 3/20/14 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as follows: a) Ceiling areas over 2500 ft.^ must have seismic separation joints or full height partitions that break the ceiling into areas not exceeding 2500 ft.^. Please indicate the location of the joints and reference the correct details. 2. Please revise the plans to show the required emergency egress lighting per section 1006.3 ofthe CBC. The photometric analysis shows required exit aisles that appear not to be provided with the minimum 1 foot candle at the floor. 3. Please revise the single line diagram to show the grounding location of the new transformers to be per section 250-30 A (4) of the NEC. 4. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the new transformers. The detail provided shows the transformers to be supported by concrete walls yet the locations where the new transformers will be installed do not have concrete walls for support. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 5. Please have the document author and the principle designer of the LTG-1C form sign the imprinted document. 6. Please complete the LTG-1-C part 3 of 4 mandatory automatic controls portion of the LTG-1-C forms to show the new occupancy sensors. City of Carlsbad PC14-0006 3/20/14 7. Please have the principle designer complete the Statement of Compliance System Acceptance section of the LTG-1-C part 4 of 4 documents to show the new occupancy sensors. 8. Please have the document author and the principle designer of the MECH-1 C form sign the imprinted document. 9. Please provide the installation information for the heat chamber the name plate indicate ventilation must be provided. 10. Please revise the plumbing plans to show the required clean-outs per section 707 of the UPC at the new sink. Advisory Note : When alterations, structural repairs or additions are made to an existing building, that building, or portion ofthe building affected, is required to comply with all ofthe following requirements, per Section 11B-202.4: • The area of specific alteration, repair or addition must comply as "new" construction. • A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. • The path of travel shall include the existing parking. • Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. 11. It is appears from the plans the showers servicing the tenant improvement are not disabled accessible, please provide a dimensioned showers plans showing the showers to be accessible compliant To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad PC14-0006 3/20/14 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC14-0006 PREPARED BY: Doug Moody DATE: 3/20/14 BUILDING ADDRESS: 2177 Salk Ave Suite 100 & 200 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl 22501 37.12 835,237 Air Conditioning Fire Sprinklers TOTAL VALUE 835,237 Jurisdiction Code cb By Ordinance BIdg. Permt Fee by Ordinance ^ Plan Checl< Fee by Ordinance • Type of Review: 0 Complete Review QRepetitive Fee ^ Repeats • Other |—I Hourly EsGil Fee • Structural Only Hr. @ * $3,379.14 $2,196.44 $1,892.32 Comments: Sheet 1 of 1 macvalue.doc + PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE:03/25/14 PROJECT NAME: CALAMP PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2177 SALK #100 VALUATION: .$S3S^7^f^^ ^7 PROJECT ID: CB14-0541 APN: 212-021-03 / This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: KATHLEEN LAWRENCE 03/25/14 A Final Inspection by the Division is required Yes / No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: KRATTE@DESIGNCORPSD.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions. For questions or clarifications on thie attached checl<list please contact thie following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov / Kathleen Lawrence ^ 760-602-2741 Kathleen.Lawrence@carlsbadca.fiov Greg Ryan 760-602-4663 Grefiorv.Rvan@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.fiov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602-4662 Cvnthla.Wonfi@carlsbadca.fiov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.fiov Remarks: / f ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carisbadca.gov ENGINEERING Plan Check for CBI 4-0541 Date: 03/25/14 Project Address: 2177 SALK #100 Project Description: Tl SHELL TO OFFICE 11,428 SF APN: 212-021-03 Valuation: $835,237 ENGINEERING Contact: Kathleen Lawrenco Phone: 760-602-2741 Email: kathleen.lawrence@carlsbadca.gov Fax: 760-602-1052 RESIDENTIAL INTERIOR / TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$20,000.00) CARLSBAD PREMIER OUTLETS PLAZA CAMINO REAL COMPLETE OFFICE BUILDING OTHER: PCR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: KATHLEEN LAWRENCE REMARKS: DATE:03/25/14 Notification of Engineering APPROVAL has been sent to KRATTE@DESIGNC0RPSD.COM \ via EMAIL on 03/25/14 \ E-36 Page 1 of 1 REV 4/30/11 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: K LAWRENCE Date: 03/25/14 GEO DATA: LFMZ: / B&T: Address: 2177 SALK #100 BIdg. Permit #; CB14-0541 Fees Update by; KML Date; 03/25/14 Fees Update by; Date: 03/25/14 EDU CALCULATIONS: List types and square footages for all uses. Types of Use: OFFICE Sq.Ft./Units 11,428 SF EDU's 4.06 Types of Use: Sq.Ft/Units EDU's Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's ADT CALCULATIONS: List types and square footages for all uses. Types of Use: OFFICE Sq.Ft./Units 11,428 SF ADT's 171 Types of Use; Sq.Ft./Units ADT's Types of Use: Sq.Ft./Units ADT's Types of Use; Sq.Ft./Units ADT's FEES REQUIRED: Witliin CFD; YES (no bridge & thorougfifare fee in District #1, reduces Traffic Impact Fee) NO 1, PARK-IN-LIEU FEE: NW QUADRANT NE QUADRANT SE QUADARANT : ! SW QUADRANT ADT'S/UNITS; X FEE/ADT; =$ N/A • 2.TRAFFIC IMPACT FEE: ADT'S/UNITS; 171 X FEE/ADT; $97 =$ 16,587 3. BRIDGE & THOROUGHFARE FEE: / DIST#1 DIST.#2 : DIST.#3 ADT'S/UNITS; < FEE/ADT; =$ N/A • 4. FACILITIES MANAGEMENT FEE ZONE; • ADT'S/UNITS: X FEE/SQ.FT./UNIT: =$ N/A • 5. SEWER FEE EDU's 4.06 X FEE/EDU; 842 =$ 3418.52 BENEFIT AREA: F EDU's 4.06 X FEE/EDU; 3134 =$ 12724.04 0 6. DRAINAGE FEES: PLDA: HIGH MED UM :LOW ACRES; X FEE/AC; =$ N/A U 7. POTABLE WATER FEES; UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL .'.•If PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE:03/25/14 PROJECT NAME: CALAMP PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2177 SALK #200 VALUATION: $411,030 PROJECT ID: CB14 0542 APN: 212-021-03 / This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: KATHLEEN LAWRENCE 03/25/14 A Final Inspection by the Division is required Yes / No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: KRATTE@DESIGNCORPSD.OOM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.^ov / Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.fiov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for CB14-0542 Date; 03/25/14 Project Address: 2177 SALK #200 APN: 212-021-03 Project Description: Tl OFFICE TO OFFICE 11,073 SF Valuation: $411,030 ENGINEERING Contact: Kathleen Lawrenco Phone: 760-602-2741 Email: kathleen.lawrence@carlsbadca.gov Fax: 760-602-1052 RESIDENTIAL INTERIOR / TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$20,000.00) PLAZA CAMINO REAL CARLSBAD PREMIER OUTLETS COMPLETE OFFICE BUILDING OTHER: PCR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: KATHLEEN LAWRENCE DATE:03/25/14 REMARKS: NO ADDITIONAL ENG FEES SEE CB07-876 FOR OFFICE Tl E-36 Notification of Engineering APPROVAL has been sent to KRATTE@DESIGNCORPSD.COIVI via EMAIL on 03/25/14 Page 1 of 1 REV 4/30/11 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: K LAWRENCE Date: 03/25/14 GEO DATA: LFMZ: / B&T: Acidress; 2177 SALK #200 BIdg. Permit #; CB14-0542 Fees Update by: KML Date: 03/25/14 Fees Update by: Date; 03/25/14 EDU CALCULATIONS: List types and square footages for all uses. Types of Use: OFFICE Sq.Fl/Units 11,428 SF EDU's; 4.06 Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use; Sq.Ft./Units EDU's: ADT CALCULATIONS: List types and square footages for all uses. Types of Use; OFFICE Sq.Ft./Units 11,428 SF ADT's; 171 Types of Use; Sq.Ft./Units ADT's: Types of Use; Sq.Ft./Units ADT's; Types of Use; Sq.Ft./Units ADTs: FEES REQUIRED; Within CFD; YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) NO 1. PARK-IN-LIEU FEE; NW QUADRANT NE QUADRANT SE QUADARANT SW QUADRANT ADT'S/UNITS; X FEE/ADT: =$ N/A • 2.TRAFFIG IMPACT FEE; • ADT'S/UNITS: 171 X FEE/ADT; $97 =$ 16,587 3. BRIDGE & THOROUGHFARE FEE; • DIST. #1 DIST,#2 DIST.#3 ADTS/UNITS: < FEE/ADT; =$ N/A • 4. FACILITIES MANAGEMENT FEE ZONE: • ADT'S/UNITS: X FEE/SQ.FT./UNIT; =$ N/A • 5. SEWER FEE EDU's 4.06 X FEE/EDU; 842 =$ 3418.52 BENEFIT AREA: F EDU's 4.06 X FEE/EDU; 3134 =$ 12724.04 0 6. DRAINAGE FEES; PLDA; HIGH MED UM LOW ACRES; X FEE/AC; =$ N/A U 7. POTABLE WATER FEES; UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL yf'»• PLANNING DIVISION Development Services Planning Division yf'»• BUILDING PLAN CHECK Development Services Planning Division CITY OF APPROVAL 1635 FaradayAvenue CARLSBAD P-29 (760) 602-4610 www.carlsbadca.eov DATE: 3-11-14 PROJECT NAIVIE: PROJECTID: PLAN CHECK NO: PC 14-06 SET#: 1 ADDRESS: 2177 Salk Av APN: 212-021-03-00 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No Vou may also have corrections from one or more of the divisions Usted below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or Incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: kratte@deslgncorpsd.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.fiov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.fiov Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.fiQV 1 1 Gina Ruiz 760-602-4675 Gina.Rulz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Llnda.Ontiveros@carlsbadca.gov Q Cindy Wong 760-602-4662 Cvnthla.Wonfi@carlsbadca.gov • 1 1 Dominic Fieri 760-602-4664 Domlnic.Flerl@carlsbadca.gov Remarks: ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL BUILDING DEFt Co^Qliity'& Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 04/12/2014 PLAN CHECK NO: 2 SET#: 1 PROJECT NAME: CALAMP PROJECT ID: PC140006 ADDRESS: 2177SALKAV STES 100 & 200 APN: Kl • This plan check review is complete and has been APPROVED by the FIRE Division. By: GR A Final Inspection by the FIRE Division is required ^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: K. RATTE-VALENTE - DESIGNCORP You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: • • — •• • -—• • • : • ENGINEERING FIRE PREVENTION 760-602-2750 760-6024665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.jSov X Gfeg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.fiov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: See Attached BUILDING DEP Carlsbad Fire Department f-r^P^ * Plan Review Requirements Category: PLANCK, Date of Report: 04-12-2014 Reviewed by: Name: VALENTE KIM Address: 4944 COLLINGWOOD DR SAN DIEGO CA 92109-2243 Permit #: PC140006 Job Name: CALAMP Tl - 22,501 SF TOTAL // Job Address: 2177 SALK AV CBAD Please review carefully all comments attached. Conditions: CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: w/ REQUIREMENTS. THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. 1. Provide fire extinguisher in wall cabinet on outside wall of Room 119 facing 113/124. 2. Provide a 2A:10BC fire extinguisher inside of Rooms 207 and 209. 3. Relocate the EXIT sign outside of Office 106 to outside of Office 104 and change orientation so that it is facing Office 108. 4. Relocate Double-faced EXIT sign in Open Office 108 closer to towards Corridor 126 so it is in line with the EXIT sign outside of 104. 5. Add single face EXIT sign in Corridor 228 at the edge between Office 224 and Server/Storage 207/208 facing Open Office 201/202. 6. Change EXIT sign outside of 218 to Double-faced sign. 7. Add Double-faced EXIT sign outside of 211 with arrows towards Corridor 210. 8. Relocate EXIT sign in 201 toward exterior wall so it is in line with the E-sign outside of 218. 9. At or prior to Final Fire and Building inspection an Emergency lighting facilities test shall be conducted by CFD personnel during pre-dawn or dusk hours when ambient light is at 0.00 Lux or 0.0 Foot-candle. This test shall be conducted to test the initial loss of power reading of illumination that is at least an average of 1 foot candle (11 lux) and a minimum of 0.1 foot-candle (1 lux) measured along the path of egress at the floor level. And tested after 60-minutes to 0.6 fc (6 lux). Failure to provide sufficient lighting in egress aisles, corridors, exit enclosures, exit passageways and stair enclosures is the AOR's responsibility. CFC Ch. 10, Sec. 1006. ALL OF THE ABOVE ITEMS SHALL BE FIELD VERIFIED. Entry: 04/12/2014 By:GR Action: AP BLDG. DEPT COPY " RECOMMENDATION FOR APPROVAL Daryl K. James & Associates, Inc. Checked by: Matthew Ernau Date: 3/29/2014 APPLICANT: Kim Valente JURISDICTION: Carlsbad Fire Department PROJECT NAME: CalAmp PROJECT ADDRESS: 2177 Salk ave Suite 100 & 200 PROJECT DESCRIPTION: PC140006 INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. YOUR PHOTOMETRIC PLAN OF ALL OCCUPIED AREAS THAT DEMONSTRATE COMPLIANCE WITH CBC 1006, AND WILL BE REVIEWED BY THE CARLSBAD FIRE DEPARTMENT, DEPUTY FIRE MARSHAL GREG RYAN (760 602-4665) TS TI-1.1.1 In Finishes notes section change reference to 2010 CBC to 2013 OK In Fire Protection notes section #12 change reference to 2010 CFC to 2013 OK In general notes section improvements shall comply with 2013 CBC not 2010 OK • Provide a note fire extinguisher location and size to be in accordance with CFC OK • Provide detailed description of what Lab room is being used for. OK TI-1.1.2 • You show card readers being used through-out. Provide a detailed descriptive narrative of card reader and how loss of power to the building affects the ability to open a door from the egress side without the use of a key, special effort or knowledge. Address the requirements of CFC 2013 section 1008.1.4.4. OK TI-1.2.2 E-1.1 • You show card readers being used through-out. Provide a detailed descriptive narrative of card reader and how loss of power to the building affects the ability to open a door from the egress side without the use of a key, special effort or knowledge. Address the requirements of CFC 2013 section 1008.1.4.4. OK • In reflected ceiling legend include a description and a symbol for emergency lighting including directional type being used include in description must provide 90 minutes battery • back-power. You show symbol on lighting plan EM but you do not show same in legend.OK • In notes section add a note that states: existing exit signs and emergency lighting has been tested and provides 90 minutes of battery backup OK E-1.2 M-2.1 Page 2 of 2 In notes section add a note that states; existing exit signs and emergency lighting has been tested and provides 90 minutes of battery backup OK In reflected ceiling legend include a description and a symbol for emergency lighting including directional type being used include in description must provide 90 minutes battery back-power. You show symbol on lighting plan EM but you do not show same in legend. OK Add this note stating air-moving systems supplying air in excess of 2000cfm equipped with Smoke detectors approved and listed by the State Fire Marshal and design using 2013 CFC and 2013 NFPA 72 OK PC Comments Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Page:jLof2 BLDG. DEPT CO^Y Checked by: Matthew Ernau Date: 3/23/2014 APPLICANT: Kim Valente JURISDICTION: Carlsbad Fire Department PROJECT NAME: CalAmp PROJECT ADDRESS: 2177 Salk ave Suite 100 & 200 PROJECT DESCRIPTION: PCI40006 INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. • The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. • To expedite the recheck process, please note on this list (or copy) how and where each correction item has been addressed, i.e. sheet number, note number, detail number, legend number, etc Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates.. • Please direct any questions regarding this review to: Matthew Ernau 760-738-8279 or emau57@cox.net • CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWiNG EACH COMMENT ON THIS FORM, AND A COPY OF BUILDING DEPARTMENT (EsGii) COMMENTS MUST BE SUBMITTED DIRECTLY TO: " Matthew Ernau 1382 Hale Ave Escondido, CA 92029 IF PLANS ARE NOT SENT OR DELIVERED DIRECTLY TO THE ADDRESS ABOVE RECOMMENDATION FOR APPROVAL COULD BE DELAYED YOUR PHOTOMETRIC PLAN OF ALL OCCUPIED AREAS THAT DEMONSTRATE COMPLIANCE WITH CBC 1006, AND WILL BE REVIEWED BY THE CARLSBAD FIRE DEPARTMENT, DEPUTY FIRE MARSHAL GREG RYAN (760 602-4665) TS In Finishes notes section change reference to 2010 CBC to 2013 In Fire Protection notes section #12 change reference to 2010 CFC to 2013 In general notes section improvements shall comply with 2013 CBC not 2010 2of 2 TI-1.1.1 TI-1.1.2 TI-1.2.2 E-1.1 E-1.2 M-2.1 Provide a note fire extinguisher location and size to be in accordance with CFC Provide detailed description of what Lab room is being used for. You show card readers being used through-out. Provide a detailed descriptive narrative of card reader and how loss of power to the building affects the ability to open a door from the egress side without the use of a key, special effort or knowledge. Address the requirements of CFC 2013 section 1008.1.4.4. You show card readers being used through-out. Provide a detailed descriptive narrative of card reader and how loss of power to the building affects the ability to open a door from the egress side without the use of a key, special effort or knowledge. Address the requirements of CFC 2013 section 1008.1.4.4. In reflected ceiling legend include a description and a symbol for emergency lighting including directional type being used include in description must provide 90 minutes battery back-power. You show symbol on lighting plan EM but you do not show same in legend. In notes section add a note that states: existing exit signs and emergency lighting has been tested and provides 90 minutes of battery backup In notes section add a note that states: existing exit signs and emergency lighting has been tested and provides 90 minutes of battery backup In reflected ceiling legend include a description and a symbol for emergency lighting including directional type being used include In description must provide 90 minutes battery back-power. You show symbol on lighting plan EM but you do not show same in legend. Add this note stating air-moving systems supplying air in excess of 2000cfm equipped with Smoke detectors approved and listed by the State Fire Marshal and design using 2013 CFC and 2013 NFPA 72 Orie Engineering stmctural & Bridge Engineers 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone: (858) 335-7643 Fax: (858) 586-0911 Structural Calculations PROJECT: CalAmp at 2177 Salk, Carlsbad - Suspended Transformers (Project* 185.005-14) CLIENT: Designcorp. DESIGNED BY: DJF DATE: 3/26/14 Orie' - Structural Engineers Page: 1 Orie' Engineering Structural & Bridge Engineers Project No.: 185.005-14 9750 Miramar Road, Suite 310 San Diago, CA 92126 Phone #: (858) 335-7643 PROJECT : CalAmp al 2177 Salk DATE: BY: 03/26/14 DJF Anchor«o» of Ham TfiinfonnOTS (2) "P1000" UNISTRUr • w/ (2) 3/8" K 3" WG SCRB#S TO BIK'G. EA. UNISIRUT (E) PLYVKOOD DECK (E) TJI JOBT UNBTRt/T ^1546' *NGl£ FimNG. TirP w/ 3/8" MA X 3" lAG SCREW 4x4 BU<"G »/ "U" HANGER EA END 2x4 FU£R w/ (2) 1/2' WA THRU-eaTS 1/8" AIRCRtfT CABLE. TYP SEE "CABII BRACMG PUN" SECURE ENDS TO T1546" UNBIRUT "P1546" ANGLE nn)NG w/NUTS EA SIDE TO SB:URE 1/2" DIA A307 ALL-THREAD, TOT. 4 "PI 000' UNISTRUr TYP. OF (2) CHANNa NUT, TYP.- T&B ELEVATION \ (4) 1/2" A307 BOLTS w/CHANNa NUTS TO SECURE TRANSFORMER y TO UNBTRUT ^,2) K100U UNISIKUl w/ (2) 3/8" X 3" LAG SCREWS TD aK'G. EA UNISTRUT (E) PLYWOOD DECK 4x4 BLK'G w/ "U" HANGER EA END t/8" AIRCRAH CABLE, TYP, SEE XABLE BRACING PLAN' SECURE ENDS TO "P1546* UNISTRUT "P1546" ANaE FTrriNG w/NUIS EA SIDE TO SECURE 1/2" DIA A307 Aa-THREAD. TOT. 6 •PIOOO" UNISTRUT TYP. OF (2) CHANNEL NUT, TYP.- T&e ELEVATION (4) 1/2" A307 BOLTS x/CHANNa NUTS TO SECURE TRANSFORMER rO UNISIRUT 9750 Miramar Road, Suite 310 San Diego, CA 92126 Orte Engineering Stmctural & Bridge Engineers Piione #: (858) 335-7643 Project No.: 185.005-14 PROJECT : CalAmp at 2177 Salk DATE: BY: Page: 2 03/26/14 DJF Anchorage of New TratMfermera "tZJ KIOOO UNiSiKUi tr/ (2) 3/8" X 3" LAG SCREWS TO BLK'G. EA UNISTRUT (E) PLYWOOD DECK 4x4 BLK'G w/ "U" HANGER EA END 1/8* ARCRAn CABLE, TlTP. SEE 'CABLE BRACING PLAN' SECURE ENDS TO "PI 546" UNISTRUT "PI 546" ANaE FTTTING w/NUTS EA SIDE TO SECl«E CHANNa NUT. TYP.' T&S ELEVATION (4) 1/2" A307 BOLTS w/CHANNEL NUTS TO SECURE TRANSFORMER TO UNISTRUT 1/2" DIA A307 Aa-THREAD, TOT. 6 "PIOOO* UNISTRUT TYP. OF (2) Fp= C>.n * (3'2-S*K'2,"^ * l\|'tt* it t^p /t, <it>\' 9750 Miramar Road, Suite 310 San Diago, CA 92126 Orie Engineering Sbuctural & Brklge Engineers Plwne*: (858) 335-7643 Project No.: 185.005-14 PROJECT : CalAmp at 2177 Salk DATE: BY: Page: 3 03/26/14 DJF AnctwfiOT gf Ntw Tmntfefiwii A ^t^DS Tt>v WW 9750 Miramar Rd., Suite 310 San Diego, CA 92126 Orie Engineering Structural & Bridge Engineers Phone #: (858) 335-7643 Page: 4 JOB #: 18S.005-14 PROJECT : CalAmp at 2177 Salk DATE: 03/26/14 DESCRIPTION : Transformer Anchorage DESIGNED : DJF ' Equipment Anchorage (per 2013 CBC)' Description: Transformer Anchorage Suspended below 2nd FL I Input I •7-10 Code: 2013 CBC/ASCE 7-0S\CHAPTER 11,12,13 SEISMIC DESIGN CRITERIA I Stte Class: D Zip Code: (San Diego) S.: 108.7000 %g Si: 41.2000 %g F.: 1.0650 F,: 1.5880 SMS: 1.1577 SMV 0.6543 Soj: 0.7718 SDV 0.4362 Occupancy: II lp:1 Component = Transformer ap • 1 Rp ' 2.5 z« 13.5 h« 30 Table 20-3-1, Default = D (USGS using Latitude/Longttude) Seismic Force: Fp - 0.4apSDsWp 0.2346 xWp Fp,mlii * 0.3SDSIP xWp Fp,i»ln • 0.2315 xWp Fp,|MX * 1.6SDSIP xWp 1.2348 xWp 0.2346 xWp Table 11.4-1 Table 11.4-2 F.-S. F/S, 2/3(S„s) 2/3(S„i) * Read Requirements 13.1.3 Table 13.5-1 or 13.6-1 x(1+2(z/h)) <- Governs Page: 5 Orie' Engineering stmctural & Bridge Engineers Project No.: 185.005-14 9750 Miramar Road, Suite 310 San Diego, CA 92126 Phone #: (858) 335-7643 PROJECT: CalAmp at 2177 Salk DATE: BY; 03/26/14 DJF Aircraft Cable Diameter Approx. Weight Per 1000 Ft (lbs) Galvanized n/linimum Breaking Strength (lbs) Stainless Minimum Breaking Strength (lbs) 3/M" 4.2 270 270 1/16" 7.5 480 480 3/32' 16 920 ^ 920 1/8" 28 5/32" 43 2,600 ^ ^ 2,400 3/16" 62 3,700 3,700 1/4" 106 6,100 6,100 5/16" 167 9,200 9,000 3/8" 236 13,100 12,000 7X7 Diameter Approx. Weight Per 1000 Ft. (lbs) Galvanized Minimum Breaking Strength (lbs) Stainless Minimum Breaking Strength (lbs) 3/32" 17.4 l,0O0 920 1/8" 29 2,000 1,760 5/32" 45 2,800 2,400 3/16" 65 4,200 3,700 7/32" 86 5,600 5,000 7X19 1/4" 110 7,000 6,4O0 5/16" 173 9,800 9,000 3/8" 243 14,400 12,000 Diameter Approx. Weight Per 1000 Ft. (lbs) Galvanized Minimum Breaking Strength (lbs) Stainless Minimum Breaking Strength (lbs) 3/64" 5.5 375 375 1/16" 8.5 SOO 500 3/32" 20 1,200 1,200 1/8" 35 2,lO0 2,100 5/32" 55 3,300 3,300 3/16" 77 4,7O0 4,700 7/32" 102 6,300 6,300 1/4" 135 8,2O0 8,200 1X19 9/32" 170 10,300 10,30O 5/16" 210 12,500 12,500 3/8" 300 17,500 17,500 7/16" 410 22,500 22,500 1/2" 521 30,000 30,000 9/16" 670 36,200 36,200 5/8" 855 47,000 47,O0O GROUPB 480 DELTA PRIMARY VOLTS — 208Y/120 SECONDARY VOLTS MAY BE USED ON A 4 WIRE 480Y/277 VOLT SUPPLY — 30,60 Hz -^.Page: 7 'Listed and Q(®Certified KVA CATALOG No. APPROX. DIMENSIONS (Inches) APPROX. SHIP WEIGHT TYPE MTG. W-Wall F-Floor Knockouts Weather Shiekl P/N Electrical Connections See Page 37 Design Figure See Page 23 KVA CATALOG No. Height Width Depth APPROX. SHIP WEIGHT TYPE MTG. W-Wall F-Floor Knockouts Weather Shiekl P/N Electrical Connections See Page 37 Design Figure See Page 23 3.0 T-2-53308-1S 12.45 17.62 5.28 75 F&W %-1 NA 20 F 6.0 T-2-53309-1S 14.69 17.68 7.15 140 F&W v^-^ NA 20 F 9.0 T-2-53310-1S 14.69 21.68 7.15 180 F&W NA 20 F 15.0 T-2-53311-1S 16.18 22.62 9.84 250 F&W V2-1 NA 21 F ^5.0^ J-1M3393-3§_ ^3.72 26.31 21.75 E*. NA WS-A-62 22 J 30.0 T-1A-53312-3S 23.72 j 26.31 1 21.75 325 J F-NA W"§^A-62 22 J 1 •—37r" TlA-53^-3S" 26.41 27.31 22.94 4D0 NA WS-A-63 22 45.0 T-1A-53313r3S 26.41 27.31 22.94 400 F" NA WS-A-63 22 I 50.0 T-1A-53403r3S 30.38 32.31 27.19 600 F* NA WS-A-64 22 1 75.0 T-1A-53314t3S 30.38 32.31 27.19 600 F* NA WS-A-64 22 1 112.5 T-1A-53315^3S 34.63 35.31 29.50 750 F NA WS-A-65 22 1 150.0 T-1-53316-3S 42.00 40.00 30.00 1125 F NA WS-A-53 23 E 225.0 T-1-53317-3S 54.00 45.00 30.00 1675 F NA WS-A-54 23 E 300.0 T-1-53318-3S 56.00 48.00 40.00 1920 F NA WS-B-2 23 G 500.0 T-1-53319-3S 62.00 54.00 42.00 2675 F NA WS-B-3 23 G 1 750.0 T1A-53321H3S 86.00 72.00 60.00 4425 F NA 23 G 5 IV 'Wall mounting brackets are available for these sizes, reter to page 25. GROUPC NON-VENTILATED TRANSFORMERS 480 DELTA PRIMARY VOLTS—208Y/120 SECONDARY VOLTS MAY BE USED ON A 4 WIRE 480Y/277 VOLT SUPPLY—30,60 Hz KVA CATALOG No. APPROX. DIMENSIONS (Inches) APPROX. SHIP WEIGHT TYPEMTQ. W-Wall F-Ftoor Knockouts Weather Shield P/N Electrical Connections Seepages? Design Figure See Page 23 KVA CATALOG No. HeigM WMth Depth APPROX. SHIP WEIGHT TYPEMTQ. W-Wall F-Ftoor Knockouts Weather Shield P/N Electrical Connections Seepages? Design Figure See Page 23 30.0 TE-1-53312-3S 30.00 27.00 21.50 405 r NA NA 22 H 45.0 TE-1-53313^ 34.00 33.00 23.25 565 p NA NA 22 H 75.0 TE-1-53314-^ 42.00 40.00 30.00 800 F NA NA 22 H 112.5 TE-1-53315-3S 42.00 40.00 30.00 1120 F NA NA 23 H 150.0 TE-1-6331ft3S 54.(K) 45.00 30.00 1475 F NA NA 23 H 'Wall mounting brackets are available for ttiese sizes, refer to page 2S. Design F Design G | ^ BUILDING ENERGY ANALYSIS REPORT PROJECT: CalAmp VR Suite 100 2177 Salk Ave Carlsbad, CA 95800 Project Designer: Designcorp 4944 Collingwood Dr. San Diego, CA 92109 Report Prepared by: Tom Harinton HARINTON MECHANICAL DESIGN INC 27475 Ynez Rd #246 Temecula, CA 92591 858-435-4803 Job Number: Date: 3/4/2014 The EnergyPro computer program has been used to perform the calculations summarized In this compliance report. This program has approval and Is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC -www.energysoft.com. EnergyPro 5.1 by EnergySoft User Numtier: 4945 RunCode: 2014^3-04711:56:54 ID: TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form ENV-1-C Certificate of Compliance 3 Form ENV-3-C Overall Envelope TDV Approach 8 Form MECH-1 -C Certificate of Compliance 12 Form MECH-2-C Air & Water System Requirements 21 Form MECH-3-C Mechanical Ventilation 25 Form MECH-4-C HVAC Misc. Prescriptive Requirements 27 Form MECH-MM Mechanical Mandatory Measures 37 HVAC System Heating and Cooling Loads Summary 38 EnergyPro 5.1 by EnergySoft Job Number: ID; User Number: 4945 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKUST (Parti of4) ENV-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: Gl Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) Relocatable Public School 12 Conditioned Spaces • Unconditioned Spaces • Skylight Area for Large Enclosed Space > 8000 ft (If checl<ed include the ENV-4C with submittal) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component • Overall Envelope • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: Odeg FIELD INSPECTION ENERGY CHECKLIST OPAQUE SURFACE DETAILS INSULATION Tag/ID Assembly Type < 2^ |OT" 4) uT o 0) UEC o •Z tt 0) 3 Pa Ul > K 3 IU U. OC O £> it n K •a c 1 8. a tit TJ 3 o S U OT w tn CD D. Slab 610 (N) 0.730 None 4.4.7-A1 New Wall 540 (N) 0.226 None 7.0 Metal 4.3.6-D5 Existing Slab 1,080 (N) 0.730 None 4.4.7-A1 New • Wall 162 (N) 0.226 None 7.0 Metal 4.3.6-D5 Existing Wall 696 (E) 0.226 None 7.0 Metal 4.3.6-D5 Existing Slab 307 (N) 0.730 None 4.4.7-A1 New Wall 150 (SE) 0.226 None 7.0 Metal 4.3.6-D5 Existing Wall 288 (N) 0.226 None 7.0 Metal 4.3.6-D5 Existing Slab 1,687 (N) 0.730 None 4.4.7-A1 New 10 Slab 1,185 (N) 0.730 None 4.4.7-A1 New 1. See Instructions In the Nonresidential Compliance Manual, page 3-96. 2. If Fail, then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. A fail does not meet compliance. FENESTRATION SURFACE DETAILS Tag/ID Fenestration Type ra £ < Orientation N, E, S, W Max U-Factor U-Factor Source Max (R)SHGC SHGC Source Overhang Conditions Status Pass N *« 11. 1 Window 366 (N) 0.710 Default 0.240 COG • Existing • • 2 Window 336 (E) 0.710 Default 0.240 COG • Existing • • 3 Window 48 (SE) 0.710 Default 0.240 COG • Existing • • 4 Window 424 (W) 0.710 Default 0.240 COG • Existing • • • • • • • • • • • • • • • • • • • • 1. See Instructions in the Nonresidential Compliance Manual, page 3-96. 2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 3 of 47 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKUST (Parti of4) ENV-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: • Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) Relocatable Public School BIdg. Bl Conditioned Spaces • Unconditioned Spaces • Skylight Area for Large Enclosed Space s 8000 ft (If checked include the ENV-4C with submittal) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component • Overall Envelope • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: Odeg FIELD INSPECTION ENERGY CHECKUST OPAQUE SURFACE DETAILS INSULATION Tag/ID Assembly Type SOT u LU tt >. = l> CO I o k tt tt 3 IU > o o> tt ^ UJ u. « ^ £ u. •a c .sS. £ M •a 3 O Si U OT « a Q. a u. 11 12 Wall 384 (W) 0.226 None 7.0 Metal 4.3.6-D5 Existing Slab 725 (N) 0.730 None 4.4.7-A1 New 13 14 15 16 17 18 Wall 462 (W) 0.226 None 7.0 Metal 4.3.6-D5 Existing Slab 1,880 (N) 0.730 None 4.4.7-A1 New Slab 745 (N) 0.730 None 4.4.7-Al New Wall 680 (W) 0.226 None 7.0 Metal 4.3.6-D5 Existing Slab 1,390 (N) 0.730 None 4.4.7-A1 New Slab 1,653 (N) 0.730 None 4.4.7-A1 New 1. See Instructions in the Nonresidential Compliance Manual, page 3-96. 2. If Fail, then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. A fail does not meet compliance. FENESTRATION SURFACE DETAILS Tag/ID Fenestration Type < Orientation N, E, S, W Max U-Factor U-Factor Source Max (R)SHGC SHGC Source Overhang Conditions Status Pass en '(5 u. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1. See Instructions in the Nonresidential Compliance Manual, page 3-96. 2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 4 of 47 CERTiFiCATE OF COMPLIANCE (Part 2 of 4) ENV-1 C AND FIELD INSPECTION ENERGY CHECKUST Project Name CalAmp VR Suite 100 Date 3/4/2074 ROOFING PRODUCT (COOL ROOFS) (Note if the roofing product is not CRRC certified, this compliance approach cannot be used). Go to Overall Envelope Approach or Performance Approach. CHECK APPLICABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENTS: Pass Fali^ N/A • Roofing compliance not required in Climate Zones 1 and16 with a Low-Sloped. 2:12 pitch or less. • • • Q Roofing compliance not required in Climate Zone 1 with a Steep-Sloped with less than 5 Ib/tt^. Greater than 2:12 pitch. • • • p. Low-sloped Wood framed roofs in Climate Zones 3 and 5 are exempted, solar reflectance and thermal emittance or ^ SRI that have a U-factor of 0.039 or lower. See Opaque Surface Details roof assembly. Column H of ENV-2C. • • • Low-sloped Metal building roofs in Climate Zone 3 and 5 are exempted, solar relectance and thermal emittance or SRI that have a U-factor of 0.048 or lower. See Opaque Surface Details roof assembly below, Column H of ENV-2C. • • • p. The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempted. Solar reflectance and thermal emittance or SRI, see spreadsheet calculator at www.enerav.ca.aov/title24/ • • • n Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 W aire exempt from the Cool Roof criteria below. • • • p. High-rise residential buildings and hotels and motels with low-sloped roofs in Climate Zones 1 through 9,12 and 16 are exempted from the low-sloped roofing criteria. • • • 1. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. CRRC Product ID Number' Roof Slope s 2:12 >2:12 Product Weight < 5lb/ft^ i 5lb/ft^ Product Type^ Aged Solar Reflectance' Thermal Emmitance SRI= Pass Fail^ • • • • • • • • • • n* • • • • • • • • • • • • • • • • • • • • • • • • • • 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.ora/Droducts/search.php 2. Indicate the type of product is being used for the roof top, i.e. single-ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same directory and use the equation (0.2+0.7(pinitiai - 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance from the Cool Roof Rating Council's Rated Product Directory. 4. Check t>ox if the Aged Reflectance is a calculated value using the equation above. 5. The SRI value needs to be calculated from a spreadsheet calculator at http://www.enerav.ca.aov/title24/ 6. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating: • Aluminum-Pigmented Asphalt Roof Coating • Cement-Based Roof Coating • Other Discrepa tides: EnergyPro 5.1 bv EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 5 of 47 CERTIFICATE OF COMPLIANCE (Part 3 of 4) ENV-1 C AND FIELD INSPECTION ENERGY CHECKLIST (Part 3 of 4) Project Name Date CalAmp VR Suite 100 3/4/2014 Required Acceptance Tests Designer: This fornn is to be used by the designer and attached to the plans. Listed below is the acceptance test for Envelope Fenestrations system. The designer is required to check the acceptance tests and list aii the fenestration products that require an acceptance test. If all the site-built fenestration of a certain type requires a test, list the different fenestration products and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices iVIanual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of worl^ appropriately. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or whenever new fenestration is installed in the building or space shall be certified as meeting the Acceptance Requirements. The ENV-2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checiced and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, instaiiation certificates, and operating and maintenance information meet the requirements of §10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the ENV-2A for each different fenestration product line must be provided to the owner of the building for their records. Test Description ENV-2A Test Performed By: Fenestration Products Name or ID Requiring Testing or Verification Area of like Products Building Envelope Acceptance Test • • • • • • EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 6 of 47 CERTIFICATE OF COMPUANCE AND FIELD INSPECTION ENERGY CHECKUST (Part 4 of 4) ENV-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone CA Climate Zone 07 Total Cond. Floor Area 11,262 Addition Floor Area n/a Documentation Author's Declaration Statement I certify that this Certificate of Compliance documentation is accurate and complete. Name Tom Harinton Signature ^jj/^dJ^auri^ Company HARINTON MECHANICAL DESIGN INC Date 3/4/2014 Address 27475 Ynez Rd #246 CEA# CEPE# City/State/Zip Temecula, CA 92591 Phone 858-435-4803 The Principal Envelope Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the envelope design. • This Certificate of Compliance identifies the envelope features and performance specifications required for compliance with Title-24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name Signature Company Designcorp Date Address 4944 Collingwood Dr. License # City/State/Zip San Diego, CA 92109 Phone Envelope Mandatory Measures Indicate location on building plans of Mandatory Envelope Measures Note Block:. INSTRUCTIONS TO APPLICANT ENVELOPE COMPLIANCE & WORKSHEETS (checit box if worksheet Is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the 2008 Nonresidential Manual published by the California Energy Commission. ENV-1 C Certificate of Compliance. Required on plans for all submittals. • ENV-2C Use with the Envelope Component compliance approach. Optional on plans. • ENV-3C Use with the Overall Envelope compliance approach. Optional on plans. • ENV-4C Prescriptive compliance for the minimum skylight requirements for large enclosed spaces in climate zones 2 through 15. Optional on plans. EnergyPro 5.1 bv EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 7 of 47 OVERALL ENVELOPE TDV ENERGY APPROACH (Part 1 of 6 ) ENV-3C Project Name CalAmp VR Suite 100 Date 3/4/2014 WINDOW RATIO CALCULATION for ALL WALLS A. Total linear display perimeter 0 ftX6ft 0ft2 Display Area B. Total Gross Exterior Wall Area 4,536 ft^ X 0.40 = 1,814 f|2 40% of Gross Exterior Wall Area C. Enter Larger of A or B 1,814 f^2 Maximum Standard Area D. Enter Proposed Window Area 1.174 ^ Proposed Area If the proposed Window Area is greater than the Maximum Standard Area, then the envelope component method may not be used. E. Window Wall Ratio = (Row D) Divided by (Row B) 25.88 % See RSHG in Table 143-A, 143- B, or143-C WEST WINDOW RATIO CALCULATION F. West Linear Display 0 ftX6ft 0 ft2 West Display Area G. West Exterior Wall Area 1,950 ft^ X 0.40 = 780 ^2 40% of West Exterior Wall Area H. Enter Larger of F or G 780 ft2 Maximum Standard West Area 1. Enter Proposed West Window Area 424 f^z Proposed West Window Area If the proposed West Window Area is greater than the Maximum Standard West Area, then the envelope component method may not be used. J. Window Wall Ratio = (Row I) Divided by (Row G) 21.74% See West RSHG in Table 143-A, 143-B, or143-C COMBINED AREA FOR NORTH, EAST AND SOUTH WALLS K. N/E/S Display Perimeter (A Minus E) 0 ftX6ft Oft^ N/E/S Of West Exterior Wall Area L. N/E/S Exterior Wall Area (B Minus G) 2,586 ft^ X 0.40 = 1,034 1^2 40% N/E/S Area M. Enter Larger of K or L 1,034 ^2 Maximum Standard N/E/S Area N. Proposed N/E/S Window Area (D Minus 1) 750 ^2 Proposed N/E/S Area WINDOW ADJUSTMENT O. If D > C and/or if I > H, proceed to the calculation steps 1 for all walls or 2 for west wall. If not, go to the skylight area test on page 6. 1. If D > C: Use the calculated Window Adjustment Factor (WAR) for ail walls. PROPOSED WINDOW MAX. STANDARD AREA AREA (from C) (from D) WINDOW ADJUSTMENT FACTOR Go to Page 6 to calculate Adjusted Area 2. If I > H: Calculate one Window Adjustment Factor (WAF) for the West wall. MAX. STANDARD WEST PROPOSED WEST AREA AREA (from H) (from I) WEST WINDOW ADJUSTMENT FACTOR MAX. STANDARD AREA (from C) PROPOSED AREA (from D) WEST WINDOW ADJUSTMENT FACTOR Go to Page 6 to calculate Adjusted Area EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 8 of 47 OVERALL ENVELOPE TDV ENERGY APPROACH (Part 2 of 6 ) ENV-3C Project Name CalAmp VR Suite 100 Date 3/4/2014 SKYLIGHT RATIO CALCULATION §143(b) Actual Gross Roof Area Maximum Allowed Standard Skylight Area A. If Atrium/Skylight Height is S 55 ft; or 0 ft^ X 0.05 0„2 B. If Atrium/Skylight Height is > 55 ft ft^XO.10 ft^ C. Proposed Skylight Area ^ft^ D. Skvliaht Ratio = Proposed Skvliaht Area (Row C) Divided bv Actual Gross Roof Area 0.0 % SRRprop E. Maximum Allowed Skylight Roof Ratio = Maximum Allowed Standard Skylight Area (Row A or B) Divided by Total Gross Exterior Roof Area 5 % SRRsTD IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PAGE 3 OF 6. SKYLIGHT AREA ADJUSTMENT IF F > D, Proceed To Calculation Step 1 Step 1. Calculated the Skylight Adjustment Factor (WAF). STANDARD SKYLIGHT AREA PROPOSED SKYLIGHT AREA (IF E = 0 ENTER 1) SKYLIGHT ADJUSTMENT FACTOR (SAF) CARRY THE WINDOW ADJUSTMENT FACTOR (SAF) TO PAGE 6 OF 6 TO CALCULATE THE ADJUSTED AREA EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 9 of 47 OVERALL ENVELOPE TDV ENERGY APPROACH (Page 3 of 6) ENV-3C Project Name CalAmp VR Suite 100 Date 3/4/2014 Climate Zone 7 TDV for the Standard Design Building, See Reference Nonresidential Appendix NA5-2 Occupancy Type and Coefficients Tables H Nonresidential, See Table NA5-3 • 24-Hour Use, See Table NA5-4 • Retail, See Table NA5-5 A B c D E F G H J K L M Assembly Type' Orientation Number Of Uke Assembly Type" Roofs or Floor Mass Type= Exterior Surface Area Penetration Type Criteria Coefficients for* Standard TDV Energy'" Assembly Type' Orientation Number Of Uke Assembly Type" Roofs or Floor Mass Type= Exterior Surface Area Penetration Type Criteria U-factor SHGC VT Standard TDV Energy'" Assembly Type' Orientation Number Of Uke Assembly Type" Roofs or Floor Mass Type= Exterior Surface Area Penetration Type U-factor^ SHGC' VT» CSu.i CSs.i Cs,./ Standard TDV Energy'" Wall N Medium 540 0.440 11.97 2,844 Window N 1 240 Site-built 0.770 0.610 0.732 4.97 151.32 0.67 23,r89 Wall N 1 Medium 162 0.440 11.97 853 Window N 1 78 Site-built 0.770 0.610 0.732 4.97 151.32 0.67 7,537 Wall E 1 Medium 696 0.440 11.97 3,666 Window E 1 336 Site-built 0.770 0.390 0.468 1.81 279.82 5.40 37,985 Wall E 1 Medium 150 0.227 11.97 408 Window E 1 48 Site-built 0.470 0.360 0.432 1.81 279.82 5.40 4,988 Wall N 1 Medium 288 0.227 11.97 783 Window N 1 48 Site-built 0.470 0.610 0.732 4.97 151.32 0.67 4,566 Wall W 1 Medium 384 0.440 11.97 2,022 Window W 1 144 Site-built 0.770 0.390 0.468 2.92 348.89 1.89 20,045 Wail W 1 Medium 462 0.440 11.97 2,433 Window W 1 240 Site-built 0.770 0.390 0.468 2.92 348.89 1.89 33,408 Wall W 1 Medium 680 0.440 11.97 3,581 Window W 1 40 Site-built 0.770 0.390 0.468 2.92 348.89 1.89 5,568 Sum of Total Standard Design 153,876 1. Indicate type of assembly for the Envelope (e.g. Wall, Floor, Roof, Window, Skylight & Door). One assembly type for each row. 2. Enter the area of each different assembly. 3. Enter the type of fenestration; M = Manufactured, SB = Site-built, SK = Skylight and F = Fabricated. 4. Grouping of like assemblies in the same orientation is allowed. Indicate the number in column E. 5. Enter Roofs, Floors, Walls and for Mass Walls the catergoies are; light (HC < 7), medium mass (7 i HC,15), and heavy mass (HC > 15). 6. Standard Design U-factor are from Table 143-A, B or C. 7. Standard Design SHGC are from Table 143-A, B or C. Enter "0" if not applicable. Note: Not all vertical windows have an overhang then assume SHGC as value entered. 8. To calculate the fenestration standard design VT in Column H. Multiply Column H by 1.2. 9. Coefficients for; U-factor (CSu,i), SHGC (Cs,,i), and VT(Csi,i, can be found in Table NA5-2, through Table NA5-5 of the Reference Nonresidential Appendices NAS. The Coefficient for SHGC and VT are only entered for the fenestration products. Enter "0" when not applicable. 10. Calculate the TDV Standard Design for each Envelope Assembly Type: TDVstd = Column C x [Column E x ({U-factorsi x Csui) + (SHGCsi x Cssi) + (VTa x Csti))] for each Assembly Type. See Nonresidential Manual Examples in Section 3.7.1 for details. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 10 of 47 OVERALL ENVELOPE TDV ENERGY APPROACH (Page 4 of 6) ENV-3C Project Name CalAmp VR Suite 100 Date 3/4/2014 TDV for the Proposed Design Building, See Reference Nonresidential Appendix NA5.3 Occupancy Type and Coefficients Tables IZ Nonresidential, See Table NA5-3 • 24-Hour Use, NA5-4 See Table • Retail, See Table NA5-5 Climate Zone: A B c D E F G H 1 J K L M N Assembly Type' Orientation^ Number Of Like Assembly Type" Total Exterior Surface Area' Fenestration Type" Criteria Coefficients for Proposed TDV Energy" Assembly Type' Orientation^ Number Of Like Assembly Type" Total Exterior Surface Area' Fenestration Type" Criteria U-factor° RSHGC' Vf Cool Roof* Overhang'" Proposed TDV Energy" Assembly Type' Orientation^ Number Of Like Assembly Type" Total Exterior Surface Area' Fenestration Type" U-factor' SHGC^ VT' Gsu,i Css.l Ct,i McR MoH Proposed TDV Energy" Wall N 540 0.226 11.97 1,463 Window N 1 240 Site-built 0.710 0.286 0.500 4.97 151.32 0.67 f.OOO 11,328 Wall N 1 762 0.226 11.97 439 Window N 1 78 Site-built 0.710 0.286 0.500 4.97 151.32 0.67 1.000 3,682 Wall E 1 696 0.226 11.97 1,885 Window E 1 336 Site-built 0.710 0.286 0.500 1.81 279.82 5.40 1.000 28,266 Wall E 1 t50 0.226 11.97 406 Window E 1 48 Site-built 0.710 0.286 0.500 1.81 279.82 5.40 1.000 4,038 Wall N 1 288 0.226 11.97 780 Window N 1 48 Site-built 0.710 0.286 0.500 4.97 151.32 0.67 1.000 2,266 Wall W 1 384 0.226 11.97 1,040 Window W 1 144 Site-built 0.710 0.286 0.500 2.92 348.89 1.89 1.000 14,823 Wall W 1 462 0.226 11.97 1,251 Window W 1 240 Site-built 0.710 0.286 0.500 2.92 348.89 1.89 1.000 24,706 Wall W 1 680 0.226 11.97 1,842 Window W 1 40 Site-built 0.710 0.286 0.500 2.92 348.89 1.89 1.000 4,118 Total Proposed Design" t02,333 Proposed < Standard YES 1. Indicate type of assembly for the Envelope (e.g. Wall, Floor, Roof, Window, Skylight & Door). One assembly type for each row. 2. Indicate the orientation for walls, doors & windows. 2A. Note: Grouping of like assemblies in the same orientation is allowed. Enter the number in column C. 3. Indicate the Exterior Surface Area of the Assembly for that one assembly or If like assemblies then the total surface area of all assemblies in the same orientation. 4. Enter the type of fenestration; M = Manufactured, SB = Site-built, SK = Skylight and F = Fabricated. 5. Proposed Design U-factor are from Table 143-A, B or C for ttie appropriate assembly type. 6. Proposed Design SHGC are from Table 143-A, B or C. Enter "0" if not applicable. Note: Not all vertical windows have an overhang then assume SHGC as value entered. 7. To calculate the fenestration proposed design VT in Column H. Multiply Column G by 1.2. 8. Coefficients for; U-factor (CSu,i), SHGC (Cs,,i), and VT(Cst,i, can be found in Table NA5.2, through Table NA5.5 of the Reference Nonresidential Appendices NAS. The Coefficient for SHGC and VT are only entered for the fenestration products. Enter "0" when not applicable. 9. Calculate the Cool Roof, MCR, first by using the next page (Page S of 6). Enter the value in the Proposed Column L. 10. Calculate the Overhang MOH on the next page (Page S of 6). Enter the value In the Proposed Column M. 11. The Proposed TDV energy use for all assemblies other than roofs must be equal to or less than Standard TDV in Page 3 of 6. Therfore; TDVp = Column D x [(U factor x CSu) + (CRui x URI x MCRI) + (SHGCP X CSsi x MOH ) + (VTP x CSt)] Enter the calculated value in Column N. 12. Sum up all the Proposed TDV Energy in Column N and enter value in the cell. Similarly enter the sum of all Standard TDV Energy and compare. Proposed must be s to the Standard. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID^^ Page 11 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: B Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School BIdg. 12 Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component Overall Envelope TDV Energy • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: Odeg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Meets Criteria or Requirements Equipment^ Inspection Criteria Pass Fail - Descrit>e Reason^ Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1A • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity^ 21,798 Btu/hr • • Minimum Heating Efficiency^ 8.00 HSPF • • Max Allowed Cooling Capacity^ 47,533 Btu/hr • • Cooling Efficiency^ 13.0 SEER/11.0 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment^ Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Pass Fail - Describe Reason^ Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1B • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity^ 36,951 Btu/hr • • Minimum Heating Efficiency^ 7.70 HSPF • • Max Allowed Cooling Capacity^ 81,803 Btu/hr • • Cooling Efficiency^ 13.0 SEER/10.9 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked. 3. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 12 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: IZl Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School BIdg. Bl Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component • Overall Envelope TDV Energy • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Meets Criteria or Requirements Equipment^ Inspection Criteria Pass Fail - Describe Reason^ Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1C • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 18,554 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 23,445 Btu/hr • • Cooling Efficiency' 13.0 SEER/11.0 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • FIELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Pass Fail - Describe Reason^ Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1D • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 10,504 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 89,649 Btu/hr • • Cooling Efficiency' 13.0 SEER/10.9 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked. 3. Indicate Equipment Type: Gas (Pkg or. Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 13 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: • Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School BIdg. 121 Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component _ Overall Envelope Energy TDV • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: Odeg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Meets Criteria or Requirements Equipment^ Inspection Criteria Pass Fail - Describe Reason' Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1E • • Equipment Type^: Split DX • • Number of Systems 2 • • Max Allowed Heating Capacity' 20,173 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 161,417 Btu/hr • • Cooling Efficiency' 13.0 SEER/10.9 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment' Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Pass Fail - Descrit)e Reason' Item or System Tags (i.e. AC-1, RTU-1, HP-1) IF • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 21,729 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 80,182 Btu/hr • • Cooling Efficiency' 13.0 SEER/10.9 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked. 3. Indicate Equipment Type: Gas (Pkg or. Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 14 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Parti of5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: El Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School BIdg. 13 Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component Overall Envelope Energy TDV • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: Odeg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Meets Criteria or Requirements Equipment' Inspection Criteria Pass Fail - Describe Reason' Item or System Tags (i.e. AC-1, RTU-1, HP-1) IG • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 11,997 Btu/hr • • Minimum Heating Efficiency' 8.00 HSPF • • Max Allowed Cooling Capacity' 65,202 Btu/hr • • Cooling Efficiency' 13.0 SEER/11.0 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment' Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Pass Fail - Descrit)e Reason' Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1H • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 16,481 Btu/hr • • Minimum Heating Efficiency' 8.00 HSPF • • Max Allowed Cooling Capacity' 46,692 Btu/hr • • Cooling Efficiency' 13.0 SEER/11.0 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked. 3. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 15 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Project Address 2177 Salk Ave Carlsbad Climate Zone Total Cond. Floor Area 11,262 Addition Floor Area n/a GENERAL INFORMATION Building Type: • Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School BIdg. • Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction: • New Construction • Addition • Alteration Approach of Compliance: • Component „ Overall Envelope Energy TDV • Unconditioned (file affidavit) Front Orientation: N, E, S, W or in Degrees: Odeg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Meets Criteria or Requirements Equipment' Inspection Criteria Pass Fail - Describe Reason' Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1J • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 9,104 Btu/hr • • Minimum Heating Efficiency' 8.00 HSPF • • Max Allowed Cooling Capacity' 47,930 Btu/hr • • Cooling Efficiency' 13.0 SEER/11.0 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment' Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Pass Fail - Describe Reason' Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1K • • Equipment Type^: Split DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 10,107 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 77,181 Btu/hr • • Cooling Efficiency' 13.0 SEER/10.9 EER • • Duct Location/ R-Value Conditioned / 4.2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked. 3. Indicate Equipment Type: Gas (Pkg or. Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 16 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 2 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Discrepancies: EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 17 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 3 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the applicable boxes by all acceptance tests that apply and listed all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems. The NA number designates the Section in the Appendix of the Nonresidential Reference Appendices Manual that describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Systems Acceptance: Before occupancy permit is granted for a newly consfructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. Systems Acceptance: Before occupancy permit is granted. All newly installed HVAC equipment must be tested using the Acceptance Requirements. The MECH-1 C form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. The equipment requiring testing, person performing the test (Example: HVAC installer, TAB contractor, controls contractor, PE in charge of project) and what Acceptance test must be conducted. The following checked-off forms are required for ALL newly installed equipment. In addition a Certificate of Acceptance forms shall be submitted to the building department that certifies plans, specifications, installation, certificates, and operating and maintenance information meet the requirements of §10-103(b) and Title-24 Part 6. The building inspector must receive the properly filled out and signed forms before the building can receive final occupancy. TEST DESCRIPTION MECH-2A MECH-3A MECH-4A MECH-SA MECH-SA MECH-7A MECH-8A MECH-9A MECH-1 OA MECH-11A Equipment Requiring Testing or Verification Qty. Outdoor Ventilation For VAV & CAV Constant Volume & Single-Zone Unitary Air Distribution Ducts Economizer Controls Demand Control Ventilation DCV Supply Fan VAV Valve Leakage Test Supply Water Temp. Reset Hydronic System Variable Flow Control Automatic Demand Shed Control Carrier 25HBC3-36 w/FV4B003 3 • • • • • • • • • • Carrier 25HBC3-60 w/FV4B006 6 • m • • • • • • • • Canier 25HBC3-18 W/FV4B002 1 • • • • • • • • • Canrier 25HBC3-48 W/FV4B006 1 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Paae 18 of 47 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 4 of 5) MECH-1 C Project Name Date CalAmp VR Suite 100 3/4/2014 TEST DESCRIPTION MECH-12A MECH-13A MECH-14A MECH-1 SA Equipment Requiring Testing Qty. Fault Detection & Diagnostics for DX Units Automatic Fault Detection & Diagnostics for Air & Zone Distributed Energy Storage DXAC Systems Thermal Energy Storage (TES) Systems Test Performed By: Can-ier 25HBC3-36 w/FV4B003 3 • • • • Canrier 25HBC3-60 w/FV4B006 6 • • • • Can-ier 25HBC3-18 w/FV4B002 1 • • • • Can-ier 25HBC3-48 w/FV4B006 1 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 19 of 47 CERTIFICATE OF COMPLIANCE (Part 5 of 5) MECH-1 C Project Name CalAmp VR Suite 100 Date 3/4/2014 Documentation Author's Declaration Statement I certify that this Certificate of Compliance documentation is accurate and complete. Name Tom Harinton Signature / Company HARINTON MECHANICAL DESIGN INC Date 3/4/2014 Address 27475 Ynez Rd #246 CEA# CEPE# City/State/Zip jemecula, CA 92591 Phone 858-435-4803 The Principal l\/lechanical Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the mechanical design. • This Certificate of Compliance identifies the mechanical features and performance specifications required for compliance with Title-24, Parts 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name Victor Newman ^'9"^*"^" Company Date 3-4-14 Address 21 Windsor St License* 23110 City/State/Zip Harvard, MD 01830 Phone Mandatory Measures Indicate location on building plans of Note Block for Mandatory Measures. MECHANICAL COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the 2008 Nonresidential Manual. Note: The Enforcement Agency may require all forms to be incorporated onto the building plans. Bl MECH-1 C Certificate of Compliance. Required on plans for all submittals. Bl MECH-2C Mechanical Equipment Summary is required for all submittals. El MECH-3C Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation. Bl MECH-4C Fan Power Consumption is required for all prescriptive submittals. EnergyPro 5.1 by EnergySoft User Number 4945 RunCode: 2014-03-04711:56:54 ID: Page 20 of 47 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date CalAmp VR Suite 100 3/4/2014 Item or System Tags (i.e. AC-1, RTU-1, HP-1) Indicate Air Systems Type (Central, Single Zone, Package, VAV, or etc..) Item or System Tags (i.e. AC-1, RTU-1, HP-1) IA 1B 1C Number of Systems 1 1 1 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value T-24 Sections MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 8.00 HSPF 7.70 HSPF 7.70 HSPF MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 13.0 SEER/11.0 EER 13.0 SEER/10.9 EER 13.0 SEER/11.0 EER MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(b), 112(c) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(c), 11 S(a) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) 92 cfm 162 cfm 192 cfm MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(C) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(C) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Programmable Switch Programmable Switch Programmable Switch MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Setback Reguired Setbacl< Reguired Setback Reguired MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(f) Auto Auto Auto MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(g) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 123 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 124 Conditioned / 4.2 Conditioned / 4.2 Conditioned / 4.2 PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 21,798 Btu/hr 36,951 Btu/hr 18,554 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 26,010 Btu/hr 43,987 Btu/hr 13,464 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 33,273 Btu/hr 57,262 Btu/hr 16,411 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 32,479 Btu/hr 56,023 Btu/hr 15,357 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Constant Volume Constant Volume Constant Volume Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Yes Yes Yes Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(d) No No No Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(e) No Economizer No Economizer No Economizer Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(p) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(1) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(k) No No No 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(g) apply. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page21of47 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date CalAmp VR Suite 100 3/4/2014 Item or System Tags (i.e. AC-1, RTU-1, HP-1) Indicate Air Systems Type (Central, Single Zone, Packag e, VAV, or etc..) Item or System Tags (i.e. AC-1, RTU-1, HP-1) 1D IE 1F Number of Systems 1 2 1 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value T-24 Sections MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 13.0 SEER/10.9 EER 13.0 SEER/10.9 EER 13.0 SEER/10.9 EER MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(b), 112(c) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(c), 115(a) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) 255 cfm 270 cfm 134 cfm MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Programmable Switch Programmable Switch Programmable Switch MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Setback Reguired Setback Required Setback Required MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(f) Auto Auto Auto MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(q) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 123 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 124 Conditioned / 4.2 Conditioned / 4.2 Conditioned / 4.2 PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 10,504 Btu/hr 20,173 Btu/hr 21,729 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 43,987 Btu/hr 87,974 Btu/hr 43.987 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 62,755 Btu/hr 112,992 Btu/hr 56,127 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 53,740 Btu/hr 109,860 Btu/hr 54,922 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Constant Volume Constant Volume Constant Volume Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(C) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(C) Yes Yes Yes Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(d) No No No Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(e) No Economizer No Economizer No Economizer Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(g) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(i) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(k) No No No 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(g) apply. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page22of47 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date CalAmp VR Suite 100 3/4/2014 Item or System Tags (I.e. AC-1, RTU-1, HP-1) Indicate Air Systems Type (Central, Single Zone, Package, VAV, or etc..) Item or System Tags (I.e. AC-1, RTU-1, HP-1) 1G IH 1J Number of Systems 1 1 1 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value T-24 Sections MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 8.00 HSPF 8.00 HSPF 8.00 HSPF MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 13.0 SEER/11.0 EER 13.0 SEER/11.0 EER 13.0 SEER/11.0 EER MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(b), 112(c) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(c), 11S(a) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) 282 cfm 112 cfm 209 cfm MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Programmable Switch Prijgrammable Switch Programmable Switch MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Setback Required Setback Reguired Setback Reguired MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(f) Auto Auto Auto MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(g) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 123 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 124 Conditioned / 4.2 Conditioned / 4.2 Conditioned / 4.2 PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 11,997 Btu/hr 16,481 Btu/hr 9.104 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 35,189 Btu/hr 26.010 Btu/hr 26.010 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a& b) 45,641 Btu/hr 32.684 Btu/hr 33.551 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144{a& b) 42,814 Btu/hr 32.390 Btu/hr 32.910 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Constant Volume Constant Volume Constant Volume Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Yes Yes Yes Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(d) No No No Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(e) No Economizer No Economizer No Economizer Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(Q) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(1) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(k) No No No 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(g) apply. EnergyPro 5.1 by EnergySofl User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 23 of 47 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date CalAmp VR Suite 100 3/4/2014 Item or System Tags (i.e. AC-1, RTU-1, HP-1) Indicate Air Systems Type (Central, Single Zone, Packag e, VAV, or etc..) Item or System Tags (i.e. AC-1, RTU-1, HP-1) IK Number of Systems 1 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value Indicate Paj je Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value T-24 Sections MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 7.70 HSPF MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 13.0 SEER/10.9 EER MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(b), 112(C) Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(c), 115(a) n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) 248 cfm MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Programmable Switch MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Setback Required MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(f) Auto MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(g) n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 123 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 124 Conditioned/4.2 PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 10.107 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 43.987 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 54.027 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(a&b) 53.769 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Constant Volume Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(C) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(c) Yes Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(d) No Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(e) No Economizer Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(f) Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(q) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(1) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electric Resistance Heating' Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted 144(k) No 1. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to § 144(g) apply. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page24of47 MECHANICAL VENTILATION AND REHEAT MECH-3C Project Name CalAmp VR Suite 100 Date 3/4/2014 MECHANICAL VENTILATION (§121(b)2) REHEAT LIMITATION (§144(d)) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H 1 J K L M N Zone/System Condition Area (ft') CFM per ft' Min CFM By Area BXC Number Of People CFM per Person Min CFM by Occupant EXF REO'D V.A. Max of DorG Design Ventilation Air CFM 50% Of Design Zone Supply CFM BX0.4 CFM/ft' Max. of Columns H, J, K, 300 CFM Design Minimum Air Setpoint Transfer Air 1A 610 0.15 92 6.1 15.0 92 92 92 IA Total 92 92 IB 1.080 0.15 162 10.8 15.0 162 ^62 162 IB Total 162 162 IC 307 0.50 154 7.7 25.0 192 192 192 IC Total 192 192 1D 1.687 0.15 253 17.0 15.0 255 255 255 ID Total 255 255 1E 1,185 0.15 178 18.0 15.0 270 270 270 IE Total 270 270 1F 725 0.15 109 9.0 15.0 134 134 134 IF Total 134 134 IG 1.880 0.15 282 18.8 15.0 282 282 282 IG Total 282 282 IH 745 0.15 112 7.5 15.0 112 112 112 Totals Column 1 Total Design Ventilation Air C Minimum ventilation rate per Section §121, Table 121-A. E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. H Required Ventilation Air (REQ'D V.A.) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column D or G). 1 Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. J Design fan supply CFM (Fan CFM) x 50%; or the design zone outdoor airflow rate per §121. K Condition area (ft^) x 0.4 CFM / ft^; or L Maximum of Columns H, J, K, or 300 CFM M This must be less than or equal to Column L and greater than or equal to the sum of Columns H plus N. N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (Column H) and the Design Minimum Air (Column M), Column H minus M. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 25 of 47 MECHANICAL VENTILATION AND REHEAT MECH-3C Project Name CalAmp VR Suite 100 Date 3/4/2074 MECHANICAL VENTILATION (§121(b)2) REHEAT LIMITATION (§144(d)) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B c D E F G H 1 J K L M N Zone/System Condition Area (ft') CFM per ft' Min CFM By Area BXC Number Of People CFM per Person Min CFM by Occupant EXF REQ'D V.A. Max of DorG Design Ventilation Air CFM 50% of Design Zone Supply CFM BX0.4 CfM/if Max. of Columns H, J, K, 300 CFM Design Minimum Air Setpoint Transfer Air 1H Total 112 112 1J r,390 0.15 209 13.9 15.0 209 209 209 IJ Total 209 209 1K 1,653 0.15 248 16.5 15.0 248 248 248 IK Total 248 248 Totals Column 1 Total Design Ventilation Air C Minimum ventilation rate per Section §121, Table 121-A. E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. H Required Ventilation Air (REQ'D V.A.) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column D or G). 1 Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. J Design fan supply CFM (Fan CFM) x 50%; or the design zone outdoor airflow rate per §121. K Condition area (ft') x 0.4 CFM / ft'; or L Maximum of Columns H, J, K, or 300 CFM M This must be less than or equal to Column L and qreater than or equal to the sum of Columns H plus N. N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (Column H) and the Design Minimum Air (Column M), Column H minus M. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page26of47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp tor Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts BXEX746/ (CXD) 1A - Supply Fan 0.500 76.0% 97.0% 1.0 506 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 506 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 1.200 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa - 1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Une 6)' 0.422 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 27 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) 1B - Supply Fan 0.750 77.0% 97.0% 1.0 749 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 749 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 2,000 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -{ SPa -1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0.375 W/CFM TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPns 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 28 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) IC - Supply Fan 0.500 76.0% 97.0% 1.0 506 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 506 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 600 A) If filter pressure drop (SP,) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SP,) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SP,) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -(SP, -1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0.843 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 29 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) ID - Supply Fan 0.750 77.0% 97.0% 1.0 749 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 749 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 2.000 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1-( SPa-1)/SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Une 6)' 0.375 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 30 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) IE - Supply Fan 0.750 77.0% 97.0% 2.0 1.498 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 1.498 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 4.000 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa - 1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Line 6)' 0.375 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 31 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) IF - Supply Fan 0.750 77.0% 97.0 % 1.0 749 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 749 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 2,000 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa - 1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Une 6)' 0.375 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014^3-04711:56:54 ID: Page 32 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) 1G-Supply Fan 0.750 77.0% 97.0% 1.0 749 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 749 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 1.600 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -(SPa -1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Une 6)' 0.468 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 33 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) 1H- Supply Fan 0.500 76.0% 97.0% 1.0 506 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 506 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 1.200 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa- 1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Une 6)' 0.422 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 34 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c). B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) IJ - Supply Fan 0.500 76.0 % 97.0 % 1.0 506 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 506 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 1.200 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa - 1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Une 6)' 0.422 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 35 of 47 FAN POWER CONSUMPTION MECH-4C Project Name CalAmp VR Suite 100 Date 3/4/2014 NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) A B c D E F Fan Description Design Brake HP Efficiency Number of Fans Peak Watts B X E X 746 / (CXD) Fan Description Design Brake HP Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) IK - Supply Fan 0.750 77.0% 97.0% 1.0 749 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 749 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards. 2) SUPPLY DESIGN AIRFLOW (CFM) 2,000 A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W. C. or 245 Pascal then enter SPa on line 4. Enter Total Fan pressure drop across the fan (SP,) on Line 5. 5) SP, B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1-( SPa-1)/SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Une 3 x Une 6)' 0.375 W/CFM 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1.25 W/CFM for VAV systems. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 36 of 47 MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM Project Name CalAmp VR Suite 100 Date 3/4/20^4 Equipment and System Efficiencies §111: Any appliance for whioh there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. §115(a): Fan type central furnaces shall not have a pilot light. §123: Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124: Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603,604, and 605 of the CMC Standards. Controls §122(e): Each space conditioning system shall be installed with one of the following: IA. Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or 1B. An occupancy sensor to control the operating period of the system; or IC. A 4-hour timer that can be manually operated to control the operating period of the system. 2. Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. §122(g): Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. §122(0): Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §122(b): Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone §122(a&b): Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. Ventilation §121(e): Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f): All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. §121 (f): Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance Service Water Heating Systems §113(0) Installation 3. Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110° F. 2. Circulating service water-heating systems shall have a control capable of automatically turning off the circulating pump when hot water is not required. EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 37 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name 1A Floor Area 610 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 34,000 Total Room Loads 985 22,880 1,220 638 12,241 Total Output (Btuh) 34,000 Return Vented Lighting 0 Output (Btuh/sqft) 55.7 Return Air Ducts 1,144 612 Cooling System Return Fan 0 0 Output per System 34,000 Ventilation 92 603 1,758 92 3,505 Total Output (Btuh) 34,000 Supply Fan 1,727 -1,727 Total Output (Tons) 2.8 Supply Air Ducts 1,144 612 Total Output (Btuh/sqft) 55.7 Total Output (sqft/Ton) 215.3 TOTAL SYSTEM LOAD 27,499 2,978 15,244 Air System CFIUI per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 Carrier 25HBC3-36 wl FV4B003 32,479 0 26,010 Airflow (cfm/sqft) 1.97 Airflow (cfm/Ton) 423.5 Outside Air (%) 7.6 % Total Adjusted System Output 32,479 0 26,010 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jun 5 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F 67 °F 87 "F 88 "F Outside Air 92 cfm 70 °F <— Heating Coil Supply Fan 1,200 cfm 1 88 "F ROOM 70 °F COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 81 / 67 "F Outside Air 92 cfm 75 / 59 °F < « 1 Cooling Coil Supply Fan 1,200 cfm 52 / 50 °F 39.8 % ROOM 74/59°F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 38 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IB Floor Area 1,080 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 57,500 Total Room Loads 1,645 40,306 2,160 1,053 20,173 Total Output (Btuh) 57,500 Return Vented Lighting 0 Output (Btuh/sqft) 53.2 Return Air Ducts 2,015 1,009 Cooling System Return Fan 0 0 Output per System 58,000 Ventilation 162 431 3,359 162 6,207 Total Output (Btuh) 58,000 Supply Fan 2,557 -2,557 Total Output (Tons) 4.8 Supply Air Ducts 2,015 1,009 Total Output (Btuh/sqft) 53.7 Total Output (sqft/Ton) 223.4 TOTAL SYSTEM LOAD 47,324 5,519 25,840 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Carrier 25HBC3-60 w/FV4B006 56,023 0 43,987 Airflow (cfm/sqft) 1.85 Airflow (cfm/Ton) 413.8 Outside Air (%) 8.1 % Total Adjusted System Output 56,023 0 43,987 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 10 AM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 "F 67 °F 87 "F 88 "F Outside Air 162 cfm 70 "F <— Heating Coil Supply Fan 2,000 cfm 1 88 °F ROOM 70 "F COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 77 / 66 "F Outside Air 162 cfm 75 / 59 "F < =• i Cooling Coil Supply Fan 2,000 cfm 51 / 49 "F 38.2 % ROOM 74 / 58 "F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 39 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IC Floor Area 307 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 17,600 Total Room Loads 502 9,201 1,190 147 6,692 Total Output (Btuh) 17,600 Return Vented Lighting 0 Output (Btuh/sqft) 57.3 Return Air Ducts 460 335 Cooling System Return Fan 0 0 Output per System 17,400 Ventilation 192 1,715 2,497 192 7,341 Total Output (Btuh) 17,400 Supply Fan 1,727 -1,727 Total Output (Tons) 1.5 Supply Air Ducts 460 335 Total Output (Btuh/sqft) 56.7 Total Output (sqft/Ton) 211.7 TOTAL SYSTEM LOAD 13,563 3,687 12,975 Air System CFM per System 600 HVAC EQUIPMENT SELECTION Airflow (cfm) 600 Can-ier 25HBC3-18 wl FV4B002 15,357 1,997 13,464 Airflow (cfm/sqft) 1.95 Airflow (cfm/Ton) 413.8 Outside Air (%) 32.0 % Total Adjusted System Output 15,357 1,997 13,464 Outside Air (cfm/sqft) 0.63 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F Outside Air 192 cfm 69 "F 58 "F 110 °F • 113 "F —• Heating Coil Supply Fan 600 cfm 1 112 "F ROOM 70°F COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83/68°F Outside Air 192 cfm 75 / 61 op < « 77 / 63 "F 54 / 52 °F • ^ 56 / 53 "F • Cooling Coil Supply Fan 600 cfm 57 / 54 °F 46.9 % ROOM 74/61 "F EnergyPro 5.1 by EnergySoft User Number 4945 RunCode: 2014-03-04711:56:54 ID: Page 40 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name ID Floor Area 1,687 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 57,500 Total Room Loads 1,916 42,822 3,401 0 0 Total Output (Btuh) 57,500 Return Vented Lighting 0 Output (Btuh/sqft) 34.1 Return Air Ducts 2,141 0 Cooling System Return Fan 0 0 Output per System 58,000 Ventilation 255 2,202 4,385 255 9,902 Total Output (Btuh) 58,000 Supply Fan 2,557 -2,557 Total Output (Tons) 4.8 Supply Air Ducts 2,141 0 Total Output (Btuh/sqft) 34.4 Total Output (sqft/Ton) 349.0 TOTAL SYSTEM LOAD 51,863 7,786 7,345 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Can-ier 25HBC3-60 w/FV4B006 53,740 2,035 43,987 Airflow (cfm/sqft) 1.19 Airflow (cfm/Ton) 413.8 Outside Air (%) 12.8% Total Adjusted System Output 53,740 2,035 43,987 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design condifions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F 65 "F 86 °F 87 "F Outside Air 255 cfm 70 °F •4 Heating Coil Supply Fan 2,000 cfm 1 87 "F ROQM^ 70 °F _| COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83 / 68 "F Outside Air 255 cfm 75 / 60 "F •* 76 / 61 °F 51 / 50 "F • El 52 / 50 °F • Cooling Coil Supply Fan 2,000 cfm 1 53 / 51 °F 42.1 % ROOM J 74 / 59 "F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 41 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IE Floor Area 1,185 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 57,500 Total Room Loads 3,305 78,366 3,602 389 7,965 Total Output (Btuh) 115,000 Return Vented Lighting 0 Output (Btuh/sqft) 97.0 Return Air Ducts 3,918 398 Cooling System Return Fan 0 0 Output per System 58,000 Ventilation 270 2,066 5,348 270 10,459 Total Output (Btuh) 116,000 Supply Fan 5,113 -5,113 Total Output (Tons) 9.7 Supply Air Ducts 3,918 398 Total Output (Btuh/sqft) 97.9 Total Output (sqft/Ton) 122.6 TOTAL SYSTEM LOAD 93,382 8,949 14,107 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 4,000 Carrier 25HBC3-60 w/FV4B006 109,860 0 87,974 Airflow (cfm/sqft) 3.38 Airflow (cfm/Ton) 413.8 Outside Air (%) 6.8 % Total Adjusted System Output 109,860 0 87,974 Outside Air (cfm/sqft) 0.23 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 5 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F Outside Air 270 cfm 70 °F < 67 °F 88 °F • 89 "F —• Heating Coil Supply Fan 4,000 cfm 1 ROOM 89 "F 70 °F _J COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 82 / 67 "F Outside Air 270 cfm 75 / 59 "F -4 « Cooling Coil Supply Fan 4,000 cfm 52 / 49 "F 39.1 % ROOM 74 / 59 »F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 42 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IF Floor Area 725 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 57,500 Total Room Loads 1,640 38,911 1,790 569 11,435 Total Output (Btuh) 57,500 Return Vented Lighting 0 Output (Btuh/sqft) 79.3 Return Air Ducts 1,946 572 Cooling System Return Fan 0 0 Output per System 58,000 Ventilation 134 1,028 2,660 134 5,173 Total Output (Btuh) 58,000 Supply Fan 2,557 -2,557 Total Output (Tons) 4.8 Supply Air Ducts 1,946 572 Total Output (Btuh/sqft) 80.0 Total Output (sqft/Ton) 150.0 TOTAL SYSTEM LOAD 46,386 4,450 15,195 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Can-ier 25HBC3-60 w/FV4B006 54,922 0 43,987 Airflow (cfm/sqft) 2.76 Airflow (cfm/Ton) 413.8 Outside Air (%) 6.7 % Total Adjusted System Output 54,922 0 43,987 Outside Air (cfm/sqft) 0.19 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 5 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 "F Outside Air 134 cfm 70 "F •4 67 °F 88 "F • 89 "F —• Heating Coil Supply Fan 2,000 cfm 1 89 "F ROOM 70 °F COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 82 / 67 "F 75 / 59 "F 50 / 48 °F Outside Air 134 cfm 75 / 59 "F •4 =• 51 / 49 °F • Cooling Coil Supply Fan 2,000 cfm 1 39.1 % 52/49^ ROOM 74/59<'F I EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 43 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IG Floor Area 1,880 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 46,000 Total Room Loads 1,366 29,717 3,760 0 0 Total Output (Btuh) 46,000 Return Vented Lighting 0 Output (Btuh/sqft) 24.5 Return Air Ducts 1,486 0 Cooling System Return Fan 0 0 Output per System 47,000 Ventilation 282 2,475 4,479 282 10,946 Total Output (Btuh) 47,000 Supply Fan 2,557 -2,557 Total Output (Tons) 3.9 Supply Air Ducts 1,486 0 Total Output (Btuh/sqft) 25.0 Total Output (sqft/Ton) 480.0 TOTAL SYSTEM LOAD 37,720 8,239 8,390 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,600 Can-ier 25HBC3-48 w/ FV4B006 42,814 2,874 35,189 Airflow (cfm/sqft) 0.85 Airflow (cfm/Ton) 408.5 Outside Air (%) 17.6% Total Adjusted System Output 42,814 2,874 35,189 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 "F 64 "F 84 °F 86 "F Outside Air 282 cfm 70 "F < Heating Coil Supply Fan 1,600 cfm 1 86 "F ROOM J 70 "F _J COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83 / 68 °F 76 / 61 °F 51 / 50 °F Outside Air 282 cfm 75 / 60 "F -4 >• 53 / 51 °F • Cooling Coil Supply Fan 1,600 dm 1 54 / 51 "F 43.6 % ROOM 74 / 60 °F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 44 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IH Floor Area 745 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 34,000 Total Room Loads 965 22,127 1,490 432 8,138 Total Output (Btuh) 34,000 Return Vented Lighting 0 Output (Btuh/sqft) 45.6 Return Air Ducts 1,106 407 Cooling System Return Fan 0 0 Output per System 34,000 Ventilation 112 945 2,065 112 4,300 Total Output (Btuh) 34,000 Supply Fan 1,727 -1,727 Total Output (Tons) 2.8 Supply Air Ducts 1,106 407 Total Output (Btuh/sqft) 45.6 Total Output (sqft/Ton) 262.9 TOTAL SYSTEM LOAD 27,012 3,555 11,525 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 Can-ier 25HBC3-36 w/ FV4B003 32,390 0 26,010 Airflow (cfm/sqft) 1.61 Airflow (cfm/Ton) 423.5 Outside Air (%) 9.3 % Total Adjusted System Output 32,390 0 26,010 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 4 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F 66 "F 86 °F 88 »F Outside Air 112 cfm 70 °F •4 Heating Coll Supply Fan 1,200 cfm 1 87 "f ROOM 70 °F _J COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83 / 68 "F •-^ Outside Air ^ 112 cfm 75 / 59 °F •4 « 76 / 60 °F 51 / 49 "F —• 52 / 50 "F • Cooling Coil Supply Fan 1,200 cfm 53 / 50 °F 40.6 % ROOM J 74 / 59 °F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 45 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IJ Floor Area 1,390 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 34,000 Total Room Loads 971 21,972 2,780 0 0 Total Output (Btuh) 34,000 Return Vented Lighting 0 Output (Btuh/sqft) 24.5 Return Air Ducts 1,099 0 Cooling System Return Fan 0 0 Output per System 34,000 Ventilation 209 1,832 3,512 209 8,093 Total Output (Btuh) 34,000 Supply Fan 1,727 -1,727 Total Output (Tons) 2.8 Supply Air Ducts 1,099 0 Total Output (Btuh/sqft) 24.5 Total Output (sqft/Ton) 490.6 TOTAL SYSTEM LOAD 27,728 6,292 6,366 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 Canrier 25HBC3-36 w/ FV4B003 32,910 0 26,010 Airflow (cfm/sqft) 0.86 Airflow (cfm/Ton) 423.5 Outside Air (%) 17.4% Total Adjusted System Output 32,910 0 26,010 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F Outside Air 209 cfm 70 "F 64 "F • 84 "F 85 °f —• Heating Coil Supply Fan 1,200 cfm ROOM 1 85 °F I 70 °F _J COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83 / 68 "F Outside Air ^ 209 cfm 75 / 60 "F •4 76 / 61 °F 51 / 50 °F • El 52 / 50 °F • Cooling Coil Supply Fan 1,200 cfm 1 53 / 50 "f 42.5 % ROOM 74 / 60 °F _J EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 46 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name CalAmp VR Suite 100 Date 3/4/2014 System Name IK Floor Area 1,653 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 57,500 Total Room Loads 1,598 36,284 3,306 0 0 Total Output (Btuh) 57,500 Return Vented Lighting 0 Output (Btuh/sqft) 34.8 Return Air Ducts 1,814 0 Cooling System Return Fan 0 0 Output per System 58,000 Ventilation 248 2,181 4,333 248 9,625 Total Output (Btuh) 58,000 Supply Fan 2,557 -2,557 Total Output (Tons) 4.8 Supply Air Ducts 1,814 0 Total Output (Btuh/sqft) 35.1 Total Output (sqft/Ton) 342.0 TOTAL SYSTEM LOAD 44,650 7,639 7,068 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 Can-ier 25HBC3-60 w/FV4B006 53,769 1,873 43,987 Airflow (cfm/sqft) 1.21 Airflow (cfm/Ton) 413.8 Outside Air (%) 12.4 % Total Adjusted System Output 53,769 1,873 43,987 Outside Air (cfm/sqft) 0.15 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jul 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 34 °F 66 °F 86 "F 87 »F Outside Air 248 cfm 70 "F Heating Coil Supply Fan 2,000 cfm 87 "F ROOM 70 °F COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83 / 68 "F Outside Air _j 248 cfm 75 / 60 °F •4 « 76 / 61 °F 51 / 50 °F • El 52 / 50 °F • lr Cooling Coil Supply Fan 2,000 cfm 53 / 50 "F 41.8% ROOM 74 / 59 "F EnergyPro 5.1 by EnergySoft User Number: 4945 RunCode: 2014-03-04711:56:54 ID: Page 47 of 47 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 FIELD EVALUATION REPORT Subject: Temperature Chamber Inspection Site: CalAmp 4520 Executive Drive, Plaza 1 San Diego, CA 92121 USA Installation Site: CalAmp 2231 Rutherford Road Carlsbad, CA 92008 USA Applicant: CalAmp 4520 Executive Drive, Plaza 1 San Diego, CA 92121 USA Main Contact: Phone: Email: Terence Walker (alt. Vivian Thudium) (760) 268-4327 twalker@calamp.com Issued by: Nemko USA Inc. 11696 Sorrento Valley Road, Suite F San Diego, CA 92121 USA Report: 171672 Page 1 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, California, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 EQUIPMENT COVERED: DESCRIPTION iManufacturer: Thermotron Industries IVIodel: S-8 Rated: 230V 3-phase, 60Hz, 19A Dimensions: 70 1/4 x 32 x 39 1/2 inches (HWD) Serial No.: 12368RF Description: Equipment under review was a Thermal Cabinet. The construction consisted of a non-detachable power cord with a twist-locl< plug, Primary wiring, Primary and Secondary circuits, switches, motors and a light. Report: 171672 Page 2 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Sorrento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 PHOTOS OF EQUIPMENT: SERIAL NO. MAX. LOAOl AMPS L^RGisT NIQTQRBBB HP •BH AMPS miW lQ^QS•Q| ANIP. RECOMMENDED SERVICE mi SH\PPtQ' STANDBY LIMITSI TMl=l>M OPERATORS MANUAL 1 RliM INDUSTRIES ^^^HP^HKOm,t HOLLAND Ml U S A 49423 Equipment marking Report: 171672 Page 3 of 13 29 March 2011 @ Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 PHOTOS OF EQUIPMENT: Report: 171672 Page 4 of 13 29 March 2011 ® Nemko Nemko USA, Inc. 11696 Sorrento Valley Road San Diego, California, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 Report: 171672 Page 5 of 13 29 March 2011 ® Nemko Nemko USA, Inc. 11696 Sorrento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 Report: 171672 Page 6 of 13 29 March 2011 ® Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 Report: 171672 Page 7 of 13 29 March 2011 ® Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, California, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 Report: 171672 Page 8 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 PURPOSE OF EVALUATION: Articles 90-6 and 110-3 of the National Electrical Code (NFPA 70) establish that the Authority Having Jurisdiction over an electrical equipment installation may rely on independent testing laboratories that are qualified and equipped to perform safety evaluations. Typically, equipment installed in the U.S. has been investigated. Listed, and labeled by a Nationally Recognized Testing Laboratory (NRTL). In the absence of such approval(s), judgment as to the suitability and compliance of equipment can be a burden to the Authority Having Jurisdiction. As such, a qualified laboratory may be acquired to evaluate such equipment for purposes of assessing compliance with applicable standards and requirements. APPLICABLE STANDARDS: The equipment covered was evaluated for compliance with applicable requirements of the National Electrical Code, NFPA-70, 2002 edition and the essential requirements from UL 61010-1. Engineering judgment was applied where the standard in use did not address the conditions and circumstances of a particular facet of the installation. METHODOLOGY OF EVALUATION: All equipment evaluated was visually inspected for future reference. Following test, inspection, and corrective actions taken, (where deemed necessary), a serialized field label was affixed adjacent to the ballast near the cord connection. ENGINEERING CONSIDERATIONS: The following considerations apply: 1. Grounding Continuitv - All accessible dead metal parts that could become energized were tested for continuity. The bonding conductors in the construction were inspected and found to be of adequate size and secured properly. Test Equip. Settings Location Result / Verdict 1 N012 40A@2min. Cord plug prong to metal door window frame 1.1V (25.7mQ) PASS 2 N012 40A(g2min Cord plug prong to metal door latch (top portion) 0.9V (22.5ma) PASS 3 N012 40A(g2min Cord plug prong to metal panel hinge (bottom portion) 0.7V (17.5mQ) PASS 4 N012 40A(g2min Cord plug prong to metal front screen panel screw (bottom portion) 1.0V (25.0mQ) PASS 2. Dielectric Strength - De-eneraized orimarv circuits were tested for dielectric strength at 2121VDC between primary and protective earth with no breakdown or excess leakage current. All units tested. Test Equip. Settings Location Result / Verdict 1 N096 2130VDC Primary to Ground at the cord plug prong with Light and Power switches in the ON position, and the C and MH contactors pushed in. No breakdown, PASS Report: 171672 Page 9 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 NON-COMPLIANCE ISSUES: The following issues required corrective action prior to issuance of the serialized Nemko USA Inc. label to the equipment. 1. Cord strain relief mount to enclosure was loose. 2. Unit marked 3-phase, no single phase rating. 3. Phase jumpers much smaller size (16-18AWG?) than power cord and mains wiring (10-14AWG). 4. Bare (uninsulated) unused conductor near mains termination. 5. (minor) Loose screws placed near thermocouple terminals. CORRECTIVE ACTION PERFORMED: 1. Tightened with pliers. 2. Confirmation of single phase wiring configuration (see attached email). 3. Replaced with new 12AWG jumpers (see attached email). 4. Used electrical insulation tape on exposed conductor wires. 5. Tightened/replaced screw terminals for the Watlow device/display controller. Report: 171672 Page 10 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 CONSTRUCTION DETAILS General- In addition to the specific construction details investigated at the installation site, the following general requirements apply at all times: 1. Spacings- In primary circuits, minimum 1/4 inch is maintained through air and over surfaces of insulating material, between current-carrying parts of opposite polarity, and between current-carrying parts and dead metal parts (unless integral to NRTL-approved component). 2. Mechanical Assembly- Components such as connectors, wiring terminals, and lamps are reliably mounted and prevented from shifting. 3. Internal wiring- Internal wiring connections terminate in approved wire nuts. All primary wiring is rated minimum 600V, 105°C minimum (UL style 1015 or equivalent). 4. Corrosion Protection - All ferrous metal parts are suitably protected against corrosion by painting, plating, or the equivalent. 5. Grounding - All exposed dead metal parts and all dead metal parts within the enclosure that are exposed to contact during servicing, and that are likely to become energized in a fault condition, are reliably connected to the grounding system terminating at the grounding terminal or lead of the supply wire connection. 6. Current-carrving parts - All current-carrying parts are copper or copper-based alloy. 7. Accessibilitv of live parts - All uninsulated live parts in primary circuitry are housed within suitable enclosure materials and are adequately guarded against contact by the articulated finger probe. All conductive parts that could become energized with hazardous voltage were tested for continuity with the protective earthing terminal or conductor at the supply input. 8. Approved Components - For purposes ofthe evaluation, unless otherwise noted, critical components requiring certification or evaluation by a Nationally Recognized Testing Laboratory include the following: Report: 171672 Page 11 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 Thermal Cabinet Component Manufacturer Model Ratings Approvals Plug Hubbell Twist-lock, NEMA L5-30P 3C, 250V, 30A UL, CSA Cord Carol SOOW 10AWG/4C, 600V UL, CSA Terminal block Unable to verify Designated: TB1 Unable to verify Unable to verify Primary wire Carol 1230, 1335, 1032, 1015, 10269A 14-12AWG, 600V, VW-1, 105''C UL, CSA Fuse holders (3 provided) Unable to verify Designated: F2-F4 Unable to verify Unable to verify Fuses (6 provided) Fusetron FRN-R-12, D-Class 250V, 12A, Time Delay, Current Limit UL, CSA Contactors (2 provided) Furnas 42BE25AFL1, Series A, Designated: C, MH 240V, 3HP UL, CSA Step-down Transformer Impervitran Industries Control B500BTZ13 Primary: 230V, Secondary: 115V, 0.5KVA UL, CSA Fuse Fusetron FNM 5, Designated: Fl 250V, 5A UL, CSA Solid State Relay Gordos Arkansas GA5-4D25, Designated: SSR 250V, 25A UL, CSA Power / Light Switches (2 provided) Carling 9614 125V, 15A/250V, 10A Unable to verify Main PCB Unable to verify Marked: 28/48 Main 5F82737, 882321 Designated: 2800 MAIN BD Unable to verify Unable to verify CRE PCB Solid State Relays Unable to verify Opto 22 Designated: CRE BD MP120D4 Designated: K1-K3 Unable to verify DC Unable to verify UL, CSA Controller / Meter (not connected to AC, only TC) Watlow 94AA-1DAQ-00RG 100-240V, 50/60HZ, 12VA None Buzzer (not connected) Sonalert SC110 120V, 21mA UL Condensing unit Copeland FBAH-0100-CAV-003 Marked: 22KB4 208/230V, 60Hz, 10.3A UL, CSA Compressor (Low Stage) Copeland RRL4-0100-CAV Marked: B/M2B N9- 415 208/230V CSA Circulation motor Magnetek JB1S082N Marked: 785695 115/230V, 50/60HZ, 2.3A, Class B Unable to verify Light receptacle Unable to verify Unable to verify Unable to verify Unable to verify Light bulb Unable to verify Unable to verify 120V, 40W Unable to verify Report: 171672 Page 12 of 13 29 March 2011 (N) Nemko Nemko USA, Inc. 11696 Son-ento Valley Road San Diego, Califomia, 92121, USA Phone (858) 755-5525 Fax (858) 259-7170 CONCLUSION: The equipment covered by this report was evaluated and tested to comply with Nationally Recognized Standards. Following evaluation, test, and corrective action where deemed necessary, the units were labeled with a serialized Nemko USA Field Evaluation Label, as specified below: Equipment Manufacturer Equipment (Serial No.) Label serial numbers Thermotron 12368RF 520 The Nemko USA Field Label indicates that evaluation was performed with the intent of meeting appropriate Nationally Recognized Standards, and suggests that the equipment is suitable for acceptance by the Authority Having Jurisdiction in accordance with Article 110-3 ofthe National Electrical Code (NFPA 70). inspected By: Thomas Landrey Safety Engineering Supervisor Report: 171672 Page 13 of 13 29 March 2011 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE _L Business Name ^ 1 , Calflmp Business Contact Telephone # (^rfeUfiici ^S|ate Zip Code APN# „ 24-2.-. oa-03 Mailing Address . Sojme. as cUboVc City state Zip Code Plan Flle# Telephone # -5ZZZ.X30U1 The following questions represent the facility's activities, NOT the speciflc project description. PARTI : FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item. whether your business will use, process, or store any of the following hazardous materials. If any of the itenris are circled. jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 3. Flammal>le/Combustlble Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12. Radioactives applicant must contact the Fire Protection Agency with Occupancy Rating: _ 13. Corrosives 14. Other Health Hazards 15. None of These. PART M: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH questions is yes, applicant must contact the County of San Diego Hazardous Materials Call (858) 505-6700 prior to the issuance of a building pemiit. FEES ARE REQUIRED YES HAZARDOUS MATERIALS DMSIONS (HM^: If th ; Division, 5500 Overiand Ave., Suite 110, San Diego, Project Completion Date: / / Expected Date of Occupancy: / / (for new construction or remodeling projects) Is your business listed on the reverse side of this forni? (checl( all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Will your business use an existing or Install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 galk>ns? (Califomia's Aboveground Petroleum Storage Act). the answer to any of the CA 92123. • CalARP Exempt I Date Initials • CalARP Required L Date Initials • CalARP Complete Date Initials PART III; SAN DIEGO Dis • •- .--T—r T.-L^j--. answer to any of the questkjns below Is yes, applicant must contact the Air Pollutton Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: If the answer to questions 4 or 5 Is yes, applicant must also submit an asbestos notification fonn to the APCD at least 10 working days prior to commencing demolition or renovatton, except demolition or renovation of residential structures of four units or less. Contact the APCD for more Information. YES NO 1. • 2. • 3. 4. 5. • • • Will the subject fecility or construction activities Include operattons or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdaDcd.ora/info/facts/Dermits.Ddf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questtons). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1.000 feet of the outer boundary of a school (K through 12)7 (Search the Califbmia School Directory at http://wvw.cde.ca.aov/re/sd/ fbr public and private schools or contact the appn>priate school district). Has a survey been perfbrmed to determine the presence of Asbestos Containing Materials? Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Will there t>e demolition involving the removal of a load supporting structural memt>er? Briefly describe business activities: torporatr off(ce Briefly descrit>e proposed project: I decl9[e under penalty of perjury that to the best of my knowledge and belief lecjavB under penalty of | Name of Owner or Authorized Agent isppnses made herein are taie and correct. Signature ef Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASED FOR BUILDING PERMTT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division ^ PLUMBING, Development Services <^ ^ ELECTRICAL, Building Diviston ^ CITY OF MECHANICAL I635 FaradayAvenue CARLSBAD ^^'^^Ig^^^ wwwcansbadcagov Project Address:' ' Permit Noj Information provided below refen to wori« being done on the above mentioned permit only. This form must be compteted und returned to the Building Division before the permit cnn be issued. Building Dept Fax: (760) 602-B558 Number of new or relocated f ixturei, traps, or floor drains — Q New building sewer line? Ves No X. Number of new roof drains? 0 Instail/aher water line?..— Number of new water healers? Number of new, relocated or replaced gas outlets? Q Number of new hose bibs? « 0 Retideniioi Pennits: New/expanded service: Number of new amps: Minor Remodel onfy: Ves No Commercial/industrial: Tenant Improvement: Number of existing amps Irwoh/edbi this proiect: Number of new amps Involved in this project- O New Construction: Amps per Panel: Single Phase , Number of new amperes Three Phase „ Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? 0 New or relocated duct worb? Ves X No Number of new fireplaces? 0 Number of new exhaust fans? ^ Relocate/install vent? ^ Number of new exhaust hoods?. Number of new boilers or compressors? Number of HP Uf-^ B-18 Page 1 of 1 Rev. 03/09 ^ PLUMBING, Development Services <^ C ELECTRICAL, Building Division ^ C , y y OF MECHANICAL 1635 Faraday Avenue WORKSHEET 76O602-2719 B-18 CARLSBAD - — www cansbadca gov Project Address: /-Ml _)UIK Permit No.: Information provided below refers to worb being done on the obove mentioned permit only. This form must be completed and returned to the Building Division before the permit cnn be issued. Building Dept. Fox: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains \..(^9.f^.§..k^..^ ^ ^ ^ New building sewer line? Ves ^ No Number of new roof drains? o Install/alter water line? .LnCU?..yi^.l»;fe:Nr Ijng, Number of new water hBtiters7...L^.Q.Q:*:{}£..Z.22.y^l±..I.D Number of new, relocated or replaced gas outlets? 0 Number of new hose bibs? ^ Residential Permits: New/expanded service: Number of new amps: Minor Remodel onfy: Wei No Commerdai/lnduttricd: Tenant Improvement: Number of existing amps Involved in thb project: Q Number of new amps involved In thb prol&t: HOT) New Construction: Amps per Paneb Single Phase Number of new amperes Three Phase Numlier of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps?.. New or relocated duct worb? Ves X No Number of new fireplaces? Q Number of new exhaust fans? 0 Relocate/install vent? 0 Number of new exhaust hoods? G Number of new boilers or compresson? Number of HP B-18 Page 1 of 1 Reu. 03/09 INDUSTRIAL WASTEWATER DISCHARGE PERMIT , , SCREENING SURVEY DateC:)3jOg-/l4 Business Name CCk\ m p Street Address 2111 ^(k\K fiVt. Email Address Krg-tfr if c^e.<tr^rrcsffp^A.rr^ PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Assembly Automotive Repair Battery Manufacturing Biofuei iVIanufacturing Biotech Laboratory Bull< Chemical Storage Car Wash Chemical Manufacturing Chemical Purification Dry Cleaning Electrical Component Manufacturing Fertilizer Manufacturing Film/X-ray Processing Food Processing Glass Manufacturing Industrial Laundry lnl< Manufacturing Laboratory Machining / Milling Manufacturing Membrane Manufacturing (i.e. water filter membranes) Metal Casting / Forming Metal Fabrication Metal Finishing Electroplating Etectroless plating Anodizing Coating (i.e. phosphating) Chemical Etching / Milling Printed Circuit Board Manufacturing Metal Powders Forming Nutritional Supplement/ Vitamin Manufacturing Painting / Finishing Paint Manufacturing Personal Care Products Manufacturing Pesticide Manufacturing / Packaging Phamnaceutical Manufacturing (including precursors) Porcelain Enameling Power Generation Print Shop Research and Development Rubber Manufacturing Semiconductor Manufacturing Soap/Detergent Manufacturing Waste Treatment/Storage SIC Code(s) (If known): Brief description of business activities (Production / Manufacturing Operations):, Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal / day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact Signature, Title Phone No. ENCINA WASTEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760)438-3941 FAX: (760)476-9852 PC140006 2177 SALKAV HAI AMP Tl - 99 501 .SF TOTAI // CB140541 2177 SALKAV 100 CALAMP -11.428 SHELL TO OFF CB140S42 2177 SALKAV 200 no t:^^?!, PUWJ, e&iL.^ 4 O^PID ^iT^f^^-i (^-"^ Final Inspection required by: • Plan • CM&I SW •ISSUED, J acv. Approved Ar Date, By BUILDING lolrU-'^'r^t^^ PLANNING CIS ENGINEERING , 3/T^T/I^ FIRE Expedite? N ^I(H1(^ DIGrrAL FILES Required? Y N J Hazlvlat APCD Health Forms/Fees sent _ .Rec'd Due? By Encina f N Fire V N HazHealthAPCD Y N PE&M^«<..SK. Y N School Y N Sewer Y N Stormwater Y N SpeciaJJnspection Y N CFD/Y) N PFF: (V) N STg OKIU^ Comments Date Date Date Date Building Planning Engineering Fire Need? jrflpone • Done 04-29-2014 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Pernnit No:PCR14066 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC #: Project Title: Applicant: KIM RATTE 2177 SALKAV CBAD PCR 2120210300 Lot#: 0 $0.00 Construction Type: NEW PC140006 CALAMP-REVISE EXISTING SHOWER ROOIVIS @ 1ST FLOOR TO BE ADA COIVIPLIANT-TO BE Status Applied Entered By: Plan Approved Issued Inspect Area ISSUED 04/14/2014 RMA 04/29/2014 04/29/2014 4944 COLLINGWOOD DR SN DIEGO CA 92109 858 794-3222 XT306 Owner: VENTANA REAL LLC 1525 FARADAY AVE #100 CARLSBAD CA 92008 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees $107.50 $0.00 $0.00 Total Fees: $107.50 Total Paynnents To Date: $107.50 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth In Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which YOU have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv otherwise expired. CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carisbadca.gov Plan Check Revision No. (^C^i^P^^ nrlgin.l Plan Check Na.it l^^OOOW Project Address 2ll7 SalK f\^t So'&C IQO^ZOO Date OlMjR Contact Email Kraf-irg ol g s I ^ n CO rpsd Com Contact Address CbllfnguDc^c/i^r. ntyS^ Diego zip I^W General Scope of Workl^tvlSg ShoVOtT rOOmS on l^'^'f f. jO CQfVip(y uJ/ Cpdc Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 • Elements revised: Plans • Calculations • Soils • Energy • Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets l^vi'sc -ev.\S"HA^ 5b^ut)fir nsoms on f ir<;f Tl-1 neu) Shed "Flotjr 'h> loc -ADA complfant. 5 • Does this revision, in any way, alter the exterior of the project? • Yes 6. Does this revision add ANY new floor area(s)? • Yes ^ No 7. Does this revision affect any fire related issues? • Yes ^ No 8. Is this a complete set? • Yes ^ No ^Signature. No 1635 Faraday Avenue, Carlsbad, CA 92008 Eb" 760-602-2719 Fax: 760-602-8558 Email: building@carl5badca.gov vvww.carlsbadca.gov EsGil Corporation In (Partnersfiip witli government for (BuiCcfing Safety DATE: 4/24/14 • APPLICANT • JURIS. JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECKNO.; PC14-0006 PCR14-066 SET; I PROJECT ADDRESS: 2177 Salk Ave Suite 100 & 200 PROJECT NAME: Calamp Shower Revision - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. I I The applicant's copy of the check list has been sent to: IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person ^ REMARKS: Applicant to add notes in red to City sets. By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • MB • PC 4/17/14 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad PC14-0006 PCR14-066 4/24/14 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC14-0006 PCR14-066 PREPARED BY: Doug Moody DATE: 4/24/14 BUILDING ADDRESS: 2177 Salk Ave Suite 100 & 200 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA (Sq.Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdction Code Cb By Ordinance BIdg. Permt Fee by Ordranoe Plan Check Fee by Ordinance • Type of Review: • Complete Review $107.50 • Structural Only •R epetltive Fee ^ Repeats Based on hourly rate • Other g Hourly EsGil Fee 1 $86.00 Hr.@ $86.00 Comnnents: Sheet 1 of 1 macvalue.doc +