HomeMy WebLinkAbout2180 RUTHERFORD RD; ; CB011597; PermitV ,oC--t --
City of Carlsbad . . ' 05/22/2001
1635 Faraday Av Carlsbad, CA 92008
Electrical Permit Permit No:CB011597
Building Inspection Request Line (760) 602-2725
Job Address;
Permit Type:
2180 RUTHERFORD RD CBAD
Parcel No:
Reference#:
ELEC
2120702500 Lot#: 0
Status:
Applied:
Entered By;
Plan Approved:
. Issued:
ISSUED
04/30/2001
RMA
05/22/2001
05/22/2001
Project Title: CALLAWAY-EMERGENCY GENERATOR Inspect Area:
ELECT TRANSFER SWITCH ONLY-GOLF BALL BLDG
Applicant:
BERG ELECTRIC
650 OPPER ST
ESCONDIDO CA 92029
760-746-1003
Total Fees: $337.00
Electric Issue Fee
Single Phase per AMP
Three Phase per AMP
Three Phase 480 Per AMP
Remodel/Alteration per AMP
Remodel Fee .
Temporary Service Fee
TestMeter Fee
Other Electrical Fees
Additional Fees
TOTAL PERMIT F(:ES
--, 7/j )
lnspectoi::., //
Owner:
CALLAWAY GOLF CO
C/0 DONALO H DYE
22135 RUT-HERFORD RD
CARLSBAD CA 920013
Total Payments To-Diite: $0.00
0
0
0
,0
. ' •.','
0050 05/22/01 0002 01 02
CGP 337,00
Balance Due: $337.00
$10.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$327.00
$0.00
$337.00
FINAL APPROVAL
Date: ~11/fal Clearance: ____ _
NOTICE: Please take NOTICE lhatapproval of your project includes lhe 'imposition' of fees, dedications, reservations, or other exactions hereafter collectively
r'eferied to as ~ees/exactions." You have 90 days from the data lhls permit was issued to protest imposition of these fees/exactions. If you protest lhem, you must
follow the protest procedures set forth In Government Code Secllon 66020(a), and file the protest and any olher required Information with the City Manager for
PfOCO!Slng In acoordance with Ca~sbad Munlclpal Code Secllon 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, orannul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specHled fees/exactions DOES NOT APPLY to water and sewer connection fees and cepaclly
changes, nor planning, zoning, grading.or other slnilar application processing or service lees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which vou have ·-·louslv been alven a NOTICE slmllarto this or as to which Iha statute ofllmltations has oreviouslv otherwise exnired.
Legal Description Lot No. Subdivision Name/Number
Assessor's Parcel II Existing Use
(E.M \.\?4.fr<l'c.~.
SQ.FT, I/of Stories
Name ~tlll>V H fNN-tc_ Address . . City State/Zip Telephone # .
~l!iiiili'IBIM}li-!"&~:,"i-':,"'~".~]"~J.fil§i:.~•z.s.,·~::'!_;;;~~n&~~~:;·$:'f..~<'.~~~f~~1t~~~~~~~b\~4.£,;i·h;'.t:~1~~s:~~~'r·~:;..'.i~}~
C-tfy,tn.,&{ 6-ze,P: C-Q Zo!SI rt<UM,'( C,/KlSIMI:? C4\ 7z:oc.8 c,,o) 9;so-S~>1
Name · Addren City $.tate/Zfp Telephone #
~IiP~~fllrd\~·S%·-.1~:,•;j,m;X-i::i.-.::-;.:..~h-iZ,.,ft:;\J~.:i.;;~·;..~2:.fil.~/!J::~~;~'!~;~~~:lf.f~~U~fi.~':f,~
(Sec, 7031.5 Business aild Profassions Code: ·Any City or County which requiris a permit to construct, alter, improve, demolish or repair any structure, prior to Its
issuance, also requires the eppllcant for such permit to file a signed stetem~nt that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 .of Division 3 of the· BuslnesJ and ProfeSsloflS CodeJ-c;,r that he Is exempt therefrom, and the basis for the alleged
exempilon. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)), 25Ex.b E"t.t.C..T'l',IC.. C,4?:> .oee-1'=-'.$(r; ~-1>,po
Nam·• · Address City State/Zip JO Telephone#
State Llcenae 11 --'-c.1,1"'-af!c..<Cl,.~.l,!P. --:c-~-:;;cc=---:::cc-_ City Business License , ttL9/, be)
f!/J,~~~iw..!:~'8;._-~"'~~LC&1:1.2:l!.L~~~~t.a~-__.iCA~_.[!.~,1~2~'-=-,-.,S~.:.=":~c:.=~78Q
Oes!gner Name Address City State/Zip Telephone
State L:lcensli # .;:;;;;;;;;;;;;;;;;;::;:;;;;;;;;:;==:::: ,-=~==
~:~~~--.tt;J.d.:.;2·;:i.·i.:,•,-. · p;;'\i.!.~:.,d::1~·~I::::.:~...:~~:-. ..(?;,J;J,t~~~~'1r~~~:;~}!lf~~:$~~~G~t~~.;.-,..:~. ·:;.~:..-:fif!J:~· -_{r1
Workers' Compensation Declaration: I-herel;,y affirm under penalty of perjury one of the·folfo~lng declarations:
0 I have and will maintain a certificate of consent to seJf.fnsure fOr workers' compensation as provided by Section 3700 of the Labor Code, for the perf9rmance
of the work for which this permit is issued.
0 I have and will fflaintaln workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
Issued, My worker's compensa,tion Insurance carrier and policy number are:
Insurance Company____________________ Polley No.____________ Expiration Date _______ _
ITHIS SECTION NEED NOT BE COMPLETE!;> IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
D CERTIFICATE OF EXEMPTION: I certify·that In the performance of the work for which this perniit is issued, I shall not employ any person In any manner so as
to become subject to the Workers' Compensation Laws of California,
· WARNING: FaJIUf'e to ••cure worbra' comptnHtlon covlflU■ la unlawful, and sheU aubject· an employer to crlmlnal panaltiu and clvll fines up to one hundred tholf■and doUer■-($190,000), in addition to the co1t of compensation, damages u provided for-In Sectl"on 3706 of the Labor code, fnterest and attorn!ly's fees.
SIGNATURE, ________________________ ~---DATE ________ _
~~J~Jfai:---~'\·\?~·--w~£};~t.1,1.1,:::~~i:i1·.t;.t~~fili.~f .. r~~-tl,'.j,,_-:~~ifili~:,;1: .. :, ·~'"~7·,\'B!.. ~~:-:~~~~':\};~·,:·.,1r.~l::..rr_F. .. ~~::1··.; I hei'Elby affirm that I am exempt from the Contractor'i Llce";;se Law for tf1e followi;;g .. rees;~:'.... · · .. --~ .................. , ..... · · · "'· \: '"'· .;.} ....... ·-
□ I, es owner of the propert'( or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec, 7044, Business and Profaas~ons Code: The Contractor'i Uc&mae Law does.not apply to an owner of property who builds or Improves thereon, and who does
such work himself or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the,bulldlng or Improvement is
sold within on, year of completion, the own,r•builder will hive the·burdari of proving t}lat he dld not build or·lmprove for the purpose of sale).
0 -1, as owner of the property, am exclusively contracting with llcense·d contractors to construct the project (Sec, 7044, Business and Professions Coda: The
Contractor's Llcensa Law does not apply ta an owner of property who builds or Improves thereon, and contracts for such projects with cantractor(s) licensed
. pursuant to 'the contractor's Uc8nse Law).
EJ I am exempt under Section ______ Business and Professions Code fer this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement, 0 YES □No
2. I (have/ have not). signed an application-for a building permit for-the proposed work,
3. I have contracted _with the foUowlng per8on Cfirrril to provide the proposed cqnst;1,1ctlon (include nam9 /address/ phone number/ contractors license number):
4. I plan to prqvide portions of the work, but I have hired the foflowlng ·person to ~oordinate, supervise and provide the major work (include name / address / phone
number/ contractqrs license number).:_---------------------------------------------
6, I will provide some of the work, but I have contracted (hired) th8 following persons to provide ttie work Indicated Unclude name/ address / phone number/ type
cf work):. _______ ~------------------------------~------------
PROPERTY OWNER SIGNATURE DATE ________ _
.. ~~~~w~:.~~~~~~*;t;~t2~e;~;_;:::;c~~~§
is the applicant or future building occupant required to subffllt a business plan, acutely hazardous materials registration form or risk management and prevention
progra~ under·Sections 25505, 26533 or 25634 of the Presley•Tanner·Hazardoljs Substance Account Act? 0 YES O NO
Is the applicant or future building occupant required to obtain.a permit from the air pcllutlcin control district or air quality management district? O YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a sch9ol·sJte_? D YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DJSTRICT.
~~•i:iiiriiihimwWWWii'»fF;::!(},',;@j.*;.:!.,;-t~¾:~.tt,'k;;-$.:1.S:!':T·ti~,-½<,'.,~t:t~~~~T-..:V~~•S!!.St;T-,SP"'-'!W'l-fa.;~t~."!'<'.,1.:;1~t:-~: ~t~ i)'!-~'Z' ~-·'l::t·:;·~~~~-: ig~..J!.~~5!f!!:~.1!12.',,1\S·~~ .... ,, • ..,...._. ____ ..,......,,... __ -..., •'• -~ X't,;..,,....,o;c.,,-.. ____ ;;')i!". __.... .u--, ,...,-,,l~. •· ..... :u.;...,.. ••• ,_."-_ .. , •.• ,, '• .,, -, .• ,J•,.-_ • .,._,.,.
I hereby affirm that there Is a construction lending agency for the performance of the work for whlch.~his permit Is issued {Sec. 3097(1) Civil Code), ·
LENDER'S NAME
'.
' .
City of Carlsbad Bldg Inspection Request
For: 05/31/2001
Permit# CB011597 Inspector Assignment: TP ---
Title: CALLAWAY-EMERGENCY GENERA TOR
Description: ELECT TRANSFER SWITCH ONLY-GOLF BALL BLDG
Type:ELEC Sub Type:
Phone: 6195716754
Job Address: 2180 RUTHERFORD RD
Suite: Lot
Location:
APPLICANT BERG ELECTRIC
Owner: CALLAWAY GOLF CO
Remarks:
Total Time:
CD Description
39 Final Electrical
Associated PCRs
Inspection History
Date Description
05/29/2001 34 Rough Electric
0
Act Comments
Inspector:.,£?
Requested By: SAM
Entered By: ROBIN
£ ____________ _
Act lnsp Comments
NR TP NO SUPP. ON SITE
DATE: 05/11/01
JURISDICTION: CARLSBAD
PLAN CHECK NO.: 01-1597
EsGil Corporation
1n !Pamursliip witli (jo11trn11Unt for '.BuiUing Safety
SET:11 ...
PROJECT ADDRESS: 2180 RUTHERFORD ROAD
PROJECT NAME: CALLAWAY TRANSFJ!:R SWITCH ADD.
□ APPLICANT
□ JURIS.
□ PLAN REVIEWER
□ FILE
IZ! The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D · The plans transmitted her.ewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
arcid should be corrected ahd resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
· Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant's copy of the check list has been sent to:
· 0 Esgil Cor.poration staff did not advise the applicant that the plan check has been completed.
IZ! Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax#:
Mail Telephone Fax In· Person
IZ! REMARKS: APPLICANT WALKED IN THE REVISED PLAN.
By: Morteza Beheshti
Esgil Corporation
0 GA O MB O EJ O PC
Enclosures:
05/11 ' .'/
trnsmU.dot
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 05/09/01
JURISDICTION: CARLSBAD
PLAN CHECK NO.: 01-1597
EsGil Corporation
2n Partnersliip witli (jovtrn1Mnt for 'lJuilaing Safety
SET:I
PROJECT ADDRESS: 2180 Rt1THERFORD ROAD
PROJECT NAME: CALLAWAY TRANSFER SWITCH ADD.
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck. /
IZJ The check list tram1mitted herewith is for your information. The plans are being held a/2sgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the Jurisdiction to forward to the applicant
contact person.
IZJ The applicant's copy of the check list has been sent to:
Greg Treso
650 OPPER STREET ESCONDIDO, CA., 92029
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
IZJ Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Cl€-C. ( \/-1-1) Telephone#: (760746-1003
Datecontacted:.5l~/0 1 (by:~) Fax #:(760)746-1317
Mail L:Ferephone ✓ Fax v In Person
0 REMARKS:
By: Morteza Beheshti
Esgil Corporation
0 GA O MB O EJ O PC
Enclosures:
4/~0 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
' , CARLSBAD 01-1597
05/09/01
GENERAL PLAN CORRECTION LIST
JURISDICTION: CARLSBAD PLAN CHECK NO.: 01-1597
PROJECT ADDRESS: 2180 RUTHERFORD ROAD
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 4/30
REVIEWED BY: Morteza Beheshti
FOREWORD (PLEASE. READ):
DATE REVIEW COMPLETED:
05/09/01
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
• Please make all corrections on the original tracings and submit two new complete sets of
prints to: ESGIL CORPORATION.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
4 CARLSBAD 01-1597
05/09/01
♦ ELECTRICAL PLAN REVIEW
♦ 1996 NEC
1. The single line indicates the transformers and generators are part of future work.
However; they are all marked as new. Also, further clarify the feeders to the
transformers as new or future work not under this permit.
2. Show the ampere interrupting capacity (AIC) ratings of the new load break switch. NEC
110-9, 230-65.
3. Rebar or ground rods are not acceptable grounding electrodes for commercial
applications in the City of Carlsbad. Please describe what the "UFER" ground will be.
(footage, conductor material and size, depth in footing.)
Note: The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform
the plan review for your project. If you have any questions regarding these plan review
items, please contact Morteza Beheshti at Esgil Corporation. Thank you.
' CARLSBAD 01-1597
05/09/01
VALUATION AND PLAN CHECK FEE
JURISD1cr10N: CARLSBAD
PREPARED BY: Morteza Beheshti
PLAN CHECK NO.: 01-1597
DATE: 05/09/01
BUILDING ADDRESS: 2180 RUTHERFORD ROAD
BUILDING OCCUPANCY: NA TYPE OF CONSTRUCTION: NA
BUILDING AREA · Valuation Reg. VALUE
PORTION ( Sq. Ft.) Multiplier Mod.
Air C9nclitioning
Fire Sorinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
1994 UBC Building Permit Fee I.;, I
.1994 UBC Build.Ing Perm.It Fee . I • f
Type of Review: D Complete Review D Structural Only
D Other D Repetltlve Fee =8 Repeats 0 Hourly 31 Hours *
l!sgll Plan Review Fee
* Based on hourly rate
C
Comments: ELECTRICAL PLAN REVIEW ONLY.
($)
$326.81 I
$261.451
Sheet of
macvaiue.doc