HomeMy WebLinkAbout2180 RUTHERFORD RD; ; CB050939; Permit/ ~ ?~~ ~~Y~! ~!~!!.~~!ooe
04-27-2oosd Commercial/Industrial Permit Permit No: CB050939
Building Inspection Request Line (760) 602-2725
Job Address: 2180 RUTHERFORD RD CBAD
Permit Type: Tl Sub Type: INDUST
0
NEW
Parcel No: 2120702500 Lot #: Status:
Valuation: $123,814.00 Construction Type: Applied:
Occupanc,y Group: Reference #: Entered By:
Project Title: CALLAWAY GOLF Plan Approved:
3,994 SF OFFICE TO OFFICE, BRAND MANAGEMENT Issued:
Applicant:
SMITH CONSUL TING ARCHITECTS
STE 200
12220 EL CAMINO REAL
SAN DIEGO CA 92121
(858) 793-4777
Building Permit· .
Add'I Building Perrnit Fee
Plan Check
Add'I Plan Check fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con; Fee
$620.48
$0.00
$403.31
$0.00
$0.00
$26.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Inspect Area:
Plan Check#:
Owner:
CALLAWAY GOLF CO
C/O DONALD H DYE
2285 RUTHERFORD RD
CARLSBADCA 92008
Meter Size
Add'I Red. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF
PFF (CFO Fund)
License Tax
License Tax.(CFD Fund)
Traffic Impact Fee
Traffic Impact (CFO Fund)
PLUMBING TOTAL
Et.ECTRICAL TOT AL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Add(tipn~J Fees·
fbTAL PERMIT FEES
Total Fees: $1,183.79 Total Payments To Date: $395.31 Balance Due:
ISSUED
03/22/2005
MOP
04/27/2005
04/27/2005
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$110.00
$24.00
$0.00
$0.00
$0.00
$0.00
$1,183.79
$788.48
3 l)JJ;D ING PLANS 6955 04/27/05 0002 01 02
.P: IN S'ff>RRGE 6c..c&+"'-~
--ATTACHED
I ~ nspector:. -
FINAL APPROVAL
Date: ~/23/4;r--' I
CGP 788#48
Clearance: _____ _
NOTICE: Please take NOTICE that approval of your pf9iect includes the "Imposition• of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.• You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your-right to protest.the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f i n f whi h I N · h ·limi i n h r vi I h i
'I
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92.008
Lot No. Subdivision Name/Number
·FOR OFFICE USE ONLY
PLAN CHECK NO. Cl5 • Gf.l3
EST. VAL. '1 ~ 8~
Plan Ck. Deposit >L· ;}\
Validated By ~ _
Date 3{1-~ 1
Total # of units
(Sec. 7031 .5 Business a,nd Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and· Professions Code) or that he is exempt therefrom, and the basis for the alleged
e~emption. AnyA v!ola~ot Section 7031.5 by any a plicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). / /.
-.J 1,t., • L JY\ i TC---~C { ~ 3-<.. 0 u.s V ~S. q;;20 r I 5 9 F' .--. CO 1--r
Name
State License# ~3~7_._J.,_5--c...5_~( __ Address 'T) City State/Zip Telephone#
City Business License # / / 9 £ 5 f3.3 License Class ____ J::)_._.-<., ___ _
St~e/Zip Te',:,h~e J
----'--~. .· ~-:{!l?JO -c~i!.~ 77ql:f!J2 , .~---"' , :-: ,,,,.~,, ~ '\, ,' ,,, •; ~ . :':::''Y -~i.:E ·M.; , ';,,, •,, ~.' ~ .,.' ~ , V ~ .. ' ' ", ,~,,;_<· .?~~ , ,(,, !
o kers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
. issued. My worker's compensation insurance carrier and policy number are: 1.. ".2. "'::l. 3 /,J S U / /
Insurance Company Vtlo D r-:sd aJ ,e I n 6 ux::a .... k) ~Policy No. _,) :.) 'J 7 'D. I Expiration Date '()_I I DS
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS) / /
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
0 0001, i • • the cost of compensation, damages as provided for in Section 3706 of th1; f;llbor code, interest and attorney's fees.
SIGNATUib,,.~h , DATE '-f -~ 7 ~ t:J..S .
i.;·>o;wr.iif +a· .m ERDEbLARAiioN~, ',:,~·· ' .. ,, "·. ·--.-... , ... , ,. 2 .. :. ~--:___ · .. :·. 'c:"::,;:-7_:f!';,,v:j::·y._·:., __ ,_ "-· ... · .. , ... ,.,_, .. ~,0,.~~--
1 hereby af r hat I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he. did not build or improve for the purpose of sale).
0 I, as owner of the property, am !a)Xclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Lawi. ·
D I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted.with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number/ contractors-license number): ______________ ~----~~-----~-------------------
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated !include name / address / phone number / type
of work): __________________ ~~----------'-----------------------------
PROPERTY OWNERSIGNATURE __________________ ~---DATE ________ _
ibOMPLETR"THISSECTJON.FORNO«i,RES/Dffe71ALJ3UltDINGP1:RMlifS1/0NLY -,; < ~ < "'f::-::il:1 ;".;,',, /L. _.,:~£'. ;:7~·,:/'" 7 ,,.·· >
Is the applicant or future building occupant required to subnijt a business plan, acutely hazardous materials registration form or risk management and prevention
·program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollutiQn control district or air quality management district? 0 YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES D NO
· 1F ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
f~1~:~&~~~QitQ.~:t~NPJr:l~1?l'~ycy-_::_~;~~=~~ ,-,~ ,;,, ,·-: --~
I hereby affirm that there is a-construction.lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS:;;;;:;:::;:===::::::::;:;::;:::;;;~;;::;;;::::::::;;;;::::;::;::;:;:;;;;:;:;;:;;:;;;::;;;::::::;::::::;:;:;;;::-:;;::;:;-;;;:;;;;;;::,,, ~L ,,:ARPtlCANT'CERJJEl&A,TlON:,,, ~ ~:_ -;,v --~ :~-:-_,., 'V ',, ,; ; :-~--, -.,,,>,A'' ,' h -~r:;:;:;,:;;--::;r:{-~;: -~ 't?{''J!:-~~~~:-.--;:;~ }''~~~?_~_::;:~,~~
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cii:~ of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and. molition or construction of structures over 3 stories in height.
EXPIRATION: 'Every per t I sued by the buildin Off' ial under th rovisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permi 1s n~1r1m,lr#,,1at1ced wit 1 ays from e date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the wor ... f r p ri d (Section 106.4.4 Uniform Building Code). DATE -1-~-°'~,_,J.,.~~,_ _______ _
YELLOW: Applicant PINK: Finance
CIIY DI Carlsbad
; · Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite (E[i:E!
Plan Check #:
Permit#:
Project Name:
CB050939
CALLAWAY GO!-F
Date: 06/03/2005
Permit Type: Tl
Sub Type: INDUST
3,994 SF OFFICE TO OFFICE, BRAND MANAGEMENT
Address: 2180 RUTHERFORD RD. Lot: 0
Contact Person: BOB Phone: 6195200317
Sewer Dist: CA Water Dist: CA
I I 111111 I I II 1!~11111111 I 111IIIII1111111111111 I 11 I I I I I I I 111II111,11111 I II 1111 I I I I 11 I I I I I I I 11111111111 I 11 I I I I ii I I I 11 I I I I I I 11 I 1111I1111 I 11 I I I 111 I I I I I 11111 I II I I I
. Inspected -11r, ~-Date
~isapproved: __ By: . Inspected: Approved:
Inspected Date
By: Inspected: Approved: Disapproved:_· _
Inspected Date
By: Inspected: . Approved: Disapproved: __
I 1111111II11111 I I I I 111 I I I I I I I I ii 1111111_1111111 I 1111 I I I II I I 11 Iii 1111 II II 1111 I 11 I I I I II I I I I I 11111 I I 11I1111 I I I I I I I I I I I I I I I I 11 I I I II I 11 I II 111 I 11 I I 111 I I I I II II II 111
Comments: --------------------------------
City of Carlsbad Bldg Inspection Request
For: 06/_?,;112005
Permit# CB050939 7-L/ Inspector Assignment: TP ---
Title: CALLAWAY GOLF
DesGription: 3,994 SF OFFICE; TO OFFICE, BRAND MANAGEMENT
Type: Tl Sub Type: INDUST
Job Address: 2180 RUTHERFORD RD
Suite: Lot O
Location:
Phone:Q26
Inspector: .
APPLICANT SMITH CONSUL TING ARCHITECTS
Owner: CALLAWAY GOLF CO
Remarks:
Total. Time: Requested By:
Entered By:
CD Description Act Comment
19 Final Structural .A//
29 Final Plumbing ± 39 Final Electrical
49 Final Mechanical
Associated PCRs/CVs
PCR00003 ISSUED NEW SEISIMIC CALCULATIONS;
PCR01025 ISSUED CALLAWAY-REV FLOOR/CEILING; ANCHORS -SEISMIC
Inspection History
Date Description Act lnsp Comments
06/13/2005 89 Final Combo CO .TP SEE CARD
06/10/2005 89 Finl:1I Combo CA RB
06/07/2005 89 FinaJ Combo c;:o TP SEE JOB CARD
06/03/2005 89 Final Combo NR TP NEED FIRE FINAL
05/19/2005 14 Frl:!me/Steel/Bolting/Welding AP TP T-CEIL@ OFFICES
051rn1200.5 34 Rough Electric AP TP T-CEIL@ OFFICES LITES
05/19/W05 44 Rough/Ducts/Dampers AP TP RE-LOC DUCTS
05/18/2005 84-Rough Combo co TP T-CEIL
DOUGLAS
KAREN
05/03/2005 14 Frame/Steel/Bolting/Welding AP TP SOFT WALL FLR ATTCH. & BRACING
05/03/2005 17 Interior Lath/Drywall AP TP
04/29/2005 14 Frame/Steel/Bolting/Welding AP TP
04/29/2005 34 Rough Electric AP TP
EsGil Corporation
In Partnersliip 'Ulitli qovernment for 'Bui{aing Safety
DATE: 4/20/05 D~ANT
~
JURISDIGTION: City of Carlsbad D PLAN REVIEWER
D FILE
PLAN CHECK NO.: 05-939 ..
PROJECTADDRESS: 2180 Rutherford RD
SET:11
PROJECT NAME: Calloway Golf H.Q. Brand Management -TI
D
D
D
the plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building coqes.
the plans transmitted herewith will substantially compJy'with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check. list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck. ·
D . The applicant's copy of the check list is .enclosed fot the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ Esgil Corporation staff did not advise. the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the:applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax #:
Mail Telephone Fax. In Person
D REMARKS:
By: Doug Moody
Esgil Corporation
D GA D MB D l;J D PC
E:nclosures:
4/14/05
,,
... ~-
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (85f) 560-1468 + Fax (858) 560-1576
\ ,..)
EsGil Corporatio-n
In <Partnersliip witli .government for (}Jui(ain9 Safety
DATE: 4/6/05 CJ APPLICANT
JURISDICTION: City of Carlsbad ~ CJ PLAN REVIEWER
CJ FILE
PLAN CHECK NO.: 05-939 SET:I
PROJECT ADDRESS: 2180 Rutherford RD
PROJECT NAME: Calloway Golf H.Q. Brand Management -TI
D The plans transmitted herewith have been corrected where necessary and substantially comply
· with the jurisdiction's building codes.
D _ The -plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D
D
D
The plans transmitted herevvith have significant deficiencies identified on the enclosed check list
and should be corrected and r:_est,1bmitted for a complete recheck.
The check list transmitted herewith is for your infoi:mation. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check-list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Smith Consulting Architects/ Andrew Tarango
12220 El Camino Real Sut~e 200; San Diego, CA 92130
Esgil Corporation staff did not qdvise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person c~?~cte~~-Jn rew Tarango (vv0 -Telephone #: 858-793-4 777 y () l(J
Date~~ V, (by:~) Fax #: 858-793-4787
Mail./Telephone · Fax,./ In Person -
REMARKS:
By: Doug Moody
Esgil Corporation
D GA D MB D EJ D PC
Enclosures:
3/24/05 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, Califorhia 92123 + (858) 560-1468 + Fax (858) 560-1576
v '· ~
City of Carlsbad 05-939
4/6/05
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 05-939
OCCUPANCY: B / Fl
. .
TYPE. OF CONSTRUCTION: VN
ALLOWABLE FLOOR AREA:.
SPRINKLERS?: YES
-REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 3/22/05 .
DATE INITIAL PLAN REVIEW
COMPLETED: 4/6/05
FOREWORD (PLEASE READ):
JURISDICTION: City of Carlsbad
USE'.: Office
ACTUAL AREA: 3994s£
STORIES: 2
HEIGHT:
OCCUPANT LOAD: 47
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 3/24/05
PLAN REVIEWER: Doug Moody
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code., URiform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations en{orced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited· are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note. on this list (or a copy} where each
correction item has been addressed, 1.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when y~u submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot
City of Carlsba,d 05-939
4./6/05
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans an.d calculations/reports directly to the City of
Carlsbad Building· Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602.:.2700. The City Will. route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1-. Provide a ~ection view of all new interior partitions. Show:
a) · Method of attaching top and ,bbttom plates to structure. (Please revise the
spacing of the studs used for lateral bracing in detail 2 on A2 to show 4').
b) Show height of partition and suspended ceiling, and height from floor to
roof framing or floor framing
2. When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B.2. These
requirements apply as .follows:
a) A primary entrance to the building and the primary path of travel to the
altered area; must be shown to comply with all accessibility features.
b) Existing sanitary facilities that serve the remodeled area must be shown to
comply with all accessibility features.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet, note or detail number,
calculation page, ·etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please. ·ind ioate:
Yes CJ No CJ
City of Carlsbad 05-939
4/6/05
The jurisdiction has contracted With Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad 05-939
4./6/05 ·
jVALUATION AND P.LAN· CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: Doug Moody
PLAN CHECK NO.: 05-939
DATE: 4/6/05
BUILDING ADDRESS: 2180 Rutherford RD
BUILDING OCCUPANCY: B/Fl TYPE OF CONSTRUCTION: VN
BUILDING AREA Valuation Re_g. VALUE
PORTION (Sq.Ft.) Multiplier Mod.
Tl
. ,
3994 City Valuation
,
~
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit F.ee by .ordinance _-.,j
Plan Check ·Fee by Ordinance , ·,;,.,
' ,.,
Type of Review: 0 Complete Review D Structural Only
D Repetitive Fee
:~~ I R~peats
D Other
D Hourly · I Hour*
Esgll Plan Review Fee
Comments:
($)
123,814
123,814
$620.48!
$403.311
$347.471
Sheet 1 of 1
macvalue.doc
'PLANNINC/ENOINEERIN.G APPROVALS
PERMIT NUMBER CB. ('.) 5 -er. 31 · .. DATE ) -~ _lY-0.S'
ADDRESS_,,..·_;p_·l-_~ ___ .tJ......----,..""-/2_7vft __________ nL_~ __ ·· ___ t _______ k ____ ~---~--____ _
'Rl;SIDENTIAL ·
RESIDENTIAL ADDITION MINOR
( < $10.000.00}
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAC& FAIRE
COMPLETE OFFICE BUILDING
. OTHER--:---..i-,,:c:B;....::;~_;:,,,j ....... t4'?_,;;; __ ~_;;,,,___-=-~~"::;._;:CU>=--..... _--------,-----
DATE ~i>/4s I .
Carlsbad Fire Department 050939
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review
Fire Prevention
, Requirements Category:
Date of Report: _o:a_. 12_4_12_0_05 ____________ _
Building Plan
Rev:iewed by:
4 f;6024660
Name: SMITH CONSULT ARCH
Address: 12220 EL CAMINO REAL STE 200
City, State: SAN DIEGO CA 92130
Plan Checker: Job #: 050939 -------
Job Name: Callaway Golf Bldg #: CB050939 --------------------------
Job Address: 2180 Rutherford Rd Ste. or Bldg. No.
~ Approved
D Approved
Subject to
D Incomplete
Review
FD Job#
The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
The item you have submitted for review h~s been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report <?an result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and I or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and/ 9r specifications to this
office for review and approval.
1st
050939
2nd
FD File#
3rd Other Agency ID
• •
J0rE' Fez. ,.t,.:ri,.:,..u.\,Vd:.1-.tr--ro·ME'.IAL-
'R,coF" VE.G-1::.., SEE.. "Sl<.-(.o
--f---1 ''si-ttL.C.ASE.. Quone:.tJr"
I 'c-r ~rno,.J
t=--=-I I =-~ -· --
I I ™EL-7o I ~E,(._.
I I j-:J"~
J L_ ,-= --=j r . ' -
±,
. . ;
STEELCASE "QUOTIENT" PARTITION PANEL ELEVATION
Degenkolb Engineers
225 Bush Street, Suite 1000
S~n Frani:;isco, CA 94104-4207
Phone 415.392.6952 Fax 415.981.3157
Title: Steelcase Pathways Quotient
Wall Anchorage Details. Sheet Number
Drawn: SMG Job No.:98484.00 SK-1
Design: TMS Rev.:
· Date: JI /-2/oy Check:
Job: Steelcase-Callaway Golf Project
Carlsbad, CA
: .. ;:-~ i~;?i· ~
-'\:·,,
. :;-.-,. ••
A ---
---~ ~,-,
r 1,0' I L.,. I
' !n1. I ..__
------
A
--,=-,=, -~rr; ,--
----i,__;,.._I --. !. I
:::.
----
.,· .. :.:/, .. •--~
A-A
STEELCASE "QUOTIENT" PARTITION TOP TRACK CONNECTION
Degenkolb Engineers
225 Bush Street, Suite 1000
San Francisco, CA 94104-4207
Phone 415.392.6952 Fax 415.981.3157
. Title: Steelcase Pathways Quotient
Wall Anchorage Details.
Drawn: SMG Job No.:98484.00
Design: TMS Rev.:
Check: Date: II /z /bt./
Sheet Number
SK-2
Job:· Steelcase-Callaway Golf Project
Carlsbad, CA
___ ,, .. ·--· ----------------
•
i L1~1Sf12LJT"" PleA-"7
Av.rusr p..i=,l.e..
µ1~1::.-
•
LATERAL BRACE ANCHORAGE DETAIL AT SOFFIT SLAB
Degenkolb Engineers
225 Bush Street, Suite 1000
San Francisco, CA 94104-4207
Phone 415.392.6952 Fax 415.981.3157
Title: Steelcase Pathways Quotient
Wall Anchorage Details. Sheet Number
Drawn: SMG Job No.:98484.00 SK-3
Design: TMS Rev.:
Clleck: Date: J I / -z lot/
Job: Steelcase-Callaway Golf Project
Carlsbad, CA
BASE TRACKANCHORAGE DETAIL AT FLOOR SLAB
Degenkolb Engineers
225 Bush Stree~. Suite 1000
San Francisco, CA 94104-4207
Phone 415.392.6952 Fax 415.981.3157
Title: SteelCase Pathways Quotient
Wall Anchorage Details. Sheet Number
Drawn: SMG Job No.:98484.00 SK-4
Design: TMS Rev.:
Check: . Date: 11 /-z lot./
Job: Steelcase-Callaway Golf Project
Carlsbad, CA
•
1/t 11tP~·
L£'v€u:kf2&
B~>0JO
'3/a11¢M.B.
w/,Jur{A-0
ltJ.b-.6Hr~
BASE TRACK ANCHORAGE DETAIL AT. "TATE" ACCESS FLOOR
Degenkolb Engineers
225 Bush Street, Suite 1000
San Francisco, CA 94104-4207
Phone 415.392.6952 Fax 415.981.3157
Title: Steelcase Pathways Quotient
Wall Anchorage Details. Sheet Number
Drawn: SMG Job No.:98484.00 SK-5
Qesign: TMS Rev.:
Check: Date: J J /,z. lo'/
Job: SteelCase-Callaway Golf Project
Carlsbad, CA
•
...,---------------~~~LA.-rio~ 0/eR-
M~AL.-i76:..k...
I
I
I • I
p..·
11UJ1sfie.u-(" PieA-1 ~-
,6.';iZ!L..lS"t.b."E::<..:E. U I J ~ £.
+
r --;
1-.--t"J
+
+
)4 ~tc.~.:)dZ . .., -:5(:Q. "Slt=.E.L-
~E.,
LATERAL BRACE ANCHORAGE DETAIL AT METAL DECK ROOF
Degenkolb Engineers
225 Bush Street, Suite 1000
San Francisco, CA 94104-4207
.aiiAiii:~~lilill. Phone 415.392.6952 Fax 415.981.3157
Title: Steelcase Pathways Quotient
Wall Anchorage Details. Sheet Number
Drawn: SMG Job No.:98484.00 SK-6
Desigo: TMS Rev.:
Check: Date: // / ,z.. Jot/
Job: Steelcase-Callaway Golf Project
Carlsbad, CA
·.
\
-.:--:-------------/-::r:J~~--rioiJ ~
ME:f'A'-i7e:.c..k..
~
13~NO .s-ruD wC"e,
J -rA~;ff r--l 10 Fl w/
4-fto G~fE"1 Mf1At...
5e,,~v-J5,
+
+
i·-
·[;j+ 1 + .j..'
. '
1-
'A 41tiuc.. '12..Q "S(Q. Si~
~c.,
Lateral Brace Anchorage Detail at Metal Deck Roof
Degenkolb Engineers
225 Bush Street, Suite 1000
San Francisco, CA 94104-4207
Phone 415.392.6952 Fax 415.981.3157
Title: Lateral Brace at Roof Sheet Number
Drawn: TMS Job No.:99522.00 SK-6R
Design: TMS Rev.:.
Check: SMG Date: / I /.z /o t/
Job: Steelcase-Callaway Golf
. ~ <
·. -·
* .... ~, .. .. ... . . . ______ ,_ .. , "'.... ' ., .. , ........ . .., '
4-'vJ ~ ~ \B bo. f-lrr'-•
. S-rtJt::> ~~ \ 41:.. 0 11
o tJ ~it...rftf',1. ., eeMove..
~~ 2,·~o
~$ ~ ~. ~,Jv. .#··.i b
••
4-----~~-
::.(.
11t.Mt...o~ro 11 ·
QUof1~ . fp.,"1E1,
.--.-,._.~or-r~
'· A.-~
~s·.
\: f'~ Ait.A'-'UMe.Jf -ro
~o~ oJEJi!!..
fl',e(~ ~, use:.
2-~ \0 cs,,,-. 4S . "111.~
f./((L , ~UD v.Je,13, irJ-ro
,vttt_. ~-l9~+~:
(_..d_!J l I • .
STEELCASE "QUOTIENT" PARTITION BRACING DETAIL
Degenkolb Engineers
225 Bush Street, Suite 1000
San Francisco, CA 94104-4~07
Phone 415.392.6952 Fax 415.981.3157
Title: Steelcase Pathways Quotient
Wall Anchorage Details.
Drawn: TMS Job No. 98484.00
Design: TMS Rev.:
Check: Date: 11 I z. lot/
Job: Callowa)' Golf Project
Sheet Number
SK-1