Loading...
HomeMy WebLinkAbout2190 CHESTNUT AVE; ; CB072931; Permit09-08-2008 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB072931 Building Inspection Request Line (760) 602-2725 2190 CHESTNUT AV CBAD RESDNTL Sub Type 1670703100 Lot# $29,484 00 Construction Type Reference # 0 Structure Type 0 Bathrooms FINN RES- BUILD NEW 1,001 SF DETACHED GARAGE RAD 0 NEW Stati Appliei Entered By Plan Approved Issued Inspect Area Orig PC# Plan Check# WITHDRAV D7 LSM Applicant FINN FAMILY TRUST 10-21-06 Owner FINN FAMILY TRUST 10-21-06 2190 CHESTNUT AVE CARLSBAD CA 92008 7607126545 2190 CHESTNUT AVE CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $265 05 Meter Size $0 00 Add'l Reel Water Con Fee $17228 Meter Fee $19200 SDCWAFee $0 00 CFD Payoff Fee $295 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic I mpact Fee (4305541) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee $0 00 Housing Credit Fee Master Drainage Fee $0 00 Sewer Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $3400 $2000 $000 $000 $000 $000 $000 $000 $000 $686 28 Total Fees $686 28 Total Payments To Date $17228 Balance Due $51400 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any tees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired City of Carlsbad 1635 Faraday Ave , Carlsbad CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 Building Permit Application Plan Check No Est Value Plan Ck Deposit Date iv JOB ADDRESS , I -, z.!3£> Ck^t^H. JWv/>u^CT/PROJECT #LOTH PHASE 0 1 f OF UN'ITS 1 » BEDROOMS SUITE«/SPACE*t/UNIT» tt BATHROOMS ((07-010 -3 I -00 TENANT susiMESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YES D # NO D AIR CONDITIONING YES D NOD FIRE SPRINKLERS YES D NO D 1 CONTACT.NAME (If Different Fom Applicant)! .ADDRESS APPLICANT NAME CONTRACTOR BUS NAME ADDRESS" (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter improve demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}) Workers'Compensation Declaration I hereby affirm under penalty of per/ury one of the following declarations 6^U£.r~ Dol\A/>/^ / /I//1 S> y*^ vO<? ^ n I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for Ihe performance of lite work for which this permit is issued n I have and will maintain workers' compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers compensation insurance carrier and policy number are Insurance Co Policy No Expiration Date This section need not be completed if the permit is for one hundred dollars (S100) or less D Certificate of Exemption I certify that in Ihe performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000). in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney s fees ^"CONTRACTOR SIGNATURE DATE / hereby affirm that I am exempt from Contractor s License Law for the following reason Jf I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold withm one year of completion Ihe owner builder will have the burden of proving that he did not build or improve for the purpose of sale) D I as owner of Ihe property am exclusively contracting with licensed contractors to construct Ihe project (Sec 7044 Business and Professions Code Thn Contractor? License I w does not apply to an owner of properly who builds or improves Ihereon and contracts for such projects with conlractor(s) licensed pursuant to the Contractor s License Law) CI I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Cl Yes n No 2 I (have / have not) sianed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / ohone / contractors license number) 4 I plan to provide portions of the work 5 I will p'ovide some of the e following person to coordinate supervise and provide Ihe major work (include name / address / phone / contractors license number) lowing persons to provide Ihe work indicated (include name / address / phone / type of work) Is the applicant or future building occupant reqwed to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of Ihe Presley Tanner Hazardous Substance AccounrAct' CI Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 D Yes D No Is the facility to be consisted wilhm 1 000 feet of Ihe outer boundary of a school site' l~1 Yes CT No IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT SE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT .j^i v^jljLj £ •/U, ,xt! CiV J I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender s Name Lender s Address i I certify that I have read the application and state that the above mfotmation is cotrcct and (hat the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the Buildipg-QfftcTaTTJiyler the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if Jiebuilding^pr wojk^uthonzed by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code)i «u days from me date ot sucn permit ( N^e APPLICANT S SIGNATURE i PATE City of Carlsbad Building Department September 3, 2008 REGIS FINN 2190 CHESTNUT AVE CARLSBAD CA 92008 RE: APPLICATION DATE 11/26/2007 PLAN CHECK # CB07 2931 ADDRESS EXPIRATION DATE PERMIT TYPE DESCRIPTION 2190 CHESTNUT AV 11/25/2008 RES BUILD NEW 1,001 SF DETACHED GARAGE You applied to have your plans checked on the date noted above To date, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee " In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department Project Abandoned -1 will pick up the plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2719 Building Department CC 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (76O) 602-27OO • FAX (760) 602-856O EsGil Corporation In Partnership with government for (BuiCifing Safety DATE 02/25/2008 a APPLICANT JURIS, JURISDICTION City of Carlsbad '^TrPTANlREVIEWER a FILE PLAN CHECK NO CB072931 REV 1 SET I PROJECT ADDRESS 2190 Chestnut Ave. PROJECT NAME Detached Garage for the Finn Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Regis Finn 2190 Chestnut Ave Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Regis Finn Telephone # (760) 712-6545 Date contacted (by ) Fax # None Provided Mail Telephone Fax In Person !X] REMARKS Correct the shear wall number on page 3 wall line "1" clouded in red from 2 to 3 per the engineering By Aaron Goodman Enclosures Esgil Corporation D GA D MB D EJ D PC 02/19/2008 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 .City\>f Carlsbad CB072931 REV 1 02/25/2008 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO CB072931 REV 1 PREPARED BY Aaron Goodman BUILDING ADDRESS 2190 Chestnut Ave. DATE O2/25/20O8 BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING PORTION Garage Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Valuation Multiplier By Ordinance Reg Mod VALUE ($) Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review ^Repetitive Fee Repeats D Complete Review D Other m Hourly $240 00 Structural Only Hours * Esgil Plan Review Fee $19200 * Based on hourly rate Comments Sheet 1 of 1 macvalue doc EsGil Corporation In (Partnership -with government for (BuiCding Safety DATE December 4, 2007 oj\PPUQANT JURISDICTION City of Carlsbad O~PLANREVIEWER a FILE PLAN CHECK NO CB072931 SET I PROJECT ADDRESS 2190 Chestnut Ave. PROJECT NAME Detached Garage for the Finn Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck 2S| The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Regis Finn 2190 Chestnut Ave Carlsbad, CA °\^ OO B Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Regis Finn Telephone # (760)712-6545 Date contacted uJ(/iQ'7 (byMS} Fax # None Provided / ' Mail ^Telephone l/-Fax In Person REMARKS By Steve Sanders Enclosures Esgil Corporation D GA D MB D EJ D PC 11/27/07 9320 Chesapeake Dm e, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad CB072931 December 4, 20O7 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO CB072931 JURISDICTION City of Carlsbad PROJECT ADDRESS 2190 Chestnut Ave. FLOOR AREA Garage 1092 sq ft REMARKS DATE PLANS RECEIVED BY JURISDICTION 11/26/07 DATE INITIAL PLAN REVIEW COMPLETED December 4, 2007 STORIES 1 HEIGHT 19'-0" DATE PLANS RECEIVED BY ESGIL CORPORATION 11/27/07 PLAN REVIEWER Steve Sanders FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e , plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad CB072931 December 4, 2O07 Important Notice Regarding the 2007 CBC If you are an architect, engineer, designer or contractor that performs work within the State of California, please be advised that a new building code will take effect on January 1, 2008 The new building code is based on the 2006 International Building Code (IBC) and it is significantly different than the Uniform Building Code (UBC) All plan review applications submitted after December 31, 2007 will be required to comply with the new code The 2007 CBC is currently available for purchase directly from the International Code Council, at www iccsafe org Please make all corrections, as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 2 Specify on the Title Sheet of the plans the gross floor area of each element of this project Section 106 3 3 3 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbmg/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC 4 Specify roof slope The plans show the roof pitch as 3/2. Is this supposed to read 3 :12 ? Please clarify City of Carlsbad CB072931 December 4, 2007 5 Show method bracing garage front and holddowns if required Chapter 16 NOTE Maximum shear panel height-to-width ratio is 31/2 -to-1 for plywood Table 23-ll-G In Seismic Zone 4, this 31/2-to-1 ratio is only permitted in one-story garages with a wall height not exceeding 10 feet It appears the front of the proposed garage does not meet the above requirement Structural calculations are required for this proiect 6 Note on plans that surface water will dram away from building and show drainage pattern Section 1804 7 7 Note on plans that wood shall be 6" minimum above finish grade Section 18061 8 Dimension foundations per U B C Table 18-l-C Floors Footing Supported* Thickness Width Depth Stemwall 1 6" 12" 12" 6" Please show the width of the footing on detail %. 9 Show foundation sills to be pressure treated, or equal Section 2306 4 10 Show foundation bolt size and spacing Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan Section 1806 6 11 The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per Section 18066 1 a) The minimum nominal anchor bolt diameter shall be 5/8-inch (for Seismic Zone 4 only) Note This will require a minimum distance from the ends of sill plates to be 4-3/8" (and a maximum of 12") b) Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each anchor bolt 12 If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection Section 108 5 2 13 Show double top plate with minimum 48" lap splice Section 2320 112 14 Show nailing will be in compliance with Table 23-II-B-1 15 Provide truss details and truss calculations for this project Specify truss identification numbers on the plans City of Carlsbad CB072931 December 4, 20O7 16 Detail shear transfer connections, including roof diaphragms, to shear walls Section 2315 17 Provide calculations for lateral loads, shear panels, shear transfer and related Section 10633 18 Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations (California Business and Professions Code) 19 Specify plywood and/or particle board thickness, grade and panel span rating Table 23-II-E-1 20 Show on the plan that ground-fault circuit-interrupter protection complies with NEC Art 210-8, which reads as follows All 125-volt, single-phase, 15- and 20- ampere receptacles installed in garages 21 Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement) a) In garages all fixtures must be high efficacy style or be controlled by a manually-on occupancy sensor b) Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor Note Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts Regular incandescent, quartz halogen and halogen MR lamps do not comply City of Carlsbad CB072931 December 4, 2O07 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Steve Sanders at Esgil Corporation Thank you City of Carlsbad CB072931 December 4, 2007 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PREPARED BY Steve Sanders BUILDING ADDRESS 2190 Chestnut Ave. PLAN CHECK NO CB072931 DATE December 4, 2007 BUILDING OCCUPANCY U-l TYPE OF CONSTRUCTION VN BUILDING PORTION Garage Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 1092 cb Rlrln Pprmit- FPP hv Ordinance i "V Valuation Multiplier 2793 By Ordinance Reg Mod VALUE ($) 30,500 30,500 $271 11 Plan Check Fee by Ordinance Type of Review l~1 Repetitive Fee '~^~j Repeats Complete Review D Other i—I Hourly Structural Only Hour* Esgil Plan Review Fee Comments $17622 $151 82 Sheet 1 of 1 macvalue doc City of Carlsbad Public Works En g i n e e r i n g BUILDING PLANCHECK CHECKLIST DATE BUILDING A PLANCHECK NO CB PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER //£7-<ff7#-3/ ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements EST VALUE DENIAL Please seeNthe^attached report of deficiencies marked withJ3KTv1ake necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By Date Date Date By ; FOR OFFICIAL USE ONLY NGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date (ATTACHMENTS'— D Dedication Application D Dedication Checklist D Improvement Application D Improvement Chi D Neighborhood Irn D Grading Permit ft D Grading Submittc D Right-of-Way Pei [] Right-of-Way Pei and Information 5 D Storm water App ENGINEERING DEPT CONTACT PERSON Name JOANNE JUCHNIEWICZ City of Carlsbad Address 1635 Faraday Avenue, Carlsbad, CA 92008 3O) BUILDING PLANCHECK CHECKLIST SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A B C D North Arrow Existing & Proposed Structures Existing Street Improvements Property Lines Easements - F Right-of-Way Width & Adjacent Streets G Driveway widths H Existing or proposed sewer lateral I Existing or proposed water service J Existing or proposed irrigation service n Show on site plan /A~jDrainage Patterns --- 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION F \BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST 3RD D DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No D 4b All conditions are in compliance Date DEDICATION REQUIREMENTS D 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17,000 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 V* x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date D IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST 1ST 2N D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date D 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $430 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows D D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy D D nan GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15 16 010 of the Municipal Code 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial) This information must be included on the plans. r 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST ..ST/^pND b( n RD3 D D 7d No Grading Permit required 7e If grading is not required, write "No Grading" on plot plan D D D MISCELLANEOUS PERMITS 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities Right-of-Way permit required for INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7138, for assistance Industrial Waste permit accepted by Date 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first 10 a STORM-WATER APPLICABILITY CHECKLIST D Requires PSWP (project storm water permit) # Not required 11 FEES Q Required fees are attached J/)xNo fees required F \BU1LDING PLANCHECK CKLST FORM doc •>RD BUILDING PLANCHECK CHECKLIST WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) 12b Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" service and 5 meter (estimated 100 gpm) 2 If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection F \BUI1_DING PLANCHECK CKLST FORM doc 1ST ,ND BUILDING PLANCHECK CHECKLIST 3 In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is . there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this 13 Additional Comments- F \BUILDING PLANCHECK CKLST FORM doc 1 U pJ N to —mo r 33 y, legi "»il*"2 -yu< ex * i -"f jfi*i:; 111*' m O -n 3£S, sssl\"ts lir* F"r_sSS °0 m O z « O — TJ > O > O O 33H r- m - i I <ior j^ = ' 5 M? — o-z o aj(/) o m O o 0 o I ^ Kr±: X Oo > * H -5 r>c *L> °Z!o P o O m ons-< z -i z t™ -I, O1"S o>- »« -S 0 tn t* i.m m n *".° ^O« m O oI 3J -n -n 2 §"o§ o tunwiN AS rt ^iai^H3*^3 cmv wvi <T««• Ia 3 SZ 22C^ (^ <T3a a Q 00a O O U _ra jo a a KID D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB 0 1'Address grl Planner Chris Sexton Phone (760) 602-4624 APN \1n1~010-3l Type of Project & Use iO€uJ ( Zoning &~n~ I^QeTieral Plan N mt£#fun) CFD (irt7out)"£) Date of participation I' Net Proiect Density / O Facilities Management Zone / Remaining net dev acres DU/AC Circle One (For non-residential development Type of land used created by this permit ) Legend Item Complete Environmental Review Required DATE OF COMPLETION Item Incomplete - Needs your action YES _ NO \/ TYPE _ Compliance with conditions of approval9 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/PESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval9 If not, state conditions which require action Conditions of Approval D D SD D B.D Coastal Zone Assessment/Compliance Project site located in Coastal Zone9 YES_ CA Coastal Commission Authority9 YES_ NO NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed9 YES NO If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') Inclusionary Housing Fee required YES NO (Effective date of Inclusionary Housing Ordinance May 21, 1993 ) Data Entry Completed9 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan [~| Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number D D D Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES NO / 2 Project complies YES Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope 2 Accessory structure setb Front Interior Side Street Side Rear Structure separation • v NO Required ^ Required / Required ,/ Required s Required ' lacks Required Required ~~ff f~> ' Required Required /55' Required /O' * Shown Shown Shown ^^^ Shown ^"^ Shown ^^ Shown Shown 7 *r} Shown Shown 15' Shown -jfr1 J-/9-F 3 Lot Coverage 4 Height Required ^^70 7"Shown H 0 7 Required Spaces Required. Shown Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required ^"^ ok^. Additional Comments CrQKfl. A (O1 OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRovChklst Rev 3/06 MiTek POWER TO PERFORM• Re 08-1002 FINN MiTek Industries, Inc. 7777 Greenback Lane Suite 109 Citrus Heights CA 95610 Telephone 916/676 1900 Fax 91 6/676 1909 The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc under my direct supervision based on the parameters provided by Dixielme Lumber Co -National City, CA Pages or sheets covered by this seal R27523516 thru R27523517 My license renewal date for the state of California is March 31, 2009 January 3,2008 Tmgey, Palmer The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-2002 Chapter 2 r08-1002 Truss T01A Truss Type GABLE Qty 1 Ply 1 FINN R27523516 Job Reference (optional) Dixielme Lumber(Cp() National City CA I 2ifi_ 8 500 $ Apr 2 2007 MiTek Industnes Inc. Wed Jan 02 09^g2 2008 Page 1 70-10 5-11-6 70-10 20-0 Scale = 1 48 9 3x6 : 4x7 300(12" 1 9-0-7 9-0-7 1 16-11 9 711 3 X-o-o 9-0-7 Plate Offsets (X.Y). [4.0 3-0.0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 200 140 00 100 SPACING Plates Increase Lumber Increase Rep Stress Incr 2-0-0 1 15 1 15 YES Code IBC2006/TPI2002 CSI TC BC WB 044 078 036 (Matrix) DEFL Vert(LL) Vert(TL) HorzfTL) in (loc) -020 810 0 73 2 10 016 6 l/defl >999 >420 n/a Ud 240 180 n/a PLATES MT20 Weight 127lb GRIP 220/195 BRACING TOP CHORD Structural wood sheathing directly applied or 3-2-5 oc purlins BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing LUMBER TOP CHORD 2X4DFNo1&BtrG BOT CHORD 2X4DFN02G WEBS 2 X 4 DF Stud/Std G OTHERS 2 X 4 DF Stud/Std G REACTIONS (Ib/size) 2=1280/0-3-8 6=1280/0-3-8 Max Horz 2=49(LC 4) MaxUplift2—127(LC6) 6=-127(LC 7) FORCES (Ib) Maximum Compression/Maximum Tension TOP CHORD 1 2=0/32 2 3=-3372/375 3-4-2956/296 4-5-2956/296 5-6=-3372/375 6-7=0/32 BOT CHORD 2 10= 294/3211 9-10= 169/2216 8-9-169/2216 6-8= 294/3211 WEBS 3-10=-534/163 4-10=0/809 4-8=0/809 5-8=-534/163 NOTES 1) Unbalanced roof live loads have been considered for this design 2) Wind ASCE 7-05 90mph h=25ft TCDL=6 Opsf BCDL=6 Opsf Category II Exp B enclosed MWFRS gable end zone and C C Extenor(2) zone cantilever left and nght exposed end vertical left and nght exposed Lumber DOL=1 60 plate grip DOL=1 33 This truss is designed for C C for members and forces and for MWFRS for reactions specified 3) Truss designed for wind loads in the plane of the truss only For studs exposed to wind (normal to the face) see Standard Industry Gable End Details as applicable or consult qualified buildmg designer as per ANSI/TP11 2002 4) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads 5) All plates are 2x3 MT20 unless otherwise indicated 6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection 7) Gable studs spaced at 1-4-0 oc 8) * This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2 0-0 wide will fit between the bottom chord and any other members 9) A plate rating reduction of 20% has been applied for the green lumber members 10) This truss is designed in accordance with the 2006 International Building Code section 2306 1 and referenced standard ANSI/TP11 LOAD CASE(S) standard January 3 2008 Jj^ WARNING Verify daaign parameters and READ NOTES OK THIS AND INCLUDED &T&K REFERENCE PAGE IOI 7473 BEFORE USB. Design valid for use only with MiTek connectors This design a based only upon parameter* shewn and is (or an individual building component Applicability of design paramenrers and proper incorporation of component is responsibility of building designer not truss designer Bracing shown is for lateral support of individual web members only Additional temporary bracing to insure stability during construction is the responsibility of the erector Additional permanent bracing of the overall structure is the responsibility of the building designer For general guidance regarding fabrication quality control storage delivery erection and bracing consult ANSI/TP11 Quality Criteria DSB-S9 and BCS1T BuOdlna ComponentSafety Information available from Truss Plato Institute 583 D Onofno Dnve Madison WI53719 if POWCH TO PtCTrOBtt 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Job 08-1002 Truss T01B Truss Type FINK Qty 1 Ply 1 FINN R27523517 Job Reference (ootional) Dojeline Lumber^jo^ National City CA 2-0-0 . 70-10 6 500 s Apr 2 2007 MiTek Industries Inc Wed Jan 02 09£gjj3 2008 Page 1 h 2-0-0 70-10 20-0 Scale = 1 48 9 0-0-0 [_ 9-0-7 9-0-7 LOADING (psf) TCLL TCDL BCLL BCOL 200 140 00 100 SPACING Plates Increase Lumber Increase Rep Stress Incr 2-0-0 1 15 1 15 YES Code IBC2006/TPI2002 CSI TC BC WB 16-11 9 7 11 3 044 078 036 (Matnx) DEFL Vert(LL) VertfTL) Horz(TL) in -020 -073 016 (loc) 8 10 2 10 6 I/deft >999 >420 n/a 0-04 26-0-0 ,I 9-0-7 L/d 240 180 n/a PLATES GRIP MT20 220/195 Weight 99 Ib BRACING TOP CHORD Structural wood sheathing directly applied or 3-2-5 oc purlins BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing LUMBER TOP CHORD 2X4DFNo1&BtrG BOT CHORD 2X4DFN02G WEBS 2 X 4 DF Stud/Std G REACTIONS (Ib/size) 2=1280/0-3-8 6=1280/0-3-8 Max Horz 2=49(LC 4) Max Uplift2= 127(LC 6) 6=-127(LC 7) FORCES (Ib) Maximum Compression/Maximum Tension TOP CHORD 1 2=0/32 2 3=-3372/375 3-4-2956/296 4-5—2956/296 5-6=-3372/375 6 7=0/32 BOT CHORD 2 10= 294/3211 9 10= 169/2216 8-9=-169/2216 6-8= 294/3211 WEBS 3 10= 534/163 4-10=0/809 4-8=0/809 5-8=-534/163 NOTES 1) Unbalanced roof live loads have been considered for this design 2) Wind ASCE 7 05 90mph h=25ft TCDL=6 Opsf BCDL=6 Opsf Category II Exp B enclosed MWFRS gable end zone and C C Extenor(2) zone cantilever left and right exposed end vertical left and right exposed Lumber DOL=1 60 plate grip DOL=1 33 This truss is designed for C C for members and forces and for MWFRS for reactions specified 3) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection 5) This truss has been designed for a live load of 20 Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2 0-0 wide will fit between the bottom chord and any other members 6) A plate rating reduction of 20% has been applied for the green lumber members 7) This truss is designed in accordance with the 2006 International Building Code section 2306 1 and referenced standard ANSI/TP11 LOADCASE(S) Standard \January 3 2008 ^^ WARNING Verify design paramatan and READ NOTES ON THIS AND INCLUDED gOT&K REFERENCE PAGE XD-7473 BEfOKB USE Design valid for use only with MiTek connectore This design e based only upon parameters shown and is for an individual building component Applicability of design paramenters and proper incorporation of component is responsibility of building designer not truss designer Bracing shown is for lateral support of individual web members only Additional temporary bracing to insure stability during construction is the responsibility of the erector Additional permanent bracing of the overall structure is the responsibility of the building designer For general guidance regarding fabrication quality control storage delivery erection and bracing consult ANSI/TPI1 Quality Criteria DSt-89 and BCSI1 BuBdlng ComponentSafety Information available from Truss Plate Institute 583 D Onofrio Drive Madison WI53719 ifpawca ro * eraaM 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 o i.c CD 1"^. CD a 5ID pa WE.MiTek Eng3 *O1 3<a •..x aa mo »•* ^1* sa ij V HJ? S8 * s= S 3 CDQ > =f Coro ^ a. ~~ tso co n ~° -7 2c m cf ™ J^ O§ »al Design Specification foronnected Wood Truss CorStandard for Bracing3 Component Safety Inforr1 II i 2.0 Q 3 ^m ^^^^^p38(FB?r.""1 ts> O ^O OO Use of green or treated lumber may pose unacceptenvironmental health or performance risks Consultproject engineer before useReview all portions of this design (front back wordsand pictures) before use Reviewing pictures aloneis not sufficientDesign assumes manufacture in accordance withANSI/TPI 1 Quality Cntena^&sf .— -s yl 1^i /v 1 " 1 M/ 5 \ ^. S x *• ii^8 \\| i Ml II ^ v S s§= on« = agcS^^ rp.9"2 « ^x$=? Sa fi CD 5 |Rp afy^ 5 *S|° f? §£?JaEa s^e. o ga^s 8S 03^ •^SacD 2. SCD > ^g53- B. Q.o.§ life? a!il 1 i|S| | litcDoga ^0-4? z Q|§i ^ as-o- S^I° ° n o- cfa-§"| 5 "SoR an ^ S3 o Sig CD ^ ? o CD" II I III Mi* i siOWQ— -«-;4-< wr^Q."D ^ R 0^5 CD 3o=> Eno o13^gi fat -&*CD n -*it^ 5 3-0 c « " | P II II ® >O21'Om PS"" ZO i^ J> ^r Sfci- £ § •" K°5 °°fti to (/i t~ 2! o Z3 ^~Qn^'o— ^,5 S*'* o> ?• ^ ~* ^ 3 ^^ "'S<jo2Wrn TJ/^ mZ m^*f^m — •(/> n*' ^3^ _:M*?3^rt';D T_O "*< 53 2^O'XJi 3?"f5 JO^ C^ 9s o- CN co m ^S *2?5 o°QS •—• "sj Cn *t. ^ » O>j >jo > > gp ^ g S S 3 ™ gz o @ ^ fe i 1 II n8 5 6 > | Si S S 2 8 " 1 aS §2 S 2 » ™> S i > m ™ 53 > o ?° (5 5 SR3 aS m °SiL) m (Tj 3 0, > / /VFor 4 x 2 orientation locaiplates 0- >/\i from outsideedge of trussCD ' 1 1 Wl ^— P1 /Vv rg ^ O1 ^ ^.^ J <~s S <"^ s <—^ 5 3^20"^ 5 oJ o s-z </> ». Q > D 0 O > 3-D 5 5=CD z^•agcSa o?•< 3 ETCD ^"§§R^ gCD a^ CD cf =3 (D "• = =* 35-"" Q 2 CD ZlosRo 5 aCT5 Q^ =! cTarrCD0, O CD =r,L a2- Z 3=g •? cII i- O in s D^ 5w to X •< TOP CHORD Cl-8 ^ '// W27 \ ^\\ ^ W3-6 X S.X I f/ n 2 — o-t)o SM o</l f /l\jy z cr 3 s 1 (D a 2. ^2 (O 3° *" II </> 1 o S (D i "<i (^ | S" s 3 (D (D D— -V/ ^C4-5 / /i. £ TOP CHORD — —— — — — — — -OOO^J O^ •^JO*Ui*.O> »O— O1 1° § ji s* in ii PI ii ii n mB 1M is it II? ^ hi is is I? IBS MM i! S i 11 It! « « I! R!I 1 ' !! II !* 11 10 U II |l fif| 5 r n s Is |s |j| p S| If Hi 111! 1 P I 1 II IS -U8. « 1 f! ^ 5? 1= ^§ |o 5^ rs a8a Ifi2 S s 2.| s§ 0.5=0 3- o^J o 1 s3 & D^^S-e-oscas ! fill I l IMM 1 2 S a<i ° 1? 3£--, cro C71 ^w ro —Additional stability bracing for truss system e gdiagonal or X bracing is always required SeeBCSITruss bracing must be designed by an engineer Forwide truss spacing individual lateral braces themsemay require bracing or alternative T 1 or Eliminatorbracing should be consideredNever exceed the design loading shown and neveistack matenals on inadequately braced trussesProvide copies of this truss design to the buildingdesigner erection supervisor property owner andall other interested partiesCut members to bear tightly against each other7 - *" °o 1^.k General Safety 1nlure to Follow Could Cause Prop3mage or Personal Injury(D 4£ ^ O o STORM WATER REQUIREMENTS APPLICABILITY CHECKLIST Project Address Assessors Parcel Number(s) ~ 31 Project # (city use only) Complete Sections 1 and 2 of the following checklist to determine your project's permanent and construction storm water best management practices requirements This form must be completed and submitted with your permit application Section 1 Permanent Storm Water BMP Requirements If any answers to Part A are answered "Yes," your project is subject to the "Priority Project Permanent Storm Water BMP Requirements," and "Standard Permanent Storm Water BMP Requirements" in Section III, "Permanent Storm Water BMP Selection Procedure" in the Storm Water Standards manual If all answers to Part A are "No," and any answers to Part B are "Yes," your project is only subject to the "Standard Permanent Storm Water BMP Requirements" If every question in Part A and B is answered "No," your project is exempt from permanent storm water requirements Part A Determine Priority Project Permanent Storm Water BMP Requirements Does the project meet the definition of one or more of the priority project categories7* 1 Detached residential development of 10 or more units 2 Attached residential development of 10 or more units - - 3 Commercial development greater than 100,000 square feet 4 Automotive repair shop 5 Restaurant 6 Steep hillside development greater than 5,000 square feet 7 Project discharging to receiving waters within Environmentally Sensitive Areas 2 8 Parking lots greater than or equal to 5,000 ft or with at least 15 parking spaces, and potentially exposed to urban runoff 9 Streets, roads, highways, and freeways which would create a new paved surface that is 5,000 square feet or greater Yes - Nox >< X X * *X X X * Refer to the definitions section in the Storm Water Standards for expanded definitions of the priority project categories Limited Exclusion Trenching and resurfacing work associated with utility projects are not considered priority projects Parking lots, buildings and other structures associated with utility projects are priority projects if one or more of the criteria in Part A is met If all answers to Part A are "No", continue to Part B Part B Determine Standard Permanent Storm Water Requirements Does the project propose ^f^^\ 1 New impervious areas, such as/rooftops>'roads, parking lots, driveways, paths and sidewalks'? \_ .-/ 2 New pervious landscape areas and irrigation systems? 3 Permanent structures within 100 feet of any natural water body? 4 Trash storage areas? 5 Liquid or solid material loading and unloading areas? 6 Vehicle or equipment fueling, washing, or maintenance areas? 7 Require a General NPDES Permit for Storm Water Discharges Associated with Industrial Activities (Except construction)?* 8 Commercial or industrial waste handling or storage, excluding typical office or household waste? 9 Any grading or ground disturbance during construction? 10 Any new storm drains, or alteration to existing storm drains? Yes V X No > y y 0 y > ^ & > *To find out if your project is required to obtain an individual General NPDES Permit for Storm Water Discharges Associated with Industrial Activities, visit the State Water Resources Control Board web site at, www swrcb ca gov/stormwtr/mdustrial html Section 2 Construction Storm Water BMP Requirements If the answer to question 1 of Part C is answered "Yes," your project is subject to Section IV, "Construction Storm Water BMP Performance Standards," and must prepare a Storm Water Pollution Prevention Plan (SWPPP) If the answer to question 1 is "No," but the answer to any of the remaining questions is "Yes," your project is subject to Section IV, "Construction Storm Water BMP Performance Standards," and must prepare a Water Pollution Control Plan (WPCP) If every question in Part C is answered "No," your project is exempt from any construction storm water BMP requirements If any of the answers to the questions in Part C are "Yes," complete the construction site pnontization in Part D, below Part C Determine Construction Phase Storm Water Requirements Would the project meet any of these criteria during construction7 1 Is the project subject to California's statewide General NPDES Permit for Storm Water Discharges Associated With Construction Activities? 2 Does the project propose grading or soil disturbance? 3 Would storm water or urban runoff have the potential to contact any portion of the construction area, including washing and staging areas? 4 Would the project use any construction materials that could negatively affect water quality if discharged from the site (such as, paints, solvents, concrete, and stucco)? Yes >< )< No f X -^y Part D Determine Construction Site Priority In accordance with the Municipal Permit, each construction site with construction storm water BMP requirements must be designated with a priority high, medium or low This pnontization must be completed with this form, noted on the plans, and included in the SWPPP or WPCP Indicate the project's priority in one of the check boxes using the criteria below, and existing and surrounding conditions of the project, the type of activities necessary to complete the construction and any other extenuating circumstances that may pose a threat to water quality The City reserves the right to adjust the priority of the projects both before and during construction [Note The construction priority does NOT change construction BMP requirements that apply to projects, all construction BMP requirements must be identified on a case-by-case basis The construction priority does affect the frequency of inspections that will be conducted by City staff See Section IV 1 for more details on construction BMP requirements ] | \A) High Priority 1) Projects where the site is 50 acres or more and grading will occur during the rainy season 2) Projects 1 acre or more 3) Projects 1 acre or more within or directly adjacent to or discharging directly to a coastal lagoon or other receiving water within an environmentally sensitive area 4) Projects, active or inactive, adjacent or tributary to sensitive water bodies | | B) Medium Priority 5) Capital Improvement Projects where grading occurs, however a Storm Water Pollution Prevention Plan (SWPPP).is not required under the State .General Construction Permit (i e , water and sewer replacement projects, intersection and street re-alignments, widening, comfort stations, etc ) 6) Permit projects in the public right-of-way where grading occurs, such as installation of sidewalk, substantial retaining walls, curb and gutter for an entire street frontage, etc , however SWPPPs are not required 7) Permit projects on private property where grading permits are required, however, Notice Of Intents (NOIs) and SWPPPs are not required ) Low Priority 8) Capital Projects where minimal to no grading occurs, such as signal light and loop installations, street light installations, etc 9) Permit projects in the public right-of-way where minimal to no grading occurs, such as pedestrian ramps, driveway additions, small retaining walls, etc 10) Permit projects on private property where grading permits are not required, such as small retaining walls, single-family homes, small tenant improvements, etc fOwner/Agent/Engineer Name (Please Print)/ yuwnei/Myi v •>Xx? r\ft Title Date //- f 1 6 City of Carlsbad Plumbing - Electrical - Mechanical Worksheet Project Address £ IQQ C Perm.t No G&mfl^ ) Information provided below refers to work being done on the above mentioned permit only This form must be completed and returned to the Building Department before the permit can be issued. Building Dept Fax (760) 6O2-8558 Number of new or relocated fixtures, traps, or floor drains New building sewer line7 Number of new roof drams7 Install/alter water line7 V ^ Number of new water heaters7 Number of new, relocated or replaced gas outlets7 Number of new hose bibs7 ,/TO — Ves_ O No Upgrade existing panel7 From Ves_ _Amps to_ No _Amps Number of new panels or subpanels7 Single Phase i &-«? Aw^& Number of new amperes Three Phase Number of new amperes Three Phase 48O Number of new amperes Remodel (relocate existing outlets/switches or add outlets/switches)7 Ves No Number of new furnaces, A/C, or heat pumps7 New or relocated duct work7 Number of new fireplaces7 Number of new exhaust fans7 A 0 Relocate/install vent7 ^ ^^ Number of new exhaust hoods7 l/\f* Number of new boilers or compressors7 V\ Ves No Number of HP ^•& £ S (Ti 3oi i mm 0 ID O xrn K>m co »« . °o ' (S) £Tl