Loading...
HomeMy WebLinkAbout2195 FARADAY AVE; BLDG D; 85-467 D; PermitIll z 0 .: <( ac <( -' (.) w 0 1 ___,.., ac I[ 0 (.) ac w 0 ... 5 Ill ii: w z 3 0 z 0 j:: <( Ill z w a. :::E 0 (.) Ill a: w :.:: a: 0 3:: ~I hereby affirm that Isam licensed under j ~lslons of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full for!le ~,effecl,'-/ n_ J Lie No "2-7 (. Class I',,;} , I hereby alfirm that I am exempt from the Contrac- tor's License Law tor the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which re- quires a Permit to construct, alter, improve, demolish, or repair any structure, prior toils issuance also requires the ap- plicant for such permit to file a signed statement that he Is licensed pursuant to the prbv1s1ons of the Contractor's License Law (Chapter g commencing with Section 7000 of D1v1s1dn 3 of the Business and Professions Code) or that 1s ex- empt therelrom and the.basis for the alleged exemption. Any v,olalion of Section 7031.5 by an applicant lor a permil sub· Iects the applicant to a civil penalty.of not more than five hun- _dred dollars ($500). 0 I, as owner ol the property, or my employees with wages as their sole compensatmn, will do the work, and the slluc- ture IS not intended or oflered for sale (Sec. 7044, Business and Proless,ons Code· The Contractor's License Law does not apply to an owner ol property who, builds or improves thereon and who does such work himself or through h,s own employees, provided that such improvements are not intend· ed or oflered for sale. If, however, the building or improve-ment is sold within one year of complet1on, the owner-builder will have the burden ol proving that he did not build or im· prove lor the purpose ol sale) .• 0 I, as owner ol the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code· The Contractor's License Law does not apply to an owner of.property who bmlds or im-proves thereon, and who contracts for each projects with a fg~f~ctor(s) license pursuant to the Contractor's -License 0 As a homeowner I am improving my home, and the follow- ing conditions exist. 1. The work is being performed prior to sale. 2. 1 have lived in my home for twelve months prior to completion of this work. / I have not claimed this exemption dpnng the last three years. 0 I am exempt under Sec. _______ 1,, B & P.C. lor this reason __________ -I-·--- tJ. ' hereby affirm that I have a certif1ca~f ~sure. or a _pert1ficate of Workers· c..dmP surance, or a certified copy thereof (Sec. POLICY NO. COi,1PANY ~Copy is filed with the city D Certified copy is her.-by furnished CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) or less) D I certify that in the performance of the work for which this permit 1s issued, I shall not employ any person in any manner so as to become subject to the Workers· Compen- sation Laws of California. NOTICE TO APPLICANT: If, after making this Certificate of Exemption, you should become subjecHo the Workers· Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. 1[ D I hereby affirm that there Js a construction lending agency for the performance of the work for Which this per- mit is issued (Sec. 3097, Civil Code} Lender's Name ____________ _ Lender's Address ____________ _ CARLSBAD BUILDING DEPARTMENT APPLICATIO,t & PERMIT I Carlsbad, California 92008-1989 (619) 438-5525 l ,· JOB ADOR'ESS AV.ST.RD. NEAREST CROSS ST. 1 D~ r~tr~~ION' BUSl],S LICENSE# (/_ v;it:~~~ PERMIT NUMBER --2-f q..:r-•· . ~ ~ ... :3:>A-....J -~ _,µ..-1.--:D I_ ., -• • ~ j LOT BL¢"K _, 'sUBDIVISION I AS~SSOR PARCEL NO. CONTRACTOR ' ., CONTRACTORS PHONE # ZOl"lE ·, /Col-(. C-oN'.r :r C,,;;).., G. c:; '2.--:-JJ"J1 ~ OWNER'S NAME C-7){_1 7-a,~::.; P;O~E C/4,UftJU fitJ'~ CONTRACTOR'S ADDRESS LICENSE NO. PLAN I.D. # BUILDING SQ. FOOTAGE 73:So 6/f.l?/N,'F:K 4 2,'2,,l -71:. '-/ OWNER'S MAILING ADDRESS ~ 0\tc'.J-0 a_,~q&.\\ \ 7:330 /4-Vt-t.tV£~rt,. J ·;,,_,,'jl DESIGNER DESlGNER"S PHONE C:.0Mt..v'£.L (. /M~ll--9-lt.. , -Z.93-7'17 ' DESCRIPTION OF WOR~ I .,__,G,;.. ~ Jw..<Ul\ DESIGNER'S ADDRESS SA\\. a~~ 1 ~_'!d\Q ~LICENSE NO. I ~-~, 1.r~~· ;e·.-~-31 ' 0 ~ / ,,V~ {!1~1 '-. lt.-lO I . I ' F/P FLR ELEV. NO O~GP EDU 4:l067f366B6f '1'7!3134;34 I ~ I l -I 1 -/ : / -;---IJ ,J::\ ~.A~ A) '4l...r..L:-..b STO,IES . 1.,,,-,,,i ., I, YO NO I CENSUS TRACT GP LAND USE I PAR1JNG ~PACE \.tES UNITS I GRADING PERMIT ISSUED I REDEVELOPMENT v(J;j.} OCC LOAD Fl RE SPR I AREA ~NO f YO ND YO NO Not Valid Unless Machine Certified I '1~ 3::-I QTY. PLUMBING PERMIT· ISSUE QTY. MECHANICAL PERMIT· ISSUE SUMMARY/ACCOUNT NUMBER : "Z-""t ·-r"EACH FIXTURE TRAP I,._,,::,: -If/. INSTALL FUHN. o·ucTS UP TO 100,000 BTU /""v.-BUILDING PERMIT 001-810-00-00-8220 /"';;)/.~ - I I EACH BUILDING SEWER '-~r;i .... OVER 100,000 BTU SIGN PERMIT 001-810-00-00-8221 l -EACH WATER HEATER ANO/OR VENT BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 001-810-00·00-8806 qr.{4--::;:-i --I -EACH GAS SYSTEM 1 TO 4 OUTLETS --:"" 801LER/COMPRESSOR 3-15 HP TOTAL PLUMBING OOH 10-00-00·8222 ., '""-I - I EACH GAS SYSTEM 5 OR MORE METAL FIREPLACE ELECTRICAL 001-810-00·00-8223 .J'"o..r-I 1 EACH INSTA~ .. ALTER, REPAIR WATER PIPE !I VENT FAN SINGLE DUCT '"2..~ -MECHANICAL 001'810-00-00·8224 4i----I EACH VACUUM BREAKER MECH EXHAUST -HOOD/DUCTS MOBILEHOME 001-81 O·OO·O_D·8225 I I WATER SOFTNER RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK INSP r EACH ROOF DRAIN (INSIDE) I ~ SOLAR 001-810·00-00-8226 . I TOTliL MECHANICAL -~v STRONG MOTION I , -· q7.-880-519-92-33 ..,_-.1.";;///flP f TOTAL PLUMBING I f.d:1--i .... ~~ , FIRE SPRINK~ERS 001-810-00·00-8227 ·l. ~ I £fl~~lu~ •tlo~ PUBLIC FACILITIES FEE 332-810-00·00·8930 G,fJ1,,"1 -I QTY. ELECTRICAL PERMIT· ISSUE QTY. . . f -f NEW CONST EA AMP/SWT1BKR .J lt)i -COLLECTORS-,.. (' "0 ie.0~':-a,.\\C-,· SCHOOL FEE • DISTRICT 1 FPI-J vm-STORAGE TANKS \)'v-"· ..... ~<tJ..w--..... ~~ ~ Carlsbad I 1 PH l EXIST BLDG EA AMP/SWT/BKlr ROCK STORAGE nl\ ~ :..C\t~').., Encinitas I 1 PH 3 PH PUMP .... ,Att.1 --.,,,\'\ ~ , .. San Dieguito I f REMOOEL.'ALTER PER CIRCUIT PLAN CHECK FEE --:.~ (\~~,._. San Marcos f TEMP POLE 200 AMPS ~~'\\""" I LICENSE; TAX 001-810-00·00·8162 -f OVER 200 AMPS I TEMP OCCUPANCY !30 DAYSI-MFF fn ,lQ 880·519-92-57 .J '-71411? -I CREDIT D~POSIT £ ll-.t'/.'?:>-~ 1 I TOTAL ELECTRICAL I ..Jo.C -TOTAL SOLAR TOTAL FEES PAYABLE I Jiqx'4-,~-I i f I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Expiration. Every permit issued by the Building Official under the provisions ofth1s * AN OSHA PERMIT IS REQUIRED FOR fxCAVAT'tlNS OVER f CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by limitation and become null and void If the building or work 5' O" DEEP AND DEMOLIT'IJN OR CONSTRUCTION OF f DECLARA1'I0NS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS authorized by such petmit 1s not commenced wilhin 180 days !tom the date of such STRUCTURES OVER 3 STORIES IN HEIGHT permit. or if the buildinff or work authonzed by such permit is suspended or 1 ISSUED: TO COMPLY WITH ALL CITY. COUNlY AND STATE LAWS GOVERNING BUILDING CON-abandoned -at anv time a ter the work Is commenced for a oeriod of 180 davs. . . I STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND , • CONTRACTOR.),' APPRO'XD BY 911/t /4 KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS,,COSTS ANO ~N"TURE ~OWNER 0 I EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ~ _ BY PHONE 0 • -. ..a ........ ~ .. ,::;,;. I r GRANTING OF THIS PERMIT. . ._ • z;.l>'-> ·.-~.,-·. -_-., 1-r I <:~~ f --. r: ', .. :·· _... r" ._.r., -... ,, • ,-,,'•, ::·; ... ~:-~-, ,• ,•a,·,-.. ' :··~·-~ : ·\·:. 0,··;''r.·:. ,.. (·.\,,, ..... · · .... 'If.· .: ... ·. , ......... ,. ·· : • • -1'<' · ·· -:~~·,{.J(o7,·Q '~.:. : ;::.r:_;,"'1y, . ~ -.. '. ,_r ,,t.<4.: ,{!~r·< , .........,. ~,~ /r,2:-'~ .. -r(: . ri,i-: -·--1.~--- j<' .·-' S:uii~iNG'' t ' p~TE~ if<,PE°',)11 ( ' ,'' .c :r ' . ... ,,• :s, \,. >> ' T :\ / .. i. ., :·FoHN0At10N·-' < . -i ,·;, · ·} -.·-· t· ... F,E1o'.iNsPEc:r,oN Rfac9a0·-_ , · . , , .. r '. "· tl$1~fo)'ic!ip $<t,iic: ' Lf ' ' ·. ' ' {. ,. . ' : : ~,60,a~;;:,;; ,C,~~. '~$pscf1 o~s.:: ' ,. i '. • .' ' ·~eicf o,l's Notes . ···., ' \ \ / ') "/ ,+-\ l:'" M.A~N.RY' ... c -· ._L._. ··'-· '., -"•, ·-~ .... ·BEG:IF. IN_SPE.C:i'ORS ',' ·, ·,, ..... ·,, .,, ... ,,, •,, .... \ f ' ·, ,,, ............. ·:·-·_, .. _ .... · · ....... -,. ·.· 1 · INSPECTION ·. ·,· . · · 'A'p·rp o11· · · DATE ·., · --,.,. ,. , · ·, .•· ~UNITE ·QR· GRQUT ' ' ' ' ... · CHECKED R · vcAL· ' · • ' ·, ..... -~---1 • , ,,,. .'\.:!· ..... ·•· ,: :,' .... ·· ·•··· .. :, __ ,.,_,. ..·.,. .. . ';, ···.:·· .. ·,.,. ... -' ... ., .. ""·,· ·;,,-·-·.,.:;·,;--... · ·,,,, \ L . $~,8-. ~RA,~~ ltl .f~~Ofr D CEll!l~'G · ·-: .,,. 89,~_s cqMPLIANC~ · I' · ..... · • .. :· i '-\. :_;:'_ · -·~ -· · ~-:.}~ )j'.·:::·:· ·· t -SHEATHING .EJRQOF D.Sli[EAR _,.______ Pfl.!_@BTQ . .... .'.°"-' ·_, t .·;·.··.:,:.'.' ' ··.:·: ... ···r·"'" -FOUNQATIONlNSP 1;· · . ,FRAME. ., -· .. -· ·-~ -· .: ;· ... ·; ... : ·,, -· .: .. · .. :-. · ..... •. .·,-· · --· 'STRUCT(;JRAL ~ONCBEJE ¼. ~ :E;~l11;R.,!9_R: LA TH -J: . ,., . . . OVEF.! 209Q' f:'S1 .. l .. , ... , ,;•,:",'""' ·· .,._.. ·'I·. 'PRESTRESSED ,_. -. .IN~.tJJ:_ATI.ON. . . .. . . .l GONtRFtE ,• ' ., .. '! ' 1 -, • ·' ' • • • --• • ' '•'' • "' ' -• • ~ I --:.; -. -·.: , . . ,,.t , , 4, - ·r 0"', .. . ,_ .. ~,.,.-. -· 'J.J--*·· n· ·:1 :~;·,-,, ,., .... 1 : , -, INT.~HIQWLAJ:HJt.PRY:VVAL,l., , L'":. ,· .. ,. . . post TE/>l.;:iorsiEp . : .i• y '/.:} \-,··:.:,;,, .:,\":··;·,•. ·-·,.',',' .'.:,./J\:;' ··-···· .\,:~:' . :;/,11\JCl:fi:;.r'(.7•?~~:•,',':.,_·::·,,r_:} .. ,, f .. · · -~, . . · . ·. piJJNIBIN'G · ,r. -. . _ .. , . .. ·, · "\ "~:</~ _F,1ELD wEtiirkii:3 · · l· l,--· ..... , .. ----- '':·: , "D. ~$6W.~(3_ AKH).._ BJ-JCO _,;: []. p~~()q. . I·, _:-.: :..~+>-· . :',I·· HIGlf.! ·;,T.8E;J\J,QTH . .. ,· ' '·. '\..: 1 · : .,· ' . L. ' ' . ,. I ,.,.. : ;:} .... ·-.~<i;: -~:\:;_, ·, .. /. ,,. -. ..·. ' ';._ 1,.,,i '-,,.:,._ J -\)NP~RGRQQ_ND.:·._-.tJ, W.A~TE QJWAt!=R ,. . .. . ..... ~, .... . '' ,, .. . . ' -\ ' ·;_,: .· rop_pyJ,-·_. P:WASTE: .:•: .-P.WAJ"~R "I , , , -, "' -, --, ., ~-..... ----, · ~ , I , ,·····-;~ --!3~-L T$ ,-. ·"' ~ ! =:::,. ~-:··· :;;;; --i.>, .. ,, ·- . S~E~!AL fl(lA~~NF-t:(. _}jj 't'.'\ '· . '·-'· . -. ·~ . , . , • ,i ,.t 'irl ,:_f l , ..... , .• . -~ ;.-, -~ ~-.; ·--~I.\·_:_~ ....... :-,_.;. ~ .---~'., -:\s1~¾,~1 ""'t;."\-~- -~·-~:-.. ; -~ ~ ~-~·::~_:{\\~ } . . · TU 13, ·A-~ 0 S,H.QVI/E_~;PA~· , . . · l- 'l. . ,GAS TEST .. ·. ·" ·. · · '.: .·; Lli t • -, ' ,,',_,·., •• ,. ' '",':,./:.::,.:: .. ,.., ,:1--~(::/ · .. ,, ",, .. ' ,: ,, .. ,,"'_ ·,:"F---·_-.,.--.-,. f. · El Wlf'f~R:-1-'tEAt~R :Cl.~QJ:;A@W~Ti~R , ,.'(. PI.LE-S,.C,!1,1.SSbN·S J.' t ,,.,·., ,,., .. , ".. "• ,.,. ~·-,. .. .I,'.'. ·,", .I 'ft; ( J, ... .·.. ·;:>..., .'., .. ..... . .. ... -{ \ r . s -.... ~ ""·--: ., __ ~·-·· ~ ', l t b ft.. f r. ... l ~:._,I -..I, .s kt~' ~ i1·· ff\ . >,.'r.j, ·t' .· l," 'i ,; v~'~ '. ,·, } . Et:ECTRICA(:· > ,1:-p -,~ ..( ' ·l 0:; :tt E:f.E9T.R .. l?_q~~,ERG~OUNp· -; · · HO~Gli ELECTRIC oJ i:J f FgR . I~., 1 . . . 1 ----~ --1 ,; I r · --" --1 · 1 . , . --:c~._--... : :·. ·r I -. ·--- .. ,, '·i -I· .. , , ··:I-, D ELECTRIC SERVICE D TEMPC>R~RY . --·. ~''-----'-~-_'_~ _ _'. __ .-__~-----· -~, -'.·"-• '; ,~ • , l -~ 1,, I' ;;-_v.~._, __ , _ • ';.'"·~: ;·1 r ,·f.,• ... -:~>·;.~ ... ,.. \ \-·}-' f., . -·.· t ·: . .. > . ,J. \ .~ • r:< , . . : I o:,aQNP.fN:G.t.'_·ttl P,0¢1;· ~lj, I,' i < ' .,,, ~"-_ .... ""<i~~ '~ '.!. .... ·.c. ..• _': _\(~. M.ECHANICAL -· :-'1 .. ·.. . . ,.· .--:~, ·:·. . · -~ I · · ;p i:>uQt ~, P,~Er~f.(_, __ . E;J :R1;F·:_t:,fPIN,G -~~._,; ~,~.~-, :, :;;:__:,; _ ~,: i.L..:.;, ·:. _~;.) .. '. :::~-. :.-., >: ,~!-' ·· -. ,1-, .,. .1 . -HEAT :....:: AIR·CbND: ·s¥STEM$.. .,, ,.-:;:" ;---..;..'....i ,~ -......:.; -·' ~ -,i:.,.1 . ...:...:> -~ .,. ·. · 1~·--:3 :,:.,\ t 7 • .·.:;.. r ,.-.,· • , ... _ : '', ; . -~> ~-: .. ': ' · . . ,;-\ :·,, ~7-';) • .; .. -r-·, i:.:.:f ,. i ~--:~ :.· . . <y-:,. . ..... . ·, ,:/.-1'. • : . <, -VENT.l!-A:J:ING-.&:YSTEMS. , :·' . ..,.: .. :1_ -~--~-:< ,, . .1,,-. .. ,:,:: •. t .... , { .. '> • ...,,,s_-£·0-· .. · 'i'. ,,, , •.. ,_, . . -, ., . : .· . ,. -. ,. . . , ., .. -· , . .-: . , . ! :"";_,/::<:;:.: .t~t) ~"'"··-. :·:i,~¥,t~:tt-i: ff . , .. , ' .. ; . · ·::· ~: · ... : ,-r, ;t//'..'~Y P!·;r,H~ f~. . :~AL.L.,.FOR.:FINAL INSPEGTiON_: WHEN AiLAPF!BOPfUlfPE ,.--"".''. -. . ' .. ,··· ,' _:·, I '' ·,.~'.~ .• :, .. --=:.: -. :.~ : .. l .. ,:, '' .. ,:~-----L-, ..... .-·~ '-1.·: ...... -\ -·. i ,,------"-----~~;_,'t. • -~- · . ·: · ITEMS:ABOVE HA E BEEN, A'PPRQVE'f)~'. :", .. -~ :·_ :-,:,· ;.: '.' ·• · · · ·· , . 11 -., ·· · , , ···, ' --' -• ~ ·-• ~-~ --' ' -'! ... ( ... ' f, I ·FINAL .··1 .. -~,;'·1·1-··-:r._,..r,_,:L· .-.,, ·PL1Jfv1BING ._... _,, ~ I . '.::-,. ·-·Et.ECTRICAL .. ,.. . 1 .,~_. -1 ::-1 ... ~ ';"·· I :·'. . . ' ..... .,,_ -.. ~---. / --·,··~' . ", .,1 '..--=-~·:.: }\ r., ... !,-·--~ t'.' ,, ..... ~: • .(-. 1·::- ,L___ __ .'._·c:__._."'----=- •,,.1;'. .,. ~ . ~-'\ -~--C" .. ,;: · . ~-) .l ' .,., ~ ~-;~~ •. c,-"-; ,.. ~~:) • :/:; ·· : ·-. ,\ '<~: ,_"t, ';..: ~~ ' -)/ -~; 1' :··\ ....: .. I i . ·1 ,,, ·, ~ .c_',-A"\.it.l.'. I~~;~--1~· ~ ..... ';"~1,..:-~-?:.;.><,~ ..... .-._,~·.\, ~t·.:-t{· ~"- { ~~4 '\. \~~-':~ '/; ·~ -<t 1 ., ','·· . ~ ~ ... _. .. , -~.q. ·,, t,'... . M~CHA·t,ftCAL><:=: l .-:,:.'. .. ' -~--I ,' rlq ~ : :I.· _, · ~ ,.c · · I ' ·,;' " . ---~ ~/ \' .J~~~rNI(: r... >< }: r·' . l 1 I I 1 \ • ~ ~.. ' .. • • ' • -I '•'' ,.,.. l ' _,... ..... ~-;,-.-:l>,.~~-•• ,, ' .. . • . ' . .. . :-: d u • -'' .. --· • ' . ·" '.. <J ,· :.".'. ,:·· ' ,, . ,.,-·:. ·. -~: ~'I/\ :_:: . R.' ~: . ::'·\ ~.>\'''. _..;~; ,. ,"'.;-;_ . __:,, '}:f:::''(. ~.--f,•c .\ ' ... -'5PEG.IAJ:, CC;}NDIJIONS. ~:' " -~ ~-~' ' ._. ~~,: "l/:r·., ... · '·'.t~- ,:,--"--.. · --.:: ·:. ,:.i .. -' ~ ... _ .... ,,. '.''" .. ·1 .,_--.··--.: -·:,-·'', ..... ··::~_: __ ~._· ... · \ .. _·=.\_·''.._,' -----.----,~-.-· ··-· I ,l J, .r . _-.:/---r \• ··.:I ... ,i ··--'I :: SEE 2185 FARADAY AVE FOR MORE INFO ON 85-467 • J ;.., -"' . ' .. APPLICATION FOR P-ERMIT TO CONNECT TO CITY SEWER SYSTEM. CITY OF CARLSBAD \\1 ·-' SE "'-z·1 7 ENG l,N EE RING DEPARTMENT r! t .... 438-5541 / (,' _,.,,·· I , . I ISSUED BY ~+ ... ( ,• ~ ,:?,· "' ' ' ,., • l ,, ,.. FOR APPLICANT TO FILL IN ~ -'('• ~--:i DATE ISSUED . BUILDING ADDRESS ] } ~-r; r .·/.,: . .t_ •• ~ ..t} .,. .. ;;fc,•'.i VALIDATION OWNER ( 'j:-.,_ \t \. '-.,'-:1\ \ \ ·J v~N f' -f{,\-\ (1\1 t:""\\.\\ \l : ; "Q ' -(7. ;::" V ;~ h' \ ~-lt \HI .). l ,f!:,.\) MAILING . -l\\\ \"\ \ \1(,i. _(· I~-C\ ~ \\ \ ADDRESS '• . -LATERAL CHARGE COMPUTATION CONTRACTOR '' .\ 'f.-. '\. L { '! 1 t,..\ 'S-.. \'/ t\\:'\ ,I 1\--\ (,L. STANDARD 4" (Max. H • 30', v. 10') .. ., OVER 30' H. @ FT. -f--':/":\1 v t-. ~ { ~ 1 =· rn \ 11 I • OVER 10' V. @ CONTRACTOR'S ·' 't'C1 I\.\ J FT. ADDRESS C .. Ls:.\ -\ h \tt'•I, ) (. i~, t't :;\_\ l \ STANDARD 6" (Max. H. 30', V. 10') '. I @ OVER 30' H. FT. NEW BUILDING ' .. I EXISTING BUILDING I OVER 10' V. @ FT. 1', LEGAL DESCRIPTION TOTAL CONSTRUCTION COST ~ ,JI ; i -. I,-·, ll ,-SERVICE CHARGE (REPAVING ETC.) I ,, ' l"' / -TOTAL LATERAL CHARGE ·, :~ I. ~:f .. ' .. ¥ ~ ,-'t" ,: j , REMARKS: }9 <. LINE COST DATA I ,. 1 .. . ' /_ I'-• '"I:. {' '' ' . . I/.",.-It ....., ,·: : .~·,_ 3{1 ASSESSMENT DIST. NO. . ' -' , • ,.._I -,,, '/., . " -,,11-1 ";..f ~ ,\ r .. ,. " ' -: ,., • •t,. ··1 ,, ',, FRONTAGE COST PER FT. TOTAL v•;" ----, .. OTHER .1. 7:~:: LATERAL LOCATION CONNECTION FEE i.-: I I i.-: Cl) Cl) _.., .,,,~ COST PER UNIT fa·· .. ·,,. TOTAL<:_ ·,;:-,,. NO. UNITS~ , ,.;,• ,,.. "\ /' I"\ PUMP STATION FEES \,. ,/ '-../ NO. UNITS COST PER UNIT TOTAL I I ST. .i,. TOTAL CHARGES (LATERAL ETC.) '~-;.. ~! ;;.., '1_-~-.,-1: '- LATERAL NO. INSTALLATION DATE WHITE: Engineering GRE!i:N: Fin,ince YELLOW: Sanitation PINK: Building GOLDENROD: Permltter THIS IS •ro CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE CURRENT ENERGY REGULATIONS, CALIFORNIA ADMINISTRATIVE CODE, TITI..E 25, STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT: SITE ADDRESS: _8\...-04=:t D Number Street c.~\2,t..;)8, AD (? I q5 -FAAA~Y) City EXTERIOR WALLS \ i ./1 "2 l/'. I( J J Manufacturer_,_'-'_, ____ \ ___ Thickness/Type --..J a R/Value __ _ CEILINGS -LP\l..,\OJJ Batts: Manufacture::: ~\--\ Thickness (or~uR/Value IC/ -------------- GENERAL CON'IF.ACTOR: LIC.# ----------------- BY __________ TITI..E _____ DATE ______ _ INSULATIMONTRACTOR: WESTERN INSULATION LIC.# 481278 B~-~ TITLE~p~~!;/lli\TE )N,l t.:.\ \&o ,· .,, I FINAL BUILDING INSPECTION /I 85-467-D 1:1.-6-86 PLAN CHECK NUMBER: DATE: ' PROJECT NAME: ADDRESS: 2195 Faradnv PROJECT NO.: UNIT NUMBER: TYPE OF UNIT: Co~erci,:ll NUMBER OF UNITS: CONTACT PERSON· Scottie CONTACT TELEPHONE: H,."'GLX 931-9108. all ch-mt INSPECTED DATE ~ z)7b / BY: INSPECTED:~ ,/2 -APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED I , COMMENTS:-------------------------------- Rev. 1/86 WHITE: Suspense . GREEN: En_gineering CANARY: Utilities PINK: Planning GOLD: Fire ~, ~-- '" .. ' ~ . _:: FINAL BUILDING INSPECTION ;I RECEIV NOV 1 0 -~2J6 , PLAN CHECK NUMBER: ADDRESS: PROJECT NO.: TYPE OF UNIT: c,,1'1"-~0rci::tl NUMBER OF UNITS: CONTACT PERSON~· --~S~c~o~t~t=i=,~~·-------------------------- CONTACT TELEPHONE: r'.IJ3tt{ ~31••030$ INSPECTED~ BY: ---"~"+"--JF-"-'---'c,..._--- INSPECTED BY: _________ _ INSPECTED BY: _________ _ DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: Id -lj -£ APPROVED v:::: DISAPPROVED __ _ APPROVED DISAPPROVED __ _ APPROVED DISAPPROVED __ _ COMMENTS:---------------------------------- Rev. 1/86 WHITE: Suspense GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire . ., •,f. ; t, FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: 1:1.-6-,16 PROJECT NAME: ~-------------------------------- ADDRESS: _____ ___:•.:....! l__.,~)~· ~-j ...::F:..;::;.J...:::t'=:1'-"d'-'-n__.,_v _______________________ _ PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: CONTACT PERSON:, __ __,_f=;i·,_,,,:1'-'-t'--'-'tc..c'l.'"'"'r-:'--------------------------- CONTACT TELEPHONE: mt,r•: ~ru-~i:ios INSPECTED BY: . DATE 11/t,/Jtl DISAPPROVED L_ INSPECTED: APPROVED DATE /-'j-Y-1 APPROV~D C>(_ INSPECTED: DISAPPROVED INSPECTED DATE BY: _________ _ INSPECTED: APPROVED DISAPPROVED •• COMMENTS: -~=¼'-----./k-=-~~~'-------1---· ,_ _____________ _ ·,\ • Rev. 1/86 WHITE: Suspense GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire { · FINAL BUILDING INSPECTION .. .;.. ·, ,._ ... ~PLAN CHECK NUMBER: 85-467-D DATE: 11-6-86 • PROJECT NAME: --------------------------------- ADDRESS: Z195 Fe.:rad.qv PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: Co;.-:,:m,::n:c:!.al NUMBER OF UNITS: CONTACTPERSON·~ _ ___,f=,c=.O~t~:t=.1~~~------------------------- CONTACT TELEPHONE: ffllxX 931 -9308 all d0.nt ~Ny~PECTE~~ ~~TiECTED: # APPROVED DISAPPROVED INSPECTED DATE ·BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS:l------------------~--------------- '\ Rev. 1/86 WHITE: Suspense GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire I \ . ' .I ~ \ American Engineering Laboratories, Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date ______ __,9;;;,</,.,;1;.,;5.._/~8-=-6==..,.,,.,,,, Project No. ____ P_-""'5 __ 4 ___ 8 _________ Report No AEL 6-Hl84 Client KOLL CONSTRUCTION COMPANY ClientAddress 7330 Engineer Road San Diego, CA 92111-1464 Project Name (per plans)_.,,.:::;.:,;~,:.:.:::~-=-,,:.-2---:,,.:.::..==:....;-=-,-=-..,.....-,----,,~--,..,,..,,-:f=.,,.,.=- Project Address (legal) \-_,;;~..;:;...-=-=~~"'-:-..:..:.:~+~;..;...;~F;;..a...-=-~,,_...=..;;;;..;,i.;:;.....;:..,_ __ Building Permit No. __ 8 ___ 5_-.... 4 ... 6 .... 7 ....... D ___ _ Plan File No. __________ _ Architect ____ _::::::::,~~~bb;~~~~WU~illf~~~=-fr--lr--:-- Engineer ____________ s_s_o_c_1_a_e...,s ________ ,....,,~~--.---'J'ract No. ________ _ Contractor _____ _..:..:.:;..;:..:......:C:..:o;.:.n:..:s:...;t:.:.r..:u:.::c:..:t:..:i:..::o;.:.n.:.....:C:..:o:.:;m~=~..,q.,AAr-c::....,..-4-Hf-1---=:,9-1, INSPECTION CODE _ Reinforced-eoncrete SIC Prestressed Concrete SIPC Reinforced Masonry SIM Struct. Steel Assembly 1. Shop Fabricatioo SISS-1 2. Field Welding SISS-2 3. H.S. Bolting SISS-3 Pile Driving , SIPD Nondestructive Testing 1. Shop 2. Field SINDT-1 SINDT·2 Fireproofing SIFP -X-Roofing IA __ Waterproofing IWP __ Asphalt Paving IAP __ Other ---~O MAT'L SAMPLING CODE Concrete Cylinders cc Rein!.: Rebar _______ _ _ Steel: _________ _ Mortar Samples MS Reinf.:W.W.F. _______ _ Metal Decking: ______ _ Grout Samples GS Reinf.:Tendons ______ _ Shear Connectors: ______ _ Fireproofing FP Cone.: Mix #/ps,_· ______ _ H.S. Bolts: ________ _ Units (block or brick) UB Cone.: Mix #/ps._· ______ _ Electrodes: ________ _ _ A.C. Concrete ACC __ Cone.: Mix #/ps._· ______ _ Electrodes: ________ _ _ Roofing RS __ Cone.: Mix #/ps._· ______ _ _ Cert. Welders: _______ _ _ Rein!. Steel RSS Grout: Mix #/ps·~------_ Fireproofing: _______ _ _ Steel ss Mortar: Type/psi ______ _ A.C. Concrete: _______ _ _ Tendon (PT Strands) TS Units: Block Other: _________ _ Other Units: Brick _______ _ Other: _________ _ Other Other Other CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need m::-re specific information regarding inspection procedures. INSPECTOR John Mauk INSPECTION DATE __ 8""'/-'1;;..a9.,_/..;;;.8..;c.6 _________ _ Special Inspection -Roofing (Bldg. D) Inspected application of cap sheet installation and mastic work of all penetration for completion of all roofing at this building. CC: 2-Koll Construction Company 1-Conwell-Marshall & Associates 1-Kahn Associates 1-Construction Surveillance Services 1-Carlsbad Research Center 1-City of Carlsbad ~!ECEIVED SEP 1 r;· 1986 CITY OF CARLSBAD Building Department 117 American Engineering Laboratories, Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date 8/1 5/86 Project No. _____ P_-_5_4_8 ______ Report No. ___ A_E_ L6_-_K_l_3_7 _ Client ___ _!,;K~O-=-L=-L ....!:C~O~N~ST.!..!R.!.!::U~C...!..T.:.:IO~N~CO:::.:.M.!!.P..:....:A.:..:.NY.:..._ ______________________ _ Client Address __ 7:....:3=.:3=.:0~E~n~g::1..1.:..:· n:.:;e=.e=.r:........;R:.:;o:;:.:a:::.:d:::__~,,.....,..-----------------------------San Diego, CA 92JJJ 1464 Project Name (per plans) --:::;::?~~=--==:=-~oc::::::::::::::::=---->--:~"-;-''--:"-"""7a...L..;::-':B;--l:....:d=·=---:D=---- Project Address (legal) -\.=;.::;i=---~~::----:..;...~~~"---=":--'-~-==:..i........;;C:..;.A-'--____ _ Building Permit No. _ ___..;;8;..;5_-_4;...;6;....7_-_D __ _ Plan File No. __________ _ Architect-------~~='-,!...!___:_:..:::.:...:::.:.~:....!...-=..:....:..:==.:;:..:.===----------Govt. Contract No. ________ _ Engineer _______ _.:...:..:::..:.:~.:..:.:::..::...:::...:::...~==-----------------Census Tract No. _________ _ Contractor _______ .:..:..;::...:....:--=:..;::.:..=-'~:.:::..=....:..;:c..:.:.._C.;;..o:::..;m.;.;.pi;;..a~n.,_y _________ _ Other _____________ _ INSPECTION CODE MAT'L SAMPLING CODE MATERIAL DESCRIPTION Reinforced Concrete SIC Concrete Cylinders cc Rein!.: Rebar Steel: Prestressed Concrete SIPC Mortar Samples MS Reinf.: W.W.F. Metal Decking: Reinforced Masonry SIM Grout Samples GS Reinf.: Tendons Shear Connectors: Struct. Steel Assembly Fireproofing FP Cone.: Mix #/psi H.S. Bolts: 1. Shop Fabrication SISS-1 Units (block or brick) UB Cone.: Mix # /ps; Electrodes: 2. Field Welding SISS-2 A.C. Concrete ACC Cone.: Mix #/psi Electrodes: 3. H.S. Bolting SISS-3 Roofing RS Cone.: Mix # /psi Cert. Welders: Pile Driving SIPO Reinf. Steel RSS Grout: Mix #/psi Fireproofing: Nondestructive Testing Steel ss Mortar: Type/psi A.C. Concrete: 1. Shop SINDT-1 Tendon {PT Strands) TS Units: Block Other: 2. Field SINOT-2 Other Units: Brick Other: Fireproofing SIFP Other _x_ Roofing IR Other Waterproofing IWP Other Asphalt Paving IAP Other IQ CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications ~ll.9 applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR John Mauk , INSPECTION DATE 8/14/86 Special Inspection -Roofing Roofing continuing according to specifications. 8/15/86 Special Investigation -Roofing Roofing continuing according to specifications. RECEIVED AUG 1 .-1~86 2-Client 1-Architect 1-Engineer 1-Lender -<; Iii. nJ-erry OF CARLSBAD v~ j"\ 'C (' r Building Department 1-City of Carlsbad American Engineering Laboratories, Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date 8/14/86 Project No. ____ P-_5_4_8 ________ Report No __ A_E_L_6_-_K_13_4 __ _ Client ___ __,iK~O:(..!;L:.!:,.L_:C~O:::.i.:N~S:..!...T~RU~C!...!.T-=-IO~N~C~OM~P:..:..A~N:..!...Y ______________________ _ Client Address __ 7!...;3~3~0~E::.:nc!.:g:L1!.!· n.1::e::.::e::.!.r---!.R~o~a:.:::d~------------------------------Sa n Qjeoo, GA 92JJJ-J464 Project Name (per plans) Building Permit No. _...:8::..a5::...4.:....:6a..:7c...-....:D=---- Project Address (legal) Plan File No. __________ _ Architect Govt. Contract No. ________ _ Engineer Kahn Census Tract No. _________ _ Contractor Koll Other _____________ _ INSPECTION CODE MA T'L SAM PU NG CODE MATERIAL DESCRIPTION Reinforced Concrete SIC Concrete Cylinders cc Rein!.: Rebar Steel: _________ _ Prestressell Concrete SIPC Mortar Samples MS Rein!.: W.W.F. Metal Decking: _______ _ Reinforce{! Masonry SIM Grout Samples GS Rein!.: Tendons Shear Connectors: ______ _ Struct. Steel Assembly Fireproofing FP Cone.: Mix # /psi H.S. Bolts: ________ _ 1. Shop Fabrication SISS-1 Units (block or brick) UB Cone.: Mix #/psi Electrodes: ________ _ 2. Field Welding SISS-2 AC. Concrete ACC Cone.: Mix # /psi Electrodes: ________ _ 3. H.S. Bolting SISS-3 Roofing RS Cone.: Mix #/psi Cert. Welders: _______ _ Pile Driving SIPD Rein!. Steel ASS Grout: Mix # /psi Fireproofing: -----'---- Nondestructive Testing Steel ss Mortar: Type/psi A.C. Concrete: _______ _ 1. Shop SINDT·1 Tendon (PT Strands) TS Units: Block Other: _________ _ 2. Field SINDT-2 Other Units: Brick Other: _________ _ Fireproofing SIFP Other L Roofing IR Other Waterproofing IWP Other Asphalt Paving IAP Other 10 CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you<!eed more specific information regarding inspection procedures. INSPECTOR John Mauk INSPECTION DATE 8/l 3/86 r. \fl l Special Inspection -Roofing , l\'b~ \ Roofing being done to specifications, with proper materia~~~,1(!0 4,'\[{', 2-Cl ient ~ 1-Architect 1-Engineer 1-Contractor 1-Carlsbad Research Center 1-City of Carlsbad Bldg. Dept. RECEIVED AUG lt 1286 CITY OF CARLSBAD Building Department 117 American Engineering Laboratories. Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date ________ 8_/_1_/_8_6 ______ Project No._P_-_5_4_8 ___________ Report NoAEL 6U-45 2/1 Client KOLL CONSTRUCTION COMPANY Client Address 7330 Engineer Road San Pieao. CA 92JJJ~J464 Project Name (per plans) Building Permit No . ..;;;#_8_5;...-_4'-'6'""7'""9"'--___ _ Project Address (legal) Plan File No. ___________ _ Architect --------?:£:!:!:!!:!:~~.!.2..!.~,l,g,,,bl::,~::f:!::~~.:,.::~::::!:...---------Govt. Contract No. ________ _ Engineer Kahn Census Tract No. _________ _ Contractor Ko 11 Other _____________ _ INSPECTION CODE MATL SAMPLING CODE MATERIAL DESCRIPTION Reinforced Concrete SIC ,-Concrete Cylinders cc Reinf.: Rebar --X-Steel: .A.36 -------Prestressed Concrete SIPC -Mortar Samples MS --Reinf.: W.W.F. --Metal Decking: Reinfortl!d Masonry SIM -Grout Samples GS --Reinf.: Tendons --Shear Connectors: T Struct. Steel Assembly Fireproofing FP Cone.: Mix # tpsi H.S. Bolts: ---------1. Shop Fabrication 5155-1 -Units (block or brick) us --Cone.: Mix # !psi -X-Electrodes: :z.orn V 2. Field Welding SISS-2 A.C. Concrete ACC --Cone.: Mix #!psi --Electrodes: --- 3. H.S. Bolting 5155-3 -Roofing RS --Cone.: Mix #!psi -X-Cert. Welders: : yes --Pile Driving SIPD -Reinf.Steel RSS --Grout: Mix # !psi --Fireproofing: --Nondestructive Testing --Steel ss --Mortar: Type/psi -A.C. Concrete: --1. Shop SINDT-1 --Tendon (PT Strands) TS --Units: Block -Other: --2. Field SINDT-2 --Other --Units: Bric" -Other: --Fireproofing SIFP --Other --- Roofing IR --Other -----------------Waterproofing IWP --Other __ Asphalt Paving IAP --Other 0 CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This repor;t covers the locations of the work inspected. Contact this office if you need niore specific information regarding inspection procedures. INSPECTOR INSPECTION DATE Jinnv L, Garcia (W-313) 7/23/86 Special Inspection -Field Welding Inspected the welding of pre-cast, tilt-up low wall panels of plate-to- plate conn~ction at panels W3 to W4 and ~4 to 19. 2-Client 1-Architect 1-Engineer 1-Lender 1-CRC 1-City of Carlsbad 117 .. American Engineering Laboratories. Inc. 7574 Trade Street. San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date ________ 7..:./...;.1..;;.5 __ / ___ 8_6.....,..,_-Project No.___;P_-...;5"-4...;8 ___________ Report No AEL 6U-418/5 Client KOLL CONSTRUCTION COMPANY Client Address 7330 Engineer Road San Diego, CA 92111 1464 BUILDING "E 11 Project Name (per plans) +:::..:~~~-;;:::-S~B~A~D:!.....!R~E:.:S~E::!:A~R~C~A!.....!::C:.:El!NT.!.'E~-.!.:.R-~~====-' S~,~~~:.:....:!:2:-_ Building Permit No. 85-467E Project Address (legal) _ _.,.-=--_s___,;--;F;--a~r~ad=a~~A-:;-v.,;;e-;;n.,;;u-;e;..:.,_.;;C;.;;a"":r:--l-:s;.;;b""'a .... d;....;, .... -_c_A_,--___ _ Plan File No. __________ _ Architect ______ _.!~~~!::!M~a:1;,.tr..:~s?.!h[!Ja~l.1..lw&L.!A~s~s~o;:c;;.1!.!· a;,;t;:.!e;.;s~=:::::::=------Govt. Contract No. ________ _ Engineer _______ ..:..K:.;:a:.:.h:.:.n:....:.A.;.:s:.::s:.::o=-c:::;..;..i a;:;..::;t.=ce.=cs _ __,, _____________ _ Census Tract No. _________ _ contractor ______ ...:K~o::..1.:..1.:.,_;C:::;o::.:n:.:.;s::.t.::.;_ru=-c=-t.::..:..i o=.n:..:.._C.::..o:=-:... ___________ _ Other _____________ _ INSPECTION CODE MAT'L SAMPLING CODE MATERIAL DESCRIPTION -Concrete Cylinders cc _x_ Rein!.: Rebar .8Sif:1 .86]5 _x_ Steel: ~ 36 --Reinforced Concrete SIC ---Prestressed Concrete SIPC -Mortar Samples MS --Reim.: W.W.F. --Metal Decking: --Reinforced Masonry SIM -Grout Samples GS -·-Rein!.: Jendons --Shear Connectors: _x_ Struct Steel Assembly -Fireproofing FP --Cone.: Mix #/psi --H.S. Bolts: --1. Shop Fabrication SISS-1 -Units (block or brick) UB --C-Onc.: Mix #/ps; _x_ Electrodes: :ZOJB _x 2. Field Welding SISS-2 -AC. Concrete ACC --Cone.: Mix #tps· _x._ Electrodes: 90J8 3. H.S. Bolting SISS-3 -Pioofa,g RS --Cone.: Mix #/psi _x._ Cert. Welders: YES --Pile Driving SIPD -Reim. Steel RSS --Grout: Mix #/psi --Fireproofing: --Nondestructive Testing -Steel ss --Mortar: Type/psi -AC. Concrete: --1. Shop SINDT·l -Tendon (PT Strands) TS --Units: Block -Other: --2. Field SINDT-2 -Other --Units: Brick -Other: --Fireproofing SIFP -Other --Pioofing IR -Other --Waterproofing IWP -Other --Asphalt Paving IAP --Other 0 CERTIFICATION OF COMPLIAN(:E: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR INSPECTION DATE Jinny Lyn Garcia 7/7/86 Special Inspection -Field Welding Inspected the completed welding of tilt-up in Building E at panels 11-12, 15-16. wa 11 panel, chord bar connections Inspected the completed welding of tilt-up wall panel, tie down-to-plate connections, 2 at panel 17, 2 at panel 20. Inspected the completed welding of plate connection at panel 22-23. tilt-up wall panel, corner ?~to- w~ \rv1 '\ff 117 7 /11 /86 Special Inspection -Field Welding Page 2 7/15/86 File# P-548 AEL 6U-418/5 Inspected the rewelding of pre-cast, tilt-up chord bar connection at wall panel 15-16 and plate connection at wall panel 14-15. Reset and plumbed for correct alignment. Inspected the welding of pre-cast, tilt-up wall panel, plate con- nection of panel 20-21, 22-23, chord bar connection at panel 21-22. 2-Client 1-Architect 1-Engineer 1-Lender 1-CRC 1-City of Carlsbad Bldg. Dept. American Engineering Laboratories, Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 ,. FILE NO. p...,54g SUMMARY OF COMPRESSION TEST RESULTS PAGE ___ _ Joe, / CRC MULTI 1.S, PHASE .IL ·· ,:./ tf;!::, -2-=J-8-§-Faraday Avenue AooREss, Carlsbad, CA THE KOLL COMPANY YEAR: 1986 •STORED & CURED, NOT TESTED CATE LAB. NO CAST t.CCAiiCN IN STRUCT,UR£ MO. DA. ' 1568 5/19 Building 4 slab-on-grade 20 1 south of north edge (center). 3 1625 5/23 Footing B.8 (5.5 to 7) and exit footing, C (6.25 to 7). 3 1664 5/27 Slab-on-grade line B.5-C ( 6 to 7). 2 ' 1665 5/27 Slab-on-grade line A to A.5 ( 5 to 6). 2 i666 5/28 Slab-on-grade line E to D ( 1 to 2). 3 1557 5/8 Footing at building D, line A • 2 ( 1 to 1. 4 ) . 3 - 1567 5/8 Footing at building D, 1 ine A (4.7 to 5.1). 3 1683 5/29 Slab-on-grade 1 i nes C to D (13 to 14). 3 27Koll Construction Company 1-Carlsbad Research Center, Attn: Charlie Abdi SPECIFIED 2Q MATERIAL, -'C~o_n ___ cr'-'e'-'t_e __ 2e-DAv STR., --=---0.a..;O.__~ Ps1 PROPORTIONS/MIX No.: 51-3164 Premixed Concrete Co. TYPE: ____ CEMENT: 5.2 Sk•SPEC. 5LUMP, ___ 4 ___ IN. Pozz. 322N 1 A0MIXTURE: _________ AGG. SIZE: ---.IN. ULTIMATE COMPRESSIVE STRENGTH. PSI SLUMP 7-DAY IN. 5.5 2830 6 2160 4 2300 4 2550 5.5 1730 4.5 5.5 5.5 1840 28-DAY 3730 3630 3150 3060. 3570 3820 3040 2900 4120 4030 4070 3080 3180 3220 n:sT AGE OTHER RJJ:S\JL."fS CATI: PAAILE:0 RE CEI VED ,IUN 27' 986 CITY I DFCA RLSBAD Bui ding De1 artment ·i( J • ~!, \ ~ ~UN 6 1986 IUN 2 0 1986 AMERICAN ENGINEERING LABORATORIES, INC. 1-Conwell-Marshall & Assoc., Attn: Harlan Tande J~1Q~ lLo~~ 1-Constructj6n Serveillance Services Attn: Jack Hanssel 1-Kahn Associates, Attn: Steve Mayoraga WILLIAM L. COCHRANE, R.C.E. #24445 1-City of Carlsbad 11•'/ American Engineering Laboratories. Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date ----.....;~~._,..,;;,-r,-:,.._...,..,.,,..,...,,.,,..,,.,.....,,..,. ___ .....:...P-_5.._4....,8,.__ _______ Report No, _ __._A....,E..,l _..,_6-__,K..._) .... 3..,.3.___ Client----~:;,.=.::~;;..;;,.;,.;..;;,.~:..;;..;..;;..;;.;.;.._;;_;;.;..;;.~.;...._----------------------------- Client Address -....!..::!.:=.~.!::.!.!.::I..!.!.!.!::.:.!.~~.!:!-----,------------------------------ Project Name (per plans) ....,.:..--::=.:..,.:::....:.:.;"'--=-.:...o..--"'"'---':......:.:"'"""'=---=------=....._...,._....,_,.,_,"'---r--- Project Address (legal) -4--~~:....:..~~~~:..?..::::~.:::.L~~..!..:,!.~.l,U.~.w.,,...::.._---- Building Perm it No. _ __,,8.,.5"-C4..,.6._.7_-_.B..._ __ _ Plan File No. __________ _ Architect -========:J~Jrri;;~~;~::~~~::=:=:===== Engineer_ Govt. Contract No. ________ _ Census Tract No. ________ _ Contractor ________ K_o_l_l __ C __ o""'n __ s-t""'r"""u""'c""'t .... ,,.,· o .... n ...... C ... o..,..m ... p ... a .... n....,y.__ _______ _ Other ____________ _ INSPECTION CODE MATL SAMPLING CODE MATERIAL DESCRIPTION Reinforced Concrete SIC Concrete Cylinders cc X Reinf.: Rebar A615 ~ Steel: ___ A_3_6 _____ _ Prestressed Concrete SIPC Mortar Samples MS Rein!.: W.W.F. _______ _ Metal Decking: x Reinforced Masonry SIM Grout Samples GS Struct. Steel Assembly Fireproofing FP Rein!.: Tendons ______ _ Cone.: Mix #/psi, ______ _ Shear Connectors: H.S. Bolts: x 1. Shop Fabrication SISS·1 Units (block or brick) UB 2. Field Welding SISS·2 A.G. Concrete ACC Cone.: Mix #/ps.,;· _______ _ Cone.: Mix #/psi ______ _ _L Electrades: 7018 _L Electrodes: 8018 3. H.S. Bolting SISS-3 Rooting RS Cone.: Mix #/psi ______ _ _L Cert. Welders: Yes Pile Driving SIPO Reinf. Steel ASS Grout: Mix #/psi, ______ _ Fireproofing: Nondestructive Testing Steel ss Mortar: Type/psi ______ _ A.G. Concrete: 1. Shop SINOT·1 Tendon (PT Strands) TS Units: Block _______ _ Other: 2. Field SINOT·2 Other· Units: Brick _______ _ Other: Fireproofing SIFP Other Roofing IA Other Waterproofing IWP Other Asphalt Paving IAP Other 10 REC E:IVED CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, co~1~e~ !ith ~PP:~ved~lan~pecifications and applic??I~ sectio~s of the b~ildi~g law~. This repqrt covers the locations of ~r~~~ iM~Ctpil.J\.mttaS r,1\>~i_,;e if you need more specific information regarding inspection procedures. l,j I T Ur vMT\ L :::::~::: oAre ~ ;;;~8:arci a < W-313) Bui 1: iio' ~~;t~: ) q ~ ~t{V Special Inspection -Field Welding '/'-' 't:, / Inspected the welding·of tilt-up precast panel beam seat-to-plate conn ctions at panel 13. Inspected the welding of precast, tilt-up wall panel, chord bar connections panels 1-2. 7/28/86 Special Inspection -Field Weldin 2195 Faraday Avenue Building D Bldg. P.~~~~-~--~-~-467-=!:J Inspected the welding of precast, tilt-up wall panel, chord bar connection at panel 15-16. 7/28/86 Special Inspection -Field Welding 2235 Faraday Avenue Building F Bldg. Permit# 85467-F Inspected the welding of tilt-up precast wall panel hold down connections at panel 3. American Engineering Laboratories. Inc. 7574 Trade Street. San Diego. California 92121 Telephone (619) 695-3730 FILE NO P-548 SUMMARY OF ·coMPRESSION TEST RESULTS PAGE ___ -'-1 ___ _ JOB: ADDRESS· YEAR: CRC MULTI 1S1 PHASE II 2185 Faraday Carlsbad, CA THE KOLL COMPANY 1986 •STORED 8: CURED. NOT TESTED LAB. NO. 1835 1862 1863 [)ATE CAST MO. DA. 6/12 6/13 6/13 LOCATION IN STRUCTURE Panel #1. Panle #3. Panel #14. 3 3 3 1868 6/13 Panels 3 and 4, building D. 3 1902 6/19 Pane 1 #23 •. RECEIVED JUl$@1& CnY OF CARLSBAD 8tlildin1 Department 2-The Koll Company 1-Carlsbad Reasearch Center 1-Conwell-Marshall & Assoc. 1-Construction Serveillance Services 1-Kahn Associates, Attn: Steve Mayorga 1-City of Carlsbad 3 Concrete SPECIFIED 3000 MATERIAL: -------28-DAY 5TR.: ------Psi PROPORT1ONs/Mix No., 50-6315 Premixed Concrete Co TYPE: -----CEMENT: 5• 7 sk. SPEC. 5LUMP, __ 4 __ IN. Pozz. 322N 1 ADMIXTURE: __________ AGG. SIZE. ____ .IN. ULTIMATE COMPRESSIVE STRENGTH. PSI SLUMP IN. 4 4 4.5 4 5 7-OAY 2620 2740 2190 2720 2510 OTHER 1----------,----'-'---··--·-2~-DAY TEST RESULTS AGE DATE MAILED AMERICAN ENGINEERING LABORATORIES. INC. ' ' l, Jj.,y_,__,,._, \____ G:,c,,~ WILLIAM L. COCHRANE, R.C.E~ #24445 ,, American Engineering Laboratories. Inc~ 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 F1L.E No P-548 SUMMARY OF COMPRESSION TEST RESULTS PAGE 1 Joe: CRC MULTI I S, PHASE II . ~ 2185 Faraday Avenue AooREss, Carlsbad, CA THE KOLL COMPANY YEAR: 1986 0 5TOREO 8: CUREO. NOT TESTEO CATE L.A8, NO. CAST L.OCATION IN STRUCTURE MO. DA. 1568 5/19 Building 4 slab-on-grade 20 1 south of north edge (center). 3 - 1625 5/23 Footing B.8 (5.5 to 7) and exit footing, C (6.25 to 7). 3 - 1664 5/27 Slab-on-grade line B.5-C ( 6 to 7). 2 - 1665 5/27 Slab-on-grade line A to A.5 ( 5 to 6). 2 - }666 5/28 Slab-on-grade line E to D (1 to 2). 3 - 1557 5/8 Footing at building D, line A. 2 ( 1 to 1. 4) . 3 - 1567 5/8 Footing at building D, line A ( 4 . 7 to 5 . 1 ) . 3 - 1683 5/29 Slab-on-grade lines C to D (13 to 14). 3 - 2-Koll Construction Company 1-Carlsbad Research Center, Attn: Charlie Abdi 5PECIFIEO MATERIAL.: _C"-'o_n_c_r-"-et_e __ 28-DAY STR.: _____ 2c....,o ..... o ____ o ___ PSI PROPORTIONS/MIX NO.: 51-3164 Premixed Concrete Co. TYPE:-----CEMENT: 5 • 2 S k •SPEC. SL.UMP: __ 4,___ IN. AoM1xTuRE, __ P_oz_z_._3_2_2_N ____ AGG. s,zl!, __ 1 __ .IN. ULTIMATE COMPRESSIVE STRENGTH. PSI SL.UMP IN. 5.5 6 4 4 5.5 4.5 5.5 5.5 7,0AY 28',0AY 2830 3730 3630 2160 3150 3060 2300 3570 2550 3820 1730 3040 2900 4120 4030 4070 3080 3180 3220 1840 3360 3250 TES'?' AGE OTHER !'!!::SU!..TS CATE MAILl!0 ~UN 6 1986 JUN 2 0 1986 AMERICAN ENGINEERING LABORATORIES, INC. 1-Conwell-Marshall & Assoc., Attn: Harlan Tande Juo~~ct.G'::-t3:--l-Constructi6n Serveillance Services Attn: Jack Hanssel 1-Kahn Associates, Attn: Steve Mayoraga 1-City of Carlsbad wrLLIAM L. COCHRANE, R.C.E. #24445 ,, American Engineering Laboratories, Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 .. ( ., " FILE No P-548 SUMMARY OF COMPRESSION TEST RESULTS PAGE-~-- Joe, CRC MULTI'S, PHASE II 2185 Faraday Avenue ADDRESS· Carlsbad, CA KOLL CONSTRUCTION COMPANY YEAR: 1986 •STORED Sc CURED. NOT TESTED DATE LAB. NO. CAST LOCATION IN STRUCTURE MO. 0A. 1868 6/13 Panels 3 and 4, building 2-Koll Construction Company D. .3 - SPECIFIED MATERIAL, ---'C=o"""n.,_,c:-,.r--=e"""t'""'e'--2e-DAv STR., --~3=0=00~--Ps1 PROPORTIONS/MIX NO.: 50-6315G Premixed Concrete Co. TYPE: -----CEMENT: 5, 7 sk, SPEC. SLUMP ___ 4 __ IN. ADM1xTuRE, __ P_o_z_z~. _3_2_2_N ____ AGG. s1zE-_3_./_8 __ .IN. ULTIMATE COMPRESSIVE STRENGTH. PSI OTHER DATE: SLUMP 7-DAY 28-0AY TEST RESULTS IN. AGE MAILED 4 2720 AMERICAN ENGINEERING LABORATORIES, INC. 1-Conwell-Marshall & Assoc., Attn: Harlan Tande 1-Kahn Associates, Attn: Steve Mayoraga 1-Construction Surveillance Services Attn: Jack Hanssel 1-Carlsbad Research Center, Attn: Charlie Abdi 1-City of Carlsbad WILLIAM L. PATRICK, R.C.E. #35256 111 American Engineering Laboratories, Inc. 7574 Trade Street. San Diego, California 92121 Telephone (619) 695-3730 FIL.E No P-548 SUMMARY OF COMPRESSION TEST RESULTS PAGE ___ -'1 ____ _ : Joe, ADDRESS· Y.EAR: CRC MULTI'S, PHASE II 2115 Faraday CaJlsbad, CA THE KOLL COMPANY 1986 "STORED 8: CURED. NOT TESTED L.AB. NO 1835 1862 1863 1868 1902 1935 1936 DATE CAST MO. DA. 6/12 6/13 6/13 6/13 6/19 6/23 6/23 L.OCATION IN STRUCTURE Panel #1. Panle #3. Panel #14. Panels 3 and 4, building Panel #23 .. Tilt-up wall panel #11. Tilt-up wall panel #12. 2-The Koll Co~pany 1-Carlsbad Reasearch Center 1-Conwell-Marshall & Assoc. 1-Construction Serveillance Services 1-Kahn Associates, Attn: Steve Mayorga 1-City of Carlsbad 3 3 3 D. 3 - 3 - 3 - 3 - C SPECIFIED MATERIAL.: __ o_n_c_r_e_t_e __ 28-DAY STR 3000 _______ Ps1 PRoPORnoNs/Mix No, 50-6315 Premixed Concrete Co TYPE: -----CEMENT: 5• 7 Sk"SPEC. SL.UMP. __ 4 __ IN Pozz. 322N 1 ADMIXTURE: __________ AGG. SIZE ----IN. ULTIMATE COMPRESSIVE STRENGTH. PSI SL.UMP IN. 4 4 4.5 4 5 7-DAY 2620 2740 2190 2720 2510 2530 2670 OTHER 28 DAY TEST RESULTS A= ,o\~(~ ' ~~\ / DATE MAILED AMERICAN ENGINEERING LABORATORIES. INC. · · ), 1J.,>ii,,-,_, t.__ G~cl11~ WILLIAM L. COCHRANE, R.C.E. #24445 American Engineering Laboratories. Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 FIL.E No. P-548 SUMMARY OF COMPRESSION TEST RESULTS PAGE 1 Joe, ADDRESS· YEAR: 21~Faraday arlsbad, CA THE KOLL COMPANY 1986 •STORED & CURED. NOT TESTED L.AB. NO. 1835 1862 1863 1868 1902 1935 1936 DATE CAST MO. DA. L.OCATION IN s·rRUC)"URE 6/12 Panel #1. 6/13 Panle #3. 6/13 Panel #14. 3 3 3 6/13 Panels 3 and 4, building D. 3 6/19 Panel #23. 3 6/23 Tilt-up wall panel #11. 3 6/23 Tilt-up wall panel #12. 3 C SPECIFIED 3000 MATERIAL.: __ o_nc_r_e_t_e __ 28-DAY STR., ______ Psr PRoPoRnoNs/Mix No., 50-6315 Premixed· Concrete Co TYPE: ----CEMENT: 5• 7 Sk. SPEC. 5LUMP ___ 4 __ IN. Pozz. 322N 1 ADMIXTURE: __________ AGG. SIZE: ____ .IN. ULTIMATE COMPRESSIVE STRENGTH. PSI SL.UMP IN. 4 4 4.5 4 5 7-DAY 2620 2740 2190 ·2120 2510 2530 2670 28,DAY 3660 3750 3980 3890 3480 3400 3640 3570 3780 3890 3800 3750 3960 4030 OTHER TEST RESULTS AGE DATE MAILED JUL 11 1986 1995 6/27 Panels 5 and 6. 3 5.25 2490 3180 3240 1996 2082 2206 6/27 Panel 24 -building E. 7/7 Panels #5 and #8. 7/15 Panel #6. 2-The Koll Company 1-Carlsbad Reasearch Center 1-Conwell-Marshall & Assoc. 1-Construction Serveillance Services 1-Kahn Associates, Attn: Steve Mayorga 1-City of Carlsbad 3 5.25 3 5 5 2870 2650 2440 3700 3730 3820 3710 3710 8-days 2560 AMERICAN ENGINEERING LABORATORIES. INC. ' , l f}-~"'"'-, I___ &,c~ WILLIAM L. COCHRANE, R.C.E~ #24445 111 ' < FILE No. P-548 American Engineering Laboratories. Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 SUMMARY OF COMPRESSION TEST RESULTS PAGE 1 JOB: ~~~~;I'S~ P-H~ · MATERIAL: Concrete SPECIFIED 3000 28-DAY STR.: ------Psi 2185-Faraday ,. Carlsbad, CA PROPORT1ONs/M 1x No.: _5_0_-_6~3_1 ~5~P_r_e=rn~i_x~ed~C~o~n .... c~r~e~t-=e_C.:;..o::;....__ ADDRESS: THE OLL COMPANY TYPE: _____ CEMENT: 5• 7 sk, SPEC. S1.UMP; __ 4 __ IN. 1986 YEAR: Pozz. 322N 1 ADMIXTURE: __________ AGG. SIZE:----.IN. •STORED 8c CURED. NOT TESTED ULTIMATE COMPRESSIVE STRENGTH. PSI DATE LAB. NO. CAST LOCATION IN STRUCTURE SLUMP IN. 1835 1862 1863 1868 1902 1935 1936 1995 1996 . 2082 MO. DA. 6/12 Panel #1. 3 6/13 Panle #3. 3 6/13 Panel #14. 3 6/13 Panels 3 and 4, building D. 3 6/19 Panel #23. 3 6/23 Tilt-up wall panel #11. 3 6/23 Tilt-up wall panel #12. 3 4 4 4.5 4 5 6/27 Panels 5 and 6. 3 5.25 6/27 Panel 24 -building E. 3 5.25 7/7 Panels #5 and #8 . 3 7,OAY 2620 2740 2190 2720 2510 2530 2670 2490 2870 2650 D 28-DAY 3660 3750 3980 3890 3480 3400 3640 3570 3780 3890 3800 3750 3960 4030 3180 3240 3700 3730 3820 3710 OTHER TEST RES UL TS AGE DATE MAILED JUL 11 1986 2-The Ko 11 Company RlSBAD AMERICAN ENGINEERING LABORATORIES. INC. 1-Carlsbad Reasearch Center CITY OF CA 1-Conwell-Marshall & Assoc. Bui~ing Department ) 1-Construction Serveillance Services ~ I ~ / 1-Kahn Associates, Attn: Steve Mayorga 1 \\ .(,x./):-AI"--:'.'.',..~, '-° C:vzt:7'.:"V'-.3:::----- 1-City of Carlsbad l.JILLIAM L. COCHRANE, R. C. E~ #24.445 ii -") .. \ KOLL LETTER OF TRANSMITTAL TO rCity of Carlsbad 1200 Elm Ave. Carlsbad, CA 7. DATE 6/9/86 I JOB NO 52 0 5 RE CRC Multi's, Phase II Permit #85-467 ~ttn.: Building Inspection Department ~/&'51 r,A !?.A DA-( 22-2'1 J WE ARE SENDING YOU:-5a Attached D under separate cover via ______ the following items: D Prints D Shop drawings D Plans D Specifications D Samples D Change order D Copy of letter . Qg AITC Certificate of Conformance COPIES DATE NO. 1 6/2/86 22973A COPV of AITC Certificate of Conformance for alu-lam beams. THESE ARE TRANSMITTED AS CHECKED BELOW: D for approval D Approved as submitted D Resubmit __ copies for approval @ for your use D Approved as noted D Submit __ copies for distribution @ As requested D Returned for corrections D Return __ corrected prints D For review and comment D D FOR BIDS DUE __________ 19 __ O PRINTS RETURNED AFTER LOAN TO US REMARKS RECEIVED JUN 111986 CITY OF CARLSBAD co PY TO __.:C::....:o=n=w.:....:e::....:l=-=l=----=M=a=r=--=s=h=a::..:1::..:1::__;&=----:A:..::..,S::,_:S:::..;O:::..;C=--=-.. L-l w / enc 1 o siu:Hd i ng De pa rtm en t Khan Associates, w/enclosure K-163 1/85 Field g File SIGNED CL~ If enclosures are not as noted, kindly notify LIS at once _)--' ~~ Ron S. Brockhoff Project Engineer .. ~ 1'., ,...;-_ .. ~"'~ .... -£-1/~ ~\)TE OF TIM8A . ' ~, ' '?' ~ °iA1Tcl CER IFICATE OF < ® z. CONFORMANCE ·., ¢tiftM HE UNDERSIGNED-MANUFACTURER HEREBY CERTIFIES that the products identified below and on attached sheets Nos. __________ are marked with the Collective Mark of the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) and were manufactured in conformance with applicable provisions of American National Standard ANSI/ AITC A 190.1-1983', Structural Glued Laminated Timber, a~d that such manufacture has been at our plant in SPRINGFIELD. OREGON , which plant has a quality control system approved by the Inspection Bureau of the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION and inspected periodically by such B1,1reau. The manufacture of these members complies with the manufacturing and fabricating provisions of Chapter 25 of the Uniform Building Code. JOB NAME: 3611-CRC MULTIS (DUKE PACIFIC) JOB LOCATION: CARLSBAD CA . -,,,.. 3611[ .5 J.31 CUSTOMER'S ORDE[R NO. DATE 3/27 /86 ,r,,FGR'S 0 ORDER NO. 6942-G l " TITLE OUALI1Y CONTROL ADDRESS __ S_0_2_2_ND_S_T_R_E_E_T ___ OATE __ 6_/_2_/_8_6 ____ _ A/TC HEREBY CERT/ff ES that the said company at its said plant is licensed by the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION to use the AITC Collective Mark in respect of products which comply with applicable provisions of said Standard, that the adequacy of the quality control system in effect at said plant is periodically inspected and verified by the Inspection Bureau of the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, and that, in the judgment of AITC, said company is capable of complying with applicable manufacturing and testing provisions of said Standard in respect of products manufactured at saicA plant. Conformance with the Standard in respect of any specific or particular product is the sole responsibility of the manufacturer; AITC's guarantee hereunder being that the said company is qualified to produce a product meeting the said Standard and that its plant is periodically inspected and verified by the AITC Inspection Bureau. AITC FORM IBCA AITC Certificate No. 2 2 9 7 3 A AMERICAN INSTITUTE OF TIMBER CONSTRUCTION © 1983 AMERICAN INSTITUTE OF TIMl;IER CONSTRUCTION American Engineering Laboratories. Inc. 7574 Trade Street. San Diego, California 9212fL.UG OJ 'dbo Telephone (619) 695-3730 - INSPECTION REPORT ;· ~ . . •. ,.,,:= :<,_;u .... Cd Date _______ 8;;;.:/"-1..:./.,..8_6 ____ Project,No._P_-_5_4_8 __________ Report NoAEL 6U-45 2/1 c1~nt KOLL CONSTRUCTION COMPANY Cllent Address 7330 Enci neer Road San Q;e~2, CA 92111-1 464 Project Name (per plans)" CRC MULTI I S, PHASE I I -BU I LO I NG D Building Permit No • .a.#_8_5_-4...,_6_7...,&,.__ ___ _ Project Address (legal) 2195 Faraday Avenue, Carlsbad Plan File No. __________ _ Architect ______ _,C..,o:..:.n'--'-w'-"e'""l'-'l'--..:..M:.a::a...,_r-=s'-'-'h-=a...:.l...:.l--=&~A:.a::s-=s-=o-=c...:.i-=a;..;;t_e-=s'---________ Govt. Contract No. ________ _ Engineer Kahn Associates Census Tract No. ________ _ contractor Ko 11 Construction Co. Other ____________ _ INSPECTION CODE MATL SAMPLING CODE MATERIAL DESCRIPTION -Reinforced Concretl! SIC ---c.n:ret11 Cylinders cc --Reint; Rebar -X-Steel: ,£336 --Prestressed Concretl! SIPC -llatar Samples MS --Reint; W.W.F. -Metal Decking: Reinforced Masonry SIM -l:iaJt Samples GS --Reint; Tendons -Shear Connectors: X StrucL Steel Assembly _ Fireproofing FP --Cone.: Mix #: /pSi -H.S. Bolts: --1. Shop Fabrication SISS-1 -Lnts (block or brick) us --Cone; Mix #:/psi -X-Electrodes: :.z.orn V 2. Field Welding SISS·2 _ AC. Concret11 ACC --Cone.: Mix #: /pSi -Electrodes: ---3. H.S. Bolting SISS-3 -Rlo1ing RS --Cone.: Mix #:/pSi -X-Cert. Welders: : yes __ Pil11 Driving SIPO _ Feint. Steel RSS --Grout: Mix #: /pS. -Ftreproofing: --Noodestructiv11 Testing -~ ss -Mortar. Type/psi -A.C. Concret11: --1. Shop SINOT·1 _ Tendon (PT Strands) TS -Units: Block -Other: --2. Field SINOT·2 -Cttler -Units: Brick -Other: --F1teproofing SlFP -Ct!ler ---Rooling IR -Ct!ler RECEIVED Waterproofing IWP Cttler -----Asphalt Paving IAP AUG 5 1gss --Other '0 &tnl I ,-.,-I ,.. CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the builcing laws. This repoi;t covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR INSPECTION DATE Jinnv L. Garcia (W-313) 7/23/SE Special Inspection -Field Welding Inspected the welding of pre-cast, tilt-up low wall panels of p1ate-to- plate conn~ction at panels W3 to W4 and ~4 to 19. 2-Client 1-Architect 1-Engineer 1-Lender 1-CRC 1-City of Carlsbad 11/ American Engineering Laboratories, Inc. 7574 Trade Street. San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date 8/20/86 Project No. _____ P-_54_8 _______ Report No ....... __ A_E_L_6_-_K_1_4_8 __ Client _____ __,;,,;,,KO=L=L~CO=N.:.aSa..;.T.:.;:R.;a..UC--'T"""I"""O.;.,;,.N.....;Ca.aO'"'"'M.;..;PA __ N"""'Y _______________________ _ Client Address _,_..;,.7.;:;.3.;:;.3.;;;..0.,,._.En;.;.g.._1.;.;· n;.;.e~e;,..;r,--R...,o,..,ae--ed;..,...,,,......,,-:-,:,-:-----------------------------San Diego. cA 92111-14§4 Project Name (per plans) Project Address (legal) Architect CRC MULTI I S PHASE II ( Job #5205) -BLDG. 11 D" Building Permit No. _ ___,;;;.8.;;;.5-_4..;..;6'""7_-.;;;.D __ 2195 Faraday Avenue, Carlsbad, CA PlanFileNo. _________ _ Conwell-Marshall & Assoc. Govt.ContractNo. ________ _ Engineer Kahn Associates Census Tract No. ________ _ Contractor Koll Construction Company Other ____________ _ INSPECTION CODE MATL SAMPLING CODE MATERIAL DESCRIPTION Reinforced Concrete SIC Concrete Cylinders cc Reinf.: Rebar _ Steel: Rein!.: W.W.F. -Prestressed Concrete SIPC Mortar Samples MS Metal Decking: X Reinforced Masonry SIM Grout Samples GS Rein!.: Tendons Shear Connectors: Struct. Steel Assembly Fireproofing FP Cone.: Mix #/psi H.S. Bolts: 1. Shop Fabrication SISS-1 Units (block or brick) UB Cone.: Mix #/psi Electrodes: 2. Field Welding SISS·2 A.C. Concrete ACC Cone.: Mix #/psi Electrodes: 3. H.S. Bolting SISS·3 Roofing RS Cone.: Mix #/psi Cert. Welders: Pile Driving SIPD Rein!. Steel ASS Grout: Mix #/psi Fireproofing: Nondestructive Testing Steel ss Mortar: Type/psi A.C. Concrete: 1. Shop SINDT·1 Tendon (PT Strands) TS Units: Block Other: 2. Field SINDT·2 Other Units: Brick Other: Fireproofing SIFP Other Roofing IR Other Waterproofing IWP Other Asphalt Paving IAP Other 10 CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR INSPECTION DATE Jinny Garcia (W-313) 8/16/86 Special Inspection -Roofing Inspected the in process application of roofing materials in accordance to plans specifications and applicable sections of the building code at Building D, Lines B.5 -E (1-FL) 2-Client 1-Architect 1-Engineer 1-Car1sbad Research Center 1-Construction Surveillance 1-City of Carlsbad Building Dept. RECEIVED AUG 2 2 1986 THE KOLL CO. 117 American Engineering Laboratories, Inc. 7574 Trade Street. San Diego. California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date 8/14/86 Project No. ____ P_-_54_8 ________ Report No __ A_E_L_6_-_K_1_3_4 __ _ Client ____ .:.:.;KO~L::.::L..._..C=ON...,S""'T'-'-'R=U=CT.:...I...,O:.:..:N:...=CO=M.,_,_P.:...A=N.:...':f _______________________ _ Client Address __ :...7:::!.3:::!.3::::.0-=.E.:.:n.::19..!.i.:.:n.=.e.=.e.:...r-.:.!R::::.o.:::.a::::.d __ __,,,..,.....----------------------------Sg n Qjego, GA 92111 1464 Project Name (per plans) __ __.C..._R...,.C'-"-'M"""U ... L.._T..._I ...:' S,._,,.__._P"""H"'-A=S-=E--=-I __ I~· _.B""'U"""I...,L=D--=I"""N'""G'---=D____ Building Perm it No. _..:::8:.a:5_,_4=6.:...7 -...:D::...--__ _ Project Address (legal) ____ 2 .... ]..,.9 .... 5 ____ F__,a..._r ... a=d=a .... v ____ A ___ v'""e ... n=u.._e...,, ___ C_a...,r __ l __ s_b __ a __ d~,---C_A_____ Plan File No. __________ _ Architect ________ __..C..,o ... n...,w .... e ... J .... J .... -..... M...,a"-'r-'s"-'h-'-'a=-1"-'-l _&=-A--=-s=s=o.:.c .... i...:a~t~e~s----------Govt. Contract No. --------- Engineer _____________ K..,:a"""h""'n....__A ___ s,__s,.._o"-c=-1_,_· a=t""e"""""s ______________ Census Tract No. _________ _ Contractor Koll Construction Co. Other _____________ _ INSPECTION CODE MArL SAMPLING CODE MATERIAL DESCRIPTION X Reinforced Concrete SIC _ Concrete Cylinders cc Rein!.: Rebar __ . Steel: --''---------- Prestressed Concrete SIPC Mortar Samples MS Reinf.: W.W.F. Metal Decking: _______ _ Reinforced Masonry SIM Grout Samples GS Rein!.: Tendons Shear Connectors: ______ _ Struct. Steel Assembly Fireproofing FP Cone.: Mix # /psi H.S. Bolts: ________ _ 1. Shop Fabricati011 SISS·l Units (block or brick) UB Cone.: Mix #/psi Electrodes: ________ _ 2. Field Welding SISS-2 A.G. Concrete ACC Cone.: Mix # /psi Electrodes: ________ _ 3. H.S. Bolting SISS-3 Roofing RS Cone.: Mix #/psi Cert. Welders: _______ _ Pile Driving SIPD Rein!. Steel ASS Grout: Mix #/psi Fireproofing: Nondestructive Testing Steel ss Mortar: Type/psi A.G. Concrete: _______ _ 1. Shop SINDT-1 Tendon (PT Strands) TS Units: Block Other: _________ _ 2. Field SINDT-2 Other Umts: Brick Other: _________ _ Fireproofing SIFP Other Roofing IR Other Waterproofing IWP Other Asphalt Paving IAP Other 10 CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR INSPECTION DATE John Mauk 8/13/86 Special Inspection -Roofing Roofing being done to specifications, with proper materials. 2-Client 1-Architect 1-Engineer 1-Contractor 1-Carlsbad Research Center 1-City of Carlsbad Bldg. Dept. 117 American Engineering Laboratories, Inc. 7574 Trade Street. San Diego, California 92121 Telephone (619) 695-3730 KtGEIVED AUG 2 0 1986 THE KOLL CO. INSPECTION ·REPORT Date 8/15/86 Project No. _____ P_-_5_4_8 ______ Report No· ___ A_E_L_6_-_K_13_7 __ Client ___ ___.:K~O~L..:.L_C~O~N!.:::S:..!.T.!.!.R~UC~T~I~O.!.!.N....:C~O:.:..M:.:...P.:..;;AN:.:..Y;...._ ______________________ _ Client Address __ 7.:...:3:::.;3:::.;0~E~n:.:.;g::t..:..i n:.:.;e::::.e::::.:,_r_:..:,Ro:::..a:::.d:::,_ _______________________________ _ San Qieag. CA 92J]]-J464 Project Name (per plans) CRC MULTI'S PHASE II (Job #5205) Bldg. D Building Perm it No. _ ___,;:;8--=5_-....:4....::6...:..7_---=D __ _ Project Address (legal) 2195 Faraday Avenue I Carlsbad, CA Conwell-Marshall & Associates Plan File No. __________ _ Architect Govt. Contract No. ________ _ Engineer Kahn Associates Census Tract No. _________ _ Contractor Koll Construction Company Other _____________ _ INSPECTION CODE MATL SAMPLING CODE MATERIAL DESCRIPTION X Reinforced Concrete SIC Concrete Cylinders cc Reinf.: Rebar _______ _ Steel: _________ _ Prestressed Concrete SIPC Mortar Samples MS Reinf.: W.W.F. _______ _ Metal Decking: _______ _ Reinforced Masonry SIM Grout Samples GS Reinf.: Tendons _______ _ Shear Connectors: ______ _ Struct. Steel Assembly Fireproofing FP Cone.: Mix #/psi _______ _ H.S. Bolts: ________ _ 1. Shop Fabrication SISS-1 Units (block or brick) UB Cone.: Mix #/psi _______ _ Electrodes: ________ _ 2. Field Welding SISS-2 A.C. Concrete ACC Cone.: Mix #/psi, _______ _ Electrodes: ________ _ 3. H.S. Bolting SISS-3 Roofing RS Cone.: Mix #/psi, _______ _ Cert. Welders: _______ _ Pile Driving SIPD Rein!. Steel RSS Grout: Mix #/psi _______ _ Fireproofing: Nondestructive Testing Steel ss Mortar: Type/psi _______ _ A.C. Concrete: _______ _ 1. Shop SINDT-1 Tendon (PT Strands) TS Urnts: Block Other: _________ _ 2. Field SINDT-2 Other Units: Brick. ________ _ Other: _________ _ Fireproofing SIFP Other Roofing IR Other Waterproofing IWP Other Asphalt Paving IAP Other 10 CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR INSPECTION DATE John Mauk 8/14/86 Special Inspection -Roofing Roofing continuing according to specifications. 8/15/86 Special Investigation -Roofing Roofing continuing according to specifications. 2-Client 1-Architect 1-Engineer 1-Lender 1-City of Carlsbad 11~ American Engineering Laboratories, Inc. 7574 Trade Street, San Diego, California 92121 Telephone (619) 695-3730 INSPECTION REPORT Date _______ 9~/,..;1;;.,;5"""/..;;;.8~6.,.,..,,.,,,.,,.,..,.,,..,,,, Project No . .,..-._P_-___ 5 __ 4_8 _________ Report No AEL 6-H184 Client KOLL CONSTRUCTION GOMPANY Client Address 7330 Engineer Road San Diego. CA 92111-1464 Project Name (per plans) CRC MULTI I S 2 PHASE I I Building Permit No . ..a:8=5_-,..:..4.::..67'--'D"----- Project Address (legal) 2195 Faraday Ave., Carlsbad, CA (Bldg. D) PlanFileNo. _________ _ Architect ________ C ___ o_n __ w"""e ..... 1 .... 1_-_M_a __ r_s'""h"'"'a"""l ..... l'--'&_A_s_s_o_c_,_· a_t_e_s___________ Govt. Contract No. ________ _ Engineer Kahn Associates CensusTractNo. ________ _ contractor Ko 11 Construction Company Other ___________ _ INSPECTION CODE MATL SAMPLING CODE MATERIAL DESCRIPTION Reinforced Concrete SIC Concrete Cylinders cc Rein!.: Rebar _ Steel: \ Prestressed Concrete SIPC Mortar Samples MS Reinf.: W.W.F. Metal Decking: Reinforced Masonry SIM Grout Samples GS Reinf.: Tendons Shear Connectors: Struct. Steel Assembly Fireproofing FP Cone.: Mix #/pSi H.S. Bolts: 1. Shop Fabrication SISS-1 Units (block or brick) UB Cone.: Mix #Jpsi Electrodes: 2. Field Welding SISS-2 _ A.C. Concrete ACC Cone.: Mix #/psi Electrodes: 3. H.S. Bolting SISS-3 Roofing RS Cone.: Mix #/psi Cert. Welders: Pile Driving SIPO -Reinf. Steel RSS Grout: Mix #/psi Fireproofing: Nondestructive Testing Steel ss Mortar: Type/psi A.C. Concrete: 1. Shop SINOT·1 Tendon (PT Strands) TS Units: Block Other: 2. Field SINOT-2 Other Units: Brick Other: Fireproofing SIFP Other -X-Roofing IR Other __ Waterproofing IWP Other Asphalt Paving IAP --Other IQ CERTIFICATION OF COMPLIANCE: All of the reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building laws. This report covers the locations of the work inspected. Contact this office if you need more specific information regarding inspection procedures. INSPECTOR John Mauk INSPECTION DATE __ 8""'/...;;1=9.,_/.;:;..86;;._ ________ _ Special Inspection -Roofing (Bldg. D) CC: Inspected application of cap sheet installation and mastic work of all penetration for completion of all roofing at this building. 2-Koll Construction Company 1-Conwell-Marshall & Associates 1-Kahn Associates ·1-Construction Surveillance Services 1-Carlsbad Research Center 1-City of Carlsbad 117 r ~ • • , .. _, 1200 ELM AVENUE C!Citp of Carl~bab PAGE 1 OF_ . CARLSBAD, CA 92008-1989 FIRE DEPARTMENT TELEPHONE (619) 438-5523 APPROVED ' . ,\/ t .1\ DISAPPROVED PLAN CHECK REPORT l) PLf~CHECK# /J -4t1 ---PROJECT /r.,1u,,,. 1/)f./tTt $ -~f/lStE.5::C ADDRESS ______ --i-_L_4_,..-:_'/'._l_-6_,_·ti_/_· ______ _ ARCHITECT---'----~--"----~----ADDRESS _________ PHONE _____ _ OWNER ADDRESS _________ PHONE occuPANcv :z-z--coNsT. v-N TOTALsa. FT. 1t'/tfo7 sToRIEs Jl(SPRINKLERED D TENANT IMP. __ 1. __ 2. __ 3. ){ 4. __ 5_ y 6. \1 _l-_1. APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets ___________________ _ Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. Provide specifications for the following: Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, CO2, alarms, hydrants). Plan must be approved by the fire department prior to installation. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT 11Je following fire protection systems are requiresJJ &J,., 1, A-, /4 Ip Automatic fire sprinklers (Design Criteria: _ __,IV'-"--'-1rt-'-'-·r-i-----':;i--"'~,a=· C.-,,/_'-'_=~-"J,,_,/)~'(11..,_} ____________ _ o Dry Chemical, Halon, CO2 (Location: _________ , _______________ _ D Stand Pipes (Type: . 1 _M Fire Alarm (Type/Location: (:.;::N17L,AL S,7J177 p,,.J :+t..(,,,w 'f i//lu/~ /110,-J 1ro,,::-1A)G ~e Extinguisher Requirements: /' "/} ~JCµ .. ~U 11-/E. [i(rt(i/£ /;l,.::;-0J kl One 2A rated ABC extinguisher for each :7/Jt, sq. ft. or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. D An extinguisher with a minimum rating of ___ to be located: 1 / D Other: ______________ -;:,--.,,.---,,.,-----,,-----=-------------- _/_: 8. Additional fire hydrant(s) shall be provided __ ·<"~~=~~r~·-·· __ c_~,,_r~-J_Z_.,_.::,,..,~/1_.._... ___________ _ V _._9_ l10. V' 11. ;' EXITS Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. A sign stating, " This door to remain unlocked during business hours" shall be placed above the main exit and doors----------------------------------- EXIT signs (6" x ¾" letters) shall be placed over all required exists and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL ~-1,2c:\ Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and .. ,,,-1 · 1 hazardous chemicals shall comply with Uniform Fire Code. , / Y 13. __....-~uilding(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet t__ ________ _.. in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. J( 14. Aggl_t1onaI-Be,quirements. -----------------------------H....:.av1, 9£ Sll1re£. Alt//J18r.sl.,A..JG ,,,:521/ 1 h·n£ ,,,;/S/Ji_:.7 V _,_15. { Complywittu,egulatiof').s.,on attached sheet(s). .... / / -~ . -r· I~ )--, ·1:>l,,,·1.~/"'i; , Plan Examiner ,,-· -· c.-:? 6,-' --,1/-) Dale·--~------- Report mailed to architect ___ Met with _____________ _ __ Attach to Plans