HomeMy WebLinkAbout2200 CAMINO ROBLEDO; ; CB111068; Permit05-23-2011
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Cogeneration Permit Permit No:CB111068
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
2200 CAMINO ROBLEDO CBAD
COGEN Sub Type:
2552613600 Lot#:
$0.00 Construction Type:
Reference #:
HIERS: 40AMP CIRCUIT? MENA 6-
50 RECEPT//W/SUB-MERTER
EVG
0
NEW
Applicant:
SUNWEST ELECTRIC INC
3064 E MIRALOMA AV 92806
714630-8700
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
REYNOLDS PETER D&SUSAN H
2200 CAMINO ROBLEDO
CARLSBAD CA 92009
ISSUED
05/20/2011
JMA
05/23/2011
05/23/2011
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Green Bldg Stands (SB1473) Fee
Total Fees: $22.00 Total
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
$1.00
Payments To Date:
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Additional Fees
TOTAL PERMIT FEES
$22.00 Balance Due:
$0.00
$20.00
$0.00
$0.00
$22.00
$0.00
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE rat approval of your project includes the "Imposition" onees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
CITY OF
CARLSBAD
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 /2718/ 2719
Fax 760-802-8558
www.carfsbatica.gov
Plan Check No . (_J&.\ I (
Est. Value
Plan Ck. Deposit
Date SWPPP
JOB ADDRESS 2200 Camino Robledo
#OFUMTS I«BEDROOMS * BATHROOMS (TENANT BUSINESS NWE CONSTRTYPE IOCC.GROUP
DESCRIPTION OF WORK: Include Squan Feet o/A/foc(cd Area(s)
Install 40A circuit and NEMA 6-50 receptacle for Electrical Vehicle Equipment
EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE
YESQ» N(Q
AIR CONDITIONING FIRE SPRINKLERS
CONTACT NAME APPLICANT NAME Shaun Eastman
ADDRESS ADDRESS
3064 E.Miraloma Ave.
CITY STATE ZIP CITY
Anaheim
STATE CA ZIP 92806
PHONE FAX PHONE
714-678-0083
FAX
714-630-8740
EMAIL EMAIL
seastman@sunwesteiect.com
PROPERTY OWNER NAME Susan Reynoids CONTRACTOR BUS. NAME Sunwest Electric, Inc.
ADDRESS
2200 Camino Robledo
ADDRESS 3064 E. Mlraloma Ave.
CITY
Carlsbad
STATE
CA
ZIP 92009 CITY Anaheim
STATE
CA
zip 92806
PHONE 760-635-0558 FAX PHONE
714-60-8700
FAX
714-630-8740
EMAIL EMAIL
seastman@sunwestelect.com
ARCH/DESIGNER MIME & ADDRESS
511697 C10
cnvBuaucj
1216494
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its Issuance, also requires theapplicant (or such permit to file 3 signed statement that he fs licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of UieBusiness and Professions Code) or that he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 70315 by any applicant for a permit subjects the applicant to a
civil penalty of not more than Hve hundred dollars (5500J).
Workers' Compensation Declaration: I hereby eft.™ under penalty olpetfviy one o/l/ie totMng declarations:BI have and will maintain a certificate of consent to self-Insure for writers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued.
! have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation Insurance carrier and policy
number are: Insurance Co _Old Republic No..
TOs section need not be completed if the permit Is for one hundred dollars ($100) or less.
LJ Certificate of Exemption; I certify that In the performance of the work for
California. WARNING: Failure to secure workers' compensation coverage Is
addition to the cost ol compensaUoj^damagw
^CONTRACTORSIGNATURE
Expiration Dale.
tot employ any person In any manner so as to become subject to the Workers' Compensation Laws of
aa employer to criminal penalties and civil fines up to one hundred thousand dollars (S100,000), In
attorney'sfees^ ^ /
\ 0AGEKT DATE Q/Z^
IherebyaSm fasti em exempt from Contractor's L
[ | I, as owner of the property or my employees with wages as Itielr sole compensation, wi do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Lew does not apply to an owner of property who builds or Improves Biereon. and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have Ihe burden of proving that he did not buSd or Improve for the purpose of safe).
[71 I, as owner of the properly, am exclusively contracting with licensed contractors to consM the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractors) Ecensed pursuant to Ihe Contractor's License Law).
[ [ I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed properly improvement I lYes | JNo
2.1 (have / have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed constacfion (include name address / phone / contractors' license number):
A. I plan to provide portions of Ihe work, but I have hired Vie (Mowing person to coordinate, supervise and provide the major work [Include name I address / phone / contractors' license number):
S. I will provide some of the work, but I have contacted (hied) the following persons to provide the work indicated (include name / address / phone / type of work):
,£f PROPERTY OWNER SIGNATURE [7JAGENT DATE
Is the applicant or future building occupant required to submit a business ota acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25933 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? I""! Yes LJNo
Is the appfeant or tuturs tw'Minj occupant required to oMaln a permit (ram the air solution cofitroUMrtet or ajroualib management district? LjYes I Itio
Is the fscSty to be constaictedwi'ttilfi 1,000 fe«t of tne outer boundary ol a school ste? I lYes flNo
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there Is a construction lending agency for the performance of the work this permit Is Issued (Sec. 3097 (I) CM Code),
Lender's Name n/a Lenders Address
1 hereby authorize representative of the CSyol Cartsbad to enterupon Bie above menfoned properVfwter^wipuixjsas. I ALSO AGREE TO SAVE, INDEWFY AND I€EP HARNESS THE CFTY OF CARLSBAD
ASAJNST ALL UABILfTIES, JUDGMENTS. COSTS AND EXPENSES WHICH MM IN ANY WAY ACCRUE AGAINST SAIO CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA perrrit Is required for excavations over SO deep and demolition or WMtruct* of slructuresoverSslorfes in height
EXPIRATION: Every pemfl issued by the Butding Official under tfca provlstansrfttife Code spl expire by MMon and become mi! and void if the building or roik authorized by such perrrit Is not cormenced within
ITOd^fiomfoedateofsuchperrfteiflhebuMir^wvrorka^-,«__—-»-P^!SSSS=' , f~y^x*: ~ r r^
^APPLICANTSSIGNATURE < "£s&—- -*^'*. / "\ '" DATE
City of Carlsbad Bldg Inspection Request
For: 06/16/2011
Permit* CB111068
Title: HIERS: 40AMP CIRCUIT? MENA 6-
Description: 50 RECEPT//W/SUB-MERTER
Inspector Assignment:
2200 CAMINO ROBLEDO
Lot: 0
Type:COGEN Sub Type: EVG
Job Address:
Suite:
Location:
APPLICANT SUNWEST ELECTRIC INC
Owner: REYNOLDS PETER D&SUSAN H
Remarks:
Phone: 7143157753
Inspector:
Total Time:
CD Description
34 Rough Electric
39 Final Electrical
Act Comments
Requested By: CARLOS
Entered By: JANEAN
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Inspection History
Date Description Act Insp Comments
wm w
-o55 O
S< fi£n O5s gSS o
1
GENERAL NOTES & SPECIFICATIONS (SHEET 1 OF 2)
WORK SPECIFIED HEREIN
WORK UNDER THIS SPECIFICATION INCLUDES FURNISHING ALL MATERIAL.
LABOR. EQUIPMENT, ETC., AND FINAL CONNECTION TO EQUIPMENT IN ORDER
TO PROVIDE THE OWNER WITH A COMPLETE AND PROPERLY FUNCTIONAL
ELECTRIC VEHICLE SUPPLY EQUIPMENT. IN GENERAL, THE WORK SHALL
CONSIST OF BUT NOT BE LIMITED TO THE FOLLOWING:
• FURNISH AND INSTALL ALL OF THE EQUIPMENT AND THE POWER SUPPLY
FOR THE ELECTRIC VEHICLE SUPPLY EQUIPMENT, INCLUDING; CIRCUIT
PROTECTION DEVICES AND BRANCH FEEDERS.
• PRIOR TO INSTALLATION AND FINAL CONNECTION, VERIFY ELECTRICAL
CHARACTERISTICS OF THE DISTRIBUTION SYSTEM AND LOCATION OF THE
EVSE.
• GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND ROOF TO
MAINTAIN FIRE RATING AND WATERTIGHT INTEGRITY OF WALLS AND ROOF.
GENERA! RFrXJIREMFNT?;
THE CONTRACTOR WILL BE HELD TO HAVE THOROUGHLY REVIEWED GENERAL
CONSTRUCTION DRAWINGS, EXAMINED THE SITE, PREMISES AND SATISFIED
HIMSELF AS TO EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGED TO
OPERATE OR WHICH WILL IN ANY MANNER AFFECT THE WORK UNDER THIS
CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN BEHALF OF THE
CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. PROVIDE
STANDARD PRODUCTS OF ESTABLISHED MANUFACTURERS REGULARLY
ENGAGED 1N THE PRODUCTION OF SUCH EQUIPMENT. PROVIDE NEW MATERIAL.
APPARATUS AND EQUIPMENT OF THE BEST PRACTICE OF THE ELECTRICAL
TRADE AND BY SKILLED CRAFTSMEN. ALL EQUIPMENT SHALL BE LISTED BY
UNDERWRITERS LABORATORIES. OR EQUIVALENT NRTL, FOR USE INTENDED.
THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL
HARMONIZE HIS WORK SO THAT EACH PIECE OF EQUiPMENT WILL BE
INSTALLED SO AS TO FUNCTION PROPERLY. COOPERATE WITH OWNER AND
VERIFY ALL EQUIPMENT LOCATIONS. WORK SHALL BE PERFORMED IN
ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS OF STATE, COUNTY,
MUNICIPAL AUTHORITIES. UTILITY COMPANY, N.E.C. AS SHOWN ON
CONSTRUCTION DOCUMENTS.
SEC CONSTRUCTION ORAWNGS FOR EQUIPMENT LOCATIONS. AND APPLICABLE
ELEVATIONS AND DETAILS. ELECTRICAL CONTRACTOR TO VERIFY AND
ACKNOWLEDGE ALL COOES AND REGULATIONS PERTAINING TO THIS PROJECT.
REFER TO THE NATIONAL ELECTRIC CODE, ARTICLE 625 AND ALL OTHER
APPLICABLE SECTIONS OF THE NEC.
C.C&llUJJ.
CONDUITS SHALL BE SIZED IN ACCORDANCE WtTH THE APPROPRIATE TABLE
OF NEC. AND SHALL BE OF SUCH SIZE AND SO INSTALLED THAT
CONDUCTORS MAY BE DRAWN IN WITHOUT INJURY OR STRAIN. CONDUIT
SHALL BE SECURED TO PULL BOXES. SUPPORT BOXES. OR OUTLET BOXES
WITH GALVANIZED LOCKNUTS AND BUSHINGS. ALL CONDUITS SHALL BE RUN
CONCEALED PRINCIPALLY IN OVERHEAD AND WALL CONSTRUCTION.
ALL CONDUIT THAT MUST BE EXPOSED SHALL BE RUN PARALLEL WITH LINES
OF THE BUILDING, CHASES AND OPENINGS IN WALLS, PARTITIONS AND
FLOORS SHALL BE PROVIDED FOR INSTALLATION OF CONDUIT; ALL
CONCEALED WORK SHALL BE DONE SO AS TO MINIMIZE CUTTING AND
PATCHING.
ALL CONDUIT NOT EMBEDDED IN CONCRETE SHALL BE FIRMLY SECURED BY
LISTED PIPE CLAMPS, HANGERS. ETC.
ELECTRICAL METALLIC TUBING: USED FOR ALL WIRING EXCEPT IN OR UNDERCONCRETE, EARTH, FILL, OR GROUTED BLOCK WALLS.
GALVANIZED STEEL CONDUIT: USED FOR ALL WIRING IN OR UNDERCONCRETE, EARTH. FIU. AND GROUTED WALLS. IN EARTH OR FILL. COAT WITH
POLYETHYLENE TAPE, SPIRAL WRAPPED TO NOT LESS THAN 40MILS.
NON-METALUC: LISTED, SCHEDULE 4D. PVC MAY BE USED FOR BRANCH
FEEDER CIRCUITS IF RUN UNDER CONCRETE FLOOR. PROVIDE BONO WIRE PER
NEC. PVC CONDUIT SHALL BE BURIED MINIMUM OF 24 INCHES IF NOT
INSTALLED UNDER CONCRETE OR ENCASED IN 3 INCH CONCRETE ENVELOPE.
FLEXIBLE METALLIC CONDUIT OR METAL-CLAD CABLE: MAY BE USED FOR
SHORT FINAL CONNECTIONS FOR INDOOR EQUIPMENT. PROVIDE INSULATED
COPPER BOND WIRE IN ALL FLEXIBLE RACEWAYS AND SIZED PER NEC-250.
LIQUiDTIGHT FLEXIBLE METALIC CONDUIT: SHALL BE USED OUTDOOR AND IN
MOIST LOCATIONS WITH LISTED TERMINATION FITTINGS.
YOSt'
ALL CONDUCTORS SHALL BE SOFT DRAWN ANNEALED COPPER HAVING
PURE COPPER CONDUCTIVITY OF NOT LESS THAN 98J5. UNIFORM IN
CROSS SECTION.
FREE FROM FLAWS. SCALES, AND OTHER IMPERFECTIONS.
CONDUCTORS IN CONDUIT:
•XHHW-2 OR THWN-2 INSULATION FOR ALL EXTERIOR FEEDERS IN
CONDUIT.
•THHN-2 INSULATION FOR ALL INDOOR BRANCH CIRCUITS IN CONDUIT.
•MINIUUM SIZE VWRE SHALL BE #14 AWG COPPER.
•NO WIRE MAY 8E DRAWN INTO CONDUIT UNTIL CONDUIT SYSTEM IS
COMPLETE. CONDUCTOR PULLING LUBRICANT SHALL BE USED TO
FACILITATE WIRE PULLING.
NONMETALLIC-SHEATHED CABLE:
NON-METALLIC SHEATHED CABLES SIZED PER NEC MAY PROVIDE ALL
WIRING CONNECTIONS FOR EQUIPMENT FURNISHED UNDER OTHER
SECTIONS OF THE SPECIFICATIONS
ALL WIRING SHALL BE TESTED UPON COMPLETION OF WORK. AND
ADJUSTMENTS MADE NECESSARY FOR SATISFACTORY OPERATION OF THE
SYSTEM.
WHERE SUBJECT TO PHYSICAL DAMAGE, CONDUCTORS SHALL BE
ADEQUATELY PROTECTED. WHEN THE WRING METHOD IS INSTALLED
THROUGH BORED HOLES
IN JOISTS, RAFTERS OR WOOD MEMBERS. HOLES SHALL BE BORED SO
THAT THE EDGE OF THE HOLE IS NOT LESS THAN 1-1/4" FROM THE
NEAREST EDGE OF THE WOOD MEMBER. WHERE THIS DISTANCE CANNOT
BE MAINTAINED. THE CABLE SHALL BE PROTECTED FROM PENETRATION
BY SCREWS OR NAILS BY A STEEL PLATE, AT LEAST 1/16' THICK, AND
OF APPROPRIATE LENGTH AND WIDTH INSTALLED TO COVER THE AREA OF
THE WIRING.
'GROUNDING CONDUCTORS:
ALL GROUND CONDUCTORS SHALL BE SIZED PER NEC 250 PER EACH
APPLICATION*
=M Protect SSaSffMS «">o«™ Susan Reynolds•K*rlVJJC7V.l TEU $02-345-900*
APPROVALS DAT£ PfiOjCCT
DRAWN
CHECKED
ENGINEER
AWK"S 2200 Camino Robledo
Carlsbad, CA 92009
M.G.R. - - 1 1
REV. - - SIZE
PROJECT I - A
00 NOT SCALE DRAWINGS SCALE
CODE INTENT NO. DWG NO. I
1
NA | | SHEET _ OF
GENERAL NOTES & SPECIFICATIONS (SHEET 2 OF 2)
SAFETY SWITCHES
SAFETY SWITCHES, SHALL BE HEAVY DUTY TYPE, 240 VOLT MINIMUM
WITH THE EXACT NUMBER OF POLES REQUIRED. ALL SAFETY SWITCHES
SHALL BE OF THE FUSIBLE TYPE. FUSES SHALL BE SIZED AS
RECOMMENDED BY EQUIPMENT MANUFACTURER. THE SWITCH SIZE SHALL
BE AS REQUIRED BY THE NEC AND AS INDICATED ON THE DRAWINGS
AND SIZED PER HORSEPOWER RATING. WHERE OUTSIDE THE BUILDING.
THE SWITCHES SHALL BE RAINTIGHT TYPE NEMA-3R.
FUSES
FUSES SHALL BE OF THE TYPE. SIZE AND RATING AS INDICATED ON
THE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ENGINEER ON RECORD FOR RESOLUTION.
GROUNDING
ELECTRICAL CONTRACTOR SHALL VERIFY PROPER GROUNDING
CONNECTIONS, GROUND CONDUCTORS AND INSTALL AS PER THE
GROUNDING DETAILS AS INDICATED !N THESE DRAWINGS. ALL EQUIPMENT
AND ENCLOSURES, AND THE COMPLETE CONDUIT SYSTEM SHALL BE
GROUNDED SECURELY IN ACCORDANCE WITH PERTINENT SECTIONS OF
NEC, ARTICLE 250, ALL ELECTRICALLY OPERATED EQUIPMENT SHALL BE
BONDED TO THE GROUNDING SYSTEM. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION.
FIELD NOTES
BRANCH PANELS
BRANCH PANEL60ARDS ARE EXISTING AND SHALL BE USED. BREAKER
TYPE SHALL BE MATCHED WITH THE EXISTING AND RATED AS SPECIFIED
ON THE DRAWINGS. TIE BARS TO FORM TWO-POLE BREAKERS WILL NOT
BE ACCEPTED. EACH PANEL SHALL BE PROVIDED WITH A TYPEWRITTEN
SHEET INSTALLED ON THE DOOR, WHICH IDENTIFY THE ASSIGNMENT OF
EACH BREAKER.
FINAL INSPECTION & TESTS
FURNISH ALL METERS, CABLE CONNECTIONS AND APPARATUS
NECESSARY FOR TESTING. TEST SYSTEM FOR SHORTS AND GROUNDS.
FAULTY WRING SHALL BE REMOVED AND REPLACED. ANY DEVICE,
APPARATUS OR FIXTURE INSTALLED SHOWING SUB-STANDARD
PERFORMANCE SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL
COST TO THE OWNER.
=M Project 4M S SECOND AVE.PHOENIX, AZ 85003
TEU 602-343-8006
APPROVALS
DRAWN
CHECKED
ENGINEER
M.G.R.
REV.
PROJECT # -
DO NOT SCALE DRAWINGS
PROJECT NAME-Susan Reynolds
2200 Camino Robledo
Carlsbad, CA 92009
SIZE
A
CODE INTENT NO.DWG NO.
SCALE NA | SHEET
REYNOLDS / SDR-0555
RESIDENTIAL LOAD CALCULATION
PANEL TYPE: GE
MAIN CB AMPS: 200
General Lighting and receptacle loads
NEC 2008- 220.83 (A)(1)1 'Square ft
Outside dimensions of home (exclude garage) 3500
Small appliance and laundry load
NEC 2008 - 220.83 (A)(2)
Small appliance
Laundry
Special Appliance Loads
NEC 2008 -220.83 (A) (3)
Dishwasher
Disposal
Microwave
Refrigerator
Trash Compactor
Clothes Washer
Force Air Unit
A/C Window Unit
A/c Unit
A/C Unit
Cooktop / Range
Clothes Dryer ( electric )
Water Heater
Heated Spa
Heat Pump
Pool Filter 1/2 hp
TOTAL:
Applying Demand Load
First VA at indicated %
Second VA at indicated %
Electric Vehicle Equipment
TOTAL LOADS
Applying Demand Load
TOTAL SERVICE ENTRANCE LOAD
I'VA/ckr
1500
1500
Phasel i:: Volts f
1 120
1 120
1 120
1 120
1 120
1 120
1 120
1 120
1 240
1 240
1 240
1 240
1 240
1 240
1 240
1 240
' ' r^vAiij-
8000
32560
7680
l^y-HI-
240
|;;VA/Sqft |
3
1 J*ckts ^|
2
1
r"!:<Ami»"Vyl
10
9.3
12
3.75
7.2
4.5
6.25
0
24
24
32
0
0
0
0
0
d
|,u:;:%Tni
100
40
100
n
\rnxm
I 119.6 I
VA |
10500
VA |
3000
1500
VA NOTES:
1200
1116
1440
450
864
540
750
0
5760
5760
7680
0
0
0
0
0
40560
VA |
8000
13024
....7680
28704|
VA | ,
28704]