Loading...
HomeMy WebLinkAbout2200 CAMINO ROBLEDO; ; CB111068; Permit05-23-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Cogeneration Permit Permit No:CB111068 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2200 CAMINO ROBLEDO CBAD COGEN Sub Type: 2552613600 Lot#: $0.00 Construction Type: Reference #: HIERS: 40AMP CIRCUIT? MENA 6- 50 RECEPT//W/SUB-MERTER EVG 0 NEW Applicant: SUNWEST ELECTRIC INC 3064 E MIRALOMA AV 92806 714630-8700 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: Owner: REYNOLDS PETER D&SUSAN H 2200 CAMINO ROBLEDO CARLSBAD CA 92009 ISSUED 05/20/2011 JMA 05/23/2011 05/23/2011 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee Total Fees: $22.00 Total $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $1.00 Payments To Date: PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Additional Fees TOTAL PERMIT FEES $22.00 Balance Due: $0.00 $20.00 $0.00 $0.00 $22.00 $0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE rat approval of your project includes the "Imposition" onees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 /2718/ 2719 Fax 760-802-8558 www.carfsbatica.gov Plan Check No . (_J&.\ I ( Est. Value Plan Ck. Deposit Date SWPPP JOB ADDRESS 2200 Camino Robledo #OFUMTS I«BEDROOMS * BATHROOMS (TENANT BUSINESS NWE CONSTRTYPE IOCC.GROUP DESCRIPTION OF WORK: Include Squan Feet o/A/foc(cd Area(s) Install 40A circuit and NEMA 6-50 receptacle for Electrical Vehicle Equipment EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YESQ» N(Q AIR CONDITIONING FIRE SPRINKLERS CONTACT NAME APPLICANT NAME Shaun Eastman ADDRESS ADDRESS 3064 E.Miraloma Ave. CITY STATE ZIP CITY Anaheim STATE CA ZIP 92806 PHONE FAX PHONE 714-678-0083 FAX 714-630-8740 EMAIL EMAIL seastman@sunwesteiect.com PROPERTY OWNER NAME Susan Reynoids CONTRACTOR BUS. NAME Sunwest Electric, Inc. ADDRESS 2200 Camino Robledo ADDRESS 3064 E. Mlraloma Ave. CITY Carlsbad STATE CA ZIP 92009 CITY Anaheim STATE CA zip 92806 PHONE 760-635-0558 FAX PHONE 714-60-8700 FAX 714-630-8740 EMAIL EMAIL seastman@sunwestelect.com ARCH/DESIGNER MIME & ADDRESS 511697 C10 cnvBuaucj 1216494 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its Issuance, also requires theapplicant (or such permit to file 3 signed statement that he fs licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of UieBusiness and Professions Code) or that he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than Hve hundred dollars (5500J). Workers' Compensation Declaration: I hereby eft.™ under penalty olpetfviy one o/l/ie totMng declarations:BI have and will maintain a certificate of consent to self-Insure for writers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. ! have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation Insurance carrier and policy number are: Insurance Co _Old Republic No.. TOs section need not be completed if the permit Is for one hundred dollars ($100) or less. LJ Certificate of Exemption; I certify that In the performance of the work for California. WARNING: Failure to secure workers' compensation coverage Is addition to the cost ol compensaUoj^damagw ^CONTRACTORSIGNATURE Expiration Dale. tot employ any person In any manner so as to become subject to the Workers' Compensation Laws of aa employer to criminal penalties and civil fines up to one hundred thousand dollars (S100,000), In attorney'sfees^ ^ / \ 0AGEKT DATE Q/Z^ IherebyaSm fasti em exempt from Contractor's L [ | I, as owner of the property or my employees with wages as Itielr sole compensation, wi do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Lew does not apply to an owner of property who builds or Improves Biereon. and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have Ihe burden of proving that he did not buSd or Improve for the purpose of safe). [71 I, as owner of the properly, am exclusively contracting with licensed contractors to consM the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) Ecensed pursuant to Ihe Contractor's License Law). [ [ I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed properly improvement I lYes | JNo 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed constacfion (include name address / phone / contractors' license number): A. I plan to provide portions of Ihe work, but I have hired Vie (Mowing person to coordinate, supervise and provide the major work [Include name I address / phone / contractors' license number): S. I will provide some of the work, but I have contacted (hied) the following persons to provide the work indicated (include name / address / phone / type of work): ,£f PROPERTY OWNER SIGNATURE [7JAGENT DATE Is the applicant or future building occupant required to submit a business ota acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25933 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I""! Yes LJNo Is the appfeant or tuturs tw'Minj occupant required to oMaln a permit (ram the air solution cofitroUMrtet or ajroualib management district? LjYes I Itio Is the fscSty to be constaictedwi'ttilfi 1,000 fe«t of tne outer boundary ol a school ste? I lYes flNo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there Is a construction lending agency for the performance of the work this permit Is Issued (Sec. 3097 (I) CM Code), Lender's Name n/a Lenders Address 1 hereby authorize representative of the CSyol Cartsbad to enterupon Bie above menfoned properVfwter^wipuixjsas. I ALSO AGREE TO SAVE, INDEWFY AND I€EP HARNESS THE CFTY OF CARLSBAD ASAJNST ALL UABILfTIES, JUDGMENTS. COSTS AND EXPENSES WHICH MM IN ANY WAY ACCRUE AGAINST SAIO CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA perrrit Is required for excavations over SO deep and demolition or WMtruct* of slructuresoverSslorfes in height EXPIRATION: Every pemfl issued by the Butding Official under tfca provlstansrfttife Code spl expire by MMon and become mi! and void if the building or roik authorized by such perrrit Is not cormenced within ITOd^fiomfoedateofsuchperrfteiflhebuMir^wvrorka^-,«__—-»-P^!SSSS=' , f~y^x*: ~ r r^ ^APPLICANTSSIGNATURE < "£s&—- -*^'*. / "\ '" DATE City of Carlsbad Bldg Inspection Request For: 06/16/2011 Permit* CB111068 Title: HIERS: 40AMP CIRCUIT? MENA 6- Description: 50 RECEPT//W/SUB-MERTER Inspector Assignment: 2200 CAMINO ROBLEDO Lot: 0 Type:COGEN Sub Type: EVG Job Address: Suite: Location: APPLICANT SUNWEST ELECTRIC INC Owner: REYNOLDS PETER D&SUSAN H Remarks: Phone: 7143157753 Inspector: Total Time: CD Description 34 Rough Electric 39 Final Electrical Act Comments Requested By: CARLOS Entered By: JANEAN Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments wm w -o55 O S< fi£n O5s gSS o 1 GENERAL NOTES & SPECIFICATIONS (SHEET 1 OF 2) WORK SPECIFIED HEREIN WORK UNDER THIS SPECIFICATION INCLUDES FURNISHING ALL MATERIAL. LABOR. EQUIPMENT, ETC., AND FINAL CONNECTION TO EQUIPMENT IN ORDER TO PROVIDE THE OWNER WITH A COMPLETE AND PROPERLY FUNCTIONAL ELECTRIC VEHICLE SUPPLY EQUIPMENT. IN GENERAL, THE WORK SHALL CONSIST OF BUT NOT BE LIMITED TO THE FOLLOWING: • FURNISH AND INSTALL ALL OF THE EQUIPMENT AND THE POWER SUPPLY FOR THE ELECTRIC VEHICLE SUPPLY EQUIPMENT, INCLUDING; CIRCUIT PROTECTION DEVICES AND BRANCH FEEDERS. • PRIOR TO INSTALLATION AND FINAL CONNECTION, VERIFY ELECTRICAL CHARACTERISTICS OF THE DISTRIBUTION SYSTEM AND LOCATION OF THE EVSE. • GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND ROOF TO MAINTAIN FIRE RATING AND WATERTIGHT INTEGRITY OF WALLS AND ROOF. GENERA! RFrXJIREMFNT?; THE CONTRACTOR WILL BE HELD TO HAVE THOROUGHLY REVIEWED GENERAL CONSTRUCTION DRAWINGS, EXAMINED THE SITE, PREMISES AND SATISFIED HIMSELF AS TO EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGED TO OPERATE OR WHICH WILL IN ANY MANNER AFFECT THE WORK UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. PROVIDE STANDARD PRODUCTS OF ESTABLISHED MANUFACTURERS REGULARLY ENGAGED 1N THE PRODUCTION OF SUCH EQUIPMENT. PROVIDE NEW MATERIAL. APPARATUS AND EQUIPMENT OF THE BEST PRACTICE OF THE ELECTRICAL TRADE AND BY SKILLED CRAFTSMEN. ALL EQUIPMENT SHALL BE LISTED BY UNDERWRITERS LABORATORIES. OR EQUIVALENT NRTL, FOR USE INTENDED. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL HARMONIZE HIS WORK SO THAT EACH PIECE OF EQUiPMENT WILL BE INSTALLED SO AS TO FUNCTION PROPERLY. COOPERATE WITH OWNER AND VERIFY ALL EQUIPMENT LOCATIONS. WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS OF STATE, COUNTY, MUNICIPAL AUTHORITIES. UTILITY COMPANY, N.E.C. AS SHOWN ON CONSTRUCTION DOCUMENTS. SEC CONSTRUCTION ORAWNGS FOR EQUIPMENT LOCATIONS. AND APPLICABLE ELEVATIONS AND DETAILS. ELECTRICAL CONTRACTOR TO VERIFY AND ACKNOWLEDGE ALL COOES AND REGULATIONS PERTAINING TO THIS PROJECT. REFER TO THE NATIONAL ELECTRIC CODE, ARTICLE 625 AND ALL OTHER APPLICABLE SECTIONS OF THE NEC. C.C&llUJJ. CONDUITS SHALL BE SIZED IN ACCORDANCE WtTH THE APPROPRIATE TABLE OF NEC. AND SHALL BE OF SUCH SIZE AND SO INSTALLED THAT CONDUCTORS MAY BE DRAWN IN WITHOUT INJURY OR STRAIN. CONDUIT SHALL BE SECURED TO PULL BOXES. SUPPORT BOXES. OR OUTLET BOXES WITH GALVANIZED LOCKNUTS AND BUSHINGS. ALL CONDUITS SHALL BE RUN CONCEALED PRINCIPALLY IN OVERHEAD AND WALL CONSTRUCTION. ALL CONDUIT THAT MUST BE EXPOSED SHALL BE RUN PARALLEL WITH LINES OF THE BUILDING, CHASES AND OPENINGS IN WALLS, PARTITIONS AND FLOORS SHALL BE PROVIDED FOR INSTALLATION OF CONDUIT; ALL CONCEALED WORK SHALL BE DONE SO AS TO MINIMIZE CUTTING AND PATCHING. ALL CONDUIT NOT EMBEDDED IN CONCRETE SHALL BE FIRMLY SECURED BY LISTED PIPE CLAMPS, HANGERS. ETC. ELECTRICAL METALLIC TUBING: USED FOR ALL WIRING EXCEPT IN OR UNDERCONCRETE, EARTH, FILL, OR GROUTED BLOCK WALLS. GALVANIZED STEEL CONDUIT: USED FOR ALL WIRING IN OR UNDERCONCRETE, EARTH. FIU. AND GROUTED WALLS. IN EARTH OR FILL. COAT WITH POLYETHYLENE TAPE, SPIRAL WRAPPED TO NOT LESS THAN 40MILS. NON-METALUC: LISTED, SCHEDULE 4D. PVC MAY BE USED FOR BRANCH FEEDER CIRCUITS IF RUN UNDER CONCRETE FLOOR. PROVIDE BONO WIRE PER NEC. PVC CONDUIT SHALL BE BURIED MINIMUM OF 24 INCHES IF NOT INSTALLED UNDER CONCRETE OR ENCASED IN 3 INCH CONCRETE ENVELOPE. FLEXIBLE METALLIC CONDUIT OR METAL-CLAD CABLE: MAY BE USED FOR SHORT FINAL CONNECTIONS FOR INDOOR EQUIPMENT. PROVIDE INSULATED COPPER BOND WIRE IN ALL FLEXIBLE RACEWAYS AND SIZED PER NEC-250. LIQUiDTIGHT FLEXIBLE METALIC CONDUIT: SHALL BE USED OUTDOOR AND IN MOIST LOCATIONS WITH LISTED TERMINATION FITTINGS. YOSt' ALL CONDUCTORS SHALL BE SOFT DRAWN ANNEALED COPPER HAVING PURE COPPER CONDUCTIVITY OF NOT LESS THAN 98J5. UNIFORM IN CROSS SECTION. FREE FROM FLAWS. SCALES, AND OTHER IMPERFECTIONS. CONDUCTORS IN CONDUIT: •XHHW-2 OR THWN-2 INSULATION FOR ALL EXTERIOR FEEDERS IN CONDUIT. •THHN-2 INSULATION FOR ALL INDOOR BRANCH CIRCUITS IN CONDUIT. •MINIUUM SIZE VWRE SHALL BE #14 AWG COPPER. •NO WIRE MAY 8E DRAWN INTO CONDUIT UNTIL CONDUIT SYSTEM IS COMPLETE. CONDUCTOR PULLING LUBRICANT SHALL BE USED TO FACILITATE WIRE PULLING. NONMETALLIC-SHEATHED CABLE: NON-METALLIC SHEATHED CABLES SIZED PER NEC MAY PROVIDE ALL WIRING CONNECTIONS FOR EQUIPMENT FURNISHED UNDER OTHER SECTIONS OF THE SPECIFICATIONS ALL WIRING SHALL BE TESTED UPON COMPLETION OF WORK. AND ADJUSTMENTS MADE NECESSARY FOR SATISFACTORY OPERATION OF THE SYSTEM. WHERE SUBJECT TO PHYSICAL DAMAGE, CONDUCTORS SHALL BE ADEQUATELY PROTECTED. WHEN THE WRING METHOD IS INSTALLED THROUGH BORED HOLES IN JOISTS, RAFTERS OR WOOD MEMBERS. HOLES SHALL BE BORED SO THAT THE EDGE OF THE HOLE IS NOT LESS THAN 1-1/4" FROM THE NEAREST EDGE OF THE WOOD MEMBER. WHERE THIS DISTANCE CANNOT BE MAINTAINED. THE CABLE SHALL BE PROTECTED FROM PENETRATION BY SCREWS OR NAILS BY A STEEL PLATE, AT LEAST 1/16' THICK, AND OF APPROPRIATE LENGTH AND WIDTH INSTALLED TO COVER THE AREA OF THE WIRING. 'GROUNDING CONDUCTORS: ALL GROUND CONDUCTORS SHALL BE SIZED PER NEC 250 PER EACH APPLICATION* =M Protect SSaSffMS «">o«™ Susan Reynolds•K*rlVJJC7V.l TEU $02-345-900* APPROVALS DAT£ PfiOjCCT DRAWN CHECKED ENGINEER AWK"S 2200 Camino Robledo Carlsbad, CA 92009 M.G.R. - - 1 1 REV. - - SIZE PROJECT I - A 00 NOT SCALE DRAWINGS SCALE CODE INTENT NO. DWG NO. I 1 NA | | SHEET _ OF GENERAL NOTES & SPECIFICATIONS (SHEET 2 OF 2) SAFETY SWITCHES SAFETY SWITCHES, SHALL BE HEAVY DUTY TYPE, 240 VOLT MINIMUM WITH THE EXACT NUMBER OF POLES REQUIRED. ALL SAFETY SWITCHES SHALL BE OF THE FUSIBLE TYPE. FUSES SHALL BE SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER. THE SWITCH SIZE SHALL BE AS REQUIRED BY THE NEC AND AS INDICATED ON THE DRAWINGS AND SIZED PER HORSEPOWER RATING. WHERE OUTSIDE THE BUILDING. THE SWITCHES SHALL BE RAINTIGHT TYPE NEMA-3R. FUSES FUSES SHALL BE OF THE TYPE. SIZE AND RATING AS INDICATED ON THE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION. GROUNDING ELECTRICAL CONTRACTOR SHALL VERIFY PROPER GROUNDING CONNECTIONS, GROUND CONDUCTORS AND INSTALL AS PER THE GROUNDING DETAILS AS INDICATED !N THESE DRAWINGS. ALL EQUIPMENT AND ENCLOSURES, AND THE COMPLETE CONDUIT SYSTEM SHALL BE GROUNDED SECURELY IN ACCORDANCE WITH PERTINENT SECTIONS OF NEC, ARTICLE 250, ALL ELECTRICALLY OPERATED EQUIPMENT SHALL BE BONDED TO THE GROUNDING SYSTEM. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION. FIELD NOTES BRANCH PANELS BRANCH PANEL60ARDS ARE EXISTING AND SHALL BE USED. BREAKER TYPE SHALL BE MATCHED WITH THE EXISTING AND RATED AS SPECIFIED ON THE DRAWINGS. TIE BARS TO FORM TWO-POLE BREAKERS WILL NOT BE ACCEPTED. EACH PANEL SHALL BE PROVIDED WITH A TYPEWRITTEN SHEET INSTALLED ON THE DOOR, WHICH IDENTIFY THE ASSIGNMENT OF EACH BREAKER. FINAL INSPECTION & TESTS FURNISH ALL METERS, CABLE CONNECTIONS AND APPARATUS NECESSARY FOR TESTING. TEST SYSTEM FOR SHORTS AND GROUNDS. FAULTY WRING SHALL BE REMOVED AND REPLACED. ANY DEVICE, APPARATUS OR FIXTURE INSTALLED SHOWING SUB-STANDARD PERFORMANCE SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. =M Project 4M S SECOND AVE.PHOENIX, AZ 85003 TEU 602-343-8006 APPROVALS DRAWN CHECKED ENGINEER M.G.R. REV. PROJECT # - DO NOT SCALE DRAWINGS PROJECT NAME-Susan Reynolds 2200 Camino Robledo Carlsbad, CA 92009 SIZE A CODE INTENT NO.DWG NO. SCALE NA | SHEET REYNOLDS / SDR-0555 RESIDENTIAL LOAD CALCULATION PANEL TYPE: GE MAIN CB AMPS: 200 General Lighting and receptacle loads NEC 2008- 220.83 (A)(1)1 'Square ft Outside dimensions of home (exclude garage) 3500 Small appliance and laundry load NEC 2008 - 220.83 (A)(2) Small appliance Laundry Special Appliance Loads NEC 2008 -220.83 (A) (3) Dishwasher Disposal Microwave Refrigerator Trash Compactor Clothes Washer Force Air Unit A/C Window Unit A/c Unit A/C Unit Cooktop / Range Clothes Dryer ( electric ) Water Heater Heated Spa Heat Pump Pool Filter 1/2 hp TOTAL: Applying Demand Load First VA at indicated % Second VA at indicated % Electric Vehicle Equipment TOTAL LOADS Applying Demand Load TOTAL SERVICE ENTRANCE LOAD I'VA/ckr 1500 1500 Phasel i:: Volts f 1 120 1 120 1 120 1 120 1 120 1 120 1 120 1 120 1 240 1 240 1 240 1 240 1 240 1 240 1 240 1 240 ' ' r^vAiij- 8000 32560 7680 l^y-HI- 240 |;;VA/Sqft | 3 1 J*ckts ^| 2 1 r"!:<Ami»"Vyl 10 9.3 12 3.75 7.2 4.5 6.25 0 24 24 32 0 0 0 0 0 d |,u:;:%Tni 100 40 100 n \rnxm I 119.6 I VA | 10500 VA | 3000 1500 VA NOTES: 1200 1116 1440 450 864 540 750 0 5760 5760 7680 0 0 0 0 0 40560 VA | 8000 13024 ....7680 28704| VA | , 28704]