Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; CB044184; Permit1 ,, . City of Carlsbad ,, \ 02-08-2005 \ 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB044184 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: 2200 FARADAY AV CBAD Tl Sub Type: COMM Lot#: 0 Status: Valuation: Occupancy Group: 2121203400 $1,262,785.00 Construction Type: NEW Reference #: Applied: Entered By: Project Title: ROCK STAR SAN DIEGO 40735 SF Tl OFFICE TO OFFICE Applicant: ROEL CONSTRUCTION CO INC 3366 KURTZ ST SAN DIEGO, CA 92110 619-297-4156 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $3,613.44 $0.00 $2,348.74 $0.00 $0.00 $265.18 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Plan Approved: Issued: Inspect Area: Plan Check#: Owner: E QB P-1 LL C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA 92037 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF PFF (CFO Fund) License Tax License Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES ISSUED 11/18/2004 SB 02/08/2005 02/08/2005 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $160.00 $210.00 $77.00 $0.00 $0.00 $0.00 $0.00 $6,674.36 Total Fees: $6,674.36 Total Payments To Date: $2,348.00 Balance Due: $4,326.36 Inspector: FINAL APPROVAL -- 0002 01 CG~::u /:" ---( ( -tJ'.S Date: ___,_..,.{!________ Clearance: _____ _ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.'' You have 90 days from the date this permit was issued to protest imposition of these lees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been niven a NOTICE similar to this or as to which the statute of limitations has oreviouslv otherwise exoired. 02 4326-36 ., t. t' CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Legal Description Lot No. 582i4iaUiefa8J 04 OOflii1 (blf unitsO2 Assessor's Parcel# Existing Use S .-1::' n Yoi1 ~v::> ,,. ~ Prop~Use # of Bathrooms (4, ~-OWNER ·--~ ~-.....-±::;;;-~ @:, ?\l:,ergdo -J\' I -:,fC. 306 Name Address City [5. CONTRACTOR· COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by an applicant for a permit subjects the applicant to a civil penalty of not mo e than ve hundred dollars $500)) .. D ,._._,,..,,V"\ "?j ltLP U . Cf1J.lo 0iq. 2Ci7~ 416<.p Name Address License Class ___________ _ 11 o;1si T6!1.p.e~i Designer Name Address City State/Zip Telephone# State License# _______ _ 6. WORKER'S COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which is permit is issued. My worker's compensatio._o.!As.11rance carrier and policY. umber are: ('"); ':7 z / Insurance Company -./-,... Policy No. ¥,-0-__ r Expiration Date. ___ ~-.:=--=cF--""'"'-=:.._- (THIS SECTION NEE OT BE C MPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to o e hundred thousand ollars($100,000), in addition to t t of SIGNATURE DATE . v-owNER-su,LDE r RATIO I hereby affirm that I am exe'mpt from the· ontractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to ari owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I {have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name I address/ phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ /ontractors license number):---------------------------------------------- 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address / phone number I type of work): PROPERTY OWNER SIGNATURE ___________________________ DATE ___________ _ WHITE: File YELLOW: Applicant PINK: Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 ~IETEfITTSSEC'i'for'fFOR NON-RESIDENTIAL BUILDING PERMITSONL Y l Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES' NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES X NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES ~O IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. IB. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME___________________ LENDER'S ADDRESS ___________________ _ fg. -APPLICANT CER'l"IFICATION ::I I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after ::2:::::::~4 ~ li DATE_\_\_/_\_l __ ( ... 0_·1 ________ _ WHITE: File YELLOW: Applicant PINK: Finance CilY of Carlsbad · Final Building Inspection ~ Dept: Building Engineering Planning CMWD St Lite 'Le,/ Plan Check#: ~Date: 06/20/2005 Permit#: Project Name: CB044184 ROCK STAR SAN DIEGO 40735 SF Tl OFFICE TO OFFICE Address: 2200 FARADAY AV Contact Person: RICK Phone: 6195209120 Sewer Dist: CA Water Dist: CA Permit Type: Tl Sub Type: COMM Lot: 0 .......................................................................................................................................................... Blny~.pectedo/4= . Date / ; -~~· ~ Inspected: 1(1/65--: TJ I Inspected · Date Approve~ Disapproved: __ By: __________ Inspected:----~ Approved: __ Disapproved: __ Inspected Date By: Inspected: _____ Approved: __ Disapproved: __ •••••••••••••••11111a1111111••••••••••••••••••1111111111••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••11111111111111111111111 Comments: ------------------------------ Inspection List Permit#: CB044184 Type: Tl COMM ROCK ST AR SAN DIEGO 40735 SF Tl OFFICE TO OFFICE Date Inspection Item Inspector Act Comments 09/21/2005 89 Final Combo RB AP 06/23/2005 29 Final Plumbing RB AP 06/23/2005 39 Final Electrical RB AP 06/23/2005 49 Final Mechanical RB AP 06/23/2005 89 Final Combo RB PA TEMP COFO -COMPLETE ADA RAMPS @ WEST SIDE OF BLDG. 06/20/2005 84 Rough Combo RB AP ON ROOF INSPECT 06/20/2005 89 Final Combo RB co SEE NOTICE 06/16/2005 84 Rough Combo RB co ROOF INSP. SEE NOTICE ATTACHED 06/14/2005 34 Rough Electric RB AP PANELS OK 05/31/2005 17 Interior Lath/Drywall RB AP completed 05/25/2005 14 Frame/Steel/Bolting/Weldin RB AP COMPLETED 05/25/2005 14 Frame/Steel/Bolting/Weldin RB AP T BAR SYSTEM COMPLETED 05/25/2005 24 Rough/Topout RB AP 05/25/2005 34 Rough Electric RB AP 05/25/2005 44 Rough/Ducts/Dampers RB AP 05/19/2005 12 Steel/Bond Beam PS AP FLR PATCH SIGNED DETAILS 05/19/2005 14 F rame/Steel/Bolting/W el din PS AP EQUIP PADS ROOF SIGNED DETAILS 05/18/2005 84 Rough Combo RB PA T-BAR -OK EXCEPT EDIT RMS & EXIT SIGN @ LOUNGE 05/16/2005 11 Ftg/Foundation/Piers RB WC 05/16/2005 14 Frame/Steel/Bolting/Weldin RB PA RAISED FLR @ TEAM B -SEE PLAN 05/16/2005 31 Underground/Conduit-Wirin RB PA RAISED FLR @ TEAM B -SEE PLAN 05/13/2005 11 Ftg/Foundation/Piers RB WC 05/13/2005 14 F rame/Steel/Bolting/W el din RB PA RAISED FLR SYSTEM 05/12/2005 14 Frame/Steel/Bolting/Weldin RB PA RAISED FLR AT TEAM A SEE PLAN 05/12/2005 31 Underground/Conduit-Wirin RB PA RAISED FLR AT TEAM A SEE PLAN 05/05/2005 84 Rough Combo RB PA ZONE 2 T-BAR SYSTEM OK 05/04/2005 14 F rame/Steel/Bolting/W el din RB AP HARD LIDS PHASE 3 05/04/2005 84 Rough Combo RB co PHASE 2 -REWALK 05/04/2005 84 Rough Combo RB AP T-BAR SYSTEM PHASE 1 05/02/2005 14 Frame/Steel/Bolting/Weldin RB co MISSING STRONG BACKS ON HARD LIDS 04/29/2005 84 Rough Combo RB PA @ ZONE 1 -SEE NOTICE 04/28/2005 17 Interior Lath/Drywall RB PA OK@ HARD LIDS, FURRED WALLS & RM274&275 04/26/2005 14 Frame/Steel/Bolting/Weldin RB AP @ SOFT LINER AREAS 04/26/2005 14 Frame/Steel/Bolting/W.eldin RB AP @ HARD LIDS & SOFFITS 04/26/2005 34 Rough Electric RB AP 04/25/2005 14 Frame/Steel/Bolting/Weldin RB PA WALLS@ WEST EDIT RMS 04/25/2005 17 Interior Lath/Drywall RB PA OK ABOVE LIDS @ EAST EDIT RMS. 04/25/2005 18 Exterior Lath/Drywall RB WC 04/18/2005 17 Interior Lath/Drywall RB PA ok @ rstrm, tunnel & zone 3 except edit suite, demising wall ok 04/14/2005 14 Frame/Steel/Bolting/Weldin RB PA OK AT RESTROOMS 04/14/2005 24 Rough/Topout RB PA Friday, October 07, 2005 Page 1 of 2 1 04/14/2005 34 Rough Electric RB PA MISSING EXHAUST FANS 04/14/2005 44 Rough/Ducts/Dampers RB PA MISSING EXHAUST FANS 04/12/2005 17 Interior Lath/Drywall RB PA D.W.@ ZONE 2 WAL.LS OK 04/07/2005 14 F rame/Steel/Bolting/W el din RB PA WALLS @ ZONE 3 04/07/2005 14 Frame/Steel/Bolting/Weldin RB PA HARD LID @ TUNNELS OK RB 04/07/2005 17 Interior Lath/Drywall RB PA OK@ ZONE 1 04/07/2005 24 Rough/Topout RB PA TUNNELS & ZONES 1 & 2, 3 04/07/2005 34 Rough Electric RB PA @ ZONE 3 WALLS 04/04/2005 14 Frame/Steel/Bolting/Weldin RB PA WALLS @ ZONE 2 OK 04/04/2005 17 Interior Lath/Drywall RB PA ZONE 2 -ABOVE HARD LID @ RSTRMS 04/04/2005 24 Rough/Topout RB PA 1 ST FLR UNDRG TO POINT OF CONNECTION 04/04/2005 34 Rough Electric RB PA WALLS @ ZONE 2 OK 03/31/2005 14 Frame/Steel/Bolting/Weldin RB PA OK@ ZONE 1 03/31/2005 24 Rough/Topout RB PA Q3/31 /2005 34 Rough Electric RB PA 03/03/2005 14 Frame/Steel/Bolting/Weldin RB co STOP -RESUBMIT AS BUil TS 03/03/2005 24 Rough/Topout RB co 03/03/2005 34 Rough Electric RB co 03/02/2005 14 Frame/Steel/Bolting/Weldin RB co 03/02/2005 24 Rough/Topout PA PA ok@ zone 1 03/02/2005 34 Rough Electric PA co 03/02/2005 44 Rough/Ducts/Dampers PA WC Friday, October 07, 2005 Page 2 of 2 City of Carlsbad Bldg Inspection Request For: 09/21/2005 Permit# CB044184 Title: ROCK STAR SAN DIEGO 40735 SF Description: Tl OFFICE TO OFFICE Inspector Assignment: RB Type: Tl Job Address: Sub Type: COMM Suite: Location: 2200 FARADAY AV Lot 0 APPLICANT ROEL CONSTRUCTION CO INC Owner: E QB P-1 LL C Remarks: Total Time: Phone: 6192472669 Inspector: ----- Requested By: DAVE Entered By: CHRISTINE CD Description Act Comment ruo 19 Final Structural 1-29 Final Plumbing 39 Final Electrical 49 Final Mechanical -; Associated PCRs/CVs PCR05034 ISSUED PCR05069 ISSUED ROCK STAR SAN DIEGO; ADD ELEC & MECH TO SOUND STUDIO/ OFFICES ROCKSTAR SECOND FLOOR REVISE; PCR05080 ISSUED ROCKSTAR RAISED COMPUTER; ACCESS FLOOR Inspection History Date Description 06/23/2005 29 Final Plumbing 06/23/2005 39 Final Electrical 06/23/2005 49 Final Mechanical 06/23/2005 89 Final Combo 06/20/2005 84 Rough Combo 06/20/2005 89 Final Combo· 06/16/2005 84 Rough Combo 06/14/2005 34 Rough Electric 05/31/2005 17 Interior Lath/Drywall 05/25/2005 14 Frame/Steel/Bolting/Welding 05/25/2005 14 Frame/Steel/Bolting/Welding 05/25/2005 24 Rough/Topout 05/25/2005 34 Rough Electric 05/25/2005 44 Roui:ih/Ducts/Dampers Act AP AP AP PA AP co co AP AP AP AP AP AP AP lnsp RB RB RB RB RB RB RB RB RB RB RB RB RB RB Comments TEMP COFO -COMPLETE ADA RAMPS @ WEST SIDE OF BLDG. ON ROOF INSPECT SEE NOTICE ROOF INSP. SEE NOTICE ATTACHED PANELS OK completed T BAR SYSTEM COMPLETED ,. -"' City of Carlsbad Bldg. Inspection Request For: 06/20/2005 Permit# CB044184 Title: ROCK STAR SAN DIEGO 40735 SF Description: Tl OFFICE TO OFFICE Inspector Assignment: RB --- Type: Tl Job Address: Sub Type: COMM Suite: Location: 2200 FARADAY AV Lot 0 APPLICANT ROEL CONSTRUCTION CO INC Owner: E QB P-1 LL C Remarks: Total Time: Phone: 6195209120 Inspector: ----- Requested By: RICK Entered By: CHRISTINE CD Description Act Comment 19 Final Structural C,-fj $~ ~Le__ 29 Final Plumbing 39 Final Electrical 49 Final Mechanical p Jhf-_______ hL_~~~~-~-·-'-~-n~S-A ______ _ 7 Associated PCRs/CVs PCR05034 ISSUED PCR05069 ISSUED ROCK STAR SAN DIEGO; ADD ELEC & MECH TO SOUND STUDIO/ OFFICES ROCKSTAR SECOND FLOOR REVISE; PCR05080 ISSUED ROCKSTAR RAISED COMPUTER; ACCESS FLOOR Inspection History Date Description 06/16/2005 84 Rough·Combo 06/14/2005 34 Rough Electric 05/31/2005 17 Interior Lath/Drywall 05/25/2005 14 Frame/Steel/Bolting/Welding 05/25/2005 14 Frame/Steel/Bolting/Welding 05/25/2005 24 Rough/Topout 05/25/2005 34 Rough Electric 05/25/2005 44 Rough/Ducts/Dampers 05/19/2005 12 Steel/Bond Beam 05/19/2005 14 Frame/Steel/Bolting/Welding 05/18/2005 84 Rough Combo 05/16/2005 11 Ftg/Foundation/Piers 05/16/2005 14 Frame/Steel/Bolting/Welding 05/16/2005 3"1 Underground/Conduit-Wiring Act co AP AP AP AP AP AP AP AP AP PA WC PA PA lnsp RB RB RB RB RB RB RB RB PS PS RB RB RB RB Comments ROOF INSP. SEE NOTICE ATTACHED PANELS OK completed T BAR SYSTEM COMPLETED FLR PATCH SIGNED DETAILS EQUIP PADS ROOF SIGNED DETAILS T-BAR • OK EXCEPT EDIT RMS & EXIT SIGN @ LOUNGE RAISED FLR @ TEAM B -SEE PLAN City of Carlsbad Bldg Inspection Request For: 05/19/2005 Permit# CB044184 Inspector Assignment: RB Title: ROCK STAR SAN DIEGO 40735 SF Description: Tl OFFICE TO OFFICE --- Type:TI Job Address: Sub Type: COMM 2200 FARADAY AV Phone: 6195209120 Suite: Lot 0 Location: Inspector: APPLICANT ROEL CONSTRUCTION CO INC Owner: E Q 8 P-1 L L C Remarks: Total Time: CD 12 14 Description Steel/Bond Beam Frame/Steel/Bolting/Welding Requested By: RICK Entered By: CHRISTINE Associated PCRs/CVs PCR05034 ISSUED PCR05069 ISSUED ROCK STAR SAN DIEGO; ADD ELEC & MECH TO SOUND STUDIO/ OFFICES ROCKSTAR SECOND FLOOR REVISE; PCR05080 ISSUED ROCKSTAR RAISED COMPUTER; ACCESS FLOOR Date 05/18/2005 05/16/2005 05/16/2005 05/16/2005 05/13/2005 05/13/2005 05/12/2005 05/12/2005 05/05/2005 05/04/2005 05/04/2005 05/04/2005 05/02/2005 04/29/2005 04/28/2005 04/26/2005 04/26/2005 04/26/2005 Inspection History Description 84 Rough Combo 11 Ftg/Foundation/Piers 14 Frame/Steel/Bolting/Welding 31 Underground/Conduit-Wiring 11 Ftg/Foundation/Piers 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 31 Underground/Conduit-Wiring 84 Rough Combo 14 Frame/Steel/Bolting/Welding 84 Rough Combo 84 Rough Combo 14 Frame/Steel/Bolting/Welding 84 Rough Combo 17 Interior Lath/Drywall 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 34 Rough Electric Act lnsp Comments PA RB T-BAR -OK EXCEPT EDIT RMS & EXIT SIGN @ LOUNGE WC RB PA RB RAISED FLR @ TEAM B -SEE PLAN PA RB WC RB PA RB RAISED FLR SYSTEM PA RB RAISED FLR AT TEAM A SEE PLAN PA RB RAISED FLR AT TEAM A SEE PLAN PA RB ZONE 2 T-BAR SYSTEM OK AP RB HARD LIDS PHASE 3 CO RB PHASE 2 -REWALK AP RB T-BAR SYSTEM PHASE 1 CO RB MISSING STRONG BACKS ON HARD LIDS PA RB ~ ZONE 1 -SEE NOTICE PA RB OK@ HARD LIDS, FURRED WALLS & RM 274 & 275 AP RB @ HARD LIDS & SOFFITS AP RB @ SOFT LINER AREAS AP RB City of Carlsbad Bldg Inspection Request For: 05/04/2005 Permit# CB044184 Inspector Assignment: RB Title: ROCK STAR SAN DIEGO 40735 SF Description: Tl OFFICE TO OFFICE Sub Type: COMM --- Type: Tl Job Address: Phone: 6195209120 Suite: Location: 2200 FARADAY AV Lot 0 APPLICANT ROEL CONSTRUCTION CO INC Owner: E QB P-1 LL C Remarks: Total Time: Inspector: ----- Requested Sy: RICK Entered By: JANEAN CD 14 Description Frame/Steel/Bolting/Welding Act Comm/4 ~ 0~ 24 34 Rough/Topout Rough Electric 44 Rough/Ducts/Dampers 4 ~ &1:/ i,~ Phag~ 5 -S=:l,-,-------/f-(?_--+-Y.~-=,&~q~/-S.-C/~r-~~~½<-1-+-'-'~~~¼t-s.4---=--/--- r Associated PCRs/CVs PCR05034 ISSUED ROCK STAR SAN DIEGO; ADD ELEC & MECH TO SOUND STUDIO/ OFFICES PCR05069 PENDING ROCKSTAR SECOND FLOOR REVISE; PCR05080 PENDING ROCKSTAR RAISED COMPUTER; ACCESS FLOOR Inspection History Date Description Act lnsp Comments 05/02/2005 14 Frame/Steel/Bolting/Welding co RB MISSING STRONG BACKS ON HARD LIDS 04/29/2005 84 Rough Combo PA RB @ ZONE 1 -SEE NOTICE 04/28/2005 17 Interior Lath/Drywall PA RB OK@ HARD LIDS, FURRED WALLS & RM 274 & 275 04/26/2005 14 Frame/Steel/Bolting/Welding AP RB @ HARD LIDS & SOFFITS 04/26/2005 14 Frame/Steel/Bolting/Welding AP RB @ SOFT LINER AREAS 04/26/2005 34 Rough Electric AP RB 04/25/2005 14 Frame/Steel/Bolting/Welding PA RB WALLS @ WEST EDIT RMS 04/25/2005 17 Interior Lath/Drywall PA RB OK ABOVE LIDS @ EAST EDIT RMS. 04/25/2005 18 Exterior Lath/Drywall WC RB 04/18/2005 17 Interior Lath/Drywall PA RB ok @ rstrm, tunnel & zone 3 except edit suite, demising wall ok 04/14/2005 14 Frame/Steel/Bolting/Welding PA RB OK AT RESTROOMS 04/14/2005 24 Rough/Topout PA RB 04/14/2005 34 Rough Electric PA RB MISSING EXHAUST FANS 04/14/2005 44 Rough/Ducts/Dampers PA RB City of Carlsbad Bldg Inspection Request For: 04/07/2005 Permit# CB044184 Inspector Assignment: RB --- Title: ROCK STAR SAN DIEGO 40735 SF Description: Tl OFFICE TO OFFICE Type: Tl Job Address: Sub Type: COMM 2200 FARAOAY AV Phone: 6195209120 Suite: Lot 0 Location: APPLICANT ROEL CONSTRUCTION CO INC Owner: E QB P-1 LL C Remarks: Total Time: Description Act Comment Inspector: Requested By: RICK Entered By: JANEAN Frame/Steel/Bolting/Welding et_ ~(~ @ .z,~ ..3 \ CD 14 24 34 Rough/Topout · jJ /J ~ r fA. .14 nf!h l ;z C/Yl-t1-.s. 1£-d-,3 Z J Rough Electric fl 4-~ @ ?-i;iyz L--. .3 ~ 44 Rough/Ducts/Dampers ~------1;: _t:7__,~'-=-c-'-!!:~~-;~, ~---=----@--===---~,__I u_rt_.#_~-~-a-~~c-~~ 2£3 . , r Associated PCRs/CVs PCR05034 ISSUED ROCK STAR·SAN DIEGO; ADD ELEC & MECH TO SOUND STUDIO/ OFFICES lns12ection Histo[Y Date Description Act lnsp Comments 04/04/2005 14 Frame/Steel/Bolting/Welding PA RB WALLS @ ZONE 2 OK 04/04/2005 17 Interior Lath/Drywall PA RB ZONE 2 -ABOVE HARD LID @ RSTRMS 04/04/2005 24 Rough/Topout PA RB 1ST FLA UNDRG TO POINT OF CONNECTION 04/04/2005 34 Rough Electric PA RB WALLS@ ZONE 2 OK 03/31/2005 14 Frame/Steel/Bolting/Welding PA RB OK@ ZONE 1 03/31/2005 24 Rough/Topout PA RB 03/31/2005 34 Rough Electric PA RB 03/03/2005 14 Frame/Steel/Bolting/Welding co RB STOP -RESUBMIT AS BUil TS 03/03/2005 24 Rough/Topout co RB 03/03/2005 34 Rough Electric co RB 03/02/2005 14 Frame/Steel/Bolting/Welding co RB 03/02/2005 24 Rough/Topout PA PA ok@ zone 1 03/02/2005 34 Rough Electric co PA 03/02/2005 44 Rough/Ducts/Dampers WC PA ASCINO INSPECTION SERVICES 2929 Fire Mo1:1ntain Dr. Suite #57 Oceanside. CA 92504 DEPT. OF BLDG. & SAFETY Cell (714) 404-7413 FAX (760) 722-0985 CITYOF (:q,t;JJ~cl COUNTYOF 5k"-o~\r SPECIAL INSPECTION REPORT Building Peimit No. C.d <J C/~ / f" 1./ Job No. f' ~ Date ~ J--2 Y--tJ y' · 7:1" c. I<" -/' z.2-0 o ~/'-~ Job Identification/ Address ----'-r_-, __ ,...,.,.._ __ .....__-__ '.,,,,....-----'---------,,......_-~ ____ Cl.. ___ '"'~------- General Contractor, Address _____ ..,..o_,_.,e ____ l __ · _C_0 _~ ___ J ___ //_/'_"""__,,C .... -_1_, __ c:J ___ 1 "------------- Sub-Contractor I Address _______ 74-:--:i------..=----------1,------------- Structural Engineer/ Address ---------_,~,.__e._. __ 6_--,.,_-r-£_l'_Y/ ____ ~ _____ e_r_l_~-,,rq __________ _ 7 y TYPE OF WORK: REINFORCED CONCRETE '« MASONRY PRESTRESSED CONCRETE_ WELDING_ WELDER RECEIPT NUMBER WELDER DATE OF INSPECTION DESCRIPTION OF WOR,K INSPECTED: HOURS ~-O.T. SAMPLES Grout Mortar Concrete Block Prisms HI-TENSILE BOLTING_ GYPSUM CONCRETE_ RECEIPT NUMBER TIMEOUT Density All inspections based on a minimum of 4 hours & over 4 hours -8 hour minimum. In addition, over 8 hours and Saturday will be billed at time and a half. ATl'OB,NEY'S FEES -If any action at law or in equity is brought to enforce or interpret the terms of this Contract, the prevailing party shall be entitled to reasonable attorney's fees, costs and necessary disbursements in addition to any other relief to which such party may be entitled. (\ /) SPECIAL INSPECTION REPOR/J _/7 Inspector's Nipµe: ~ lEJCflc O Inspector's Signature: ~ ~ ....._ I.D. No. & OH fl C has been filed and it states that the above work to the bestofhis/her knowledge complies with the provisions of the Unifonn Building Code and meets Approved Plans and Specification. J'C6'o· 16' :rl"a.l"O'l'/r ~ n Respectfully Submitted Approved by: ~\J~~ c By _____________ _ tHiz cn:v of sAN ou~eo ,').fiti'I . -·· . rtl'l!(Sl·OfVlOJll{ r,!fiHO!ll'.ll!D EOR ~t>EdN:INS~Ectti:IN- DANIEL CASCINO STRUCTURAL STEEL & WELDING SPECIAL INSPECTOR The individual named hereon is CERTIFIED in the category shown, having been so certified pursuant to successful comp!etlon of the prescribed written examination. •• h~ .f>l'\f\""1- ~ "' -,;I. I . •• DANIEL CASCINO STRUCTURAL STEEL & WELDING SPECIAL INSPECTOR. The Individual named hereon Is CERTIFIED In the category shown, having been so certified pursuant to successful completion of the prescribed written examination. Expiration date: April 21, 200 No. 5103641-85 \ .. _ ,. -·? ' r...,._ , ·l . .. . ·1 Not valfd unless sl e by ceitlfkate hci@eb IP : ICC certlllcatlon attE:.Sts to com~etenrkn~wledge_ of codes and standards. :/._ -. •·' CASCINO INSPECTION SERVICES 2929 Fire Mountain Dr. Suite #57 Oceanside, CA 92504 (714) 404-7413 FAX (760) 722-0985 SPECIAL INSPECTION REPORT Job No. -t:/ 77 'i(J_ _Job Identification/ Ad_dr..;;:es;:...:s=--~--'-r':l---''--;--0~ / L Z O 0 General Contractor/ Address L O //I @vr c--rf d '1 Sub-Contractor/ Address ~ ~ / .1---A -' Structural Engineer/ Address / / o,ee -f" J-t t; I J-1 (? e / I M 9 TYPE OF WORK: REINFORtED CONCREti_ MA§ONRY PRESTRESSED CONCRETE WELDING _k(__ DEPT. OF BLDG. & SAFETY c1TvoF{?/ Is,~</ ~ { \. COUNTY OF ~~V\ Ui er, CJ J a t-/~/i -Date ·1 ..,. v J -~,,r~ c/4' HI-TENSILE BOLTING GYPSUM CONCRETE WELDER RECEIPT NUMBER WELDER RECEIPT NUMBER r o c es J DATE OF INSPECTION HOURS Date Re. O.T. TIME IN TIMEOUT SAMPLES Grout Mortar Concrete Block Prisms Densit All inspections based on a minimum of 4 hours & over 4 hours -8 hour minimu~. In addition, over 8 hours and Saturday will be billed at time and a half. · ATTORNEY'S FEES -If any action at law or in equity is brought to enforce or interpret the terms of this Contract, the prevailing party shall be entitled to reasonable attorney's fees, costs and necessary disbursements in addition to any other relief to which such party may be entitled. · C' SPECIAL INSPECTION REPOR½ /' Inspector's Na,rp.e: Va..\,,\ ~' C J ;,1 a Inspector's Signature: A;; a c""'~ = I.D. No. ~J) --ii 1. has been filed and it states that the above work to the best of his/her knowledge complies with the provisions of the Uniform Building Code and meets Approved Plans and Speci cirtio)i. '-Re lf~tfully Submitte Approved by: .,,,.~,.~-1 6.,/4< c/-O'Yl C By !,!'t ~&,,,~-~-:-::=;;:-====----====------~ Project Superintendent· \ ,.."+,--,..; ·:t~;S~!NO w'sPECT!ONSriitJ.-;;Es DEPT. OF BLDG. & SAFETYrl 2929 Fire Mountain Dr. Suite #57 . ./ L . Oceanside, ·CA 92504 CITY OF · . ~/' / J .tl~ ~ (714) 404--7413 ------...,J,......... COUNTY OF s:~\.-\ t € <; U FAX ('l60) 722-0985 SPECIAL INSPECTION REPOR',f V Building Pennit No. C. J1'0<{_l//.,,~'L J~ z:/ 7/ fr} ; _ Date C) J., / ;t: () r jrobldentification/Address · ~£k S, 7(.'J{,~ · 22. Q O . ., ?"~;.~ ckv General Contractor; Address k o.e / . . Lo14 m,,,,,, :0/ d "1 / ) Sub-Contractor/ Address ___,..-~.,---c=-F,.-=-'""b'--, ~(;_· =-0-~,,....m_· _,__t'.'.=· '--'~-'--'/_·___,,__ _______________ _ Structural Engineer/ Address' ·,M!?e ' ~ t7l l'l. e e, I t,,1; t? TYPE OF WORK: REINFORtED CONCREtl_., _ MKs~NRY HI-TENSILE BOLTING PRESTRESSED CONCRETE __ . -WELDING IL GYPSUM CONCRETE .. WELDER RECEIPT NUMBER WELDER RECEIPT NUMBER . '. ~tJfV\ S<e.V\di1'Qre. Vroc e.s-1 ~/Vl/!),W V/ E"-:7?JI fr .!f/e;-r:- ,,. '• DATE OF INSPECTION _.,.....,, r, . J_ DESCRIPTION OF'WORK INSPECTED: o-r~/~ t1, -~~I, l '<r r<11 ~@ c UJJf.ti1.~/ T ;,,: ~ k< _ 1n~.Jz,.e c I o Pl 4 ...p .. -%',.6e .J-le ,e. { ~ rk:J~'y $JI;~ h &-1rn~c ... LAt-8e~~-p ~--L,..t~-€ .,, 7 --ll I/·. .,,.-, ;,.JR1"TI .. i -~) .. <' ' ..._..... "-tky/,;,-/; r. Wildr ru11-fb1 '. ,, . <? .. ),, I r-ry1 ,(:/4_ C? ~~-, . .. ' o/G ~-~~,;1w...r WI/ .,;,:1.' / ,· ~ ' Ult~JM\Q dAk!.~./ .:-J~ i;1 ()n· s---/,~ t:)_j" -/""/'Q,"',.i'J ·chca ~-I r'u-RI ~J 'tto1-ro ~ tJitl!"?eer q,!t)I)/ d\l ~ l OetAd,, \.t~. ~hao tltc~\V\~ rlJ{f)~\ I. Jf / !. ! --J .. HOURS . Date,, Re. O.T. TIME IN . 1'1MEOUT /11 ,00 SAMPLJJ;_S Grout . Mortar ,Concrete Block Prisms Densit .. ' All inspections based on a minimum of 4 hours &, over 4 hours -8 hour minim'ufi!-. In addition, over_ 8 houts and Saturday will be billed at time iind a half · ATTORNE'i"S FEES -If-any action at law cir in. equity is brought to enforce or interpret.th,e terms of this Contract, the prevailing party shall be 'entitled to reasonable attorney's fees, costs and necessary disbursements in addition to any oth~~ relief to wl}ich such party may be entitled. · · · ' , Inspecm;, NanIB, S}a.V\ C~.r C ,:CIAL ;:::::n::POa ~' ~ I.D, No. $.4) ...\1. 'Iii. C has been filed and it states that the above work to the best of his/her knowledge complies with the ,,provisions· of the Unifonn Building Code and meets Approved Plans and SQpc · c'ati.6n. ) . '-~fftfully Submitte~ Approved by: t:5fr~4i 6./4 tk'/L,,PYI-~ ~y ~/:'-c:r-~.:;,,;".£.6~,;,1~-:t,,';!M~-~-~~-,,,~-cF~:;c.._ "!--· ·~-·........,===-----f v. . ProjectSuperintendent _ -~ Ct ' -- ' -I '._, ... , .... ~"'" v,-·~ \,.-.. ~1•'""·~-', ... ,.,. ,, •'' ~•' ,,_, , -, ,,. , , ,_ ,.-• I I'\ A , ,.' ,,._.'. p.~.,-t}'.· ' 1~1)\t~ /-?f;., , , . c.Ase1J>.r.o .INsPEcTroN sERvrcE·s: DEPT. oF BLDG. & SAFETY ~929 Fire Mountain Dr. Suite #57 _/"i' / L J ---- Oceanside, CA 92504 CITY OF {._c;.,-, / / ..S f:i~ d (714) 404-7413 " ' (' ;ti" 0-1 COUNTY OF ... )~ ~ U/ e~ 'J G FAX (760) 722-0985 ~-:-. SPECIAL INSPECTION REPORT i/ . ' #, r (J' th.I/ r~ /.,..t 7lf ,....., c..-, r· ""'? 2 t./.... -BuildingPermitNo. ~()r .. r a ·T JobNo. <--di"/ o.,:,,,.. Date 0-J~ -,-OS Jobidentification/Address llcJclr S~·/t. 2:iCJo r~r.J;t;J,c/4,,,., General Contractor/ Address /'-?. 0 e I C cu:1 i:f""i/f#t t:-::1'7 l'.U-'1 . ' z,, /:,_ Sub-Contractor/ Address 1-/§111 I VI t!1 -;,r i:.1 !'1t.-1S llUt'i. C ({;/t'"A J:? Structural Engineer/Address t.~r:.'H?. l./ /-t Af\.f\v-..\i<l ds: Ah,, M1c?e E;,,t:':/140.-G'rll-\ ~ TYPE OF.WORK: REINFORCED CONCRETE_ MASONR; I HI-TENsi6 BOLTING_:::__ PRESTRESSED CONCRETE_ WELDING I, GYPSUM CONCRETE WELDER ~CEIPT NUMBER WELDER RECEIPT NUMBER 1--1,..·r t~ ft t ii -//h/2nar \ · l vuu1 l ......, c_ ¥-,:t,J\ }t;v/.'l .J ~ -V DATE OF INSPECTION -· • DESCRIPTION OF WORK INSPECTED: . 0 ;s ... ? f,j... () f"' . It,.# _,, I U l.,skq / --j'r, \/ii; __ ' r t(J f /1."'i t!. C ,.,d,-91,.____f,h;;?e ~ / .I dk-? Cl-.---~:, I I ;. t,~ (.,•;:, 1I Q \...,-..1.Q. le/..; ..,~ ,~ I f -a~r:..-I{-e,~,?p IA. j {4 i""J', /'J /-:--- ~ / ' #V#/% I} G (I I /'~ '7'_ ~J ' .,Ji ~~ __ ,;..../tQf.", ~1 .. r ~ ?-, 1 '@ t::> • t..A.,,lt? Cl.. -A<"'> J\ 's /.--~C)l,11""?J/ ,r....-, · . 16 ./fl~ .r 0/. ""'"' ' .,.,f ~£4 cl "(?;-~Ci..~ e r- <:? la..~4 r~II (')~-r~ -I~, t""I IA,':-.1 /2.P? (:} ... p 1.-., ~' I, C / {! f--. fY 12. A<_/2 e .. t1 ;,./ ~vie/ ;;;? ea..-: ii r ----... V! .1? ;::::,~() /] • .. ' .. ,l ,~~~ ;;I..J. 2 c-·-~,,r _,J_ /) / . //I . /4 ~,<:: .. Q ~}(-2. (._ C;< f 1~1. ~ C J .. ~·--•'\:·1 /c, ()/ .. :A ~ t..,;,.- --Date -,,,,, Grout - (-\,-;-~ . . d . \ t-n V\f s rv.. .... LA ,.3' \ h ~ i.\ 1111 /JJAJ _ W/l:76/f,J . , H .... /C'Glt HOURS Re. 0.T. SAMPLES Mortar Concrete !)~~k L,1.J,: ~ rf TIME IN ,;.., ""';"",-,. l'.Ji-·.....,'j ¥ Block Prisms f'?racc .r c \c1i. W12~ TIMEOUT - Densit Alf wspections based on a minimum of 4 hours & over 4 hours -8 hour minimum. In addition, over 8 hours and Saturday will be billed at time and a half. ft t"l"'r ATTORNEY'S FEES -If any aetion at law or in equity is brought to enforce or interpret the terms of this Contract, the prevailing party ... shall be entitled to reasonable attorney's fees, costs and necessary disbursements in addition to any other relief to which such party may be entitled. 0-(''_ . SPECIAL INSPECTION REPO,~ ~ Inspector's N~e:)! .. ::11-.vt~ ..... (-tr (J n n Inspector's SignatureJ1-L.,./4~~ C .>!C,----:""'_ ··; I.D. No. ~·rJ1\ . 'J~~!, Ms'b~en.filed and 1t states that the above work to tlie best of his/her knowledge comp hes with the· provisions of th~ Uniform Bui19.fn;9dde and meets Approved Plans and Specification. ~ ,);_ ,--z;,;.,,_-------l......_ espect u y Su m1tted M/ ~~.e..-l R f 11 b . I ;.Y · (-"J :<~· , --·t , r,w.-·-:·.Y I Approved by: ,, ~ _f-". . _ .. /,::;,,,/:Jr'JZ-(~l'-4 _")..! 1\/By -----,---~-________ _ ·. i ''--.. __ '. Project Superintendent ' ~ ·-~~~ . .: .. · m 56f:-94-1-299tZl SCWTHWEST INSPECTION AND TESTING INC. 10826 S. Norwalk 4*A Banta Fe Springs~ CA 90670 7 :t 4-5i.=.::6--84i.~ 1 ,·- -----~------------------------------~ ----~-----------------------~=~~----====--FIELD DATr~ DN 'TEST SPECIMENS ,, ASTM C31, CONCRETE; X GROUT: C138, Cl.l.:-3i MORTAR:: C:l. 725 Cl 73, C2:3:I. 2 C10G4· SHOTCRETE: CORES ff GUNITE1 ADDRESS: f::c::(WZI FA RP.DAV, CARLSBt:!tD~ CA. JOB Nc=iME: ROC!·{ STAR JOB I~ DATE: 6/30/2005 PERMIT i: CB044184 ISSUED BY: ARCHITECT~ CONTRACTOR1 ROEL CONST. ENGINEER~ HOPE ENGINEERING SUB CONTRACTOR~ ROEL CONST. LOCATION IN STRUCTURE: 2ND. FLOOR F 3.5 LINE ----------------------------------~--------------------------------------------1=11_ i::,)f\11"' fi i:.! CONCRETE SUPPLIER~ SUPERIOR TYPE OF CEMENT: II/V ADMIXTURE: ( ·· inATER. A-OOEif: -5 -Gf-U;;;.-•. · ' MI X ~* : 8355P TI cgE-r:. *~ ~ . 281-023 S!~,Ui"IP : · '-1· 1 / i::!u · CONCRETE TEMP~ 83 F MIXING TIME: DATE CAST: 5/24/2005 SPEC I MENS MADE BY: DAN c(.:1sc I ND INSPECT I ON FIEt.D IDENTIFICATION! A B LAB IDENTIFICATION : OT52420 : OT5242JZi · AIR--TEMP:- TIME CAST~ RECEIVED AT LAB~ 5/25/2005 SPECIFIED PSI: 3000 C D· : OT5242lZI E """"'.-..... -.. -.. ----------·----·----.. ·-·-.. --.-.... ___________ _..._ .. _____ , ____ ...... , .... _., _________ , __ .,. _________________ .. ______ _ AGE DAYS n 7 28 . 2fl u • . . • . Df:)TE TEST . 5/31/2tZIIZ15 = 6/i21 /21Zl~!i5 . G/21 /i:=:!Zl05 ~ . " . . SIZE -IN. " 6 Q IZll!ilZI X 12 = 6. 0,21,zix 12 . s. 0e10x1.2 : : • . AREA-SQ. IN. . 28u2"7 . 28.27 28. "c-~7 : . . • . CRUSH LOf-lD-·LBS . 74-35tZ1 . 102'301ZI . 11zr:1.;200 . . . . • . . COMP·-STR. --PSI. . 2531Zl " 3.EA0 R 358121 . . • . • . I HID . . u ~ " ~ . . NOTICE: These test results are from samples cast by inspectors CORR FACTOR ll . . . . or technicians not employed by our firm. They were CORR.STR.-PSI . . either deliv~red to our laboratory ortJ>icked up by our . . TIME TESTED . :: n driver. We Vf)H accept no responsibility, for the Inspection . . made on thii Jobsite, results of the&11 lasts, any error or BREA!{ TYPE • : . omission o~h• jobSlte_Qy t!le inspector, lurtherl1l!)re we_ . • . Cu T. M.· USED· .. • -i:,.~ --~~ ·:--. _ . do notJak--.raspcmslblJlty for any intoimati9n on this • . report other1hen the strength as testea and reported. · REMARH.S: ____ ,. ___ .. ______ ~------.... ------------·--------··-," _ ...... -·--·--------·-.. ·----..... ___ .. -.. -----· - COMPLIES: X ASTM C39, C174, C192, C4709 C617, C42 DOES NOT COMPLY~ THIS REPORT SHALL NOT BE REPRODUCED? EXCEPT IN FULL l,HTHOUT THE APROVAL. OF SITI SAMPLES CAST BY OTHERS: ~4STM C39 BREAl{S A= cone B= cone and split C= cone D=shear E:::::columnar (. -· DATE: January 19, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4184 EsGil Corporation In Partnersliip witli <]ovemmentfor<JJuilaing Safety SET: III PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Rockstar Office TI D APPLICANT ~URIS'.) D PLAN REVIEWER D FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZ! The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. · IX] The applicant's copy of the check list has been sent to: Charlene Reed 275-8 McCormick Ave., Costa Mesa, CA 92626 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant.that the plan check has been completed. Person contacted: .e3/lene Reed (__ 7,i'~() Telephone#: (714) 432-8756 Date conta~ted: tjlf/&;: (by/t-) &ic '&I Fax #: (714) 432-8956 Mail .....,:felephon~ Fa~ Person D REMARKS: ~ // d ' Ct'<.,1,/€ ( n. By: Sergio Azuela Esgil Corporation D GA D MB D EJ D PC Enclosures: 1/13 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ) f, Carlsbad 04-4184 January 19, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2200 Faraday Ave. DATE PLAN RECEIVED BY COMPLETED: ESGIL CORPORATION: 1/13 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-4184 SET: III DATE RECHECK January 19, 2005 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. B. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. · C. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes ONo /, Carlsbad 04-4184 January 19, 20QS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 23. Group A, Division 3 Occupancies located in the basement or above the first story should be of not less than one-hour fire-resistive construction. (Section 303.2.2.2). . • The building shall be a 1 hr type of construction. Original correction is still applicable. The building shall be clearly shown as Type of construction V-1 hr, instead of V-N. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ENERGY CONSERVATION 25. The Documentation Author and the Principal Lighting Designer must sign the J_ TG-1 form. THE IMPRINTED SET MUST BE SIGNED BEFORE PERMIT. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. l-' ·-DATE: January 6, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4184 EsGil Co_rporation In <Partnership with <]overnment for <Buiufi.ng Safety SET:11 PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Rockstar Office TI D APPLICANT ca Jumo D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Charlene Reed 275-B McCormick Ave., Costa Mesa, CA 92626 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacte~:/Ch,-rlene Reed Telephone#: (714) 432-8756 Date contacted: 1/ "'1/tl'(b~ Fax #: (714) 432-8956 Mail V Telephon,r ~ Fax ~ ~ers~n D REMARKS: <JM/ By: Sergio Azuela Esgil Corporation 1:81 GA 1:81 MB D EJ D PC Enclosures: 12/28 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 .I. • Carlsbad 04-4184 January 6, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2200 Faraday Ave. DATE PLAN RECEIVED BY ESGIL CORPORATION: 12/28 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-4184 SET: II DATE RECHECK COMPU;:TED: January 6, 2005 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approv~I of the plans does not permit the violation of any state, county or city law. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. B. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. C. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo I ' ' I Carlsbad 04-4184 January 6, 2005 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three. sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all' corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 18. Exit corridors shall not be interrupted by intervening rooms. Foyers, lobbies or reception rooms constructed as for corridors shall not be construed as intervening rooms. Section 1004.3.4.4. a) Still the corridor has been interrupted by the Shared Conference Room 204 and the adjacent unnamed Room. Original correction is still applicable. 23. Group A, Division 3 Occupancies located in the basement or above the first story should be of not less than one-hour fire-resistive construction. (Section 303.2.2.2). • The building shall be a 1 hr type of construction. Original correction is still applicabl~. 24. Provide at least one drinking fountain for each floor level in Group A occupancies. Section 2902.2. • The required drinking fountain was not provided. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ENERGY CONSERVATION 25. The Documentation Author and the Principal Lighting Designer must sign the L TG- 1 form. THE IMPRINTED SET MUST BE SIGNED BEFORE PERMIT. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. .. 1 Carlsbad 04-4184 January 6, 2005 __ PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 44. Clearly note on the drawings as per the response: "No hazardous materials as per the types listed in USC, Tables 3-D and/or 3-E, are proposed to be used and/or stored within the building." MECHANICAL (2000 UNIFORM MECHANICAL CODE) 4 7. On the mechanical plans clearly show the limits of ceiling space used as duct or plenum. (The limits of the ceiling plenum space is not clearly show on the drawing?) Then address the following: 8) Clearly note on the drawings that: "The flame-spread index is not more than 25 and the smoke-developed rating is not more than 50 for all combustibles material within the plenum space as per UMC Section 601.3." .. C) As per the 2000 UMC, Section 504.1, the Environmental exhaust duct systems shall not extend into or through ducts or plenums. Correct the Sheet Notes #5 on sheets M3.1A and M3.1 B: 1) The FireMaster grease duct wrap is no longer made by the 3M Company. Clearly show what product is proposed to be used. 2) The proposed grease duct wrap must be installed as per the lCBO listing of the product. Please provide a copy of the listing data and installation instructions. 3) None of the known grease duct wrap systems are listed to be 11 hour fire rating as required by the Sheet Notes #5 on sheets M3.1A and M3.18. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on·the plans. EsGil Corporation In <Partners nip witfi government for <Bui(aing Safety DATE: December 7, 2004 JURISDICTION: Carlsbad . PLAN CHECK NO.: 04-4184 PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Rockstar Office TI SET:I ~T OJURIB. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gj The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZ! The applicant's copy of the check list has been sent to: Charlene Reed 275-B McCormick Ave., Costa Mesa, CA 92626 '• D Esgil Corporation staff did not advise the applicant that the plan check has been completed. IZJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Charlene Reed Telephone#: (714) 432-8756 Date contacted: 12l/o 4 ~;Jf1-) Fax #: (71,1) 4~2-895? Mail\..,/""felephone/ Fa< In Person D REMARKS: By: Sergio Azuela Esgil Corporation [81 GA [81 MB O EJ O PC Enclosures: 11/22 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' . Carlsbad 04-4184 December 7, 2004 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 04-4184 OCCUPANCY: B JURISDICTION: Carlsbad USE: Offices TYPE OF CONSTRUCTION: V-N ACTUAL AREA: 40,735 SF (TI only) ALLOWABLE FLOOR AREA: UL {assumed) STORIES: 2 SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: HEIGHT: OCCUPANTLOAD: 335 DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/22 DATE INITIAL PLAN REVIEW COMPLETED: December 7, 2004 PLAN REVIEWER: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 USC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot ' l Carlsbad 04-4184 December 7, 2004 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC ·arid the 1999 NEC. 4. Indicate the use of all spaces adjacent to the area being remodeled or improved. 5. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. a) Please show on plans if the separation between the adjacent spaces and the proposed Tl space is an occupancy separation, please show it on plans for walls and floor to ceiling. 6. Note on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-0 and 16-B. 7. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 708. 8. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24. Carlsbad 04-4184 December 7, 2004 9. The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Title 24.Clearly show it on plans for door 205. 10. If exit signs are required, provide the following notes on the plans, per Section 1003.2.8.2: a) Exit signs shall be located as ne·cessary to clearly indicate the direction of egress travel. No point shall be more than 100 feet from the nearest visible sign. b) Exit signs shall be readily visible from any direction of approach. 11. Show that exits are lighted with at least one foot candle at floor level. Section 1003.2.9.2. 12. Exit doors should swing in the direction of exit travel when serving any hazardous area or when the area served has an occupant load of 50 or more. Section 1003.3.1.5. a) Door 234B. 13. Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access). Section 1003.3.1.6. 14. Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 1004.3. a) Clearly show it on plans for door 234A. 15. Exit doors from Group A occupancies shall not be provided with a latch or lock unless it is panic hardware. Section 1007. 16. All doors and gates, within the exit path from Group A occupancies to a public way, shall not be provided with latches or locks unless they are equipped with panic hardware. Section 1003.3.2.2. 17. When additional doors are provided for egress purposes, they shall conform to the width, swing_ and hardware pro.visions in Chapter 10. Section 1003.3.1.1. 18. Exit corridors shall not be interrupted by intervening rooms. Foyers, lobbies or reception rooms constructed as for corridors shall not be construed as intervening rooms. Section 1004.3.4.4. a) Coffee 209 at corridor 216/206. 19. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and 710." Carlsbad 04-4184 December 7, 2004 20. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 713.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 1004.3.4.3.2.1. a) Missing for doors: 204 ahd 205. • MISCELLANEOUS 21. Provide structural design calculations, shop drawings and specifications for the access floors. 22. See attached lists for: electrical, mechanical, plumbing and energy corrections. 23. Group A, Division 3 Occupancies located in the basement or above the first story should be of not less than one-hour fire-resistive construction. (Section 303.2.2.2). 24. Provide at least one drinking fountain for each floor level in Group A occupancies. Section 2902.2. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. /fyou have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Carlsbad 04-4184 December 7, 2004 ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ELECTRICAL (1999 NATIONAL ELECTRICAL CODE) 25. Show the ampere interrupting capacity (AIC) ratings of the service and sub- service equipment. NEC 110-9 26. Show or note on the plans the method used to limit fault currents to 10,000 amps on branch circuits. NEC 230-208 27. Show on the single line diagram the conduit and wire sizes for options shown on sheet E-7.1. 28. A ground fault circuit interrupter shall be installed in the branch circuit supplying fountain equipment. NEC 680-51 29. Provide GFI protected receptacle(s) within 25 feet of HVAC equipment. NEC 210-8(b)2 & 210-63. · 30. Commercial bathroom convenience receptacle outlets are required to be GFCI protected. NEC 210-8(b){1) 31. Please match information on single line with the plans. New electrical room options shown on E-7.1 should be accompanied with single line electrical diagrams. NEC 110-26, 230-2. 32. Show the location of all panels, load centers, switchboards; and transformers. NEC 110-26,240-24,300-21. 33. Provide overcurrent protection on the secondary side of transformers. NEC 240- 21 Ex., 384-16(d). 34. Provide multiple switch light controls so that the lighting can be reduced by one half in a uniform pattern. The switches must be located within sight of the lights which they control. CBC Title 24, Sec 131 a-b 35. Show exit signs on the lighting plan(s) at all required exits and specify them as being self-luminous or having a second source of power (battery or generator). This is required when two exits are required per the USC. UBC 1013.4 and NEC 700-16. 36. In all occupancies where the exit system serves 100 or more occupants, provide a minimum of 1 foot-candle of emergency illumination at the floor level and specify a second source of power for the emergency illumination (battery or generator). USC 1012.2 & NEC 700-16. Carlsbad 04-4184 December 7, 2004 37. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and " The overcurrent devices shall be AIC rated per manufacturers. labeling of the electrical equipment" . . • ENERGY CONSERVATION 38. The Documentation Author and the Principal Envelope Designer must sign the ENV-1 form. 39. The Documentation Author and the Principal Lig~ting Designer must sign the LTG-1 form. 40. The Documentation Author and the Principal Mechanical Designer must sign the MECH-1 form. 41. Specify on the building plans all of the mandatory energy conservation requirements-as listed on the enclosure titled, "Mandatory Measures Checklist". Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 42. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. 43. Correct the statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24 ), wtiich adopts the 1997 USC; 2001 edition of the California Mechanical Code," which adopts the 2000 UMC; the 2001 edition of the California Plumbing Code 2000, which adopts the UPC; and the 2001 edition of the California Electrical Code, which adopts the 1999 NEC. Carlsbad 04-4184 December 7, 2004 44. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. a) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). b) Clearly show the amounts of each type of hazardous material to be stored and in use. · · c) Clearly show where in the buildings each type of hazardous material is being stored or used. MECHANICAL (2000 UNIFORM MECHANICAL CODE) 45. The fire rated corridors are not to be used to convey air to or from rooms. UMC Section 602.1. The amount of air supplied to the fire rated corridor must be equal to the total amount of air being returned and exhausted from the same fire rated corridor. Please correct. 46. Provide smoke detection in the supply air duct of an "air-moving system" for required shut-off of equipment for smoke control. UMC Section 609.2. An "air- moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. UMC Section 203.0. 4 7. · On the mechanical plans clearly show the limits of ceiling space used as duct or plenum. Then address the following: a) Clearly note that all material exposed within the plenum complies with UMC Section 604.2. "Materials shall have a mold-, humidity-, and erosion-resistant face that meets the requirements of UL 181." b) Clearly note that all combustibles material within the plenum space must comply with UMC Section 601.3. Flame-spread index of not more than 25 and a smoke-developed rating of not more than 50. c) Note: as per the 2000 UMC, Section 504.1 (Code Change) the Environmental exhaust duct systems shall not extend into or through ducts or plenums. (UMC, Section 602.1 does not allow · negative pressure ducts in the plenum. UMC, Section 602.1, states: "See Chapter 5 for limitations on environmental air systems exhaust ducts extending into or through ducts or plenums." And: "Exhaust ducts under positive pressure and venting systems shall not extend into or pass through ducts or plenums.") PLUMBING (2000 UNIFORM PLUMBING CODE) 48. Plumbing is OK. Carlsbad 04-4184 December 7, 2004 Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. • REMODELS, ADDITIONS AND REPAIRS 1. When alterations, structural ·repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to · comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. d) Existing drinking fountains (if any) must be shown to comply with all_ accessibility features. • ACCESSIBLE PARKING 2. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high and located so that it is visible to traffic enforcement officials). Section 1129B.4.2. 3. Ramps shall not encroach into any accessible parking space or the adjacent access aisle. Section 1129B.4.3. Carlsbad 04-4184 December 7, 2004 • CURB RAMPS • Clearly show full compliance for all curb ramps included within the accessible routes of travel. Full compliance will be rechecked. • WALKS AND SIDEWALKS • Clearly show full compliance for all walks and sidewalks included within the accessible routes of travel. Full compliance will be rechecked. • PEDESTRIAN RAMPS • Clearly show full compliance for all pedestrian ramps included within the accessible routes of travel. Full compliance will be rechecked. • COUNTERS AND TABLES 4. Where fixed or built-in tables, counters or seats are provided for the public, and in general employee areas, 5% (but never less than one) must be accessible. Section 11228.1. 5. The tops of tables and counters shall be 28"-to 34" from the floor. Where a single counter contains more than one transaction station, such as a bank coun_ter with multiple teller window or a retail sales counter with multiple cash register stations, at least 5% (but never less than one of each type of station) shall be located at a section of counter that is at least 36" long and no more than 28" to 34" high. Section 11228.4. END OF DOCUMENT Carlsbad 04-4184 December 7, 2004 jVALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: -04-4184 PREPARED BY: Sergio Azuela BUILDING ADDRESS: 2200 Faraday Ave. DATE: December 7, 2004 Rockstar Offic"e TI BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-N BUILDING AREA Valuation Reg. VALUE PORTION (Sq.Ft.) Multiplier Mod. Office Tl 40735 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance __ ,;,, I Plan Check Fee by Ordinance '• I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee ----::1 Repeats __:J . Comments: D Other D Hourly I Hour * Esgil Plan Review Fee ($) 1,262,785 1,262,785 $3,613.441 $2,348.741 $2,023.531 Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING-APPROVALS ·-. RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) DATE_fi-t-(/2_1..-_,,,__/4_t_ TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER ___ --"-~--------------- DATE _______ _ . Oocs/Misforms/Plannlng Engineering Approvals -"' <.) Q) ,::; u C: "' a: "" "" t.) t.) Q) Q) ,::; ,::; (.) (.) C: C: "' ro 1i: 1i: D D DD DD PLANNING DEPABTMENT BUILDING PLAN CHECK REVIEW CHECKLIST / Plan Check No. CB 6Cf l /I ff { Address tP cJa.J ~A-P1:J= Planner Greg Fisher APN: ?-/ rr · /')--O '3 q Phone {760) 602-4629 Type of Project & Use: 01=f:'1..,c__ Net Project Density: _____ --=D'-=UC"-/A'-'-=C_ Zoning: GM. General Plan: P-:C Facilities Management Zone: ___ _ CFD (in/out) #_Date of participation: ____ Remaining net dev acres: __ _ Circle One (For non-residential development: Type of land used created by this permit: ____________________ ) Legend: [gl Item Complete D Item Incomplete -Needs your action Environmental Review Re_q_u_ir_e_d._· ---Y-ES_-.: ___ NO ~ TYPE DATE OF COMPLETION: / Compliance Vl(ith conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE ---- APPROVAL/RESO. NO. _______ DATE __ _ PROJECT NO. _________ _ OTHER RELATED CASES: __________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ----------------------- Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES __ NO CA Coastal Commission Authority? YES __ NO If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: YES NO (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data ·'Entry Completed? YES __ NO __ (A/P/Ds, Activity Maintenance, enter CB#, tool bar; Screens, Housing Fees, Construct Housing Y /N, Enter Fee, UPDATE!) H: \ADMI N\CO U NTER\BldgPlnchkRevChklst Rev 9/01 ~· 1111"""" ' ·DD · DD. DD DD DD DD DD ODD \ j ~ite Plan: I • .1-~ ...;t ,_. l. Provid~ a fully dime.hsibnai\site plan .drawn to scale. Show: North arrow, prop~~-t~(8iff13~;,.~ · ..... , ·. e~s.e~ents,. e?,<isting and ,proposed. str~·ctur:es, :stre.ets, existing street impr.ove,mentt, · :rr~nt-· of-way w'i'dth, dimensional setbacks c;1nd existing' topographical 'lines (including alt si.~·~ and rear ,yard slopes). .\ 2.. 'Provide legal description of prop~·rty and assessor's· .parcel number, Policy 44 -Neigl1t)orh99d Architectural Design Gui'delines . 1, .. Applicabili~y: YES ____ .NO_· _ __,_- 2. Project complies YES NO-__ _ Zoning: .t. $etbacks: Frnnt: Interior Side: Required Shown ------,--Req,Uired Shown ----------Street Side: Rear:. top of slope: Required: Shown --,---,---,---'--------,Required Shown ------,-- Re qui r Eid Shown -------,- 2. Accessory structure setbacks: Front: Hequired ------~----'-Shown _____ _ Interior Side: Required -'------"-'-----------'-Shown _____ _ Street Side:. Requited Shovvn -;-----,,--,----,--~ ------Re a r: Required ______ Shown _____ _ StruqtUre separation: Reguired Shown ____________ _ 3. Lot Coverage: Hequir.ed ---'"'-----Shown -----,-- 4. Height: Required: -"------Shown ------ 5 .. Parking: Spaces ,Required ------,---,,-Shown. ------ (breakdown by: uses 'for commercial c;1nd industrial projects required) Residential Guest Spaces Required -,-------,---,--, Shown ---..,----- ',, Additional Comments Correction #1 -Please ·show on Sheet 1 the total number of parking. spaces provided and. required ·on site for: each use. p~r· Chapter· 21 .44. Correction #2. ,,.. Is there any proposed: roof mdunted .. equfpment associated with this building permit? If ~o, Will the equipment. be. scr.eened, by an ~xi_stintJ parapet wall· or is new screening material regu.ired? Please see the attached 'handouts for_ examples. DATE,-~~()} .H:\ADMIN\COUNTER\BldgPlhchkRevCt,~lst · R!:!V 9/01 f CITY OF CARLSBAD PLANNING DEPARTMENT REVIEW LIST PC# 04-4184 Correction #1 -The cover sheet has been revised to reflect the correct parking count for the site. Sheet T0.1. Actual Floor area -2nd floor= 112,724 SF Area of Improvement-2nd floor= 40,735 SF Office= 40,735 @4/1000 Total Parking required= 163 spaces Parking Provided: Standard = 719 Compact = 148 (20%) Accessible = 10 Correction #2-New Tl work utilizes existing HVAC units in place, behind existing screen. No new units added. ,..~ c ~ -~ "i ', ~ -~ ~ .l!! ., ,S "' iii "' Cl Cl Cl i: >, ,c M 'II: :,,,, X x 0 " " Q) ., ., .s::: .<: .<: (.) u u C: C: C: "' "' .!!! a: a: 0. DD DD DD PLANNING DEPABTMENT BUILDING PLAN CH~CK REVIEW CHECKUST / Plan Check No. CB {JC(l(/ fJ( Address tflcJa.J ~A--/)12= Planner Greg Fisher Phone (760) 602-4629 APN: d ( q-· /,-..O ''3 q Type of Project & Use: 0 +=f=c.,'--- Zoning: CM. General Plan: Net Project Density: _____ __,D=c_U="--'-/ A-'-'C=--- p '.( Facilities Management Zone: ____ _ CFO (in/out) #_Date of participation: Remaining net dev acres: ------- Circle One (For non-residential development: Type of land used created by this permit: ____________________ ) Legend: (8J Item Complete D Item Incomplete -Needs your action Environmental Review Re_q_u_ire_d_: ____ Y_E_s_--: ___ No ~ TYPE DATE OF COMPLETION: / Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE ---- APPROVAL/RESO. NO. ______ DATE __ PROJECT NO. _________ _ OTHER RELATED CASES: ____________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ---------------'---------- Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES __ NO CA Coastal Commission Authority? YES__ NO If California· Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: YES NO (Effective date of lnclusionary Housing Ordinance -May 21, 1993 .) Data Entry Completed? YES __ NO __ (A/P/Ds, Activity Maintenance, enter CB#, tool bar; Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 ,ci [] DD DD DD DD DD DD ODD Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, str~ets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 2. Provide legal description of property and assessor's parcel number. Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES ____ NO ___ _ 2. Project complies YES NO ___ _ Zoning: 1 . Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: · Required Shown Top of slope: Required Shown 2. Accessory structure setbacks: Front: Required ------Shown ------Interior Side: Required ------Shown ------Street Side: Required ------Shown ------Rear: Required _· _____ _ Shown -----,--Structure separation: Reguired _____ _ Shown ------ 3.. Lot Coverage: Required ------Shown ------ 4. Height: Required ------Shown ------ 5. Parking: Spaces Required _____ _ Shown ------ (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required ______ Shown _____ _ Additional Comments Correction #1 -P_lease show on Sheet 1 the total number of parking spaces provided and required ·on site for each use per Chapter 21.44. Correction #2 -Is there any proposed roof mounted equipment associated with this building permit? If so, will the equipment be .screened by an existing parapet wall or is new screening material required? Please see the attached handouts for examples. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE ----- H:\ADMIN\COUNTER\BldgPlnchkRevChklst ,. Rev 9/01 Carlsbad Fire Department 044184 ~ 63_!3,-F-traday Ave. Carlsbad, CA 92008 Fire Prevention {760) 602-4660 Plan Review Requirements Category: Building Plan J<:~.,.,~~~"""-'C" Date of Report: 12/01/2004 Reviewed by: Name: Carrier & Johnson Address: 1301 Third Avenue City, State: San Diego CA 92101 Plan Checker: ____________ Job#: _04_4_18_4 ____ _ Job Name: Rockstar Bldg#: CB044181 ------------------==- Job Address: 2200 Faraday Avenue Ste. or Bldg. No. IZ! Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and I or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and I or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 044184 2nd F.D File# 3rd . Other Agency ID 0 PATCH & REPAIR FIRE ~ 0 SATING PER CODE TO CREATE 1-HR. ENVELOPE 0 DRYWALL BACK SIDE OF EXISTING STUDS & TAPE. 0 PROVIDE 1-HR. RATED SHAFT WALL, REFERE TO DETAIL SH-1 ON PG. 2 ATTACHED 0 EXISTING 1-HR. RATED WALL TO REMAIN AS IS 0 PROVIDE 1-HR. RATED WALL, REFER TO DETAIL 8. 0 PROVIDE WALL MTD. EXIT SIGN, RELOCATE EXIST. 0-- ' '° ALIGN IA BUILDING VESTIBULE CT[[] EXISTING I-HOUR LOBBY (OPEN TD BELOIJ) r:::=i y ARCHITECTURE DESCRIPTION: _,_1-'-H-=O-=UR-'--"-"LO=BB=Y_;/'---=-'2N=D-'-F-'=-'LO"""'O.!..!...R __ Pc..,,G'-'--. _,.__1 ---"'OC!....F -=-2 ______ _ INTERIOR DESIGN PLANNING 2758 MC CORMICK AVENUE COSTA MESA, CA 92626 SKETCH NO.: EXHIBIT 1A / DELTA 10 RE-SUBMITTAL PROJECT: ROCKSTAR PH 714 432 8756 PROJECT NO.: 4622.00 FAX 714 432 8956 --'-------------------- G.E. CARRIER, ARCHITECT DATE: 05.26.05 SCALE: AS NOTED 2 11 ARCHITECTURE INTERIOR DESIGN PLANNING 275B MC CORMICK AVENUE COSTA MESA, CA 92626 PH 714 432 8756 , FAX 714 432 8956 G.E. CARRIER, ARCHITECT ~ TOP OF SLAB ----4PCF MINERAL YIOOL FIRESAf"ING IN-FILL AT FLUTES OF DECK (ICBO #0001) ---J-RUNNER TRACK, 20 GA. TOP TRACK. YI/ HILT! DNl-19-P8 POWDER DRIVEN FASTENERS AT 24"o.c. W/ 3/4" EMBED (I.C.B.O. #5457) ~: ~ \ 'l_ STRUCTURE '' ' ' .f . .f. ~ONTINUOUS FIRE-RATED SEAi.ANT 4---lt,;:,.,ll.==~'~I''' ==::~::=::t:==~'.~~:'.::= L CEILING PER FINISH SCHEDULE, IF REQUIRED ~ ~ ~ !i : •. :--a° TYPE 'X' GYP. BO.(# OF LAYERS PER BELOW) '=l.-le-,11---MINERAL WOOL BATT INSULATION ::i ---'"-"':JL.-=4,--Lf..J!.-L METAL 'J" RUNNER W/ POWDER DRIVEN ANCHORS: HILT! DNl-19-P8 AT 24'o.c. W/ 1' EMBED (1.C.B.O. #5457) BASE: SEE FINISH SCHEOULE CONTINUOUS FIRE-RATED SEALANT TYPE DESCRIPTION STC FIRE FIRE RATING TEST NO. NOM. RATING RATING DIM. SH-1 4' , 25 GA. C-H STUD fRMIING AT 24'o.c. W/ (1) LAYER GW8 SIC 45 1 HR U.L. /U469 4 5/8' -;-c~-L~-, -~-.T.·s~ ... A ....... L_L,..TYP.,..;,,;;.,.E.s ............. _ ........................................ .,.... ... sH""'-w"'"A"""~e DESCRIPTION: SHAFT WALL DETAIL PG. 2 OF 2 SKETCH NO.: EXHIBIT-1A / DELTA 10 RE-SUBMITTAL PROJECT: ROCKSTAR PROJECT NO.: 4622.00 DATE: 04.25.05 SCALE: ----'A=S'-'-'-NO::...:T=ED~ \( ~0~t~~: ~!.!r.y~! ~~!~=.~~~2008 03-29-2005 ~ Plan Check Revision Permit No: PCR05034 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: 2200 FARADAY AV CBAD PCR I Status: Parcel No: Valuation: Reference #: 2121203700 $0.00 CB044184 Lot#: 0 Applied: Construction Type: NEW Entered By: Plan Approved: Issued: Project Title: ROCK STAR SAN DIEGO , Inspect Area: ADD ELEC & MECH TO SOUND STUDIO/ OFFICES Applicant: ROEL CONSTRUCTION CO INC 3366 KURTZ ST SAN DIEGO, CA 92110 • 619-297-4156 Plan Check Revision Fee Additional Fees Total Fees: $240.00 Owner: E QB P-1 LL C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA 92037 Total Payments To Date: $0.00 Balance Due: ISSUED 02/24/2005 SB 03/28/2005 03/29/2005 $240.00 $0.00 $240.00 -4773 03/29/05 0002 01 02 Inspector: FINAL APPROVAL Date: CGF::: 24-0nOO Clearance: ------- NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitAtions has nreviouslv otherwise exoired. I Q \So~ t-( l CB~ ~ 7uo · voi.: ~'5'3 8 FOR OFFICE USE,5}NL Y PLAN CHECK No/ V fLcS'o 3c.j "' PERMIT' APPLICATION EST. VAL. _________ _ • ITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Plan Ck. Deposit_~-------- Validated By_~.,,,. =-/-~-+' ---,=-"'---- Date Z ,j Z, '1 {D < -·------·~-.,....-.-----...========:======--. ··:-,. -.-·--"' l Business Name (at this address) Phase No. Total# of units PrOROSed Use,__ Mci'" c:::T ec. .J- # of Bedrooms NameV Address I City State/Zip Telephone# lfu'..: -c'oN"tRMi:r~PANfNAivi'e ,w _ , .. :-._ .: , · -... ::.i (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by an applicant for a permit subjects the ap licant to a civil penalty of not mo e than Ive hundred dollars $500]}. ' ' u,LP U , Address ity Telephone# State License# _________ _ License Class ___________ _ City Business License# ___________ _ esigner Name Address City State/Zip Telephone# State License# ________ _ ~ ..,.VV,QRf<i;Wl;l ~PENSAll:ION--• ·--i~"1~~..:...:.::J W~~on Declaration: I hereby affirm under penalty of pe~ury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company ________________ Policy No. ____________ Expiration Date __________ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100,000), in addition to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees. SIGNATURE DATE f[,""')C'iW~l'{-BQICJ?_E~•Qi;~LARA'rlQN '_ , , · ., · : •. · ~: ~ . -.. _:';-, :-] I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name/ address/ phone number/ contractors license number): • 5. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ /ontractors license number):---------------------------------------------- 1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work): PROPERTY OWNER SIGNATURE ___________________________ DATE ___________ _ WHITE: File YELLOW: Applicant PINK: Finance (. )' PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT .635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 /CQMP!-iITE Tl-11$'SECTION'F.QR MON-Rt:S/Ql;NT/AL:BUIL;DING•PERIV!ITS Q!'JC'Y . Is the applicant or fut~re building occupant required to submit a business plan, acutely hazardous materials registration for o·r risk management and prevention pro.gram under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES' NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES X NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES ~O IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~8. _ CON~TRUCTIOfll~GAGEfWf . _ -~>. ~ ~ .. ~ : ... __ ~.· · _ · ....... · .~ ... _ ... , ... _ .... . I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME __________________ _ LENDER'S ADDRESS ___________________ _ ~--, APPi:tCANT·CE~TJr;ICATIQ°'N ..... ',_ -, : · --,. ;~ ... ~ "'.. · -· . , " -~. ·._·, :" ~-~--:;-7" --··~--~~~~-~ "i"certify.thatl have read the applicati'6nand statethatthe above fnformation is correct andthatthe.Tntormationonthii'plans is accurate. I "agreeto-compiy"with iiii"ciiy ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for r=.4.4 Uniform Building Code). APPLICANrSSIGNATURE~ ~i ll DATE~~~~<~ • • WHITE: File YELLOW: Applicant PINK: Finance Carlsbad 04-4184 PCR05-034 March 24, 2005 EsGil Corporation In <Partnersliip witli qovernmentfor(}Juifaine Safety DATE: March 24, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4184 PCR05-034 PROJECT ADDRESS: 2200 Faraday Ave. SET: II (REV) PROJECT NAME: Rockstar -Office Tl -Proposed Plan Changes D APPLICANT ~ D PLAN REVIEWER D FILE IZ] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The pla-ns transmitted herewith will substantially comply with the jurisdiction's building codes when minor defic_iencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: IZ] Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person D REMARKS: By: Sergio Azuela Esgil Corporation D GA D MB D EJ D PC 3/17 Enclosures: trnsmtl.dot DATE: March 4, 2005 JURISDICTION: Carlsbad EsGil Corporation In (l'artnersli.ip witfi. qovemment for rJ3ui{aing Safety PLAN CHECK NO.: PCR0S-034 ( Ol.f .• 4 I i'-1) SET: I (REV) PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Rockstar -Office TI -Proposed Plan Changes D APeLICANT CoJU~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gj The check list transmitted herewith is for your information. The plans are being held at Esgil . Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gj The applicant's copy of the check list has been sent to: Charlene Reed 275 B McCormick Ave., Costa Mesa, CA 92626 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [gj Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Charlene Reed Telephone#: (714) 432-8756 (vt-Jf:Y<Pdu3--6 L Date contacted:3 f 'tlaS (by:~) Fax #: (-:,,-l..r). ~ . Mail Telephone · Fax_....---In Person D REMARKS: By: Sergio Azuela Esgil Corporation D GA D MB D EJ D PC Enclosures: 2/25 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 { Carlsbad PCR05-034 March 4, 2005 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2200 Faraday Ave. DATE PLAN RECEIVED BY ESGIL CORPORATION: 2/25 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: PCR05-034 DATE REVIEW COMPLETED: March 4, 2005 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the originals and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes D No Carlsbad PCR0S-034 March 4, 2005 1. Provide a complete lists of all proposed plan changes, including: a) A brief description of each proposed plan change. b) The sheet or sheets of plans that area changed because each proposed plan change. c) The Identification Number and symbol used to identify each proposed plan change. • Please note that the required list is essential for plan check. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Carlsbad PCR05-034 March 4, 2005 ~ALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PCR05-034 PREPARED BY: Sergio Azuela DATE: March 4, 2005 BUILDING ADDRESS: 2200 Faraday Ave. Rockstar Office TI/Plan Changes BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-N BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Time Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1991 UBC Building Permit Fee 1991 UBC Plan Check Fee Type of Review: D Complete Review D Structural Only D Repetitive Fee 3Repeats * Based on hourly rate Comments: D Other 0 Hourly 21 Hours* Esgil ·Plan Review Fee ($) $240.ool $192.001 Sheet 1 of 1 macvalue.doc 2200 Faraday, Carlsbad, CA P. C. # PCR05034 Revision to permit #CB044184 Rockstar Architectural Drawings: Sh t# D ee ·r escr1p1 10n o f Ch ange 1 TO.1 Add sheet number A8.4 to index 2 A2.1.1 . At room 202 'Bike Storage' -room and door #202 have been eliminated and are now a part of the shiooina and receivina area #203 3 Room 268 -door location has changed and walls surrounding are to be 1-hr rated. Room 269 & 270 have been re-allocated, walls and door locations have changed as noted. 4 Location of door 201 has chanaed 5 Ramped area at Southwest corner of building has been modified to be surrounded by partial height walls for access to rooms 262 & 262 to aviod buildina a platform 6 A2.1.2 Area 227A-227K has been dimensioned and detail call-outs & wall types have been added 7 Door #245B has been added at wall between area 245 & 252 for convenience access 8 Relocated duct at room 234A is to be built as 1- hr. rated shaft wall 9 At room 234A (adjacent to door 234B) -column is furred out to receive a mechanical duct that needs to be relocated 10 A3.1.1 Room 203 shows 2 fixtures relocated. Room 269 & 270 shows fixtures relocated to suit new room layout 11 A3.2.1 At area 227 A-227K, ceiling and lighting plan have been identified with height references and corresoondina kevnotes 12 A3.1.3 Updated draftstop locations are show crossing corridors 13 A5.1.2 At area 227 A-227K, interior finishes have been identified and keynotes #5 & #5 have been added 14 A-7.1 Elevation #5 has been revised to show partial height wall with full height support. Elevation 1 & 2 are revised to show separation of frame and sideliaht. Rockstar -Revision to Plan Check Yellow indicates sheets added f ram 2/24/05 submittal en, ,e 1y: Id ff" db clouded sheet number under 'Drawing Index' with Delta #7 Clouded area with Delta #7 clouded area with Delta #7 clouded area with Delta #8 clouded area with Delta #7 clouded area with Delta #7 clouded area with Delta #7 clouded area with Delta #8 clouded area with Delta #7 at room 234 clouded area with Delta #7 clouded area with Delta #7 on plan and under RCP Plan Key Notes #5 & #6 clouded area with Delta #7 clouded area with Delta #7 on plan and under Finish Plan Key Notes #5 & #6 Elevation 5 has been clouded and referenced with Delta #7 , ...... ' . 15 A-7.4 Elevations 8 A-D have been added to identify the Elevation 8 label has been clouded & labeled finishes at Foley Room #227H Delta #7 to identify the added elevations to this sheet 16 A8.1 Detail D2 has been added to show the proposed Detail D2, FR, AC have been clouded and slip-trac solution to be used at full height walls, referenced with Delta #7 Detail FR & AC have been modified to reference this detail 17 Detail E1 has been added to show shaft wall Detail E1 has been clouded and referenced construction with Delta #7 18 Detail D4 has been modified to show a frame Detail D4 has been clouded and referenced assembly at both head and sill of the clerestory with Delta #7 window 19 A8.4 This sheet has been added to show the detailed Drawing Number has been clouded and wall construciton for Area 227 A-227K which is referenced with Delta #7 to indicate the new referenced on sheet A2.1 .2 sheet addition 20 A9.0 Doors 2278, C, D, G, H, I, J &K have been Door #'s have been clouded, and Door changed to reflect a better suited sound rated Schedule Note #15 has been clouded indicating assembly for their specific use. Keynote #15 has a change, referenced with Delta #7 been added 21 Door 254B has been added and Hardware type Door # has been clouded under Door Schedule #5 has been modified for the pair of doors and HDWR-5 has been clouded, both referenced with Delta #7 22 Card reader locations have been added clouded area with Delta #7 23 Door 269 has been eliminated clouded area with Delta #7 24 A9.1 New finish references have been added under All additional materials have been clouded and Wallcovering, Suspended Ceiling Tiles and referenced with Delta #7 Specialties Mechanical Engineering Drawings: Sh # D . f f Ch eet escr1p 10n o ange ent11e 1y: Id T db M1.1 Roof Top unit AC/1 BE has been annotated with clouded area with Delta #7 Delta #7. Information was previously reflected, but did not have the delta # assigned to it 25 26 M1.2 2 VAV boxes and 7 diffuser/registers have been clouded area with Delta #7 annotated with Delta # 7 reflecting their incorporation into the project. Information was previously reflected, but did not have a Delta # assioned to it. 27 M3.1A clouded area with Delta #7 VAV-241 and VAV-242 and associated ductwork and diffusers to serve edit suite added. 28 M4.1A Added thermostats to control VAV-241 and VAV-clouded area with Delta #7 242 29 M4.1B Change to room 268 only clouded area with Delta #8 30 M5.1B New AG unit at roof clouded area with Delta #8 Rockstar -Revision to Plan Check 2 .. Electrical Engineering Drawings: Sh t# D . f f Ch ee escr1p; 10n o ange en 11e 1y: Id ff db 31 E-1.2 Two new light fixture types have been added, F14 & F15 on the Luminaire Schedule have F14 & F15. Additional power added to smoke fire been clouded and referenced with Delta #7 dampers. 32 E-1.3 Modification to the Lighting Control Relay Relay R25 has been clouded and referenced Schedule has been added, (see 4/E-1.3) with Delta #7 33 E-2.1 Area 227 A-227K lighting plan has been identified Area 227 A-227K has been clouded and referenced with Delta #7 34 E-3.1 Area 227 A-227K power & signal plan has been Area 227 A-227K has been clouded and identified referenced with Delta #8 35 E-3.2 clouded area with Delta #7 Addional power to smoke fire dampers & Revised circuits and added new outlets to raise floor. 36 E-4.2 Modifications to roof top equipment and keynotes Area along column line D3 has been clouded have been added. Added conduits for satellite and Keynotes #3 & 4 have been clouded. dish. Areas are referenced with Delta #7 37 E5.1 Added new panel '2RD6'. clouded area with Delta #7 38 E-6.1 Panel Schedules have been modified to See areas clouded and referenced with Delta incorporate the changes to area 227 A-227K & #7 for panel 2RD2, 2RA2, & 2LD Added panel schedule '2RD6'. 39 E-7.1 Revised Detail 2/E7.1 to show one EPO switch. clouded area with Delta #7 40 E-7.2 Revised detail 4/E-7.2 (addtional outlets in server clouded area with Delta #7 room) Rockstar -Revision to Plan Check 3 ,-PCR05034 2Juo FARADAY AV CBAD ROCK STAR SAN DIEGO ADD ELEC & MECH TO SOOUND STUDIO/ OFFIC PCR Lot#: ROEL CONSTRUCTION CO INC ~ ::iJ;)-LJ /o5 {)~ Q_ cBb -I. -12-0.() pQR., &1f;fT 1!J> f;~(]<L_ W / CJ::>Oy, 41~ ()NJA., 3 ;4)o5 e,,,s<r, L e LI'\'\ . 3-ll(-O'S ~ -/Jw/tf,vM .J].7:i ~-~ Mft <P ;1C.Cw<e~ ]/rtloJ ev~ /""-cJ/ ~ ':':] j1)/t,f'./ -f!to;:J;J i, CJt1L- ~ SU tJj ~ U 3 f~~ ~ 3(6a'{:,tz f7J-/Ur jl)eed ~ be_ 5 !,,a r4 ee+4 f {o//~ @J /Jd IJ{t&ff ?/z~/6',; ~r:?'1) *BUILDING PLANNING ENGINEERING -------FIRE APPR/FORM ------HEALTH DEPT ------HAZWIT /AIRQUAL ------OTHER SEWER DISTR TO FROM APPL SCHOOLFORM ____ ,__ ___ CFDFORM PE & M WORKSHEET ____ ,__ ___ BLDG FEES COMPLE1'··. PLAN CORR ---,..--ENG CORR ---+---r~ras""' ESGIL CORR ____ .FIRE CORR City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 05-09-2005 Plan Check Revision Permit No: PCR05069 Building Inspection Request Line (760) 602-2725 Job Address: 2200 FARADAY AV CBAD Permit Type: Parcel No: Valuation: Reference #: PCR 2121203700 $0.00 CB044184 Status: Lot#: 0 Applied: Construction Type: VN Entered By: Project Title: ~ND FLOOR REVISE Plan Approved: Issued: Inspect Area: ISSUED 04/08/2005 KG 05/09/2005 05/09/2005 Applicant: ROEL CONSTRUCTION CO INC 3366 KURTZ ST SAN DIEGO, CA 92110 619-297-4156 Plan Check Revision Fee Additional Fees Total Fees: $240.00 Inspector: Owner: E QB P-1 LL C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA 92037 $240.00 $0.00 Total Payments To Date: $0.00 Balance Due: $240.00 FINAL APPROVAL Date: 7765 05/09/05 0002 01 CGF• Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this,project. NOR DOES IT APPLY to any feeslexar.tions of which vou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has oreviouslv otherwise exoired. 02 240-00 . OflG C 06l/L/L(){/ PERMIT APPLICATI.ON . d O / CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Legal Description~, 1 /J / O Lot No. Subdivision Name/Number ~~ 7a,37,o Assessor's Parcel Existing Use #of Stories FOR OFFICE USE ONLY PLAN CHECK No.fCf2Q5CJ(t7 q EST. VAL _______ '---- Plan Ck. Deposit 9-, Validated By . Date 1/'--cf-:ps:-: Unit No, Phase No. Total # of units Proposed Use # of Bedrooms # of Bathrooms (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant !o"the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by an applicant for a permit subjecls the ap licant to a civil J)enalty of not mo than Ive hundred dollars $500]). lRLP U , Name· Address ity License Class ___________ _ Designer Name Address City State/Zip Telephone# State License# ________ _ Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the perfonnance of the work for which this pennit is issued. D I have and will maintain w~rker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this pennit is issued. My worker';; compensation Insurance carrier and policy number are: Insurance Company _________________ Policy No. ____________ Expiration Date. ___________ _ {THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) D CERTIFICATE OF EXEMPTION: I ce,t;!ify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand ollars($100,000), in addition to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees. SIGNATU.RE DATE I hereby affirm that I am exe'!lpt from the Contractol's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale.. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of provi11g lhat he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (finn) to provide the proposed construction (include name / address I phone number/ contractors license number): t I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone number/ /ontractors license number):---------------------------------------------- 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone number/ type of work): PROPERTY OWNER SIGNATURE __________________________ DATE __________ _ WHITE: File YELLOW: Applicant PINK: Finance EsGil Corporation In (J!artnersfiip witli qovernment for <Bui{aing Safety DATE: May 5, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4184 PCR05069 · PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Rockstar TI -Plan Changes SET: II (REV) CJ AP LICANT JURIS. CJ PLAN REVIEWER CJ FILE k8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the_ check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: k8J Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Dc;Ite contacted: (by: ) Fax#: Mail Telephone Fax In Person D REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/28 tmsmtl.dot EsGil Corporation In (]!artnersfi.ip witfi government for (Bui{aing Safety DATE: April 19, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4184 PCR05069 PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Rockstar TI -Plan Changes SET:I (REV) D@ANT D RIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [?s] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to -forward to the applicant contact person. [?s] The applicant's copy of the check list has been sent to: Charlene Reed 275 B, McCormick Ave., Costa Mesa, CA 92626 D Esgil Corporation staff did not advise the applicant that the plan check h,as been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Charlene Reed Telephone#: (714) 432-8756 Date contacted: ~/,a,{cS(by: \(J-1 Fax #: (714) 432-8956 Mail __,.elephone / Fax _.../fn Person D REMARKS: By: Sergio Azuela Esgil Corporation D GA D MB D EJ D PC Enclosures: 4/12 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Ca,rlsb~d 04-4184 PCR05069 April 19, 2005 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2200 Faraday Ave. DATE PLAN RECEIVED BY ESGIL CORPORATION: 4/12 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-4184 PCR05069 DATE REVIEW COMPLETED: April 19, 2005 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before.the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes D No Carlsbad 04-4184 PCR05069 April i9, 2005 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engine~ring and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM STRUCTURAL CONCRETE OVER 2500 PSI FIELD WELDING REQUIRED? YES YES REMARKS F'c = 3,000 PSI DETAIL SX-2 & SX-5 3. If special inspection is required, the designer shall complete the attached Special Inspection Notice. 4. Provide complete structural design calculations for equipment supporting framing members. Additional corrections may follow. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. .j Carlsbad 04-4184 PCR05069 April i9, 2005 !VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Sergio Azuela PLAN CHECK NO.: 04-4184 PCR05069 DATE: April 19, 2005 BUILDING ADDRESS: 2200 Faraday Ave. Rockstar TI/ Plan Changes BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-N BUILDING AREA Valuation Reg. VALUE PORTION (Sq.Ft.) Multiplier Mod. Time Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance . • ! Plan Check Fee by Ordinance Type of Review: D Complete Review D Structural Only D Repetitive Fee 3-Repeats * Based on hourly rate Comments: D Other El Hourly 2j Hours* Esgil Plan Review Fee ($) $240.ool $192.001 Sheet 1 of 1 macvalue.doc \ I I\ PLANNING/ENGINEERING APPROVALS PERMITNUMBERCB {.jµ(6YDATE ·lf ~//-o) ADDRESS_J_JaJ____,_+h_/2;:+/J;_~-t-r---. ~&~· __ .RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10.000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE· FAIRE COMPLETE OFFICE BUILDING ·orHER ®~l _____ .=._ _ _.;..... ___________ _ PLANNE~~ oAre g · V-//os DATE_--+-lf/4-'-'-70~. --=--l>- Carlsbad Fire Department 05069 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention Plan Review Requirements Category: Building Plan Reviewed by: 4 f,0)602-4660 Date of Report: _0_41_2?_1_20_0_5 _______ _ Name: Carrier & Johnson Address: 1301 Third Avenue City, State: San Diego CA 92101 Plan Checker: Job#: 05069 ------- Job Name: Rockstar Bldg #: PCR05069 -----------,.-------=-- Job Address: 2200 Faraday Av Ste. or Bldg. No. ------------------ IZI Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable·codes and I or standards. Please review carefully all comments attached. Please resubmit the necessary plans and I or specifications to this office for review and approval. 1st 05069 2nd FD File# 3rd Other Agency ID ,, • STRUCTURAL CALCULATIONS Rockstar San Diego Second Floor Tenant Improvement 2200 Faraday Avenue Carlsbad CA Prepared for: Staubach Company, The 11988 El Camino Real, Suite 150 San Diego, CA 92130 Prepared by: Hope Engineering 1301 Third Avenue, Suite 300 San Diego, CA 92101 April 20, 2005 HE Project# 205022.00 JQB ________ _;{d..=0:....:.52?~2~2~•:.._::0,~C~ HOPE ENGINEERING 1301 Third Ave., Ste. 300 San Diego, CA 92101 SHEETNO. ______ OF _____ -l-- CALCULATED sv __ ___,G __ A,__,___ DATE CJ4 Jo .5 I CHECKED BY _______ DATE _____ _ SCALE _____________ _ _ _ . ;.. ; __ :_ . _ L '=> E=cp JJD. · · t:=" '=-~ · N{pulifio·: _ ~pu Jf N.e,Pr___ _ __ L __ ; ___ _ · :5·v_4', ct.pi:,,p' i 7 ~ '} 4-· ~ ·)b: · M., ' · . ~A ' ' ,I -c:.' Cl ' • I 'r --J ..,;r-:~ + ' fu ~ ' ·. --.. ' ... -•. ·;--. -,.., .. --,----' .... _ v,,,,! .. ,'--. '· 1 : -_(..;'_ . ..;..'). --". r-r.r.-,._. ---... : .. --··· -- '. i . • ~ ------.-• --' ' _,! • --:!-___ J ___ :-. -------;'----' -! ---~------·------:--------'----; ___ -----t _. . . ·, --_, .... .. : .. : __ ~j;QJJJ .. -e~ ... F~ ___ :_P..£ . .li! 1-,-:.,_:; ___ --~--?-. -~L.x., .. S (_~' _: _ _ -· . -----, ..... , __ .. I ' I : , '> '-(V ' '' ! -, ----. -·--...,: __ ---------. ----_: --.:---· -!------i-----.:-------L ---------. ·-... . ~ -;_ ---.. --. , ; __ , __ ,+.------------__ l _____ ,,_, ___ ._ ,__ ----~-------. l . ' ' ! : i [ ; ' ' :"" : ........ , .. ·-~ ------~ -• t -·· 1---· ---~---, --;·------- ' J , , , ' I I · . , I I . , l... ' . ' ' .) i ' ~ Alt) ,.,..~,,_ : :r,ll Js, &J J,{ffri -_· ·. Li~"-. ···.··.·~·:·~f_-·tJ;r-:~-:-· ~~;:~~?"1: :.···· · . . . ; -'-~ ' · A ~. · : -~ r , -. -~ • . > ' I ---·-.... ~--· --.. -----··-.. ··:·-1-·-·(---~ -----· · -· -1---:---· ---------·-- . --~-L.: ; : ' jj-. i ' ; -r--t-:--: : 1-·"- i ' -·. r---- ---' -- I ' ' -• ---.. , ' • --! - ., -----~------i-_.:PJ4A~ VI,!;; w ', ----.. -... . . - -· --1:>rii ~;JjirE~_r··-:_ ... _ -~/4---~---;/;:,d _1bj:_ ; .. ·:·_· ·1p--~_p_s1:-< __ ;tf)-,---/> s;· .------ : ' i t~G1%~;,.~/~T6\· ... t ALu>i,,, 'c . •. /,'1-) (: ) : i LL. f'¢ie.," ____ ;· -;, ~-. :><-3_._o/ '_ .. ! :_ t2~J~il./.A.1l. _ . ; D ~fl. UJJ,).)t:, .S- , __ _Efx;1s1JJJ.~ .. Die)~· CH e:vte : I . II ' -· ' I i / 1/: . l 1::; G A.' i ) : z_ JJ ' : i 1 · · '?-l_f:.Q ..... ""t°, \JJ. .... t'2. · .N,. ' Sf A 1.i :: ~ 1 -0 11 : 0 ~ c.-• · -At .. ,JA th., 4-.0 fVJ . -::: . _ .. 3.tx.). f 5/= Joo PS_F > .. o/.t-?-_f>Sff ______ . --. .....,... . . -. .....--,·---.-~···_. -::-·· -~ .. _; __ . {_§) Mf?Tkt.... I:GCK-Dtc. __ . ____ ~-, . _, ____ ,.. ~ " 2,0 7ozz..oo B-fO.RIVILOK NORMAL WEIGHT CONCRETE (145 pcf) GALVANIZED OR P-HOSPHATIZED/PAINTED TOTAL l SLAB _} _ _: 0 • • •• • • • ·: • • • •0 •• • •. • • • o • • •. • • DEPTH 1½" • • • e e t li:4or•7WELDS ALLOWABLE SUPERIMPOSED LOADS (Lbs./Sq. Ft.), DIAPHRAGM SHEAR VALUES (q) (Lbs./L.F.) AND FLhlBILITY FACTORS (F) NUMBER OF SPANS SPAN 2.. H DECK GAGE psf & WT. psi ~4 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" ·10'-6" ~/ ~7 _ __. "-..., 1 -23t··· • · ~gg' 173 ·_ ,:t5f. -. ~ ,.'13~. • .• : -1H . 104'. -·92 : .;:; :,a:?,.,-'(:':' 14· .. ': -66 -2 261 228 202 . 151-_. , _: 132 -;: -117 -104 -. · ,·92,_ ~-4it , : ; ; ·.Z4 · 66: 3 261 228 202 151·. · 132"-. 1'17: 104 ·-9¥ -82···· .·.'74· -66 q4 1825 1785 1755 1725 1700 1680 1660 A°40 1625 1610 1600 .45 .46 .47 .48 .48 .49 I -~50-""" .5o .51 .51 .52 1.9 203s 1980 1935 1895 1855 1825 J . ....-11loo 1775 1750 1730 1715 F7 c--.. .4n 4? <11 dd AA ,..--48 ,., A7 dR AO 3½" 30.5 1 m-..... 240 183 160 · -1~:..--124' -110 '_ .--98' -· .----as--ig· -11 2 275 r--'240 212 189 ~ -l24 -110.-·:, .. :'gs· ·-as-;:-: 79 ' 71 ·a 275 i -~ 212 1~ 110 -1-24 -110 ·-· .·gs,·-· 'caa · -79 11 q4 1890 1845 t:i<......ms 1745 1715 1595 1610 1555 1635 1620 F4 .40 .41 .42 .43 .44 .44 .45 .45 .46 .46 9.z 2145 2080 ~ o ~q75 1930 1895 1860 1830 1805 1180 1150 ~7 :.5 ,o..,-n ''"':\-,,.._ _;i_g__ ,n ,In d 1 · ,i o d? A3..._ 1 %298 /261 230 205 '--l.84 i:i1 -122 10!!' ._ . stc-· -:sr:' _ 78 2 261 230 205 1Blt---... 167 152 108---'. 97, · · '·-, 87.-· -78 18 3 8 261 230 205 184 -.........i..ii1 152 138 127 87 -· -· 78 1 % 2045 1985 1930 1885 1845 18~ 1780 1750 1725 1705 1685 2 9 .32 .33 .34 .35 .35 .36 ~37 .37 .38 .38 .39 ,v ~, q7 2380 2295 2220 2155 2095 2050 2 1965 1930 1895 1865 ~ ~7 ?7 oo oo on 01 ,o 11 11 o, 1<1 1~ 20 2.3 V 1 295 260 230 205 184 155 151 1ll&-.... -9& = < a.5· -18 / 2 298 260 230 205 184 166 151 138 ~ . ·-86-· 78 16 3 298 260 230 205 184 166 151 138 117 108 . q4 2215 2140 2070 2015 1965 1920 1880 1845 1815 ~785 1760 3 5 F4 .26 .27 .28 .29 .30 .30 .31 .32 .32 .33 · q7 2635 2525 2430 2350 2280 2215 2160 2110 2065 2 --.._!9~2 F7 .22 .23 .24 .25 .26 .26 .27 28 .28 .29 ~- 36.6 ----1 -269 231-200~--t?fr'. ·15a· f35 126 101 .95 --.. 85.-.· --76 2 300 266 200-, ' 175 C 15,3':'' C 135 120 107 95 85 76 3 300 266 200 ' .. 1-75' ,--153'-135": 120-. 107' 95 . '.95<'·:· __ ·--75. Q4 2065 2025 1995 1965 1940 1915 1900 1880 1865 1850 1835 F4 .40 .41 .41 .42 .42 .43 .43 .44 .44 .45 .45 ~~ 22{~ 22~~ 21;~ 21~~ 20~g 20~~ 20~~ 201~ 19;~ 19!g 1~- 1 300 I 244 · 2i2 · 1as i63 · 144 127 113 101 9.1 81 2 300 279 247 220 163 144 127. 113 101 91-. , 81 : 3 300 279 247 220 163 144 127 113 101 . 9~ . 81 Q4 2130 2085 2045 2010 1980 1955 1930 1910 1890 1875 1860 F4 .35 .36 .37 .37 .38 .38 .39 .39 .40 .40 .40 Q7 2385 23._~~ 22~~ 2215 21;~ 21~~ 2100 2070 20~~ 2020 1995 F7 .A,1,._ .;J.L_~~>h!-.......J-~>lil---l---.JL... ~J_I, 17 ~R 1 r 300 " 300 266 237 178 157 140 125-112 .. -.10,i: , --90 2 ~3000 300 266 237 213 193 140 125 · 112· 100 -. 90 18 3 300 266 237 213 193 175 160 11-2 --100---.-. 90 . q4 2225 2170 2125 2085 2050 2020 1990 1965 1945 1925 F4 .29 .29 .30 .31 .31 .32 .32 .33 .33 .34 .34 1-----4--..l..j.,_; _ _,,,__.2 .... 6~_,,_05 25~~ 24~~ 23~~ 23~~ 22~~ 22jg 22~g 21~g 21~~ 21~~ 1 300 300 265 236 212 192 138 . "f23 110 .. 99 89 2 300 300 265 236 212 192 174 159 1-10 · -gg. 89 3 300 300 265 236 212 192 174. 159 146 135 89 q4 2455 2375 2310 2255 2205 2160 2120 2085 2055 2025 2000 F4 .24 .25 .25 .26 .26 .27 .27 .28 .28 .29 .29 Q7 2870 2765 2670 2590 2520 2455 2400 2350 2J05 2265 2230 F7 .20 .21 .22 .22 .23 .24 .24 .25 .25 .26 .76 22 1.9 20 2.3 16 3.5 4½" 1 2 -·soo .. 0,2e&-. -m · · · 2oo' ·-.-· us -, _--155 h1 -m· · · 109 -· · · _ ·97 -SL~ 300 300 .·229:-·200 175 ·155 137-1·22 -.109 ~-97 ·-'ll( 3 300 300 · 229 . · --. 200-' 125 . 155 137 ·-122 109 -· . 87 q4 2305 2265 22ao 2205 2180 2155 2135 2120 I 21Qy 2090 2015 1 g i-,..,. F4 .36 .36 .37 .37 .38 .38 .39 .39 ~ .39 .40 • ~7 2510 2460 2410 2370 2335 2305 2275 . 225a....---2230 2210 2190 F:r------.. 33 Od ,1d. 3'i .''-" ~R ..J.6. ~-~7 07 SQ 1 ;300........_ ·21s>:· m· 2tr-·t" -15s • 1e4 ~-129 n5 ·. -,:.1oa:: .-·" _93. 2 300 "--3.QO 282 • "2H --:_ i~o . '> 1§Y 146 -12s 1 1 1 1_66 ' .. 110033 __ .-__ ·_t .. 9933 3 300 ' 301J"-,-.,.,, 282 252 : ·186 · ~ · 1'46 129 -J· · t q4 2370 2325 "2~ 2250 ! 222Q,/ 2195 2170 2150 2130 l 2115 2100 F4 .32 .32 .33 ~33 1..----"34 .34 .35 .35 .35 .36 .36 Q7 2620 2555 2500 2 2410 2370 2340 2310 2280 2260 2235 C7 ?Q ?Q on ,.___ •1 oo i? oo oo ~1 o, 1 300 300 ~ 231 -203---~180 159 142 127 1t4 · · -103. 2 300 w.oo 300 272 244 1 159 142c 127 114 ., :103 a 300 300 212 244 220 h,JQQ .142 127 · 114, --:ioa · Q4 j 25?V 2460 2410 2365 2325 2290 I 22li\l ......... 2230 2205 2180 I 2160 F4 ~ .26 .27 .28 ,28 .28 .29 ~....._29 .30 .30 j .30 a7 .-, 2860 2770 2695 2630 2575 25?~ 2480 2,iim--....,. .~405 2375 i 2345 ~ 23 24 .24 .25 ,2.L_ _ .,n ?R ?7 °7 ?7 ?A 1--~----1: _ _...e.C!..1:L---1'-----c3~00'!--+-=3~00::t-.-+~3~0-oc--210 242 -1zr 1s8 ·s.:io: --12s""'-:~•-~Ht:,Jt'_,..101 2 300 300 300 270 242 219 199 -·140:: 126 -''.""··,_: ~i1;f ·.,::101,.: 1 3 _ 5 6 qF34 4 2~~i 2m 2~~~ 2~~~ 2~:~ 2~66 2m 2~~~ 2~~~ !' -~t:~_;_,,,-s,;ct{)l:.,:_ .22 .22 .23 .23 .24 .24 .25 .25 .25 I .26 26 q1 3110 3000 2910 2530 2160 2695 2540 2590 2545 2505 I 2410 "- F7 .19 .19 .20 .21 .21 .22 .22 .22 .23 .23 .24 : ""' 20 2.3 42.7 18 2.9 6 VERCO .., ,, HOPE ENGINEERING 1301 Third Ave., Ste. 300 San Diego, CA 92101 S >t -;_~ ;_ ?4!?;F ; -tpf . . l -' -'-... ----... i • ( ) ---. .. ----·-. .. . ... l JOB---------------<-2 ..... '/2'--""'-"S"""ZJ"--'-Z"'-'Z=-·-O_D_ SHEET NO. _______ OF :3 CALCULATED BY--~E~A __ DATE o4/ 05 CHECKED BY_----,,-_____ DATE ______ _ SCALE _______________ _ J·---- --1--.. . . ---. --i---- JOa ________ --1.,,.z"""o~6:.i...O~z~z~._.!,,o::=:..!o~ HOPE ENGINEERING 1301 Third Ave., Ste. 300 San Diego, CA 92101 SHEETNQ. ____________ OF + CALCULATED BY _____ .,,,~=...,A_,._ __ _ DATE Di/ p_,: CHECKED BY ____ ; ______ _ DATE ________ _ SCALE ......... ; ...••.•. : .•.... ----~ .... __ ;,_ ..... : •..... :,,,.· ... ----~--....... i,,:.... --=.: .... -. =,.;. .. . ... ....... ....... .••. ... • • ........... ·1·· ... i... . . . . -·!. . . . .. -··!·· ...... ;.... .. . .. L .. ! .. j i . ; ; ! : : . . • ' i ····· l ·····J. ... : ;· .. ~ .... L ...... : ······i-··· -1 ····; .... .:... ....... \ ....... L .. ) .... ; .. ············· ··· · ·:::.r:.-::·:··:.l: .. :.···.-=.·.: .. u .. :; .. · ...... N ... ··:·J·· t.···.~.; ...... ·.·····:·····i·: .. · ... ·:.:.:.:·······.: .. : ... :: .l .. -f ¥· Q~~\ -! ~Llyt ~ (i;tt\ (H~w !~ -iL'/Ai;2 _ftt i __ ··l···: i;: ! j ;··!·····\.. ..... i ......... \ .... ;.•r !······i···!····--1-····!······;·····:·········l·····(·····! ....... ! .. ~~r~~i ..... . ···-·-:. t~f(::~rttu;J: ff! J. L:t_-:JBr:t2 rt!l~L-' -;:?l-~:;i:'f~.: :::;~-err :-t:L:Jr-tt~-!::_J-:J -::1~::-;rr:tJ·,-:::~:~j~~:--i :f _.-·:_ --l-f E~G:;-1: 4-:~r··+-:r-r:1_--T :~t-1 J:-_r-_:-:cr-~l~: ·; J~-: ..... (,;······ "·,i······ l·· ; ; ' l : : · 1 1 ....•.... ·,····T····: ..... : ..... i.· ......... !. ..... ···!,····· I = . i . i •... !,, . .. .. ! ........ ,·. . . : ... . t . . ! -~.'. .... . . .. = •• ... ! ·············· .. r···· ,········,·······r···-r-····f· ······ .. :, ........ i, ...... .J, .. ···· : : j · : : · · : : · :.··. .. .L .... .l ...... i .. . ·r.... ........ .... . ..................... r ........ j ...... : ......................... ·:-· ... ·1· .. ····r. . . ! ........... ,. ..... ,.. ... • ••• i ..... r····"·' :_:r if~£: 3PiJiil 4~~4-f : ~·~'~;;_ •. IP -le+ ._(7, ~;, \j-" ••. ·_ ,--:-. r-· -r_-; - ..... ·)······ .: ........... :·· ...... ,. .... [·· .... !· ······i·· ····+·· .. }······ .. , ........ i. ·····; ....... , ····· l· ·········; ... . ..... , ..... :-·. .. ' i .. t .. 1······ .\-·· ...... . . · 1 : i ; . : . : i ! 1 i ; •.... ;..... l : .. ; ... _; .... : .......... i ..•.. t ..... ! .. ...... r·· .. ,·······":"················,········r ···r·· .... :·:·;:l.·.: .. ··:·::.::·:·.·.··.:·:i .. ·.·:· .. :·-.::·::·:.:··:r.···.·:.:··.:,1.:.:-::,.i·.·.· .. ::; ......... 1.... '. T.. ,··· ···: ... ·: .. . ······i·········) ·····1· ... ···l ······-l--... L ....... t·· ' :. ····j .... .L. .... T ... ( .... ·;· ··+· ... , ...... , .... .l ..... , .... ·1 ... . .. · .... ·:.::,.:L, .. :· ... :,,,:·,····.··:····.:· .. ·:··· .. :.,,r.,:····:.·;.,···. ·.·:· ... ::·.·:·.:··:.T ··· ··;········+.-.· ·:··.·'..: .:·:· ·.:·-r-:·_:·.:·:.:;.::·:::····\·········t .... ····· , ····.· .:,:··· .. ····,.i ··· · .. , ·· :·.·.: .. · .·.: ... ·:,.'· ..... :.· ..... ' ........ ;. ·· ·· ·, · ·· ·; ······ ·•··· ···: ·· ·· ;. ······· ····r ···· ········· ·(·····; ...... , ...... ;. ··1··· ·······:·········!··· .... \ ..... r-· .. <······;········;····· ' ... ; ............ L. ·····l· .. ·,,.~ ...... ~:!·;··········i········ ·····I···· ····i· ... : .. ; .... , .... i ! ! i 1 ; : ; ...... f .... ' .;, ... . . ; ..... ~ ....... J ...... :_" .. .. j ................. : ...... J. . .. ; ......... ; ......... ,i, ........ : . .. ·.. .. ..~ ....... : . .. :·· . . .. i ;. . . ; .. . ..... " .. : ... . i ; i · I · i ; ; ··· 1 ·· ; ·····i· · ····;···· ; , 1 , i ! ; : . . : . l = ...... : •..••.•. t ... .-........... ;.: ..... I ... . ... ... . . ; ..... : ...... . ···-;-...... : ······r ······i ·····-r· .. ······r-. . .. , ...... i ....... l ... ····,·· ... ,...... . .. i .. ···; ... , : . : 1 ! : ·········"!··········!. ... · .. ·· i ···· ....... \ ..... \-"" ...... : .... ··j ... . ... , .... T .... · 1 ····· r·· ... r···· ··: ... ·· ,··· ··· ·: · r· ···· t · ·, ...... !... ·· ··:-····· · i-· ... . . ~ . .. . ·:.,,: .......... L. . ..... 1 ....... ·t ..... ·.i',.: .... .~ .. . . .. ;·. ... • . . ... .... • . ...••• ~ •..... i.=. •. ; • : I . . .. ? ..•. ~ . . .... ; •. • • •. ... . . . .. ... . ,: ....... } .... " ! : ! : . : ·' .; .; . i ! ! : ~-::··--1-;_i--~_-::·•i~-i:'_:_:-_::_;_-_::_~ :;-:J_-r-: ':-:··-, ,---: . , ---·---·---; : i . ···"' l ··· ... . .! .... :-· .... ~ ........ t ........ ..i.. . ... ; . . . .. ; . ... . .......... l. ... .. . .: ... . .... ..... 1 .... ·.; ..... : ..... j. ......... 1 . ; .... t···-- ' ....................... ! .. I . --;· ..... . i ·····I .......... . I l I : : ! .... ·-....... : ....... ; .......... j ....... :,· ..... L .. . ... ... . ··•··· 'f .... -r--·· ... .... ·····: ...... ! ...... ·:·· ....... : ..... ·i·· .... + ...... ; ....... }-.... ! ... . . ···;········r·····r ··:····-r· ... ; ......... ~ ......... ; ...... : . .• .• . ...... ··j······· ... ; .. . ~ ....... ··~ .. ··t· ........ ! ... --i· ...... ,i. ••• ···1 ~ .... ·( ...... ; .... . . : : ! : .... J ........ ,! .. . ·······1 ............ ~--···· ......... ;,--··········· ... ;•·····:········;·--.. ; ........ , .... ·+·····i·······r·······:·· :--·· .. r .... : ..... "":"··· ·! . . . . .. :· ...... ~ ....... ~ ........ i . . .. t····r····r···!··· ' ; ··:·"' .. i .. , ... :., ... . j ..... f- ···:······-r····i ..... ~ ' • •••••• = •••••••• : .......... . ' , ......................... .. .; .... : .... ~ ....... . . .. '"": ......... "t·· ... . . . . ... L .. j ........ ~ .. -l .. . : .. . ~ . .. . ; ... :-·~. . ' .{ ..... ·········.········ ··· ·: ··!···· ; ·· ·r· ·····:········ ·!· ·· r······ ········,···· ··········: ·······r······· ...... r·· ; PCR05069 2200 FARADAY AV CBAD ROCKST AR SECOND FLOOR REVISE ' \ PCR £ (/k/1/v'tiJ &pN,/.,, , C,6/J;i'l!//f?. Lot# ROELCONSTRUCTIONCOINC • / # C:ftJ ~ to/' y ~ _, __, tf/ll/.o5 (l;:tu. <1. PU u,Wt.,, ~=.., ~ 0 ~FIRE- 1-/f(}) £,,,,c/Jrnn 5(7V-(..., =--==--==--===QUAL "-"', '-'/ GI _;:,It. / i TO OTHERSEWeRDISTR f--~£ M 3Keoae::6 -~ C1 ~It\ -1:!d ~ <fi~ttj-Wti "'""'"1/ =::::::::f.:::=:::~FORM _·· '-(I u[., 0'-"'Jv(L. :if-~ ~ ... $ ,-/ CI A ft ® f c._ ---=~--=t:,_ -==--::Pe&UWORKsHeET -:-: -1 ( 'y' --t----J..-8t.OGF'EESCOMPLETE J/J 7/vs -T~ ~~ Cir };ff, AM -~ L A =-----i~,,..,~-=fi:i t; I t ( u ( Qt, I J.--. I\J · Ov-' L.,,(L @) p C CL 1f!7 s: li/ 0 < ~ ,s ,.,c£/) (._ ~ s-eft--f JV ,t. ...4 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 05-09-2005 Plan Check Revision Permit No: PCR05080 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: 2200 FARADAY AV CBAD PCR Status: Lot#: 0 Applied: Valuation: 2121203700 $0.00 Construction Type: NEW Entered By: Reference #: Project Title: CB044~ .. ROCKSTAR R SEO COMPUTER G5SS-OR Applicant: TECHNOLOGY SERVICES 3981 FLOWERWOOD LN 92028 760-631-4810 Plan Check Revision Fee Additional Fees Plan Approved: Issued: Inspect Area: Owner: E QB P-1 LL C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA 92037 Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: ISSUED 04/25/2005 KG 05/09/2005 05/09/2005 $120.00 $0.00 $120.00 7765 05/09/05 0002 01 C:Gn-::::0 Inspector: FINAL APPROVAL Date: Clearance: ------- NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to.protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been niven ~ NOTICE similM to thill or as to which the statute of limit~tions h~s nreviouslv otherwise exnired. 02 .120 .()i'.) FOR OFFICE USE ONLY PERMIT or rq (SO it/ I ilj APPLICATlc:Jk PLAN CHECK NO. fCQ O"J&O CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. __________ _ Validated By . , Plan Ck. Deposit ' Date . lf-)...S' -or< Address (include Bldg/Suite #) Busines~ Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. ·Phase No. Total # of units Assessor's Parcel # Existing Use Proposed Use # of Bedrooms # of Bathrooms •.:·· •• ·:,-;,'.-"'-·.·.·.,.·:·. 1 .:;,,_:.··· Name Address City State/Zip Telephone# Fax# ij;!~f1t!~t.\~r;,f'f~<int~:~~;t'iit;f.oj~t!~~~rtr9./:;~i~~1;;::f·;~:~~er_\r {\·b~b'ti :t4½J6::~-;:::76:·i.>;fjt/: t.f f< ID Name ____, Address· City State/Zip Telephone # ;'4i)f ~ij'if1P.\;f!if"-9,Wlli~if'i:::.· -__ ,,:·.,~:::·i-:'.::/ · ·,. '°' , :-<:,: ·:.--: -,;·_ ;::::.,<·::·: \' ::·,:.;_ ,·:,.,,: __ :< :· ; :, :;;_: ·:·_:r:: :-' ·,: .. ,-_--:·,gY ,:·. Name Address City State/Zip Telephone# ~--~l~~-CQ~~IJ~ai[-9~~~;·c;~,M.r;t~~y~r.,,JXVM.Er:i~:~·,;-i ~ii~-~~·~ .,•.1:~·~1-. ·-~h:, ::.-~ :;. :-.-:::~ · .~-: 7~,:~.; -·-:. ::-, ':( .: :· . . _ '-=:_.;_: -~-~'.-~~ .... ,. ~-.'.:-:1 ·} .. ,:.~-~ ~.)111i~ -·-::·;.-:; :~-7;~:\¾? ~~1;:.:;;i,£:·:' .: ,: :j', ~ ri·;:,, i!; ·:. -,; 11~ ·~;',\1.J:,~r:~· (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemptloft!-,Any violation of Section 7031.5 by any applicant for a permit subjects }\le applicant µui. civil penalty of not more than five hundced-dollars)$500)). {ed\.v--.o .. -,. ,'<..e'.~ 391$°/\,::-(overc.,J,.>v-=-K. .-\-?-..ll~c--:;>?,l CA 9~vcJ,J' /bDb.sl-'/J"ID. Name -? . Address City State/Zip Telephone# f}l}.(-1(iO {ISJ$1SZ- State License # CA 7 / 7 D,;). :::::, License Class L .--b I City Business License # l d a O Vv ;;;._ Designer Name Address City State/Zip Telephone State License # -----~----~;?~1Wli"ij({E!i~t:C~Ml:');ij($"4, t1orF}.:\\,/-:)·: :_·-'~-;;_ ~ -.;.:··::; : .. · -:-t:_ :-:_:;:: >:-:::_:: .,;;.t.::-.-.-\ ~:.: ;::· -'.:,· _ ,, " · Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. (Iii.I I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is ~ed. My worker's compensatiop.,iosura~1e carrier and policy number are: It) · lnsuranceCompany S:{-::,,"tc_h,1..~X, PolicyNo. C:./{c./-O3-:-D~1395;xpirationDate A,A!!J 0\ d-{)E>S (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100) OR LESS) 0 rtify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' omtie ation Laws of California, . WARNING:· Failure.to-secur orkers' o pen atlon'coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000, I a dlff? e st of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees. . 1....1 ,.,_,.-~-SIGNATURE ______ ....,___,,,--____________________ DATE . -ol.;;, -v.) ;1) t· .. ow.!')i.~~h~v1Eq~tiif~[c:i:~flA, :·_ . r-iir'il·rt:: T:~::::~,,;:,-:·;~r,.:;ir?::,;;r ,:;:·'!·?: :~~;,;v ,;,,\ :·::; r ,'.{\;\ :: .. I hereby affirm that I am exempt from the Contractor's License Law for the following reason: N•.:.r ·' 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, al"!' exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions <::ode: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and ~aterials for construction of the proposed property improveme_nt. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted _with the following person (firm) to provide the proposed co,:istruction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license numberl=---~----------------'---------------------------- 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): · DATE PROPERTY OWNER SiGNATURE _____________________ _ -----------[*p\ViP.t~lf~:jT:HjsJ$i:CT-i0r{;FQR:·)voN.ifltSIQi'IVT/4l..'.B~ltQIN.G :~El!l',m·~ Qijl!Y _:_; _i,; , _ .\·:: ,,·: . , , -:: : . .-.. : · t:. · -"'-,-... ,~ • ,_ ,. • ~ • ;"4' •, Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within· 1,000 feet of tl'te outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~1W,;~15.N~taVC:1j19~~~~J?Jij9./~_qt~q·-cYi}0.",J~~:-::.::i '\.":·. ;.-.. ; ·,i , ;· __ : ~-__ \::. · =.:-:, · :··._· · .: ,,._. :· :: -.-, . -': , ___ :-.;~·-.. :::: -,: : :::. ,, \ ._, · , .,,_,,. -•'.'" I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _____ ~-------- .. -~--. /. -~· . :, -:; / ... '>-=' ., :< .. /-: I certify tt\at I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances ·and State laws relating to building construction. I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE T6 SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for exca 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by !J:i buildjp fficl I under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not com_9:1enced i!hin 180 ays from the date of such permit or If the building or work authorized by such permit is suspended or abandoned at any time after the work is commence o eriod o 180 action 106.4.4 Uniform Building Code). I ' - APPLICANT'S SIGNATURE ---./----1--,?C------------------DATE L.\ ,.. d:,~ -0...> WHITE: File ·YELLOW: Applicant PINK: Finance .I Carlsbad 04-4184 PCR05080 May 5, 2005 EsGil Corporation In <Partnersliip witli government for (}Jui{aing Safety DATE: May 5, 2005 JURISDICTION: Carlsbad D~!.Qf.NT ~ D PLAN REVIEWER D FILE PLAN CHECK NO.: 04-4184 PCR05080 PROJECT ADDRESS: 2200 Faraday Ave. SET: I (REV3) PROJECT NAME: Rockstar Office TI -Access Floor Plan Change D D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: 1 / /. Mail Telephone Fax In Person ~[l/ REMARKS: Architect of record shall-review (signed) the plans for co · ility with the project design. By: Sergio Azuela Esgil Corporation D GA D MB D EJ· D PC 4/28 Enclosures: trnsmtl.dot Carlsbad 04-4184 PCR05080 May 5, 2005 !VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Sergio Azuela BUILDING ADDRESS: 2200 Faraday Ave. BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION (Sq.Ft.) Multiplier Time Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance ... J Type of Review: D Complete Review 0 Other PLAN CHECK NO.: 04-4184 PCR05080 DATE: May 5, 2005. Reg. Mod. Rocks tar Office TI/ Access Floor TYPE OF CONSTRUCTION: V-N VALUE ($) $120.ooj D Structural Only D Repetitive Fee ~Repeats 0 Hourly 1 I Hour * $96.ooj * Based on hourly rate Comments: Esgil Plan Review Fee Sheet 1 of 1 macvalue.doc PLANNINC/ENCINEERINC APPROVALS . . . PERMIT NUMBER CB r1P..o ) 08 O DATE 'I 6. ~ J ADDRESS ?_7.oo -I/ti A:r:>Ay M f_,vv~ RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) OTHER PLANNER fis~ .. / ENCINEER ,~ Docs/Mtsforms/Planning engineering Approvats TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE FAIRE COMPLETE OFFICE BUILDING DATE r/4J5 DATE {fh 7 /4 I~ ~ Carlsbad Fire Department 05080 1635 Faraday Ave. ·'--Carlsbad,'CA 92008 ( Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan Reviewed by: 4~ Date of Report: _04_12_7_12_0_05 _______ _ Name: Technology Services Address: 3981 Flowerwood Ln City, State: Fallbrook CA 92028 Plan Checker: Job#: 05080 ------- Job Name: Rockstar Bldg #: PCR05080 -----------------=-- Job Address: 2200 Faraday Av Ste. or Bldg. No. ------------------ D Approved IZ! Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approve<:i. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to c?nstruct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications-to this office for review and approval. 1st 05080 2nd FD File# 3rd Other Agency ID Carlsbad Fire Department 1635 Faraday Ave. ·t Carlsbad, ·CA 92008 Plan Review Date of Report: _04_12_1_12_0_05 _______ _ Name: Technology Services Address: 3981 Flowerwood Ln City, State: . Fallbrook CA 92028 Plan Checker: Job Name: Rockstar Reviewed by: 05080 05080 Fire Prevention (760) 602-4660 Job Address: ·2200 Faraday Av -----------------Ste. or Bldg. No. UNDER FLOOR FIRE ALARM SYSTEM IS REQUIRED, SEE ATTACHED. Requirements Category: Building Plan Page 1 Requirement: Pending 05.19 Fire Alarm System Required A fire alarm system is required. Permits are required for the installation of all fire alarm systems. Plans must be approved by the Fire Department prior to installation. Provide a note on the plans that the fire alarm plans must be approved by the Fire Department prior to installation. Smoke/Heat Detection shall be required for space between finished floor and raised floor. This system shall be Central Station monitored. 04/27/05 STRUCTURAL CALCULATIONS FOR STRUCTURAL DE'SIGN ********************* PROJECT ROCKSTAR VIDEO GAMES CARLSBAD, CA ********************* CLIENT TECHNOLOGY SERVICES 3981 FLOWERWOOD LANE FALLBROOK, CA 92028 ********************* JHA PROJECT NO. 05-000-10 4/11/05 04/09/2005 20:13 rnoN : BllBD 9495611571 KIPPER PHONE= NO. : G163'!:G8857 .... ,9llfll,.,,..,...., Seismic TatJ&e Fe,-C81~ Of Fp Per 1997 USC equation 32-3 ~ Fp=.71~p=. 71pCa((((%)"{LL)}'-PL.ol.)4 SRSS EqLivalart (Jp) (Ca) (LL) (DL) (PIJ ('6) Oto.,ancy lmportm,ce Fadal' ~ltialf:adilier 1.5 Ha28RfoUS F~ .s 1.5 All OUll!f" LI,es: 1.0 Hoti=ntl!IIFOICI!~ (See Table 1&Q UBC 97) Uveload Dud Load Padition Load PerCBil1 af u. iot wp Fp,;=. 7'peawp(1.04)= Delledian Fedor• fFli P=(U.+DL+PL.)"+W Pecle$td Assembly Consists Of The FOJklwtng: 8asetube: c.tubt: Welds: O\dsldeC>i~ !Ill.Me Oirnension Wdh Thickness TMaS Minar DiemetGr lnsldeDiam* Length 8891!1ubeto~ CapilmfD Pedestaf Cap Finished Floor Height (l=FH) PAGE 02 Fe:b. 24 2005 11:38AM P2 0.7 1 0.44 50 psf 10 psi 10 psf 2S % 41;9 Pounds - 0,875 lft:he& o. 75 inctles 4 indle!S 0.13 tnchs 0,63 inchas 0 lnc:Ms 41nd\'es i 04/09/2005 20:13 FRll'1: BOBO 9495511571 KIPPER Pl-t,r,e NO. : 61639J8657 ................ 1ARP'fojea Roc,k9tal VideoGames STATIC LOAD -CAP TUBE Captube~ Ntt3.1,16"(0D"2-l1JA2)14 JZ(00"2+tl)A2)".5'4 Kl.Jr,:;(K=1.0) E= F~ ~ ~A.,cialstre;$ fa=5000/A AIIGWallfeA>clalae.sc Since twt < co Ohl t >= o.ce: FAF!f(1--0<'fln'\~)-Fy/ {(513+(3'1<Jlt)/(tVCCH(J<Jl~S-C~l HcMewr, &inca jtw 600011:, 8lial &iekf) load incorporates e dety,_,,.of5; Fabeconathe~ngl!bess(dtvide .,,,.. eafetyfac:lo,'ir, i1b(we equa1io1): F:t-°"(1--(0Q./r"2)1(2"Ce"2)))~ Since Fa>afa, lheCep Tubo iS OK. STATIC LOAO-DASE TUR BIIB8tUlle PR)pefti&s ~tube: A=(ODA2•lDA2;) Sq~ R={(H0"2+Hl"2)f1%)".5 ~ K-1.0 E=Modulas or SJasticity Py== ~ 141N"'~y)".5 AeluafAxial~ fs=500QfA AlloWabJeA'JofJJ Slrese Since l<llr-. Cc and t < 0.09: Fa=413"1((12123)"Fy-{312l"F~KJ11)"2)l(E"S.1416"2)) Haweii,er, dncelhe5000 lb_.. (yield)load ~ralna saretyfa::U)raf S: Fa beCGnl88 Ctlelftdtqa stress (divide by the safety fac:Cor in abava equ:lf!on): fpt=y1((FY"2t(~4*E•3.141~) Since r=a:-ta. ttl@ Bose Tube~ OK. 0.311nche5"2 0. 16 lneher2 19.05 2950)000Psl asoao Psi 127.18 16129.0 Psi 0.2 lnd'oe&"2 D.333 Inches 11.71 2.9500000 Psl 47000 P$l 111.31 PAGE 03 04/09/2005 20:13 Ftn1: BOElt) 9495611671 KIPPER PHC«e NO. ; 6163938857 " ............. . IAR. Projecl: RocJislar Vkteo Game$ SEISMIC LOAD~ BASe ruee In ord&r'fcr1he bAbe to be wilftin idfNBble rimit$ under ca,nb;ned uismic loading. thef~ ~ r1Mt be satisfied; 'BmlllJbe Prapetties Squrn tube: A=(OD"2-UY•2) Square R=({HQAZ+Hl'\2)112)".5 Square 8-(2".5)1(12"H()r(H0"4-HIA.4) ~ l=(HO\&-Hl"4)/12 kl/r-1. 7'1lr Adml.Am!S1rffl pa ~/A Actual BendJng Stress t.tomenl Arm At. Tep Of BaNblbe· Finished Floor Height (FFH) l=ff~ Panel and~ lltldQiess Fp= tb=~p"l)IS PDella Slre,s,.,. 0alledk>n"P/S ~ S= Fe={(1r3.141~E)f(236(1()/r)"2)]"'413)= AHowabl8Atia1Stmss FPl/3"((12123)•Fy-(:v2.a~(KVr)AZ)/ (E":3.141~) Sinor falFafa0.15, Fao=Fa~ AllO"Na?>le Bending Strelil$ Fb--O,f*F~-4f.3)= CtiedcAIIGWable Umlls ~~-{falFe)fFb)) <a 1.0 (f8#Faa)6{,b+POaftafF1>)<= 1.0 Sfnce lln,'ftg a'8 <.'II 1.0, SIGciube i!,; Ot<. PAGE 04 F'e.b. 24 2005 U:39AM P4 Page3 0.2 lnc:hes"2 0.333 l~ 0.0383 l,gbesA~ 0..0225 24.~ 6 inches 4.875 lnclles. 41.6 ?ounas 5592.~ Psi 101.63 41000 Psi 29500000 Psi 326914.2 P5f 32728.3 F'Si 3272ll.3 Pst 0.17 0.19 ' 04/09/2005 20:13 F'RC1'1: 90SD 9496611671 KIPPER PH:7NE NO. : 6163938857 •••••• .... u,11 1AR Prqed'; RncbtarVldeoGamee SEISMIC LOAO-CAP TUSE In mter for Iha tube to be wlrNn allOWable limits under t()l11bined Hlllimk: loading, htfollawinQ ~MB ~ be satisfied: ~Pl'Opef1iea A=t,3.141 S-(00"2-10"2))/4 Rc(00"2+10"2)" .$/4 S-(3. 1i41~10"4)~ t<llt=1. ~ft Ql)= AcCualAXleilSlress Pa: fr-PIA Actwll Bendlna Sb'8S8 MameritArmAlTopOfCaptuba: C'IJPWbe length l=captube IM;lt\-1"minimUm ~men\ Fp= fl>:M/S:lr(Fp-i)IS Fr- E"'- FCP{(12"3.141S-2'E)/~r(4/S)= Al'lowrable AXfal S1rea Fa={(1..(l<lrr)A2/~Cc-'2))-J:y/ {(~)l(lrC¢>{(t(lh)ASf(S"Cc"3)) Sffic&falFal<tl!0.15. FatR=• Alk,w;$la Elertding Sbass ~.6'"Fy14'13)= Cl18Ck Allowable Umfts (fa!Fa)-,(Ctn~1-(fa'Fe}rFb)) <= 1.0 {fa'Fa)"'(fbiFb)C:mi 1.0 Snee limlls are c:-1.0, Captube 5'l OK. PAGE 05 F'eb, 24 200S U: 400'1 PS Page-4 0.31 lnr:ha&'-2 0.158 fncl"le9"2 0.02~ lnches.A3 S2~8 0.85 280 b SSU.3 PSi 4 incfm 3 lnchea 41.84'Pounds ti089..2 P$i 36000 Psi 29SOCOO()Piu 2$1ti64~ 0.18 0.21 04/09/2005 20:13 FROM : BOSl> 9496511571 KIPPER PHJIE NO. : 61639:388S? IAR Project Rocbtar Video Gamesi TUBE TO CAP WELD· FILLET ~ Pola-MatneJrt qf Inertia O!' Weld Weldl.egSlm Wald Aree-= ,7Drleg Sb:w~Pl Polar Moment of~ J of Symetaical Ciro.4al"Weld: ~eapoeP?tY'2/12 Aea.lafBending$trass fb=,:f)"r'(capod12)1J ~ I is c:,aptUbe ie.,gtt\-1") A~~stteBS Fb=0.8"Fy-(413)= ShearS!tess k a=Fp+Sai~ Axial /Weld Arva Shar Sltea&Allowable F~ = 0.5"'Fy-(413) For Combined 8tres9ll!ls fslFs+ffllFb< 1.0 Sir,ce R>:--ft>, the~ is OK. TU9E TO ~TEWB.D-RESIITANCe AppledSelsmlcMornentet~ BWm :.-F~ illlekneY)+(l)eftaction- Ultirna!e Bnewetd Failure Moinent From Tm Report Numbll!r. SQdetJFactDr SWd=U~ Safl!!ly Factor i$ greater than 2.0 8"eweld is adaquate 0.082 lnehes 0.0868 tncties"2 0.0283 r,u:he&"-3 1389.5 Psi 3267.45 Psi 0.18 7.21$ PAGE 05 ~4/09/2005 20:13 Fm:l'1: 9:)81) 9495611671 KIPPER Pl-OE 1-(). ~ 515,.."'\',38857 . ._,. ........... . IARPto.;eet ~\ladeoGernes BASEPI.Alli BeNDING ~ ADHESIVE For lldll lOSO esame beClring arva 1.'2$' larger than baH-\111$, 0=00+1..25 ,A.~3, 1-416"(((00+1n).(.33-'2))/4 Bending "1omunt M=f~.Ddk!:otion"?) Section Modula.a ~-Mal & Berl<llng ~Bl P/~ MIS= 0all!ffl\ine PtessuteAt X X*('M,St((l,12)-((00+ 1.25)12))Jb l)eClermin8 Sending Momc,nt M X ~/~.25)"((0D+1.,20)'2))"(t,00..,,25)f-(Dn'AX Slm99IINJ X'"R~~2)12t-(Recr f::o.'Oll aaok ,..,.. 8etl4ine) KIIW}-x),a.12-<IQl:M~~-17) (T~Force llfoCk '""" e.nclhg> AllawableSehdlr,g Sln1e8 Fh=.7&-Fy*(413) N4JJl14Gendir,gft88& . S==l>*(t"2)18 ff>..-t.OOS R«fUjf1'0Th~ ~(61'MX)/(Fb"'b))".5 r Direct Stress b=1 Bending Slress PAGE El? Page6 2. 125 ,ncre. 3.48~2 206. i in-lbs 10.87 ln¢hes'l3 80.$2 Psi 19,37 Psifm 18.1 in-lbsfm 48000 P:ai 0.002817 ir,A3 6425,2ft Psi 0.049 lnehe!& ...... 04/09/2005 20:13 ~; SOBD 9495611671 KIPPER ~ MO. : 6163938857 •Ill' ....... ·"··-· tAR Pr0ject Roc:btarYideo Games BASEPLATE TO CONCREi'E BOND Bedding Moment ~rt1 +Won. p Utrit Appl',ed Stft!cs: M/(6a!;eplal9 SW316) Utltinate Faiure Mun,e.rtfor ~ FromTett~# 0 A<Snelive Men.lfadurer and type Tat8-epfale64ft Bend Une 8edioll Modulus; tweplale 8ae"316 Unit F~ SWCS: Fakn Mou..nl Bond Une Sec:tion Mad s«fety Factor 206.7 lrMbs 19.38 fbliifnA2 1001 15111 S8albond lil5 4 in 10.67 in"3 1SS.72 lblllln"2 Pmsf = Unit Falll.lte Sn9s/Urlit Applied Stress 8.04 sectlOft 1632.2 ~ RS,='1,0for ~ forceg.are lncnaGed by 'J/1.0 SareeyFacfloris~ll'I-, a.oMhaweis~ Celculaaons~ Da1e -i./2-~~- CtlltbJd~-----------oace ___ _ -Rden;,,--.oeg -19Sf7 lJ{rifonn Building Cod@!. -Sptd.fordesign c:ICclt,I-Foamed S.... Structural ,nen,bels (AISI) PAGE 08 Y.,,2-S:o5 -tfla;J(ffeL'to ~ w/~ ctlfe!ll-~ c30<{1.-{1f'-/ rM-°'1@¥ '13 ~ -70 j-/4/'-(, lflf~) a;ty €) fc~ s-/,i ! c,{" ~JU ()w J...i{L... e)(Jcf2_ W'1 ~~~¼ S ~ /ps -;:-'0 s ~ ---- To PCR05080 2200 FARADAY AV CBAD ROCKSTAR RAISED COMPUTER ACCESS FLOOR PCR Lot#: TECHNOLOGY SERVICES ..,,, SCM0oLR:>RM J.---CFDFGMf ~ PE&M~ .J ILDGF&sC0MA.eJe PLNJCORR . ENGCORR EIGILCORA FIRECORR