Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; 150; CB141263; PermitCity of Carlsbad 09-25-2014 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB141263 Building Inspection Request Line (760) 602-2725 Job Address: 2200 FARADAY AV CBADSt: 150 Permit Type: Tl Sub Type: INDUST Status: ISSUED Applied: 06/06/2014 Entered By: LSM Parcel No: 2121206000 Lot#: 0 Valuation: $1,299,200.00 Construction Type: 3B Occupancy Group: Reference# Plan Approved: 09/24/2014 Issued: 09/24/2014 Inspect Area PB Plan Check #: Project Title: NETGEAR-35,000 SF Tl TO INCLUDE NEW PARTITIONS/CONFERENCE ROOMS/COPY AREAS AND NEW A3 ASSEMBLY SPACES. MINOR STRUCTURAL INFILL OF EXISITNG STAIRCASES Applicant: RICHARD PLATT 3110 WOODCREEK DR DOWNERS GROVE IL 60515 331-251-2726 Building Permit Add'I Building Permit Fee Plan Check Add'I Building Permit Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedidted Plan Review $4,586.12 $0.00 $3,210.28 $0.00 $0.00 $272.83 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00. $0.00 $0.00 $0.00 $0.00 $0.00 $48.00 $1,015.00 Total Fees: $9,528.24 Total Payments To Date: Owner: RO F II FARADAY LL C C/O REGENT PROPERTIES 11990 SAN VICENTE BLVD #200 LOS ANGELES CA 90049 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee Green Bldg Standards Plan Chk TOTAL PERMIT FEES $9,528.24 Balance Due: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $299.00 $43.00 $54.01 $0.00 $0.00 $0.00 $0.00 ?? ?? $9,528.24 $0.00 Inspector: FINAL APPROVAL Date: 1-Zf--f,S' Clearance: _____ _ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING 0BUILDING OFIRE 0HEALTH 0HAZMATIAPCO «1~) Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov Plan Check No. ~ 14 I ::lv3 °¥ CITY OF CARLSBAD· JOB ADDRESS CT/PROJECT# LOT# PHASE# #OF UNITS # BEDROOMS tJ/;4 # BATHROOMS DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ~4.1r.t/-f"~!, u I f.lltsl-l"J 1 s/Q,y ,ff.let fl~(~A1~ • AJ,tw c,uhkl{h,, fU(lh'j I Cd/JY 4rtt,~ 1 'jfrv ch,rqf 1'i-i /.// o I y{., -e ,i'Hl~5 'i /-c1l' "'Se . ,~Jv,(,_t7 Ct .. J htlil Est. Value t Plan Ck. Deposit Date C, l.D l SWPPP he "11 JJa~-rtAkJ pr.,,-;./Jl1H, o1r,/ A-'J As~"''r ,;t1<tli. 111c~or ,~ J5J1011 5F -~ OCC. GROUP BA- EXISTING USE FIRE SPRINKLERS YES.0NoD APPLICANT NAME PLPrrr ADDRESS STATE 1-L. ZIP 6~515 CITY ZIP COOl FAX PHONE EMAIL EMAIL ADDRESS CITY CITY ZIP 6t5/5 PHONE PHON EMAIL EMAIL STATELIC. # STATELIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: I hereby affirm under penalty of peijwy one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' c mp ens ion, as required. by Secti 3700 of the Labor Code, for the performance o the work for which ~e it is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. 1 'ttA-(., Policy No. W () f O / Expiration Date ________ _ This section need not be completed if the permit is fo one hundred dollars ($100) or less. D Certificate of Exemption: I certify that in the performance of the work for which this permitis issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as p o ided for In Section 3706 of the Labor code, interest and attorney's fees, /i5 coNTRACTORSIGNATURE 15:?AGENT DATE Ir ~~/3 I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvementis sold within one yearof completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. ;g]ves 0No 2. I !h2::'.,e / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): W f: t6 €--4/t 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone / contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): Ji5 PROPERTY OWNER SIGNATURE EIAGENT DATE Ir ~ J :~~~fvo.~oo-~roo~-oo~~~~i~11--~rr~¢0,f1{# · &,fl_~~d~_ :Pro_~tt : ./ ---· ~ · <: -· Is the applicant or future building occupant required to submit a business pla~utely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes (.,!:9. Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air QIWi/,Y management district? Yes @ Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes Qlpl IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ' ,, ' ~ ' ,' ' I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name µ (A · Lender's Address /J / ;4 I certify that! have read the application and state that the above infonnation is correct and that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carisbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pennlt is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every pennit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such pennit is not commenced within 180 days from the date of such pennit or if the building ornork authorized by such pennit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unifonn Building Code}. ,/!S APPLICANT'S SIGNATURE /Yt1_ DATE o-~-IV , STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCY (Commercial Projects O nlyj Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. I CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) ASSOCIATED CB# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION ,.€5 APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB141263 Type: Tl _D!3:~~-. -· Inspection Item ____ _ 01/27/2015 89 Final Combo 01/27/2015 89 Final Combo 01/21/2015 85 T-Bar 01/21/2015 85 T-Bar 12/09/2014 85 T-Bar 12/05/2014 85 T-Bar 12/03/2014 85 T-Bar 11/19/2014 17 Interior Lath/Drywall 11/14/2014 84 Rough Combo 11/13/2014 14 Frame/Steel/Bolting/Weldin 11/05/2014 89 Final Combo 10/29/2014 85 T-Bar 10/17/2014 85 T-Bar 10/06/2014 17 Interior Lath/Drywall 09/26/2014 84 Rough Combo Wednesday, January 28, 2015 INDUST Inspector ---~ct RI PB AP RI PB AP PB AP PY NR PB NR PB AP PB AP PB NS PB NR PB AP PB NS PB AP PB CA NETGEAR-35,000 SF Tl TO INCLUDE NEW PARTITIONS/CONFERENC Comments COF/ STE 150/ NETGEAR Page 1 of 1 £' . ,, ,./~4'-> ~ CITY OF CARLSBAD Building Division INSPECTION RECORD @ INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB CB141263 2200 FARADAY AV 150 NETGEAR-35,000 SF Tl TO INCLUDE NEW PARTITIONS/CONFERENCE ROOMS/COPY AREAS AND NEW A3 ASSEMBLY SPACES. MINOR STRUCTURAL INFILL OF EXISITNG STAIRCASES @ CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION ' Tl INDUST @FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Building AND CLICK ON "Request Inspection" DATE: Lot#: RICHARD PLATT . ~ECORDCO!PV IF "YES" IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF-FAX TO 760-602-8560, EMAIL TO BLDGINSPECTIONS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE., CARLSBAD, CA 92008. BUILDING INSPECTORS CAN BE REACHED AT 760-602-2700 BETWEEN 7:30 AM -8:00 AM THE DAY OF YOUR INSPECTION. ·• --Required Prior to Requesting Building Final If Checked YES Date Inspector Notes Planning/Landscape 760-944-8463 Allow 48 hours --CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm ... Fire Prevention 760-602-4660 Allow 48 hours ----- Type of Inspection CODE:# BUILDING Date Inspector #11 F0UNDATI0~ #12 REINFORCED Sl'~EL ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 D ELECTRIC SERVICE O TEMPORARY D GROUT D WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS CODE:# MECHANICAL #ll C0U:JMN F00T.INGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME O FLOOR D CEILING #44 D DUCT & PLENUM D REF; PIPING #15 ROOF SHEATHING #43 HEAT-AIR C0ND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL ----,-----__,.·-+------If-------; #16 INSULI\TI0N CODE:# COMBO INSPECTION #18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWALL #82 DRYWALL,EXT LATH, GAS TES (17,18,23) #51 POOL EXCA/STEEL/B0ND/FENCE #83 ROOF SH EATING, EXT SHEAR (13,15) #55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL #85 T-Bar (14,24,34,44) c·oDe: # PLUMBING Date FINAL OCCUPANCY (19,29,39,49) #22 D SEWER & BL/CO D PL/CO Date #21 U~DERGR0UND DWASTE D WTR #24 TOP OUT D WASTE D WTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 D GAS TEST OGAS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S 0V~RHEAD VISUAL ,(.,, #28 SOLAR WATER · A/S OVERHEAD HYDROSTATIC #29 FINAL A/SFINAL CODE:# STORM WATER F/AR0UGH-IN #600 PRE-C0NST~UCTiON MEETING F/AFINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 N0TICETO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEf. WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAt WARN.ING MEDICAL GAS FINAL .·.· cc:,1-tnnn1? SEE '3ACK FOR S?ECIAI. t•OTES ., Section 5416. Health and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a construction job site. The water closet shall consist of a patented chemical type toilet. (b) For the purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress. (c) A violation of this section shall constitute a misdemeanor. All construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector. DATE ADDITIONAL NOTES ~ ~' ,.+'.~·. ~~-. ~ CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT 8-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. ProjectiPermit: tiff 6. £A~ Project Address: '2'2-oo p~A.DAV Au'=, drtc...5.BA-D, CA A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder IJ. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Pleaseprint,__ __ J2ct4,-J<: &-lJ.. (qe'1~S (First) (MI) (Lase) '-<_; ---- Mailing Address ...... :_l-='_,_7_,o"-'o"'--_ _,_()'-'"'~l.....,{;;.c.;Y<---U_,_.;;.~_w __ Sk.....;_'--2_Z._o-;7__;cL'--'--Q _M_, ~-"'-'-"'-''°''-'--;f--' __ C.'--A'----=--'-()=63:c...:~ Email· =J :;-6..,-"---'(!...___li..c..,s..__a.;;.i_4,........=55:a....;:;__o -=--C'-1«;."-"./r-'-'s'-'.--"-c...,_,..,-, ______ Phone: Zit./--5 '2. "2.. -Oo 3o I am: DProperty Owner OProperty Owner's Agent of Record OArchitect of Record )$"Engineer of Record State of California Registration Number· 5E. 51 !; 2, Expiration Date: l 3/1 S: AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknoyiue~ge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, co~strucijon materials testing and off-site fabrication of building components, as prescribed in the statement of special inspectio~ note~ .9n the app::~flSclnd, as required by the California Building Code. Signature· ·:---:/(.,qj_,,7 Dam --cYl / le't / J.._oit-- B. CONTRACTOR'S STATEMt:NT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor / builder I owner-builder. Contractor's Company Name: _ _-=;A~t'i ... C.=o ..... /;_,M .... "--v~r-'-'rg'-'-ff-----------Please check if you are Owner-Builder :I Name: (Please print) __ --'-18...,t'.,,.,.k1,,1-tr....,J _______ --'<:r,,__ ________ --L..Jpk'""'q...;.ft.,___ ____ _ (First) I) (M I I n bi (Last) Mailing Address: 31/ 0 \Jua,lc.,ec k /Jr Ut1111hf/) rove JL &05/s Email: __ [_0,...,,./&t"-{-H,___....._@ ____ _.,._(;lfi_l-"'-"O~-"--=''tf...,..1-· ~(._04A _____ Phone: 3 3 / ;;s /-J ?JI I (?]!7 l.l!ft I"/"} !!'1 State of California Contractor's License Number: __ ___,fl._.,_(L-"--"l/'-'j_..__:t._..._ ___ Expiration Date: __ ,,..~_L-l_..,t/'-~:....11 fL-- • • • • • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will provide a final report/ letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. J!l~./J, Signature.__: ------WU~---{t _________ Date: __ ~1/li-'--"-'~Ji--'-/__.'f __ _ B-45 Page 1 of 1 Rev. 08/11 Carlsbad 14-1263 9/22/14 DATE: 9/22/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-1263 EsGil Corporation In <Partnersnip wit/i, government for <Bui{aing Safety SET: IV PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Netgear Office Remodel D APPLICANT D JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. C8J The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: 1:8:1 EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Email: Fax#: REMARKS: A. The exit signs clouded in red on sheet LS1 .2 must be included on the c~y set of plans. B. The structural sheets S-1.0, S-2.0 & S-3.0 at the back of the approved plans from EsGil must be included with the latest set of City plans to make a 2"' set of approved pla~. By: Chuck Mendenhall Enclosures: EsGil Corporation D GA D EJ D MB D PC 9/15/14 EsGil Corporation In (J!artnersliip witli qovemment for <.Bui{aing Safety DATE: 9/2/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-1263 PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Netgear Office Remodel SET: III LICANT IS. N REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Richard Platt 3110 Woodcreek Dr,, Downers Grove, IL 60515 D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Richard Platt Telephone#: (331) 251-2726 Date contacted: o/ · 2, (bye() Email: rplatt@arcomurray.com Fax #: .Q__Mail')C Telephone\J t-1\ Fax In Person D REMARKS: By: Chuck Mendenhall EsGil Corporation D GA D EJ D MB D PC Enclosures: 8/25/14 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 14-1263 9/2/14 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font AND CAPS are current. 2. The plans show you intend to remove a stairway from the 2nd floor. Provide a detailed exit plans for the 2nd floor showing that one exit stair is sufficient for the 2nd floor. The response directs me to the 2nd floor exit plan on LS1 .1. From what is shown the occupant load of this floor exceeds 29 and the common path of travel exceeds the 100ft. See CBC Tables 1014.3 and 1021.2(2). This floor level requires two code complying exits. THIS ITEM STILL APPLIES. THE COMMON PATH OF TRAVEL AT THE REVISED 2ND FLOOR EXCEEDS 100 FT. THIS DOES NOT COMPLY WITH THE CODE. CBC 1014.3 & 1021.2(2). 8. Where special inspection is required, as listed on sheet S-3.0, the designer shall complete the city's "Special Inspection Agreement" and submit to the city prior to permit issuance. This must be completed and returned to the city prior to permit issuance. THE STRUCTURAL PLANS SHEETS 51 .0 THRU 53.0 WERE NOT INCLUDED WITH THE PLANS, THERE WAS NO ATTACHED SPECIAL INSPECTION FORM INCLUDED WITH THE PLANS. PLUMBING AND MECHANICAL CORRECTIONS + JURISDICTION: Carlsbad DATE: 9/2//2014 PLUMBING (2013 CALIFORNIA PLUMBING CODE) A. THE UPDATED PLANS NOW CONTAIN PLUMBING SHEETS P1.0 THRU P3.0. SHEET P1 .0 SHOWS REPLACEMENT FIXTURES AND SOME NEW PLUMBING LINES WITH 'BFP' AND 'DCV'. WHAT IS THE PURPOSE OF THESE NEW PLUMBING LINES? WHAT ARE THE SYMBOLS 'BFP' AND 'DCV' LISTED ON SHEET P1 .0. THESE PLUMBING SHEETS WERE NOT A PART OF THE ORIGINAL PLAN SUBMITTAL Carlsbad 14-1263 9/2/14 NOTE: All other previous plumbing and mechanical items are OK. END OF RECHECK To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In (J?artnersliip witli government for (]Jui(aing Safety DATE: 8/8/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-1263 PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Netgear Office Remodel SET: II CJ APPLICANT ~URIS. CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a c9mplete recheck. JZI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. JZI The applicant's copy of the check list has been sent to: Richard Platt 3110 Woodcreek Dr,, Downers Grove, IL 60515 D EsGil Corporation staff did not advise the applicant that the plan ch~ck has been completed. JZI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Richard Platt Telephone#: (331) 251-2726 /Date contacted: 25( E) (by: Y'A-Email: rplatt@arcomurray.com Fax #: ~Mail Telephone Fax In Person D REMARKS: By: Chuck Mendenhall EsGil Corporation ~ GA D EJ D MB D PC Enclosures: 8/4/14 9J20 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 . -.- Carlsbad 14-1263 8/8/14 1. 2. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. The new partition construction is shown on sheet A4.1. Where the wall does not extend to the structural floor or roof detail the method of providing lateral support at the top of the wall to resist the code required out-of-plane load of 5 PSF. See detail P2 on sheet A4.1 and detail the lateral support for the bottom of the trusses in detail P1 on sheet A4.1. The response directs me detail 2/A4.2. Specify in detail 2/A4.2 the size and spacing of the bracing. Max spacing is 6'-0" O~!~e-code-requireEl-5-P-SE_a~~ to the wall. ------.... ~ The plans show you intend to remove a stairway from the 2nd floor. Provide a detaH d exit plans for the 2nd floor showing that one exit stair is sufficient for the 2nd floor. The response directs me to the 2nd floor exit plan on LS1 .1. From what is shown t e occupant load of this floor exceeds 29 and the common path of travel exceeds the 100ft. See CBC Tables 1014.3 and 1021.2(2). This floor level requires two code complying exits. _,// / ecial inspection is required, as listed on sheet S-3.0, the_designersnarcomplete the city's "Special Inspection Agreemen an so mi -totfie city pr1or to permit issuance. This must be completed and returned to the city prior to permit issuance. END OF ARCHITECTURAL RECHECK To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. . . "( Carlsbad 14-1263 8/8/14 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLUMBING AND MECHANICAL CORRECTIONS + JURISDICTION: Carlsbad + PLAN REVIEW NUMBER: 14-1263 PLAN REVIEWER: Glen Adamek DATE: 8/8/2014 SET: II GENERAL AND ARCHITECTURAL PME ITEMS 1. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. PLUMBING (2013 CALIFORNIA PLUMBING CODE) 7. No response provided. Provide calculations to show compliance with CPC Section 422 & Table 422.1. (Minimum Plumbing Facilities). The new Conference Rooms, Flex Room, Training Room, and Break Room require more plumbing fixtures than old office areas. MECHANICAL (2013 CALIFORNIA MECHANICAL CODE) 17. Correct the required outside air amounts for the Training Room, Flex Room and Break Room on the MECH-3C form. The number of people used in the calculations are too low. Also, provide calculations for each of the Air Handler units serving the VAV boxes. Show the outside air amounts for Air Handler units as per the corrected MECH-3C calculations. Please provide complete corrected MECH-3C forms showing each of the VAV units (and each separate room) and the rebalancing of the air handler units for the required mechanical ventilation rates for the new or revised conditioned spaces. Coordinate the mechanical plans and schedules and the Title 24 outside air design. Title 24 121(b)2 & (d). The MECH-3C form on sheet M6.1 does not show the different occupant loading for each of the separate rooms. The MECH-3C form does show include the larger ventilation rates for each of the Conference Rooms, Flex Room, Training Room, and Break Room. All requires more outside air than shown on MECH-3C form provided. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. EsGil Corporation In <Partnersfiip witfi <}overnment for <Bui{aing Safety DATE: 6/16/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-1263 PROJECT ADDRESS: 2200 Faraday Ave. PROJECT NAME: Netgear Office Remodel SET: I D APPLICANT Z:1URIS. -D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [:gj The applicant's copy of the check list has been sent to: Richard Platt 3110 Woodcreek Dr,, Downers Grove, IL 60515 D · EsGil Corporation staff did not advise the applicant that the plan check has been completed. [:gj EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Richard Platt Telephone#: (331) 251-2726 Date contacted: Le ( t+ (by~ Email: rplatt@arcomurray.com Fax #: /~M£i T~hone._. Fax In Person D '""' .) REMARK . By: Chuck Mendenhall EsGil Corporation [ZI GA D EJ D MB D PC Enclosures: 6/9/14 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 14-1263 6/16/14 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 14-1263 OCCUPANCY: B,A3 TYPE OF CONSTRUCTION: III B ALLOWABLE FLOOR AREA: no change JURISDICTION: Carlsbad USE: office TI ACTUAL AREA: 18,000 approx. TI STORIES: 2 HEIGHT: no change SPRINKLERS?: Yes REMARKS: OCCUPANT LOAD: 180 approx. ( New Areas) DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 6/16/14 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/9/14 PLAN REVIEWER: Chuck Mendenhall This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regl!lations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 14-1263 6/16/14 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. The new partition construction is shown on sheet A4.1. Where the wall does not extend to the structural floor or roof detail the method of providing lateral support at the top of the wall to resist the code required out-of-plane load of 5 PSF. See detail P2 on sheet A4.1 and detail the lateral support for the bottom of the trusses in detail P1 on sheet A4.1. 2. The plans show you intend to remove a stairway from the 2nd floor. Provide a detailed exit plans for the 2nd floor showing that one exit stair is sufficient for the 2nd floor. 3. Note on the plans at the door schedule on sheet 01 .1: "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort." Section 1008.1.9. In lieu of the above, in a Group B, F, M or S occupancies you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." This signage is only allowed at the main exit. Section 1008.1.9.3. 4. Each door in a means of egress from an occupancy of Group A having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. Section 1008.1.10. This applies to the Break Rm ( Rm 154) exit doors 5. The Break room #154 has an occupant load greater than 50 and is classified as an A-2 occupancy. Provide a 1 HR fire barrier between the A-2 occupancy and the Office occupa11cy per CBC Table 508.4. 6. Detail on the plans the 1 HR fire barrier wall surrounding the Break room. Show the walls extending to the roof or floor system above. 7. Doors opening into the Break Rm must be¾ fire rated per CBC Table 716.5. 8. Where special inspection is required, as listed on sheet S-3.0, the designer shall complete the city's "Special Inspection Agreement" and submit to the city prior to permit issuance. • NON-RESIDENTIAL GREEN BUILDING STANDARDS Carlsbad 14-1263 6/16/14 9. Expand the Green code list of items found on sheet CAL 1.1 & CAL 1.2 to include: Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. • ELECTRICAL 10 Show on the electrical lighting plan, E2.1, the location of the exit signs as shown on the architectural exit plan sheet LS1 .1. END OF ARCHITECTURAL & STRUCTURAL REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. + PLUMBING AND MECHANICAL CORRECTIONS + JURISDICTION: Carlsbad + PLAN REVIEW NUMBER: 14-1263 PLAN REVIEWER: Glen Adamek DATE: 6/16/2014 SET: I GENERAL AND ARCHITECTURAL PME ITEMS 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. Please provide the upper floor level floor plans for changes for removing the stairway at Reception/Waiting Room. Please include the revised upper floor exiting plan. Also, provide second floor mechanical plans for the additional new second floor area shown on sheet S-2 for floor fill-in. 3. Provide data on the proposed hazardous materials to be stored and used. Present the description of the hazardous materials in a format that coincides with the material classifications found in CBC Tables 307.1(1) and 307.1(2). a) Clearly show the types of hazardous materials being stored or used. Provide a list of the proposed hazardous materials; include the material safety data sheets (MSDS), if applicable. b) Clearly show the amounts for each type of hazardous material to be stored and in use. Carlsbad 14-1263 6/16/14 c) d) Clearly show the locations in the building where each type of hazardous material is being stored or used. Note: If hazardous materials are present in any amount, forward this information to the mechanical designer for design compliance with CMC Chapter 5. PLUMBING (2013 CALIFORNIA PLUMBING CODE) 4. Please provide plumbing plans and calculations for the proposed changes in the plumbing systems. No plumbing plan provided for the proposed changes. 5. Floors shall slope to the floor drain(s) location(s). Please detail on the architectural floor plans. CPC 418.5 6. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping, the drain, waste, and vent piping, gas piping, and the roof drains. 7. Provide calculations to show compliance with CPC Section 422 & Table 422.1. (Minimum Plumbing Facilities). The new Conference Rooms, Flex Room, Training Room, and Break Room require more plumbing fixtures than old office areas. 8. As per the California Green Building Code, new or relocated water closets and associated flushometer valves, if any, shall use no more than 1.28 gallons per flush, and shall meet performance standards, established by the American National Standards Institute Standard A112.19.2, H & S Code, Section 17921.3(b). Please correct all the proposed water closets. 9. As per the California Green Building Code, new or relocated urinals and associated flushometer valves, if any, shall use no more than 0.5 gallon per flush, and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code, Section 17921.3(b). 10. Provide complete water line sizing calculations: Include the water pressure, pressure loss calculations, water demands, and the developed pipe lengths for the proposed new plumbing fixtures. CPC 610.0 or Appendix 'A'. 11. All water closet seats, except those within dwelling units, shall be of the open front type or have an automatic seat cover dispenser, as per CPC, Section 411.2.1. 12. Drinking fountains are required by CPC Table 422.1 for this occupancy type (if the occupant load exceeds 30. CPC 415.2). Review the requirements of this Table and provide as necessary. Note: If food is consumed indoors, water stations may be substituted for drinking fountains. CPC 415.2 13. Hot water is required for public use washing fixtures such as lavatories. Please provide. CPC 601.1. 14. Describe the method of compliance for temperature limitations for the public use lavatories (limited to 11 0 degrees). Note: The water heater thermostat may not be used for compliance with this Code section. CPC 421.2. Energy Standards 11 0(C)3. 15. Provide the following information concerning the existing water heater: Carlsbad 14-1263 6/16/14 a) b) Show water heater type, size, and location on plans. CPC 501.0 Show that water heater is adequately braced to resist seismic forces. Provide two straps. One strap at top 1 /3 of the tank and one strap at bottom 1 /3 of the tank. CPC 507.2 c) Show P & T valve on water heater and detail the drain routing to the exterior. It may not be installed upwards from the valve. CPC 608.5 16. Provide drain, waste and vent plans. MECHANICAL (2013 CALIFORNIA MECHANICAL CODE) 17. Please provide complete corrected MECH-3C forms showing each of the VAV units (and each separate room) and the rebalancing of the air handler units for the required mechanical ventilation rates for the new or revised conditioned spaces. Coordinate the mechanical plans and schedules and the Title 24 outside air design. Title 24 121(b)2 & (d). The MECH-3C form on sheet M6.1 does not show the different occupant loading for each of the separate rooms. The MECH-3C form does show include the larger ventilation rates for each of the Conference Rooms, Flex Room, Training Room, and Break Room. All requires more outside air than shown on MECH-3C form provided. 18. Clearly show the type of materials to be exhausted from the 3D printer. 19. Detail exhaust ventilation system compliance with CMG Chapters 5 & 6. a) Detail the required make-up air as per CMG 505.3 b) Detail the exhaust outlet clearances as per CMG 504.5 (Environmental) & CMG 506.9 (Product conveying). c) Clearly show the duct materials are suitable for the intended use. CMG, Section 506.1 d) Clearly show the exhaust duct material and gage used for each duct size. CMG Tables 506.2(1) and/or 506.2(2) e) Separate and distinct systems shall be provided for incompatible materials. CMG 505.1.1 f) Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces. CMG 505.1 g) Detail minimum duct conveying velocities as per CMG 505.2 and Table 505.2 h) Detail duct cleanouts as per CMG Section 506.3 i) Detail required explosion venting of dust collection systems as per CMG 506.4 j) Detail duct support as per CMG 506.5 & 603.5 k) Detail fire protection as per CMG 506.6 I) Detail clearances from combustibles as per UMC 506.7 m) Detail protection from physical damage as per UMC 506.8 & 603.4. 20. On the mechanical plans clearly show the limits of ceiling space used as duct or plenum. CMG 602.2. Then address the following on the plans: f ' • ' Carlsbad 14-1263 6/16/14 a) Specify that all combustible materials exposed within the plenum space must comply with CMC Section 602.2. Flame-spread index of not more than 25 and a smoke- developed rating of not more than 50. b) Environmental duct systems under positive pressure and/or product-conveying duct systems shall not extend into or through ducts or plenums. CMC Sections 504.0 (Environment) & 505.0 (Product conveying). The 3D printer exhaust duct may not be run within the ceiling plenum space. Please correct. c) Clothes-dryer moisture-exhaust ducts under positive pressure shall not extend into or through ducts or plenums. CMC Section 504.3 d) Add the following three specifications to the mechanical and electrical plans: "Electrical wiring methods to be installed in the plenum areas shall comply with NEC 300-22(c)1", "Nonmetallic pneumatic tubing must be listed and labeled for use in plenum areas", and "Recessed speaker enclosures and light fixtures shall be listed and labeled for use in plenum locations". Detail the primary and secondary mechanical condensate waste design: Pipe sizing, routing, and termination areas. CMC 312.5 & CPC 807.0 21. Please provide cut-sheets and installation instructions for the proposed 3D printer shown in the detail 10 on sheet M3.0. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 14-1263 6/16/14 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED-BY: Chuck Mendenhall BUILDING ADDRESS: 2200 Faraday Ave. PLAN CHECK NO.: 14-1263 DATE: 6/16/14 BUILDING OCCUPANCY: B. A3 TYPE OF CONSTRUCTION: III B BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: El ORepetitive Fee ..,. Repeats Comments: AREA Valuation ( Sq. Ft.) Multiplier 18000 City Est By Ordinance .... .,,. Complete Review D Other 0 Hourly EsGil Fee Reg. VALUE Mod. D Structural Only ------ilHr.@ • ($) 1,299,200 1,299,200 $4,586.121 $2,980.98! $2,568.231 Sheet 1 of 1 macvalue.doc + ~ «~~ ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANS MITT AL DATE:07/02/14 PROJECT NAME: NETGEAR PLAN CHECK NO: 1 SET#: ADDRESS: 2200 FARADAY AVE VALUATION: $1,299,200 Tl Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov PROJECT ID: CB14-1263 APN: This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: KATHLEEN LAWRENCE 07/02/14 A Final Inspection by the Division is required Yes ./ No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: RPLATT@ARCOMURRAY.COM You may a/so have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 .. 760-602-2750 760-602-4665 Chris Sexton I' Kathleen Lawrence Ruan J 760-602-4624-760-602-27 41 760-602-4863 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros ndy V1f m1f! 760-602-4-675 760-602<~773 760-602--.!-662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov Do1:1inic 7€,0-1302-4-6S4 Dominic.Fieri@carlsbadca.gov Remarks: «~ ~ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for C814-1263 Date:07/02/14 Project Address: 2200 FARADAY AVE Tl Project Description: ENGINEERING contact: Kathleen Lawrence Phone: 760-602-27 41 [~] RESIDENTIAL INTERIOR 0 RESIDENTIAL ADDITION <$20,000> [] CARLSBAD PREMIER OUTLETS [] OTHER: --PRE-FAB SHADE CANOPIES APN: Valuation: $1,299,200 Email: kathleen.lawrence@carlsbadca.gov Fax: 760-602-1052 GZJ TENANT IMPROVEMENT 0 PLAZA CAMINO REAL 0 COMPLETE OFFICE BUILDING r··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··, . OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: KATHLEEN LAWRENCE DATE:07/02/14 REMARKS: NO ADDTL FEES NO CHANGE IN USE Notification of Engineering APPROVAL has been sent to RPLATT@ARCOMURRA Y.COM via EMAIL Oh 07/02/14 -··-··-··-··-··-··-··-··-··---··-··-··-··-··-··-··-··-··-· E-36 Page 1 of 1 REV 4/30/11 «~>, ~ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 6/9/14 PROJECT NAME: T.I. PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.e.ov PLAN CHECK NO: CB141263 SET#: ADDRESS: 2200 FARADAY AV #150 APN: [Z] This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required D Yes IZ] No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: rplatt@arcomurray.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: D D D PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton D Kathleen Lawrence D Greg Ryan 760-602-4624 760-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz D Linda Ontiveros D Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D D Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: NO ROOF MOUNTED EQUIPMENT PROPOSED AS PART OF THIS PERMIT «~ ¥ CITY OF CARLSBAD DATE: 09.22.2014 PLAN CHECK NO: 3 SET#: 1 ., PLAN CHECK REVIEW TRANSMITTAL BUILDING DEP'f,, cf~Pni{ & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov PROJECT NAME: NETGEAR PROJECTID:CB141263 ADDRESS: 2200 FARADAY AV STE 150 APN: 212-120-41 ~ This plan check review is complete and has been APPROVED by the FIRE Division. ·By: G. RYAN A Final Inspection by the FIRE Division is required IZ! Yes D No D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: D Chris Sexton 760-602-4624 Ch ris.Sexton@carlsbadca.gov D Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov D Remarks: See Attached D Kathleen Lawrence 760-602-27 41 Kathleen.Lawrence@carlsbadca.gov D D Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov ~ Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov D CindyWong 760-602-4662 Cynthia.Wong@carlsbadca.gov D Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov · Carlsbad Fire Department Plan Review Date ·of Report: Name: Address: Permit#: Job Name: Job Address: Requirements Category: Tl, INDUST 09-23-2014 RICHARD PLATT 3110 WOODCREEK DR DOWNERS GROVE IL 60515 CB141263 NETGEAR-35,000 SF Tl TO 2200 FARADAY AV CBAD St: 150 Please review carefully all comments attached. Conditions: CITY OF CARLSBAD FIRE DEPARTMENT-APPROVED: BUILDING DEP'f. COPY Reviewed by: __ 4 __ 4_~_ THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. At or prior to Final Fire and Building inspection an Emergency lighting facilities test shall be conducted by CFO personnel during pre-dawn or dusk hours when ambient light is at 0.00 Lux or 0.0 Foot-candle. This test shall be conducted to test the initial loss of power reading of illumination that is at least an average of 1 foot candle (11 lux) and a minimum of 0.1 foot-candle (1 lux) measured along the path of egress at the floor level. And tested after 60-minutes to 0.6 fc (6 lux). Failure to provide sufficient lighting in egress aisles, corridors, exit enclosures, exit passageways and stair enclosures is the AOR's responsibility. CFC Ch. 10, Sec. 1006. Entry: 09/23/2014 By: GR Action: AP .!:'age 1 or 4 RECOMMENDATION FOR APPROVAL Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Richard Platt -Arco Murray PROJECT NAME: NETGEAR BLDG. DEPT COPY Checked by: Daryl Kit James Date: 9/11/2014 JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2200 Faraday Ste150 PROJECT DESCRIPTION: CB141263 Approx. 35,000cn Renovations of existing 1 story office area including new non-rated partitions and finishes. New A3 assembly spaces. Minor structural infill of the existing staircase. This plan was reviewed in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additi0nal information before this plan check can be approved for permit issuance. COMMENTS v"T1.0 Building Code Information Energy Code: Update code edition to 2013. List of Drawings Revise Sheet #s for Cal Green Check List/Forms Add E0.0, E3.0, E5.2, E5.6, E6.1 & E7.0 Arrange list in order of sheet placement. Add the Following List of Defer~ed Submittals Provide the Following List of Deferred Submittals Fire Sprinkler System 2013 CFC 903 and 2013 NFPA 13. Fire Alarm System 2013 CFC 907 including CFC 907.2 sections specific to occupancy groups and 2013 NFPA 72 v"A1.1 Provide a North Directional Arrow v"D1.1 Provide a note: All demolition work shall be in accordance with CFC Chapter 33. Define *FTR LS1.1 V Life Safety Plan Provide a North Directional Arrow v" Clearly show compliance with CBC 1008.1.9.3 or 1008.1.1 0 for all doors, new & existing in the path of egress from all areas to an exit discharge. Note only, insufficient. Yage . .l or 4 ·· V~learly sh0w: exit signs and jDaths .of egre~s from Door 1'54S to two -separate exit discharge doors that l~ad to a public way. V'There are exit signs above doors leading to open exterior patios. The doors from the larger open. exterior patio egr$sses through· only one. pair of exit doors, that do not swing in the direction -of egress. Pl~ase justify. · · ti Provide this note: Obstructions in the path. of egress in the-open -exterior patio area will not be added. N9te is-not .fully legible. Please revise. · · Gl':Exit door from Break Room 154 through open exterior patio must be equipped with panic hardware, Panic hardware as denoted an She~t A2. 1' &/Show the path of egress from all improved areas to exit dischc1rge doors. Denote existing doors and h'ardware types on the Door Schedule shown on_A4.1. VDenote .all doors eqlJippe.d with electronic locksets and card readers and coordinate with A2.2, A4.1 &E3.0. A100,.100, 104A, 120,133, 118i 1-42, 1.44,-146, 146A, t47A, ·t48A, 156A, 156AB. Revised VDenot~ the occ1,Jpancy group,· square footage, occup~nt load-fc1ctor and occupant load for each occupied room/area based on the function of the room and workstation layout in open areas. CBC Table 1 004, 1. 1. · · ·· · ·· · , v Clarify functions of Fiex Room 119 and Satimo Room 130. VA2.1 V Provide a North Directional Arrow I J..eg~nd ti Provide keynotes for hexagon symbols. v'Pr:ovide references to wall details on Sh!3et A4.1. I Vindicate. wheth~r corridors are rated. Office Plan v'Denote all doors equipped with electronic:fockset~ and .card readers and coor9inate with LS-1, A2.2, A4.1 & E3·.o , V It Appears That The Card Reader Is-On The· Egr.ess. Side Of Ooor .118. Please Revise. Add a note: 1CR will not be installed on the egress side of exit doors. : a/Label the· door leading to the smaller open exterior-pc!ti9. · &/Label Door 146 a0d coordinate with the Door Schedule on A4.1. t/ Identify the Main Exit Door. CBC 1008.1 :9.3.2. ... -,,.· -~ . Yage .5 or "I --"? --.... Vindicate doors equipped with panic hardware from all assembly areas to an exterior exit discharge. CBC 1008.1.10 v'Show fire extinguisher symbols on plan at their required locations v'A2.2 v'Legend Provide references to wall details on Sheet A4.1. v' Enlarged Office Plan Denote all doors equipped with electronic locksets and card readers and coordinate with A2.1, A4.1 & E3.0 v'lt Appears That The Card Reader Is On The Egress Side of Doors A100 EX and 144 EX. Please Revise. Add a note: CR will not be installed on the egress side of exit doors. v'A3.1 Provide a reference to Sheet E2-1 for exit signs and means of egress illumination. A4.1 Hardware Note 3 Clearly show compliance with CBC 1008.1.9.3 and 1008.1.10 for all Existing doors in the path of egress to an exit discharge on LS-1. Door Schedule Add a note: All doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. v' Provide specifications for Hardware Type 11. v'Hardware Groups Indicate doors equipped with panic hardware in A3 occupancies. CBC 1008.1.1 O Indicate main exit door. CBC 1008.1.9.3.2 Coordinate electronic iockset locations with Sheet E3.0 Card Reader may not be installed on the egress side of exit doors 102 and 105. Please justify location of Card Reader for door access. CBC1008.1.9.8 v' Door Types Illustrate door hardware types. I.e. lever or panic hardware, etc. for Existing Doors. v'Electronic Lockset -Provide the following note: Card reader/Electric hardware will comply with CBC 1008.1.9.8 and will be field-tested. v' Address all criteria in CBC 1008.1 .4.4 Access-controlled egress doors. Page 'for 4 VA10.1 v' Add this Note: All finish materic;1ls· shall· comply with -CBG Chapter 8. A 10.0.0 t.i'Finish Sctleduie Provide manufacturer's specifications, listings or other acceptance criteria for flame spread and smoke developed index for new carpet, padding and carpet base. CFC 804. el-'M4.0 t/Deriote air-moving systems supplying ·air in excess of 2000 cfm equipped with California State Fire 1Marshal listed smoke .detectors. CMC 609. -V.Roof Plan, · Denote any new mechanical units·. on a roof plan. ' ' :t/E2.1 Oenote· mecins of egress illumination and air required exit signs oh plan that-match symbols shown on Sheet EO.O. For one example, denote exit signs in Break Room 1"94 & Training room '155. Coordinate ·e)(it sign locations with LS1 .1 & A3; f. Oenote directional exit signs, where req.uired, from all occupied areas to the exit discharge .for ~dditiona! required exit signs. CBC 1011. · .t/ Add the following notes: 'Means 6f egress illumination level shall be not less. than 1.,,foot ·candle at the walking surface CBC 1006.2. Provide 90-rninute battery. backup where requi_red. CBC 1006.3 · .f/'Exit signs shall be illuminated at all times and ·equipped with minimum 90:.minute battery backup. CBC 1011.5. . QI Photometric Plan Provide a photometric plan. Indicate means of egress illumination that illustrates-illumination levels of not less than 1 foot-candle at the walking surface ·throughout the Means of Egress system, which· ,consists of the Exit Access, Exit and Exit Discharge: The exit aGcess is that portion of the means of . egres·s system thc;1t consists of all floor areas-that lead .fr.om usable spaces within the building to the exit . or exits serving that floor area.· Exit access begins at the furthest points within each room or space. an·d . ends cit the entrance to the exit, that portion .of the ri'}eans .of egress system between the exit access : and the exit discharge or public way. CBC 1006.2 . . t/E3,9 Coordincite electronic lockset and card reader locations with· 'Sheet A4.1 · · Car9 Reader may not be installed on the egress side of exit doors 102 and 105. CBC1008.1.9.8 . .END OF COMMENT . l .Page 1 or:, CORRECTION LIST 3 BLDG. DEPT COPY Daryl K. Jame~ & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760} 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Richard Platt -Arco Murray PROJECT NAME: NETGEAR Checked by: Daryl Kit James Date: 8/21/2014 JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2200 Faraday Ste150 PROJECT DESCRIPTION: CB141263 Approx. 35,000m Renovations of existing 1 story office area including new non-rated partitions and finishes. New A3 assembly spaces. Minor structural infill of the existing staircase. Thi~ plan was reviewed in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, ~larification or additional information before this plan check can be approved for permit issuance. RESUBM11rTAL:JNST:R,l!lCTIONS'.T.O:AV:0fi:ro-et).¥JN'.EXPEDl:'[ED:RE:cHECK.SERVIGES • Corrections or modifications to the plans must ':be clouded and provided with numbered deltas and revision dates. • Provide a written response following eac_h comment, On This Correction List, explaining how and where each plan review comment has been addressed. • Provt~:~iJi_':_6_oi2y~qf_}3ciJia1iJii:):>_ep~i£!.oi~n((~~GHl,.90,QJtn,l~t§. Input fire revisions onto the Building Dept. plan check. • Please direct any questions regarding this review to: Daryl K. James 760-724-7001 or kitfire@sbcglobal.net • COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS DARYL K. JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 .P..L.EAS_I: pp ·N.or -~_1:Ql:l~~EJJl:YS_tGN~1:~Re; I9.11;9GJ:.PtO~fi.lVl;B-~QF" ~~VISE~· P~AN,S' COMMENTS VT1.0 · Building Code Information Energy Code: Update code edition to 20~. List of Drawings Revise Sheet #s for Cal Green Check List/Forms Add E0.0, E3.0, E5.2, E5.6, E6.1 & E7.0 I 1 Arrange .list in· order of sheet placemen_t. 1 Add the Following List of Deferred Submittals , Provide the Following List. of Deferred: Submittals Fire Sprinkler System 2013 CFC 903 and 2013 NFPA 13. t'age 1, Qt :,· Fire Alarm System 2013 CFC 907 including CFC 907.2 sections specific to occupancy groups and . 2013 NFPA 72 ·VA1.1 ; Provide a North Dire·ctional Arrow : VD1.1 Provide ~ note: All demolition work shall be in accordance with CFC Chapter 33. Define *FTR . i :Ls1.1 :v'Life Safety Plan ,Provide a North D1rectional Arrdw · .:cvlearly show ·qompliahce with Cl3C 1008.1.9.3 or 1008. 1'.-1 o for ,'all· doors, new & existing in the path 'of egress from all ~reas to an exit discharge .. Note only, insufficient. '#/ Clearly show exit sigcis and p~ths· of egress -fr0m Door "1'548 to two .separate exit discharge doors ·that.lead to a public way . . v'There are exit signs above doors leading to open exterior patios. The doors from the larger open . exterior patio egresses through only one pair of exit doors; that db not swing in the direction of egress, Ple~s.e jLJstify. · Provide this note: Obstructions in the path of egress in the op.en exterior patio area will not be added. v'Show the path of egress from all improved areas to exit discharge door$. Denote existing doors and . hardware types on the Door Schedule shown on A4.1. ·· · . Denote all doors equipped with electronic locksets ~nd card readers and coordihate with A2.2, A4.1 & : E3.0. AtOO, 100, 104A, 120, 133, 11·8; 14~, 144, 146,. 146A, 147A; 148A, 1'56A, 156AB. , VDenote the occupancy group, square footage, o.ccupant load factor and occupant load for each . ' .. occupied. ro.om/area based on the function .of the room and .workstation ·layout in open areas. CBC Table 1004.1.1. · v'Clarify.functions of Flex Room 119 and Satlmo Room 130. .A2.1 VProvide a North Directional _Arrow 1.-egend VProvide keynotes for hexagon symbols. v Provide references to wall detaiis on Sheet A4.1. ~"' I I ·1 ! .!:'age j or:, -.- Vindicate whether corridors are rated. Office Plan Cl'Denote all doors equipped with electronic locksets and card readers and coordinate with LS-1, A2.2, A4.1 & E3.0 v'Label the door leading to the smaller open exterior patio. Label Door 146 and coordinate with the Door Schedule on A4.1. -Vldentify the Main Exit Door. CBC 1008.1.9.3.2. Cl'lndicate doors equipped with panic hardware from all assembly areas to an exterior exit discharge. CBC 1008.1.10 v'Show fire extinguisher symbols on plan at their required locations v'A2.2 Vlegend Provide references to wall details on Sheet A4.1. v'Enlarged Office Plan Denote all doors equipped with electronic locksets and card readers and coordinate with A2.1, A4.1 & E3.0 VA3.1 Provide a reference to Sheet E2-1 for exit signs and means of egress illumination. Mi Hardware Note 3 Clearly show compliance with CBC 1008.1.9.3 and 1008.1.10 for all Existing doors in the path of egress to an exit discharge on LS-1. Door Schedule Add a note: All doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. V Provide specifications for Hardware Type 11. List door hardware type specifications for all Existing doors, in the path bf egress to an exit discharge on LS-1 in order to verify that hardware is readily openable from the egress side without the use of a key or special knowledge or effort, including Door 146 . . V Hardware Groups Indicate doors equipped with panic hardware in A3 occupancies. CBC 1008.1.10 Indicate main exit door. CBC 1008.1.9.3.2 Coordinate electronic lockset locations with Sheet E3.0 .l:'ag~ 4 or ·:, Card Reader may not be installed on the egress side of exit c:loors 102 and 105. Please justify location , of Card Reader for door access. CBC1008.1.9.8 · . ti/Door Types . Illustrate door hardwate types. I.e. lever or panic hardware., etc. tort;x.is.ting Doors. 1 v'Electronic Lockset"" Provide the foUowing. Jiote: Card reader/Electric hardware will comply with CBC · 1008.1.9.8 ~nd will be field-tested. · v' Address all criteria in CBC 1008.1 .4.4 Access-c.ontrolled egress doors. :v'A-10.1 ··- ' ,fl' Add thi~ Note: All finish materi·a1s shall comply with: CBC Chapt~r 8. -A 1.Q.0.0 . . ' . v'Finish Schedule : Provide manufacturer's $pecifications, listings or other acceptance criteria -for flame spread and smoke · developed index for new carpet, padding and Garpet base .. CFC 804 .. . M4.0 · el.Denote, air:.rhoving ,systems supplying air iti excess of .2000 cfm -e,quipped witl;i California State Fire ,1 Marshal:iisted smoke detectors. CMC 609, &/Roof Plan . Oenote any new mechanical units on a roof plan. E2.1 . :oenote means of e,gress illqn,i11ation and all .required exit signs on· plan that match symbols shown on I ., ,. •• • . · She.et E0.0. For on~ example, denote exit signs .in B'reak Room 154 & Training room 155. Coordinate exit sign locations with LS 1.1 & A3.1. : Denote directional exit signs, where required, from all occupied areas to the exit discharge for additional required exit signs. CBC 1011. v' Add the following notes: :, Means. of egress ,ilh.mJination 1.evel. shall _be not less than t.,foot Gandl.e at the walking surface. CBC , 1006;2. 'Provide 90,,rninute battery backµp where requited cac 1006.3 &/Exit signs· s.hall be illuminated at all times arid equipped with· minimum 90-minute battery backup-. CBC 1011.5. &/Photometric Pi~n ' Provide a photometric plan .. Indicate means of egress. illumination that illustrates illumination level$ of not less than 1 .foot-candle at the walking, syrface throughout the Means of Egress System, which consists of the Exit Access, Exit and E~it Discharge. The exit access :is that portion -of the means of egress system that consists of all floor areas that lead from qsable .spaces within. the building to t.he exit or exits serving that fli:>or area. Exit access 'begins at th<? furthest points within each room or·space and : ends at the entrance to the exit, that portion of the means of egress system between the exit access, . and: the exit discharge or public way. CBC 1006.2. · t'age :, or :, E3.0 Coordinate electronic lockset and card reader locations with Sheet A4. 1 Card Reader may not be installed on the egress side of exit doors 102 and 105. CBC1008.1.9.8 Not included. END OF COMMENT .l:'age 1 or 4 "!-. • • ..l CORRECTION LIST 2 BLDG. DEPT COPY Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T: (760} 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Richard Platt -Arco Murray PROJECT NAME: NETGEAR Checked by: Daryl Kit James Date: 8/6/2014 JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2200 Faraday Ste150 PROJECT DESCRIPTION: CB141263 Approx. 35,000[1] Renovations of existing 1 story office area including new non-rated partitions and finishes. New A3 assembly spaces. Minor structural infill of the existing staircase. This plan was reviewed in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. RESUBMIT:tAlJNSTRllCJIONS• .to ~AVOfD' DElAY'IN .. EXPEDITEDJRE'CHECKSER\ilCES: • Corrections or modifications to the plans mtist:b'e:;ij1t1ldcied and provided with numbered deltas and revision dates. • Provide a written response following each comment, On This Correction List, explaining how and where each plan review comment has been addressed. • '.l?:r_gvid~··::iJo~y~,.9-f: ;$,~il~ifiii:·R~P~.~i:n?tlL::cg~e:3fi}"_96ifi!1i~fu!{ Input fire revisions onto the Building Dept. plan check. • Please direct any questions regarding this review to: Daryl K. James 760-724-7001 or kitfire@sbcglobal.net • COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS DARYL K. JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 PLl:ASE··Oc::f:NOT'Ri:QtJIRE MY'SIGNA'.fURB.TO>ACCEPt':DEll\lERY. OF RE.VISE-D 1Pt.ANS '',', ,, =,--.' .. , ,,,,..,. l,, __ , ,,,-~i~,--,....,.,,, ',',',,,,,,,,,~,.._..-, __ ,,,,..,,-,,.-,~---,._-,,,,' ''' ,, COMMENTS VT1.0 Building Code Information Energy Code: Update code edition to 2013. List of Drawings Revis·e Sheet #s for Cal Green Check List/Forms Add E0.0, E3.0, E5.2, E5.6, E6.1 & E7.0 Arrang,e list'in order of 'Sheet placement. Add the Following 'List of Deferred SLibmitt~ls Provid,e the Foil owing List of Deferred Submittals Fire Sprinkler System 2013 CFC 903 and ~Ot3 NFPA 13. t'age·~ or 4 Fire Alarm ·system 2013 CFC 907 including CFC 907.2 sections specific to occupancy groups and 201·3 NFPA 72 . . el'A1.1 Prov,de a North Directional Arrow a/'D1.1 Provide a note: All demoliticm work shall be 'iil accordance with CFC Chapter 33. Defil")e *FTR LS1.1 Life Safety Plan el'Provide a North Directional Arrow· Cleprly show compliance with CBC 1008.t.9;3 or 1008.1..10 for all doors, new & existing in the path of egress from all areas to an exit discharge. · Cle~rly show exit signs and paths of egress from Poor 154B to two separate exit discharge doors that leactl to a public way. · ThJre ·are exit signs above doors. leading to open exterior patios. The doors from the larger open exterior _patio egresses throug'h only one pair of exit doors, that qo not swing ih the direction of egress. Please justify .. Sh.ow the path of egress from all improved areas to exit discharge doors. Oenote existing doors and h$rdware types on the Door Schedule shown on A4.1. VDenote all doors equipped with electronic locksets and carq. readers and coordinate with A2.2, A4.1 & E3.0. ·o/ Denote the occupancy group, square footage, occupant load factor and occupant load· for e~ch occupied room/area 'based on the function of the room and workstation _layout in open areas. CBC. Table 1004.1.1. · · · · · · V Clarify functions of Flex Room 119 ahd Satimo Room 130. A2·.1 , V Provide a North Directional Arrow ;Legend v'Provide keynotes for hexagon .symbols. , VProvide references. to wall defadls on· Sheet A4.1. ' el' indicate whether corridors are rated. ·, -·--.. . ~· .t'age ..i or 4 -••• lo, Office Plan VDenote all doors equipped with electronic locksets and card readers and coordinate with LS-1, A2.2, A4.1 & E3.0 Label all new and existing doors and coordinate with the Door Schedule on A4.1. label the door leading to the smaller open exterior patio. f/ Identify the Main Exit Door. CBC 1008.1.9.3.2. Vindicate doors equipped with panic hardware from all assembly areas to an exterior exit discharge. CBC 1008.1.10 V Show fire extinguisher symbols on plan at their required locations VA2.2 &/Legend Provide references to wall details on Sheet A4.1. &/Enlarged Office Plan Denote all doors equipped with electronic locksets and card readers and coordinate with A2.1, A4.1 & E3.0 f/A3.1 Provide a reference to Sheet E2-1 for exit signs and means of egress illumination. A4.1 Hardware Note 3 Clearly show compliance with CBC 1008.1.9.3 and 1008.1.10 for all Existing doors in the path of egress to an exit discharge on LS-1. Door Schedule Add a note: All doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Provide specifications for Hardware Type 11. List door hardware type specifications for all Existing doors, in the path of egress to an exit discharge on LS-1 in order to verify that hardware is readily openable from the egress side without the use of a key or special knowledge or effort. Hardware Groups Indicate doors equipped with panic hardware in A3 occupancies. CBC 1008.1.1 O Vindicate main exit door. CBC 1008.1.9.3.2 &/Coordinate electronic lockset locations with Sheet E3.0 Card Reader may not be installed on the egress side of exit doors 102 and 105. Please justify location of Card Reader for door access. CBC1008.1.9.8 Door Types _ Illustrate door hardware types. I.e. lever or panic hardware, etc. for Existing Doors. .l:'age 4·dt 4 e/'!Electr.onic Lockset -Provide the Jollqwing note: Card readerlElectric hardware will comply with CBC 1006.1.9.8 ~nd will pe field-tested. · · · · .v' Address all criteri'a in· CBC 1008.1 .4,4 Access-controlled egress doors·. vA10.1 v'Add this N.ote: All finish. materials shall, comply with. CBC Chapter 8. A10.0.Q v':Filiish Schedule Provide manufacturer's specifications, !is.tings or other acceptance criteria for flame· spread and smoke d~veloped index for new carpet, padding and· carpet base .. CFC 804. M4.0 tlbenote air-,movirig systems sl,lpplying air in excess of 2000 ·Cfm equipped with California Stat~ Fire M~rshal listed smoke detectors. CMC 609. v'Roof Plan ~enot~ any new mechanic;al units on a roof.plan. E2.1 Denote means of egress illumination and all r.eguired exit signs on plan th.at match symbols shown on qheet EO'.0. For one example, denote exit signs: in· Break Room 154. ¢oordinate exit sigh locations with L$1.1 & A3.1. Oenote directional exit signs, where .required, from all occupied areas to the exit discharge for additional required exit. signs. CBC 1011 .. v' Add the following notes: Means of ~gr~ss illumination ·1evel shall be not less. than. 1-foot candle at the walking surface CBC 1006.2. Provide 90..-minute battery back1:1p where req1;1ired CBC 1006.3 · v'Exit signs shall be illuminated at all times and 'equipped With minimum 90~minute battery backup. CBC 1011.5. . . Photometric Plan Provide a photometric plan. Indicate means of egress. :illumination that illustrates illumination levels of 11ot less than 1· foot-candle at' the walking surface throughout the Means of Egress System, which- consists of the Exit Access, Exit and Exit DiscMarge. The exit access is that portion of the means of egress system that consists of all floor areas that lead fr.om usable spaces within the building to the exit br exits ·serving that floor area. Exit access begins at the furthest points within each room or space and ends at the entrance to the exit, that portion of the m$ans of egress system between the exit access ~md,theexit discharge.or public way. CBC 1006.2'; · ea~o '.Coordinate electronic lockset and card reader locations with Sheet A4.1 · Card Reader may not be installed on the egress siqe of' exit doors 102 and 105. GBC1008.1.9.8 'l;ND OF COMMENTS ... -... -. _, .. _, ! --";3 Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 CORRECTION LIST T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Richard Platt -Arco Murray PROJECT NAME: NETGEAR l'age 1 or "I: BLDG. DEPT COP~l Checked by: Daryl Kit James Date: 6/12/2014 JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2200 Faraday Ste150 PROJECT DESCRIPTION: CB141263 Approx. 35,000[1] Renovations of existing 1 story office area including new non-rated partitions and finishes. New A3 assembly spaces. Minor structural infill of the existing staircase. This plan was reviewed in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. RES'tiBMltt1d:::1NSTRUCTICiNS: 'to·:AVOiB.DELAY1N'lEXREDIIED'.!RECHEdi:settVl'GES • Corrections or modifications to the plans rhUSt'1be·e1t::>ucled and provided with numbered deltas and revision dates. • Provide a written response following each comment, On This Correction List, explaining how and where each plan review comment has been addressed. • ptqik,~: '.t:i' .. :¢6py ~of .~·qtlding,' D.~.w~rt111~6t'.(Es~i[f .co111iti~nt~. Input fire revisions onto the Building Dept. plan check. • Please direct any questions regarding this review to: Daryl K. James 760-724-7001 or kitfire@sbcglobal.net • COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS DARYL K. JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 PLEASE't>:tfNbf REQWlRE";MY siGNATt'.i"Rt:.to ACGEP-T--OE1j\teRVoF: REvisei:f t>t.At~is ~ '" ' , ' ,, l ' > • • , > > • • • , , ' • • • • > , • • • • > • > > • V • • • • , ' > q • V '"' • , ' • ~ ' • , COMMENTS T1.0 Building Code Information Energy Code: Update code edition to 20~. List of Drawings Revise Sheet #s for Cal Green Check List/Forms Add E0.0, E3.0, E5.2, E5.6, E6.1 & E7.0 Arrange list in order of sheet placement. Add the Follo~ing Li~t of Deferred Submittal$· Prqvide the Following List' of Deferred Submittals Fir.a Sprinkler System 2013 CFC 903 and 2013 NFPA 13. Page" or 4. Fire Al~rm System. 2013 CFC 9.07 including CFC 907.2 sections specific to occupancy groups and 20'13 NPPA 72 . A1.1. P~ovide a North Directiona.1 Arrow 01".1 · Provide a note: All d~molition work shall be in accordahc~ with CFC ·Chapter 33. D~firie *FTR . LS1.1 Lif~ Safety Plan Provide a North Directional Arrow I . Cl~arly show compliance with CBC 1008.1.9.3 or 1 ooe.1, 1'0 for all doors in the path of egress from all areas to an exit di$charge .. Path of Egress from improved areas terminate at existing exit discharge doors. Denote existing doors oh the Door Sehedule shown o.n A4.1. · :Dendte .all doors equipped with electron·ic locksets and card readers and coordinate with A2.2, A4.1 & .E3.0. ·.Denote the occupancy grol!p, square foot~ge, occupant load factor and occupant load fc;>r each occupied room/area based on the function. of the room and workstatioh l~yout in open areas. CBC .Table 1004.1.1. · · · ·· · · · Clarify functions o.f Flex Room 119 and Satimo Room 130. A2·.1 Previde a North Directional Arrow ~rovide keynotes fo'r ht:}xagon symbol$. i .... ' j ,Legend Provide references to wall details on Sheet A4.1. Indicate whether corridors are rate,d. Denote all· do.ors equipped with electronic locksets and card readers and coordinate with LS-1, A2.2, · A4.1 & E3J'.> . : 1-abel all new and existing doors. and coordinate with Poor Schedule on A4.1. '. Identify the Main Exit Door. CBC 1008:1.9.3:2. 1· Indicate doors equipped with .panic hardware from all i;1ss~mbly areas to an exterior exit discharge . . CBC 1008.1.10 · Sh.ow .fire extinguisher symbols on plan at their required lotations ·, ! .1 A2.2 Legend Provide references to wall details on Sheet A4.1. Enlarged Office Plan .t'age .-s or 4 Denote all doors equipped with electronic locksets and card readers and coordinate with A2.1, A4.1 & E3.0 A3.1 Provide a reference to Sheet E2 for exit signs and means of egress illumination. A4.1 Hardware Note 3 Clearly show compliance with CBC 1008.1.9.3 and 1008.1.10 for all doors in the path of egress to an exit discharge on LS-1. Door Schedule Add a note: All doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. List door hardware type specifications in order to verify that hardware is readily openable from the egress side without the use of a key or special knowledge or effort. Hardware Groups Indicate doors equipped with panic hardware in A3 occupancies. CBC 1008.1.10 Indicate main exit door. CBC 1008.1.9.3.2 Coordinate electronic lockset locations with Sheet E3.0 Door Types Illustrate door hardware types. i.e. lever or panic hardware, etc. Electronic Lockset -Provide the following note: Card reader/Electric hardware will comply with CBC 1008.1.9.8 and will be field-tested. Address all criteria in CBC 1008.1 .4.4 Access-controlled egress doors. A10.1 Add this Note: All finish materials shall comply with CBC Chapter 8. Finish Schedule Provide manufacturer's specifications, listings or other acceptance criteria for flame spread and smoke developed index for new carpet, padding and carpet base. CFC 804. E2.1 Denote means of egress illumination and exit signs on plan that match symbols shown on Sheet E0.0. Coordinate exit sign locations with LS1 .1 & A3.1. Denote directional exit signs, where required, from all occupied areas to the exit discharge. CBC 1011. Add the following notes: Page~ ot 4 Meeins· .of egress illumination ·level shall be, not less than 1 ~foot candle at the walking surface CBC 1'006 .. 2. Provide 90-minute battery bacl<up where required CBC 1006.3 Exit signs shall. be illuminated at all :times and: equipped with minimum 90-minute battery backup. CBC 1011.5. . Photometric Plan Provide a photometric plan. Indicate means of egress illumination that illustrates illumination levels of not -less than 1 foot-candle at the walking surface throughout the Means of Egress System, which consists of the Exit Access, .!=xit and Exit Discharge .. The exit access is that portion of the me.~n·s of egress system that consists of all flo_or areas that lead ftom usable spaces within the building to the ex.it or exits.serving that floor area. Exit access begins at the furthest points within each room or space and ends at the entrance to the exit, that portion of the means of egress system between the exit access and the exit discharge or pul:)lic way. CBC 1006.2. E3.0 Coordinate electronic lockset and card read.er locations with SheetA4.1 M4:0 . Denote air-moving systems supplying ·air in excess of 2000 cfm -equippe.d with California State. ·Fire · Marshal listed smoke detectors. CMc· 608. Ropf Plan Den·ote· any new mechanical units on a roof plan. Imprint Carlsbad Policy eo-6 on to roof ,plan. ' Provide a note ,that Intent B .(Fireman. S~fety) will be. maintained on previously approved roofs br ' provided on .roofs ·Of new byildings. Indicate provisions taken to Gbmply with Carlsbad Policy 80-6 Intent B. (Fireman Safety) where multiple · roof 1;1nits are ac!ded. : City of Carlsbad· Policies and. Procedures document number 80-6: Roof ,Mounted equipment is intended ; to prevent the installation of hazardous items such as propane tanks, wind driven generation equipment, , and any 0th.er hazardous or potentially heizardous equipment. This ·includes utility piping and conduit ' 1.4.,irrches or .higher above roof surface. E;lectricar or other utility wiring or cabling not securely placed. in : condl!it, raceways or properly affixed to ·tl;le structure, or that which-may be a trip or strangulation hazard. Additionally, it was· intendeq to address building openings and roof coverings or features that posed a fall hazard to those unfamiliar or subject to impaired senses as might be encountered during . smoky and fire conditions or at night I ( While this Policy does not provide. specifics, it deres ,provide the. City ,the opportunity to review and comment on anything that ·is re.of mounted or pmvides ah opening such as vent risers, skylights, light- , wells, etc. END OF COMMENTS HSA HSA & ASSOCIATES, INC. CONSUL TING STRUCTURAL ENGINEERS 16700 VALLEYVIEW AVENUE, SUITE220 LA MIRADA, CA 90638 TEL: 714.522.0030 FAX: 714.522.0040 STRUCTURAL CALCULATIONS FOR NETGEAR TENANT IMPROVEMENT 2200 FARADAY A VENUE, CALRSBAD, CA 92008 SEP 1 I 2014 HSA & ASSOC IA TES, INC. JOB NO: 14-099 DATE: MAY-14' ENGINEERS: MGC BSA & ASSOCIATES, INC. JOB# //(-0~9 DATE ,v/4-1-ff.tl DESIGN d&-l. CONSULTING STRUCTURAL ENGINEERS 16700 VALLEY VIEW AVENUE • SUITE 220 • LA MIRADA, CA 90638 PHONE: 714.522.0030 SHEET # ( f-i ;_' -"-61----:1--..;.6_.1 _ ___,,,._.--~6-1 --1 - ,I (E.) W r1,1. I? x/4 I il"' (£) lo,i(... r1ef---a.l Ocdt. ' {F.)wlz.;r..l? ' , --------- (I::} {~11(., " r1ef-o-l ;Jee, l_-----;'lz."./8 6-/l. J"'leful /Jed:. vv/ Z 'lz_" (.,11e,rei-e t~ve r {tvtuA-c.he5 1.,v/ ex,-.;./i',13) (i·, h ~ w{!-iJh./-) locx.:>/r,13 Crikr,o. ;:;::.') J)e,,,d k>,tds: t't,,1crek ,0e1-<,-l fJc~k. ~ -z.g f'-"f {erlt/1-") ~ 4 /'> f f;r,/1Uer5 ;-/5 ~~f tvleduv,.·t,,,-{ ~ Efet/1,· i.:..{ == 2. 17">{ 11-JJ '{ ~/1t--rcf-e tl.,e 1v 1Je.rledrvr1 Ef 1'1,":>c. ~ 4,5 /75f ·1..;:,f-c,. I /Je.,.J l,Md ~ tr£J ,,,y l-rv e lv,.__J , foe> 11~! (,,,,,,,,11'(!'::f,.,rc,ile) I fl Q (.x-l-c.1.lvj -:=') / 1z IO G4 ;,in,:/e >(7.:>:/1 }?1eh-l dbl< <-vtf/,1 21/z II L.rJh/t,v(?/Shf {..c,,<1Cr'e/--e. t.>Ver Hi .. I-ffh./1s t '-,:/' ;;> J 4 4 ~f-f-~, I /.:;,_..,,A:,/ e i ..,,-ad t;.;,.f'v-c.r-f-y. 5£e r1e,d-fa.~e. f°'.Jr 5c.,.,,,,.1ed C...fy <->f rr?5/el frve verc..; c0 J.,_ (1J'3 l<i)'';Je f~,r 1..--11/:: {.:t.1lacrly. -PLB '"'or B R=UKMLUi'\ .... • a .4 in. TOTAL SLAB DEPTH .. 1\11 Light Weight Concrete (145 pcf) • 27.8 psf 7 Welds .. 5 Galvanized or Phosphatized/Painted j ·,', !;"1(!3 ____ / 1 Hour Fire Rating ------,. • Deck Weight and Section Properties ~ Weight (psf) Id for Deflection Moment Allowable Reactions per ft of Width (lb) -----. -· --• ------. ---Single Multiple --Gage Galv Phos/ +Sen -Sen End Bearing Interior Bearing Span Spans ----------.. G60 Painted (in.4/ft) (in.4/ft) (in. 31ft) (in.3/ft) 2" 3" 4" 3" 4" 22 1.9 1.8 0.177 0.192 0.176 0.188 935 1076 1163 1559 1671 I~ >'-.. :; ... ,.' 20 2.3 2.2 0.219 0.231 0.230 0.237 1301 1492 1609 2190 2340 <l =~ ,::..1 .. 18 2.9 2.8 0.302 0.306 0.314 0.331 2181 2484 2667 3714 3950 'IJJ k· . .. 16 3.5 3.4 0.381 0.381 0.399 0.410 3265 3699 3955 5607 5938 i~-~ .. Allowable Superimposed Loads (psf) ···$··., :-11111;:1 . , ... .,. ... ~ ',..(-,'.,•I .. Max. Span (ft-in.) ./:·:·.-:1 Gage Spans UCS1 --------------~----'f.l;f;·.) di 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" It". ·• ,..., "'~ '°'I 1 6'-9" 303 265 206 181 160 142 126 113 101 91 82 22 2 7'-11" 303 265 234 209 160 142 126 113 101 91 82 di 3 8'-0" 303 265 234 209 188 142 126 113 101 91 82 di 8'-1" 318 279 246 220 197 150 134 120 108 97 88 r:SI 20 2 9'-5" 318 279 246 220 197 178 162 120 108 97 88 3 9'-7" 318 279 246 220 197 178 162 148 108 97 88 di 1 9'-2" 301 266 237 213 192 175 131 118 106 96 ... ~ 18 2 11 '-1" 344 301 266 237 213 192 175 160 147 135 125 di 3 11 '-4" 344 301 266 237 213 192 175 160 147 135 125 1 9'-10" 342 300 265 236 212 192 174 159 117 105 95 111111 16 2 12'-3" 342 300 265 236 212 192 174 159 146 135 125 ... 3 11 '-11" 342 300 265 236 212 192 174 159 146 135 125 --1 Max. UCS = Maximum Unshared Clear Span (ft-in.) Shoring required in shaded areas ta right of heavy line. --Allowable Diaphragm Shear Values, q (plf) and Flexibility Factors, F (in.lib x 106) .. Gage Welds --------Span (ft-in.) --------------------------------- di 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11 '-0" q4 1659 1621 1588 1559 1534 1512 1493 1475 1460 1445 1433 --F4 0.50 0.51 0.52 0.53 0.54 0.55 0.55 0.56 0.56 0.57 0.58 ... 22 q7 1869 1814 1767 1727 1692 1660 1633 1608 1585 1565 1547 ..... F7 0.44 0.45 0.47 0.48 0.49 0.50 0.50 0.51 0.52 0.53 0.53 q4 1726 1680 1641 1607 1577 1551 1527 1506 1487 1470 1455 ~ F4 0.44 0.45 0.46 0.47 0.48 0.49 0.49 0.50 0.51 0.51 0.52 --20 q7 1978 1913 1857 1808 1766 1728 1695 1665 1638 1614 1592 --F7 0.38 0.39 0.41 0.42 0.43 0.44 0.44 0.45 0.46 0.47 0.47 ... q4 1880 1818 1766 1720 1681 1645 1614 1586 1561 1538 1518 F4 0.35 0.36 0.37 0.38 0.39 0.40 0.40 0.41 0.42 0.42 0.43 ... 18 q7 2215 2128 2053 1988 1932 1882 1838 1798 1762 1730 1700 A F7 0.29 0.31 0.32 0.33 0.34 0.35 0.35 0.36 0.37 0.38 0.38 *" q4 2048 1972 1906 1849 1799 1755 1716 1681 1650 1621 1596 ~ 16 F4 0.28 0.30 0.31 0.32 0.32 0.33 0.34 0.35 0.35 0.36 0.37 -" q7 2468 2359 2265 2185 2114 2051 1996 1946 1901 1861 1824 ... F7 0.24 0.25 0.26 0.27 0.28 0.28 0.29 0.30 0.31 0.31 0.32 --~ www.vercodeck.com VERCO DECKING. INC. VF4 El 43 ..,...... BSA & ASSOCIATES, INC. CONSULTING STRUCTURAL ENGINEERS 16700 VALLEY VIEW AVENUE • SUITE 220 • LA MIRADA, CA 90638 PHONE: 714.522.0030 fTl!/-L {)f:x(L SH/'{'u/l... {)£-!>rfrtJ t' (l ,, p L >" ~,< 114 c .. r1 ~, ::;.> JOB# /y-o'J) DATE ,vr/1-':f-f tr' DESIGN ,-1t~"- SHEET# _ __._ __ _ J_ .,..,,.-:::;,:. (}L:;;. 40 ('>{ .>< C1 ::-/20 tlf ,__ li-~ {O,? ff.{ ;<y_ I .:: >oi> rlf 2- 41 ~ee i/le,<f-t:J...'jV> ~ r e;1e1 c.,l,l.lc fleSvr f> k. we(J,-11-s L--lf~'C r ~1 :;::;. .f!:::J-;:; 2-,-·Z11 ;( ]_ 7-.J_ ~ I), 6 ;{ 7,.J ks½ ~ ( /. I .fl-/(-, ~ f/,e"'-r le-,,,,vrJ ,M t,..,/e(./t:1"3 ::: (!Zl? l'lf rs 0,.::, 1Ar) ~ }L ..:.: j 4 c/ ;:::-r.J, tl/-- "2. Title Block Line 1 You c13n changes this area using the 'Settings' menu item and then usingthe "Printing & Title Block' selection. Tllifl Block Line 6 Project Title: Engineer: Project Descr: Project ID: Printed: 13 MAY 2014, 1:42PM Steel Beam . File: c:\UsersiinehmenDocuments\ENERCALC Data Files\asdasdfasd2312312312.ec6 ENERCALC, INC. 1983-2012, Build:6.12.10.31, Ver.6.12.9.30 Description: Metal Deck Suppurt Angle Load Combination Set: ASCE 7-10 Material Properties Analysis Method : Allowable Strength Design Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Bending Axis : Major Axis Bending Load Combination ASCE 7-10 D(0.12) L(0.3) T T " Span= 4.0 ft L3X3X1/4 Fy : Steel Yield : E: Modulus: T ; " 36.0 ksi 29,000.0 ksi ,, -·L ____________ j _A~p~p_li_e_d_L_o_ad_s ______________________ s_e_rv_ice loads entered. Load Factors will be applied for calculations. Beam self weii:iht calculated and added to loads Uniform Load: D = 0.120, L = 0.30 k/ft, Tributary Width= 1.0 ft, (Gravity Loads (w)) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Ma: Applied Mn I Omega : Allowable Load Combination Location of maximum on span ; Span # where maximum occurs 0.555: 1 Maximum Shear Stress Ratio = L3X3X1/4 Section used for this span 0.850 k-ft Va: Applied 1.532 k-ft Vn/Omega : Allowable +D+l +H Load Combination 2.000ft Location of maximum on span Span # 1 Span # where maximum occurs I Maximum Deflection l Max Downward L+Lr+S Deflection 0.049 in Ratio= 982 Max Upward L+Lr+S Deflection 0.000 in Ratio= 0 <480 Max Downward Total Deflection 0.069 in Ratio = 694 __ M_a_x_U_p_w_a_rd_T_o_t_al_D __ e_fle_c_ti_on ________ O_.O_0_O_in_R_at_io_= __ --~<360 _______ _ Overall Maximum Deflections • Unfactored Loads Load Combination Span Max.•.• Deft Location in Span _D_+l ___________ 1 ___ 0.06._92 ____ 2.-02_0_ Load Combination Max."+' Deft ----0.0000 Vertical Reactions . Unfactored Support notation : Far left is #1 Values in KIPS 0.088: 1 L3X3X1/4 0.8498 k 9.701 k +D+l+H 4.000 ft Span# 1 Location in Span o.oao·- -------------------------------------------Load Combination Overaii MAXimum D Only LOnly D+l Support 1 Support 2 o.85o--~o.aso- o.250 0.250 0.600 0.600 0.850 0.850 Title Block Line 1 You can changes this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Steel Section Properties Depth = Leg Width Thickness Area Weight Kdesign Ycg Yp Eo 0,87 0,65 = = = i 0,43 / ii E 0 :i;: 0.22 ./ I/ BEAM-->:=o 0.38 0,9 L3X3X1/4 3.000 in 3.000 in 0.250 in 1.440 in•2 4.900 plf 0.625 in 0.836 in 0.239 in 0.239 in ,,/"' ,,..----- 0,78 ------------0,4 I xx Sxx Rxx zx I yy Syy R yy Qs lz Sz Rz Tatu -------- 1.18 1$8 - = = = = = = = = = = Project Title: Engineer: Project Descr: Project ID: Printed: 1 J MAY 2014, 1 :42PM -File: c:\Userslmehmel\Documents\ENERCALC Data Fileslasdasdfasd231231231iec6 · 1.23 in•4 0.57 in•3 0.926 in 1.020 in•3 1.230 in•4 0.569 in•3 0.926 in 1.000 0.491 in•4 0.231 in•3 0.585 in 1.00 deg 1.98 Distance (ft) a -tO+L+H - 2.38 ENERCALC, INC. 1983-2012, Build:6.12.10.31, Ver:6.12.9.30 ----··------------J = 0.031 in•4 Cw = 0.02 in•6 Ro = 1.650 in r---_ I--... ~ " .__~ '--~ 2.78 3.18 3.58 3.98 -------"----- -0.4 -0.9 0.38 0.78 1.18 1.58 -0.018 g -0.03S ~ 0 -0,053 -0,071 0.34 0.70 1.0& 1.42 1.98 Distance (ft) • +O+l+H l,78 Distance (ft) ---- 2.38 2,14 II oo .. ,y. LO"l'j'. t>+L ~ - 2.78 2.50 2.86 --------------3,18 3.58 3.98 3.22 3.58 3,94 ' > JiiIS.A & ASSOCIATES~ INC. CONSULTING STRUCTURAL ENGINEERS 16700 VALLEY VIEW AVENUE • SUITE 220 • LA MIRADA, CA 90638 PHONE: 714.522.0030 JOB# DATE DESIGN SHEET# (l,-o?-1 f.A.,..1-\¼' c:1&-l 6'. fro,,.., fr<>\riJ.ed 0t'"t1t,vi1t5,?" ((o,,r frot.,,,,,r.-'1_5 ;'V'/C;n6ers •ve,e ,11,-fr~I[; Jes/f;r1ed wi(no,"f-ft,i(; 5fr.,.ir t?ferttYI 5 • o.. -fe11a.,;i f 1',-,-,(JO 1/r!rlt"/lf I ./'1c,erore of { lhe f/,;o,,- C::."',"r:tble vf hol/r'/1> eJ<!-r,q loo-J J ..... e + . .:, ,.////eh>( ofe.tf.: fr ti. >e& 11e,d f"'-512-for fhe of.,( T.1 -r..,6 fov 5-/t,.,·, c:>~e',11.,,,r;, IJ1.,_f ,~1d,c..,,../...e5 c,.\\ tne-f(t>(}," -yo,z,,h, c..'\.rtd <;i',dt:(5 ,._,,,-e,,·e (qrf71'r7_5 (Iv<>/-{o,>-..;,ls '-vdhP<--rfl-/2e .., fer1,·115 ,-11 /-'he. f>'? f. II II 11 LI 4 I >I ,.,. (E) TS8xSx½ COL TYF. L (EJ W3~xl24 ( -9') r------------( / ,----------71 :1~ 10 1 1 ii 62.0 62 0 I I TYF. • . 11 4 Fl.CS. 11 II ( II I II , II II II I ~ : J w I d ~ I ~ ([ I -' z I ..i, -I "' tJ I -.. ~ I ~ ~ : "<I' II II LI (EJ Fl.00~ DECK, 2v1' CCNC. OYER 1'12. X laGA MT!.. DK. // // // // // // // // IN12xl9 I 12 2.0 /...,.,,._ __ _ // ___ _ // // / /) // / /~ ..... ~ 1, X r :r ...... ~ I I I I I I I I ,.1 I I I I I ! I I I I I I I I I I I I I I I I I I I I .1 I I . I I I I I I I I I ----. I ----,..,_ . ~ I ~ I -->, I ·, I "-1 1 ...... 1" ~ -, ~ ~ ...... ~ (( ii 1--_.;. ___________ .m-------~l+l---------------f:±ll~IL I : (EJ 3!:>' O',~ mi.165 ( -5') : : 11 ii 11 ii ~ L -::... -::... -::...-::... -::... --::... -::...-::... -::...-::... -::... -::... _-::...-::...-::...-::... -::...--_s ----- PARTIAL 2ND FLOOR FRAMING FLAN l/4' • l'-0' (E) ~ (E)N2 <EJl-12 ,.r.,... -er 1.NDU$T~JAL WAST-i:WAiER OJS<ll-fAA(;E PERMJT . "L I I I. ·SCREENING· SURVJ:Y Date ~" (R _/~ . .. : 6\J~Jm3~1;1.,Natn!9' Ne;r.tJ-eAIL Streef:Address ::: dJ.;;;,{}O ~Ir'? if I stJ ·. - J=maif Ad,<Jress _____________ __,. _ _,....~_..,...;.,-----,-----;,,...,._...,....,,__ .PlEA$E:. CHECK ~!=Ill= IFYQUR'.BU.SINESS·lS. EXEMPT~ (O~:FtEV~Rl$~SJq~ CHEGlfr'ie,1?.0S BUSINESS) 'fvr Chee~ ~t ~~.li::>w,--tn.at-$re present at your facUltyz -~ --, ,--, ' " ., f\cld Cleaninr;J Jnk Manufacturing'_ Nuti:itlool;l( :sqppJ$:lmeo.t I P$settibly Laboratory· Vify,trntn M~nuJ~cNrlng Automoifva Repalr M~chtnlng tMll!,ing Painttn~.tElnlshfng .Battery Mani.rfacwrin.g Mahufatturihg .P~!nt M~nw.;~otofin,g S.tofuei · Manufaotorlng Membrane Mant.rfatturlng ·p~~9!'l~I Q;tre· Pr9~yr;t~· 8iptecli J.,.;;ji:>ora\ory (j,e. -Water filter-membranes) tv.fijOUfe;oJ;urlng ,Btllk PIJ~.mlcal storag_~-Metsr eastlrrgIFontfi'ng, ·~esttcid$. Manur~¢t~ring t Car Wash' · Metal Fal;>riP.a:tion · Packajlh -. ,., g · Cheimfo~I l\lf1;tnufijct1,1rln9, Metal Fli:Ushfn£) .P~rm~~.uff~I Man.1Jf?G\qrlt1g d~aft\tc~ P.urfficiation El~ctt:O~latltig tlntiluc:Ubg prep1,1rsors'.) Dry cJeanJng El.~ctrgies~ -p1$tihg 'P'ocqelain J;harnellfog ~i~_cb:I~ ·GQ.mpqo,~nf I Anodizing . P.bWer G.elierauoo MaliUfact.i:irii11;:f Coati~~ (f~e:. ,phosp.frafl.n})) :priotshop Fertilizer Manufaotqring-Re$,e~rqj,:ang De"t~JQptn~nf' Che.m191;1f E;1Q.tilng ./-N!!Illng, ·t=J!ro 1X,.ray. ·Processip~f Pl'inted c1rca1t aoard Rubl?,~iW Martufa~turinQ .. ManlJfaclurlo.g SemrconctuctorManufuot1.fring Food' Processlng· GI~ Manl.:lfa9furiog : M~taT Powqe~ FotmJng Sd~p.J Pet~.rg~ot M~nU.f~9b,.1,rt~g tni;IuetriafLauri<;try-, . Waste Tr$~fmentl'$forage . $1C.Cotfe,(s) (if:kiiown):.,._ _____ ____, _ __,.._...,....---,------.........,--- 'ij'r1efg¢s¢IPtto11.of bus.ihes~ activities .(PtQduc{lon/ Manufam,uring ·oper~ti9n$)~----- Estimated :Volume ctlndi.$trJat wast~w~tett¢ Q.(;)·dl~:Ch~.rg_ed.(g~ffd.ay)r ...... ______ _ List hazardblJ$·Wa~te~ $Je11~1:1;1te~ (type/ volume};----------------------- Date operati¢n begantorwill begin at thi~ location:------------------ Hava you applied for a Wastewater Dlschar9eq Permit from the .Enclna Wastewater-Authority? Yes No. lfyes, when: __ .,...... __ __,_....,.,...,,......,.------------"-.......... - .• ,. SAN ·DJ.EGO REGl,QNAL HAZARDOUS MATERIALS QUEStlONNAIRE OFFICE USE-ONLY UPFP# ..... ---------HV# ______ _ BPDATE. _ _.,1 _ __,1~·-- ,..8100 APN# PlanF!le# 'fb9,following questions ·nipresent the fac;llltY'.s-_actfvJttes,.NQT~he speclflc.ptoJe~ de.scrlptlon. P DE AR .. "EN .. -· . AZARDOUS MATE IALS b1v1s10· : · CCUP . NCV.CLASSIFICATION: Indicate by clrcllngJhe.item, wheth&:r your'buslness will 1,1se1 process, or st~ any ·ofU}e following hazardous mate as. I any ot ! E! . terns arE!: .rcled, app cant must contact ·the Fire. Protection Agenct Wlth jurlsdictron ptforto plan submittal, f\'acllity's Squ_11ra Footilge (lncludlng propose~·proJecl): ______ C>ccupaocy, Rating: __________ . 1. ~loslve or.l3la(!tihg,Agenls ~. ·Oma.1119 Pero~i:les 9. Water:Reaclives 13. Coitosives· 2. Compressed Gas8fl !3. O,Cldi?ers· 10. C!)'ogenfcs ~()lher Health 1-{azsrds 3, Flammable/CombusUble L{qyida 7-, Pyrophor!cs t1, Hlghfy Toxic or Toxic Materials <..2;:)None of 'l'heiie, 4, Fl(:lmmable Soficls 8. Unstable.Reactl11as 12, Radioactlves questions s YE!S, appllc;ant must,contact the·co0ntY--o San: . ego,Hazardous Materials-Divis on, 6/300 ·over an <;all (8li8j ~0~700 prior tQ the ls~uance pf a(!)uilding pe1JT1lt, · · · · fEl';SA!lE REQUIRED, Project>Gomplelfon:Daie, __ l __ t~ Expected Date-of occupancy: __J__j_ __ YES NO · · · · (for OE)VJ con~rucUon-or remocleflilg prpjects) - 1. D. 'ti[ ls your business iisteu on.the reverse side of-this form? (cileck all tnatapply). Q.CalARP ·Exemp,t Date Initials · 2. D T;iij; Will your l;iuslness dispose ofHazard,ous Substances or Medical W\ilste·in any ~mount? 3. ·o tl!J Will your bl)sln13ss store or ha11d1e· 1-iazardo~s Substances ln'ql!antlties equal to or greater than 55 gallons, soo.pouilds -200. cublc·ftiet, pr carcfnogens/reproducUve-toxlns In anY, quantity? ·o Ca!ARP Reqafred 4. D 5. q e. D 7. 0 ~ Willyour ~uslnessc1,.1se !:!0 existing_ orihstillJ:ar\ unµetgroond storage'tank? 00 Will your business-store or hanqle-RegulatE!d Substances (Ca!ARP)? oi;f Will yourbaslness,use or Install a-Hazardous W?ste Tank· System (Tltl!:l 22; Artlcl.e 10)1 ~ \/Viii your-. tiuslne1ts: store petrolElum. lh if.Inks or c;:ont,1Jnerl! ~f _your faclli\y with a-·total storage, capacity equal to· ~r greater than 1,~20 gallons? (Callforrifa's Aboveground Petrole4m stprage Act). · Date lnltlals 0 CalARP Complete I Oiijte Initials Ill:· SAN IEGO C U TY AIR POLLUTION. CONTROL DISTRltT: If th~ answ~r lo any of tne QU!lS~ons b¢low Is -ye!!, applicant must contact· the. Alr o ut on Contra, Is ct . , ·10124 Old Grove Ro'ad, ·san Diego, CA-92:1~1~-1.649; telephone (&58) 58~2600· prior to.the lli!!.W:ini;e,of a bµ!ldlng Qr deniolltlon permit'. Note: ff the· ans.war lo \:jUe!!_tJons ~ or ,5, Is yes, aj>pllcant must also sµbJTilt an ;a!!bestos notification form to the APCD at lea!!\ 1 o working days. prior tp commencing cjernolltlon onenovatlgn,, except demoljl!Qn·on'enovaHon of resltlelitlal·struc;tur.as,of ~Qur uril!s or lei,11. Contact.the:.b.PCD fp_r mpre. Information. YES N.b 1. D 12!1 wm:the s4bji;lct facility or constr1,Jctlon-acUvltles lnc;i4de operaUqns, or eq1,1lpment that E!mlt-or are capabl,e of emlt\ing an air contaminant? (See·the · APCD factsheet at http://www.sdapcd.org/lnfolfacts/permlts.pdf. ancl ttiei 11st of-fyplC(:11 equipment requiring an APCO permit on the reverse side 0 3.. 181 4. D D 5. Qfthls from; Contact APCD,Jfyou nave ahy-questrons). . . _ . D .{ANSWER O~LY IF QUESTION i IS YES) Will the subJect faclllly be.local!KI ~t)lln 1,000 f~\ of the-01,rter.boundary of a school (K througq 12)? (Search 'the.California School Directory at http://yMryy.cde:ca.gov/re/sd(for public and ptivate schools·orcontact tne appropoate school district). 0 Has a survey been pel'formed to determine the presence of Asbestos Co,n,t~hJ!ng Mater!~ls? . _ I&) Vvill.there ~~ ~ilQ~tion that lnvolvEls·hangllng of any fl:la,ble asb~stos materials, .or disturbing any mater!'al ·that contains non-friable asbestos? ~ Will there be demolition Involving the removal of a load supporting structural tneniber? Briefly describe proposed project: o I la-! c:l..ol 1 Date .FOR OFFICIAL USE ONLY: FlR!:;DEPARTMENTPCCi.fPANCYCLASS!FICATlON:, _______________ ___, ____________ ____ BY~-----------------------,.---DATE: _____ ..__ __ EXEMPT OR NO fURTHERINFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR 09cueANCY' RELEASED F.Oij OCCUPANCY COUNTY-HMO* Af!CD QOUNTY~f-lMO APCD COUNTY·fiMD AP.CD A.stamp In tl1Js·t)ox.on y exempts llustnesses from completing or upaatlng a Hazardous Materials Business Plan; Other-permitting requ_1rements ma .still apply. . y HM-.ml.(02/il) County ofS!l,n·Diego-DEH;.. Ha2ardous Materials Division ~ «-~~ ~ CITY OF PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Building@carlsbadca.gov ARLSBA B-18 Project Address: 2,,2-00 ~ Permit No.: Git:> l'-1 l~y> Information provided below refers to worR being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains ....................................................... 1 New building sewer line? ......................................................................................... Yes __ No .l{__ Number of new roof drains?............................................................................................................... V/ 4 Install/alter water line? ................................................................ : ........................................................ _l_ Number of new water heaters? ......................................................................................................... M_ Number of new, relocated or replaced gas outlets? .................................................................... NIA Number of new hose bibs? .................................................................................................................. k/~ Residential Permits: New/expanded service: Number of new amps: __ V,...,r/A .......... ___ _ Minor Remodel only: Yes__ No Commercial/Industrial: Tenant Improvement: Number of existing amps involved in this project: Number of new amps involved in this project: New Construction: Amps per Panel: Single Phase ............................................................... Number of new amperes ___ µ~~-~--- Three Phase ................................................................. Number of new amperes __ _.l...,./1; .... ;1 ___ _ Three Phase 480 ........................................................ Number of new amperes __ -=&/. ..... 1/ A-..... .._ __ _ Number of new furnaces, A/C, or heat pumps?............................................................................ 'Alf New or relocated duct worl:?? .......................................................................... Yes ?( No __ _ Number of new fireplaces? ................................................................................................................. _O_ Number of new exhaust fans? .......................................................................................................... .. 1 Relocate/install vent?............................................................................................................................ i_ Number of new exhaust hoods? ........................................................................................................ __{)__ Number of new boilers or compressors? ........................................................... Number of HP IJ B-18 Page 1 of 1 Rev. 03/09 ,., Raenette Abbey From: Mike Peterson Sent: Monday, June 23, 2014 7:33 AM To: Subject: Raenette Abbey; Janet Altar; Serena Schlosser; Laura Stuppy-Moore FW: 2200 Faraday Ave -STE 150 -NETGEAR PC #14-1263 FYI From: Will Foss Sent: Monday, June 23, 2014 7:25 AM To: Platt, Richard Cc: Vandeloecht, Louis; Niedhammer, Chris; Mike Peterson Subject: RE: 2200 Faraday Ave -STE 150 -NETGEAR PC #14-1263 All, Typically, the underground plumbing is the first phase of construction since most of the framing can't be done until the trenches are backfilled and poured. From the checklist you may have an issue with minimum facilities. Please have your plumbing contractor give me a call to discuss. Also please send me a copy of the contractors projected critical path and schedule. You may get started on the demolition and staging with a demo permit. Will From: Platt, Richard [mailto:rplatt@arcomurray.com] Sent: Friday, June 20, 2014 9:04 AM To: Will Foss Cc: Vandeloecht, Louis; Nied hammer, Chris Subject: 2200 Faraday Ave -STE 150 -NETGEAR PC #14-1263 HiWill, I am following up on the voicemail I left regarding 2220 Faraday Ave Ste #150 PC #14-1263. I have attached EsGils's plan review for your reference. As you will notice, EsGil is requiring plumbing plans and calculations for the proposed changes. The changes we will be making are replacing the existing bathroom fixtures with new (we will not be reducing or adding to the amount of existing fixtures), replacing break room sinks/faucets and adding new water drinking stations. Unfortunately, we do not have access to the necessary information readily available for us to prepare the requested drawings. Since time is of the essence, we are asking if the City of Carlsbad will allow us to defer the plumbing drawings as this may take several weeks for us to gather this information. If acceptable, we can provide a note on the first page of our architectural drawings. We appreciate your understanding and feel free to contact me on my cell phone at 630-520-4847 with any questions you may have. Thank you, We moved/ Our address and phone numbers have changed; click the vCard fink below to update your records. Richard Platt 1 Project Manager ARCO MURRAY I INTERIORS DIVISION 3110 Woodcreek Drive I Downers Grove, IL 60515 o: 331.251.2726 I d: 331.251.2714 I m: 630.s20.4847 vCard I www.arcomurrayinteriors.com 2 CB141263 2200 FARADAY AV 150 NFTGFAR-~!i nnn .<:I= Tl Tf'I .. ----,_ "'-~----·-----·-~~-- &}ro)1lf tD p<_Ps-µ I E:/\6-I F, I<-£, I 8=,G-/L c»/ .S~T ~'to QA6 (p/10/1'-f &/1(1Jf1lf E::::i'Suvi,L--~ 1)1/l'-f ~@_~ (2.cf\LC.S, fl I /l<j ~-7Idfl-L -~ J[ /4 &/IL ~I l{ I / q urr, :iµ:@ p-c) CJ\.)) ,,--oc:10:. ~ e-sc.i LL ___-;-I ~ vj I \( ( ( y ~ -C--(L JJ/-, '\L) tJ>s,(L-w ,t I' S'\'(LM.c:f CfttLS <Cf/1.f/t'-( >ttJG~D 6t1'1 s :SI st<lM-6 ~S ---wui::~n~ C?/211/,tj -LSSClW Final Inspection required by: 0 Plan O CM&I 0 Fire 0 SW OISSUED I ocv. Approved Date By BUILDING Cf/Z.Z/ (l/ Cm PLANNING <p /~ I 11.f (J.,{l._ ENGINEERING -1 I ·7__,,//'--i ~ FIRE Expedite? ( Y j N 9/23//c/ ~R_ DIGITAL FILES Reauired7 y N I HazMat APCD Health Forms/Fees Sent Rec'd Due? By Encina u/fd/ 1t..f y N Fire y N HazHealthAPCD (4/(,t)/IC../-' y N PE&M ~l~/lc../ y N School y N Sewer y N Stormwater y N - Special Inspection Kl LI /{Cf y N SW CFO: y N LandUse: Density: lmpArea: FY: Annex: Factor: PFF: y N Comments Date Date Date Date Building 1//tr.,,,/•l/ fs/ tr/,</ q 1711'---1 Planning Engineering Fire ~ { { z.,/ ,c.f, Ir/to[ H IS(f ZA II\./ if/'-{ /1<-1 Need? r &A.. P.1 (!, ~ne DDone DDone ODone