Loading...
HomeMy WebLinkAbout2206 RECODO CT; ; CB070192; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 05-14-2007 Residential Permit Permit No: CB070192 Building Inspection Request Line (760) 602-2725 Job Address: 2206 RECODO CT CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2164930800 Lot #: 0 Applied: 01/23/2007 Valuation: $56,509.00 Construction Type: VN Entered By: LSM Occupancy Group: Reference #: Plan Approved: 05/14/2007 # Dwelling Units: 0 Structure Type: Issued: 05/14/2007 Bedrooms: 0 Bathrooms: 0 Inspect Area: Project Title: HOLST RES- ADD 455 SF MST BD@ Orig PC#: 2ND STORY, 111 SF BACK PORCH Plan Check#: Applicant: . Owner: KIM CASTLE HOLST FAMILY TRUST 10-18-04 4715 60TH ST 2206 RECODO CT SAN DIEGO 92115 CARLSBAD CA 92009 Building Permit $381.01 Meter Size Add'I Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $247.66 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $5.65 PFF (3105540) . $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee . $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $69.00 Renewal Fee $0.00 ELECTRICAL TOTAL . $20.00 AddI Renewal Fee $0.00 MECHANICAL TOTAL $30.50 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee . $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $753.82 Total Fees: $753.82 Total Payments To Date: $753.82 Balance Due: $0.00 ( FINAL APPROVAL lnspectoL1 ' Date: lo 11 7 Clearance: NOTICE: Please take NOTICE that approval of your project includes the'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. 660,7 ' OL EST. VAL. Plan Ck. Deposit Validated By________________________ Date JJ.3jO7 Address (include B1d/Suite #) Business Name (at this address) Legal Descri ti D— —oe Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units ng Us j j Proposed Use SQ. FT. #of Stories # of Bedrooms # of Bathrooms aqa - - . I - - A,.. - - f'i•., IF ,, h Name Address - City State/Zip Telephone # (' ' (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is e 16 - xempt therefrom, and the basis for the alleged tc P jnot hf,hjndred d rscSOt cMUM — W-19t* MM V1 Im, WOR? UTO c Name - State License # Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier a d policy number are: - Insurance Company (9J1l1'pt1' FJ ( Policy No. _ 7 I'J674 JO Expiration Date /01 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure, workers' confensetion coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars cost of compensation, damages as provided for in Section 3706 of td/trst and attorney's fees. SIGNATURE DATE 11'16WNER BUILDER D I heieby affirm that I am exempt from the Contractor's License Law for the following reason: - I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). o I am exempt under Section Business and Professions Code for this 'reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number 1 contractors license .number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone number I contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address /.phone number / type of work): - PROPERTY OWNER SIGNATURE DATE E THIS SECTION FOR OSJöENfl ERMITSONLY,,Tr rr Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?• 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES; A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. _ 1.7 I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME LENDER'S ADDRESS_______________________________________________________ 19 APPLICAL TIFICAI!Od I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 140)days from the date of such permit or if the building or work authorized by such permit Is suspended or abandoned' at any time after the work is commen 8 f do f' 0 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE ' DATE WHITE: File YELLOW: Applicant PINK: Finance City City of Carlsbad. Bldg Inspection Request For: 10/16/2007 Permit# CB070192 Title: HOLST RES- ADD 455 SF MST BD@ Description: 2ND STORY, 111 SF BACK PORCH Type: RESDNTL Sub Type: RAD Job Address: 2206 RECODO CT Suite: Lot: 0 Location: APPLICANT KIM CASTLE Owner: HOLST SUSAN L Remarks: Total Time: Inspector Assignment: PD Phone: 6197298292 lnspecc I Requested By: DOUG Entered By: CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical VAct Comments 01 Comments/Notices/Holds Associated PCRs/CVs Original PC# CV010650 CLOSED ILLEGAL CONSTRUCTION ??; CV060269 CLOSED 0-BUSHES BLOCKING R.O.W.; lnsøection History Date Description Act Insp Comments 09/18/2007 89 Final Combo CO PD ON CARD 08/07/2007 17 Interior Lath/Drywall AP PD SHOWER 07/26/2007 17 Interior Lath/Drywall AP PD 07/26/2007 18 Exterior Lath/Drywall AP PD 07/20/2007 16 Insulation AP PD 07/20/2007 84 Rough Combo AP PD 07/19/2007 16 Insulation CO PD notice attached 07/19/2007 84 Rough Combo CO PD 07/16/2007 84 Rough Combo CO PD 07/10/2007 13 Shear Panels/HD's NR PD 07/10/2007 33 Service Change/Upgrade AP PD 06/25/2007 15 Roof/Reroof AP PD City of Carlsbad Bldg Inspection Request For: 07/19/2007 Permit# CB070192 Inspector Assignment: PD Title: HOLST RES- ADD 455 SF MST BD@ Description: 2ND STORY, 111 SF BACK PORCH Type: RESDNTL Sub Type: RAD Phone:;61998292 - Job Address: 2206 RECODO CT Suite: Lot: 0 Location: Inspecto ______ APPLICANT KIM CASTLE Owner: HOLST FAMILY TRUST 10-18-04 - Remarks: - Total Time: - Requested By: DON Entered By: CHRISTINE CD Description Act Comments 16 Insulation tZ Uor 1C4 14 Frame/SteellBoltinglWelding 24 Rough!Topout 34 Rough Electric 44 Rough/Ducts/Dampers Comments/Notices/Holds Associated PCRs/CVs Original PC# CVOI 0650 CLOSED ILLEGAL CONSTRUCTION??; CV060269 CLOSED 0- BUSHES BLOCKING R.O.W.; Inspection History Date Description Act Insp Comments 07/16/2007 84 Rough Combo CO PD 07/10/2007 13 Shear Panels/HD's NR PD 07/10/2007 33 Service Change/Upgrade AP PD 06/25/2007 15 Roof/Reroof AP PD 06/07/2007 11 Ftg/Foundation/Piers AP PD EsGil Corporation In tFartnership wit/i government for 3ui(Iing Safety DATE: May 10, 2007 JURISDICTION: City of Carlsbad PLAN CHECK NO.: CB070192 SET: II PROJECT ADDRESS: 2206 Recodo Ct. PROJECT NAME: Addition for the Hoist Residence O APPLICANT Uls PLAN REVIEWER U FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. L1 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. E The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IIJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IJ The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. LI Esgil Corporation staff did advise the: applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LI REMARKS: By: Steve Sanders Enclosures: Esgil Corporation 0 G El MB DEJ El PC 5/3/07 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 EsGII Corporation In cPartnersllip wit/i government for tBuirding Safety DATE: January 31, 2007 ci APP ICANT JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: CB070192 SET:I PROJECT ADDRESS: 2206 Recodo Ct. PROJECT NAME: Addition for the Hoist Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. Eli The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Terry Montello 4715 60th St. San Diego, CA 92115 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted Trry Montello Date contacted-.11 (byj) Mail Telephone Fax/ Person LI REMARKS: Telephone #: (619) 994-5557 Fax #: (619) 229-0642 By: Steve Sanders Enclosures: Esgil Corporation El GA El MB DEJ El PC 1/25/07 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad CB070192 January31, 2007 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES JURISDICTION: City of Carlsbad PLAN CHECK NO.: CB070192 PROJECT ADDRESS: 2206 Recodo Ct. FLOOR AREA: Addition 455 sq. ft Porch 111 sq. ft. REMARKS: STORIES: 2 HEIGHT: 24'-0" DATE PLANS RECEIVED BY JURISDICTION: 1/23/07 DATE INITIAL PLAN REVIEW COMPLETED: January 31, 2007 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/25/07 PLAN REVIEWER: Steve Sanders This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan .review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC. The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad CB070 192 January 31, 2007 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation. (California Business and Professions Code). Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. The City requires soils reports for 2d story additions. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). Section 106.3.4.1. City of Carlsbad CB070 192 January31, 2007 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Steve Sanders at Esgil Corporation. Thank you. City of Carlsbad CB070 192 January 3.1, 2007 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: CB070192 PREPARED BY: Steve Sanders DATE: January 31, 2007 BUILDING ADDRESS: 2206 Recodo -Ct. BUILDING OCCUPANCY: R-3 TYPE OF CONSTRUCTION: VN IBUILDING PORTION AREA (Sq. Ft.) Valuation / Multiplier Reg. Mod. VALUE ($) Addition 455 // 121.94 55,483 Porch 111 8.87 985 Air Conditioning Fire Sprinklers TOTAL VALUE 56,467 Jurisdiction Code 1cb IBY Ordinance Bldg. Permit Fee by Ordinance v Plan Check Fee by Ordinance 'UP'] I $372.011 I $241811 Type of Review: El Complete Review 0 Structural Only 0 Repetitive Fee 0 Other I Repeats El Hourly Hour * I Esgil Plan Review Fee Comments: I $208.33 Sheet I of I macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER Cl 070 09, DATE_9s/P c7i" (_(l' RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$109000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER DATE_______________ ENGINEER__ DATE_________________ 0OCsIM$fa,TT.PI,IIIIr9 Ennssi1ng ftiovU PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB - L.9 2 Address _ 2CjDcQ5!) Ce- Planner Erin Endres Phone(760)602- 4625 APN: t I ( c__' T12 Type of Project & Use: 'T)r OcC.X(X Net Project Density: DU/AC - Zonin' C— General Plan Facilities Management Zone: (7 CFD (ln/ Ut) _Date of participation: Remaining net dev acres:______ Circle One (For non-residential development: Type of land used created by this permit:________________________________________________ Legend: Item Complete 3em Incomplete - Needs your action Environmental Review Required: YES NO ____TYPE DATE OF COMPLETION: Compliance with conditions of approval?. If not, state conditions which require action. Conditions of Approval: 0 Discretionary Action Required: YES NO _TYPE APPROVAL/RESO. NO. DATE_____ PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:_____________________________________________________ )rJ 0 Coastal Zone Assessment/Compliance 7 Project site located in Coastal Zone? YES____ NO____ CA Coastal Commission Authority? YES____ NO____ If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES____ NO____ If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. 10 0 Incluslonary Housing Fee required: YES NO / (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES ___ NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) HMDMlNCOUNTERBldgPlnchkRevChktst Rev 9/01 Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North,arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 0 2. Provide legal description of property and assessor's parcel number. Policy 44— Neighborhood Architectural Design Guidelines 0 0 1. Applicability: YES NO—c -D 0 2. Project complies YES NO_______ Zoning: 0 1. Setbacks: Interior Side: Street Side: Rear Top of slope: Required c.2 D Showfl_ Required T ' Shown 9' Required Shown _ Required '4- Shown 9" Required ___Shown X-0 0 Accessory structure setbacks: Front : Required Shown Interior Side: Required Shown Street Side: Required Shown_____________ Rear Required Shown Structure separation: Required Shown 0 ,I ID Lot Coverage: Required Shown Height: Required 3O_'-'9C Shown Z4' 'D 0 Parking: Spaces Required .-Z7 Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown 0 0 0 Additional Comments______________________________________________________ OK TO ISSUE AND ENTERED APPROVAL INTO DATE H:DMINC0UNTERBIdgPInchkRevChkIst Rev 9/01 05/I11/2Ui( i:i b1 L( IUJ%ML ..UI'4I W rMar. 0&1 UJ 8039 1195 tide.ealifornia 0 (619) 443-0060 April 26, 2007 Brent Hoist 2206 Recodo Court Carlsbad, California 92009 SUBJECT: Pile No. 1147F2-07 Poundatlon I'lan Review Proposed Rsidentiá1 Building Site 2206 Recodo Court City of Carlsbad Dear Mr. Hoist: In accordance with your request, we have reviewed the foundation plan and specifications and find that the recommendations in our Site Inspection report dated April 1, 2007, are properly incorporated into the conatnlction docwnentL If you have any additional questions, please do not hesitate to qact our office. R.cspectfixUy submitted, 410h 4QJ/ R1S0 JCS/ss - cc: (3) submitted tjt!7#-1t-r NARAGHI ENGINEERING STRUCTURAL CONSULTANT - JOB SHEET NO: ______________OF. r-/ CALCULATED8Y: 4 Lakeside, 1101L TITEiMr 92040 (619)443-0060 P.O. Box 1195 April 1, 2007 Brent Hoist 2206 Recodo Court Carlsbad, California 92009 SUBJECT: File No.1 147F2-07 SITE INSPECTION Proposed Residential Addition 2206 Recodo Court City of Carlsbad Dear Mr. Hoist: SCOPE In accordance with your request, a Site Inspection has been performed at the subject site. The purpose of this investigation was to examine existing site conditions and provide engineering recommendations for the proposed addition to the existing single-family residence. It is our understanding that a second story is planned over the existing garage. FIELD INSPECTION In order to accomplish this purpose, a representative of this firm visited the site, reviewed the topography and site conditions and visually and textually classified the surface and near surface soils. Representative samples of the foundation soils were obtained from a test excavation three feet in depth and tested for density, shear strength and expansive characteristics. The existing footing where exposed was 18 inches in depth. SITE CONDITIONS • The subject site is a residential parcel located on the north side of Recodo Court. The property is relatively level in the area of the existing residence and in the back yard and then slopes down towards the street in front. The property is presently occupied by a two-story, single-family residence with attached garage and a swimming pool and deck in the back yard. Light cracking of driveway and tiatwork in front was observed. Adjacent properties are occupied by residential structures. Man made fill soils to approximately two feet in depth were encountered during the course of this inspection. The residence is relatively new and we would expect that the fill was placed during supervised grading and has been documented. -r Brent Hoist File No.! 147F2-07 April 1, 2007 SOIL CONDITIONS Soils in the test exploration were fill materials consisting of approximately 6 to 8 inches of topsoil underlain by medium dense, grey to tan, silty sands with clay binder to a depth of approximately two feet. The fill materials were underlain by native, medium dense to dense, grey with streaks of red, silty sand (sandstone) to the bottom of the excavation, approximately three feet in depth. Foundation soils were not considered to be detrimentally expansive with respect to change in volume with change in moisture content. CONCLUSIONS AND RECOMMENDATIONS If new footings are a part of the plans and documentation for the fill soils can be provided, conventional spread footings founded a minimum of 12 inches below lowest adjacent grade and having a width determined by the allowable soil bearing value as detailed above are recommended for foundation support for the new addition. Footing widths should be at least 12 inches for continuous footings and 24 inches for square footings due to practical considerations as well as Building Code requirements. This footing design is a minimum based upon the foundation soil type and does not take into consideration structural requirements. If no documentation is available, we recommend that footings for the proposed addition be extended through the fill a minimum of 12 inches into firm natural ground We anticipate that footing depths required will be 2 to 3 feet; however, this must be determined during footing excavation. Footing excavations should be inspected by a representative of this firm prior to placement of forms and reinforcing steel to insure that adequate depth has been achieved. Reinforcing in footings should consist of at least one #4 steel bar placed continuously in the top and bottom of continuous footings regardless of structural requirements. For footings deeper than 24 inches, an additional #4 steel bar should be added for each additional foot of footing depth. Reinforcing for isolated footings is dictated by the structural requirements. These recommendations are based upon on the soil type encountered and do not take into consideration the proposed bearing load. Concrete slabs-on-grade should be constructed to have a nominal thickness of 4" and underlain with a sand blanket of 3 inches in thickness. Provide minimum temperature reinforcement consisting of 6X6-10/10 welded wire mesh. The sand subbase (sand blanket) should have a sand equivalent exceeding 30 per ASTM D2419. All slabs should either have a conventional thickened edge or be poured monolithically with continuous footings at the slabs perimeter. Conventional thickened edges should be 8" thick at slab edge, uniformly tapering t Brent Hoist File No.1 147F2-07 April 1, 2007 to 4" thick at 2' from, slab edge. The thickened edges or monolithic footings should extend completely around the slab's perimeter. Construction arid expansion joints should be considered slab edges. Maximum spacing of expansion joints is 50' for interior slabs and 30'. for exterior slabs. A representative sample of the foundation soil was remolded to 90% of maximum dry density. Based on the following test results, a safe allowable bearing value of at least 2000 pounds per square foot may be used in designing the proposed second story addition. This value may be increased by one third for wind and/or seismic loading. Angle of internal friction 36° Cohesion 308 psf Unit weight 104.3 pcf Maximum Dry Density 115.9 pcf Optimum Moisture Content 13.1 Expansion Index 31 UNFORESEEN CONDmONS: Soil Testers assume no responsibility for conditions, which differ from those, described in the applicable current reports and documents for this property. Upon termination of the soil engineer's services for any reason, his fees up to the time of termination become due and payable. If it is necessary for the soil engineer to issue an unfavorable report concerning the work that he has been hired to test and inspect, the soil If we can be of any further assistance, please do not hesitate to contact our office. This opportunity to be of service is sincerely appreciated. Respectfully submitted, LosepbCyth,RCE21659 JCS/ss 3