Loading...
HomeMy WebLinkAbout2210 FARADAY AVE; 100; CB090997; Permit\ City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-12-2009 Commercial/Industrial Permit Permit No: CB090997 Building Inspection Request Line (760) 602-2725 Job Address: 2210 FARADAY AV CBAD St: 100 Permit Type: Tl Sub Type: INDUST 0 NEW Parcel No: 2121205500 Lot#: Status: Valuation: $12,000.00 Construction Type: Applied: Occupancy Group: Reference #: Entered By: Project Title: ABLATION FONTIERS-HIGH PILED STORAGE RACKS-COMBUSTIBLES Applicant: ATLAS EQUIPMENT CO. SUITE E 5360 EASTGATE MALL 92121 858-455-5800 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee $136.01 $0.00 $88.41 $0.00 $0.00 $2.52 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 Plan Approved: Issued: Inspect Area: Plan Check#: Owner: FARADAY POINTE-CA LLC Cl() JEANNE ALLEN PO BOX 4900 SCOTTSDALE AZ 85261 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Adqitional Fees HMP Fee TOTAL PERMIT FEES ISSUED 06/18/2009 RMA 08/12/2009 08/12/2009 Total Fees: $227.94 Total Payments To Date: $227.94 Balance Due: FINAL APPROVAL Date: -""qe;:..L,&..;-::..+---Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 ?? $227.94 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. I Ci_t,, of Carlsbad 115!'5 Faraday Ave., carlsbad, CA 92008 760-602-,2717 / 2718 / 2719 Fax: 760-602-8558 Building Permit Application #/Go CT/PROJECT It LOT# PHASE# It OF UNITS It BEDROOMS Date SUITE#/SPACE#/UNIT# AP-Zit.. -, to -'3'/ It BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE occ. b"la7!o~ m' l ll ... B 13 DESCRIPTION OF WORK: lnclu~cSqua,e Feet of Affected Atea(s} EXISTING USE PROPOSED-USE GARAGE (SF) CONTACT NAME (If Different Fom Applicant) ADDRESS STATE ZIP FAX EMAIL PROPERlY OWNER NAME ADDRESS CITY STATE ZIP PHONE FAX EMAIL ARCH/DESIGNER NAME &ADORES$ STATEUC.# CONTRACTOR BUS. NAME ADDRESS CITY STATE PHONE FAX EMAIL Cf.ASS CG, ZIP CITY BUS. UC.It IZ.6 ARE SPRINKLERS vesONoO (Sec. 7031.5 Business and Professions COdEi: AnyCi!:Y or County which requires a wrmit to construct, alter, improve, demolish orrepair any structure, prior to its issuance, also requires the aDDllcant for such permit to file a signed statement tfiat he is licensed pursuant to the provisions of the Contracttlr's License Law !Chapter 9, commending with Section 7000 of Dlvision 3 of the B"usiness and Professions Code} or that.he is.exempt thererrom,and tile.basis for the alleged.exemption. Any violation of Section 1031.5 ey any applicant for a permit subjects the applicant to a civilpenalty:Ofnotmore-thanfwehundreddollars{$500}}. • • . .. . . .-· . ,;~@mtn1]m2~.<~"®'ii'!:t;>g11J~~~~~ ·• / r:01f!en.'CompensationDeclaration:fherebyal1irmuncferpenaltyofperjuryoneofthefol!owfngcfeclarations; ~ liave and"will'mainlam a certificate of consent to self.insure for workers" compensation as provid'ed'by Seclion 3700 of'the ta!)(Jr Clxl'e, for Hie pelformance of the work for which this permif is issued. 0 lhffl and vnll maintain w9,iy"' -~as-rw•ired~ Section 3700 of the labor Code, for the pelformance.of the wOtk for '!~is Jllrmit is issued. My workers' compeo5! insurance.carrier. and poff:: numberare:lnsuranceCort"eT~r.f" E". ',:.·::fo(Ca)' <2.r.t PolicyNCl~ /~~ SS'-\ Ei<pirationDate. ...)_,.. /,-. 2<D ttJ This.secllon need not be completed if the. permit is for one hundred doHars ( QO), ortess. 0 Certificate of &emption: I certify that in the performance of the viork for which this pennit is issued, I shall not employ any pe!SOn in any manner so as to become subject to the Workers' Compensation laws of California WARNING: Failure.to seaire workers' compcnsalion coverage is unlawful, and.shl!llsubjectan emptoyerto.Qiminalpenalliesand civil lines.up to.one hundred thousand.d(llla,s (&100,000),in .. wdition to the cost.of complllllllltion, dam.:gl)i; a pravi for rn Secuon 3705 of 1e Labor i:o~terestand attorney's.fees. R$coNTRACTORSIGNATURE -.. w~" I heteby-al1irm that 1 am exempt from Confraclols Lice~ Law far the foUowing:mason: 0 I, as ovmer of lhe property or my employ~ with wag_es as their sole compensation, will do lhe work and the slruc!ure is not intended or offered for safe (.Sec. 7044, Business and Professions Code: The Conlraciors License Ul\'tdoes-not apply to an owner of properly-who buuds,or-iinproves-thereon, and who does such work-himself or through his own emproyees, provided' that sucn iinprovemenlsare not intended or offered for sale. If, however, the buirding or improvement is said within one Y8ilf of compfetion, Iha owner-builder will have the burden of proving that he d1d not buifd or fmprove for !he pucpose of safe). 0 I, as owner of the property, am exclusively conlracling wi!h licensed contractors to construcl-the-projecf {Sec. 7044, Busiitessand Professions-Code:· The Contractor's license law does not app[y to an ovmer of · property who builds or improves thereon, and contracts for such projec!s with contrac!or{s) licensed purauant to the Contractor's license Law). 0 I am exempt under Section ____ ~.usinass and Professions Code for this reason: 1. r personalfy'plan to provid'e !tie majilr labor and matelials. forconstrucfian of IIJe propqsed properly improvement []Yes Do 2.1 (have /have not} signed an application for a.tmikling permit for the proposed viork.. 3.1 have contracted with the following person (lirm) to provide the proposed cons!ruction [include name address f phone I contractors' ficense number): 4..f pfan lo provide.portions oftfie work,. ouf rttave nired.'flie. lolfawihg. pelSOII to coo!diha!e,.supe1Visaand provii:fe llie major.work (incfud'e:name f address r pnone 1 i:ontracfors' license number): 5.1 will providesomeoflhe \'/Ork, bul I haveconltacled (hired) lhefoUowing peraons lo provide lfle workindfca!ed (incfude name/ address/ phone/ type of\'/Ork): :@ri11iJ>' i JJ .~. ,, "' 'Ii > :'§tt > if~':· \: > .. 'iifmtin~;;(;f > ~,,,;: > ' > 11,~'.lf' ,,, 11,~, ~. > > > ~.tr,.~ .~$ > J > > ~,Ji, " >> s the applicant ort!Jitre building occupant required to submit a business,Jlli!!l, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the :>resfey-T anner Hazardous Substance A,ccount Acfl D Yes L_JNo s the appl~nt or future building occupant required to obtain a permit from the air pollution control district or alt!l!!ality management district? Des D No • s the facility to be constructed within 1,000 feet of the outer boundary of a school site? Oves LJNo F AN'f OFTHEANSV'IERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY fi!AY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS L1EETING THE REQUIREf.!ENTS OF THE OFFICE OF :MERGENCY SERVICES AND THEAIR POLLUTION CONTROL DISTRICT . • ender's Name certifythatl have read the application and stafethattheabove Information is correct and thatthe information on the plans is accurate. I agree to comply with all City onllnances and State laws relating to building construction. hereby authorize representative of the City of Carlsbad 1o enteruponthe abwe mentioned property for inspection purposes.I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD lGAINSf ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITYIN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. )SHA:'An OSHA pemitis required for excavations over 5'0' deep and demoli!ion or construction of struclures over3 stones in height :XPIRATION: Eveiy permit issued by 1he Bwlding Official under the provisions of this Code shall expire by flll1italion and become null and void if the building orwolk authorized by such permit is not commenced within 80daysfrom the date of such permitoriflhebuilding orwork autholized by such permit is suspended or abandoned at anytime after the walk is commenced fora period of 180 days (Section 106.4.4 Unifonn Building Code) • ..@S'APPUCANT'SSIGNATURE DATE CIIV Of Carlsbad · Flnal B1lldln1 Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check#: Permit#: Project Name: Address: Contact Person: Sewer Dist: CB090997 ABLATldN FONTIERS-HIGH PILED STORAGE RACKS-COMBUSTIBLES 2210 FARADAY AV #100 Phone: CA Water Dist: CA Date: 08/24/2009 Permit Type: Tl Sub Type: IN DUST Lot: 0 .......................................................................................................................................................... lnspe~~--By: ~~~ Date 1 '\/I Inspected: /--CIJ-O Approved: Af_ Disapproved: __ Inspected Date By: ___________ Inspected: _____ Approved: ___ Disapproved: __ Inspected Date By: Inspected: ____ _ Approved: ___ Disapproved: __ Comments: ------------------------------- -~ · ·city of Carlsbad Bldg Inspection Request For: 08/21/2009 Permit# CB090997 Title: ABLATION FONTIERS-HIGH PILED Description: STORAGE RACKS-COMBUSTIBLES Type:TI Sub Type: INDUST Job Address: 2210 FARADAY AV Suite: 100 Lot: 0 Location: OWNER FARADAY POINTE-CA LLC Owner: FARADAY POINTE-CA LLC Remarks: ANCHOR AND PALLET RACK INSPECTION Total Time: CD Description Act Comments 13 Shear Panels/HD's ~ 14 Frame/Steel/Bolting/Welding I -- _ii_ J/J Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspector Assignment: TP Phone: 6192691925 Inspector: -;2.- Requested By: PHILLIP Entered By: CHRISTINE PCR09067 PENDING ABLATION: REVISIONS TO MECH&; PLUMBING Inspection History Date Despription · Act lnsp Comments 08/17/2009 19 Final Structural CO TP NOTE ON JOB CARD ., 08/20/2009 15:04 6192691925 WINSKI -« -4.,. P.O. Box 23096 • San Di , CA 9ZJ 93 ' IJJNC(al rn..,,.dtoN/oi" Cona 011 l'rq/ect.9 DVBB • 88 c,11) IIMtN ru (IHJ IN"" DAILY FIELD REPORT I AM AUTHOIUZIU IV Tl41 fflDICATIP AiENtv TO f'lllPOIIM 5JJWAL IMSl'iCTlO,. lN THE tAllGONY !;HltnD, II' City 9f SIii lllqo CJ (ALTIIANJ D OSHPD CJ Othwr INSP(C110N DATE PAGE 02 D srRuCNRAl. smL ASSE1111~v (i) 0 0£EP FOUNOATION [J S~AV-APPLIEO 'lll~NG @ @ If OF Tllf Sl'f:mt£MS @ @ ;Js,11tu+H .5 ,~z · · SIGNATUlll .. ,~·· " EsGil Corporation In (J:'artnersnip witli government for (Bui{aing Safety DATE: 6/26/09 0 AP !CANT ( JURIS. JURISDICTION: City of Carlsbad PLAN CHECK NO.: 090997 SET: I 0 PLAN REVIEWER 0 FILE PROJECT ADDRESS: 2210 Faraday Ave. #100 PROJECT NAME: Storage Racks for Ablation Frontiers D D D D D ~ D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for-recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been·completed. Person contacted: Telephone V / Date contacted: (by: ) yt6 #: Mail Telephone Fax In Person A REMARKS: 1. City to field verify that the path o vel from the handicapped parking space to the rack area and the bathroom serving the ra area comply with all the current disabled access requirements. 2. Obtain Fire Department approval. By: David Yao Enclosures: EsGil Corporation D GA D EJ D PC 6/22 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 090997 6/26/09 ..,:, : .... 'I [DO NOT PAY -THIS IS NOT AN INVOICE] ,, VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao PLAN CHECK NO.: 090997 DATE: 6/26/09 BUILDING ADDRESS: 2210 Faraday Ave. #100 BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier storage racks Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance · Bldg. Permit Fee by Ordinance / ...,. I Plan Check Fee by Ordinance 1..-/ Type of Review: 0 Complete Review D Repetitive Fee =8 Repeats Comments: D Other D Hourly EsGil Fee TYPE OF CONSTRUCTION: Reg. VALUE Mod. per city D Structural Only ____ ,Hr.@• ($) 12,000 12,000 $125.551 $81.61 I $70.31 j Sheet 1 of 1 macvalue.doc + PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 09-0997 DATE 6/22/9 ADDRESS 2210 Faraday Av RESIDENTIAL ADDITION• MINOR (<1r,ooo.oo) RETAINING WALL VILLAGE FAIRE OTHER pallet rack PLANNERC~ ENGINEEil~• ----- 11:\ADMIN\COUNTER/PLANNING/ENGINEERING APPROVAI.5 ------ POOUSPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING DATE 6/22/9 DATE ~ (2 <( (u°! 'Carlsbad Fire Department I I l) Plan Review Requirements Category: TI , INDUST Date of Report: 08-05-2009 Name: Address: Permit #: CB090997 ATLAS ;EQUlPMENT CO. SUITEE 5360 EASTGATE MALL SAN DIEGO CA 92121 Job Name: ABLATION FONTIERS-HIGH PILED Job Address: 2210 FARADAY AV CBAD St: 100 BLDG. DEPT COPY Reviewed by: ~ INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0003595 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL rs SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 08/05/2009 By: df Action: AP High Pile Stock Inventory List all products containing plastics stored over 6 feet high. List all aerosol products. List all other products stored over 12 feet high. List all flammable and combustible liquids over 1 container high. Please print or type legibly. Project Number Ceiling Height oL/.o I Jf-,l I Tot!l Square footage of storage including aisles and 15 feet on all sides. I PRODUCTS SHEL YING SOLID EN CAPS-STORAGE PALLETS CARTONS AISLE NON-SOLID ULATED HEIGHT OR BAGS WIDTH RACKS OTHERS N/A R__a..c__K'.5 Q/\R-rl 4411(Y\ {\, UA1CA7ZT /(p ,, I ~ Fire Protection required By California Fire Code Chapter 23 & NFP A 13 A. Commodity Classification: \-l , +\ , F. Sprinkler Temp: ~I;:}. 0 J. Vent Spacing: I ocY.rnA I( B. Sprinklers in Rack: I\. ) / n G. Apply Fig. 12.3 .2.1.5 .I: K. Smoke Detect: N J A C. Sprinkler System Design Curve Fig. No.: I~ , .3 , O , '3 •. \ L. Curtain Boards: /v / A D. Curves: tJ / A H. I ½ Hose: N / 'A M. Curtain Board Size: /\J / I\ E. SprinklerDensilv: l-<-\J..\., / Q) §Oo:,\ .1:7V~tio: J: 50 , I hereby certify all the stora~~!~will be limited as indicated above. Signature Owner or Oc~~.K Date: ~-/ (p '0 L ~ / - City Staff Review: { I Date: This information id available in alternative formHts fnr nMnle with disabilities. To request this information in alternative format call ( FPB-502(Draft March 2008) SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE Business Name Medtronic Ablation Frontiers, LLC Project Address 2210 Farada Avenue Mailing Address 6354 Corte Del Abato, Business Contact Jose Del ado City Carlsbad City Carlsbad Telephone# Telephone# OFFICE USE ONLY UPFP# 2 I O (., 0 f HV# zo-1,,3y.j- BPDATE 68:x: APN# Plan Flle# Project Contact Jose Delgado . 760 43 -48 8x Tha folowfng questions represent tho facility's actlvffies, NOi the specffle proJect description. PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION; OCC~P~CY CLASSl~ATION: lndlcats by circl"ng the Item, wliether your business wtll use, process, or store any of lha following hazardolls materials, If any o t lfemsBmCld, applicant must contact the Flra Protaclion Agency with jurlsdlcllon prier to·plan submittal. • 1. Exploslve or Blasting Agents 5. Organic Peroxides 9. Water Reaclives ~ r~ ~-'9')!,> ~ == . . ~o,To,JoMam~ ::~:;1e~ 4. e . 8. Unslable Rsacllves 12. -HAZA . TERIALS DIVIS! NS HMD : If lhe answer to any of too .questions syes,ep lcantmustcon!act uni.yo an o aza ous • sDlvision.1255lmperialAvenue, floor, nOJego,CA92101. Call (619) 338-2222 prior to Iha issuam;e of a building petmlt. . . . FEES ARE REQUIRED.· · . · Expected DateofOocupaocy: 7/29/2009-,·•-•••·~·-··""·"'" ....... ~,m~, .. _q CalARP Exea.,t 1. ~S ~ ls your business lisled on lherevarses!deofihls fonn? (check.au that apply}. ~ . :, _ .. _: .. ':·) ····;;;;·~~l fn!Uals · ~ 181 0 Wlll your business dispose of Hazardous SUbstances or Medical Waste In any amourit? '1 u · '-''-' ·, '-'=":: 0 CatA&P Required ~ j,P!J. )if{ $ · WIii your bUslness store er handle Hazardous Substances In quantities equal lo or Eireatar than 1/ ] {, ,I _ . 55 gallons, 500 ll:°unds, 200 cubic feet, or carclno_gens/reproducliva loxlns in any qu~flty? A p R 1 3 2009 -Da-te---.-!1' .... ,nifia-ls-- 4. D "12lJ Will )'OOf" busi~ use an e)(fsllng or Install an underground storage tank? // · · . /1 • 5. D 181 Wilt )'OOf" business store or handle Regulated Substances (CalARP)? u ,-, .... .., _ .. D ~ Complete 6. 0 181 Will your business use or lnstaR a Hazardous Waste Tank System (T1lle 22, Article.10)? [ \./;::::·-;I :f':~/?!P fi,1; fir i ;;:,'~__,,,....I .,../ ~--. )k,··i,",·, · ., · .. , · , •. ,',:Dale fl Initials .,1.-·~· .. ···1'~··,,···-t~~·n:··· ~-1i • PART Ill: SAN tllEGO COUNTY AIR POLLUTION CONTROL PJSiRICT: If 1he answer to any of th~· q-~~li~~ '~cw'is·yes";"tijl'"i,,rcaiiFmut:rt•funtact lhe f,Jr PolliUon Control District (APCbX 1o'f24 Old Grove Road, san Diego, CA 92131-1649, lelephone (858} 586-2600 prior lo the Issuance cf a building or demolitlon permit Note: If Iha answer to questions 3 or 4 is yes, applicant must alSQ submit an asbestos notlflcalion fonn to the APCD at least 10 working-days prior to commencing demolitlon or renovation, except demolllion pr .mnovation of residential structures of four units or less. Coolact Iha APCD fur more infonnation. YES NO . ' . 1. D E8J Will the 6!.lbject facillty or construction· acllvfties friclude operafions or eqtipmoot that emit or am capable of emitting an air contaminant? (See the APCD factsheet at http:/JwwW.sdapcd.org/lnfoftactsfpenn!lsmf, and !he rrst of t)'pical equipment requiring an APCD permit on the reverse side of this from, ContacfAPCl:Hfyou have any questions). • . 2. 0 0 (ANSWER ONLY IF QUESTION 1 IS YES} Win the 6llblect facility be located within 1,000 feet of the outer boundary of a school (K ihrough 12)? (Publlc and priwls schools may be found after searcJi of lhe Catifomla S<:bool Direc!ory at h!lp;/{w,w{.C!le.ca,gov/re/sdl; or contact the appropriate school district). · • 3. D ~ Will there be renovalion lhet lnvol118S hendllng of any li'iable asbestos materfals, or disturbing any ma!.erlal that contains non-friable asbestos? 4. d 181 WIii lhere be demolition Involving the removal of a load $Upporling structural member? 0 ·5! I /Q t-09 Dale FOR OFFICIAL USE; ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _________ ......; ____ __,,--..:._ __________ _ BY: ______________________ _ DATE: __ ~-----,--- EXEMPT OR HO~ INFORIIAnotl REQIJllED RELEA8l:D FOR OCCUP.ANCY COUNTY-HMO APCD . APCO COUNJY-HMO APCD ' . HM-9171 (04/07) Councy ofSan.Diego-DBII-Hazsrdaus ~a!erials Divi&ion ., , By ..... , .. G .... OHANIAN .... RAdK DE~IdN & ENGINEERINd do. 412 WE~T BROADWAY, ~UITE :/1204 SHEET NO ............ L ........ .. ' DATE ...... §:;::.U.::2~ ...... . GLENDALE, dA. 91204 JOB NO .... ~.R.::.H:?.J .. ?. .. . SUBJECT. ......................... . TEL:(818)240-3810 FAX:(818)240-3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: ABLATION FRONTIERS 221 0 FARADAY AVE., #1 00 CARLSBAD, CA. 9201 1 PER CBC 2007 EDITION STORAGE RACKS CAPACITY: 3000 # / LEVEL AT TYPE "A" 500 # / LEVEL AT TYPE "B" CALCS. 1 THRU 6 DRAWINGS: RD-14212 , BY ... \ .. G .... OHANIAN .. .. ,DATE ...... ~.:: .. U.::9.~ ...... . RACK DE~IdN & ENdINEERINd do. 412 WEST BROADWAY, ~UITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO ............ ?. .......... .. JOB NO •.. B.P..::.1.±~J..?. .. . • SUBJECT .......................... . 120" 120" 96" 144" & 96" 96" r 4 1/8" BEAM r 1 4 1/8" BEAM H 3 3/8" BEAM 5 5/8" 144" LONG BEA Jl 3 3/8" BEAM .-----ro ~3 "'" PIN CONN. co l/4 PIN CONN.~ "'" 1st LEVEL ro "'" TUNNEL .,,. ....... .. . . . -.. .. .. . . .. . ........................ TYPE "A" 42" 42" nn 42" n -- co 3 3/8" 96" LONG BEAM "'" ---·ro CONN. "<I" /3 PIN TYP. L- ro "'" ~ .. -. -~ ... ... .. .. .. .. -·· .....•.. TYPE "A" • 144" '.......-' ~ 13 3/8" BEAM -:.i-N I ,,-_3 PIN CONN. / TYP. ~f--111:=======ill~ N -'.--lt=======il===i-~ ~ "'" '.-lt::=====::::ll~ ~~ N -111:=======ill~ ~ N ro-1t======::::i1~ l.12 -;:::J.j~;;;;:;;;;;;;;;;;;;;;;;;;;;;;;;;;;:;;;;;;;;;;il;;;;;;i-~ It-~ :··~ •:•-:r. ·-····· ,·),,.·-··:,• .. .,•;·•. :, •.• ·~-·-... .,_ .. 0 SIDE VIEW TYPE "B" SIDE VIEW BEAM M= 144"x1 .7 K=3 1 "K 8 31 "K SR= 33 = .93<1.49 6.= 5xWxL3 = 46"< 144=.80" 384xlx xE · 180 BEAM M= 120"x1.7K=26"K 8 26"K SR= 33 = .77<.91 6. = SxWxL3 = 58"< 120 = 67" 384xlx xE · 180 · 3000 #/ LEYEL+25% IMPACT LOAD 1700 #/ BEAM fCLx [Q [ 2 3/4" [ {G,x CQ ! 2 3/4" l lx=4.34 Sx=1.49 Fy =55 KSI. lx=1.98 Sx=,91 Fy=55 KSI. . ~ .. -. 24" n -~ , BY .. :, ... G .... OHANIAN ... . _DATE ...... ~.::..1.1.::9.~ ...... . SUBJECT. ......................... . BEAM M= 96"x1.7 K =21 "K 8 21 "K SR= 33 = .62<.66 l:J.= 5xWxL.-s = 49,,<~ = _53,, 384xlx xE · 180 SEISMIC DESIGN RAdK DE~IGN & ENGINEERING do. 412 WEaT BROADWAY, ~UITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO ............ ~ ........... . JOB NO •... ~.P..::.1.:1:?J.~ .. . 3000 #/ LEVEL+25% IMPACT LOAD 1700 #/ BEAM ~ui. CQ [ 2 3/4" [ lx=1.21 . Sx=,66 Fy=55 KSI. Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33. 1342 Longitude = -117.2776 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D -Fa = 1.04 ,Fv = 1.564 Period Sa (sec) (g) 0.2 1.197 (SMs, Site Class D) 1.0 0.681 {SM1, Site Class D) V= ~ x W CBC 2007, PER RMI SPECS. RX 1 .4 WORKING ( ) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.1342 Longitude = -117.2776 STRESS ASCE 7-05 SEC. 15.5.3 S05 =.8 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ ~ LL. LOAD PER COLUMN TYPE "A" L.L.=..£x 3x3 K =3.0 K 3 2 COL. W=.? + 3.0L = 3.2 K "'b.L. .L. y = .8x1x3.2=.3oK LONGIT. 6X 1 ,4 y = .8x1 x3.2 _ 45 K TRANS. 4X1 ,4 -• TYPE "8" w=.2ti.c: 1.oL.E 1 .2 K y = .8x1 x1.2 = _ 11 K LONGIT. 6X 1 .4 y = .8x1x1.2-17 K TRANS. 4X 1 ,4 -• LONGIT. SEISMIC 1------+--.15 K >-----+--.09 K 1------+--.06 K .30 K M = . 11 Kx24" = 1 "K COL. 2 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D -Fa = 1.04 ,Fv = 1.564 Period (sec) 0.2 1.0 3 "K 6 "K 7 "K Sa (g) 0.798 (SDs, Site Class D) 0.454 (SD1, Site Class D) 3 "K 6 "K 7 "K , BY ....... G .... OHANIAN .. .. RACK DESIGN & ENGINEERING do. 412 WEST BROADWAY, ~UITE ;¥204 SHEET N0 ........... :1: .......... .. PATE ...... ~.:::.U.::9~ ...... . QLENDALE, dA. 91204 JOB NO ... B.P..::.H:~.L?. .. . C SUBJECT. ......................... . TEL:(818)240-3810 FAX:(818)240-3813 COLUMN ANALYSIS COLUMN AT TYPE "A" v r st 3" ~-~rb~ [~ Fy=55 KSI A=.62 Sx=.68 rx =1.2 ry=1.1 P= 3x3 K =4.5 K 1 00% LOAD 2 COL COMBINED STRESS RATIO f...+.M_ = 4 ·7 +l = .65<1.0 Pa Max 14 22 COLUMN AT TYPE "B" r1 5/8" r~~ , '' I') J:-c [b Fy=SsKs1 A=.43 Sx=.36 rx=1.1 ry=.63 P= 6x.5 K =1.5 K 100% LOAD 2 COL W=.?L+ 1.SL= 1.7 K 7).. .L. COMBINED STRESS RATIO f...+.M_ -1.7 +-1--27<1 0 P0 M0 ; 9 12 -· · BASE PLATE 7-(4.7x3") ANCH. TENSION= 6,, =O ANCHOR SHEAR = -~O = .15 K (2)-1/2"¢ ANCHORS HILTI KWIK BOLT-TZ ESR-1917, OR APPROVED EQUAL SPECIAL INSPECTION IS REQUIRED .Kl _ 48x 1. 7 _ 68 rx -1.2 - .Kl -42 -3a r-u-y • .Kl_ 24x1.7 _37 rx -1.1 - .Kl -42 -57 ry -.63 - Max =Sx .Fb= 12 "K 2 Fe= .z:r.:xr_= 62 ( Kl )2 rx F n=Fy (1-:~ )=43 KSI Pn= Fn xA= 27 K P _ Pn _ 14 K a-1.92 - 2 Fe= .z:r.:xr_= 64 ( .Kl )2 ry Fn=Fy(1-:~)=43KSI Pn=Fn XA= 19 K P Pn -9 K a= 1.92 - 4.7K 7:) :4 . : .. 6" 1 'BY ... :-.. G .... OHANIAN ... . DATE ...... ~.:::.U.::Q~ ...... . SUBJECT. ......................... . RAdK DE~IGN & ENGINEERING do. 412 WEST BROADWAY, ~UITE #204 QLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO ........... :? ............ . JOB NO •.. B.P..::.1.1.~J.?. .. . MOMENT AT BEAM CONNECTION 7 /16"¢ RIVET A = .1 Fy = 79 KSI Va = .1 x79x.4 = 3 K Ma =3Kx4"x1.33=16"K CONN. Ma = 3 Kx2x4"x 1.33 = 32 "K CONN. 3 PIN CONN. 4 PIN CONN. 1st LEVEL ( 6.5 "K 6.5 "K _) I I ~ 7"K ADJACENT TO TUNNEL OVERTURNING TYPE "A" Mor= .45Kx2x144"x.5x1.15 =75"K MR = 3.2 Kx42" = 134 "K NO UPLIFT TYPE "8" Mor= .17Kx2x144"x.5x1.15 =28 "K MR = 1.2 Kx24" = 29 "K NO UPLIFT TOP LEVEL LOADING (100% LOAD) L.L.=1x3 K=3 K W=,2r,,L; 3L.L:= 3.2 K y _ .8x1x3.2-45 K TRANS. 4X 1 .4 -• Mor=.45Kx144"= 65 "K MR =3,2 Kx21 "= 67 "K NO UPLIFT TOP LEVEL LOADING (100% LOAD) LL.= 1 x.5 K=.5K W=,? +.5 L=.7 K 7),L, L V = .8x1x.7 = _10 K TRANS. 4x1 ,4 Mor=·10Kx144"= 14"K UPLIFT= 14-8 = .25 K 24" • , · BY' ... :: .... 9.~ ... 9.t!Af':!!.~.t:L .. RAdK DE~IGN & ENGINEERING do . 412 WEST BROADWAY, ¢UITE #204 SHEET NO ........... § ............ . .DATE ...... §::::.U.::Q~ ...... . , SUBJECT. ......................... . CfLENDALE, dA. 91204 JOB NO .... ~P..:::J.1.~J~ .. . TEL:(818)240-3810 F.AX:(818)240-3813 LOAD TO DIAGONAL P = .45Kx2x ..5..Q. = .57 K 42 Fy=55 KSI A=.31 rx=.48 Q=.74 L= 50" CHECK WELDS Fa= 12.8KSI Pa= 4.0 K 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x. 707x70x.3 = 5. 7 K CHECK SLAB 4700 -g 40' 500 -. -v1"rn3=36" 9.4x144=1353 a" M= (11 ·5 )\500x 1-x12= 2755 "# 12 2 S= 12x52 = 50 6 2l 55 = 55 < 1. 6 Y2500 =80 BOTH SIDES 1YP. 1/B 1.5" DI ' j/D 1%" ~mx t=.07" I 0 1 ..----7 I ~--Jo, , o I I > I / D 1YP 1/8 1.5" 47001! i · ... ' . ' 5" CONCRETE SLAB 2500 PSI. CONC. 500 PSF. SOIL .... ·: : ~ :--·- 4 i· >> . .-:~-· -:~ 4,4 " ~ -.~ : 36" 6.5" 11.5" 18" ll ~ \~ ,KL~USBRUCKNER lJ . )} AND ASSOCIATES 11 I] I] 11 Ii I} 11 I. I: I: I I I I I I I Suite 100 Carlsbad, CA ·92010 High-Piled Combustible Storage Report Rev 1.0 June 8, 2009 4105 Sorrento Valley Blvd. San Diego, CA 92121 Tel: (858) 677-9878 Fax: (858) 677-9894