Loading...
HomeMy WebLinkAbout2210 Faraday Ave; 120; CBC2016-0090; PermitPrint Date: 05/09/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2210 Faraday Ave, 120 BLDG-Commercial 2121205500 $6,000.00 Commercial Permit Work Class: Tenant Improvement Lot#: Reference #: Construction Type Bathrooms: Orig. Plan Check#: Plan Check#: Description: GEN MARK: HIGH-PILE STORAGE RACKS APRX 1,850 SF AREA Owner: CARLSBAD 2210 LLC 8100 Maplewood Ave E, 220 GREEWOOD VILLAGE, CO 80111 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $ 217.80 Total Payments To Date : $ 55.64 {city of Carlsbad Permit No: CBC2016-0090 Status: Applied: Issued: Permit Fina led: Inspector: Final Inspection: Contractor: Closed - Expired 12/22/2016 RAYMOND HANDLING SOLUTIONS INC 9939 Norwalk Blvd SANTA FE SPRINGS, CA 90670-3321 562-944-8067 Balance Due: AMOUNT $79.48 $55.64 $41.00 $39.00 $1.00 $1.68 $162.16 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees /exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING Ccityof Carlsbad JOB ADDRESS 2.21'0 CTf,PROJECT # LOT# Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov SUITE#/SPACE#/UNrT# Av I::'. n.v PHASE# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) EXISTING USE GARAGE (SF] PATIOS (SF) DECKS (SF) FIREPLACE ~-S-\ YES0 PROPERTY OWNER NAME ADDRESS Cl1Y Ci.YI sb o< PHONE s~ ).-PHONE EMAIL CONTRACTOR BUS. NAME p ... o - CONSTR. TYPE acc. GROUP V---l'., r>---S· AJR CONDITIONING NoO vesONoO FIRE SPRINKLERS YES0N00 STATE ZIP C-A.. FM DESIGN PROFESSIONAL S1\l--VCTV 12--A'f M,c 11.i 1) ADDRESS \ PHONE . 11"\. EMAIL ST6 ~- STATE ZIP •Y2..-'bD.1 STATE UC.# ADDRESS qcc~q Cl~. 2>ll'I-\., Fe PHONE <"/iUO· 112--"68:S°B EM All STATE LIC.# 'i> ZIP OA. '10 10 FM QI (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to_construct. alter, improve, demollsh or repair any structur , prior o its issuance, also requires the applicant for such per_m1t to file a s1Med statement that he 1s licensed pursuant to the provisions oft~e Contractor's license Law {Chapter 9, comme.nding with Secti9n 70_00 of Division 3 of the Business and Professions Code} or that he 1s exempt therefrom. and the basis for the alleged exemption. Any v1olat1on of Section 7031.5 by any applicant for a permit subJects the appbcant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the labor Code, for the perfonnance of the work for which this pennit is issued. I have and will maintain workers' compensation, as rreQuired by Section 3700 of the labor Code, for the performance of!1e work for which. this perm? issued. My workers' compensation insuran_:: carrie~ and policy numberare:lnsuranceCo. Kavs\c:i -\J~A. lr\L· Po!icyNo. LU<'.-~01S: 1~-0=\= ExplrationDate 4-c,( 2..017 This section need not be completed if the permit is for one hundred dollars ($100) or less. D Certificate of Exemption: I certify that in the performance of the work for which this permit is issLJed, I shall not employ any p_erson in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the labor code, interest and attorney's fees.:----:-;/;~P:, 2$ CONTRACTOR SIGNATURE / hereby affirm that I am exempt from Contractor's Ucense Law for the following reason· D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that sLJch improvements are not iritended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exdusively contracbng with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt Linder Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed pro~rty improvement 0Yes 0No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (finn) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but! have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): ~ PROPERTY OWNER SIGNATURE 0AGENT DATE COMPLETE THIS SECTION FOil NON•REStDENTfAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and preventon program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act'? Yes No Is the applicant or future building occupant required to obtain a pem,it from the air pollution control district or air quality management district? Yes ~ Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the appllcatlon and state that the above lnfonnatlon Is conectand that the infonnation on the plans is accurate. I agree to complywth all City ordinances and State laws relating 1D builclng construction. I hereby authorize rep-esentative of the City of Garlsbad to enteru!X)n the atxive mentioned property for inspection f)JtlXlses. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA M OSHA permit is required for excavations ayer 5'0' deep and derrdltion or ccnstruction of structures over 3 stories in hei;]hl. EXPIRATION: Every permit is.sued by the Building Official under the provisions of this Cooe shall expire by limitation and beOJme null and vt1kl Wthe DJilding orv.or1< authorized by sudl permit is not oommenced 'MIilin 100 days from the date of such permit or if the buik:Hng or'l,OfK authorized by sudl permit is suspended or abal"OO'led at anytime after the 'M'.X'k is commenced for a period of 100 days (Section 100.4.4 UnOOrm Building Code). ,l!5 APPLICANT'S SIGNAT\JRE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. UC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL TO: CONTACT (Listed above) CONTRACTOR (On Pg. 1) OCCUPANT (Listed above) MAIL/ FAX TO OTHER:---------------- A$ APPLICANT'S SIGNATURE ASSOCIATED CB#,------------- NO CHANGE IN USE I NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION DATE ZIP ~~ ~ CIT Y OF CARLSBAD CBC2016-0090 2210 FARADAY AVE # 120 Building Division INSPECTION RECORD GENMARK: HIGH-PILE STORAGE RACKS APRX 1.850 SF AREA 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE K~PT ON THE JOB 0 CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION 2121205500 12/22/2016 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Building AND CLICK ON "Request Inspection" CBC2016-0090 DATE: If "YES" is checked below that Division's approval is required rior to re ues_tmg a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to 760-602-8560, email to bid ins ections@carlsbadca. ov or bring in a COPY of this card to: 1635 Faraday Ave .• Carlsbad. NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Notes Planning/Landscape 760-944-8463 Allow 48 hours CM&/ (Engineering Inspections) 760-438-3891 Call before 2 pm Fire Prevention 760-602-4660 Allow 48 hours Type of Inspection Type of Inspection CODE II BUILDING Date Inspector CODE II ELECTRICAL Date Inspector #11 FOUNDATION #31 D ELECTRIC UNDERGROUND D UFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 0 ELECTRIC SERVICE O TEMPORARY D GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #53 ELEC/CONDUIT/WIRING #11 POUR STRIPS #39 FINAL #11 COLUMN FOOTINGS CODE II MECHANICAL #14 SUBFRAME O FLOOR D CEILING #41 UNDERGROUND DUCTS & PIPING #15 ROOF SHEATHING #44 0 DUCT & PLENUM O REF. PIPING #13 EXT. SHEAR PANELS #43 HEAT-AIR COND. SYSTEMS #16 INSULATION #49 FINAL #18 EXTERIOR LATH CODE II COMBO INSPECTION #17 INTERIOR LATH & DRYWALL #81 UNDERGROUND (11,12,21,31) #51 POOL EXCA/STEEL/BOND/FENCE #82 ·DRYWALL,EXT LATH, GAS TES (17,18,23) #55 PREPLASTER/FINAL #83 ROOF SHEATING, EXT SHEAR (13,15) #1.9 FINAL #84 FRAME ROUGH COMBO (14,24,34,44) CODE II PLUMBING Date Ins ector #85 T-Bar (14,24,34,44) #22 0 SEWER & BL/CO D Pl/CO ~~~~~~---'-~~~~~~t--~~~--+~~~~~~ #89 FINAL OCCUPANCY (19,29,39,~9) #21 UNDERGROUND D WASTE D WTR FIRE Date 1.ns ctor #24 TOP OUT D WASTE D WTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 D GAS TEST D GAS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL A/S FINAL CODE It STORM WATER F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH -IN #605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITIEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURETEST #610 VERBAL WARNING MEDICAL GAS FINAL EV 10/2016 EsGil Corporation • In <Partners nip witfi government for <Bui{tfing Safety DATE: 1/5/2017 JURISDICTION: City of Carlsbad PLAN CHECK NO.: C2016-0090 PROJECT ADDRESS: 2210 Faraday Ave. PROJECT NAME: Storage Racks for Genmark SET: I .D AP~LICANT b--:11'.JRIS. D PLAN REVIEWER D FILE [2'.] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [2'.] EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacte~ L] Telephone#: Date contacted: ·~ ' ) Email: Mail Telephone Fax In Person [2'.] REMARKS: 1. Fire Department approval is required. 2. City to field verify that the path of travel from the handicapped parking space to the rack area and bathrooms serving the rack area comply with all the current disabled access requirements. By: David Yao Enclosures: EsGil Corporation D GA D EJ D MB D PC 12/27/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 . Clty of Carlsbad C2016-0090 1/5/2017 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: C2016-0090 PREPARED BY: David Yao BUILDING ADDRESS: 2210 Faraday Ave. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION (Sq.Ft.) Multiplier rack Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. ~e_~_mi_t Fee_ by_£)_rd_ina_nc: . -• I Type of Review: 0 Complete Review D Repetitive Fee ~~~ ~~.;] Repeats Comments: D Other D Hourly EsGil Fee DATE: 1/5/2017 Reg. VALUE ($) Mod. per city 6,000 6,000 $79.11 I $51.42! D Structural Only 1-------;1 Hr. @ * $44.301 Sheet 1 of 1 macvalue.doc + Structural Concepts Engineering 1815 Wright Ave La Verne, Ca. 91750 Tel: 909-596-1351 Fax: 909-596-7186 Project Name: GENMAl<K FARADAY Pr~ect Number: Q-102516-2LV Date : 10/26/16 Street Address: 2210 FARADAY AVE, SUITE 120 City/State : CARLSBAD, CA 92008 Scope of Work : STORAGE !<ACK CBC2016-0090 2210 FARADAY AVE # 120 GENMARK HIGH-PILE STORAGE RACKS APRX 1.850 SF AREA 2121205500 12/22/2016 CBC2016-0090 -c.) OCT 2 8 2016 Structural Concepts ~~ Engineering --!;:/ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV TABLE OF CONTENTS Title Page ... Table of Contents .... 2 Design Data and Definition of Components ... 3 Critical Configuration . 4 Seismic Loads ... 5 to 6 Column. 7 Beam and Connector ..... . 8 to 9 Bracing .. 10 Anchors ... 11 Base Plate ... 12 Slab on Grade .. 13 Other Configurations .. 14 GENMARK FARADAY TYPE A Page "7-of l 'f I 0/25/2016 Structural Concepts ~;j Engineering --<~ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV Design Data 1) The analyses herein conforms to the requirements of the: 2012 !BC Section 2209 2013 CBC Section 2209A ANSI MH 16.1-2012 Specifications for the Design of Industrial Steel Storage Racks ''2012 RMI Rack Design Manual" ASCE 7-10, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy=SS ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy=55 ksi Al! other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The existing slab on grade is 5" thick with minimum 2500 psi compressive strength. Allowable Soil bearing capacity is 750 psf. The design of the existing slab is by others. 6) Load combinations for rack components correspond to 2012 RMI Section 2.1 for ASD level load criteria Definition of Components Frame Height A ~: :li====:::lii:±:======lt Beam Product Spacing ~=~~~~b:::!:~=dt Beam Length Front View: Down Aisle (Longitudinal) Frame Column =~ Beam to Column Connector =~ Base Plate and Anchors ~ GENMARKFARADAYTYPEA Page ·; of l L(' Panel Height l'====al_J_ I..-... Frame .-1 I Depth -1 Section A: Cross Aisle (Transverse ) Frame Horizontal Brace Diagonal Brace I 0/25/2016 Str~ural \..,oncepts ~4 Engineering ·--sd 1200 N. Jefferson Ste Ste FAnaheim CA92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV Configuration & Summary: TYPE A SELECT1VE RACK T 34" 144" + - 100" Seismic Criteria # Bm Lvls Ss=l.069, Fa=l.072 2 Component Column Fy=55 ksi Column & Backer None Beam Fy=55 ksi Beam Connector Fy=55 ksi Brace-Horizontal Fy=55 ksi Brace-Diagonal Fy=55 ksi Base Plate Fy=36 ksi Anchor 1 per Base Slab &Soil Level I Load** Per Level BeamSpcg 1 1,000 lb 100.0 in 2 1,000 lb 34.0 in ** Load defined as product weight per pair of beams Notes I GENMARK FARADAYTYPE A 144" 36" 1 .-f-42" + **RACK COLUMN REACTIONS ASDLOADS AAZ<IL DL= 75 lb AAZ<IL LL= 1,000 lb SEISMIC AAZ<IL Ps=+/-973 lb BASE MOMENT= 0 in-lb Frame Depth Frame Height # Dia onals Beam Length Frame Type 42in 144.0 in 3 96in Single Row Description STRESS Hannibal IF301+3x3x14ga P=1075 lb, M=10525 in-lb 0.3+0K None None N/A HMH 24160/2.5" Face x 0.06" thk Lu=96 in I Capacity: 1883 lb/pr 0.53-0K Lvl 1: 3 pin OK I Mconn=4956 in-lb I Mcap=l2691 in-lb 0.39-0K Hannibal 1-1/2xl-1/2x16ga O.O+OK Hannibal 1-1/2xl-1/2x16ga 0.06-0K 8x5x3/8 I Fixity= O in-lb 0.17-0K 0.5" x 3.25" Embed HILTI KWIKBOLTTZ ESR 1917 Inspection Reqd (Net Seismic Uplift=417 lb) 0.342-0K 5" thk x 2500 psi slab on grade. 750 psi Soil Bearing Pressure Brace 36.0 in 48.0 in 48.0 in Total: I Story Force I Story Force Transv Longit. 1221b 931b 1631b 1241b 285 lb 217 lb Page 'f of \lf Column I Column I Axial Moment 1,075 lb 10,525 "# 5381b 1,057 "# 0.12-0K Conn. Beam Moment Connector 4,956 "# 3 pin OK 1,273 "# 3 pin OK I 0/25/2016 Structural Concepts ~4 Engineering --~ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV Seismic Forces Configuration: TYPE A SELECTIVE RACK Lateral analysis is performed with regard to the requirements of the 2012 RMI ANSI MH 16.1-2012 Sec 2.6 & ASCE 7-10 sec 15.5.3 Transverse (Cross Aisle) Seismic Load V= Cs*Ip*Ws=Cs*lp*(0.67*P*Prf+D) Vt Cs!= Sds/R = 0.1910 Cs2= 0.044*Sds = 0.0336 Cs3= 0.5*51/R = 0.0516 Cs-max= 0.1910 Base Shear Coeff=Cs= 0.1910 Cs-max* Ip= 0.1910 Vmin= 0.015 Elf Base Shear=Cs= 0.1910 Ws= (0.67*PLm * PL)+DL (RMI 2.6.2) = 1,490 lb vtransv=Vt= 0.191 * (150 lb+ 1340 lb) Etransverse= 285 lb Limit States Level Transverse seismic shear per upright Leve! PRODUCT LOAD P P*0.67*PRF1 DL hi wi*hi 1 2 1,000 lb 1,000 lb 670 lb 6701b sum: P=2000 lb 1,340 lb Lonqitudinal (Downaisle) Seismic Load Similarly for longitudinal seismic loads, using R-6.0 Ws= 751b 751b 150 lb 100 in 134in W=1490 lb (0.67 * PL,"* P) + DL 74,500 99,830 174,330 PRF2- Ss= 1.069 51= 0.413 Fa= 1.072 Fv= 1.587 Sds=2/3*Ss*Fa= 0.764 Sdl=2/3*Sl *Fv= 0.437 Ca=0.4*2/3*Ss*Fa= 0.3056 (Transverse, Braced Frame Dir.) R= 4.0 Ip= 1.0 PRfl = LO Pallet Height=hp= 48.0 in DL per Beam Lvl= 75 lb Fi Fi*(hi+hp/2) 121.8 lb 15,103·# 163.2 lb 25,786-# 2851b J:=40,889 :.o I ,:,I E3 ,,.,I 8 :sl=Sdl/(T*R)*0.67= 0.1457 = 1,490 lb (Longitudinal, Unbraced Dir.) R= 5.0 h·I 1:""' ,,.,19 Cs2= 0.0336 Cs3= 0.0344 Cs-max= 0.1457 Level I 2 PRODUC LOAD P 1,000 lb 1,000 lb Cs=Cs-max*lpo:: 0.1457 T= 0.50 sec I Vlong= Elongltudinal= P*0.67*PRF2 670 lb 6701b 0.1457. (150 lb+ 1340 lb) I 217 lb limit Slates LI/I'd LM/Ji"t.. seinmc $MM per upri{Jht DL 751b 751b hi lOOin 134 in wi*hi 74,500 99,830 E::Jr:1 [3 Fi 92.7 lb 124.3 lb F~ont View B sum: 1 340 lb 150 lb W=1490 lb 174 330 217 lb ~~~~~=======~====~========~~======~~~====~~~~~~= GENMARK FARADAYTYPE A Page 5' of ( 'f I 0/25/2016 Structural Concepts ~~~ Engineering --~ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV Downaisle Seismic Loads Configuration: TYPE A SELECTIVE RACK Determine the story moments by applying portal analysis. Toe base plate is assumed to provide no fixity. Seismic Story Forces Vlong= 217 lb Vcol=Vlong/2= 109 lb Fl= 931b F2= 124 lb F3= 0 lb Seismic Story Moments Typical frame made of two columns ' = r=-::i.·· .. · ·. ·.· [771.· ' r--=L .. · [771. •·. '= ... · .. · ..... ~ ~ ~·~ r:=...J'L.:::l I . I ' = r= =.· ····.:r=.···· =:=.···· -+ c:::.:::.J L...:::J" i.:::::..:J I ~ c:::::..:J I~ Conceptual System Typical Frar:1e made o( two column> '_r-: __ - Mbase-max= 0 in-lb <=== Default capacity hi-elf= hl -beam clip height/2 Mbase-v= (Vcol'hleff)/2 = 97 in = 5,262 in-lb <=== Moment going to base Mbase-eff= Minimum of Mbase-max and Mbase-v = 0 in-lb PINNED BASE ASSUMED M 2-2= [Vcol-(Fl)/2] 'h2 M 1-1= [Veal* hleff]-Mbase-eff = (109 lb' 97 in)-0 in-lb = 10,525 in-lb = (109 lb -62.2 lb]'34 in/2 = 1,057 in-lb Mseis= (Mupper+Mlower)/2 Mseis(l-1)= (10525 in-lb+ 1057 in-lb)/2 = 5,791 in-lb Mseis(2-2)= (1057 in-lb+ O in-lb)/2 = 528 in-lb Summary of Forces LEVEL 1 2 hi 100 in 34in Axial Load Column Moment** 1,075 lb 10,525 in-lb 538 lb 1,057 in-lb Mconn= (Mseismic + Mend-fixity)*0.70*rho Mconn-allow(3 Pin)= 12,691 in-lb **all moments based on limit states level loading Mseismic** 5,791 in-lb 528 in-lb GENMARK FARADAY TYPE A Page {; of l 'f Mend-fixity 1,290 in-lb 1,290 in-lb Veal h2 ,. 1~ - h1 h1eff 11 Beam to Column Elevation rho= 1.0000 Mconn** Beam Connector 4,956 in-lb 1,273 in-lb 3 pin OK 3 pin OK I 0/25/2016 COi Structural Concepts ~4 Engineering ·----'--~ 1200 N. Jefferson Ste Ste F Anaheim CA92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-ZLV Column (Longitudinal Loads) Configuration: TYPE A SELECTIVE RACK Section Properties Section: Hannibal IF3014-3x3x14ga Aeff = 0.643 inA2 Ix = 1.130 in/\4 Sx = 0.753 in"'3 rx = 1.326 in nf= 1.67 Iy = 0. 749 inA4 Sy = 0.493 in A 3 ry = 1.080 in Fy= 55 ksi Kx = 1.7 Lx = 98.8 in Ky= 1.0 Ly= 36.0 in Cb= 1.0 r-3.00:in~ -r y-·-r·-·-y 3.000 in Cmx= 0.85 E= 29,500 ksi Loads Considers loads at level 1 COLUMN DL= 75 lb Critical load cases are: RMI Sec 2.1 10,075 in JI ~0.75in _j_ COLUMN PL= 1,000 lb Load Case 5:: (1+0.105*Sds)O + 0.75*(1.4+0.14Sds)*B*P + 0.75*(0.7*rho*E)<= 1.0, A50 Method Meal= 10,524 in·lb axial load coeff: 0.791154 * P seismic moment coeff: 0.5625 * Meo/ Sds= 0.7640 Load Case 6:: (1+0.104*5ds)O + (0.85+0.145ds)*B*P + (0.7*rho*E)<= 1.0, ASO Method 1 +0.lOS*Sds= 1.0802 axial load coeff: 0.66987 seismic moment coeff: 0.7 * Meo/ 1.4+0.14Sds= 1.5070 By analysis, Load case 6 governs utilizing loads as such 1+0.14Sds= 1.1070 Moment=Mx= 0.7*rho*Mcol 0.85+0.14*Sds= 0.9570 B= 0.7000 rho= 1.0000 Axial Anal sis Axial Load=Pax= 1.10696*75 lb+ 0.95696*0.7*1000 lb = 7531b = O. 7 * 10524 in-lb = 7,367 in-lb KxLx/rx = !.7*98.75"/1.326" = 126.6 Fe= nA2E/(KL/r)maxA2 = 18.2ksi Pn= Aeff*Fn = 11,680 lb P/Pa= 0.12 Bendin Anal sis Check: P/Pa + Mx/Max $ 1.0 Pno= Ae*Fy < 0.15 = 0.643 in A 2 *55000 psi = 35,365 lb Max= My/Qf = 41415 in-lb/1.67 = 24,799 in-lb µx= {l/[l-(l'lc*P/Pcr)]Y-1 KyLy/ry = 1 *36"/1.08" = 33.3 Fy/2= 27.5 ksi l'lc= 1.92 = {l/[l-(!.92*753 lb/11674 lb)JY-1 = 0.88 Combined Stresses Pao= PnolQc = 353651b/l.92 = 18,419 lb Fe < Fy/2 Fn= Fe = nA2E/(Kljr)maxA2 = 18.2 ksi Pa= Pn/Qc = 11680 lb/1.92 = 6,083 lb Myield=My= Sx*Fy = 0.753 inA3 * 55000 psi = 41,415 in-lb Per= nA2EI/(KL)maxA2 = nA2*29500 ksi/(l.7*98.75 in)A2 = 11,674 lb (753 lb/6083 lb)+ (7367 in-lb/24799 in-lb)= 0.34 < 1.0, OK (EQ C5-3) ** For comparison, total column stress computed for load case 5 is: 27.0% ilizinqloads 872.1705 lb Axial and M= 5525 in-lb GENMARK FARADAY TYPE A Page l of l't I0/25/2016 Str~ural vonc~ts ~-fr:;} Lngineering ----U 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714 632.7330 Fax: 714.632.7763 By: ENHAO ZHANG Project: GENMARK FARADAY BEAM Configuration: TYPE A SELECTIVE RACK DETERMINE ALLOWABLE MOMENT CAPACITY A) Check compression flange for local buckling (82.1) W= C -2*t -2*r = 1.625 in -2*0.06 in -2*0.06 in = 1.385 in w/t= 23.08 !=lambda= [1.052/(k)AO.S] * (w/t) * (Fy/E)A0.5 = [J.052/(4)A0.5] * 23.08 * (55/29500)A0,5 = 0.524 < 0.673, Flange is fully effective B) check web for local buckling per section b2.3 fl(eomp)= Fy*(y3/y2)= 47.24 ksi f2(tension)= Fy*(yl/y2)= 99.00 ksi Y= f2/fl = ·2.096 k= 4 + 2*(1·Y)A3 + 2*(1·Y) = 69.54 flat depth=w= yl +y3 Eq. 82.3·5 Eq. 82.3·4 Eq. 82.1-4 Eq. 82.H = 2.260 in w/t= 37.66666667 OK !=lambda= [1.052/(k)A0.5] * (w/t) * (fl/E)A0.5 = [J.052/(69.54)A0,5] * 2.26 * (47.24/29500)A0,5 = 0.19 < 0.673 be=w= 2.260 in bl= be(3·Y) = 0.443 b2= be/2 = 1.13 in bl+b2= 1.573 in > 0.73 in, Web is fully effective Determine effect of cold working on steel yield point (Fya) per section A7.2 Fya= ('Fye+ (l·C)'Fy (EQ A7.2·1) Leorner=Le= (p/2) * (r + t/2) 0.141 in Lflange-top=Lf= 1.385 in m= 0.192*(Fu/Fy) • 0.068 = 0.1590 C= 2'Le/(Lf+2*Le) = 0.169 in (EQ A7.2-4) Be= 3.69*(Fu/Fy) · 0.819*(Fu/Fy)A2 · 1.79 = 1.427 si nee fu/Fv= 1.18 < 1.2 and r/t= 1 < 7 OK then Fye= Be * Fy/(R/tYm = 78.485 ksi (EQ A7.2·2) Thus, Fyawtop= 58.97 ksi (tension stress at top) Fya-bottom= Fya*Yeg/(depth ·Yeg) = 114.48 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lftange-bot=Lfb= Lbottom • 2*r*·2*t = 2.510 in Cbottom=Cb= 2*Le/(Lfb+2*Le) = 0.101 Fy-bottom=Fyb= Cb'Fye + (l·Cb)*Fyf = 57.37 ksi Fya= (Fya·top)*(Fyb/Fya-bottom) = 29.56 ksi Eq 82.3·2 (EQ A7.2-3) if F= 0.95 Then F*Mn=F*Fya*Sx=j 10.04 inwk 8./ Project#: Q-102516--2LV 2.75 in ~3io + T 1.625 in 2.500 in Beam= HMH 24160/2 5" Face x O 06" thk _i Ix= 0.512 in"4 Sx= 0.358 in"'-3 Yeg= 1.650 in t= 0.060 in Bend Radius=r= 0.060 in Fy=Fyv= 55.00 ksi Fu=Fuv= 65.00 ksi E= 29500 ksi top flange=b= 1.625 in bottom flange= 2.750 in Web depth= 2.:=nn ;,... L-Fy - f1(comp) 12(tens,on) yl= Yeg+r= 1.530 in y2= depth-Veg= 0.850 in y3= y2+r= 0.730 in Str~t:Jral '~~-yncEt~gineering -1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO ZHANG Project: GENMARK FARADAY BEAM Configuration: TYPE A SELECTIVE RACK RMI Section 5.2, PT II Section Beam= HMH 24160/2.5" Face x 0.06" thk lx=lb= 0.512 inA4 Sx= 0.358 in,..._ 3 t= 0.060 in Fy=Fyv= 55 ksi Fu=Fuv= 65 ksi Fya= 59.0 ksi 1. Check Bending Stress Allowable Loads Mcenter=F*Mn= W*L *W*Rm/8 E= 29500 ksi F= 150.0 L= 96 in Beam Level= 1 P=Product Load= 1,000 lb/pair D=Dead Load= 75 lb/pair W=LRFD Load Factor= 1.2*D + 1.4*P+1.4*(0.125)*P FOR DL=20/o of PL, W= 1.599 Rm= 1-[(2*F*L)/(6*E*Ib + 3*F*L)] RMI 2 • .2, item 8 1-(2*150*96 in)/[(6*29500 ksi*0.5115 inA3)+(3*150*96 in)] = 0.785 if F= 0.95 Then F*Mn=F*Fya*Sx= 20.04 in-k Thus, allowable load per beam pair=W= F'Mn*8*(# ofbeams)/(L'Rm*W) = 20.04 in-k * 8 ' 2/(96in * 0.785 * 1.599) = 2,661 lb/pair allowable load based on bending stress Mend= W'L*(l-Rm)/8 = (2661 lb/2) * 96 in* (1-0.785)/8 = 3,433 in-lb = 1,290 in-lb @ 2661 lb max allowable load @ 1000 lb imposed product load 2. Check Deflection Stress Allowable Loads Dmax= Dss*Rd Rd= 1 · (4*F'L)/(5*F'L + lO*E*lb) = 1 -(4*150*96 in)/[(5*150*96 in)+(10*29500 ksi*0.5115 inA4)] = 0.742 in if Dmax= L/180 Based on L/180 Deflection Criteria and Dss= 5*W'L A3/(384*E*lb) L/180= 5*W'L A 3*Rd/(384*E*Ib*# of beams) solving for W yields, W= 384*E*I*2/(180*5'LA 2*Rd) = 384*0.S115 inA4*2/[180*5*(96 in)A2*0.742) = 1,883 lb/pair allowable load based on deflection limits Pro;ect #: 9-102s16-2LV 2.75in t;.3io } T 1.625 ln 2.500 in 0.060 in ~ :-:tJ~U 11!!!0!!!1 O!!!l ll!!e/ll!!e)ll!!!l l!!!ll l!!!lll!!!il 1~111!!!1 I l!!!li!!!I! 1!!!1 O~lll~I I l!!eO 1!!!111~1 l;fl):::: ' . Beam Length Allowable Deflecbon= L/180 = 0.533 in Deflection at imposed Load= 0.283 in ' . Thus, based on the least capacity of item 1 and 2 above: Allowable load= 1,883 lb/pair Imposed Product Load= 1,000 lb/pair Beam Stress= 0.53 Beam at Level 1 L-~~~~~~--' _c::;+M,1.,..+,, .. ,.I ~:nine>Prinn r~~ 1 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV 3 Pin Beam to Column Connection "TYPE A SELECTIVE RACK I he beam end moments shown heretn show the result of the maximum induced fixed end monents form seismic + static loads and the code mandated minimum value of 1.5u/o(DL+PL) Mconn max= (Mseismic + Mend-fixity)*0.70*Rho = 4,956 in-lb Load at level 1 , .. A--+.:..:.'31/__l,12- ~l/2" Connector Type= 3 Pin Shear Capacity of Pin Pin Diam= 0.44 in Ashear= (0.438 in)A2 * Pi/4 = Q.1507 jnA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi* 0.15Q7inA2 = 3,315 lb Bearing Capacity of Pin tcol= O.D75 in Omega= 2.22 Fy= 55,000 psi Fu= 65,000 psi a= 2.22 Pbearing= atpna "' Fu "' diam "'teal/Omega = 2.22"' 65000 psi * 0.438 in "'0.075 in/2.22 = 2,135 lb < 3315 lb Moment Capacity of Bracket Edge Distance=E= 1.00 in Pin Spacing= 2.0 in C= Pl+P2+P3 tclip= 0.18 in = Pl+Pl *(2.5"/4.5")+Pl *(0.5''/4.5") = 1.667 * Pl Mcap= Sclip * Fbending = 0.127 jnA 3 * 0,66 * fy = 4,610 in-lb Pclip= Mcap/(1.667 * d) C*d= Mcap = 1.667 = 4610.! in-lb/(1.667 * 0.5 in) = 5,531 lb Thus, Pl= 2,135 lb Mconn-allow= [Pl *4.S"+Pl *{2.5"/4.5")*2.5"+Pl *(0.5"/4.5")*0.5"] = 2135 LB*[4.5"+{2.5"/4.5")*2.5"+ (0.5"/4.5")*0.5"] = 12,691 in~/b > Mconn max, OK GENMARK FARADAY TYPE A Page 'l of l lf- Fy= 55,000 psi Sclip= 0.127 inA3 d= E/2 = 0.50 in rho= 1.0000 10/25/2016 Str.uctural Concepts ~ ~..;j Engineering · ·--';;/ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-10251&.2LV Transverse Brace Configuration: TYPE A SELECTIVE RACK Section Pro erties Diagonal Member= Hannibal H/2xH/2x16ga Horizontal Member= Hannibal H/2xH/2xl6ga r 1.500in -, Area= 0.273 in"2 r min= 0.496 in Fy= 55,000 psi K= 1.0 Qc= 1.92 LJ}''" Area= 0.273 in" 2 r min= 0.496 in Fy= 55,000 psi K= 1.0 Frame Dimensions Diagonal Member ~ ~ 0.250in Bottom Panel Height=H= 48.0 in Frame Depth=D= 42.0 in Column Width=B= 3.0 in Clear Depth=D·B*2= 36.0 in X Brace= NO rho= 1.00 Q..1[1,/£$,.-j,~7{1r.8Jf+o:i4~r:."' 0 I Load Case 6:: (1.±f) 104:!&t'sjfj + [(0.85+0.14Sds)*B*P + [0.7*rho*E]<= 1.0, ASD Method D --1 -~--., Vtransverse= 285 lb Vb=Vtransv*0.7*rho= 285 lb * 0.7 * 1 = 2001b Ldiag= [(D·B'2)A2 + (H·6")A2JA1/2 = 55.3 in Pmax= V*(Ldiag/0) * 0.75 = 197 lb (kl/r)= (k * Ldiag)/r min = (1 x 55.3 in /0.496 in ) = 111.5 in Fe= piA2'E/(kl/r)A2 = 23,419 psi axial load on diagonal brace member Since Fe<Fy/2, Fn= Fe -r F==-==11 Pn= AREA*Fn = 0.273 inA2' 23419 psi = 6,393 lb Pallow= Pn/Q = 6393 lb /1.92 = 3,330 lb Pn/Pallow= 0.06 Horizontal brace Vb=Vtransv*0.7*rho= 200 lb (kl/r)= (k' Lhoriz)/r min = (1 x 42 in) /0.496 in = 84.7 in Since Fe>Fy/2, Fn=Fy*(l-fy/4fe) = 36,366 psi Pn/Pallow= 0.04 GENMARK FARADAY TYPE A <= 1.0 OK <= 1.0 OK Fe= piA2*E/(kl/r)A2 = 40,584psi Pn= AREA*Fn = 0.273inA 2*36366 psi = 9,928 lb Page / O of I 'f = 23,419 psi 8 +t Check End Weld Lweld= 2.5 in Fu= 65 ksi tmin= 0.060 in Typical Panel Configuration Weld Capacity= 0.75 * tmin * L * Fu/2.5 = 2,925 lb OK Fy/2= 27,500 psi Pallow= Pn/Qc = 9928 lb /1.92 = 5,171 lb 10/25/2016 Structural Concepts 7~ Engineering -·--~ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632J330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Single Row Frame Overturning Configuration: TYPE A SELECTIVE RACK Loads Critical Load case( s): 1) RMI Sec 2.2, item 7: (0.9-0.2Sds)D + (0.9-0.20Sds)*B*Papp -E*rho Vtrans=V=E=Qe= 285 lb DEAD LOAD PER UPRIGHT=D= 150 lb PRODUCT LOAD PER UPRIGHT =P= 2,000 lb Papp=P*0.67= 1,340 lb Wst LC1=Wst1=(0.7472*D + 0.7472*Papp*1)= 1,113 lb Product Load Top Level, Ptop= 1,000 lb DL/Lvl= 75 lb Seismic Ovt based on E, L(Fi*hi)= 40,889 in-lb h h /d h 3 eia1 t eot ratio= .2 in Al Fullv Loaded Rack Load case 1: Movt= L(Fi*hi)*E*rho = 40,889 in-lb Sds= 0.7640 (0.9-0.2Sds)= 0.7472 (0.9-0.2Sds)= 0.7472 B= 1.0000 rho= 1.0000 Frame Depth=Df= 42.0 in Htop-lvl=H= 134.0 in # Levels= 2 # Anchors/Base= 1 ho= 48.0 in h=H+ho/2= 158.0 in Mst= Wstl * Df/2 = 1113 lb* 42 in/2 = 23,373 in-lb Project#: Q-102516-2LV H h T SIDE ELEVATION T = (Movt-Mst)/Df = (40889 in-lb-23373 in-lb)/42 in = 4171b Net Uplift per Column I Net Seismic Uplift= 417 lb Strenath Level B) Ton Level Loaded Onlv Load case 1: 0 Vl=Vtop= Cs* Ip* Ptop >= 350 lb for H/D >6.0 Movt= [VI *h + V2 * H/2]*0.?*rno = 0.191 * 1000 lb = 22,468 in-lb = 191 lb T= (Movt-Mst)/Df Vleff= 191 lb Critical Level= 2 = (22468 in-lb -18045 in-lb)/42 in V2=VoL = Cs*Ip*D Cs*Ip= 0.1910 = 1051b Net Uplift per Column = 291b Mst= (0.7472*D + 0.7472*Ptop*l) * 42 in/2 = 18,045 in-lb I Net Seismic Uplift= 105 lb Strenath Level Anchor Check (1) 0.5" x 3.25" Embed HILTI KWIKBOLT TZ anchor(s) per base plate. Special inspection is required per ESR 1917. Pullout Capacity=Tcap= 1,250 lb L.A. City Jurisdicton? NO Shear capacity=Vcap= 1,840 lb Phi= 1 Fully Loaded: (417 lb/1250 lb)Al + (142 lb/1840 lb)Al = 0.41 Top Level Loaded: (!05 lb/1250 lb)Al + (95 lb/1840 lb)Al = 0.14 GENMARK FARADA YTYPE A Page I I of I 't Tcap*Phi= 1,250 lb Vcap*Phi= 1,840 lb <= 1.2 OK <= 1.2 OK 10/25/2016 Str.uctural Concepts ~4 Engineering ~ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV Base Plate Configuration: 1YPE A SELECTIVE RACK Section Baseplate= 8x5x3/8 Eff Width=W = 8.00 in Eff Depth=D = 5.00 in Column Width=b = 3.00 in Column Depth=dc = 3.00 in L = 2.50 in Plate Thickness=t = 0.375 in a= 3.00 in Anchor c.c. =2*a=d = 6.00 in N=# Anchor/Base= 1 Fy = 36,000 psi Downaisle Elevation Down Aisle Loads Load Case 5:: (1+0.105*Sds/D + 0.75*{(1.4+0.14Sds/*B*P + 0.75*{0.?*rho*E/<-1.0, ASD Method COLUMN DL= 75 lb Axial=P= 1.08022 * 75 lb+ 0.75 * (1.50696 * 0.7 * 1000 lb) COLUMN PL= 1,000 lb = 872 lb Base Moment= O in-lb 1 +0.105*Sds= 1.0802 1.4+0.14Sds= 1.5070 Mb= Base Moment*0.75*0.7*rho = O in-lb * 0.75*0.7*rho = o in-lb 8= 0.7000 Axial Load P = 872 lb Mbase=Mb = 0 in-lb Axial stress=fa = PIA= P/(D*W) = 22 psi Moment Stress=fb = M/S = 6*Mb/[(D*BA2] = 0.0 psi Moment Stress=fbl = fb-fb2 = 0.0 psi M3 = (1/2)*fb2*L *(2/3)*L = (1/3)*fb2*L A2 = o in-lb 5-plate = (l)(tA2)/6 = 0.023 inA3/in fb/Fb = Mtotalj[(S-plate)(Fb)l 0.11 OK Tanchor = (Mb-(PLapp*0.75*0.46)(a))/[(d)*N/2] = -1,113 lb No Tension Ml= wL A2/2= fa*L A2/2 = 68 in-lb Moment Stress=fb2 = 2 * fb * L/W = 0.0 psi M2= fbl *L A2)/2 = O in-lb Mtotal = Ml +M2+M3 = 68 in-lb/in Fb = 0.75*Fy = 27,000 psi F'p= 0.7*F'c = 1,750 psi Tallow= 1,250 lb OK OK Cross Aisle Loads CnDa1 lo.Jd,,.,.... KMI ~ z.1, ibvtJ ,, .. r1+o.J.JS,k)OL + r1+0.14Sos}PI.. 'IJ.75+8. "O.?S <~ 1.0, ,'SO Method Check uplift load on Baseplate Elf< Effe Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. Pstatic= 872 lb Movt*0.75*0.7*rho= 21,467 in-lb Frame Depth= 42.0 in P=Pstatic+Pseismic= 1,383 lb b =Column Depth= 3.00 in L =Base Plate Depth-Col Depth= 2.50 in fa= P/A = P/(D*W) = 35 psi Sbase/in = (l)(tA2)/6 = 0.023 in A 3/in fb/Fb = M/[(S-plate)(Fb)l 0.17 GENMARK FARADAYTYPE A OK Pseismic= Movt/Frame Depth = 511 lb M= wl "2/2= fa*L "2/2 = 108 in-lb/in Fbase = 0.75*Fy = 27,000 psi Page 12-all t When the base plate configuration consists of two anchor bolts located on either side f the column and a net uplift force exists, the minimum base plate thickness hall be determined based on a design bending moment in the plate equal the uplift force on one anchor times 1/2 the distance from e centerline of the anchor to the nearest edge of the rack column" l~;rh Ta i* M, I b I Ii • • • Elevation Uplift per Column= 417 lb Qty Anchor per BP= 1 NetTension per anchor=Ta= 417 lb C= 2.50 in Mu=Moment on Baseplate due to uplift:= Ta*c/2 fb Fb *0.75= 0.124 = 521 in-lb Splate= 0.117 inA3 OK 10/25/2016 Stwctural Concepts ~~ Engineering ---~ 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: Q-102516-2LV Slab on Grade Configuration: lYPE A SELECT1VE RACK a SLAB ELEVATION Baseplate Plan View Concrete Fe= 2,500 psi tslab=t= 5.0 in teff= 5.0 in phi=0= 0.6 Soil fsoil= 750 psf Movt= 30,178 in-lb Frame depth= 42.0 in 5ds= 0.764 0.2*Sds= 0.153 Base Plate Effec. Baseplate w1dth=B: 8.00 in Effec. Baseplate Depth=D= 5.00 in width=a= 3.00 in depth=b= 3.00 in 1"" 0.600 P=B/D= 1.600 F'cA0.5= 50.00 psi Column Loads DEAD LOAD=D= 75 lb per column unfactored ASD load PRODUCT LOAD=P= 1,000 lb per column unfactored ASD load Papp= 670 lb per column P-seismic=E= (Movt/Frame depth) = 718 lb per column unfactored Limit State load B= 0.7000 rho= 1.0000 Sds= 0.7640 1.2 + 0.2*Sds= 1.3528 0. 9 -0.20Sds= 0. 7472 Puncture Apunct= [(c+t)+(e+t)]*2*t = 195.Q jnA2 Fpunctl= [(4/3 + 8/(3*p)J * ). *(F'cA0.5) = 90. psi Fpunct2= 2.66 * lo * (PcAO.S) = 79.8 psi Fpunct elf= 79.8 psi Slab Bendin Pse=DL+PL+E= 1,808 lb Asoil= (Pse*l44)/(fsoil) = 347 in"2 x= (L-y)/2 = 2.0 in Fb= 5*(phi)*(fc)A0.5 = 150 .. psi GENMARK FARADAY TYPE A midway dist face of column to edge of plate=c= 5.50 in midway dist face of column to edge of plate=e= 4.00 in Load Case 1) (1.2+0.2Sds)D + (1.2+0.2Sds)*B*P+ rho*E RMI SEC 2.2 EQTN, = 1.3528 * 75 lb + 1.3528 * 0.7 * 1000 lb+ 1 ' 718 lb = 1,766 lb Load Case 2) (0.9-0.2Sds)D + (0.9-0.2Sds)*B*Papp + rho*E RMI SEC 22 EQTN 7 = 0.7472 * 75 lb+ 0.7472' 0.7 * 670 lb+ 1 * 718 lb = 1,124 lb Load Case 3) 1.2*0 + 1.4*P = 1.2*75 lb+ 1.4*1000 lb = 1,490 lb Load Case 4) 1.2*D + 1.0*P + LOE = 1,808 lb Effective Column Load=Pu= 1,808 lb per column fv/Fv= Pu/(Apunct*Fpunct) L= (Asoil)A0.5 = 18.63 in M= w*x,..,2/2 = (fsoil*xA2)/(144*2) = 10.1 in-lb Page \3 of I Lf 0.116 < 1 OK y= (c*e)"0.5 + 2*t = 14.7 in S-slab= 1 *teffA 2/6 = 4.17 in"3 fb/Fb= M/(5-slab*Fb) 0.016 < 1, OK RMI SEC 2.2 EQTN 1,2 I0/25/2016 Str~ural l,oncepts ~;j Engineering ·-.. c';J 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: ENHAO Project: GENMARK FARADAY Project#: 0-102516-2LV Configuration & Summary: TYPE B SELECT1VE RACK T 24" t 24" 144" t-- 24" + 68" .1 ' Seismic Criteria Ss=l.069, Fa=l.072 Component Column Column & Backer Beam Beam Connector Brace-Horizontal Brace-Diagonal Base Plate Anchor Slab & Soil Level 1 Load** 1 2 3 4 Per Level 1,000 lb 1,000 lb 1,000 lb 1,000 lb #BmLvls 4 Fy=SS ksi None Fy=SS ksi Fy=SS ksi Fy=SS ksi Fy=SS ksi ~=36ksi 1 oer Base Beam Spcg 68.0 in 24.0 in 24.0 in 24.0 in ** Load defined as product weight per pair of beams Notes l GENMARK FARADA YTYPE B 144" 36" l- ,r'-42" -.,.f-,t'--42'' -+ *'RACK COLUMN REAmONS ASDLOADS AXIAL DL= 150 lb AAIAL LL= 2,000 lb SEISMIC AXIAL Ps=+/-1,827 lb BASE MOMENT= 0 in-lb Frame Depth Frame Height # Diagonals Beam Length Frame Type 42 in 144.0 in 3 96in Single Row Description STRESS Hannibal IF3014-3x3x14ga P-2150 lb, M=14105 in-lb 0.48-0K None None N/A HMH 24160/2.5" Face x 0.06" thk Lu-96 in I Capacity: 1883 lb/pr 0.53-0K Lvl 1: 3 pin OK 1 Mconn=6602 in-lb I Mcap=l2691 in-lb 0.52-0K Hannibal 1-1/2xl-l/2x16ga 0.08-0K Hannibal 1-1/2xl-l/2x16ga 0.12-0K 8x5x3/8 I Fixity= 0 in-lb 0.33-0K OS' x 3.25" Embed HIL TI KWIKBOLT TZ ESR 1917 Inspection Reqd (Net Seismic Uplift=715 lb) 0.608-0K 5" thk x 2500 psi slab on grade. 750 psf Soil Bearing Pressure Brace 36.0 in 48.0 in 48.0 in Total: I Story Force I Transv 931b 1261b 1591b 1921b 5691b Story Force Long it. 71 lb 961b 121 lb 1461b 4341b Page/ 4-of llf Column Axial 2,150 lb 1,613 lb 1,075 lb 5381b I Column I Moment 14,105 "# 2,179 "# 1,603 "# 877 "# Conn. Moment 6,602 "# 2,226 "# 1,771 "# 1,210 "# 0.22-0K Beam Connector 3 pin OK 3 pin OK 3 pin OK 3 pin OK 10/25/2016 SAN DIEGO REGIONAL OFFICE USE ONLY HAZARDOUS MATERIALS RECORD ID# PLAN CHECK# QUESTIONNAIRE BP DATE (,..~/IIWJ:. Business Contact ~AJW\ Nil\/\ C.ltw\-Telephone# l~~-tl~-1i\i Project Address d-':J~ trvt\ I',~ City W.L~ tA°t, State(/\ Zip Code ~~ll APN# ~i;s. ~ I~ Mailing Address~\} r~~ A--Jt I'\ I City WU.l"1:1 State\J\.-Zip Code ~~q Plan File# ~il Project Contact 'fJ.. J/\\J I ~Vi.A,~ _ M_ Applicant ->~I . Vt r,,Js.P-~ ail &.J AA'/ ""·"'"''"L N Telephone# The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZAR OU MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: not re uired for o ects within the Cit of San Diego): nd1cate by c1rc mg t e item, w et er your business w1 use, process, or store any o the following haza ous materials. l any o the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 2, Compressed Gases 5. Organic Peroxides 9. Water Reactives 6. Oxidizers 10. Cryogenics 13. Corrosives 2{: Other Health Hazards \J None of These. 3. Flammable/Combustible Liquids 7, Pyrophorics 11. Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART 11: SA Di GO COUNTY E AR ME T OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION HMO: if the answer to any of the questions is yes, applicant must contact the aunty of San Diego Hazardous Materials 0·1vision, 5500 overland Avenue. Suite 11 o, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CalARP Exempt I 1. 2. 3. 4. 5. 6. 7. 8. YES NO D 121' D l2r D Q- D D D D D (for new construction or remodeling projects) Is your business listed on the reverse side of this form? {check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or ·handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances {CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or reater than 1,320 al Ions? California's Above round Petroleum Stora e Act . Date Initials D CalARP Required I Date Initials 0 CalARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT [APCD): Any YES' answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcounty.ca.gov (858) 586-2650). [*No stamp required if Q1 Yes and Q3 Yes MQ Q4-Q6 No}. The following questions are intended to identify the majority of air pollution Issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except -those with more than one building+ on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use: deliberate burns: residences forming part of a larger project. !~Excludes garages & small outbuildings.] 1. 2. 3. 4. 5. 6. YES NO D B Will the project disturb 160 square feet or more of existing building materials? D O-Wi11 any load supporting structural members be removed? Notification may be required 1 O working days prior to commencing demolition. (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? D D D D D D (ANSWER ONLY JF QUESTION 315 YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. ~ Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCO factsheet (www.sdapcd.org/info/facts/permits.pdf) for typical equipment requiring an APCD permit. D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bounda Briefly describe business activities: N'J\;l'<-.,S: 1\-i:S" w!:>-QI' IIW>~ \'.W l~ Briefly describe proposed project 1 .r ,, Au. du I'( 1- I declare Uf~er 12enalty ofJJerjury that to the best of my knowledge and belief t e resp ses made herein are true and correct. t-' t'l,..l.f \_,~ 1q :):i_ I f} I d1 ~ Name of Owner or Authorized Agent Date FOR OFFICAL use ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _______________________________ _ BY DATE· / / EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASED FOR BUtl..OlNG PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO* APCO COUNTY-HMO APCD COUNTY-HMO APCD ·A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may sttll apply. HM-9171 108/15\ Countv of San Dieoo -DEH -Hazardous Materials Division LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE D Battery Manufacturing/Recycling D Boat Yard D Car Wash D Dealership Maintenance/Painting D Machine Shop D Painting D Radiator Shop D Rental Yard Equipment D Repair/Preventive Maintenance D Spray Booth D Transportation Services 0 Wrecking/Recycling CHEMICAL HANDLING D Agricultural supplier/distributor 0 Chemical Manufacturer D Chemical Supplier/Distributor D Coatings/Adhesive D Compressed Gas Supplier/Distributor D Dry Cleaning D Fiberglass/Resin Application D Gas Station D Industrial Laundry D Laboratory D Laboratory Supplier/Distributor D Oil and Fuel Bulk Supply O Pesticide Operator/Distributor CHEMICAL HANDLING D Photographic Processing 0 Pool Supplies/Maintenance D Printing/Blue Printing D Road Coatings D Swimming Pool D Toxic Gas Handler D Toxic Gas Manufacturer METAL WORKING 0 Anodizing D Chemical Milling/Etching 0 Finish-Coating/Painting D Flame Spraying D Foundry D Machine Shop-Drilling/Lathes/Mills D Metal Plating D Metal Prepping/Chemical Coating 0 Precious Metal Recovery D Sand Blasting/Grinding D Steel Fabricator 0 Wrought Iron Manufacturing AEROSPACE D Aerospace Industry D Aircraft Maintenance D Aircraft Manufacturing OTHERS AND MISCELLANEOUS D Asphalt Plant D Biotechnology/Research D Chiropractic Office D Co-Generation Plant D Dental Clinic/Office 0 Dialysis Center D Emergency Generator 0 Frozen Food Processing Facility D Hazardous Waste Hauler 0 Hospital/Convalescent Home D Laboratory/Biological Lab 0 Medical Clinic/Office D Nitrous Oxide (NOx) Control System D Pharmaceuticals D Public Utility D Refrigeration System D Rock Quarry D Ship Repair/Construction D Telecommunications Cell Site 0 Veterinary Clinic/Hospital D Wood/Furniture Manufacturing/Refinishing ELECTRONICS D Electronic Assembly/Sub-Assembly 0 Electronic Components Manufacturing 0 Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INClUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMO) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47 -Organic Gas Sterilizers 32 -Acid Chemical Milling 33 -Can & Coil Manufacturing 44 -Evaporators, Dryers & Stills Processing Organic Materials 24 -Dry Chemical Mixing & Detergent Spray Towers 35 -Bulk Dry Chemicals Storage 55 -Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27 -Coating & Painting 37 -Plasma Arc & Ceramic Deposition Spray Booths 38 -Paint, Stain & Ink Mfg 27 -Printing 27 -Polyester Resin/Fiberglass Operations METALS 18 -Metal Melting Devices 19 -Oil Quenching & Salt Baths 32 -Hot Dip Galvanizing 39 -Precious Metals Refining ORGANIC COMPOUND MARKETING· (GASOLINE. ETC) 25 -Gasoline & Alcohol Bulk Plants & Terminals 25 -Intermediate Refuelers 26 -Gasoline & Alcohol Fuel Dispensing COMBUSTION 34 -Piston Internal -Combustion Engines 13 -Boilers & Heaters (1 million BTU/hr or larger) 14 -Incinerators & Crematories 15 -Burn Out Ovens 16 -Core Ovens 20-Gas Turbines, and Turbine Test Cells & Stands 48 -Landfill and/or Digester Gas Flares ELECTRONICS 29 -Automated Soldering 42 -Electronic Component Mfg FOOD 12-Fish Canneries 12 -Smoke Houses 50 -Coffee Roasters 35 -Bulk Flour & Powered Sugar Storage SOLVENT USE 28 -Vapor & Cold Degreasing 30 -Solvent & Extract Driers 31 -Dry Cleaning ROCK AND MINERAL 04 -Hot Asphalt Batch Plants 05 -Rock Drills 06 -Screening Operations 07 -Sand Rock & Aggregate Plants 08 -Concrete Batch, CTB, Concrete Mixers, Mixers &Silos 10 -Brick Manufacturing OTHER 01 -Abrasive Blasting Equipment 03 -Asphalt Roofing Kettles & Tankers 46 -Reverse Osmosis Membrane Mfg 51 -Aqueous Waste Neutralization 11 -Tire Buffers 17 -Brake Debonders 23 -Bulk Grain & Ory Chemical Transfer & Storage 45 -Rubber Mixers 21 -Waste Disposal & Reclamation Units 36 -Grinding Booths & Rooms 40 -Asphalt Pavement Heaters 43 -Ceramic Slip Casting 41 -Perlita Processing 40 -Cooling Towers-Registration Only 91 -Fumigation Operations 56 -VWITP {1 million gal/day.or larger) & Pump Station NOTE; OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (08/15) Countv of San Dieao -DEH -Hazardous Materials Division ·-····--·----------------- December 29, 2017 CARLSBAD 2210 LLC 8100 MAPLEWOOD AVE #220 GREENWOOD VILLAGE, CO 80111 APPLICATION DATE: PLAN CHECK#: ADDRESS: EXPIRATION DATE: PERMIT TYPE: DESCRIPTION: 12/22/2016 CBC2016-0090 2210 FARADAY AVE 12/22/2017 COMMERCIAL GEN MARK: HIGH-PILE STORAGE RACKS APRX 1,850 SF AREA ( City of Carlsbad You applied to have your plans checked on the date noted above. To date, the related building permit has not been obtained and the original plan review application will expire on the date noted above. This courtesy notice is sent to advise you of the following provisions of the City's codes regarding expiration: 18.04.035 -Section 107.4 amended-Expiration of pion review. Section 107.4 of the California Building Code is amended to read: Applications for which no permit is issued within one year Jo/lowing the date of application sha/1 expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. 90 day extensions of the plan review period may be granted by the Building Official after review of a letter of explanation provided to him by the property owner. An extension of time granted by the Building Official does not. by right. apply to any related Discretionary Permit under review. Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed. In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department: __ Project Abandoned - I will pick up the plans within 10 days __ Project Abandoned -Plans may be destroyed __ I would like to Apply for a 90 Day Extenstion. My letter of explanation and signed request is included. NOTE: Your request will not be considered if no letter is included. If you have any questions, please contact the Building Division at (760) 602-2719. Building Division Community & Economic Development Building Division I 1635 Faraday Avenue Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov December 29, 2017 RAYMOND HANDLING SOLUTIONS C/0 JAVIER CAMBERO 9939 NORWALK BLVD SANTA FE SPRINGS, CA 90670 APPLICATION DATE: PLAN CHECK#: ADDRESS: EXPIRATION DATE: PERMIT TYPE: DESCRIPTION: 12/22/2016 CBC2016-0090 2210 FARADAY AVE 12/22/2017 COMMERCIAL GEN MARK: HIGH-PILE STORAGE RACKS APRX 1,BSO SF AREA ('city of Carlsbad You applied to have your plans checked on the date noted above. To date, the related building permit has not been obtained and the original plan review application will expire on the date noted above. This courtesy notice is sent to advise you of the following provisions of the City's codes regarding expiration: 18.04.035 -Section 107.4 amended-Expiration of plan review. Section 107.4 of the California Building Code is amended to read: Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. 90 day extensions of the plan review period may be granted by the Building Official after review of a letter of explanation provided to him by the property owner. An extension of time granted by the Building Official does not. by right. apply ta any related Discretianary Permit under review. Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed. In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department: __ Project Abandoned - I will pick up the plans within 10 days __ Project Abandoned -Plans may be destroyed __ I would like to Apply for a 90 Day Extenstion. My letter of explanation and signed request is included. NOTE: Your request will not be considered if no letter is included. If you have any questions, please contact the Building Division at (760) 602-2719. Building Division Community & Economic Development Building Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov