HomeMy WebLinkAbout2216 CAMEO RD; ; CBR2019-1215; PermitResidential Permit
Print Date: 12/16/2019
Job Address:
Permit Type:
2216 Cameo Rd
BLDG-Residential
1670803000
$35,812.70
Work Class: Alteration
Parcel No: Lot#:
Valuation: Reference #:
Occupancy Group: Construction Type:
# Dwelling Units: Bathrooms:
Bedrooms: Orig. Plan Check#:
Plan Check#:
Project Title:
Description: SCHREADER: 770 SF REMODEL
Applicant:
RUBEN FABIAN
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
JOSHUA SCHREADER
2216 Cameo Rd
CALRSBAD,CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $647.54 Total Payments To Date: $647.54
(city of
Carlsbad
Permit No: CBR2019-1215
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Closed -Finaled
05/15/2019
06/28/2019
Inspection: 12/16/2019 11:0l:32A
Balance Due: $0.00
$316.40
$221.48
$41.00
$62,00
$2.00
$4.66
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
Ccicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check CSR~0)9-1a)S
Est. Value ~~. i1a:ID
PC Deposit ---------
Date __ 5....,/u../ 5~/ /'--'9'---
Job Address Z.. 2-) G:z kAHl=-0 '2-:I2 Suite: ____ APN: \"1-OAo-2,0,00
CT/Project#:. _________ Lot#: Z ~ Fire Sprinklers: yes/@ Air Conditioning: i§'j! no
BRIEF DESCRIPTION OF WORK: \l'\t-a-i'clYL: {4yru)~ A:\& Srl:eJ:.ioi:t-sb,~s. :l:h .... SqJU.,.
nc '-7'UC1,'o&: ,\JJo (Lio; bcl Ne;-
0 Addition/New: _____ Living SF, ___ Deck SF, ____ Patio SF, ___ Garage SF
Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __
0 Remodel: 71-0 SF of affected area Is the area a conversion or change of use ? Yes/ No
0 Pool/Spa: ____ SF Additional Gas or Electrical Features? -------------
□ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
D Reroof: --------------------------------------
□ Plumbing/Mechanical/Electrical Only: ________________________ _
D Other: __________________________________ _
APPLICANT (PRIMARY CONTACT) PROPERTY OWNER
Name: ~~~~~
Address: 0 · ~ P:?
City: ~01(\j~ State: CA Zip: ,,qoz_
Phone: t~ ~t-tl ~
Email: ( =Y\ t"tl J = f) e,{
Name: c)O't>I-\V~=~C,~-ADEB-
Address: Z.'Z\!o ~1".() .&.:c.-
City: GA:tl,Se,At> State: CA-Zip: 'f'2..o II
Phone: ___________________ _
Email: ____________________ _
CONTRACTOR BUSINESS
Name: ___________________ _
Address: __________________ _
City: ________ State: __ ~Zip: ______ _
Phone:--' .... --'---'-,...."--..:....,,_,_...,. ________ _ Phone: ___________________ _
Email: -~;,.J:l..ic:=..i.:.<-1..Jol'µJJ.J<.!..u.<"'------Email: --------------------St ate License: ______ Bus. License: ______ _
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
□ I have and will maintain a certificate of consent to self~insure for workers' compensation provided by Section 3700 of the labor Code, for the performance of the
work which this permit is issued.
□ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _
Policy No. ______________ Expiration Date: _________ _
□ Certificate of Exemption: r certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
Interest and attorney's fees.
CONTRACTOR SIGNATURE: _________________ □AGENT DATE: _____ _
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. lf, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
_I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed
pursuant to the Contractor's License Law).
□ I am exempt under Section ________ Business and Professions Code for this reason:
1. I personally plan to provide the major tabor and materials for construction of the proposed property improvement. □ Yes □ No
2. l (have/ have not) signed an application for a building permlt for the proposed work.
3. I have contracted with the following person {firm) to provide the proposed construction {include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work {in dude name/ address/ phone/
contractors' license number):
5. I wiJJ provide some of the work, but I have contra following persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: DATE: _s--+/ ....... 1 s=......,}ri--L f--
CONSTRUCTION LENDING AGEN
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
lender's Name: _____________________ _ Lender's Address: _____________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANV OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE Of EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
1 hereby authorize representative of the City of carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARlSBADAGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit ts not commenced within 180 days from the dat ch permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 days (Sect· 106.4.4 'form Building Code).
APPLICANT SIGNATURE:
1635 Faraday Ave Carlsbad, CA 92008
B-1
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of 2
Email: Building@carlsbadca.gov
Rev. 06/18
· . ' PERMIT INSPECTION HISTORY REPORT (CBR2019-1215) • , r~& C{
Permit Type: BLDG-Residential Application Date: 05/15/2019 Owner: JOSHUA SCHREADER
Work Class· Alteration Issue Date: 06/28/2019 Subdivision: CHESTNUT HEIGHTS
Status: Closed -Finaled Expiration Date: 06/08/2020 Address: 2216 Cameo Rd
IVR Number: 19113 Carlsbad, CA 92008-2758
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date -··-------
Checkllst Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
09/26/2019 09/26/2019 BLDG-17 Interior 105358-2019 Passed Paul York Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/09/2019 12/09/2019 BLDG-Final 113069-2019 Failed Paul Burnette Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
12/16/2019 12/16/2019 BLDG-Final 113854-2019 Passed Paul Burnette Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
December 16, 2019 Page 2 of:
' '
· PERMIT INSPECTION HISTORY. REPORT (CBR2019-1215)
Permit Type: BLDG-Residential Application Date: 05/15/2019 Owner: JOSHUA SCHREADER
Work Class: Alteration Issue Date: 06/28/2019 Subdivision: CHESTNUT HEIGHTS
Status: Closed -Finaled Expiratio.n Date: 06/08/2020 Address: 2216 Cameo Rd
IVR Number: 19113
Carlsbad, CA 92008-2758
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
08/16/2019 08/16/2019 BLDG-11 101073-2019 Passed Paul York Complete
Foundation/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-21 101074-2019 Passed Paul York Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/22/2019 08/22/2019 BLDG-13 Shear 101684-2019 Failed Chris Renfro Reinspection Complete
Panels/HD (ok lo
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need special inspection report on 4" or less No
shear edge nailing. Need A35 clips every
16 inches on center per plans
08/23/2019 08/23/2019 BLDG-13 Shear 101825-2019 Cancelled Paul York Re inspection Complete
Panels/HD (ok lo
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need special inspection report on 4" or less No
shear edge nailing. Need A35 clips every
16 inches on center per plans
08/26/2019 08/26/2019 BLDG-13 Shear 102018-2019 Cancelled Paul York Reinspection Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need special inspection report on 4" or less No
shear edge nailing. Need A35 clips every
16 inches on center per plans
08/27/2019 08/27/2019 BLDG-13 Shear 102051-2019 Partial Pass Paul Burnette Reinspection Incomplete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need special inspection report on 4" or less No
shear edge nailing. Need A35 clips every
16 inches on center per plans
09/17/2019 09/17/2019 BLDG-84 Rough 104302-2019 Failed Paul York Reinspection Complete
Combo(14,24,34,44)
. ··-···-·-···--·--------------------------------------------December 16, 2019 Page 1 of 2
ALLISON INSPECTION SERVICE, INC.
a DAILY REPORT
FINAL REPORT DAY DATE
TYPE OF INSPECTION: einforced Concrete D Reinforced Masonry D Structural Steel/Welding
D Other:
D Shotcrete
(One Inspection per Report) □ Pre-Stressed Concrete D Fireproofing
. / Project No File No: ,,,, .J/ ~.,/ t't'
Architect
Contractor:
DESCRIPTIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION
ABOUT-AMOUNTS OF MATERIAL Pl.ACED OR WORK PERFORMED; NUMBER, TYPE, & IDENTIFICATION NUMBERS OF TEST SAMPLES
TIME ON
SITE
)Jao
TIME OFF
SITE
REG.
HOURS
O.T.
HOURS
#OFTEST
SPECIMENS
THE WORK D was D was not inspected in accordance
with the (DSA/City) approved documents.
THE WORK INSPECTED O met O did not meet
the requirements of the_ (DSA/City) approved
documents.
Jim Allison
Name of Registered Inspector (Print)
:/4 Signature of Registered Inspector
C "dr €:d~ 84'9S,t:}
Weather Registration Number
AWS00080371/849
JoeSITE CONTACTISASKB>TOSIGN TOVFRF'f lNSPEC110NHOURSONL Y. lllECONTENTOF
TIISREPORT A>EFEEQiARGESAREntERESPONSIII.JTVOFOTHERS.
Signature:~
Owner-Authorized Job Site Contact
\
Structural Inspections LLC
*SPECIAf:-INSPECTION SERVICES*
P.O. Box 2415 El Cajon, CA 92021
Cell: (619) 770-9559 • Fax (619) 588-5955
Inspection Report
3c. ~ ' 0\ e r, ~es Project Name: .er Page:
Project Address: 2-'llb C c,Lt>ie'> ,t J Permit#: L
Architect: I \)evtt ♦ oi,.o ,. .... , l File#:
Engineer: r{Jc..,\I ~ h s I IA ' C:-,... ,, ~ DSA#:
Rt:>1." r (Y, ""';J, ✓
Contractor: ..,. Other:
INSPECTION MATERIAL SAMPLING ' QTY MATERIAL DESCRIPTION
--Structural Steel --H.S. Bolts --H.S. Bolts
--Masonry --Prisms --Cone.PSI
--Concrete --Mortar/Grout --Grout PSI
--Fireproofing --Cone. Cylinders --Mortar PSI
--Epoxy --Fireproof --Steel ,,. Other: ~,<' r l Other: Elect./Wire ------
--Other: --Other: --Fireproof
--Other: --Other: --Other:
--Other: --Other: --Other:
1 v1~ Jr 1-eJ t-( (7 S'S o I ~ t-St (t ,.AK (,...,~.;_f_ t.._lL1~
of I Report#:
C rt ' J/ '7 ,.
INSPECTION CHECKLIST
--Plans/Specs
--Clearances
Positions --
Sizes --
--Laps
Consolidation --__ Torque Ft. Lbs:
Other: --
Other: --
I
<:t). Lf/rZ Vl<>tt{'l<j YR Ar! f' 3L O( (J ( It I ~ ,.J( '1 r. iA tt a
1.1 \\ \ '...., ,,,,/ I uv if' r:' \\ n 1 (' I • r JVl /11 I H t" ,.,,. " 1,
11 rr,tJ I' f n [At.., r
CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans. specifications and applicable sections
of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control.
I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to
comply with the approved plans, specifications, and applicable sections of the governing building laws.
Inspector: MARIO BATTAGLIA Cert: 350 -----.,,, f j....f.
I f
I ) / 'I,.\ 1 ) t-. Signature Date
·:.'_··,·n···s··p··.··o····a···c·e···:·····--r-;r··r·;r-··-..1·/,t c .. _ .. ··········· ...... . ..
r····· .................... '; /. .. ':: .. ~/ I ' . . ... \ .Day.} :
t Time Start: " ~--·· ........................... ••· ...... .',,... ..... ....... ... . •··' .... .
..: (?ar,.2:. . ..... l.Day 4:. ..;P~r.5..= ........ , .... .
j ---......................................................................... :
i.!.i'.11.~ .s~~.r.=.... . ...... -..... •····•· •··· ........................... .! ............................................. •· .. .i
ProJ•ct Superintendent
Structural Inspections LLC
*SPEC/AI,, INSPECTION SERVICES*
P.O. Box 2415 EI Cajon, CA 92021
Cell: (619) 770-9559 • Fax (619) 588-5955
Inspection Report
Project Name: _________________________ _ Page: ___ / __ of ____ Report#:. ______ _
Project Address: ________________________ _ Permit#: _________________ _
File#: __________________ _
DSA #: ________________ _
Contractor: __________________________ _ Other: __________________ _
INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST
--Structural Steel --H.S. Bolts --H.S. Bolts --Plans/Specs
--Masonry --Prisms --Cone.PSI --Clearances
--Concrete --Mortar/Grout --Grout PSI --Positions
--Fireproofing --Cone. Cylinders --Mortar PSI --Sizes
--Epoxy --Fireproof --Steel --Laps
--Other: --Other: --Elect./Wire --Consolidation
--Other: --Other: --Fireproof --Torque Ft. Lbs:
--Other: --Other: --Other: --Ocher:
Other: Other: Other: Other: --------
l ti, tl -t
CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections
of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control.
I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to
comply with the approved plans, specifications, and applicable sections of the governing building laws.
Inspector: MARIO BATTAGLIA Cert: '-------350 1
Signature Date
/.1.?..SP.:P~.ti:.: ........ -..... ··•··· . ··-
; Time Start
t Time Stop:
: ...................... ..
···---····-········. .. . . . .. . . ,. .....•..... ·· .. .... . ...... ... ········,···.···· .. •··········· .. ···.1,.··D····a·.•y· .s ............... , ............ ··•··· ..... .
Day .. I: ....... ·' ...... . ......... ·;· Dar .. 2: ..... ... . . ... . . ... . P.~Y.. ~: ........ .L. ................. · ll:)~Y 4:.
.. ,,., •· ---• --••••• .... •••• ••••••••••••••·• .... •••••••"••• 00 •••• .. 0 OH•O•••••••••OO "'' •••••• ••••••••••••••••••••O•O••·••H •••••••·•••••;•••••••·••-••• ••·•••••••••• .. •••••••••••••••• .. •••)••••••••••••••••••••• .... •••• .. •••••••• ••• HH~•}
····••·•• ·····-••·••·i........................................ • •. ; ..... Lz·Ji·{
Approved By:_,..-_r/-:;-'/ __ £_~~•-'-~~~--~--------J I Project Superintendent
1 I
✓• EsG1I
A S.A.FEbu1lfCompany
DATE: June 18, 2019
JURISDICTION: Carlsbad
□~LICANT
jYJURIS.
PLAN CHECK#.: CBR2019-1215
PROJECT ADDRESS: 2216 Cameo Rd
SET: II
PROJECT NAME: Interior remodel to Schraeder Residence
□
□
□
□
□
[SJ
□
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applica1t t at the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
0 REMARKS:
By: Abe Doliente
EsGil
6/10/19
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: May 26, 2019
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2019-1215
PROJECT ADDRESS: 2216 Cameo Rd
✓• EsG1I
A SAFEbuilrCompany
SET: I
PROJECT NAME: Interior remodel to Schraeder Residence
□ APPLICANT
Jl{JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Ruben Fabian
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Ruben Fabian Telephone#: 619-666-8344
Date contacted: SI -Z.. & (by: rvl) Email: ruben@raydev.net
(Mail j TelephoneJ Fax In Person
0 REMARKS: vtv\
By: Abe Doliente
EsGil
Enclosures:
5/20/19
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2019-1215
May 26, 2019
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2019-1215
PROJECT ADDRESS: 2216 Cameo Rd
JURISDICTION: Carlsbad
FLOOR AREA: Interior Remodel -770 SF STORIES: 2
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: May 26, 2019
FOREWORD (PLEASE READ):
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 5/20/19
PLAN REVIEWER: Abe Doliente
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list {or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBR2019-1215
May 26, 2019
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and
Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
PLANS
1. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code). Signatures on the final
sets of plans will be field verified before they are approved.
2. Plans shall have the structural portions signed and sealed by the California state
licensed engineer or architect responsible for their preparation, along with
structural calculations. (California Business and Professions Code). Signatures
on the final sets of plans will be verified before they are approved.
ELECTRICAL
3. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
4. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
Carlsbad CBR2019-1215
May 26, 2019
5. Show on the plans that countertop receptacle outlets comply with CEC Article
210.52(C): In kitchens a receptacle outlet shall be installed at each counter
space 12 inches or wider; Receptacles shall be installed so that no point along
the wall line is more than 24 inches; Island and peninsular countertops 12 inches
by 24" long (or greater) shall have at least one receptacle. (Counter top spaces
separated by range tops, refrigerators, or sinks shall be considered as separate
counter top spaces).
6. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be
either:
a) A 20 ampere circuit dedicated to each bathroom, or
b) At least one 20 ampere circuit supplying only bathroom receptacle outlets.
7. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom.
CEC 210.52(D).
PLUMBING
8. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
ENERGY CONSERVATION
9. When replacing or modifying the mechanical system: If applicable.
o If more than 40' of new ductwork is installed in unconditioned space, HERS
inspection is required for both existing and new duct sealing.
o Replacement of mechanical equipment (air handler, condensing unit of an air
conditioner or heat pump, cooling or heating coil, or the furnace heat
exchanger) requires HERS inspection.
o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, it
is not required at initial plan submittal.
MISCELLANEOUS
10. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
11. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Carlsbad CBR2019-1215
May 26, 2019
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
12. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Abe Doliente at EsGil. Thank you.
Carlsbad CBR2019-1215
May 26, 2019
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Abe Doliente
BUILDING ADDRESS: 2216 Cameo Rd
BUILDING OCCUPANCY: R3/U
BUILDING
PORTION
Remodel
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
1997 UBC Buildin Permit Fee g
1997 USC Plan Check Fee
Type of Review:
□ Repetitive Fee i• Repeats
Comments:
0
AREA Valuation
(Sq.Ft.) Muliplier
770 46.51
By Ordinance
~ ...
□ Other
0 Hourly
EsGIIFee
PLAN CHECK#.: CBR2019-1215
DATE: May 26, 2019
Reg. VALUE ($)
Mod.
35,813
35,813
□ Structural Only
1------ll Hr. @ * $193.301
Sheet 1 of 1
Ccityof
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. Unless none of the requirements apply, the completed checklist must be
included in the building permit application. It may be necessary to supplement the completed checklist with
supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance
requirements. For example, projects that propose or require a performance approach to comply with energy-
related measures will need to attach to this checklist separate calculations and documentation as specified by
the ordinances .
...i If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required
by ordinance, an explanation must be provided to the satisfaction of the Building Official.
...i Details on CAP ordinance requirements are available on the city's website.
Project Name/Building
Permit No.:
Property Address/APN:
Applicant Name/Co.:
Applicant Address:
Contact Phone:
BP No.:
\G,3-08O--00-00
Contact Email:
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Contact Phone:
Contact Email:
Applicant Signature: __ ,,_~-----------Date: rf I') /If
B-50 Page 1 of J Revised 04/19
---------·---
City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For residential alterations and additi; to existi~ f tdin~/ £On tact the building counter for the building permit valuation.
Building Permit Valuation (BPV) $ 35 l't, • -yo
D New construction 1A
it(' Alterations: ~xempt
D BPV" $60,000
D Electrical service panel upgrade
, 1A
1A
1-2 family dwellings and townhouses with attached garages
only
D BPV ;e $200,000 1A
Multi-family dwellings only where interior finishes are removed
and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
0 Nonresfdenlial
. .
D New construction 1B and 2
D Alterations 2
1. Electric Veblcte Charging
A. 0 Residential New construction and major alterations (or electric panel upgrade)*
Please refer to Carlsbad Ordinance CS-349 when completing this section.
D One and two-family residential dwelling or townhouse with attached garage:
D One EVSE ready parking space required D Exception :
□ Multi-family residential· D Exception ·
Total Parking Spaces EVSESpaces
Proposed Caoable Ready Installed
Calculations: Total EVSE spaces = .10 x Total parking (rounded up to nearest whole number)
EVSE Installed =Total EVSE Spaces x .50 (rounded upto nearest whole number)
EVSE other= Total EVSE spaces -EVSE Installed
(EVSE other may be "Capable," "Ready" or "Installed.")
Total
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~$60,000 or
include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation
~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed.
8. 0 Nonresidential new construction (includes hotels/motels) D Exception ·
Total Parking Spaces EVSE Soaces
Proposed Capable Readv Installed Total
Calculation· Refer to the table below·
Total Number of Parking Spaces provided Number of reQuired EV Spaces Number of reouired EVSE Installed Spaces
D 0-9 1 1
D 10-25 2 1
D 26-50 4 2
D 51-75 6 3
D 76-100 9 5
D 101-150 12 6
D 151-200 17 9
D 201 and over 1 0 percent of total 50 oercent of Reouired EV Snaces
Updated 4/12/2019 2
City of Carlsbad Climate Action Plan Consistency Checklist
2. 0 Transportation Demand Management (TOM)
A. List each proposed nonresidential use and gross floor area (GFA) allocated to each use.
B. Employee ADT/1,000 square feet is se~cted from the table below.
Use GFA Employee ADT for first Employee ADT for each
1,000 S.F. subsequent 1,000 S.F.
Total
If total employee ADT is greater than or equal to 110 employee ADT, a TDM plan is required.
TOM plan required: Yes □ No □
Updated 4/12/2019
ADT for first Emp ADTI
Use 1,000 s.f. 1000 s.f.1
Office ( all), 20
Restaurant 11
Retail, 8
Industrial 4
Manufacturing 4
Warehousina 4
, Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 1 O'" Edition
20
11
4.5
3.5
3
1
, For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to
calculate employee ADT
, Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. /8,334 sf/ 1,000 x 4.5) + 8 = 46 Emnlovee ADT
Total Employee ADT
3