HomeMy WebLinkAbout2226 CAMEO RD; ; CB162311; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-02-2016 Residential Permit Permit No: CB162311
Job Address:
Building Inspection Request Line (760) 602-2725
2226 CAMEO RD CBAD
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
RESDNTL
1670802900
$97,966.00
0
0
Sub Type: RAD
Lot#: 0
Constuction Type: 5B
Reference #:
Structure Type:
Bathrooms: 0
Orig PC#:
Status: ISSUED
Applied: 06/14/2016
Entered By: JMA
Plan Approved: 08/02/2016
Issued: 08/02/2016
Inspect Area:
Plan Check #:
Project Title: TROSTRUD: 575 SF MASTER STE.
ADDITION// 104 SF ROOF DECK
Applicant:
TROSTRUD FAMILY TRUST 07-28-92
2226 CAMEO RD
CARLSBAD CA 92008
760-707-3726
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
$618.20
$0.00
$432.74
$0.00
$0.00
$12.74
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$4.00
$163.00
Owner:
TROSTRUD FAMILY TRUST 07-28-92
2226 CAMEO RD
CARLSBAD CA 92008
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
Total Fees: Total Payments to Date: $1,432.51 Balance Due:
Inspector:
FINAL APPROVAL
Date: £ I~ • I 7 Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$104.00
$46.00
$51.83
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1,432.51
$0.00
NCITTCE: Fl ease take l\!011CE that awrovaJ of your project includes tre "lrrposition" ci fees, dedications, reservations, or other exactia,s hereafter mlledively
referred to as "fees/exactions." You have 00 days from the date this pemit was isslEd to protest ini:ositicn of these fees/exactions. If you protest them, you rrust
fcJlo,vthe protest procedures set forth in GJvernrrent Cede Section OOJ20(a), ard file the protest and any other reqlired information IAith the aty ~r fcr
p-ocessing in accordance Wth Carlsbad M.Jnidpal Cooe Section 3.32.030. Failure to tirre!y follcm trat procedure will oor any subsequent legal action to attad<,
review, set aside, void, or annul their irrpJSition.
You are hereby FURTI-IER NOTIFIED mt your right to p-otest the specified fees/exactions COES NOT APPLY to water ard S'l'M€r connedjon fees and capacity
changes, nx plannirg, zoning, gradirg or other sinilar application l)'IJC6SSirg or service fees in mnnedion W:th this ptject.. NOR. COES IT .APPLY to any
fees'exa::tions of Wlich have viousl been iven a I\QTICE sinila' to this or as to Wlich the statute of !irritations has ·ousl othervvise 'red.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING D ENGINEERING 0BUILD1NG DFIRE 0HEALTH D HAZMATIAPCO
( City of Building Permit Application Plan Check No.CB J (o .. '2 ::,,11
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value fl °12 g-it. Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov
Date (,,/1 <I/ 11-JswPPP www.carlsbadca.gov
JOB ADDRESS SUITE#/SPACE#/UNIT#
IAPN 167 2226 Cameo Road -080 -290 -0
CT/PROJECT# ILOT# I PHASE# I# OF UNITS I# BEDROOMS #BATHROOMS I TENANT BUSINESS NAME I CONSTR, TYPE I Ot;C. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
The proposed project would add a master suite on the ground level of an existing single family residence.
rD'f~ ~ofd.u4.--t:r :;zs-5,~.
EXISTING USE I PROPOSED USE I GARAG~ {SF) PATIOS (SF) I DECKS (SF) FIREPLACE 1 I AIR CONDITIONING I FIRE SPRINKLERS SFR SFR 1/100 1/104 YESO' NoG:J YESl:!::)No[:::J YEs[:jNol:!::J
APPLICANT NAME Michael Trostrud (Son) PROPERTY OWNER NAME Arville or Beverlee T rostrud Prtnaru Contact
ADDRESS ADDRESS 2226 Cameo Road 2226 Cameo Road
CITY STATE ZIP CITY STATE ZIP Carlsbad CA 92008 Carlsbad CA 92008
PHONE IFAX PHONE IFAX 7607073726 7607294011
EMAIL EMAIL m.trostrud@hotmail.com trostrud@holmail.com
DESIGN PROFESSIONAL Michael Trostrud CONTRACTOR BUS. NAME Owner Builder
ADDRESS ADDRESS
2226 Cameo Road
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA 92008
PHONE IFAX PHONE IFAX 760-707-3726
EMAIL EMAIL
m.trostrud@hotmail.com I STATE UC.# STATE UC.# lCLASS r CITY BUS. UC.#
/Service at no cost to owner\
{Sec. 7031.5 Business and Professions Code: Any Crty or County which requires a permit to construct, alter, improve, demohsh or repair any structure, prior to its issuance, also requires the
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or That he is exet1111t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars t$500}).
Workers' Compensation Declaration: f hereby affirm under penalty of perjury one of the following declarations:
B I have and will maintain a certificate of consent lo self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. Policy No. Expiration Date,~-------~
"pi.il!,seclion need not be completed if the permit is for one hundred doUars ($100) or less.
LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage ls unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided forln Section 3706 of the Labor code, interest and attorney's fees .
..2$ CONTRACTOR SIGNATURE DATE
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
0
0
D
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. lf, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sa!e).
1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license law}.
I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Qves []No
2. I {have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm} lo provide the proposed construction (include name address I phone I contractors' license number):
4. I plan lo provide portions of the work, butt have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I conlractom' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address f phone f type of work):
JlS PROPERTY OWNER SIGNATURE ': DATE ·z.{)t lp
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 2:5533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? D Yes Cl No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O Yes a No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes O No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLWTION CONTROL DISTRICT.
I certify that I have read the application and state that the above infonnatlon is cmrectartd that the information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA perm[ is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height
EXPIRATION: E'.very pem1it issued by the Building Official under the provisions of this Code shall expire by fimitation and become null and void if the building orwosk. authorized by such permit is not commenced within
180 days from the date of such permit or if the building or work authorized by such pemi[ is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unifomi BuilcHng Code).
,fl$ APPLICANT'S SIGNATURE DATE
Permit Type: BLDG-Residential Application Date: 06/14/2016 Owner:
Work C!ass: Addition Issue Date: 08102/2016 Subdivision:
Status: Closed -Finaled Ei:piration Date: 0210212018 Address:
!VR Number: 715162
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
09/18/2017 09/18/2017
September 18, 2017
BLDG-Final
Inspection
034763-2017
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Passed Paul Burnette
COMMENTS
TRUST TROSTRUD FAMILY
TRUST 07-28-92
CHESTNUT HEIGHTS
2226 Cameo Rd
Carlsbad, CA 92008
Re inspection
Passed
Yes
Yes
Yes
Yes
Yes
--
Complete
Complete
Page2of2
Porrnit Type: BLDG-Residential Application Date: 06/14/2016 Owner: TRUST TROSTRUO FAMILY
TRUST 07-28-92
Work Class: Addition Issue Date: 08/02/2016 Subdivision: CHESTNUT HEIGHTS
Status: Closed -Finaled Expiration Date: 02/02/2018 Address: 2226 Cameo Rd
Carlsbad, CA 92008
!VR Number: 715162
"""""'""""""''~~ """'"""~"·'"~'''"-''"' -·~·-"-"'~"''""'
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
~="--·==·----~ .... %·-~--······-~-·~·-·
11/07/2016 11/07/2016 BLDG-15 000042-2016 Passed Andy Krogh Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/08/2016 11/08/2016 BLDG-18 Exterior 000228-2016 Passed Andy Krogh Complete
Lath/Drywall
Checklist item COMMENTS Passed
BLDG-Building Deficiency Yes
11/21/2016 11/21/2016 BLDG-23 002106-2016 Passed Andy Krogh Complete
Gas/Test/Repairs
Checkllst Item COMMENTS Passed
BLDG-Building Deficiency For meter relocation Yes
11/23/2016 11/23/2016 BLDG-Electric Meter 002739-2016 Passed Andy Krogh Complete
Release
02/22/2017 02/22/2017 BLDG-13 Shear 014431-2017 Passed Andy Krogh Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior lath Yes
BLDG-17 Interior 014297-2017 Failed Andy Krogh Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code No
03/16/2017 03/16/2017 BLDG-84 Rough 016807-2017 Passed Andy Krogh Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
03/23/2017 03/23/2017 BLDG-17 Interior 017453-2017 Passed Andy Krogh Complete
Lath/Drywall
04/24/2017 04/24/2017 BLDG-27 Shower 020967-2017 Passed Andy Krogh Complete
Pan/Tubs
September 18, 2017 Page 1 of 2
Inspection History:
09/19/2016: 11-BLDG-Ftg/Foundation/Piers Approval Completed By AEK PERIMETER FTG;
10/12/2016: 11-BLDG-Ftg/Foundation/Piers Approval Completed By AEK;
09/19/2016: 21-BLDG-Underground/Under Floor Partial Approval Completed By AEK ADDITION// NEW
TO HOUSE AT OUTSIDE HOUSE-NOT CONNECTED YET;
10/12/2016: 21-BLDG-Underground/Under Floor Approval Completed By AEK
Print Date: 09/18/2017
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2226 Cameo Rd
BLDG-Residential
1670802900
$97,966.00
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit
www .carlsbadca.gov
Work Class: Addition
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Pian Check #:
Description: RESDNTL · RAD TROSTRUD: S7S SF MASTER STE. ADDITION// 104 SF ROOF DECK
Applicant:
TRUSTTROSTRUD FAMILYTRUST07-28·92
2226 Cameo Rd
CARLSBAD, CA 92008-2758
760-7737 x26
Total Fees:
Owner:
TRUSTTROSTRUD FAMILYTRUST07-28-92
2226 Cameo Rd
CARLSBAD, CA 92008-2758
760-7737 x26
Total Payments To Date:
Status:
Applied;
Issued:
Fina led:
Inspector:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOT!CE similar to this, or asto which the
statute of limitation has previously otherwise expired.
Permit No: CB162311
Closed -Fina/ed
06/14/2016
08/02/2016
A Krog
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-02-2016
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW160324
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
2226 CAMEO RD CBAD
SW PPP
1670802900
CB162311
TROSTRUD ADDITION
MICHAEL TROSTRUD
760 707-3726
Emergency Contact:
MICHAEL TROSTRUD
760 707-3726
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 0 Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
TROSTRUD FAMILY TRUST 07-28-92
2226 CAMEO RD
CARLSBAD CA 92008
ISSUED
07/19/2016
RMA
08/02/2016
1
L
$49.00
$59.00
$0.00
$108.00
Total Fees: $108.00 Total Payments To Date: $108.00 Balance Due: $0.00
TRUST 07-28-92
Work Class: Addition Issue Date: Subdivision: CHESTNUT HEIGHTS
Status: Closed -Finaled Expiration Date:
08/02/2016
02/02/2018 Address: 2226 Cameo Rd
Carlsbad, CA 92008
Scheduled
Date
Actual
Start Date
09/18(2017 09{18/2017
September 18, 2017
Inspection Type Inspection No.
BLDG-Final
Inspection
034763-2017
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
715162
Inspection Status Primary Inspector
Passed Paul Burnette
COMMENTS
Reinspection
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Page2of2
Permit Typo; BLDG-Residential App!ication Date: 06/14/2016 O>,,vner: TRUST TROSTRUD FAMILY
TRUST 07-28-92
Work Class: Addition Issue Date: 08/02/2016 Subdivision: CHESTNUT HEIGHTS
Status: Closed -Finaled Expiration Date: 02/02/2018 Address: 2226 Cameo Rd
Carlsbad, CA 92008
IVR Number: 715162
,~·=,-,me'"'"""~"'·""'"'"''"""'"-'_,, -""'·~,.,--,~='""""'"'™"'··-"--=~~~-=--=-,,.,..,.. ,.,.------
,->'•~'~'J',"H ,,.-,,---"~""·$·~··
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
11/07/2016 11/07(2016 BLDG·15 000042-2016 Passed Andy Krogh Complete
Roof/ReRoof (Patio)
Checklist !tern COMMENTS Passed
BLDG-Building Deficiency Yes
11/08(2016 11/08/2016 BLDG.18 Exterior 000228·2016 Passed Andy Krogh Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/21/2016 11/21/2016 BLDG·23 002106·2016 Passed Andy Krogh Complete
Gas/Test/Repairs
Checklist !tern COMMENTS Pas sod
BLDG·Building Deficiency For meter relocation Yes
11/2312016 11{2312016 BLDG·Electric Meter 002739·2016 Passed Andy Krogh Complete
Release
02/22/2017 02122/2017 BLDG-13 Shear 014431·2017 Passed Andy Krogh Complete
Panels/HD (ok to
wrap)
CheckHst item COMMENTS Passed
BLDG-Building Deficiency Exterior lath Yes
BLDG·17 Interior 014297•2017 Failed Andy Krogh Reinspection Complete
LathlDrywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code No
03/16/2017 0311612017 BLDG-84 Rough 016807·2017 Passed Andy Krogh Complete
Combo(14,24,34,44)
Checklist Jtem CO~!IMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame.Steel-Bolting-Welding
(Decks)
BLDG·24 Rough·Topout Yes
BLDG·34 Rough Electrical Yes
BLDG·44 Yes
Rough.Ducts-Dampers
0312312017 03(23/2017 BLDG·17 Interior 017453·2017 Passed Andy Krogh Complete
Lath/Drywall
04/2412017 04/2412017 BLDG-27 Shower 020967-2017 Passed Andy Krogh Complete
Pan/Tubs
September 18, 2017 Page 1 of 2
Carlsbad 16-2311
06/24/2016
<~i CITY OF
CARLSBAD
SPECIAL INSPECTION
AGREEMENT
B-45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carisbadca.gov
In accordance with Chapter 17 of the California BulldlnS Code the following must be completed when work bl!lng performed
requites special inspection, structural observation and construction material testing.
'rojecVPermit: CB 16-2311 2226 Cameo Road Project Address:. ········-··--------
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZEDAGENT. Please check if y_ou are ONnet~Buitder
00. (If you checked as o\M1er-buildar you must also complete Section B of this agreement)
Name: (Please pJintt __ ~j~hael W (fi1;I) -~(1.1~1-) ---------tlu\t)
Trostrud
Mailing Address:..?.??_6_C:_am_~c:>__l39_a_cl, __ c;_a_rlsb.ii<:l0 CA 92008
Email· m.trostrud@holmail.com Phone:...1.60 70.,_7-"3"-7""26e._ __ _
I am: e3Property owner !JProperty owner's Agent of Record EJArchitect of Record DEngineer of Record
State of California Registration Number.:........_~~-Expiration Date:
AGREEMENT; I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construcllon materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code.
Signatur~·----------------------Date: ____ ·-···----------·---
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder I owner-builder.
Conlractor's Company Name: Coastal Construction Please check lf you are OWner-Builder ~
Name: (Pleaseprlnl) __ ~M=a~rk~---------= (F,rsl) tl,11)
Deprelis
(La;tJ
Mailing Address: 4254 Trieste Dr Carlsbad, Ca 92010
Email: Mark@coastalconstructionsite.com Phone; __ (I§.Q)..434-5132
Stale of California Contractor's License Number: __ L_i_c_. #_B_-6_2_2_6_2_5 __ Expiration Date: 07/31/2017
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans:
• I acknowledge 1hat control will be exercised to obtain conformance with the construction documents approved by the
building official;
• l will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribulion of the reports; and
• I certify that I will ha qua · rson wi · tractor's} organization to exercise such control.
• I will re I lett r m liance with C Section 1704 •• 2 Ii or tor. uest/n ttnal
Ins I L
Signature;___ ___ Date: "6 / Zb l 0 _
I
g.45 Page 1 of 1 Rev. 06/11
DATE: 07/27/2016
JURISDICTION: Carlsbad
PLAN CHECK NO.: 16-2311
EsGil Corporation
In !Partnersfiip witfi government for (]Jui{tfing Safety
SET: II
PROJECT ADDRESS: 2226 Cameo Rd
PROJECT NAME: Trostrud SFR Addition
CJ APPLICANT
~IS
CJ PLAN REVIEWER
CJ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
[8J The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
[8J EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contac~ I)(} Telephone#:
Date contacted: ~bu ) Email:
Mail Telephone Fax In Person
[8J REMARKS: Clouded notes made to sheets A-1 and S-2.
By: Dwight Ashman
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
07/21/2016
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
DATE: 06/24/2016
JURISDICTION: Carlsbad
PLAN CHECK NO.: 16-2311
EsGil Corporation
In (Partnersnip witn government for (]Jui(aing Safety
SETI
PROJECT ADDRESS: 2226 Cameo Rd
PROJECT NAME: Trostrud SFR Addition
~ j)PPLICANT
~JURIS.
0 PLAN REVIEWER
0 FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Michael Trostrud
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
~ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Michael Trostrud Telephone#: (760)707-3726
Aate cony3cted: VJ/i-=j--(by:{y., Email: m.trostrud@hotmail.com
l:::::Mail olTelephone Fax In Person
D REMARKS:
By: Dwight Ashman
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
06/16/2016
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 16-2311
06/24/2016
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 16-2311
PROJECT ADDRESS: 2226 Cameo Rd
FLOOR AREA: 575 S.F.
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 06/14/2016
DATE INITIAL PLAN REVIEW
COMPLETED: 06/24/2016
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
STORIES: 2
HEIGHT: NC
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 06/16/2016
PLAN REVIEWER: Dwight Ashman
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 16-2311
06/24/2016
• PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Indicate on the Title Sheet of the plans the name of the person responsible for
the preparation of the plans. Section R106.1.1.
3. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
4. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code).
5. Provide a north arrow, and dimensions to property lines for the addition.
6. Clarify the roof deck. Based on the framing plans this appears new. Please
address the following:
a) How is it accessed? Show new or existing door along with
headers/framing as required.
b) Show 2nd floor plan.
c) Show light and electrical receptacle.
d) Show deck covering, and ICC approval.
e) Show minimum Y.":12" slope for drainage.
f) Show guard on all open sides. It appears as if a % wall will be used, show
height and detailing.
Carlsbad 16-2311
06/24/2016
7. On the cover sheet of the plans, specify any items that will have a deferred
submittal (trusses?). Additionally, provide the following note on the plans:
"Submittal documents for deferred submittal items shall be submitted to the
registered design professional in responsible charge, who shall review them and
forward them to the building official with a notation indicating that the deferred
submittal documents have been reviewed and that they have been found to be in
general conformance with the design of the building. The deferred submittal
items shall NOT be installed until their design and submittal documents have
been approved by the building official."
• FIRE PROTECTION
8. Please indicate on the plans whether the existing residence has a fire sprinkler
system installed. If so, then provide a note stating that any additions/alterations
will be provided with an automatic residential fire sprinkler system. Section
R313.2.
9. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space, or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.3.1. Also show or note locations
of smoke alarms in the existing house.
10. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2. Also show or note locations of CO alarms in
the existing house.
• GENERAL RESIDENTIAL REQUIREMENTS
11. Glazing in the following locations should be shown on the plans as safety glazing
material in accordance with Section R308.4:
a) Glazing in doors.
Carlsbad 16-2311
06/24/2016
• EXITS, STAIRWAYS, AND RAILINGS
12. Guards (Section R312):
a) Shall be installed along open-sided walking surfaces that are located
more than 30" above the floor or grade below.
b) Shall have a height of 42" (may be 34" along the sides of stairs).
c) Openings between railings shall be less than 4". The triangular openings
formed by the riser, tread and bottom element of a guardrail at a stair
shall be less than 6".
d) Shall be detailed to show capability to resist a concentrated load of 200
pounds in any direction along the top rail. Table R301.5.
• ROOFING
13. Specify on the plans the following information for the roof materials, per Section
R106.1.1:
a) Manufacturer's name and product name/number.
b) ICC approval number, or equal.
14. Show the required ventilation for attics (or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1 /150 of attic area ( or 1 /300 of attic area if at least 40% (but not more
than 50%) of the required vent is located no more than 3' below the ridge). Show
on the plans the area required and area provided. Section R806.2.
15. Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with 1/16" minimum to Y." maximum openings.
Section R806.1.
16. Show location of attic access with a minimum size of 22"x30", unless the
maximum vertical headroom height in the attic is less than 30". Access must be
provided to each separated attic area (if over 30 sq. ft.), shall be located in a
hallway or other readily accessible location and 30" headroom clearance is
required above the opening. Section R807.1.
• CONCRETE AND MASONRY
17. Provide material specifications for: concrete, CMU, grout, mortar, and reinforcing
steel.
18. Call out new slab thickness and reinfocement.
19. Show foundation bolt size and spacing. Foundation bolt size and spacing for
braced walls must be clearly shown on the foundation plan. Section R403.1.6.
20. Show that anchor bolts will have plate washers not less than 3"X3"X0.229" along
braced wall lines.
Carlsbad 16-2311
06/24/2016
21. Provide details for the installation of retrofit anchor bolts. This may be required
along the wall between the stair and sitting room. Note that special inspection is
required. Complete and return the attached special inspection form.
• FRAMING
22. Specify nail size and spacing for the floor and roof diaphragms on the plans.
Table R602.3(1 ).
23. Show double top plate with minimum 48" lap splice. Section R602.3.2.
24. Provide truss details and truss calculations for this project. Specify truss
identification numbers on the plans. If deferred annotate on the cover sheet as
outlined in item # 7 above.
25. Please note that per table R602.10.5 the 1 '-11" braced wall panel shown at the
sitting room does not provide any of the required bracing. However the wall
between the sitting room and stair can be applied to the same line as they are
only 3' offset. Please provide a dimension for this wall, and there will be more
than adequate bracing on the line.
26. Provide a minimum 1800 lb hold-down at the right side of the sitting room, on the
panel end closest to the door. This is required as it does not reach the end of
the braced wall line. See R602.10.2.2.1 exception 2.
• ELECTRICAL
27. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
• PLUMBING
28. Please include a gas pipe sizing design (isometric or pipe layout) for all gas
loads. This is required based on the installation of a new water heater. See
California Energy Code (ES) 150.0(n). The piping should be sized for a water
heater load of 200000Btu.
29. Show an electrical receptacle within 3' of the water heater. ES 150.0(n).
30. Show the T and P relief valve at the water heater and the discharge pipe size
and routing to the exterior. CPC Section 608.3.
Carlsbad 16-2311
06/24/2016
31. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California S8407.
• RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code which became effective January 1, 2011 and must be enforced by the
local building official. The following mandatory requirements for residential construction
must be included on your plans. CGC Section 101.3. The Standards apply to newly
constructed residential buildings, along with additions/alterations that increase the
building's conditioned area, volume or size. CGC Section 303.1.1. Please either add
additional or revise provided notes as applicable.
32. Note on the plans that automatic irrigation system controllers shall comply with
the CGC Section 4.304.2 as follows: A. Controllers shall be weather or soil
moisture based that automatically adjust irrigation in response to changes in
needs as weather conditions change. B. Weather based controllers shall have
separate wired or wireless rain sensor which connects or communicates with the
controller(s). Soil moisture based controllers are not required to have rain
sensors.
33. Recycling. Note on the plans that a minimum of 50% of construction waste is to
be recycled. CGC 4.408.1. Provided note indicates 30%.
34. Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content
needs to be certified by one of 3 methods specified in Section 4.505.3. Building
materials with visible signs of water damage should not be used in
construction. The moisture content must be determined by the contractor by
one of the methods listed in CGC 4.505.3. The bold, underlined portion of
this note is lined out. It appears that this may be a printing error and not
intentional?
35. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star
rated, vented directly to the outside and controlled by a humidistat. CGC
4.506.1.
36. Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances,
etc.) for the owner at the time of final inspection. CGC 4.410.1.
Carlsbad 16-2311
06/24/2016
37. Recycling. Note on the plans that the contractor shall submit a Construction
Waste Management Plan to the jurisdiction agency that regulates waste
management, per CGC 4.408.2.
38. ENERGY CONSERVATION
39. Include all applicable sections of the MF-1 R form with the plans.
40. All hot water piping sized %" or larger is required to be insulated as follows: 1"
pipe size or less: 1" thick insulation; larger pipe sizes require 1 %" thick insulation.
Note: In addition, the %" size hot water pipe to the kitchen sink is required to be
insulated. ES 150.00)2
41. Residential energy lighting requirements: ES 150.0(k)
• In bathrooms. at least one fixture shall be high efficacy and all remaining
fixtures shall be high efficacy or be controlled by a vacancy sensor.
Other lighting notes ok. Unable to find the bathroom requirements on the plans.
42. Residential ventilation requirements:
• Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the
exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or
some similar source of moisture".
• Residential bathroom exhaust fans shall be energy star rated and shall be
control by a humidistat capable of an adjustment between 50 and 80%
humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not
required if the bathroom exhaust fan is also the dwelling whole house
ventilation.
• All fans installed to meet all of the preceding requirements must be specified
at a noise rating of a maximum 1 "Sane" (for the continuous use calculation)
or 3 "Sane" (for the intermittent use calculation).
Carlsbad 16-2311
06/24/2016
• MISCELLANEOUS
43. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
44. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes D No D
45. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Dwight Ashman at
EsGil Corporation. Thank you.
Carlsbad 16-2311
06/24/2016
SPECIAL INSPECTION
AGREEMENT
B-45
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural obseivation and construction material testing.
Jrojectf Permit: ______ _ ___ Project Address: _________________ _
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder
0. (If you checked as owner-builder you must also complete Section B of this agreement.)
Name: (Please print~---
ic,rs11 lhll) '.L~5l)
Mailing Address_·_ ·-----------------------------------
Email_· ________ ·-----------------Phone: ___________ _
I am: UProperty O\,vner llProperty Owner's Agent of Record OArchitect of Record UEngineer of Record
State of California Registration NumbeL·-------------Expiration Date: ________ _
AGREEIV1ENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code
Signature-: _______________________ Date: ___________ _
8. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder I owner-builder
Contractor's Company ~Jame: __ ··-··------------· Please check if you are Owner-Builder 0
t'-Jame: (Please print)_c _________________________________ _
;f,rs(i (11111.i (LsstJ
Mailing Address: ___________ .
Email:_ ... ________________________ Phone: _________ _
state of California Contractor's License Number: _______ Expiration Date: _______ _
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control vi1ill be exercised to obtain conformance with the construction documents approved by the
building official;
• I 'Nill have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I v1iJI have a qualified person within our (the contractor's) organization to exercise such control.
• I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final
inspection.
Signature ________ Date: ___________ _
8·45 Page 1 of 1 Rev. 08/11
Carlsbad 16-2311
06/24/2016
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 16-2311
PREPARED BY: Dwight Ashman
BUILDING ADDRESS: 2226 Cameo Rd
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Addition 575 City Est
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
Bldg. Permit Fee by Ordinan~c• __ •...JJ
Plan Check Fee by Ordinance
Type of Review: 0 Complete Review
D Repetitive Fee 3 Repeats
D Other
D Hourly
EsGil Fee
DATE: 06/24/2016
Reg. VALUE ($)
Mod.
95,916
95,916
~ $604.88j
$393.171
D Structural Only
l------11Hr. @ *
$338.731
Comments: In addition to the above fee, an additional fee of $43 is due (0.5 hour@
$86/hr.) for the CalGreen review.
Sheet 1 of 1
macvalue.doc +
City of
Carlsbad
PLAN CHECK
REVIEW
TRAN SM ITT AL
DATE: 06/16/2016 PROJECT NAME: TROSTRUD FAMILY ADDITION
PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2226 CAMEO RD
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www .carlsbadca.gov
PROJECT ID:CB162311
APN: 167080290
VALUATION: $95,916 SCOPE OF WORK: ADD 575 SF TO EXISTING FOOTPRINT
D
This plan check review is complete and has been APPROVED by:
LAND DEVELOPMENT ENGINEERING DIVISION
Final Inspection by Construction Management & Inspection Division is required: Yes No ,X
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: M.TROSTRUD@HOTMAIL.COM
To determine status by one of the divisions listed below, please contact 760-602-2719.
760-602-4624
Chris.Sexton@carlsbadca.gov Gregory.Rya11@carlsbadca.gov
Gina
760-602-4675
Gina.Ruiz@carlsbadca.gov
Remarks:
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
:x··-·1 ValRay Nelson
L_J 760-602-2741
ValRay.Marshall@carlsbadca.gov
Cindy V\/ong
760-602-4662
Cy11thia.Wo11g@carlsbadca.gov
Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
TROSTRUD FAMILY ADDITION PLAN CHECK NO# 1
Please Read
Instructions:
Outstanding issues are marked with !Xi Items that conform to permit
requirements are marked with 1 ,/ or have intentionally been left blank.
NO CITY
OWNED
EASEMENTS
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale. Show:
North arrow
Existing & proposed structures
Existing street improvements
Property lines (show all dimensions)
Easements
Right-of-way width & adjacent streets
Show on site plan:
Driveway widths
' Existing or proposed sewer lateral
Existing or proposed water service
Submit on signed approved plans:
DWGNo.
Drainage patterns and proposed site elevations. Show all high points.
Building pad surface drainage must maintain a minimum slope of one percenttowards an adjoining
street or an approved drainage course.
__ __]ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
Existing & proposed slopes and topography
[::::] Size, location, alignment of existing or proposed sewer and water seNice(s) that seNes the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
] Site address
Assessor's parcel number
Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.: LOT 22 MAP 5328
Subdivision/Tract: CHESTNUT HEIGHTS
Reference No(s):
E-36 Page 2 of 6 REV 6/01/12
TROSTRUD FAMILY ADDITION PLAN CHECK NO# 1
N/A
N/A 30 FT
EXISTS
ACCORDING
TO MAP ON
CHESTNUT
DOES NOT
MEET
THRESH HOLD
E-36
2. DISCRETIONARY APPROVAL COMPLIANCE
Project does not comply with the following engineering conditions of approval for project no.:
3. DEDICATION REQUIREMENTS
Dedication for all street rights-of-way adjacent lo the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 24 000 00 , pursuant lo Carlsbad Municipal Code Section 18.40.030.
Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS
··1AII needed public improvements upon and adjacent to the building site must be constructed
1 at lime of building construction whenever the value of the construction exceeds
$120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
. Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee, so we may prepare the necessary Neighborhood
Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit.
Future public improvements required as follows:
Page 3 of 6 REV 6/01/12
TROSTRUD FAMILY ADDITION PLAN CHECK NO# 1
N/A
E-36
5. GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
Inadequate information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
L Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector The inspector will then
provide the engineering counter with a release for the building permit.
No grading permit required.
Minor Grading Permit required. See additional comments for project-specific requirements.
6. MISCELLANEOUS PERMITS
··RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work
-~ adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
Right-of-way permit required for:
*ANY WORK BEING DONE WITHIN THE PUBLIC RIGHT OF WAY*
Page 4 of 6 REV 6/01/12
TROSTRUD FAMILY ADDITION PLAN CHECK NO# 1
E-36
7. STORM WATER
Construction Compliance
Project Threat Assessment Form complete.
Enclosed Project Threat Assessment Form incomplete.
Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form
and return (SW )
Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Development (SUSMP) Compliance
Storm Water Standards Questionnaire.
Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
Indicate areas of impervious surfaces (patios.walkway, etc. ) and pervious areas (landscaping).
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
Bio-retentions cell/rain garden
Pervious pavement/pavers
Flow-through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
Other:
Page 5 of 6 REV 6/01/12
TROSTRUD FAMILY ADDITION PLAN CHECK NO# 1
8. WATER METER REVIEW
Domestic (potable) Use
DOES NOT
EXCEED
THRESH HOLD
9. FEES
DRAINAGE
DOES NOT
AFFECT 100 YR
RUN OFF
What size meter is required?
Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be%".
Required fees have been entered in building permit.
Drainage fee applicable
Added square feet
Added square footage in last two years?
Permit No.
Permit No.
Project built after 1980
Impervious surface> 50%
Impact unconstructed facility
yes
yes
yes
no
Fire sprinklers required :~]yes
Upgrade yes
no (is addition over 150' from center line)
r··-·ino ,-~-"
No fees required
10. ADDITIONAL COMMENTS
Attachments: Engineering Application Storm Water Form Right-of-Way Application/Info. Reference Documents
E-36 Page 6 of 6 REV 6/01/12
••• Fee Calculation Worksheet ...
ENGINEERING DIVISION
Prepared by: Date: GEO DATA: LFMZ: I B&T:
Address: Bldg. Permit#:
Fees Update by: Date: Fees Update by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq.Ft./Units
Types of Use: Sq.Ft./Units
Types of Use: Sq.Ft./Units
Types of Use: Sq.Ft./Units
ADT CALCULATIONS: List types and square footages for all uses.
Types of Use:
Types of Use:
Types of Use:
Types of Use:
FEES REQUIRED:
Sq.Ft./Units
Sq.Ft./Units
Sq.Ft./Units
Sq.Ft./Units
EDU's:
EDU's:
EDU's:
EDU's:
AD T's:
AD T's:
AD T's:
ADT's:
Within CFD: []YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) iZNO
1. PARK-IN-LIEU FEE:[]NW QUADRANT NE QUADRANT []SE QUADRANT []W QUADRANT
ADT'S/UNITS: I X FEE/ADT: I =$
2.TRAFFIC IMPACT FEE:
ADT'S/UNITS: I X FEE/ADT: I =$
3. BRIDGE & THOROUGHFARE FEE: DIST. #1 DIST.#2 DIST.#3
(USE SANDAG)ADT'S/UNITS I X FEE/ADT. I =$
4. FACILITIES MANAGEMENT FEE ZONE:
ADT'S/UNITS: 1x FEE/SQ.FT./UNIT: I =s
5. SEWER FEE
EDU's 1x FEE/EDU: I=$
BENEFIT AREA:
EDU's 1x FEE/EDU: I =$
6. DRAINAGE FEES: PLDA: [[]HIGH MEDIUM r--iLOW ----J
ACRES: 1x FEE/AC: I=$
7. POTABLE WATER FEES:
UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL
•••This may not represent a comprehensive list of fees due for this project.
Please contact the Building division at (760) 602-2719 for a complete listing of fees***
STORM WATER COMPLIANCE FORM cs'lbt'3) \ TIER 1 CONSTRUCTION SWPPP
E-29 swltfJ -?,!Jr1
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE I
STORM WATER POLLUTION PREVENTION NOTES
Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials
1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE BMPs Control BMPs Management BMPs Pollution Control BMPs
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLA110N ~ OF EROSION AND SEDIMENT CONlROL BMPs WHEN RAIN ~ t :§ m • ~ • IS EMINENT. .,, 6 g ·E .~ 6 i §
,l! 5 ~ ~ cg i 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION ~. m .!i! .. i~ ~ '>-t <-I i~ m 6~ 8-.E 6 -~ Best Management Practice* .. .5 w fr " C • .,, 6 .,_ 0. CONTROL DEVICES TO WORKING ORDER TO THE SA TlSF ACllON £ •• -~ ,= .5 u .. u ~ • ~ ~ tis •• 3' • (BMP) Description -3, .~ § "' m •m w ~] ~-!, C C ~ OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING . ,i :s ~ e 8 5i ,ll ~-~ ]~ ]~ CC 0 , E 2~ I C 0 g' 0 o m i !~ ~1 RAINFALL. C .:' ~ E g = :i: U8 en:;:, c1l ~-~ it I ~ g' b g' el 't·~ g. ,g 11 • • Jg ,g ~~ ]8 .s :g ii -s ~o
i, Ji .se ~J ,; :g § NC cc
3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION • !, o e ~ "' e ~ o e ~vi ~o O 0 oo
~ we ul ~> m~
'" C
~~ ;,,~ ~c ~ ~ ~u ~~ ~" u~
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY 0 INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR CASQA Designation ~ ~ w ~ -~ ~ ~ ~ ~ w N ~ ~ w ' N ~ ~ ~ ~ w
' ' ' ' ' ' ' ' ,1 ~ ,1 J, ' ' ' ' ' ' ' ' ' ' ' ' UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. i;l i;l u u l7l.~ w IJi I' I' ~ ~ ~ ~ ;.! ;.! ;.! ;.! ;.! ;.! ;.!
"' Construction Activity w w ~ ~ ~ ~ z z z z
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE " Gradino/Soil Disturbonce ' AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) Trench inc/Excavation
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT Stockoillno
(40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER Drillinn 1B0rinn
EACH RAINFALL ConcretelAsnhalt Sawcuttinn .
ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM -1.,oncrete Flotwork " 5. P.i;ivino
AGGREGATE. onduit/Pine lnstallotlon '
6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER SJucco/Mortar Work
PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST asle Disoosal
BE INSTALLED AND MAINTAINED. Starin ov Down Area <'
Eouioment Maintenance and Fuelin"
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER Hazardous Substance Use/Storace
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED Dewaterinn
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY Site Access Acres~ rurt ~
REGULATIONS. Other I lisll: r -,.c ' " ,, '" ~ " .,,
Instructions: P, ,. ~
1. Check the box to the left of all applicable construction activity (first column) expected lo occur during construction.
2. Located olong the top of the BMP Tobie is a list of BMP's with It's corres~onding California Stormwoter Quallty Association (CASQA) designation number. or more BMPs you intend to use during construction from the list. Check he box where the chosen activity row intersects with the BMP column. Choose one
3. Refer to the CASQA construction handbook for information and details of the chosen BMPs ond how to apply them to the project.
OWNER'S CERTIFICATE: -
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: {1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION PROJECT INFORMATION k.J ACTIVillES TO THE MAXIMUM EXlENT PRACllCABLE TO AVOID
TI-IE MOBIUZAllON OF POLLUTANTS SUCH AS SEDIMENT AND TO Site Address: ·1J:{,:L:6;. CJl.U.tP __ .
AVOID THE EXPOSURE OF STORM WATER TO CONSlRUCllON SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE
r I 0"J 6t!PZ'ta: RELAlED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL llMES, ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN. Assessor's Parcel Number:
COMPLY WITH THIS CITY APPROVED "TIER 1 CONSlRUC110N SWPPP SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE
TI-IROUGHOUT THE DURAllON OF THE CONSTRUC110N AC11VlTIES EROSION CONTROL PLAN. I Emecgeacy Co~toc), J.A Gt. _f/..o ,I/ f j
UN11L TI-IE CONSTRUCTION WORK IS COMPLETE AND APPROVED \ Name: .vuciL I s,
BY THE CITY OF CARLSBAD.
24 Hour Phone: '7 (.e O 1.0] ?-i Z.< f11c.UA""1..-~Q.;,sf: ~ LOWNERlSJ10'7,~N·~'r:; . r l , 1 _ 1 1 G Construction Threat to Storm Water Quality
{Check Box) [iJ1ow OWNERlS)/OWNER S A ENT l'l"M . \=• 11.'lREJ ATE 0 MEDIUM
E-29 J Page 1 of 1 REV 02/16
xx a xx xx xx -----I
SCALE:
LEGEND
• DWG.NO. SYMBOL
SILT FENCE
FIBER ROLL
PRESERVAnON OF EXISnNG
INLET PROTF:CnON
GRAVEL BAG BERM/BARRIER
DIRECTION/COURSE OF FLOW
5£-1
5£-5
EC-2
SE-10
SE-6
HYDRAULIC MULCH/HYDROSEED EC-1. EC-4
STABILIZED CONSTRUCTION ENTR4NC£ TR-I
MATERIALS OEUVERY AND STORAGE AR£4 WM-1
TEMPORARY TRASH/SOLID WASTE WM-5
HAZARDOUS AND CONCRETE WM-6, WM-8
WASTE MANAGEMENT
S4NITARY WASTE WM-9
(PORTABLE TOILET)
N4-5'45'45"W
-0--0--
-x-x-x-x-
~
ffllllllllllffl
I WM-I I
I WM-5 I
I ~~=~ I I WM-91
~STANDARD DRAWINGS (5£-5, WM-5, ETC.) CAN BE FOUND AT THE
CALIFORNIA STORMWATER QUALITY ASSOCtAnoN (CASQA) WEBSITE: http://www.cabmphcmdbooks.com/
QUANTITY
(city of
Carlsbad
DETERMINATION OF
PROJECT'S SWPPP
TIER LEVEL AND CONSTRUCTION
THREAT LEVEL
E-32
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
I'm applying for: a Gradipg Per!llit · Building Permit . a Right-of~ permit a Other
Project Name:. ,z;Z,Zh if "I~ {IA Project ID_ :C~ \ (p-z s ll DWG #/CB#', I (p -'2..;,I k
Address: 1:tfl&cJ»,tcJD CM-I.SW5cA-' APN I (12JOW "Z"\00 Disturb~a: L \OD~~ .Ae-
Section 1: Determination of Project's SWPPP Tier Level
(Check annlicable criteria and circle the correspondina SWPPP Tier Level, then AO to section 2)
Exempt -No Threat Project Assessment Criteria
My project is in a category of permit types exempt from City Construction SWPPP requirements. Provided
no significant grading proposed, pursuant to Table1, section 3.2.2 of Storm Water Standards, the
following permits.are exempt_fromSWPPP __ requirements:
i > Electrical i > Patio i > Mobile Home l > Plumbing i > Spa (Factory-Made) ................ . .................. ; ............................................ ·............. . ............. ~ ....................................... ;................................ . ...................................... · i > Fire Sprinkler : > Mechanical : > Re-Roofing ! > Sign i > Roof-Mounted Solar Array ,.... .. ............................ ·., ......................................... , .......................... ·······················;···· ................................. ·.... .. ...................................... •
Tier 3-Significant Threat Assessment Criteria -(See Construction General Permit (CGP) Section 1.8)*
D My project includes construction or demolition activity that results in a land disturbance of equal to or
greater than one acre including but not limited to clearing, grading, grubbing or excavation; or,
D My project includes construction activity that results in land disturbance of less than one acre but the
construction activity is part of a larger common plan of development or the sale of one or more acres
of disturbed land surface or,
D My Project is associated with construction activity related to residential, commercial, or industrial
development on lands currently used for agriculture; or
D My project is associated with construction activity associated with Linear Underground/overhead
Projects (LUP) including but not limited to those activities necessary for installation of underground
and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire,
towers, poles, cables, wires, connectors, switching, regulating and transfonming equipment and
associated ancillary facilities) and include but not limited to underground utility mark out, potholing,
concrete and asphalt cutting and removal, trenching, excavation, boring and drilling, access road,
tower footings/foundation, pavement repair or replacement, stockpile/borrow locations.
D Other per CGP
Tier 2-Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat
Assessment Criteria described above and meets one or more of the following criteria:
D Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the
Carlsbad Municipal Code); or,
D Project will result in 2,500 square feet or more of soils disturbance including any associated
construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance
areas and project meets one or more of the additional following criteria:
• located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or,
• disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or
• disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or
watercourse; and/or
• construction will be initiated during the rainy season or will extend into the rainy season (Oct 1
through Apr. 30).
Tisr'1-Low Threat Assessment Criteria
!!!:I My project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt
permit type per above and the project meets one or more of the following criteria:
• results in some soil disturbance; and/or
• includes outdoor construction activities (such as roof framing, saw cutting, equipment washing,
material stockpiling, vehicle fueling, waste stockpiling)
SWPPP
Tier Level
Exempt
Tier 3
Tier2
Tier 1
* Items listed are excerpt from CGP. CGP governs cntena for triggers for Tier 3 SWPPP. Developer/owner shall confirm coverage
under the current CGP and any amendments, revisions and reissuance thereof.
E-32 Page 1 of 2 Rev. 2/16/16
SWPPP Section 2: Determination of Project's Construction Threat Level
Tier {Check applicable criteria under the Tier Level as determined in section 1, circle Construction
Level the corresponding Construction Threat Level, then complete the Threat Level
signature block below)
Exempt -Not Applicable -Exempt
Tier 3 -High Construction Threat Assessment Criteria: My Project meets one or more of the
following:
D Project site is 50 acres or more and grading will occur during the rainy season
D Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed,
inside or within 200 feet of an environmentally sensitive area {ESA) or discharges directly
to an ESA High
D Soil at site is moderately to highly erosive (defined as having a predominance of soils Tier3 with USDA-NRCS Erosion factors kf greater than or equal to 0.4)
D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1 -April 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
Tier 3 -Medium Construction Threat Assessment Criteria Medium D All projects not meeting Tier 3 High Construction Threat Assessment Criteria
Tier 2 -High Construction Threat Assessment Criteria: My Project meets one or more of
the following:
D Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or
within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an
ESA
D Soil at site is moderately to highly erosive (defined as having a predominance of soils High
with USDA-NRCS Erosion factors k, greater than or equal to 0.4)
Tier2 D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1-Apr. 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
D Site results in 10,000 sq. ft. or more of soil disturbance
Tier 2 -Medium Construction Threat Assessment Criteria Medium D My project does not meet Tier 2 High Threat Assessment Criteria listed above
Tier 1 -Medium Construction Threat Assessment Criteria: My Project meets one or more
of the following:
D Owner/contractor received a Storm Water Notice of Violation within past two years Medium D Site results in 500 sq. ft. or more of soil disturbance
Tier 1 D Construction will be initiated during the rainy season or will extend into the rainy season
(Oct.1-April 30)
Tier 1 -Low Construction Threat Assessment Criteria Low D My project does not meet Tier 1 Medium Threat Assessment Criteria listed above
I certify to the best of my knowledge that the above statements are true and correct. I will prepare and submit an appropriate tier level SWPPP as determined above
prepared in accordance with the City SWPPP Manual. I understand and acknowledge that I must adhere to and comply with the storm water best management
practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the permit type(s) checked above.
The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where it can be shown
that a lesser or higher SWPPP Tier Level is warranted.
Owner/Owner's Authorized Agent Name: Title: City Concurrence: Yes No
(For City Use Only)
Owner/Owner's Authorized Agent Signature: Date: By:
Date:
Project ID:
E-32 Page 2 of 2 Rev. 2/16/16
«~;,
¥c1TYOF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
DATE: 7-19-16 PROJECT NAME: PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov
PLAN CHECK NO: CB 16-2311 SET#: 2 ADDRESS: 2226 Cameo Rd APN: 167-080-29-00
~ This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required D Yes ~ No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: m.trostrud@hotmail.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
D
D
760-602-4624
Chris.Sexton@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Remarks:
760-602-2784
Christopher.Glassen@carlsbadca.gov
D ValRay Marshall
760-602-27 41
ValRay.Marshall@carlsbadca.gov
D Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
Greg Ryan
760-602-4663
Gregory.Ryan@carlsbadca.gov
Cindy Wong
760-602-4662
Cynthia.Wong@carlsbadca.gov
D Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
REVIEW#:
1 2 3
~DD
~DD
~DD
~DD
~DD
Plan Check No. CB 16-2311 Address 2226 Cameo Rd Date 7-19-16 Review# Z
Planner Chris Sexton Phone (760) 602-4624
APN: 167 -080-29-00
Type of Project & Use: addition Net Project Density: 1.0 DU/AC
Zoning: R-1-10.000 General Plan: R-4 Facilities Management Zone: 1
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: · ~ Item Complete D Item Incomplete -Needs your action
Environmental Review Required: YES D NO D TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not. state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
OTHER RELATED CASES:
DATE
YES D NO D TYPE --
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES O NO 0
CA Coastal Commission Authority? YES O NO 0
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive.
Suite 103, San Diego. CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES D NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds. Activity Maintenance. enter CB#. toolbar. Screens. HMP Fees. Enter Acres of
Habitat Type impacted/taken. UPDATE!)
lnclusionary Housing Fee required: YES D NO D
(Effective date of lnclusionary Housing Ordinance -May 21. 1993.)
Data Entry Completed? YES D NO D
(A/P/Ds. Activity Maintenance, enter CB#. toolbar, Screens. Housing Fees. Construct
Housing Y/N. Enter Fee, UPDATE!)
~ D D Housing Tracking Form (form P-20) completed: YES D NO D N/A D
P-28 Page 2 of 3 07/11
Site Plan:
i:gJ DD Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES D NO D
2. Project complies: YES D NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required 20' Shown 20'
Required 7.5' Shown 7.5'
Required __ Shown __
Required 1§'. Shown 20'
Required __ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __
Interior Side: Required __ Shown __
Street Side: Required __ Shown __
Rear: Required __ Shown __
Structure separation: Required __ Shown __
3. Lot Coverage: Required <40% Shown 23%
4. Height: Required <30' with min. 3:12 roof pitch Shown 23'4"
5. Parking: Spaces Required i Shown i
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required __ Shown __
6. Floor Area Ratio: Required __ Shown __
Additional Comments 1) Please show the dimension for the front yard setback to ensure the
front yard setback is in compliance. 2) What is the dimension of the wet bar? Per the
Carlsbad Municipal Code the wet bar cannot exceed one and a half inches in diameter, a
depth of eighteen inches and an overall size of two square feet. Note place on plans meets
wetbar definition. Counter tops or cabinets do not exceed 8 linear feet 3) Please
provide the lot coverage. It cannot exceed 40%.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Chris Sexton DATE 7-19-16
P-28 Page 3 of 3 07/11
PLANNING DIVISION
BUILDING PLAN CHECK
CITY Of REVIEW CHECKLIST
CARLSBAD P-2s
DATE: 6-15-16 PROJECT NAME: PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov
PLAN CHECK NO: CB 16-2311 SET#: 1 ADDRESS: 2226 Cameo Rd APN: 167-080-29-00
D This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required D Yes IXI No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
[:gJ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: m.trostrud@hotmail.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING·.. -·· i:~GIIIIEERING -
760°602,.4£1!)~~---··1-----c:---·· "l:60-602-2750
~ Chris Sexton D Chris Glassen
D
D
760-602-4624
Chris.Sexton@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Remarks:
760-602-2784
Christopher.Glassen@carlsbadca.gov
D ValRay Marshall
760-602-27 41
ValRay.Marshall@carlsbadca.gov
D Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
FIRE PREVENTIQN
~~160·602-4665.-'"-.
D Greg Ryan
760-602-4663
Gregory.Ryan@carlsbadca.gov
D CindyWong
760-602-4662
Cynthia.Wong@carlsbadca.gov
D Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
REVIEW#:
1 2 3
[g] D D
P-28
Plan Check No. CB 16-2311 Address 2226 Cameo Rd Date 6-15-16 Review# 1
Planner Chris Sexton Phone (760) 602-4624
APN: 167-080-29-00
Type of Project & Use: addition Net Project Density: 1.0 DU/AC
Zoning: R-1-10 000 General Plan: R-4 Facilities Management Zone: 1
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: 12'] Item Complete D Item Incomplete -Needs your action
Environmental Review Required: YES O NO O TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES O NO O TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES D NOD
CA Coastal Commission Authority? YES D NOD
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES O NO 0
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of
Habitat Type impacted/taken, UPDATE!)
lnclusionary Housing Fee required: YES D NO D
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Data Entry Completed? YES O NO 0
(NP/Ds, Activity Maintenance, enter CB#, too/bar, Screens, Housing Fees, Construct
Housing Y/N, Enter Fee, UPDATE!)
Housing Tracking Form (form P-20) completed: YES D NO D N/A D
Page 2 of 3 07/11
Site Plan:
DOD
i:gJ D D
i:gJ D D
DOD
DOD
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES D NO D
2. Project complies: YES D NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required 20' Shown __
Required 7.5' Shown 7.5'
Required __ Shown __
Required 1§'. Shown 20'
Required __ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __
Interior Side: Required __ Shown __
Street Side: Required __ Shown __
Rear: Required __ Shown __
Structure separation: Required __ Shown __
3. Lot Coverage: Required <40% Shown __
4. Height: Required <30' with min. 3:12 roof pitch Shown 23'4"
5. Parking: Spaces Required I Shown I
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required __ Shown __
6. Floor Area Ratio: Required __ Shown __
Additional Comments 1) Please show the dimension for the front yard setback to ensure the
front yard setback is in compliance. 2) What is the dimension of the wet bar? Per the
Carlsbad Municipal Code the wet bar cannot exceed one and a half inches in diameter, a
depth of eighteen inches and an overall size of two square feet. 3) Please provide the lot
coverage. It cannot exceed 40%.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
P-28 Page 3 of 3 07111
10 OJINSULATION, L.P.
lril Insulation/Fireplaces
Insulation Certificate
Fed. Id# 205576054
lic.#888804
Your Home/Building has been insulated with Certainteed Fiberglass Insulation products, which are designed for
today's safety standards and tomorrow's energy requirements. Fiberglass is inorganic and therefore permanently
noncombustible, so it does not have to be treated with fire-retardant chemicals that will likely lose their
effectiveness over time. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will
not absorb moisture nor will it settle over time as many other insulation materials.
This also certifies that Certainteed Fiberglass Insulation has been professionally installed in this home/building to
provide the following thermal performance and meets Title 24 requirements.
Insulation is installed in the structure described below as follows:
Work Area Item Installed
Attic Area -Batts
Attic Area -Batts
Exterior Walls and Rim Joists
Wire
Caulk and Seal exterior doors, windows and sill plates
Job Name: Trostrud Residence
Job Address: 2226 Cameo Rd
Carlsbad. CA 92008
R-30 24" x 48" -Unfaced -CertaPro -Batts
IB.3RTS248-PC RMAX 2"x4'x8' Soard
R-19 15.25" x 48" -Unfaced -Batts
ISW17G Wire 17 Gauge 1/4 Ml. Spool
CF812 Foam
* Expandable Foam caulking to meet Title 24 Air Infiltration Standards is Included
Signed , :Z 6 ~
Tom Berry -Director of es
Date: March 23, 2017
Square Footage
458
128
720
!Piece
458
R-Means resistance to heat flow. The higher the R-value, the greater the insulating power. Ask your builder for
the fact sheet on R-values. Keep this certificate with your other valued papers. If you ever sell this
home/building, this certificate should be passed on to the buyer.
Azusa Branch #872
600 S Vincent Ave
Azusa, CA 91702
Phone: (626) 812-6070
Palm Springs Branch #873, #876
72-060 Corporate Way
Thousand Palms, CA 92276
Phone:{760)834-3355
Escondido Branch #874
2061 Aldergrove Ave
Escondido, CA 92029
Phone:(760)839-3200
fJ;;.,;c':.
(_ City of
Carlsbad
CERTIFICATION OF
SCHOOL FEES PAID
B-34
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit. The City will not issue any building permit without a completed school fee form.
Project Name: TROSTRUD ADDITION Project ID:
Building Permit
Plan Check Number: C=B..,_16:,2:.:3~1..,_1 _____________________ _
Project Address:
A.P.N
Project Applicant
(Owner Name):
Project Description:
Building Type:
Residential:
2226 CAMEO RD
167-080-29-00
Michael Trostrud
Addition to habitable space
NEW DWELLING UNIT($)
Square Feet of Living Area in New Dwelling/s
Second Dwelling Unit: Square Feet of Living Area in SOU
Residential Additions: 575 Net Square Feet New Area
Commercial/Industrial: Net Square Feet New Area
City Certification of
Applicant Information, -~~--•~<ft:_hheg. __________ D_at_e_7_1_19_1_2_01_6 _____ _
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
~ Carlsbad Unified School District
6225 El Camino Real
Carlsbad CA 92009 (760-331-5000)
D Encinitas Union School District-
By appointment only
101 South Rancho Santa Fe Rd
Encinitas, CA 92024
(760-944-4300 x1166l
D Vista Unified School District D San Marcos Unified School District
1234 Arcadia Drive 2 5 5 P i c o A v e S t e . 1 o o
Vista CA 92083 (760-726-2170) xt San Marcos, CA 92069 (760-290-2649)
2222 Contact: Nancy Dolce (By Appl. Only)
D San Oieguito Union High School District-By Appointment Only
684 Requeza Dr.
Encinitas, CA 92024
(760-753-6491 X 5514)
Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury
that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner
will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number
of dwelling units or square footage after the building permit is issued or if the initial determination of units or square
footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or
that the person executing this declaration is authorized to sign on behalf of the Owner.
Signature:
1'.'1-.. n'l1nn
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
***************************************************************************************************
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District, certifies that
the developer, builder, or owner has satisfied the obligation for school facilities. This is
to certify that the applicant listed on page 1 has paid all amounts or completed other
applicable school mitigation determined by the School District. The City may issue
building permits for this project.
SIGNATURE OF AUTHORIZED SCHOOL
DISTRICT OFFICIAL
TITLE
NAME OF SCHOOL DISTRICT
DATE
PHONE NUMBER
Tu ' 'Js, /\0, (' ~kl ('-.l'fa,J,J-Q l~ . (:,u.. "V\. v-e i v'<'.L,,,,j
s'--, p-e v: 'i h +-k:X', cLrM
CARLSBAD UNIFIED SCHOOL DISTRICT
6225 EL CAMINO BEAL
CARLSBAD, CA 92009
'I ·o--O -/ b
B-34 Page 2 of 2 Rev. 03/09
Print Date: 09/19/2017
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2226 Cameo Rd
BLDG-Migrated
1670802900
$ 0.00
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Permit
www.carlsbadca.gov
Work Class: BLDG-Migrated
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Status:
Applied:
Issued:
Finaled:
Inspector:
Permit No: PCR16201
Closed -Finaled
10/07/2016
11/17/2016
09/19/2017
Description: PCR -TROSTURD: ADD SHOWER IN POWDER ROOM & REPLACING SEWER LINE FROM SAME AREA
Applicant:
TRUSTTROSTRUD FAMILY TRUST 07-28-92
2226 Cameo Rd
CARLSBAD, CA 92008-2758
760-7737 x26
BUILDING PLAN CHECK FEE (BLDG)
Total Fees: $ 107.50
$107.50
Total Payments To Date : $ 107.50 Balance Due: $ 0.00
(city of
Carlsbad
PLAN CHECK REVISION
APPLICATION
8-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Plan Check Revision No. PCR_ \lQ 2.0 \ Original Plan Check No.CG, ilo--Z.3 l \
ProjectAddress ZZ.2.-4,C-~W~ ~b&J)d\Cjrz..oob Date 10{7{11.:,
Contact J-"\,c..u.b.l=L'"'T~'i"!L0.b Ph 1(;;,010·1 3'12..(p Fax
Email V\,'T\Z.0'5Tt2-0 D ~..j.pT't-,IAIL, COM
Contact Address Z:Z .. 7...(p CJll'\ t'D eJ C
General Scope ofWorl<
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised:
~ Plans D Calculations D Soils D Energy D Other
2. 3.
Describe revisions in detail List page(s/ where
each revision is
shown
WG D\~co\l~D-nlb.r-ouLutJ{.')~ND
c..t:,..c,. { 111.o µ it Pe':> iv ctll e.b To '(?-,:~ ?E ft.AceD .
../'i.N!::>"'\ ~<t)~~~t) ~ I ?,0e!) ~ t; 't !d'.s ," e.'fS",td_)
Jl,.f~Je-D "TUl $ fL-~. ~ .Douu .:IS, ~i IL';,
f'ocil()c'L-~k t-,:l~S\""D bS ~oL. t .Sll-oo
IN (J f\bc\...'\O ~ Ov'1 \J-\ I> 8..~.
~ AS, L,)E K \!>IJ ,L.-):) l'--\c=: ·~w ll..0or\. I Lls
c.suo~ 1....b L1 '4---"'t' .-v .J\D D .r:.. ~""well.-'To ~ /:;.,-z.
?A\\.\~ok, v ~,s .11..u ~ t:'I t..Qut>.f'B'" T>J.!.r' sc!wlr
"-1.\t: c1Ct s.1n t-1 ~ "'f'L v k ~v .. :i 1.t .•
5.
6.
7.
8.
Does this revision, in any way, alter the exterior of the project? D Yes
Does this revision add ANY new floor area(s)? D Yes
Does this revision affect any fire related issues? D Yes
IZ) No
~No
4.
List revised sheets
that replace
existing sheets
A --z._
~No
Fax: 7 60-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
Carlsbad 16-2311
06/24/2016
~ <<t t4,/_' ': ",'¥ C ITV OF
CARLSBAD
SPECIAL INSPECTION
AGREEMENT
B-45
Development Seryices
Building Division
163S faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special iospcctlon, structural observation and eonstruetion material testing.
'roject/Permit: CB 16-2311 Project Address: _2_22_6_C_an_1_eo Road
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORl2:ED AGENT. Please check if you are Owner-Builder
ll!l. (If you checked as 01M1et-bttilder you must also complete Section B of this agreement)
Name: (PleeseprintL_~_!~hael W Trostrud
[firrll (Mt.) !L~~)
Mailing Address· 2226 Cameo Road, Carlsbad, CA 92008
Email· m.trostrud@hotmail.com . ___ Phone:_?60 707 3726
I am: !!Property owner OProperty owner's Agent of Record CJArchitect of Record OEngineer of Record
state of California Registration Numbet-.............-·----·-,.·-·. Expiration Date: ___ _
AGREEMENT: I, the undersigned, declare under penally of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
obseivations, construolion materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code.
Signatur~·----------------Dale: _______ _
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706}, This section must be completed by the
contractor I builder I owner-builder.
Contractor's Company Name: Coastal Construction Please check if you are O'Mler·Bullder M
Name: (Pleaseprint) __ .,cM"'a"'r_,_,1<=-c_·-------= (Fil~!] !/,II}
Depretis
tLi.:t)
Mailing Address: 4254 Trieste Dr Carlsbad, Ca 9201 O
Email: Mark@coastalconstructionslte.ccm Phone:_(Ill_Q)..434:513=2~-~
Stale of California Contractor's License Number: __ L_ic_._#_B_-_62_2_6_2_5 __ Expirallon Date: 07/31/2017
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
I acknowledge ihat control v,m be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures for exercising cont,rol within our (the contractor's) organizauori, for the method and
frequency of reporting and the distribution of the reports; and
+ I certify that I will ha qua· rson wi · . ractor's) organization to exercise such control.
• I will r vi lie r m Ii nee with Sect on 1704 1.2 , or to~ uest/n final
Ins I L
Signature;_-~ Date: ~ / lC::J{ 0 I
ll-45 Paga 1 of1 Rev. 06/11
EsGil Corporation
In rPartnersnip witn qovemment for CJ3ui[<fing Safety
DATE: 11/02/2016
JURISDICTION: Carlsbad
PLAN CHECK NO.: 16-2311 (PCR16-201)
PROJECT ADDRESS: 2226 Cameo Rd
PROJECT NAME: Trostrud SFR Addition
SET: II REV. I
D APPLICANT
~RIS.
D PLAN REVIEWER
D FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:,,---/.l Telephone#:
Date contacted: ,.----(uy{/' VJ Email:
Mail Telephone Fax In Person
D REMARKS:
By: Dwight Ashman
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
10/27/2016
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In <Partnership with government for (}Juiftfing Safety
DATE: 10/19/2016
JURISDICTION: Carlsbad
PLAN CHECK NO.: 16-2311 (PCR16-201)
PROJECT ADDRESS: 2226 Cameo Rd
PROJECT NAME: Trostrud SFR Addition
SET I REV. I
0/APPLICANT M JURIS.
0 PLAN REVIEWER
0 FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
l:gJ The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
i:gJ The applicant's copy of the check list has been sent to:
Michael Trostrud
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
l:gJ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Michael Trostrud Telephone#: (760)707-3726
Date contacted: l 0/,9/lb(by:.JI() Email: m.trostrud@hotmail.com
J I-Mail \/Telephone Fax In Person
D REMARKS:
By: Dwight Ashman
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
10/13/2016
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 16-2311 (PCR16-201)
10/19/2016
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 16-2311 (PCR16-201) JURISDICTION: Carlsbad
PROJECT ADDRESS: 2226 Cameo Rd
FLOOR AREA: NC
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 10/07/2016
DATE INITIAL PLAN REVIEW
COMPLETED: 10/19/2016
FOREWORD (PLEASE READ):
STORIES: 2
HEIGHT: NC
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 10/13/2016
PLAN REVIEWER: Dwight Ashman
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 16-2311 (PCR16-201)
10/19/2016
• PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Please verify if any of the walls that are moved are shearwall/braced wall.
3. Provide connection details for new walls.
a) If braced walls, detail shear transfer, anchor bolts etc.
b) If not braced walls detail top and bottom connections.
4. Show a GFCI receptacle within 3' of the lavatory. CEC 210.52(D)
5. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be
either:
a) A 20 ampere circuit dedicated to each bathroom, or
b) At least one 20 ampere circuit supplying only bathroom receptacle outlets.
6. Show stud size, height and spacing on the plans. Maximum allowable stud
heights shall be per Table R602.3(5).
7. Residential energy lighting requirements: ES 150.0(k)
• In bathrooms. at least one fixture shall be high efficacy and all remaining
fixtures shall be high efficacy or be controlled by a vacancy sensor. Show
lighting in the new bathroom.
Carlsbad 16-2311 (PCR16-201)
10/19/2016
8. Residential ventilation requirements:
• Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the
exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or
some similar source of moisture".
• Residential bathroom exhaust fans shall be energy star rated and shall be
control by a humidistat capable of an adjustment between 50 and 80%
humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not
required if the bathroom exhaust fan is also the dwelling whole house
ventilation.
• All fans installed to meet all of the preceding requirements must be specified
at a noise rating of a maximum 1 "Sane" (for the continuous use calculation)
or 3 "Sane" (for the intermittent use calculation).
Show ventilation in the new bathroom.
• MISCELLANEOUS
9. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
10. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes D No D
11. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Dwight Ashman at
EsGil Corporation. Thank you.
Carlsbad 16-2311 (PCR16-201)
10/19/2016
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
201)
PREPARED BY: Dwight Ashman
BUILDING ADDRESS: 2226 Cameo Rd
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
·----·
Bl . P rmi Or in nee ... dgetFeebyda ~
Plan Check Fee by Ordinance
Type of Review: D Complete Review
0 Repetitive Fee -~ ;~j Repeats
" Based on hourly rate
Comments:
D Other
0 Hourly
EsGil Fee
PLAN CHECK NO.: 16-2311 (PCR16-
DATE: 10/19/2016
Reg. VALUE ($)
Mod.
~ /07.'50
D Structural Only
1 IHr.@ *
~=====$=8=6 ·=o~o $86.001
Sheet 1 of 1
macvalue.doc +
(city of
Carlsbad
Owner: -fW;rl2_.D .D
WASTE MANAGEMENT
PLAN
B-59
Job Address: Z?J,,(ei (N'.{EV ~ CMls~D
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Permit#: Estimated Cost of Project: $ __ 1_5D __ ;,_a:CJ ________ _
Type of Project: J8) New Construction D Remodel or T.I. ~Residential D Commercial
(check all that apply) ~Other ...1,t>l)ITio!,J 'I'? c:}(\SllPC Sf.'12-,
DDemolition
Non-hazardous construction waste generated during the. course of this project shall be recycled and/or salvaged for re-use at a
minimum of 50% per CALGreen Sec. 5.408.1. Failure to comply may result in a penalty fee up to $1,000. For projects which
consist of mainly equipment and/or racking, that have a combined weight of new construction disposal that does not exceed 2
lbs per square foot of building area affected by this permit, may be deemed to meet the 50% minimum requirement upon
approval of Building Department.
ALTERNATIVE FORMS OF COMPLIANCE: (If selected, do not complete Tables 1 & 2 below)
D Construction waste shall not exceed 2 lbs. per sf. of area. All receipts shall be provided to the Building Official prior to
final. (This option not applicable for most construction projects.)
Square feet of construction area X 2 lbs. = lbs. of allowable waste.
D I plan on using a WASTE MANAGEMENT roll-off bin. All receipts shall be provided to the Building Official prior to final.
Table 1 -Estimated Waste (To be filled out prior to permit issuance -refer to example on Page 2.)
MATERIALS lbs. of waste to be taken to lbs. of waste to be Waste Hauling Company or Re-Use Method LANDFILL RE-USED or RECYCLED
Asphalt/ Concrete
Brick/ Masonry
Cardboard
Drywall
Landscape Debris
Lumber I Wood
Metals
Mixed Waste
Trash I Garbafl.:e
Other:
TOTAL lbs:
Estimated Percentage to be Re-Used or Recycled ______ %
I certify that the information provided herein, to the best of my knowledge, is true and correct.
Contractor or Owner (print name)
Contractor or Owner (signature) Date
Official Use Only
D Plan Approved D Plan Denied D Project Valuation Approved
Reviewed/ Approved by: _________________ _
Page 1 of 2
Table 2 -Actual Waste (To be completed atter construction.)
MATERIALS I bs. of waste ta ken to lbs. of waste Waste Hauling Company or Re-Use Method
LANDFILL RE-USED or RECYCLED (complete only if different than Table 1)
Asphalt/ Concrete '"5,(p~ y\ = J:s"\ s. '\;'.:D~LL (. I \2-S )
Brick/ Masonry
Cardboard l '5b Ml.-S . LJV.:. f':,~ cJ~/' c -ff1).cE •
Drywall
Landscape Debris ~ -~~D AcJL! Sc'l...~1 C€. \ ,-:, l-.
Lumber/ Wood
Metals
Mixed Waste
Trash I GarbMe I Z-00 ,iLS 1_/W !:i<:eJV' c ..\ -.rl.,c;1: •
Other:
TOTAL lbs.: \'fOO 1t>BO
Actual Percentage Re-Used or Recycled,_ ..... B"'".i?""-___ %
Offigial Use Only
Ja'50% Goal Achieved D 50% Goal Not Achieved D Alternative Compliance Achieved Penalty Paid $ _______ _
Reviewed/ Approved by: ___________________ _
EXAMPLE: Use the following example as a guide to completing this form.
MATERIALS lbs. of waste to be taken to lbs. of waste to be
LANDFILL RE-USED or RECYCLED
Asphalt I Concrete 0 ::woo
Brick I Masonry 100 450
Cardboard 0 150
Drywall 0 50
Landscape Debris 0 1::?.0
Lumber I Wood 500 0
Metals 300 ::?.00
Mixed Waste 1500 0
Trash I Garbage 300 0
Other: Pool c;u.,,Lte 0 900
TOTAL lbs.: ::?.J-00 3'2J-O
Percentage to be Re-Used or Recycled 59 %
Formula:
Total Re-used or Recycled X 100 = % Re-Used or Recycled
(Total Combined Waste)
Waste Hauling Company or Re-Use Method
Al;G H~ull'1-Cl Go.
WM I R.e-vLSed i;rkiz 0'1--slte
Al;G rM ul[.,,r, Go.
Al;G H~uli'1-Cl Go.
Mult~ed E; Re-used 0'1--.slte
w~ste M~"'~11ev1,ce.,,t
WM I Ai;c H~uli"-0
WM
WM
vLSed ~.s cru.s~ed i;~.se ovc-.site
3870 X 100 = 59% Re-Used or Recycled
(2700 + 3870)
Since 59% exceeds the minimum requirement of 50%, this plan complies.
Page 2 of 2
'
Agri Service, Inc
3720 Oceanic Way
Suite 204
Oceanside.CA · 92056
Customer: CASH
Cash Customer
Truck 5452
Trailer
Material: B40
Location: 0
Lie#: 7F10647
Weigh Master: CJS
Dnver:
Remarks: Thanks
Tipping at El Corazoo
Brush
Oceanside
CIS
-~----·------------····--·
c:, ,..
I-
"' I-a, -.. :,; :, 0
0 CD z ~
.... w ""' w ~ 0 =--co
sl i ii: w II)
I-"' :;;
.,,
-M
i-N z ::,
0 (.l
,~ § ..
$40.00/tn
Gross:
Tare:
fll 0 er <( ./. :i: (.l g er w 5 ...
w ~
X
"' Q
<( g
"
Ticket No : 138604
Date :8112/16
..
"' (.l ::,
[!:
Phone :(760)295--6255
Fax :(760)295--6262
.9 .. .6
"'a! ~ "O :i ., ~ "0 -~i a" .. ~ ., "' ~c gg
.0 J?
~i og 8·"-e ::i ii .. > >,
"'0 .,_
"! ti ll)..,..:g ="'" 0 i @' "'"' ~ !ff C gt -~ .. § § 'O
~ .,g
-C lj\ s ".:: $~cg
Ilg t
C .. .C %-fj u_ .. s
!-S 6 -o-gE-
Je_ o?fl. ~
.Q'C~IU = ~T""! <(,. _
Order No: 2
11460
8160
Loads:
Miles:
Tons:
Brush40
15,386
0
139.74
lb Scale 1
lb STORED
In 9:45am
Out 9:45 am
Net 3300 lb
1.650 tn
Material$ 66.00
Delivery$ 0.00
Misc$ 0.00
Tax$ 0.00
Total$ 66.00
Received$ 66.00
Check# 4