HomeMy WebLinkAbout2229 PALOMAR AIRPORT RD; ; CB060539; Permitr\
03-01-2006
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Sign Permit Permit No CB060539
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Reference #
Project Title
2229 PALOMAR AIRPORT RD CBAD
SIGN
2130702900 Lot #
$1270000 Construction Type
0
NEW
HAMPTON INN-2 SIGNS ILLUMINATE
& ELECT TO MONUMENT SIGN @ 6 FT HIGH
Applicant
PS SERVICES
SUITE B
316 E DYER RD 92707
714-513-1870
Status ISSUED
Applied 03/01/2006
RMA
03/01/2006
03/01/2006
Entered By
Plan Approved
Issued
Inspect Area
Owner
AGO HILLS L L C
C/O EDWARD G COSS
620 NEWPORT CENTER DR
NEWPORT BEACH CA 92660
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Electrical Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Additional Fees
$12279
$000
$7981
$000
$2000
$000
$000
$000
$000
TOTAL PERMIT FEES $222 60
Total Fees $222 60 Total Payments To Date $222 60 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exacticnsof which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
t j
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
FOR OFFICE USE OJ&ILY
PLAN CHECK NO
EST VAL
Plan Ck Deposit
Validated ByzliDate
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot No Subdivision Name/Number Unit No Phase No Total tt ol units
Assessor's Parcel It Existing Use Proposed Use
Descnption of Work SQ FT #of Stones # of Bedrooms # of Bathrooms
. ,_,.„ , ,
<*%-- ^c l/ij,~f67-7ef?J
Name Address State/Zip Telephone #Fax*
Name
i^fiffi^fiWoBiSliis
Address City State/Zip Telephone tt
^Name Addr City State/Zip Telephone tt
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom end the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars l$500l)
Name /•/<///£State License « 6 1 < I? fh
Address
License Class ^<O
City State/Zip
' ^" ^ Citv Business License #
Telephone #
/4s/+
Designer tfame
State License *
Address City State/Zip Telephone
,.
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
Q I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
Pu I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is
issued My worker s compensation insurance earner and policy number are •—*/ —
Insurance Company £ T^ Tel f~\s~Sl&f Policy No ( rf IUG-^~ c^O®--* Expiration Date ~r " / ~ " "
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
O CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California
WARNING Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and dvD fines up to one hundred
thousand dollars ($100 000) in addition to the cost of compensation damages as provided for In Section 3706 of the Labor code interest and attorney a fees
- - -/-o £SIGNATURE DATE
"4:8
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
n I. as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If however the building or improvement is
sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
0 I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
n I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES QNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? D YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? CD YES Q NO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
liilSiifil^ 2S1:I;Z;1, ^T'!!"; Z'VT./•'"""„.:'.:• ::JL'*":. rJI1- ^/^Si^II^Sf^vrSV1'-! ;-~$' •
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER S NAME LENDER S ADDRESS
i^;.^
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a penod^f 180 days (Section 106 4 4 Uniform Building Code) ^ '
APPLICANT S SIGNATURE DATE
WHITE File YELLOW Aoolicant PINK Finance
City of Carlsbad Bldg Inspection Request
For 11/14/2007
Permit* CB060539
Title HAMPTON INN-2 SIGNS ILLUMINATE
Description & ELECT TO MONUMENT SIGN @ 6 FT HIGH
Inspector Assignment
Type SIGN
Job Address
Suite
Location
APPLICANT PS SERVICES
Owner
Remarks
Sub Type
2229 PALOMAR AIRPORT RD
Lot 0
Phone 7147219462
Inspector
Total Time
CD Description
11 Ftg/Foundation/Piers
Signs
Act Comments
Requested By NA
Entered By CHRISTINE
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description Act Insp Comments
08/22/2007 11 Ftg/Foundation/Piers NR TP
CONSULTING
ENGINEERS
CORPORATt OITICE
n^ll Emily Court
Su^arLind Texis 77'i78
713/77') 7252
1 600 422 7252
!-ix 713/77'.! 117:)
LOUISVILLE KENTUCICV
502/426 678';
ORLANDO 1'LORIDA
107/SR1 rt200
City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
PLANNING
RECD BY
DATE
SIGN FEE
SIGN PROGRAM FEE
RECEIPT NO
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information
1 North arrow and scale
2 Location of existing buildings or structures, parking areas, and vehicular access points to the
property
3 Location of all existing and proposed signs for the property
4 Distance to the property line(s) for all proposed freestanding sign(s)
5 Provide an elevation for all proposed sign(s) which specifies the following
A Dimensions and area for all existing and proposed sign(s)
B Materials the sign(s) will be constructed of
C Source of Illumination
-! ' ."•
D Proposed sign copy ''"*
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE
The application must be submitted prior to 4 00 p m Average processing time 2 weeks
NAME OF PROJECT /-?*m/f>/z> t _L/7/7
ADDRESS OF PROJECT
ASSESSOR PARCEL NUMBER
RELATED PLANNING CASE NUMBER(S)
TYPE OF DEVELOPMENT
(a) Residential
(b) Commercial
(c) Office/Industrial
^(Hotel/Motel
(e) Service Station
(f) Prof Care
(g) Theater
(h) Govt/Church
(i) Public Park
(]) Produce Stand
(k) Nursery
(1) P-U/OSZone
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA
VILLAGE REDEVELOPMENT AREA YesQ
SIGN ORDINANCE YesQ
COASTAL ZONE YesQ
4»»4»««4««4444«
Form 10 Revised 12/04
YesQ No Ed Specific Plan Number .
No |~| Requires VR Approval
NO n
NoD
«4«««««»
Page 1 of 4
EXISTING SIGNS
TYPE
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
NUMBER SIGN AREA SIGN HEIGHT
PERMITS ISSUED FOR EXISTING SIGNS Yes
PROPOSED PERMANENT SIGNS
No Date
TYPE
Pole**
Monument**
Wall
Suspended
Directional
Canopy
Freestanding**
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
/
2
NUMBER
PROPOSED
/
Z
MAXIMUM
SIGN
AREA
-3d) fc
ISl&fy
i
PROPOSED
SIGN
AREA
^*/$*
^(f$
MAXIMUM
SIGN
HEIGHT
6'
zy*
PROPOSED
SIGN
HEIGHT
<f'
zy"
PROPOSED TEMPORARY SIGNS
TYPE
Construction**
For Sale**
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
-
PROPOSED
SIGN
HEIGHT
**Pnor to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard Page 3 of 4 illustrates an example for what would be required for such proposed signs
Form 10 Revised 12/04 Page 2 of 4
SITE PLAN REQUIREMENT FOR POLE. MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter Additional time will be required for on-site inspection
Show building /s
P/L
\~J.."
i /
Show all property hnes ] ;
i •, •
•
S
curb line •"
Sight Visibility
1
i
Sight Distance Requirem
1
1
1
how setbacks from all cv
I
1
1
1
Street Name (s)
1
i
ent
irbs
North
21 41 080 Sign design standards
Relationship to Streets Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway
Form 10 Revised 12/04 Page 3 of 4
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ FT)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ FT )
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
ft
. sq ft
.sq ft
.sq ft
. sq ft
.sq ft
OWNER
NAME (PRINT OR TYPE)
MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE
/^i^/-/-/^*^, <£A 12&6O <f<ff~//o-V'ai>
\ CERTIFY THAT /AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE
SIGNATURE DATE
APPLICANT
NAME (PRINT OR TYPE)
MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE
•f ~^t?-)r?o
I CERTIFY THAT/I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE
SIGNATURE DATE
PLANNER CHECK LIST
1
2
3
4
5
6
Field check by planner
Within maximum length, area
Style consistent with Sign Program and/or Specific Plan criteria, if applicable
Location •!• In right-of-way
*> In visibility triangle at corner
Pole and monument signs to be checked by Traffic Engineering, for visibility issues
When approved route copy to Data Entry
APPROVED Planner Date
Form 10 Revised 12/04 Page 4 of 4
f EN3 CAPS and S"UCE CON>nic\
8
-1 TRANS? BOX-
mr\i~
10
A
fi
(ftHI
71ma
in
O
insi0.3S ssa) |>
2
c ^d 5>Ci 3 i— O O :J rf Wifells « ?M£2 rip r- •£»»-» ^g ^g > -n »
8§gf So || gj;?3
111 |l ^3s = !
H SS fflft 0 > ^ ~4 0 > SAJO ^<5 ^3 * u? .*- 5 70
Z in70 Z "K 3 M U> Km *>K ? > § ?n zS n (?> *"™° Win m™ g -1 TO 0
s 1
AJ-n
5:
II
0
— i xiJTI C HI3lKD ig
/ w,v Z g
/ *// fr —/ r- ?-,«<// 2 :/i>,^ 3m^|4J lb
i^ttjmm '^ •
!'^W>rVj. /-f/fft--] sr/ /£•'•*// ^ r=il^ffLJjL 1 ,.^|(y/^y ^,•' i H/'/ z*
5K ^ **lo o 3= 3n
p
1:— -, I
'r^o o
:Ci:
£*•Sf."-
•^~\, w
r^-J;•SECLPS 33 AMPSi
O
18J
SS§
ma
12/9/2005
11 12AM
Structural Engineering Calculations for
HAMPTON INN/HOMEWOOD SUITES
Carlsbad, CA
6' x 4' D/F Monument Sign
Index
Title
Specifications
Wind Loads
Supports
Footing
1
2
3
4
5
Prepared by
Tom Holden, Technical Director
Chandler Signs, LP
1335 Park Center Drive, Suite B
Vista, CA 92081
Sheet 1 of 5
12/9/2005
11 12AM
SPECIFICATIONS
Project HAMPTON INN/HOMEWOOD SUITES
Descript 6' x 4' D/F Monument Sign
Steel
Design and fabrication according to AISC-ASD, 9th edition
Plate, angle, channel, tee and wide flange ASTM A36
Round pipe ASTM A53 Grade B or equivalent
Square and rectangular tube ASTM A500 Grade B
High strength bolts ASTM A325, bearing type connections (snug tight)
Machine bolts ASTM A307
Anchor bolts or threaded rod ASTM A36
Steel for reinforced concrete Grade 60
Welding
Design and fabrication according to AWS D1 1
AWS certification required for all structural welders
E70XX electrodes for SMAW processes
F7X-EXXX electrodes for SAW processes
Concrete
Design and construction according to ACI 318-89, revised 1992
Compressive strength at 28 days, fc= 2,500 psi minimum
Concrete poured into constrained earth excavations must cure under proper
conditions for 4 days prior to sign box installation ( Exception if the overall height
of the sign is less than 20 feet and the sign pole is adequately braced against wind
loads for a minimum of 4 days, the box may be installed the same day as the
footing is poured )
For pier and caisson footings, concrete must be poured against undisturbed earth
Maintain a minimum 3" concrete cover over all embedded steel
Sheet 2 of 5
12/9/2005
11 12AM
WIND & SEISMIC LOADS
Project HAMPTON INN/HOMEWOOD SUITES
Descript 6' x 4' D/F Monument Sign
Ref Uniform Building Code 1994
Basic Wind Speed= 90
Exposure= c
Cq= 1 4
Height (ft)
mph, UBC figure 16-1
flat terrain, generally open for 1/2 mile
signs, flagpoles and hghtpoles, UBC table 16-H
Calculation of Design Wind Pressures
(qs)(Ce)(Cq) = Wind Pressure
15
20
25
30
40
60
80
100
120
160
200
300
400
207
207
207
207
207
207
207
207
207
207
207
207
207
1 06
1 13
1 19
1 23
1 31
1 43
1 53
1 61
1 67
1 79
1 87
205
219
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
308
328
345
357
380
41 5
444
467
485
520
543
595
636
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
Seismic Load Comparison
Seismic Zone= 1
Z= 01
l= 1 0
Cp= 20
Wp= 150
Fp= (Z)(l)(Cp)(Wp)= 2 3
UBC figure 16-2
standard structures
UBC table 16-P, signs
psf, typical sign box with structure
psf
Sheet 3 of 5
12/9/2005
11 12AM
COLUMN LOADS & DESIGN
Project HAMPTON INN/HOMEWOOD SUITES
Descnpt 6' x 4' D/F Monument Sign
Ref Manual of Steel Construction, AISC 9th Edition
Areas Subject to Wind Forces
Section
1
2
3
4
5
6
7
8
Description
Sign Box#1
Height Width Centroid
Feet Feet (Feet)
643
Area
(SQ ft)
2400
000
000
000
000
000
000
000
Wind
Pressure,
psf
308
00
00
00
00
00
00
00
Load
#
739
0
0
0
0
0
0
0
Total Load 739
Calculation of Design Forces at Critical Heights
y(ft)ooo
M(#')V(#)
2,216 739
Calculation of Bending Stress in Supports
#of
y(ft) Supports
0 1
Support
Type
Steel Pipe
Tube
Width or
Diameter
35
Tube
Depth
(N/A for
pipe, rod)
Wall
Thickness
0216
Allowable
Fb (ksi)
3070
Sx
1
Used
7241
Sx
Required
08660
Actual
Stress
(ksi)
1542
Check
OK
Column
Type
Column
Size
Allowable Bending Stresses
Criteria Stress increase factor= 1 33
Steel Pipe 3 50 d/t <3300/Fy so Fb= 066Fy= 307 ksi
Sheet 4 of 5
12/9/2005
11 12AM
LATERAL BEARING PIER AND CAISSON FOOTINGS
Project HAMPTON INN/HOMEWOOD SUITES
Descnpt 6' x 4' D/F Monument Sign
Ref Uniform Building Code 1994 (Sec 1806 7)
Round Pier Design
Top of Basic Lateral
Concrete Total Load Average Arm Moment per Load per Soil Stress Depth Used
Elevation # (feet) # of Piers P/er(#') Pier(#) (psf) (feet)
0 739 300 1
Diameter, b=
Minimum Depth, D= (A/2)(1+ SQR(1 + (4 36h)/A))=
S1=(q)(4/3)(2)(D/3)=
A=(234P)/(S1)(b)=
2216 739 150 400
1800 in, round augered hole
3 94 ft OK,< depth used
535 psf
215
Foundation Bearing Check
Allowable Bearing Pressure= 1,300 psf, 1994 UBC table 18-1 -A, at grade
Approximate Sign Wt per pier=
Base Wt=
Projected Base Area=
q max=
123
1,060
1 8
670
OK
Ib
Ib
sqft
psf,soil
Reinforcement Check
Concrete compressive strength 2,500
Max Tensile Stress (psi) 46
Mm Steel for temp shrinkage 0 3563
psi
<0 3Fc, No steel reinforcement required for bending
sq in
Concrete Volume
Volume of Concrete per Footmg=
Total Order Volume of Concrete=
0 26 cubic yards (+-) or
0 26 cubic yards (+-) or
707
707
cubic feet (+-)
cubic feet (+-)
Sheet 5 of 5
<D
(ft
m
v A R R o w
n 1111111 i-mm\ =
—04-6" SETBACK
|^ TO CURB
O
&5
o
mto
mI
t
*
s§i^V V
12ft
IffM 9 M« w 35 Q-
oO
3
3g
(D
?|||
II$H
r ii? ??
|| UIIf
pfs-• » S. ni
I
I
flH
Ml?151
rlr§ §ii
^5
o
o
4'-0"
m
m
m
m
o
m
m
Co OSfB
§r~m
CO
I
00
c
i
o
cm
O
D
W
5!33CD5
CD mD
cnn
(D
O
6'-0" OVERALL HEIGHT
STEEL POLE SUPPORTS / FOUNDATIONDETERMINED BY ENGINEERING.HOODm SIGN INTERNALLY-ILLUMINATED w/ 800nFLUORESCENT LAMPS.a
X
6 FABRICATED .063" ALUMINUM BASE & RBE PAINTED TO MATCH PMS 425 GRAY.m
g APPLIED VINYL:BACKGROUND - VT1937 BLUEOUTER BORDER - VT1936 REDINNER BORDER - VT1935 GREYCARTOUCHE - VT1935 GREYCOPY - SHOW-THRU WHITE.150" WHITE LEXAN FACES w/ 1st SURF/»0m "HAMPTON INN" CABINET FILLER & RET)PAINTED PMS 425 GREY.£
m
73 "DUCK" & RULE TO HAVE #3630-131 ME!GOLD VINYL APPLIED TO 1st SURFACE.>
i-
O .150" WHITE LEXAN FACES TO HAVE VT-GREEN VINYL BACKGROUND w/ WEEDEGRAPHICS TO BE SHOW-THRU WHITE.°io0
H (INSIDE OF CABINET TO BE PAINTED ST.LIGHT ENHANCING PAINT).m "HOMEWOOD SUITES" CABINET FILLERSIDE PAINTED PMS 425 GREY. RETAINEIPAINTED TO MATCH #3630-6949 TEAL Glm 9°
^f m ^<D/F INTERNALLY-ILLUMINATED .063" ALLMONUMENT SIGN.^Z
^m
S
I
CARLSBAO
O
I
TJ
g0
YARROW DI^AR AIRPORT73^?
>m
OB°
Q
1
HAMPTOz
zz