HomeMy WebLinkAbout2230 VISTA LA NISA; ; CBR2016-0189; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Print Date: 12/28/2016 Permit No: CBR2016-0189Residential Permit
www.carlsbadca.gov
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
2230 Vista La Nisa
BLDG-Residential
2552700100
$0.00
Work Class:
Lot #:
Reference #:
P/M/E Status:
Applied:
Issued:
11/28/2016
11/28/2016Construction Type:Finaled:
Closed - Finaled
Plan Check #:
Project Title:
Inspector:
Orig. Plan Check #:
Bathrooms:
Bedrooms:
# Dwelling Units:
Description:SERLET: INSTALL AC AND FURNACE
Contractor:
ASI HASTINGS INC.
4870 Viewridge Ave, Ste 200
SAN DIEGO, CA 92123-1671
619-590-9300
Owner:
TRUST CONLEY JACK B&CLARE L
2230 Vista La Nisa
CARLSBAD, CA 92009
Applicant:
JERMAINE MAEWEATHER
3645 Ruffin Rd, St. 330
San Diego, CA 92123-1845
619-590-9337
PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT $166.00
Total Fees:$166.00 Total Payments To Date:$166.00 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
I
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING D ENGINEERING 0BUILDING OFIRE 0HEALTH D HAZMATIAPCD
<<~1> Building Permit Application Plan Check No.~Q_ 2c \ b -0\ ~'1
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value ~ CITY 0 F Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Depqslt CARLSBAD email: building@carlsbadca.gov
www.carlsbadca.gov Date t\f~l\C.o lsWPPP
JOB ADDRESS SUITEf/SPACEf/UNITf IAPN 2230 VISTA LA NISA, CARLSBAD 92009 - --
CT/PROJECT # rOT# I PHASE# I# OF UNITS I# BEDROOMS #BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I DCC. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
INSTALL AC AND FURNACE
EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE II AIR CONDITIONING I FIRE SPRINKLERS
YES [}I N<O YES0No0 YESONoD
APPLICANT NAME JERMAINE MAEWEATHER PROPERTY OWNER NAME LUCI SERLET Prtnarv Contact
ADDRESS ADDRESS
3645 RUFFIN ROAD # 330·335 2230 VISTA LA NISA, CARLSBAD 92009
CITY STATE ZIP CITY STATE ZIP
san dieao ca 92123 CARLSBAD CA
PHONE I FAX PHONE I FAX 619-590-9337 (760) 845-6073
EMAIL EMAIL
JERMAINE@.WEGREENINC.COM
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME asi hastinas
ADDRESS ADDRESS 4870 viewridge ave
CITY STATE ZIP CITY STATE ZIP
san dieao ca 92131
PHONE I FAX PHONE I FAX 619-590-9337
EMAIL EMAIL
1ST ATE LIC. # STATE LJC.# I CLASS I CITY BUS. LJC.1200804 513115 c20
(Sec. 7031.5 Bus1ness and Professions Code: Any C1ty or County wh1ch requ1res a permit to construct, alter, Improve, demolish or repa1r any structure, pnor to 1ts Issuance, also requ1res the applicant for such permit to file a signed statement tl\at he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500}).
WORICERS' COMPENSATION
' ' '
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self·lnsure tor workers' compensation as provided by Section 3700 of the Labor Code, tor the performance of the work tor which this permit is issued. 0 I have and will maintain workers' compensation. as required by Section 3700 of the Labor Code. lor the pelformance of the work for which this oermlt is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. CYPRESS INSURANCE COMPANY Policy No. ASWC711636 Expiration Date 91112017
~section need not be completed H the perm~ is for one hundred dollars ($100) or less. U Certificate of Exemption: I certify that in the performance of for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
CaiHomia. WARNING: Failure to secure workers' is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided Labor code, Interest and attorney's fees •
.fl5 CONTRACTOR SIGNATURE
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D
D
D
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered tor sale (Sec. 7044, Business and Professions Code: The Contractors
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himseH or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burnen of proving that he did not build or improve tor the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law).
I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have ntracted (hired) the following persons to provide the work indicated (Include name I address I phone I type of work):
.fl5 PROPERTY OWNER SIGNATURE 0AGENT DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? a Yes a No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? a Yes a No
Is the facility to be constructed v.ithln 1 ,000 feet of the outer boundary of a school site? a Yes a No
IF J!Jjy OF THE J!JjSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES J!JjD THE AIR POLLUTION CONTROL DISTRICT.
I certifythatl have read the applcation and state that the above Information Is correct and that the information on the plans is accurate. I agree to complyv.ith all City ordinances and State laws relating to building constructioo.
I hereby authorize representative of the City ri Carlsbad to enter upon 1he above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL UABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA pennk is required tor excavations OVfl( 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every penni! issued by the Buikling Official under 1he prolo1sions is Code shall expire by limkation and become null and void ~ 1he building or work authorized by such penni! is not commenced within
180days from the date of such pennkor ~the buiding or work authorized by s k is suspended or abandoned at anytime after the work is commenced for a period of 180 days (Section 106.4.4 Un~orm Buikling Code).
~APPLICANT'S SIGNATURE DATE
PERMIT INSPECTION HISTORY REPORT (CBR2016-0189)
BLDG-Residential 11/28/2016Application Date:Permit Type:Owner:TRUST CONLEY JACK B&CLARE
L
Subdivision:P/M/E 11/28/2016Work Class:Issue Date:
2230 Vista La Nisa
Carlsbad, CA 92009-8711
Address:05/30/2017Expiration Date:Status:
IVR Number: 466
Closed - Finaled
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection CompleteActual
Start Date
12/28/2016 12/28/2016 BLDG-43 Air
Cond./Furnace Set
007340-2016 Passed Andy Krogh Complete
BLDG-Final
Inspection
007339-2016 Passed Andy Krogh Complete
COMMENTS PassedChecklist Item
BLDG-Mechanical Final Yes
BLDG-Electrical Final Yes
December 28, 2016 Page 1 of 1
---------------------------
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 1 of3)
Project Name: 2230 Vista La Nisa Enforcement Agency: City of Permit Number: CBR2016-0189
Carlsbad
Dwelling Address: 2230 Vista La Nisa [Main] City: Carlsbad Zip Code: 92009
A. System Information
01 Space Conditioning System Identification or Name System 1
02 Space Conditioning System Location or Area Served Main
03 Building Type from CF-1R Single family
04 Verified Low Leakage Ducts in Conditioned Space No, credit is not taken
(VLLDCS) Credit from CF1R?
OS Verified Low Leakage Air Handling Unit (VLLAHU) Credit No, credit is not taken
from CFlR?
06 Duct System Compliance Category Alteration using smoke test
MCH-20e -Sealing All Accessible Leaks using Smoke Test
B. Duct Leakage Diagnostic Test
01 Condenser Nominal Cooling Capacity (ton) 4.0
02 Heating Capacity (kBtu/h) 80
03 Conditioned Floor Area served by this HVAC system (ft2) 2489
04 Duct Leakage Test Condition Test final
OS Duct Leakage Test Method Total leakage
06 Leakage Factor 0.1S
07 Air Handling Unit Airflow (AHUAirflow) Determination Heating system method
Method
08 Measured AHUAirflow 0.0
09 Calculated Target Allowable Duct Leakage Rate (cfm) 260
10 Actual duct leakage rate from leakage test measurement 3SS
(cfm)
Registration Number: 416-A0009319A-M2000002A-M20A Registration Date/Time: 2016-12-14 12:53:25 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2013 Residential Compliance
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.007
Report Generated: 2016-12-14 12:53:32
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 2 of 3)
B. Duct Leakage Diagnostic Test
Compliance Statement: System passes using smoke test of an altered HVAC system in an existing building. No visible smoke
exits the accessible portions of the duct system. Smoke is only emanating from air-handling unit (AHU) cabinet and non
11 accessible portions of the duct system. Note-Accessible is defined as having access thereto, but which first may require
removal or opening of access panels, doors, or moving similar obstructions. If access to the ducts requires an object to be
demolished or deconstructed then sealing of those ducts is not required
12 Notes:
C. Additional Requirements for Compliance
01 System was tested in its normal operation condition. No temporary taping allowed.
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
02 testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation
Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closed position during duct leakage testing.
03 All supply and return register boots were sealed to the drywall.
04 Building cavities were not used as plenums or platform returns in lieu of ducts.
OS If cloth backed tape was used it was covered with Mastic and draw bands.
06 All connection points between the air handler and the supply and return plenums are completely sealed.
If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements
07 of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample
groups for HERS verification compliance.
08 Verification Status: Pass-all applicable requirements are met
09 Correction Notes for this table:
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have
been met unless otherwise noted in the Verification Status and the Corrections Notes in this table.
D. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 I Complies: All specified verification protocol requirements on this document are met.
Registration Number: 416-A0009319A-M2000002A-M20A Registration Date/Time: 2016-12-14 12:53:25 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2013 Residential Compliance
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.007
Report Generated: 2016-12-14 12:53:32
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 3 of3)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Rodney Williams 'R.od.t1ey w~
Company: Date Signed:
We Green Inc. 2016-12-14
Address: CEA/ HERS Certification Identification (if applicable):
3645 Ruffin Road #330
City/State/Zip: Phone:
San Diego CA 92123 888-891-4377
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Verification is true and correct.
2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency.
5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/OWner):
ASI Hastings, Inc.
Responsible Builder or Installer Name:
Maria Baldwin
HERS Provider Data Registry Information
Sample Group Number (if applicable):
HERS Rater Information
HERS Rater Company Name:
We Green Inc.
Responsible Rater Name:
Rodney Williams
Responsible Rater Certification Number w/ this HERS Provider:
RCN13096
Registration Number: 416-A0009319A-M2000002A-M20A
CA Building Energy Efficiency Standards
2013 Residential Compliance
CSLB License:
513115
Dwelling Test Status in Sample Group (if applicable)
N/A
Responsible Rater Signature:
'R.od.t1ey w~
Date Signed:
2016-12-14
Digitally signed by CHEERSTM. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Date/Time: 2016-12-14 12:53:25 HERS Provider: CHEERS
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.007
Report Generated: 2016-12-14 12:53:32
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 1 of7)
Project Name: 2230 Vista La Nisa Enforcement Agency: City of Carlsbad Permit Number: CBR2016-0189
Dwelling Address: 2230 Vista La Nisa [Main] City: Carlsbad Zip Code:
A. General Information
01 Dwelling Unit Name Main 02 Climate Zone
03 Dwelling Unit Total Conditioned Floor 2489 04 Number of Space Conditioning
Area (ft2) Systems in this Dwelling Unit.
OS Certificate of Compliance Type Prescriptive alterations (CF1R-ALT) 06 Method used to Calculate HVAC Loads
07 Calculated Dwelling Unit Sensible 48 08 Calculated Dwelling Unit Heating Load
Cooling Load (Btuh) (Btu h)
09 Dwelling Unit Number of Bedrooms 4
MCH-Olb Space Conditioning Systems Ducts and Fans -Prescriptive Alterations
B. Space Conditioning (SC) System Information
01 02 03 04
SC System SC System CFA served Is the SC
Identification or Location or Area by this SC system a
Name Served System (ft2)
ducted
system?
System 1 Main 2489 Yes
Registration Number: 416-A0009319A-M0100001A-OOOO
CA Building Energy Efficiency Standards-2013 Residential Compliance
OS 06 07
Installing a Installing new SC Installing more refrigerant system than 40 feet of containing components? ducts? component?
Yes Yes No
Registration Date/Time: 2016-12-14 12:50:24
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
08
Installing
entirely new
duct system?
No
92009
7
1
NotApplicableEquipmentChangeout
80
09 10
Installing
entirely new SC Alteration Type
system?
Altered space
No conditioning
system
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:S0:31
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
C. Space Conditioning (SC) System Alterations Compliance Information
01 02 03 04 OS 06 07 08 09
Heating Cooling
System Altered Heating Minimum Altered Cooling Minimum
Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency
or Name System Type Component Type Value System Type Components Type Value
All new All new
System 1 Central gas heating AFUE 0.8 Central cooling SEER 14 furnace componen split AC
ts components
D. Installed Heating Equipment Information
01 02 03 04 OS
System Identification or Heating Efficiency Heating Unit Heating Unit
Name Heating Efficiency Type Value Manufacturer Model Number
System 1 AFUE 0.8 YORK TM8Y100C20MP1
1A
Notes:
- -
Registration Number: 416-A0009319A-M0100001A-OOOO Registration Date/Time: 2016-12-14 12:50:24
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
\.
CFZR-MCH-01-E
(Page 2 of7)
10 11 12 13
Central Fan
Integrated
New or (CFI)
Required Replaced New Ventilation
Thermostat Duct Duct System
Type Length R-Value Status
This
field
N/A-no or
Setback ducts sectio Not a CFI
replaced n is system
not
applic
able
I
06 07 '
Heating Unit serial Rated Heating Capacity,
number Output (BTUH)
Wlf6730100 80
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:50:31
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
E. Installed Cooling Equipment information
01 02 03 04 OS 06
Condenser or Package Unit
Condenser or Condenser or Condenser or
System Identification Cooling Efficiency Cooling Efficiency Package Unit Package Unit Package Unit
or Name Type Value
System 1 SEER 14.0
Notes:
F. Extension of Existing Duct System, Greater Than 40 Feet
G. Installed Duct System information
H. Installed Air Filter Device Information
I. Air Filter Device Requirements
Registration Number: 416-A0009319A-M0100001A-OOOO
CA Building Energy Efficiency Standards-2013 Residential Compliance
Manufacturer Model Number Serial Number
YORK CZH04812CA W1K6960184
This section does not apply to this project.
This section does not apply to this project.
This section does not apply to this project.
This section does not apply to this project.
Registration Date/Time: 2016-12-14 12:50:24
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
' , <
CF2R-MCH-Ol-E
(Page 3 of7)
07 08
System Rated Cooling Condenser Rated
Capacity at Design Nominal Capacity
Conditions (BTUH) (ton)
48 4.00
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:50:31
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
J. HERS Verification Requirements
01 02 03 04
MCH20
Exemption
System SCSystem From Duct Duct
Identification or Location or Area Leakage Leakage
Name Served Requirements Test
System 1 Main No Yes exemptions
Notes:
Registration Number: 416-A0009319A-M0100001A-OOOO
CA Building Energy Efficiency Standards-2013 Residential Compliance
OS 06 07
MCH21 MCH22
Exemption
from
Minimum
R-Value for
Ducts In Ducts Located AHU Fan
Conditioned In Cond Space Efficacy
Space Verification (W/cfm)
This field or
section is
not No No
applicable
Registration Date/Time: 2016-12-14 12:50:24
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
'
CF2R-MCH-01-E
(Page 4 of 7)
08 09 10
MCH23 MCH25 MCH28
AHU
Airflow
Rate Refrigerant Return Duct Design
(cfm/ton) Charge Table 150.0-C or D
No No No
•
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:50:31
'
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b).
03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections
150.0(h)1 and 2).
04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum
inlet-to-outlet temperature rise specification. See Section 150.0(h)4.
OS Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d).
Cooling Equipment
I
06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
I Regulations.
07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 1
150.0(j)2 and 3, and Section 150.0(m)9.
08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A.
09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section
150.0(h)1 and 2.
Air Distribution System Ducts, Plenums and Fans
10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
required by the prescriptive or performance requirements. See Section 150.0(m)1.
Registration Number: 416-A0009319A-M0100001A-OOOO
CA Building Energy Efficiency Standards-2013 Residential Compliance
---
Registration Date/Time: 2016-12-14 12:50:24
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
---
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:50:31
' i
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 6 of7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
11 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
13 The thermostat shall be installed in accordance with the manufacturers published installation specifications
14 First stage of heating shall be assigned to heat pump heating.
15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met.
The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 416-A0009319A-M0100001A-OOOO
CA Building Energy Efficiency Standards-2013 Residential Compliance
--------
Registration Date/Time: 2016-12-14 12:S0:24
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
----··-----
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:S0:31
' ..
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 7 of7)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Maria Baldwin ~ a¥U;;v BcUdMJ i¥\1
Company: Signature Date:
ASI Hastings, Inc. 2016-12-14
Address: CEA/ HERS Certification Identification (if applicable):
4870 Viewridge Avenue #200
City/State/Zip: Phone:
San Diego CA 92123 800-481-2665
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer). otherwise I am an
authorized representative of the responsible builder/installer.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the
installation conforms to the requirements given on the plans and specifications approved by the enforcement agency.
4. I reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of
Installation, and I have ensured that the requirements that apply to the construction or installation have been met.
5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all
applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Maria Baldwin
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
ASI Hastings, Inc.
Address:
4870 Viewridge Avenue #200
City/State/Zip:
San Diego CA 92123
--------~~---
Registration Number: 416-A0009319A-M0100001A-OOOO
CA Building Energy Efficiency Standards-2013 Residential Compliance
Responsible Builder/Installer Signature:
lv!a¥U;;v BcUdMJ i¥\1
Position With Company (Title):
Contractor/Installer
CSLB License:
513115
Phone: I Date Signed:
800-481-2665 2016-12-14
Digitally signed by CHEERSTM. This digital signature is provided in order
to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Date/Time: 2016-12-14 12:50:24
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
HERS Provider: CHEERS
Report Generated: 2016-12-14 12:50:31
' .~