HomeMy WebLinkAbout2232 RUTHERFORD RD; ; CB012991; Permit11-06-2001 ,
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
09/27/2001
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB012991
Building Inspection Request Line (760) 602-2725
2232 RUTHERFORD RD CBAD
Tl Sub Type:
2120612600 Lot#:
$5,000.00 Construction Type:
Reference #:
BIOTA -LOCKIN~ HARDWARE
COMM
0
NEW
Status:
Applied:
Entered By:
Issued:
Inspect Area:
ISSUED
09/17/2001
JM
Plan Approved:
11/06/2001
Applicant: Owner:
SDA S M/C T RESEARCH CENTER I L.C
C/0 DELOITTE & TOUCHE J?t/2 J.1/06/01 0002 O.:l. 02
2054 STATE STREET
SAN DIEGO CA 92101
?19-338-1290
PO BOX 130174 CGP• 82-21}
CARLSBAD CA 92013
f '
Total Fees: $'122.01
· Building Permit
Add'I Building Permit Fee
Plan ·Check.
Add'I Plan Check Fee
Plan Check Discount
· Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD-#2 Fee
BTD#3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Total Payments To Date: $39.77 Balance Due:
$61.19
$0.00
$39.77
$0.00
$0.00
$1.05
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF
PFF (CFD Fund)
License Tax
License Ta_x (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund)
PLUMBING TOTAL
ELECTRICAL TOT AL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOTAL PERMIT FEES
$82.24
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$20.00
$0.00
$0.00
$0.00
$0.00
$0.00
$122.01
FINAL APPROVAL
Date: <#fk Clearance: _____ _
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have · reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
~u
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Farapay Ave., Carlsbad, CA 92008
Validated By___.:~L::...-L--6~Y'-~~--
Date. ________ ...,q.-1-...£,,-..::=-,. __
Business Name (at this adi:lress)
Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
Assessor's Parcel # Existing Use
~~~os~Ji~/01 0002 01 02
# of Bedrooms , CGIFM Bathrooms 39. 77
~;~i·~1'f~:F~Ag~%~~;~:~_g9(:.;~Qst}¥;::ip~~2~(gr~¥7~:=o:~i~~,~~~~171'Pi1ro
Name City
Ii3YlioP,ER#iov:m~!;; :~:_-: ___ ; ~:,.;_:;_:: '.~::< ,_,:-.":~:~·~,: .:
Name Address City State/Zip Telephone#
r~_.,;",~co.rtmc1to1t~:t1Ql"IJ000::NA~.e::::::-, .. "-·· :. ':: •. _ ~, ... =_ ..... __ ..... _-:-.-,. -,. ... ~--.~--.-. ::.::;:;::r::;;::~::;:;:;.;::12;;,,:,,;;,,,.,.;,;,-,s.,;;.,,""''-
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions, Code] or that he is exempt therefrom, and the basis for the alleged
exemption·. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to-a civil penalty of not m re than five hundfjd dol ars [$50CH)} .1 9 -J1 J'cc.u I ,I j lf.::.'t,ttJ db r I~ • ,J 1.::.'60 C .o/ Jo vl"i ~ -(0, D
Name'\U·.c! I \7 Address I'\? t!to Al-City . State/ ip ·"' s Tele hone#
State License # __.r:t."'-r"-"-"}_"-'fa~fP"-'d_.,_____ License Class l-{V L C City Business License # J-, l 0
Designer' Name Address City State/Zip Telephone
State License # --~-------
!§~,: .. -..W.Qf:IK!IR~f::<;9.MP~N,S.~ TJQ:tf, ·;, ·.: .:,,,-: ,~, "'· .. -, -. -_-_ .'., ,,:;.:,; ,, ~~-:~. ;.: : -~L _.., ::~,,~;,,,, ...... ,.;,..,:,J,·,::.-.::"':1.,,~.·-::::::::.":·;:~ .. ,',:.:.L,~.-;t-::Ll }~:.J:'.1~?:.~~~
Workers' Compensation Declaration: I hereby affirm under pe11alty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
[if' I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compe~saiion insurance_c~rier a'!,d policy ~mber are: , . , • 00 / /
Insurance Company /tltl.:.'/ltC.~ A"tt/1.f6c/lV.:.' J.,JJ_ lo, PolicyNo.J0AJi;JCOOO '/ft/1) Expiration Date/ [IOJ
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject·to the Workers' Compensation Laws of California.
WARNING: Failure to ompensation coverage is unlawful, and shall subject an employer to ~riminal penalties and civil fines up to one hundred
thousand dollars ($10 o the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE • DATE t:J /rJ/6 J .
f7;':!:6WNER~a01bo'Eifo1:cliAFiAtt 't{ · .. -_: ,·· :":'· ·: ;··, ". _-:· ·-·:: ~:2:'\:{·,_·-~;::~_:, e~z:,··t.;;-:~,,·::/:·:z, :~:'l,;;::,~:--:,q;,7;:~£::~tt/1>.:.,'?i:>
I here~y affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do 'the work and the structure is not intended or offered for sale
· (Sec. 7044, Business ,and Professions Code: The Contractor's License Law does not apply to an ·owner of property who builds or improves thereon, and who does
such work hiniself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of cqmpletion, the owner-builder will have the burden of proving that he did not build or improve ·for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for ·such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ------Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property·improvement. 0 YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted, with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. ,1 plan to provide ,portions of the work, but I have hired the following, person to, coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _
5. I will' provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):. ___________________ .,__ ____ ~~----------------~--------------
PROPERTY OWNER SIGNATURE______________________ DATE ________ -'--
i9..QMP(~1ifl!~,~t9J!Qiff9,Jj/lQ!Mf§1Psl{:fM~-~Y!!;QW,!(~Em}fj;gJf~__:~:-:::'.'::t:-;t:~E:f;:JT:\'::·,~~::l'.82~§;~~;{;;'.:,'";ff[::;;g_;;I;_'.:::-:;;,'.~:;:.:I'(
Is the applicant or future building occupant required to submit a business ·plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
!~..::~:::...cQt:l~TflJl.~TIQN~te~:P.1N,~~q~1J.W ...
!'hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec, 3097(i) Civil Code).
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction, I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT,
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become· null and void if the building or work
authorized by such permit is not commenced within 180 days from-the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at.any time after the work is comme 5ed ior a p ri ~ 80 days (Section 106.4.4 0niform Building Code).
APPtlCANT'S SIGNATURE _ _.,L..:~:=.~.y..~~=---------------DATE __ <j~/_l_?~/_C>_/ _____ _
YELLOW: Applicant PINK: Finance
/
City of Carlsbad Bldg Inspection Request
For: 11/15/2.001
Permit# CB012991
Title: BIOTA· LOCKING .HARDWARE
Description:
Type: Tl Sub Type: COM~
Job Address:. 2232 RUTHERFORD RD
Suite: Lot O
Location:
APPLICANT SDA
Owner:
Remarks: LOCKING HRDWRE
Total Time:
-. , . :
., ... ~. : ... ; . ~ · .... ,
CD Description Act Comrner:its
39
Date
Final Electrical
Associated PCRs
PCR01287 PENDING
Inspection History
,. ,,,_ .,'.·
Description Act lnsp Comments
Inspector Assignment:
Phone: 7605212640
Inspector: .£2_
Requested By: MIKE . .
I c.· • '
: : :· Entered By: ROBIN
EsGil Corporation
In Partnership with Government for Building Safety
DATE: 9/26/01"
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 01-2991
PROJECT ADDRESS: 2232 Rutherford Rd
SET:I
PROJECT NAME: Biota Inc -Controlled Access Hardware
D~t-JT
~
D PLAN REVIEWER
D FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's b1:1ilding codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check-list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until correct~d plans are stibmitted for recheck. ·
D-The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D . The applicant's copy of the check list has been sent to:
[g] Esgir Corporation staff diet not ~dvise the applicant that the plan che·ck has been completed.
D Esgil Corporation staff did advise the applicant that the_ plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
D REMARKS:
By: Doug Moody Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 911 e101 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 01-2991
9/26/01
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: Doug Moody .
PLAN CHECK NO.: 01-2991
DATE: 9/26/01
BUILDING ADDRESS: 2232 Rutherford Rd
BUILDING ·OCCUPANCY: B TYPE OF CONSTRUCTION: VN
BUILDING AREA Valuation Reg. VALUE
PORTION ( Sq. Ft.) Multiplier Mod.
Access Hardware NIA City Valuation
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1994 l.JBC Building Permit Fee j ... j
1994 USC Plan Check Fee / ... /
Type of Review: 0 Complete Review . D Structural Only
D Repetitive Fee ~ Repeats
Cor:nments:
D Other
D Hoµrly ...._ ___ __.I Hour*
Esgll Plan Review Fee
. ($)
5,000
5,000
$61.19j
$39.771
$34.271
Sheet 1 of 1
macvalue.doc
\
Carlsbad Fire Department 012991
1635 Faraday Ave.
Carlsbad, CA 92008
,Plan Review Requirements Category:
Fire Prevention
(760) 602-4660
Date of Report: _1_01_04_12_0_0_1 _________ _,..
Building Plan
Reviewed by:
Name: SDA Security Systems
Address: 2054 State Street
City, State: San Diego CA 92101
Plan Checker: Job #: 012991 · -------
Job Name: Biota, Inc. Bldg #: Cb012991 --------------------
Job Address: 2232 Rutherford Rd Ste. or Bldg. No.
IZl Approved
LI Approved
Subject to
LI Incomplete
Review
· FD Job#
The item you have submitted for review has been approved. The approval is
based on plans, information and/ or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply.with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or spedfications to this
office for review and approval.
1st
012991
2nd
FD File#
3rd ·----Other Agency ID
•• . .-. ' 1 -BIOTA,INC.
2232 RUTHERFORD ROAD
Carlsbad, CA. 92008
Security Lo~king Hardware Submittal
Submitted By;
SDA Security Systems, Inc.
Contact: Paul Stanzione
2054 StfJte Street
San Diego, CA 92101-1780
License#245668/Type C7,Cl0
• BIOTA,INC.
Security Locking Hardware Submittal
Equipment List
Description Model#
Control Panel Northern N-750
Card Reader Northern PR-MINI-PROX
Touch Sense Bar Adatlls Rite 8611-EL
Rim Strike Adams Rite# 8801-EL-36 • Mecanical Push Bar Adams Rite# 8611-36
Power Supply Adams Rite # 29-01-04
•
• N-750 Access Control / Burglar Panel
' . '. ",:' " ' .,, , ,-. ~ ', . : . , ,'· '
• ·F1eiib:1,i:~_in:f.t~~htfii~~l1 :>iB ·. ·. ·ett~e'thienes$. :!n~ke.s .. :ihe=i :'..i
. '.,:··· :i}~~,~~tiJ:i";tii:
..... _. Th~ ;N~750' 6ff~r~c: ·· · ·.: ,· · , '?i? llll!!!llf'/' . . '. . '• ' ' ' . . ,: , • ~' • I ' ; • • '. ' ,,._ ~ ~ :',
:st~n~~al:one :se'~utity -Qt.
seamless, :i'ntegrat;,omiWith · .access ·idr:1irot ·. :· :. , · · · i·
.... /t·/: .. ;>;_. >?\::·:xtrr.:\
J•:::.fQr.Jn~iJi~tehanx·bu'.ll'd~/ ..
_ -, Jngs, en.e ;N~75o installa-T :
. ' ti'or:1.~ ~-ao,;~e :part'i'ticir1ed )c(: ,._ i; ., 1
~:~!ilf!f j]fITfli?
:~ '":? "softiticin/tc{serv,ce?1ra:undreas::J
• <; ·: ;:: \~f'.:i,;etl~l';~~-~riduih::t9,.t~,~r/:)?~
· :· N~t$e>Jor..:·~~~t9m,~ed :tJ,rie:? !· :]
·. , sdf:1edlli1es':,anc( user ¥>rofilfis.': :
:,__;j~:i~~ig~J\t~~loici~,; .. ;~i,· ••...
i_\ . ., · · .: N;,;1so.::cani:=re ort:,tacH it ,:ift1:r\ ;:¾ , .. '. : ,·,. · : . ; ·:,>_-,, :;:_::'·, ·P.i :;:,· ·: .. ,1, -: l)-..<r,_;;;J ).J ..... ;c:;-c,per$,onr;i~1,.~pt1v1ty,::~y:ster,11" ':· :-:;,:,
.,)}lrf!~~~trr~@~,~~"ft!~!f til
. • ±+iir~~~~;.~~*G~i~~i~:ii~j . . , $Y~,~m.~.tatl!l$i w1tli co.m. -., .... /--·.\·,
'~ •' '-,, -. • ' •' ~ ; • < O ,_. ~· t .; : .,. > ;' ' , • Jr • '<' '-, ,., • ,._ .. ,, :':.'t P,Jete 0• easYi-tb~.un:derstan~f1~:. ·:~;tl
•. ··;;.\t~~t1j1!;{i;t:,:-;itiIJt[f [lM 41t: .. §u1gJ.e .. fu°-cH.on .l(eys .a.t \·, ,t .•. : .. ,. :·i
· c : ··:t~µ¢tJ:p.acf~tati.e>.ris _ellmJnai~r ·:/
: .. i i\·. t~~c ne~.d'. .!~r_c~9~J1J'.e:~.-~~t~,,;:;:;
. ·. :·,:til?h._or-multi~:st~P':C:>.p;er,atJ~:As~ :·., e : >i ·er >·t ... ·. : ;<}{{W~l'J
~ ·· .• •. 71&;-JJJ;flaflt~;;t:~-1
I ·: -/ :·::· :i:~~:95Jl~~~t4~~~1ii~j~j
The basic configuration options of the N-750 center around
four simple features. These four simple features are building
· blocks engineered for complete flexibility, so a system can be
tailor"made for your application.
Security Points. -A security point is simply a single point of
protection. For your security needs it might be a contact switch
on a window or a motion detector, or even the lock control on
a door. And with addressable points, the activity and condition
of individual security points can be identified.
Zones -A zone is one or more security points grouped
together rn an electrical circuit. For example, the doors,
windows and.other security points in a conference room could
be identified as a specific zone .
Ar~as -An area can either be classified by a group of security
points, or by one or more zones. You can control your areas
individually as well as grouping them together.
Partitions -The N-750 brings you true partitioning in a
single system. A partition is an area or group of areas config-
ured into an autonomous system. For example, a management
company for a high-rise can invest in one N-750 system to
provide individually programmed, monitored and billed access
control and security services to each of its tenants. In this type
of environment, the cost savings, maintenance and reliability
of the N-750 is years ahead of any other technology. What
used to take a number of systems, multiple vendors, and a
variety of service and monitoring contracts, now can be
handled with one system from one company.
5007 South Howell Ave. tel: (414) 769-5980
Milwaukee, WI 53207 fax: (414) 769-5989
web site:
http://www.nciaccess.com
Access Control/ Burglar Panel N-750
SBUS 1
&SBUS2
N-750
N-750-PAIT
01-1 ttttt:
N-750-ADM ·
Monitor Contact/ Door Zone
AC)j28,32or34blt TQUCHPADS/
egand Reader CARD READERS
Reader (max. 24 per systt;!m)
ZONE
EXPANDERS
Any 28, 32 or 34 bit : Wlega~d Reader
N-750-SSE N,-750-ZONE
[] AND/OR _
Adda 128 Zon11 Addi 84 Hardwired Zones
U11 with N-7150-SS ti max, Smart S11ri1or1
3max.
UL Listings
• UL 294 Access Control
• ULGradeA
• UL 365 Police Connect
• UL 609 Local Burglary
• UL 611 C.S. Burglary
·-:,
• UL 636 Holdup Alarm Units
• UL 681 Bank Bur~lar Syste.\ PRINTER
Features
CPU for direct connection
to ACAS Software • UL 864 Comm. Fire C.S. ,. ·
• UL 985 Household Burglary
• UL 1023 Household Burglary
• 16 supervised programmable zones,
expandable to 400.
• Up to 24 touchpads and/or card readers. • UL 1076 Proprietary Burglary
• 50 time schedules with 20 ranges per • UL 1610 C.S. Burglary
• Eight true partitions with up to eight areas
per partition (64 possible areas).
schedule. · · • • Uh 1635 Digita!Burglary System
• Up to 1,800 users or cards.
• High speed RS-485 bus to.connect
touchpads, zone expanders and other
accessories.
Panel Specifications
Dimensions ....... 15"W x 20"H x 3"0
Weight ............... 17 lbs.
Power ................ tBVAC, 60Hz, SOVA
Temperature ...... 32° to 120° F
0° to 49° C
Humidity ............ 85% non-condensing
-~-Jjjmt,-
1-800-323-4576
• Auto or manual lock/unlock.
• Local and Global anti-passback.
• Duress feature.
Ordering
N-750 ................. Security/Access Control Panel
N-750-PAIT ........ Programming & Access
:rouchpad for the N-750
N-750-ADM ........ Door Access Module for the
N-750
N-150-PI ............. SerlaVParallel Interface.for
·Printer or Direct Connect to
N-750
N-750-ACAS ...... Administration Software for
theN-750
N-750-SK ........... Remote Upload/Download
Software for the N-750
• ULC Res./Comm. Burglary
• FCC Part 15
• FCC Part 68
• DOCCS-03
• CSFM Res./Comm/Fire
N-750-APS ......... 12VDC Auxiliary Power
· Supply for the N-750
N-750-APS-24 .... 24VDC Auxiliary Power
Supply for the N-750
N-750-ZONE ...... 64 Zone Expander for the
N-750
N-750-SS ........... Smart-Sensor for the N-750 &
N-750-SSE
N-750-SSE ......... 128 Point Expander for the
N-750
N-750-DPLM ...... Dual Phone Line Module for
the N-750
· · N-750-f!ELL ....... Bell Supervision for the N-750
5007 South Howell Ave.
Milwaukee, WI 53207
tel: (414) 769-5980
fax: (414) 769-5989
web site,
http://www.nciaccess.com
·-
. ·. . ,t
.. POOR
. -
· QUALITY
;. . ! ( j-: . r" .;: ! .
· · O'RIGINAL S
. .
. . . .:': .. -. z·
••
•
Also available
for a Midpanel
door design
CERTIFICATIONS:.
@Life-Safety Listing
ANSI/BHM-\Al56.3 Grade l
California State Fire Marshall
Nevv York City MEA*
•c;oruu1t ~ for ~fie '1\Jtnber
~ ADAMS RITE
~ MANUFACTU:RING CO.
BHMA TYPE 6
Narrow Stile
Concealed Vertical
Rod Exit Device
8600 Series
LJFE-SAFETY
0
T Patented top latching
mechanism interlocks door
to frame
T Top and bottom adjustable
steel rods
T Pushbar clad, not plated, in
a variety of finishes
T Easy to install
T Clean, unobtrusive design
· T Strong, durable construction
for a high level of security
260 Santa Fe Street
P0mona, California 917 6 7
(800) 872-3267 Fax:(8OO) 232-7329
www.adamsrite.com
Narrow Stile Concealed Vertlcal Rod Exit Device
ANSIIBHMA
Grade I
Handing
Device is non-handed. Lever Entry
Trim is field reversible.
Pushbar Length
Standard Sizes: Dimensioned for 30',
36', 42' & 48'openings. Standard
width bars can be field cut to the
next smallest opening width.
Projection
2-5/8' when fully projected,
Js5/8' when dogged.
Door Thickness
Suits 1-3/4' standard, up to 2-1/4'.
Device requires modification when
used with cylinder in doors over 1-3/4".
Stile Wall
Doors-with stile walls other than I /8'
require modification.
Stile Width
Minimum 2' Stile. Fits Narrow, Medium
and Wide Stile aluminum doors.
Bar Height
Adjustable from 30" to 44'.
Door Height
Standard unit adjustable for doors up to 66'
above the selected bar·height. For doors
over 66 • above .bar height, up to IO', use
8655 Tall Door Kit.
Materials
Pushbar made of extruded aluminum, clad
or anodized in a variety of finishes.
Dogging
Standard dogging with hex key or optional
cylinder dogging. Electric dogging available.
Fasteners
Standard self-tapping screws.
Strike
Made of hardened steel. Supplied.
Cylinders I order separately)
Cylinder x Fixed Pull:
{Function 03)
Accepts any standard Mortise cylinder with
Ms• cam.
~ntry Lever or Thu.mbturn: (Functions 08, 09, 11, 12)
Accepts any standard diameter Mortise
cylinder with MS•·cam. Accommodates
cylinder lengths from I' to 1-1/4".
Warranty
Two year limited.
AVAILABLE FINISHES
313 Dark Bronze Anodized
335 Black Anodized
628 Satin Aluminum
US3 Bright Brass
US4 Satin Brass
US9 Bright Bronze
US10 Satin Bronze
10B "Oil-Rubbed" Bronze
(frim only/
US32 Bright Stainless
US32D Satin Stainless
Consult factory for special tfnishes.
Bolts and Strikes Pushbar Dimensions
Bottom
Bolt
The patented top latching
mechanism utilizes a rotating
Top Bolt which deadlatches
around the Header Strike,
interlocking the door to the
frame.
Supplied with Standard or Fire-
rated Header Strikes.
The hexagonal, hardened steel
Bottom Bolt works in harmony
with the Top Bolt
Standard
Strike
Fire-Rated
Strike
Fully Projected
8675
Mldpanel
0
Dogged
The Concealed Vertical Rod exit device is also available
for use with a Mldpanel
design. Consult factory for
applications.
•
•
•
•
Narrow Stile Concealed Vertical Rod Exit Device
Order by adding sulllx to Exit Devlee In plaee oi hyphen or by separate model number.
MONITOR/SIGNAL SWITCH
M 1 • Single SWltch
MZ -Dual SWltch
A switch in ttte ·exit device pushbar
mountea on the hinge end.
Switch can be used to activate
signal light horn, monitor or:other
devi'ces. Most common
applicatioh is to release maglock
when pushbar is depressed.
Switch can be Wired for nonnally
open or nonnally clo~d depending upon applicatioo. can be
retrofit 'in ,field to existi,ng exit device. Dual switch version offers
~dundancy as required by some building codes or the optjon of
operating a second signaling device.
Specify by,adding "Mt"or "M~" after exit device model number.
Mof'!ltor.KitS for upgradfng any 3000 or 8000 Series device:
91-0897-01 • Single Switch 91-0897-02 • Dual Switch
The EL option uses a
solenoid mounted in
pushbar for instantaneous
unlocking and locking of the exit
device from a remote location or access
control device. Because electrical operation
of devic~ is fail-5ecure, this option can be used on
fi~ated as well-as life.safety applications. In the event
of a power failure device automatically relatches. Requires
the use of 29-0 I 04 Power Supply, which Will power two exit devices.
Specify by adding '\EL" after exit device model number. Order
29-0104 Power Supply separately.
Solenoid Specifications:
24VDC -12 Amps lnrush/.12 Amps Hold
Solenoids are rated for both intermittent arid continuous operation.
Also see 4611 Power Transfer.
MONITORED DUMMY PUSHBAR
S099M1 -single Switch
8099M2 • Dual Switch
8099-00 • Duinmy Only
Dummy pushbar with no latch mechanism but With eithe-: a single
. or dual nionitqr/signal sWitch. Most common application is in
conjunction with a m~lock wh~bar is used to turn off magnet.
and allow exit from building. Dual switch version allows redu,nqqncy
where required by code or the operation of a signal device along ·
with magtock. Specify door type and Width when ordeflng.
Available in all exit device finishes .
The 8099-00 is also available as a non-operating dummy fof doors
not requiring an exit deice; but where mat~hlng trim is desired,
Specify door type, opening width and finish to berriatched,
000710 8600 02000JIOYdS,RlfE M'\Nt,/f;f,CJ'UG CO.
ALARMED EXIT DEVICE
This option emits a loud alarm to notify management of
unautliorized exit Will not alter the Life-Safety characteristics of the
exit device in any way. Control of the alarm is by use of a key in any
standard Mortise cylir,der with Mse cam to ann, disann, delay or
reset the alann. 'Red letters on the bar give a "hands off' warning to
deter.accidental actuation.
S.ttery Operated Alarm
Four M alkaline batten~ power tWin horns to create a piercing 95
decibel noise for two minutes (or until disarmedJ when push bar is
depressed. Beeps to signal need fornew batteries.
Hardwired ~arm
.can be connected to external horn for louder or remote signal.
Remote monitor LED light can also be wired in, as can a door
position proximity switch. Also accommodates an external delay
switch, such as an outside key switch or pad, to allow authorized
entty. Uses rechargeable nicad batteries connected to 12-24 Volt
AC or DC souree. Each bar has its own battery backup system.
Minimum opening width: 36"
CYLINDER DOGGING
:--a:~ ~~~Ices mr::=ID@
'For management control of • . .
dogging. Any standard •
15'/16" to 1-1/8" long
Mortise-cylinder with MSe cam can be used in a pushbar prepared at
facto,y with Cylinder Dogging kit. Cannot be used with Alarm or EL
option.
Specify by adding ·co· after exit device model number.
ELECTRIC DOGGING
For all Adams Rite
Exit Devices
The "ED" option uses a
·holding magnet to
k~ep the pushbar
depressed and ,the
latch, open. This gives a lower profile exit device, resulting in Jess
d~mage, It also rest:Jlts in more quiet operation. On fire-rated devices,
,it mu~t 'be wired through the fire alarm system. All devices are
available in 24VOC, draWing .5 amp, allowing them to operate with a
simple transformer and rectifier. The "EDM", which indudes a
mlcroswitch in.the pushbar: is ideal for use with automatic operators
when security is not an issue. (Use ·a· with security devices such as
card reader or keyswitches.J
Specify by adding "ED" or "EDM" after exit device model number.
-,~ ....... _.:
Narrow Stile Concealed Vertical Rod Exit Device
ANSI/BHMA Functions:
01 02 03 08 09 11 12 14
PULL ONLY KEY RE1'MCIS WHEN DOGGED lATCHIIOU'
EXQ' m ONL'I-FIXED PULLS FIXED PULLS N011HM BYOTHE~S BY OTHERS
NIA NIA MORNQ))
r-s.oo
Modem Model 3081
Thumbturn
0
Model 8066
i<EYLOCICS LEVD
CYLINDER TYPE
MOR1'1SE MOR1'1SE
QI) (;I)
Clutch Lever Entry Trim
Tubular Model 3082
Mortise Cflinder
Standard diameter five-pin unit with
Ms9 cam, suitable for use with Ent:Jy
. Trim on Rim exit devices. All brass
construction with front ·scalp"
available in finishes 628,313,335,605
and 612. Available in quantity all keyed
different (KD), in pairs (KA2J·o,:fifty alike
(~O). Any other make standard
Mortise cylinder with MS• cam can be
\JSed to "key In" with existing ~enis.
MOR1'1SE MORTISE ~ ~ NIA
m:I -Night Latch
'D'adltlonal Model 3083
Escutcheon
BI~ l-1.75 -I --14-
8650
Required to mount any make standard
Mortise cylinder, with Ms• cam, on
outside of door. Specify finish being
matched when ordering.
•
•
•
•
CER11FICATIONS:
@Ufe--Saf~ty Listing
ANSI/.BHt#\Al56.3 Grade I
California State Fire Marshall
New YorR City MrA*
•consult factoly fOf' specific num.ber
...l!/!A.;, ADAMS RITE . 'y"' MANUFACTURING CO.
0
BHMA TYPE 4
Narrow Stile
Rim Exit Device
For Aluminum Doors
8800 Series
UFE-SAFETY
Features:
T Patented "Starwheel" Bolt
interlocks door to frame
T Pushbar is anodized or ·clad, not
plated, in a variety of finishes
T Easy to install
T Unobtrusive design for clean
sight lines
T Strong, durable construction
for a high level of security
260 Santa Fe Street
Pomona. California 917 6 7
(800) 872-3267 Fax:{800) 232-7329
www.adamsrite.com
ANSI/BHMA
Gradel
Handl~g
Device is non-handed. Lever Entry
Trim is field reversible.
Pushbar Length
Pushbar Length
Standard Sizes: Dimensioned for 30",
36", 42" & 48" openings. Standard
width bars can be field cut to the
next smallest opening width.
Door Thickness
Suits 1-3/4" standard, up to 2-l/4".
Stile Width
Minimum 2· Stile. Fits Narrow, Medium
and Wide Stile aluminum doors.
Projection
2-5/8" when fully projected, l-5/8"
when dogged. ·
Materials
Pushbar made of extruded aluminum,
clad or anodized in a variety of finishes.
Starwheel Bolt
.Narrow Stile Rim Exit Device
Dogging
Standard dogging with hex key or
optional cylinder dogging. Electric
dogging also available.
AVAILABLE FINISHES
Fasteners
Standard self-tapping screws.
Strike
Made of harder:ied steel. Star:idard and
narrow version supplied with exit device.
Cylinders (order s~parately)
Cylinder x Fixed Pull:
(Functions 03)
Accepts.any standard Rim cylinder.
Entry Lever or Thumbtum:
(Functions 08, 09, 11, 12)
Accepts any standard diameter Mortise
cylinder with Ms• cam. Accommodates
cylinder lengths from 1· to 1-1/4".
313
335
628
US3
US4
US9
US10
10B
US3Z
US3ZD
Dark Bronze .Anodized
Black .Anodized
satin Aluminum
Bright Brass
satin Brass
Bright Bronze
satin Bronze
"Oil-Rubbed" Bronze
[frim only)
Bright Stainless
satin Stainless
Warranty
Two year limited. Consult factory for special finishes.
Pushbar Dimensions
~2-5/8
T· 2-7/16 --=iccl
_l____,•
f 1·] \ICltlen door closes, the interlocking noseguard and Starwheel bolt close
around the strike. The deadlocking slide springs over, locking the Starwheel bolt
to the strike. f2J When-push bar is depressed, the deadlocking slide moves back,
allowing the door to unlock from the strike. This unique intei1ock provides ,solid
security and prevents jamb spreading.
Fully Projected Dogged
Removable Mullion • 3890
Allows the use of Rim exit devices on paired doors
without narrowing the doors. Provides higher
security and better traffic flow than paired doors with
Vertical Rod exit devices. Ava!fable ln anodized 313
and 628. Specify door height when ordering.
Strikes
Standard strike and narrow
version for centering doors in 4"jamb.
•-
•
•
Narrow Stlle Rim -Exit Device
Order by adding sulllx to Exft.Devlce In place of hyphen or by sep;,rate model number.
MONITOR/SIGNAL SWITCH
M, • Single Switch
MZ • Dual SWltch
A switch fnthe exit device pushbar
mounted on the hinge end.,
Switch can be used to activate
signal light, horn, monitor or other
devices. Most common
application is to release maglock
When pushbar is depressed.
Switch can ~ wired for nonnally
open or nonnally clo~ed depending upon application. Can be
retrofit in field to existing exit device. Dual switch V(;!rsion offers
redundancy as required by some ·building codes or the option of
operating a seconq signaling device.
Specify by adding "Mror "Mr after exit device modeJ number.
Monitor Kits for upgrading any 3000 or 8000 Series device:
91-0897-01 -Single Switch 91-0897-02 • Dual Switch
The EL option uses a
solenoid mounted in
pushbar for instantaneous
. unlocking and locking of the exit
device from a remote location · or
access control device. Because electrical
operation of device is failcsecure, this option
can be used on fire;ated as well ,as lif~ety
applications. In the event of a power failure devic·e
automatically relocks. Rim devices are available in 12 or 24 VDC and
can be powered with a simple transfonner and rectifier or otherDC
power supply.
Specify by adding "~L" after exit device model number. Also
~peclfy 12 or 24 volt.
Solenoid S~ns:
EL-12 voe -l.03Amps Inrush/Hold
EL~24 VDC -.53 Amps Inrush/Hold
Solenoids are rated for both intermittent and continuous operation. s~ for optional hex key dogging. Also see 4611 Power Transfer.
MONITORED DUMMY PUSHBAR
8099M1 • Slngle Switch
8099M2 • Dual Switch
8099-00 -Dummy Only
Dummy pushbar with no latdl mechanism but with either a single
or dual monitor/signal switch. Most common application is iri
conjunct/on with a maglock where bar is used to turn off rnagn_et
and allow exit from building. Dual switch version allows redundancy
where required by code or the operation of a signal device along
with maglock. Sµ!;!Cify door type and width when ·ordering.
Available in all exitdevice finishes .
The 8099,-00 is also available as· a non-operating dummy for doqr..
not requiring an exit deice, l;>ut where matching trim is de$fred.
Specify door type, opening width and finish to be matched.
000710 8800 02000 N:W.IS RITE ~G CO.
·'·:'.-.
ALARMED EXIT DEVICE
This option emits a loud alarm to notify management of
unauthorized exit. Will not after the0Life-Safety characteristics of the
exit device.in any way. Control of the alarm is by use of a key in any
standard Mortise cylinder with MSe cam to ann, disann, delay or
reset the alann: Re9 letters on the bar give a "hands off" warning to
det~r ac:cidental-actuatlon.
Battery Operated Alarm
Four M alkaline l;>attenes power twin horns to create a piercing 95
qeclbel noise fbr two minutes (or until disarmed) when pushbar is
depressed. Beeps to sigoaf'need for nf!MI batteries.
Hardwired Alarm
Can· be connected to externpl horn for louder or remote signal.
Remote monitor LED fight can also be wired in, as can a door
position proximit;y .switch. Also accommodates an external delay
switch, such as an outside key switch or pad, to allow authorized
entiy. Uses rechargeable nicad batteries connected to 12-24 Volt
AC or DC source. Each bar has its own battery backup system.
Minimum opening width: 36"
CYLINDER DOGGING
Forcall non-rated Adams Rite EXlt.Devlces
For management control of
d9ggh1g. Any standard IS/16" to 1-1/8" long
Morose cylinder with MS8 cam can be used in a pushbar prepared at
facto,y wltt! Cylinder Dogging kit. cannot be used with Alann or EL
option.
Specify by adding ·co· after exit device model number.
ELECTRIC DOGGING
For all Adams Rite
EXltDevlces
The "ED!' option uses a
holding magnet to
keep the pushbar
depres~ed and the
latch open. This gives a lower profile exit device, resulting in less
damage. Ii: also·results in more quiet operation. On fire-rated devices.
it must be _wired through the fire alarm system. All devices are
available.in 24VDC. drawing .5 amp, allowing them to operate with a
simple. transformer and rectifier. The "EDM". which includes a
microswitch in the pushbar. is ideal for use with automatic operators
when security is not an issue. (Use "EL" with security devices such as
card reader or key switches.)
Specify by adding ·Eo· or "EDM· after exit device model number.
, -'. ' ~. j
Narrow Stile Rim E~it Device
ANSI/BHMA Functions:
01 02 03 08 09 11 12 14
PUU.ONLY
WHE,. DOGGED KEY REl1tACTS LATCHBOLT
EXIT m :~-M FIXED PULLS FIXED PULLS
NIA
BY OTHERS BY OTHERS
NIA ~
j---5.00
l
Modern Model 3081
Thumbturn
0
Model 8066
KEY LOCKS ~
CYLINDER TVPE
MOR11SI ~ GI)
Clutch Lever Entry Trim
1\lbular Model 3082
Mortise Cylinder
Standard diameter five-pin unit with
MS" cam, suitable for use wjth .Entry
Trim on Rim exit (levic::es. All brass
construqion with front "scalp" available
in finishes 628, 313, 335, 605 and 612.
Available In quantity all keyed different
(KD/, in pairs (KAZ) or fifty alike (KASO).
Any other make standard Mortise
cylinder with MS" cam can be used to
"key in" with existing systems.
KEY LOCKS KEY LOCKS P,•••• .... ,..,.. THUMBTURN THUMln\JRN ,.,._ _,
MOR11SI MOR11SE
~ ~ NIA
•-Nlghtlatch
Tradltlonal Model 3083
Rim Cylinder
Standard five-pin unit with spindle to
suit Rim exit devices, /\!!brass with same
choices of keying as Mortise cylinder.
Available in finishes 628, 313 or 335.
Arrj other make standard Rim cylinder
can be used to key in with existing _.~ .....
systems. Note th.at if enqy mm is ~-~ specified for cylinder use the cylinder ·
must be Mortise JWe. ~ardless of exit
device.