Loading...
HomeMy WebLinkAbout2233 FARADAY AVE; E; CB012983; Permit10-26-2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB012983 Building Inspection Request Line (760) 602-2725 Job Address: 2233 FARADAY AV CBAD St: E Permit Type: Tl Sub Type: INDUST 0 NEW Parcel No: 2120612500 Lot#: Status: ISSUED 09/14/2001 MDP 10/26/2001 10/26/2001 Valuation: $21,450.00 Construction Type: Applied: Occupancy Group: Reference #: Entered By: Project Title: OPOTEK Plan Approved: 715 SF WAREHOUSE TO OFFICE Issued: Applicant: C.S.I. GENERAL INC. 1557 GRAND AVE SAN MARCOS, CA 92069 619-432-6677 Total Fees: $1,165.20 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Inspect Area: Owner: CARLSBAD COMMERCE CENTER LLC C/O STEPHEN M ZOTOVICH 840 NEWPORT CENTER DR3f~o.t0/26/01 0002 01 02 NEWPORT BEACH CA 92660 CGP-1040 .. 34 Total Payments To Date: $124.86 Balance Due: $1,040.34 $192.09 $0.00 $124.86 $0.00 $0.00 $4.50 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $390.39 $360.36 $0.00 $0.00 $34.00 $35.00 $24.00 $0.00 $0.00 $0.00 $0.00 $1,165.20 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Legal Description Lot No. Subdivision Name/Number FOR OFFICE USE ONLY PLAN CHECK NO. $ \ ~ L--'l ~ EST. VAL. _~__,_,_..,..t.(.a;,,-5'"'0---, ____ _ Plan Ck. Deposit -½-1....,--"--::,....,..~-- Validated By ____ ~i-=--1----- Date _______ --tri.,..._---t,..._----- Unit No. Phase No. Total # of units , __ ,,,.,--. ,,,,,,_, ·==·· ,,,., ,,. ", •-••·'"'f ,., , , .,,, m, '"'--"'""•• ,., •• ,,. • • ""<.' • "' ,_l'!liru:'' 1'tJ·TiJ'./l\11'.' ;i\"1\1'{".) -0· 1· ·•',t\".f • ,Mj ti<--;., ~!,9_Q,l':ffA9:T:J?.F.~~N!{jt;p,!ff~teijrfrp\\U\llPn11Jint,: .::,,-:-,.,,: ,_" ', ____ ,,,-, .<. ·::,, ,,;-:,,·, "' ' ,;, . ": ''"•1, •• :,,.', . :, 70.C:.J '.iJU,.J.."'t. ,\1'1., wv,. ,,-:·:v;:: '~-,_' Mt,i-.r,tf.J 'I Lo ee:2. -i.S:z.s Gf!ANt' Av1;; . uA SM MNUo5_ cA @::?gt@ 1'14 86 Name Address City State/Zip Telephone # Fax 71 ~:.::, ,:A~e~(if~!IIJ' -:-~:::-[r.cgpJfao~gr-· :i!As~riffc;i~pri!~'!'G~.or-, .i :.Cts:>0,~~:.:. :a~~(I~ f.0:tP:Yi~e~: ,· , .. ::: ~-2 ,~; .... ::.:.~--.. :~.t~;.:~~1fl~1~·~S.:.~l:~;-,;: r; .,<~ :C:. ~en.evn,~ , in, H:z.~ ~P Avt. 6t-:J MN'-G'o( Clt:1ZQl1e, F (::Uo)411-014", Name > Address City State/Zip Telephone # r4;: -~PR0PilRfl'::0••1Ne0· :.: ,,-,._-·.· -:-_ -,-: ,,.-,---"''--~-,--:·-:, -.. :,.:"··· :. _ , ···:, ,.-,,:::··:-_ :"""'.'::· -, .,_-·. _ · :,_..~ ,o: _-,-,,-: -.':-. .-· ,-:,.:.: .:,; · .-:.·-:_.-:.: :., , --. _____ ,. -. , ,"· -,.,.:. _ . _ -. ·_;, , --~i;---·"· ----~ .. ---iciAn---··--'i'~co .w ~i:5' ~ii,---,,.:-3s,t"'"-, ;;J;·NiG -~ -44 ---.. ;-£,i1,11_ ... _ -.. cci,h) iii-~ Name Address City S.tate/Zip Telephone # :S:::: .9.O,N'(13.tX~J'.QR •• .. Q.OJ\'l~All!YJ\IAME. , , , , , -, . ,. , , -' ,,, (Sec. 7031. 5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for 1:he alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500]). C · . . e. ...I c i b, -u~--t 111 ,i-o ' c ~ o . --- Name Address City State/Zip Te ephone # u,~1 r,1 City State License # S: '.?, 10.64 ;9";_ _wq~KE.f\$,~':QQfy'IP~.N$'A:Fl,QN; : ;','.:i~ . · .. :: .. -·.-,,.,,.: .. ;_"-;-·, ·---·: .• ~--":.:. _ .-.':.-,. ~_·:.:: Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: ,4 Insurance Company M IP G:itr-,S ::Co¢:':f Policy No. ,,n .. 00 0 3 t 't, Expiration Date 4 /o i f o'l. • I (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) 0 m the performance of the work for which this permit is issued, I shall not employ any person in any manner so as Laws of California. WARNING: Failure to secure ation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100, est of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. f~'.~~-~~~~·-:::::-~-BU:-., 1,7',_~E~il"'.':.':-:_p::,:,..i_~-.~ .. ~).Oit.,N~, :_~ .. ~-:~-.,_-~:;:;;.:;:;_;_'c=-_ ::-.,_-::-.:~-:---,-,'....,._-:--·-;,,:--::t.::-.~-:-:~~:-;L:-:;,::.:-. __ :-:.:::-·::-=-,~--,_-=-_ :-::::-:----:-_ -.. -:,_,,., ·D-~~~.:::-~-~ -~.: ~--o-, I hereby affirm tha e p from the Contractor's License Law for the following reason: 0 I, as owner of the pro erty or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Cocle for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted _with the following person (firm) to provide the proposed construction (include name I address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work): _______________________________________________________ _ " , ._ -~,' <' " ,,.~-¼, ~,;:' A< l <\,,I Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES /151 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES :el NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 D YES ~NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~-;;:z:iQ'N$:i'RCtg"tT~N.'."CW:J.P.tl'ilG' A~NCW.::::~-.-~:-., --~-" -"' · ·--~ -. -, ... ,, ~-, < '-<-1~ ' ,'"' Vf' ; ;---:Y~'{~ __ .. '.i.:..::· I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY AC RUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excav tions over 5'0" deep EXPIRATION: Every permit issued by the bui authorized by such permit is not commenced at any time after the work is commenced for APPLICANT'S SIGNATURE --~ demolition or construction of structures over 3 stories in height. rovisions of this Code shall expire by limitation and become null and void if the building or work elate of such permit or if the building or work authorized by such permit is suspended or abandor-· ion 106.4.4 Uniform Building Code). OW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request Permit# CB012983 Title: OPOTEK For: 12/10/2001 Inspector Assignment: TP --- Description: 715 SF WAREHOUSE TO OFFICE Type:TI Job Address: Sub Type: INDUST 2233 FARADAY AV Phone: 7604970090 Suite: E Lot Location: APPLICANT C.S.I. GENERAL INC. Owner: Remarks: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs lnsgection Histo~ Date Description 12/06/2001 89 Final Combo 12/04/2001 14 Frame/Steel/Bolting/Welding 12/03/2001 89 Final Combo 11/21/2001 14 Frame/Steel/Bolting/Welding 11/21/2001 24 Rough/Topout 11/21/2001 34 Rough Electric 11/21/2001 44 Rough/Ducts/Dampers 11/20/2001 84 Rough Combo 11/19/2001 14 Frame/Steel/Bolting/Welding 11/19/2001 24 Rough/Topout 11/19/2001 34 Rough Electric 11/19/2001 44 Rough/Ducts/Dampers 11/15/2001 24 Rough/Topout 11/07/2001 17 Interior Lath/Drywall 11/05/2001 14 Frame/Steel/Bolting/Welding 11/05/2001 34 Rough Electric 0 Inspector: .£2.._ Requested By: DA VE Entered By: CHRISTINE Act Comments Act lnsp Comments co TP SEE JOB CARD NR TP co TP SEE JOB CARD AP PY T-BAR WC PY NEED DIRE DEPT WC PY WC PY NR TP CORR NOT COMP. co TP T-CEIL SEE CARD WC TP WC TP WC TP AP TP PA TP SEE CARD AP TP AP TP City of Carlsbad · Final Building Inspection ,, DEG -3 2c.n1 Dept: Building ,Engineering Planning CMWD St Lite Fire ',..,...._____,_ -.-. Plan Check #: Permit#: CB012983 Project Name: OPOTEK 715 SF WAREHOUSE TO OFFICE Address: 2233 FARADAY AV #E Contact Person: DAVE Sewer Dist: CA Phone: 7604970090 Water Dist: CA Date: -1.~/Q~/2001 Permit Type: Tl Sub Type: INDUST . Lot: 0 .......................................................................................................................................................... Inspected Date ~isapproved: __ By: fl6J-Inspected: 12-4--c, I Approved: Inspected Date By: Inspected: Approved: Disapproved: __ Inspected Date By: Inspected: Approved: Disapproved: __ ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••1a111 Comments: _____________________________ _ EsGil Corporation In Partnership with Government for Building Safety DATE: 10/26/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-2983 SET: III PROJECT ADDRESS: 2233 Faraday Ave Suite E PROJECT NAME: Opotek Inc -TI D APPLICANT D JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 1:8'.:1 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: 1:8'.:1 Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person 1:8'.:1 REMARKS: The applicant to hand carry the plans directly to the City of Carlsbad and make changes marked in red on sheet A 1 to the City held sets. This does not assure a permit will be issued the City may have other corrections. By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for Building Safety DATE: 10/22/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-2983 SET: II PROJECT ADDRESS: 2233 Faraday Ave Suite E PROJECT NAME: Opotek Inc -TI ~~NT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected -and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Manny Lopez/ C.S.I. 1529 Grand Ave Suite A, San Marcos, CA 92069 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Manny Lopez/ C.S.I Telephone#: 760-471-9388 Date contacted: lC5ld-&-(by: o) Fax #: 760-471-0149 Mail ..-:Ferephone D REMARKS: FaX--In Person By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 10/15/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 01-2983 II 10/22/01 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-2983 PROJECT ADDRESS: 2233 Faraday Av~ Suite E SET: II DATE PLAN RECEIVED BY ESGIL CORPORATION: 10/15/01 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): DATE RECHECK COMPLETED: 10/22/01 This plan review is limited to the techni9al requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints t.o: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo (• City of Carlsbad 01-2983 II 10/22/01 _ These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6. Please clarify the Hazardous Material form submitted to the county indicate the use of hazardous materials? 2. Please revise the section view of all new interior partitions. Show: a) Method of attaching top and bottom plates to structure. The 2 ½ , 25 gauge stud are not adequate to provide lateral bracing for the 9'11" bracing span. Please revise the detail to show 2-2 ½ 25 steel studs joined to provide the required support. Please revise the bracing detail to show 2-3 5/8 25 gauge metal studs at 6' on center. 3. In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, 11, or Ill-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. UBC, Section 1202.2.2. Please see bold text on item number 1. DATE: November 1, 2001 JURISDICTION: Carlsbad EsGi I Corporation 1n Partnersli.ip witli. government for '.Buiufing Safety PLAN CHECK NO.: 01-2983 REV SET: I PROJECT ADDRESS: 2233 Faraday, Suite E PROJECT NAME: Opotek Wall Height Change D APPLIC~NT &-JURIS. · .. , D PLAN REVIEWER D FILE lZ] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D Esgil Corporation staff did not advise the applicant that the plan check has been completed. lZ] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dave Culver Telephone#: appt. Date contacted: 11/1/01 (by: kc) Mail Telephone Fax In Person lZ] REMARKS: No additional fee is due. By: Kurt Culver Esgil Corporation D GA D MB D EJ D PC Fax#: Enclosures: log trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 b I ',•'.,, . , 0 EXISTING ROOF STRUCTURE .-: • • ....... .. • ••• • :? • • " ..... . _ _., . _, --:.:. • .... : .... ·'! • • . :-; .... ··,·: . . : -~ ..... . . -;, .. NEW 2" SLIP TR.A.CK (3 -5/6') NEW 3-5/6 METAL TR.A.CK. NEW 3-5/8' 25 GA METAL FRAMING @ 24" 0/C 0CBO # 3403P OR EQUIV. '-._ NEW 2x4 SUSPENDED CEIUNG. •••••• • • • • • • • • • • •• • • ••• • • •••• •••••• •••••• • • t..v'--11.."'"' ________ NEW 5/6' TYPE X DRYWALL 60TH SIDES l='A~TITION SECTION (PER USC TABLE 25A-G) 12.i' .---NEW 3-5/6" 25 GA METAL FR.A.MING @ .s-1-' O/C (ICBO # 3403P OR EQUIV.) .---NEW POWER DRIVEN FASTENERS @ 32'· O/C (IC60 # 5457 OR EQUIV.) / EXISTING FLOOO CONDITIONl=D ARl=A / NON CONTIOINl=D ARl=A I .. . . 0 NOTTO SCAL~[ <?~@a~ EsGil Corporation In Partnership with Government for Building Safety DATE: 9/26/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-2983 SET:I PROJECT ADDRESS: 2233 Faraday Ave Suite E PROJECT NAME: Opotek -TI CJ Pl:JQANT CJ URIS. CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [ZJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [ZJ The applicant's copy of the check list has been sent to: Manny Lopez/ C.S.I. 1529 Grand Ave Suite A, San Marcos, CA 92069 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Manny Lopez/ C.S.I. Telephone#: 760-471-9388 Date contacted: c;/ 2 cP I c, (by:FA)C) Fax #: 760-471-0149 Mail -Telephone D REMARKS: Fax v In Person By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 9/17/01 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ·' City of Carlsbad 01-2983 9/26/01 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 01-2983 OCCUPANCY: B TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 9/14/01 DATE INITIAL PLAN REVIEW COMPLETED: 9/26/01 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Manufacturing? ACTUAL AREA: 715 sf STORIES: HEIGHT: OCCUPANT LOAD: 9 DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/17/01 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 01-2983 9/26/01 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6. 2. Please revise the section view of all new interior partitions. Show: a) Method of attaching top and bottom plates to structure. The 2 ½ , 25 gauge stud are not adequate to provide lateral bracing for the 9' 11" bracing span. Please revise the detail to show 2-2 ½ 25 steel studs joined to provide the required support. b) Please revise the plans to indicate the lateral bracing for the partition wall separating the condition space from the non-condition space. 3. In Groups 8, F, M, and S Occupancies, or portions thereof, where Class I, 11, or Ill-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. USC, Section 1202.2.2. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: City of Carlsbad 01-2983 9/26/01 Yes D No. D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 01-2983 9/26/01 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: 01-2983 DATE: 9/26/01 BUILDING ADDRESS: 2233 Faraday Ave Suite E BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Tl 715 Citv Valuation Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1994 USC Building Permit Fee I • I 1994 use Plan Check Fee I • I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee ~ Repeats Comments: D Other D Hourly .__ ___ _.I Hour* Esgil Plan Review Fee ($) 21,450 21,450 $192.091 $124.861 $107.571 Sheet 1 of 1 macvalue.doc PLANNINC/ENOINEERJNC APPROBL--S __ PERMIT NUMBER CB. 0/ J9f} > DATE -------/0 .--f--0 I ADDRESS __ [}_d"_· _)_> __ h--:--. ___ 1-)-_(l_~___,_.Aa=..._· _/lv_t_·5:_· t/_~_-c___.t,~_ -RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) ENGINEER oocs/Mlstorms/Plannlng Engineering Approvals TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING DATE /C~/--d( _;;..__ ____ _ DATE /b [t f 1~ ) ----'---+,-"----- Carlsbad Fire Department 012983 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report: _0_91_26_!_20_0_1 _______ _ Building Plan Reviewed by: Name: C.S.I. General, Inc. Address: 1529 Grand Ave. #A City, State: San Marcos CA 92069 Plan Checker: Job#: 012983 ------- Job Name: Opotek Bldg#: CB012983 -----------------=--- Job Address: 2233 Faraday Avevue Ste. or Bldg. No. E IZI Approved LJ Approved Subject to LJ Incomplete Review FD Job# ------ The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 012983 2nd FD File# 3rd Other Agency ID It 11b5 City of San Diego Planning and Development "Review Information and Application Services 1222 First Ave., MS-301 Hazardous Materials Questionnaire San Diego, CA 92101 THE c1TY oF s.-.N c1Eao Appointments (619 446-5300, Information (619) 446-5000 PART:i: City ,of San Diego Pl~iinln~ '.and Developm~nt'Revl~w ·-·Fire H~zard9us· Materials Pla_n Check~ Occupancy Classification ;- Business Name ft"') 'D;,'?...,,.. L' £,, r,-c Contact Person . Tele_phon~ a V'rC/tF-t<..___ ,L_.I,, cL-1 NAR.G!AL-l'T/--1 76D (~ ( 077-0 Mailing Address 2233 City State Zip Permit # Will your business use, store or dispense any of the following hazardous materials? If any of the items is circled (except item 15), a San Diego Fire Department Hazardous Materials Information Sheet (form FPB-500) must be submitted with your project for review to: Planning & Development Review, Fire Hazardous Materials Plan Review, 1222 First Avenue, 4th floor, San Diego, CA 92101 (619) 446-5438. 1. Explosives or Blasting agents . 6. Oxidizers 11. Highly Toxic or Toxic Materials 2. Compressed Gases 7. Pyrophorics 12. Radioactives 3. Flammable or Combustible Liquids 8. Unstable (Reactive) Materials 13. Corrosives 4. Flammable Solids 9. Water-Reactives 14. Other Health Hazards 5. Organic Peroxides 10. Cryogenics 15. None of These Items PART 11:· San Diego County Department of Environmental Health -Hazardous Materials.Division (HMD): · ·. . . ·. _.._:' · If.the answer to· any of the questions on this form is yes, appl!cant must contact the County of San Diego Hazardous Materials Division, ·1225 Imperial Avenue, 3rd floor, San Diego, CA 92101, telephone (619) 338-2222, priorto the issuance of a building permit. · · -· · Yes 1. 0 2. ~- 3.~· 4. 0 5. 0 6. 0 ~9-~ l:i M Jli[ Jiff Is your business type listed on the reverse side of this form? Will your business dispose of Hazardous Substances or Medical Wastes in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet or carcinogens/reproductive toxins in any quantity_? Will your business use an existing or install an underground storage tank? Will your business store, use or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 1 0)? PART Ill: San Diego Air Pollution Control District If the answer to any of the questions on this form is yes, applicant must contact the Air Pollution Control District, 9150 Chesapeake Drive, San Diego, CA 92123, telephone (858) 650-4550, prior to the issuance of a building. permit. -· . - Yes. No 1. 0 tz1 2. D 0 Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution Control District Permit Categories reverse side of this form? (Answer only if the answer to question 1 is yes) Will the subject facility be located within 1,000 feet'of the outer boundary of a school (K through 12) as listed in the current Directory of School and Community College Districts published by the San Diego County Office of Education and the current California Private School Directory compiled in accordance with provisions of Education Code Section 33190? 3. D oo' Does the building or structure for which this demolition permit is requested contain any friable as- bestos? OFFICE USE ONLY H# -------BP DATE _!_}_ SA/M _' ___ _ APCD _____ _ OFFICE USE ONLY D Cal ARP Exempt Date Initials D Cal ARP Required Date Initials D Cal ARP Completed Date Initials· I declare under penalty of perjury that to the best of my knowledg onses made herein are true and corre6t. 7 FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________ _ By: Date: RELEASED FOR OCCUPANCY COUNTY HMD APCD This information is avai alternative formats for persons with disabilities. To request this information in alternative format, call (619) 446-5446 or {800) 735-2929 (TT) Be sure to see us on the World Wide Web at www.ci.san-diego.ca.us/development-services os:3153 (01-01) · .. · FAX TRANSMISSION Wednesday, October 10, 2001 PAGE 1 OF .,_L TO: FAX PHONE Dear Manny, Manny Lopez 471-0149 471-9388 FROM: FAX: PHONE: , Eli Margalith 760-929-8782 760-929-0770 OPOTEK r.nanufactutes tunable laser systems for various applications. The products include lasers, whi.ch are manufactured by other companies, and various modules that enable to tune the lasers to different colors. The systems are primarily sold to universities, research institutes, and national laboratories. OPOTEK started to operate in June 1993 and since July 1998 it conducts its operation in the current location at 2233 Faraday Ave, Suite E in Carlsbad. No machining or other manufacturing processes takes place in the facility. All the machined parts and the purchased equipment are delivered to-OPOTEK and the only activity in the facility is receiving, assembly, testing, and shipping. There are no hazardous materials involved in these activities and there is no fire risk. The present project objective is to convert about 770 sqft of warehouse to an office space, clean assembly, and a kitchenette. Please call me if you have any questions or need more information. Sincerely. Eli Margalith, President