Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2233 FARADAY AVE; D | E; CB880072; Permit
) ) L) ~ ,-d1'eby affirm that I am licensed under _,.,,fslons of Chapter 9 (commencing with l i. I USE BALL POINT PEN ONLY & PRESS HARD JOB ADDRESS, - CARLSBAD BUILDING ·DEPARTMENT 2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619) 438-1161 APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. APPLICATION & PERMIT BUSINESS LICENSE # <Section 7000) of Division· 3 of the Business . ~ and· Professions Code, and my license is in ~ ~ fun force and effe.ct. . i "2-"Z-°3-~ I ~~~ J:<_~~v. ST.Rb·: r;;:_As BROS NO. ,~n:ftfNI Ill z 0 ~ IC c( .., irl 0 (.) :C I ·hereby a111im that I am ex~mpt from the Contrac· lo['s License Law tor lhe followmg reason (Sec. 7031.5 Business and Professions Code: Any city or county wh1cli re· Quires a perm11 to construct, alter. improve. demolish, or repair any structure, prior to its issuance also requires !heap-plicant for such permit to file a signed statement that he IS LOT I BLOCK ., St/BDINISJCn-t .1 ~s···~so. R PARCEL ,g. / _., _ CONTRACTOR r:Z-. ~ CJ &;:? • -. I,,"" . . ,-r""' .• CONTRAOTORS·P.HONE # ?.53 tY,:J IC· w 0 .., 5 Ill ii: w z ~ 0 z 0 ~ Ill z w CL ::E 8 ril a: w ~·· 0 ~ ffi[ ~ . w ...J licensed pursuant to the ·provisions of the Contractor's ·j OWNER'S MAI i.·, NG ADDRESS ~1~~;,~~ }~o/,~;hsaJ~f;e;;~~~~;~~,~~o~;'~o~~rd~~h~~~s0e~~ . i . . . -< · A empt therefrom and the·basis tor·the alleged exemption. Any .j, -2 Z33 '· rAJ,ff.A-IJ l."'1 v g., v10lallon of Sect10n 703.1.5 by an applicant tor a permit .sub· ·• . . . . · · · · · Iects tfle apptjcant to a clVll:penally of not more than five·hun· 1 01;:SCRtPTIQN OF WORK ·owNER'S,NAME J/. ' . . T\;11 .Q ~A.I) ., DtSIGNER -·--., . OWNER·s PHONE i)tf.if,ft.S . CONTRACTOR'S A~ORESS 7 i'f_,,v..N J'.S l~/0 E~·9~ ,AA A.le{ "-IA--Lf 1--STATE LICENSE NO. 7 '292..LS-L DESIGNE,R'S PHONE ·dred dollars ($500). I 1------:;;.;:;---.;....---,-;--l"'--...;.-==:c------.;....-----------~-t DESIGNER'S. ADDRESS STATE LICENSE NO. I I I. as owner ol the property, or my employees with wages · 1. · as their sole compensation, w1ll,do·the work. and the struc· l lure JS not intended or offered tor sale (Sec. 7044, Business 1 and Professions Code: The Contractor's License Law does not apply to an owner o't property y,ho builQS or improves I thereon and who_does suCh work himself or~lhrough his own employees, provided that·such improvements.a.re nol intend-~ · i!d· or offered to·r sale. If, however, the building or 1mprOve-I 0£FJL:::...r=!.. F/P vO NO F LR ELEV. NO STORIES CENS)JS·TRACT PARl(-ING SPACE RES UNITS GRADING PERMIT ISSUED REDEVELOPMENT TYPE ARE·A CONST ,~~ EDU t-i-D DCC LOAD FIRE SPA BUILDING sa. FOOTAGE ·•-~ u.. >; ~ 0 a. E Cl) I- I 'O 0 0006 02/02 0101 02I::ldPmt . . . 1350 .. tilff (9 ment IS sold w1thm one year of'complelion, the.owner-builder I will have the burden of proving that he did ri9t build or im· I prove for the purpose-ct sale). I v O N O v D NO vD NO Not Valid Unless Machine Certified _ I I I, as, owner of the property, am exclusively contracting wit~ rrcenseo contractors to construct the prefect )Sec 7044. Business arid· Professions Code: The Contractor's ticense Law-does not apply to an·owner·of property who builds or im· proves thereo)l, and who contracts for each ,projects with a conlractor(s) license pUrsuant to the Contractor'.s Ucense Lal'!), _ _ I J As.a homeowner I am.improving my home, and the follow ing.condiUons exist: · . ...-1. The\vork 1S being performed-prior to sale. ~-I ·have lived m my home for twelve nionms pnor to complet1on of this work. .3. I have not claimed this exemption during the last three years. D l·am exempt under Sec.·. • 8 & P C. for this reason ___ ·------~-~~- 0 I hereby affirm that I have-a-certificate of consent to self-insure. or a certificate of W01kers· Compensation In- surance. or a cerUOed copy thereof (Sec. 3800. Labor Co~e) POLICY NO. COMPANY ~ Copy Js fl led with the city 0 Certified copy is hereby furnished CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (Thi$ section need not be completed 1f the permit 1s for one hundred dollars ($100) or less) 0 I c;~rtlfy·th~t In the performance of the work for which this perinit 1s issued. I shall 11ot'employ any person m any mgnner so ~s to become subjecuo the Workers' Compen- sation Laws of California. -NOTICE TO APPLICANT: JI. aftermakmg this Certificate of ExemptiOn. you should become subject to the Workers' Compensation provislbns of the Labor1Code: you must forthwith comply with such provisfons Qr' this perinit.shall be deemed tf!!VOked. l· I QTY. PLUMBING PERMIT -ISSUE QTY. EACH FIXTURE TRAP EACH BUILDING SEWER EACH WAHR HEATER AN01DR VENT EACH GAS SYSTEM ·1 TO 4 'OUTLETS EACH GAS SYST-EM 5 OR MORE EACH INSTAL.. ALTER, REPAIR WATER PIPE E.A,t;H VAC_UUM BB_E,AK_ER WATER SOFTNER EACH ROOF DRAIN I INSIDE! T·OT At-PLUMBIN6 · T QTY. ELECTRICAL PERMIT -ISSUE \..I-QTY. NEW CONST EA AMP'SWT BKR I PH 3 PH EXIST BLOG EA AMP/SWT'BKI{ I PH 3 PH ~ RE-MODEL'ALTE11 PER CIRCUIT -Z...-'t'-\ ..I -T-E-MP·PO LE · ioo AMPS-· OVER ioo AMPS MECHANICAL PERMIT· ISSUE ;r-SUMMARY/ACCOUNT NUMBER INSTALL FURN. DUCTS UP TO 100,000 BTU ,q BUILDING PERMIT 001 ·810-00·00-8220 OVER 100.000 BTU 7. SIGN PERMIT 001·810·00-00-82 21 BOILER/COMPRESSOR UP TO :i HP PLAN CHECK 001-810·00-00-8891 BD.llER/COMPRESSOR 3-15 HP TOTAL PLUMBING 001·810-00·00·8222 METAL FIREPLACE ELECTRICAL 001-810-00-00-8223 VENT FAN SINGLE DUCT l.~ri MECHANICAL 001·810-00·00·8224 MECH EXHAUST HOOOIDUCTS. ..,. ,:,;:-"Ql \'\JV MOBILEHOME 001 ·810-00·00-8225 RELOCATION OF EA FURNA_J.;,.f\n(EJl.fi:131 ~.ll-r .SOLAR-001 ·810-00-00·8226 DRYER VENT 'U,..., 1,,...('1\l II STRONG MOTION 880-519-92-33 HlTi:;'L MECHANICAL \j I rl \"~U.: .. j..,_, . FIRE SPRINKLERS 001-810-00·00-$227 -t'c.. ~~ . •le __ PUB~IC FAQIUTIES FEE 320-810-00·00-8740 M_OBILE HOME SEJ~ «,1! ~ -,.u{t':,':,\~G -::,1,;.~ 'P""BRIDGE FEE 360-810-00-00-8740 · ~'a ~ -~•-t. i'>ti PARK-IN·UEU (AREA ) CAR PORT ~., ~\ ov~f\t,\U - AWNINGA()--..,-..-----~6'~ GARA9'..'\7 ,{.\ ...,.~ \ IN --L.'i CtB 1988 T~ Cn1r -.-f:~~I) ~ g\ iiili ~ \~ i.:1!.Y ofr.':i~~!-!ittj~ __ . :.::l TIF 312·810-00-00-8835 LA COSTA TIF 311·810·00-00-8835 FMF _ - LICENSE TAX}j.,..5 001-81°0-00-00·8162 MFF • "'2.n 'l_ /-:,[ll Q__ 880-519-92-57 T tf!i- 17)3 -. Pjl) .--,/ - --z:, ,1,4 ---~~- z .. ; 5 -7,_T2'/, "7' TEMP OCCUPANCY 130 DAYS) \~ "NirLSB .. ~ .. ,1)-r,?"-' i.-0/ I II I • -~ -'-~-----. _!_•-_! __ • _ ____d~. . 1 1 . I t "-':9. . . ,. ,i, 1/ t i CREDIT DEPOSIT · 1 TOTMHEC1'1CAL I . ?-;/).-f : . .,~~--!OlAL·' =. .=C .. TOTALFS:ESPA¥ABLE D I hereby affirm that .there is a construction lending ! agency for the performance of the·work for which this per-1~- rriit, is lssu~d (Se~. 3097, Civil Code) 1 HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" ANO DO HEREBY I Expiration. Everyper.mitissuedbythe.BuHdingOffic,afun!lertht)provi~,onsofth,s . * AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS bl/ER CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE . Code shall expire by hm_,ta,t,on 8nd become null ~nd void ff the bwld,ng or work 5'0" DEEP ANO DEMOLITION OR CONSTRUCTION OF authorized bY. such permit is not commence,:l within 180days from the date of such DECLARATIONS ARE TRUE AND CORRECT AND f FURTHER CERTIFY AND AGREE IF A PERMIT I& permit, or ; he building or work authorized by such permit ,s suspended or JRUCTURt:S OVER 3 STORIES IN HEIGHT ISSUED: tO COMPLY WITH ALL CITY. COUNTY AND STATE LAWS GOVERNING BUILDING CON• abandoned at n lime after the work 1s commenced for a enod of 180 da s · ~ Lender's Name ___ ~~---~---- Lender·s Address ____________ _ STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY ANO ; rV • I KEEP HARMLESS THE CiTY OF CARLSBAD AGAINST Aj..L LIABILITIES. JUDGMENTS. COSTS AND AP IC S SIGNATlfRE Jf. OWNER O CONTRACTOR Y,. I EXPENSES WHICH MAY IN ANY WAY_A'CCRUE AGAINST SAlD CITY IN CONSEQUENCE OF THE. BY PHON.E tJ I... GRANTING OF THIS PERMIT. • I C ,u (.) a. a. <( I .:,c C 0::: 0 Cl) Cl) Cl) Cl) Cl) <( I ~ .2 ai >- Cl) (.) C Cll C u:: C, Cl), ~ (!} 0 u Cl) a. Cl) C 2 :c· ~ ~1 f\, ; 'i": Iv,,: J~t l p, ~ t ~:~~:~: . :•·TIP§_ ~IDlQ!Nq:_ l ·i:· -•.: ~; -·» :··r ;;--~-. ,:.,_:: ,?-/<:'..:::~::.:,·----.-<' -~ .. -~ ,c-1 ·•., .. L·y:::•~•S ?·),~~: -~,·• • ,/.,:: ;,~<-::-::·:~_~',·,·,,: ,-·: .. : .. ~~=:-~:;:~::_.\./e!. ~.OATE".~'-INSP.EGTOR'· c.,.:· ··0 .>' ::, __ ·_, -~ -"'-. . · ... /'.?~8:'81')<?,7,~,.•. , ........ ·::.·,··:'·-~:-;-,, .. _ '-~~ !~~ ~~1~-i~ :·;~~~:-~~-~:. ~~---~~ ~~~ l !=-~TJ=~IQRtATH:. ·.·t ····.!··J . •,.. ,. ·a .. · ·GV~R;-2Q00f?l-, -~-.. : ·:·l.-A tt.1). ,;;::.·, . ol. ; .:.. . . ·. -.. ', '. . .:.-.,.• .-.. , ,.,-.· .. /.•.' .. ,L f. • .: · .. :1:;t0l;H · &:~¥WA Lt .. · .•• : ·;·.-.i·. c.·: · .. ·~ ,,.~-:~:•. ,~:. '.!ii,~f ;E?'.~. -.f ~~~:~;,£!:: ~ ·}:· .~~ ~-:···~:~:~ 2~:~}:~~t\:!:::Iti .... ·· · .. 0 1· ''f' "1:., .··PLUMBING· I I ', '-~-,., : .• •., ·,..... ' FIEl:.DWEl:.OING. ..''1 ... ·.•.. .. . • . • . ·:...,,, ··~--::......:., ••. ...,...,, __ .:......:.-,.-..... _. ___ ~.-. ...;..-• • .:-... --------~ .......... •. ,. D WA+ER-HEATER D SOLAR·WATEB-·, ·. · · · · --· · · · · .. · -...... ,.,,.. · ... , ... ,.,_._. __ .__.. -, _____________ -.-----···---. ······ .. -.. · -. J . · · ... , ... -·1 ·,c ,· i ~ ~ r ,, . -Q • ! ii~' ~ ~ \ > ?~. ,, ' ~-i t ,,, z S-: tt D. :BONDIN.G1·' ·•n 'POOL"'· .. · -J.'· ) ·· t' • . · -'"' 1 · ' .... , ... •• u~ .. ,< ,,_ . '') <· • · , .. • . · ·"~-~-·,. "'-' -~.:-:-.,4 , •• • ... ·• • ·, '·. • .,, ,., '' ·,-., ._,,. .. ,_._ t , .. ,:, ' J: _ .·1,:.-, .. ,:,.-1':.:1'.. --~·-:.,.' .... ' .. ::.·;·.·.·i,:\·~---"::-... ~·"':.J-¥,. '~-,,~,J...-•#" .... •.-... • ! ·.y· ..... :·,,·.1·_._,,..: ~·--~· ··· ·_. -_..,-.,. . ----.,~...:._,--_r ·· · · · ~ ~0i~i~:~~iZ7 ~5:J~=~~~~1. :Y:·ENTJUfi:'ING;-S¥$1;:EIYIS :. , -··-'.·.1·. -.. ·, i. :,: :,,.,1 • --i:. .. , .r,.,_ r-... -.. --~~-· ··-" . ~ _¢'.lf/i'f·FoR.:FtNAL t&se~9;fi~ciN::.~He¼1:1(LL~~P):~R~~ii!J:!'-,: ,._., · · ·::--· --~;1· .~~ t: .. -, ... -:: /:TE-MS A'BOVE'..HAV.E.BEEN.APPBOVED;:_ . .\ ::,;:,:.:,·_;··:-:''-:. ::, , ... , ·. -·· :\' Pi-WMl}JN,Cz l'l~Al . ;' . . ' . -., -. '! :ELECTR.ICAb --; .. .. . .. · • , .. --· .,. ,,~ .-.,_) .. ~;_ ... ,::(';'._.._,_. MECHANICAL· "· -~;;~;J~Jl~~;v ·'·: --\£_, .,~ ... i:,~.:::;~:~,,.·· . ~t·:_. ~-~ . ____ ,,,,. .,-·:·:----,_~\__ ----~ .. _.··. J'';.~~'..¼../~'t ;,'-,,!~-1,,._·.;~·,.!:,.';.\-· tr·;.~·: ·1:;_~· · r,,,.. .. • 1· ··--~ - -~--· ...... _ ~ 1:; il .::-.-~~--:.-·:. :--. ::Jft-~~~~~~-'.:-i~,.; -, ·~ ~-------:· ..... -· -"". ~ -- ---~-,-, ~ -___ ,... -·~ ~~r -. -----~:.,. ..... _. .. _ .......... -~---·· ::.--;-~ . ---~-, ~ '>; .<, ·':':-' ~i;·; :=f·i~-~1;~7. _.__. __ .. ,---.,.,:. .. .,. ... -.~-: -'!. • l - "" , ~~ ~- DEVELOPMENT PROCESSING SERVICES DIVISION 2075 LAS PALMAS DRIVE CARLSBAD, CA 92009-4859 (619) 438-1161 MISCELLANEOUS FEE RECEIPT Applicant Please Print And Fill In Shaded Area Only JOB ADDRESS ASSESSOR'S 'PARCEL NO. OWNER OWNER'S · MAILING AD.DRESS CITY CONTRACTOR SUBDIVISION------ LEGAL DESCRIPTION DESCRIPTION OF WORK CONTACT PERSON ,ADDRESS 'CITY ZIP APPLICANT'S SIGNATURE White -File TEL. Yellow -Applicant 0020 01/18 0101 05Misc. 84-00 VALIDATION AREA· ESTMATED VALUATION -~I_.._Z__._/_Sc_e.;_d_ ~ry K IF SUBMITTED: D 2 STRUCTURAL CALCS DATE GIVEN/ SENT TO APPLICANT DATE LA COST A LETTER SCHOOL FEE FORM P & E CORRECTIONS LIST CERTIFICATE OF OCCUPANCY Pink -Finance Gold -Assessor @ I J ,I 1.. \ )' .. FINAL BUILDING INSPECTION RECEIVED .l I! t\1 2 5 1988 PLAN CHECK NUMBER: DATE: 1-:J.0-39 PROJECT NAME: --------------------------------- ADDRESS: ____ 2_2_3_3_F_,3_r'_i.l_d_,l_.·•_f _n_p_,r_, _e,_n_f,_}_i3 ___________________ _ PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: _______ _ TYPE OF UNIT: __ T_l_t_J_'f __ fi ___ C--~ _______ NUMBER OF UNITS: CONTACT PERSON:, _____ l_f_n_f .. _~n_O_'i._'J_rt _______________________ _ CONTACTTELEPHONE: ____ 1_,J_n_h_·n_o_t_'J_n ______________________ _ INSPEC~----DATE 1/?.{ir<; APPROVEDr--INSPECTED: DISAPPROVED BY: ~ INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS:----------------~----------------- Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire ' . /I I t' ,. ... ' ~; '', : ,-~ \ ", ,' .. ,, .' FINAL BUILDING INSPECTION PLAN CHECK NUMBER: JB0072 DATE: PROJECT NAME:--------------------------------- ADDRESS: PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: TJ Qffk';tJ NUMBER OF UNITS: CONTACT PERSON: _____ •----•-r,_t.\~t1 ___ >:l_t,. ___ Tn'-'------------------------- CONTACT TELEPHONE: ____ I--'-U_n_t~_:n_'l_·,_-,_n ______________________ _ INSPECTED-.~ BY: ___ .._.~'"--L------ INSPECTED BY: _________ _ INSPECTED -BY: _________ _ DATE INSPECTED: DATE INSPECTED: DISAPPROVED __ _ APPROVED DISAPPROVED __ _ APPROVED __ _ DISAPPROVED __ _ COMMENTS: --------~------------------------- Rev. 1/86 WHITE: Suspense !?LUE: Water District GREEN: Engineering CAt:JARY: Utilities PINK: Planning GOLD: Fire ' ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 '\°2~ 't>. ~l l.-\ \ \' l 2' ~ SAN DIEGO, CA 92123 (619) 560-1468 DATE: q 26( 82:i QAPPLICANT RISDICTIO JURISDICTION: C\4fLLS~A 0 PLAN CHECKER QFILE COPY QUPS ODESIGNER PLAN CHECK NO: CB ~<?-0012 SET: T PROJECT ADDRESS: 22-9'5 ~Pr(2..)9-0'A-i_? i4utd • PROJECT NAME: s'-.>\"""T'<::::~ ~ e <5:' ----''---------------=-----'~-='-----==------ ~ The plans transmitted herew.ith have been corrected where W& necessary and substantially comply with the -jurisdiction's D. D D D ·buildi~g codes. The plans ·transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified-,----=----------,--,,---are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the ,enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans·· are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. O The applicant's copy of-the check list has been sent to: ~ Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: ____________ _ \ Date contacted: ---------Telephone# -------- RE MARKS: --------------------------- By:-;:t°M G,Ls~, A l-..1 ESGIL CORPORATION Enclosures:Q~~l~~>-=._ft__;_;_-W.;:;__:S ______ _ \ JurisdictionC~BaO Date1~8 Prepared bys ~W\ VALUATION AND PLAN CHECK FEE Cl Bldg. Dept. O Esgil PLAN CHECK NO. Ct:> 8~-0012 BUILDING ADDRESS 22.. '53 ~A 'DA-L.f Ave'· APPLICANT/CONTACT~:P,))\S) \1)7t..<..~<-tN PHONE NO. / 53 ~ C,4(.,?::, BUILDING OCCUPANCY ~ \C -2... (_-;(. I '..2 DESIGNER PHONE ------ TYPE OF CONSTRUCTION \J -N. CONTRACTOR PHONE ----- BUILDING PORTION BUILDING AREA . -VALUATION VALUE . MULTIPLIER .J (')~06 9-5ol-f (<i D~ l 8, ~0 :: .. 1 '115r-r~ I Air Conditionin.e: Commercial @ Residential (c3 Res. or Comm. Fire Surinklers @ Total Value l/751·s-· Ouilding Permit Fee $ ( 89, 0 0 ---'---=--------------------'"--------- Plan Check Fee$ l1.'2,S5 $ --'"------------------:!:...------- COMMENTS ... :--------------------------- SHEET OF --12/87 CJ "'O a, 3:: a, > a, c:: D CJ "C a, 3:: a, > a, c:: D D D D CJ "C a, 3:: a, > QJ c:: D D D D ~DD @ D D D D D D D D D D D D D D D D D D ENGINEERING CHECKLIST LEGEND Date: __ ..... /---'-2"---8 ___ --=8-=8,____ ____ _ ~ @ I tern Complete Plan Check No. Cl"-"-~-"a"'--Ba....00 ___ 7:.._Z---___ _ Project Address: ,V.33 FAraqo;:N I tern Incomplete -Needs Your Action Project Name: ___.T--=I'----------- Field Check Date: 1,2,3 Number in circle indicates plancheck -----------By: number that deficiency was identified LEGAL REQUIREMENTS Site Plan 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway and percent (%) grade and drainage patterns. Provide legal description of property. Provide assessor's parcel number. PERMITS REQUIRED Grading 5. Grading permit required. (Separate submittal to Engineering 6. 7. 8 .• 9. Department required for Grading Permit). Grading plans in plan check PE ------ Need the following completed prior to building permit issuance: A. Grading plans signed. B. Grading permit issued. C. Grading completed. D. Certification letter and compaction reports submitted. E. Grading inspected and permit signed off by City Inspector. Right-of-Way Permit required for work in public (e.g., driveway approach, sidewalk, connection to ·etc). right-of-way water main, Industrial Waste Permit application required. To be filled out completely and returned to Development Processing. Ptft D ·o @o D ~~ 0 D ~OD ~DD @o D ~o·o FEES REQUIRED 10. Park-in-Lieu fees required. Quadrant: _____ , Fee Per Unit: , Total Fee ..... ------- 11. Traffic impact fee required. rJJ, Fee Per Unit: _____ , Total Fee: f /3,;3 12. Bridge and Thoroughfare fee required. t;J-.~ /J~.L Fee Per Unit:_-:_-_-_-_-_-:_-_, Total Fee: ?1.61"1,s~ 13. Public facilities fee required. 14. Facilities management fee required. Fee:======-=:- 15. Additional EDU's required: _ __;.2;..._;;0__,,.. ____ --=---_ Sewer connection fee: 200 Sewer permit no. 3]93 16. Sewer lateral required: _..;..~ .......... ;.=-;,-"'F-------- O.K. to issue: Date: If you haye any questions about any of the above items identified on this plan check, please call the Development Processing Department at 438-1161. . Q) Q) Q) ..... ..... ..... ca ca ca Cl Cl Cl co co ca "O "O "O Q) Q) Q) == == == Q) Q) Q). > > > Q) Q) Q) c:: c:: c:: ,.. N M =ti= =ti= =ti= u u u a. a. a. ODD ODD DOD DOD ODD PLANNING CHECKLIST Plan Check No .. CB88c:D72. Address 1,,233 /7wp.a9y /)11e, Type of Project and Use TI- Zone t;M Use Allowed? YES K. Setback: Front 41±-Side $It Rear !:!./,8__ Facilities Management Zone 5 School District: San Dieguito -- Carlsbad ~ Encinitas San Marcos Discretionary Action Required Environmental Required Landscape Plan Required Comments YES YES YES -- -- NOL NO-A- NOA NO Type __ -------------------------------- Coastal Permit Required YES No_J2{_ Additional Comments ------------------------ OK TO IS~~::::·==-=..:::==---DATE l-za--88 .... ,,. . Certificate of Compliance (Part 1 ~12) ' -- p ectlui S PU., DMFTt{'\6 ProjectAn:hitect/Engineer Bl.liking Pennit Number. 2-2.:.33 FAl½f?A'f AN£, 1 Su 1TE.$ B -rC. -, Project Location CAALS{zAP CllmateZOne 17e:[3o /~7 D la, Prescriptive Approach/Performance· Approach Strategy- General l.aw R_t$E. 1 CEC Occ:upancy Type • • • • • • • • • .Oi=F I¼ 2 UBC Occ:upancy GroupJDMsion • • • • • B -2. 3-Package Se!~ .......... /)~~ 4 Gross ConcitiOned Floor Area • • • • • • I 7P '3fo tt2 Roof.ancl-Floora. 5-Proposed RooUCeiJlng·Rt (CF-2~ CF-3) • • '2&,,$'L hr-F-ft2/Btu. 6 Requlntd RooUCelUng,Rt (CF-2) • • • • • ± hr-F-ft2/Btu 7' Proposed Ex1arlor Floor Rt (CF-2, CF-3) • • hr-F-ft2/Btu 8: Requlntd Ex1arlor Floor Rt (CF-2) .. • • • • hr-F-ft2/Btu Walle 9. Proposed Opaque--WaD•Rt·(CF-2, CF-3) • • ~ hr-F-ft2/Btu.. 10, WallHeatCapac:ity,(CF-3) ••• l~·9f.l,.4~ Btu1F-tt2 11 RequlntdOpaque WaU·Rt(CF-2).. • • • • NA hr-F-ft2/Btw- Glulng·ln. Walla- 12 Exterlor.WallArea.(CF-2)-.. .. .. • • • • • '.2!e12$ ft2'. 13 Total Glazing.Araa_(CF-2) • • • • • • • • 47'2.. tt2' 14-PropoaedTotal,Pen:ent{Une-13'/ Una 12). !7, fe ~ 15, ~verage.Total SC (CF-2)' •••••••• , • 11 16 Allowed Total.Glazing Pen:ent •••••• ~ % 17 West Exterior Wall-Are&{CF-2) • • • • • • ~z3-tt2 18 West Glazing Area{CF-2) • • • • • • • • 0 tt2 19· Propoaed West Percent (CF-2)·. • • • • • 0 %, 20 Average West SC (CF-2).. • • • • •. • • ~ 21 AUowed West Glazing Pen:ent-. • • • • • _L %, Glazing In-Roof (Cf-6), Proposed Allowed 22 Skyffght 1 · • • • • • • • • • 0 f\ A 23 Skyffght 2 • • • • •. • • •.• __ _ 24: Skylight 3-. .. • • • • .. • • __ _ 25, SkyUght 4 • • • • • .. • ·• • __ _ 26, Skyffght S:. • •-• • • • • • __ _ 27 SkyUght S-. • • • • • • • •. __ _ 28 SkyDght 7 • • • • • • • • • • -+--- 29 SkyDght 8• • • • • • • • • • , 11 '1, Ughdng (See Part 2 fOt Additlonat Performance Specilications1 30 Propoaed·A'*-'stecl I.PD (CF-5)-•• , • • • /.43 31 Allowed LPD (CF-5) • • • • • • , • • • • I • 4?;, HYAC (See Part 2 for Additional Performance Specifications) tt2 tt2. tt2 tt2" tt2 tt2 ft2' ft2· Watta1ft2 Watts/ft2 32 . Performance Set Selected • • • • • .P.G-~C..£. 33 Proposed Fan Wattage Index (CF-4) • • , 1 °3S2. Watll/ft2 .34 ADowed Fan Wattage Index • • , , • • • ~ Watta1ft2 35 Proposed Cooling Power Index (CF-4) • , ~ Btuh/ft2 36 Allowed Cooling Power Index • • • • • • ~ Btuh/ft2 37 Proposed Heating Power Index (CF-4) • • ~ Btuhlft2 38 AOowed Heating Power Index • • , , 1 1 1 NA 81Uh/ft2 Form Reviled September 1986 CF-1 For Enforcement Agency Use Only Slgnatum and Registration Stamp 0818 Fl8id checked By Approved By Performance Approach Energy-Budget, !..ow ~lSe 1 CEC Occ:upancy Type. • • • • • • • • • PF8Ck 2 UBC Occupancy-Group/Divilion • • • • • B-2.. Oa1e Date 3 Condlloned Floor Area • • • • • • • • • / l:,3{a tt2 4 BudgetTable •• o ••••••••••• 2.-53@. 5. Allowed·Energy Budget (WS-1A) • • • • • I 3b-kBtu/yr-ft2 Calculated Annual-Energy Conaumpdon 6 Approved Calculation Melhod • • • • • • $CM 7 CEC Designation ••••••••••• CP0-O-Z..F a Mu1t1p11er • • • • • • • • • • • .• • • • • 1-0'2. J Estimated En-say u.. . 9, Healing,. • •. • • • • : • • • • • • • • I 'Z.-• '2,. kBtu/yr-ft2 10· Cooling • • • •. • • •. • • • • • • • • • '2--1 , 1 kBIU/yr-ft2. 11' Fans • •. • • • •. • • • • • • • • • • • I lo . 3 kBIU/yr-tt2 12 Lights • • • • • • • • • • • • • • • • • '2± · $ kBtu/yr-tt2 13, Miscellaneous, Equipment·. • • • • • • • I @. 2 kBIU/yr-ft2 14 Total, • • • • • • • •. • • • • • • • • • __,,,,.,,....,,,_ kBtu/yr-ft2 ts· A"~ Total ~nergy-Uae (Dne.8-xJlne 14) •• , /3?, .9 kBtu/yr-ft2 Compliance Statement General. The proposed building repreaentecl in this set of. complianc8l documentation is consistent with the other compffance forms and worksheets, with the plans· and s~ffcations. and with ~ other calculaliona or computer nma submitted with this pennit applicalion. Performance Approach. (when applicable) The energy performance estimate· presented on this-form. was calculated using !he approved calculalion method indcated above and with the CEC eistabDshed fixed and restricted engineering inputs for the applicable climate zone and occupancy type. Prncrlptlve proach. (when applicable) The proposed bullclng hes been· design to meet the-requirements of the Altsmalive Component Package i ed above for the appropriate occupancy type and climate zone Clty/StetelZlp 75=~ t C/63 '/22,f 1J Telephone Calif. UcenH Number Page_of __ cf?;g-&0072.. Certificate of Compliance· (Part 2 of 2) CF-1 p,£1.::f'fiff*l CoAA For Enforcement Agency Use Only Oocumentadon Author/Finn 1 2-{3.o J B 1 Data Checked By Data Both part1 one and two of lhis Certificate of Compliance must be included with each building permit applicalion for Iha above noted building and appear on the plans submitted for approval. The building features and requirements represented on Iha. Certificate of Compliance are adequate to achieve compllanc:e with lhe second generation n_onresidenlial ,nergy s1an~rd1 for the. ~i!ding referenced above. The.building features and requirements are also-adequate for any subsequent alterabons. modificalions or add11ions to the building. D01lgner One, /)4µ,~{J A L 2i \ /j M1 Enforcement Agency Signature Data Enforcement Agency Signacure Document~tion Author: Haynal & Company 350 E. Grand Ave. Suite 204 Escondido, CA 92025 12, so B Dat Dealgner ThrH· Name (Print) Tide/Company Name Address Signature Enforcement Agency slgnatute Dealgne,,·Four Name:(Print) Tide/Company Name Addra11 Signature Enforcement Agency Signature Enforcement Agency Name, (Print) Tidal Agency Address Date Date D_ate Date Page_ol_ Mandatory Measures Checklist Pl'OjectTi e ~ H:a'tN:Ak e Co . Documentation AuihJIFlrm Envelope Measures Reference in Con1truction Documents [ ] Certified lnaulallon mallrlall per 2-5311(•) • • • • • • ., __ _ [ J Insulation inataled ID meat flame spread ancl'smoke· denaity.111qUinlments of 2-5311 (b} • • • • • • • • • • •. __ _ [ ) Un111 fonnaldehyde foam lnaulalion Is inatalled·· per2-5311(c) •••••••••••.••••••••.• , __ _ [ ) Retrofitlnsulatlonspecifled as per 2-5313 • • • • • • • __ _ ( J Air infiltration ls minimized by specification of teated manufacrured doOf'I and wlndows:and proper sealing and weatherstripping.as per 2-5317 • • • • • • ...._ __ Lighting: System Measures· [ ) Certified luminalrealballasts per. 2-5314(b) • • • • • • • __ _ [ ) Independent control w/ enclosed areas per 2·5319(a) • • __ _ [ J Manual switching reaclly accessible per2-5319(b) ••• ...__ __ [ l Reduc11on oMightlng·load to at least one,half per 2-5319(0); Occuf>8:11CY sensors or programmable tim~ meeting_ CEC crilarla may. substitute,. • • • • • • • • ., __ _ [) Sepa,ateswltchingofdaylltareas.per2-5319(d)· •••• __ _ t J Separate switching of display and valanee:llghling, in retail and wholesale stores per 2-5319(h).. • • • • • ,__ __ [ J Automatic control of display lklhlln.g In retail and wholesale 1tores per2-5a19(h} •••••••••• __ _ [ J Tandem wiring.of one-and three-lamp lumlnaitas per 2-5319(1). • • • • • • ~ • • • • • • • • • • ... • ,, __ _ Daylighting and Lumen Maintenance Controls (when applicable) · [ ) Uniformly iUumlnatlon reduction to on•half per 2-5319(e)1 • • • • • • • • • •. • • • • • • • • • __ _ [ ) Flicker free operation and no premature lamp failura per 2-5319(e)2. • • • •. • • • • • • • • • • • • • • • __ _ [ J 11me da~s to prevent unda1irablHydlng per 2-531 (e)3 • • • • • • • • • • • • • • • • •. • • __ _ [ J Srep switching devices with saparalion between on/off settings per2-5319(e)4 •••••••••••• ..._ __ Fonn Ravi1ed September 1986 MF-1 For Enforcement Agency Use Only Checked By Date Referenat in Consll'Uction Documents [ J Pholoe:811 sen10rs with a dffuslng cover and no opaque C/t:1t/flt per 2-5319(a)5 • • • • • • • • • • • __ _ [ I Man~s Instructions provided for installation and calibration per 2-5319(e)6 • • • • • • •••••• [ l Proe!'f' Installation of controls lncludng sensor location, certitioatlon of Initial cabbration and control of luminaires --- only within daylitarea per2-5319(e)8 ••••••••• __ _ [ ) Visible or audble malfunction alarm• per 2-5319(g) • • • __ _ Occupancy Sensing Devices (when applicable) [ ] Fljcker free operation and no premature lamp failure per 2-5319(e)2 • • • •. • • • • • ••••••• __ _ [ J rune·dalavs to prevent. undesireable cycllng par2-5319(a~ ••••••••••••• o ••••• __ _ [ J. Visible-or aucible malfunction alarms per 2-5319(g) ••• __ _ [ l limits on emissions per exceptions to 2-5319(e) • • • • ,..._ __ HVAC. and Rlumbing System Measures l ] Piping insutated as.required by-2-5312 •••••••• ,__ __ [ ] Certified HVAC equipment per 2-5314(a) • , , • • • • .__ __ .. [ ] Certified plumbing equipment per 2-5314(a) • • • • • • __ _ [ ] Heating.and cooling equipment efficiency per 2·5314{b) • __ _ [ ] Pilotless.lgnltlon of gas appliances per 2-5314(c) , • • , __ _ [ ] Automatlccontrols foroff-hours.per2-531S(a)1 ••••• __ _ [ ] ThEll"!'ostat set point requirements per 2-5315(a) •••• __ _ [ ) Sequential control of healing and cooring per 2-5315(a)3 ., __ _ [ I Automatic exhaustfan dampers per 2-53, 6(b) • • • • • __ _ [ J Thannostatcontrolsforeachzoneper2·:.;315(b) •••• __ _ [ ] Ventilation provided per 2-5316 and 2-5S.i3 • • • • • • .__ __ [ ] Heaters for domestic hot water and/or pools per 2-5318 • __ _ Page_ot_ Energy Budgets Worksheet WS-1A For Enforcement Agency Use Only \:1-AXNAk ¾ CD . Oocumentalion Aulhdr/F"um I?..-&. 3o /t>J cfieckedsy Date Summary Data Second Generation Standards Occupancy Types 1 Concltlonad Floor Area • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • f {p 3 {p ft2 2 Total AD owed Energy Use, • • • • • • • • • • • • • • • • • • •. • • • • • • • • • • • • • • • • • • • 2-'2.-"2..~°t b kB tu/yr 3 Energy Budget (Line 1 / Une· 2) • • • • • • • • • • • • • • • • • • •. • • • • • • • • • • • • • • • • • I 37 ~ kBtu/yr-ft2 Flrat Gen .. lfon Standard• Occupancy Types, 4-Cortcitlol18d Floor. Area. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • o • • ± tt2 5 Total Ala.wed Energy Use • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • kBIU/yr 8 Energy Budget (Line 5 / Line 4). • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • kBtu/yr-ft2 Second Generation Nonresidential Standards. A a· D E F G H J Conditioned Total Ughling Adjustment ~usted Allowed Cross-Sec-Concitloned Energy. Energy · Ene~ Occupancy Description/ tlonal Floor Area (:~:i, !Allowed LPD P~e A Col F -Col G Bud~t !Col IX I 0 Type, . Floor Number, Area of Story for Catagory (from CF-5) LPO Reqm. x 38.0 ColE +ColH (kBIU/yr) ()(:{::/(.C OFFtl-E.-ENnRi::. 4~·04 lit>~~ 1'3<a· ---13b 2'2-1.4Gl ,_ BL.\ 11..C> I Nt,. 1"2. "1"V 1)1 .t .a.1 TI t ~ : 13 1-'2.-i:: 9' If' :. ~-. ~4 GI c-ndJ . 110L!l io c;e·c;:-.... , li:>nv,E./) JJ li:IJ::'A .+-2 Ri:=~T ~no lo\~) 4~ !041.f'' .-'·1 I Total· l (,., 3'-, : Total Allowed Energy 2..'2-2.4qh First Generation Nonresidential Standards B C 0 e Energy Allowed Occupancy Oescriplion/ Floor (:=~-Ene'&; Type Floor Number Area· ColCx 10 N.A ' Total ' Total Fann Revited September 1986 Page_ot_ c;cJ R;;: ·zJJ . ~ 1.- b u1~ ~ ~C= ,1\ N 2..~)',.lfo:: ZONE I G-~'0$=» 3S?>'l --. (~U\'11:,. ~ WALL SF 8l.4 f<roF Bfo4 !,K.YL. ---01..fi'=>~ 24°8°::. 111- (.., µ.~~-,01 :t~\J\no, Rse>h ~ NST f1;.~I q~ WAl,...L l°t. 1--w, 2i;;1lo:. ONE "2--&Rlf::E> . ~u1-n;: C,J 'NAU-400 :iF 7fo 7 z_, ,COF 71.,, 7 . (;.LM,S 2-S0 o0 ::.. 200 t:.YL - ,Ila~ ,o• ..... :i:.NSl.l':"r°' ON ~ FLR. ~ uo -, Ne.,- T~\ 7A . WALl. wo-w, Z.Ot--\E. Gr~ SF WAt.L RooF ~L. &'-Ass ~.HEJG-Rf -Ne.,r FSt>~ WALL PER\ 2-oNc.. . e-~o;s WALL SF. R.OOF ;~ '(L. G-t...k>S ~-Hcl-'"Hr ~Df~ Nt:.T WAt.L >E. ll \ I M \G~B1cs Cois{:). E s 30,S )(.fl,,,~ i4 Y. ICo = 10~ se,i s 0 fY'= 4o - 4orp loo< ·40 -w, 10 f; -"'17, ·34i-w~ S-, lfo ::: -z.~ y/1.o: £>o '3~4 I 5ot;o= to - '2,0 'f.~ot" 40-V-../1 3&>1 :-w 2,.. \Nkt.,l.(,, I 2.. £)00/2---....-. w iOTAL 1s-s')( 11,,,::. 10 Q (loo '2--'t~ IS-Di I (1. IL>O WATTS -z_s ?..-I l,, Ct, o v-J/Sf 7--32.-v-1, \ oOO -'1\1-z__ _ 4a.-J.ooc-\ . q I "2-4'8-Wi. /2, T2- ?..O Y..., \fo •1-@ l(pO 3--v::> II $?L\ I@ loD WATT'S -2-'\0 1SDO ?-fo-w 1 vJ /6F I, g ~ -v-1.,_ \. ~(p . ~W-"'-'1-Y> ~ t)...oo("" Gf44 WATTS I w/sF WATTS w/sF I f?... He .1.oB n ... o 11, 4g \ I £\'' (,S-D \,$ CA4-ttu:.~ so'fqov Col>:: 7...,1 ~-=-8-1 aoo C.fM ,'12-§,/sF ,'331 PHI AV& f!-. = 2 ,ql\ HC=-3.3b 000 C~M Lv't 1/sf ,315 FW\ Av&-f?-= '2.,33 1-tC:=-4, I 1- C.FM ~~ Fwl M I. l Microbics Coro. DATE: 12-30-1987 AVERAGE R OF Wall -=----=---=------ Aw1 + Aw2 + Aw3 + Aw4 -------------------------------------------Aw1/Rw1 + Aw2/Rw2 + Aw3/Rw3 + Aw4/Rw4 AVERAGE HC OF Wall Aw 1 HCw.1. + Aw2HCw2 + Aw3HCw3 +· Aw4HCw4 Aw-1 · + Aw2 + Aw3 + Aw4- =============================================================================== 232.00 + 1000 .. 00 + 232.00 I 0.68 + Zone 1 AVERAGE R-VALUE 232.00 K 12 .. 00• + 1000 .. 00 /17.48 + 2.99 1000. 00, X 1 .• 43, + 40.00 + o.oo 40.00 / 1.50 + o.oo / 0.00 40.00 X 1.55 + 0.00 X 0.00 -----------------------------------~-----------------------~-------------------232;.00 + 1000.,00_ + z·o\"1e 1 AVERAGE. HC 3 •. 3'6· 240.00 + 684.00 + 240 .. 00 / 0.68 + Zone 2 AVERAGE. R-VALUE 684.00 /17 •. 48 + 2.33 240.00 X 12.00 + 684.00 X 1.43 + 240. 00 +· 684 .. 00· + Zone. 2. AVERAGE HC =· 4.12 40. 00 +· 0.00 20.00 + o.oo 20.00 / 1.50 + 20 •. 00 X 1.55 + 20.00 + o.oo Cooyrigh~ 1987 Mark Gallant-Haynal and Company 0.00 I 0.00 0.00 X 0.0() Envelope Summary Form and Worksheet (Part 1 ot 2) CF-2 ProJect Tide .. . ' ld:AYNA L $ Co, Documentation AulhotJFlnn Roof A Roof Type B Area· C Proposed R-value D Area/ R-value R-1 I /,, 7../.,, Z.B,S'Z.. S7,3b Total ,~'2.,{.,, Total 57 ,Sf,,, Average:R-value-J -z.6. 52! ColB/Col,D Glazingi in-Roof A B· C D Surface-Area·- Type· North East South Exterior Wall Area A B C D Surface Area NOf1h East South 784 5foB 7~~ Fonn Revised September 1986 E West- E West S-b2' For Enforcement Agency Use Only Checked By Date Exposed Floor Area/Soffits A Floor/Soffit Type Total F Horizontal Total F Total 7.Jo0f> B C D Area Proposed R-value Area/ R-value t--;A ,11 Total A~ge R-value ! AA ColB/ColD G H Total (At) Proposed U-value· Prorcsed· I\ A '} Page __ ot_ Envelope Summary Form and Wo.rksheet (Part 2 of 2) CF-2 ProJect1ide Ht8!'\Ak ~ Co. Documentation Author/Firm Opaque Exterior Walls and Doors A B C D E Surface-Area· Wd1 North East South West Type-(An) (Ae) (A1) (Aw)· W-1 3q7_ BO --\N -7_ -408 '?Of; s&S l:>Nl~ --too - .. Total, '3ft7 4BS ifo~ S'<oB Glazing· in Walls A B C D E Surface Area ~ G~. North East South W81t Type, (An) (Ae) (A1) (Aw) 6-l 3'12.-BO -- . '"b4 7... 80 -Total,. - Form Revi1ed September 1986 For Enfo108mentAgency Use Only Checked Sy Date F G H J. K · Prapoaed Wall -Requirement Total Heat A-Value R-Value (At) Capacity, (Rt) At/Rt (Rr) At/Rr 4"77_ f?.O • &lf,!J c.:,44,1 NA ~ A lbB4 f.43 n.~ Cj~.3 I r,,.,n I ,5..1:::; 1.50 M.O ~, 'It ?,7,1~ Total .B30,4 Total NA Propoaed Required ... WeightedAverage·R-Value f 2.. '2 7 f ColF/Coll I ~A I Col F/ Col K F G H J K ~Ing Characteristics Weighted Averages Total Total Area-WestArea Total Area (At), U-Value SC x U-Value xsc xSC ~TZ .. \.l .11 --- . 417-Total, --- U-Value West SC Total SC Average, I I · l I I · J I l Coll/ColF ColJ/ColE ColK/ColF- Page_ot_ Construction /\ssembfy Complianc~ Form CF-3 . Prciect Tida • . For Eif ~ment Agehi;y Use Only "AYNAk 'taJ. OOQlfflantadan AulhorlFJnn Daw General Information 1 A11amb'1 Type and Number-~ • • • • • • • , • • , , • • • • • • • • • • , • • . • • • • • • • , , , , WA LL i,. \ 2, Framing Type • • • • • • • • • • • • • • • • • • • • • • • • • • • , • , • ., • , • o • • • o • • , ?eW k • 3 Fnuning1SIZ8' • • • • • • • • • • • • Ill • • • • • • • • • • • • • • • • • • • • e Cl • • • • • • • • • ._ __ N=A~- 4 Framing,, Spacing •. • • -~ • . • • • • • • • • 0 • • • • • • • e • • • • • • • • • • • • 0 • • • • • • • tJ A lnchaa Data 5 lnauladon In Cavity • • • , • , • • • • , • • , , • ,. , , , • • • • • , • • • • • • • • • • • • • • · • F-lt2-hr/8tu 6 EHecdva,R•vaku1.ol Cavity/framlng.r. • • • • • • ·• • • • • • • • • • • • • • , , • • • • • • • • • •. • -F-tt2-hr/Btu " 0 ' .. '(;: .. '. . t, ... 0: . . Sketch of Construction Assembly List of Construction Components A a: C D e Wal, sf::dlio HO wew HI Cole xCol D DeaGipdon A-value, (lbll ) (BtulF-lb) (BIUIF-11) 1 ~otJ~1 ,11.:-~u~ -(e11 • G.>& <.r;o •'2. 1-Z.o 2 3 4, 5 6 7 IJ Tolll·R-VaJut w/o lllma,. • • , .. , • •· . . • • • •. ·&.,8 focal HO IZ..o i In aide aurfac:e air lilnl , • • ·• • • • • • • • • • • • .bS 10 Ou11ide ,u,tac;e aJr file· • , , , , , • • , • , , • • , ·l ~ 11 Toral lh1Hmal· reaf1tance (At) • • • • • • • • • • • • 1 .. sJ 12 U-valua· (1 / LIM· 11) • • ·· • • • • • • • • • • • , • • .,s; ~ C"'' • ., • 1 f'" .-... , Page ot -- Construction Assemb~y Complianc~ Form CF-3 Project nils For Enforcement Agency Use Only I \-\P.. '( NAl-+ co . Documentation Author/Finn · Date Checked By Date General Information Assembly Type and Number ••••••••••••••••• a • • • • • • • • • • • • • • • • • • • WALL :i:t="2,... 2 Framing Type. • •. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • W 00 P 3 Fran1ing Size • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • o • • • • • • • • • • • • • 2..,..c... Co 4 Framing, Spacing, • • • • • • • • • • • • • • • • • • • • • • • • • • • " • • • • • • • • • , • • • • \ (e11 inches 5 Insulation in Cavity • • • • • • , , , , • • , • • , , • • • , • • , , • • • • • • • • •. • • • • , • · • I '1 F-ft2-hr/Btu 6 Effective R-value of Cavity/Framing· • • • •. • • • • • • • • • • • · • • • • • • • • • • • • • • • • ·• • • \ (p • '3 (p F-lt2-hr/Btu Sketch of Construction Assembly List of Construction Components 2 3 4 5 6 7 11 De1crfptlol1'·· '?/e, t-i':i'f=: '20Af2::D 8 Total R-Valuew/o films •••••••••••••• a R-value, (1.'5~ /1.42' 9 Inside· surface air film • • • ·• • • • • • • • • • • • __ ._ep_f3_ 10 Outside surface air file • • • • • • • • • • • • • • • __ ._1_7 ___ _ 11 Tola! lhennal resistance (Rt) • • • • • • • • • • • • I t3 • 3 3 12 U-value (1 / Una. 11) •••••••••••••••• . ~z+ Fonn Revised September 1986 C Wal Welaht {lbllt2) .4:1 D Specific Heat (Blu/F-lb) Tola! HC e HC Cole xCol o (Btu/F-sf) •Cc,8 • (!;)-, 1.43 Page_ot_ Construction Assembly Complianc~ Form Project Tide HA,JAL-4,c.,o Oocume.ntalion Author/Finn General Information Data CF-3 For Enforcement Agency Use Only . \· Checked By Date 1 Assembly Type and Number· ~-, • , , , , , , • • • • , .. , • • • • • • • • • • • • • • • • • • • • • we:::::\::::) 6 2 Framing Type • • • • • • • • • , • • •. • • • • • • • • • • • • • • • • • • • • • • • • • •. • • • • 00 3 Frmning.Slze, ••••••••••••• i •••••• I •••• 0 e O •••••••••••••••• 2:P:c., I -z,... 4 Fnuning Spacing· • • • • • • • • • •. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • -i-4 5 Insulation In Cavity • • • • • • • • • • • • • • • • • • •. • • • • • • • • • • • • • • • • • • • • • · • · 30 6 Effectlve.R-valuaofCavity/Framing •• , •••••••• JI}~'¥='. ~-.3, •.•••••••••••••• 2.h,32 inches F-ft2-hr/Btu F-ft2-hr/Btu Sketch of Construction Assembly List of Construction Components 2 3 4 5. 6· 7 Oeacrlptlon ~tJ I k-1-l H-:7 !'200 fl t:Jf:,J ,12-·· PL:r Wool? I I z 11 AULl~:[ll-A L Tl L.E- B R-value c;:J. 8;2 8. Total R-Value. w/o films-. • • • • • • • • • • • • • 2-S , $ 2. 9· Inside surface air film. • • • ·• • • • • • • • • • • • · 0 • (p I 10 Outsidesurface air file • • • • • • • • • • • • • • • 0 • I] tt Total thennal·reslstanc:e-(Rt). • • • • • • • • • • • 1-'f , '?>Q 12 U-value (1 I Une 11) •••••• , •••••• , • , (~ ~0 34 Fonn Revised September 1986 C wan We' ht (lb/~ D s ciffc -!:at (BtUIF-lb) Total HC e HC Cote x-Col o (Btu/F·sf) Page_of_ HVAC Power Indices Summary Form and Worksheets CF-4 For Enforcement Agency Use Only Pl'OJect Tiue MYNAL ~ Co . Documentation Author.1 I '1--('3o /8 7 DaiJ Checked By Date Summary Data 1 Candtioned Floor Area • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ___ 8/g ',_ _ _ ft2 2 Total Fan Watts During Peak Cooling Conditions (from Worksheets below) • • • • • • • • • • • • • • • • -~ kilowatts 3 Fan Wattage Index (Une 2 x.1000 / Une 1) • • • • • • • • • • •. • , • , , • • • • •. • • • • • • • • • • • 3 3 \ Watts/ft2 4. Total HVAC System Energy During:Peak Cooling Conditions (from Worksheets below) • • • • • • • • • • • 31 , "74 kBtulhr 5 Cooling.Power Index (Line 4 x.1000 / Une-1) • , •• , , ••••••• , • • • • • •. • • • • • • • • • • 3fo, 5'8 BIUJhr-ft2 6. Total HVAC System Energy During Peak Heating Conditions (from Worksheets below) • • • • • , • • • • • '2.-°I , J 1 7 Heating Power Index (Line 6 x 1000 / Une· 1) • • • • • • , , • • • • • • • • , • • , • • • • • • • • • • :ij:, 2--'o kBIUJhr Btulhr-ft2 Fan Energy A B C D E F Brake Horsepower Motor x Drive Efficiency Equipment Mark /"_11,,, D8Tplion ~\E Cooling: Heating Cooling Heating. l-4P-A ~DY{) 02..4 '.510 . I "11 -f.,,.Oo/n - i=:~-I l=' .. :V.1-1-..6. I ~e,,-r ,::,Al\\ 43w --- : - Heating and Cooling Equipment A B C D E F Cooling Equ~ent Design Conversion Source· Description Output Efficiency Factor kBtulhr na All Fans .04'5 na--. 10.239 .44 From Worksheet Above· \-1-P-A ~O'f D 07-4 310 -z,.4. R ttP:n 9.1 r;;r;;Q ,0.2:?f\ 31.3S Total '3\.7~ Fonn Revised September 1986 . G· H J Peak kilowatts Conversion Number Factor Fans Cooling Heating 0.748 I ,1A.c; -~ I ,043 0.748 0.748 0.748· 0.748, 0.746 0.746· 0.746 Total kilowatts . Z..f3i? - G H J Heating Design Conversion Source Output Efficiency Factor kBtulhr • /J47-na 10.239 .44 i;/A,41C.Rrr ?.i COP 5,0 2'1,33 Total '2.""l,71 Page __ ot __ HVAC Power Indices Summary Form and Worksheets CF-4 For Enforcem~tAgency Use Only ProJect Tiui H:AYNAL ~ ('o Documentadon Authot I -i-/30 /-8 7 Datd, Checked By Date Summary Data 1 Condtloned Floor Area· • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 7 /.e, 1 · tt2 2' Total Fan Watta, During Peak Cooling Conditions (from Worksheets below) • • • • • • • • • • • • • • • • • , 2-B?J kilowatts 3 Fan Wattage Index (Une 2 x 1000 I Une·1) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 37 S: Wattslft2 4 Total-HVAC System Energy During.Peak Cooling. Conditions (from Worksheets below) ••••••••• , • 31 , 1') kBtu/hr 5. Cooling.Power Index (Line 4,x, 1000 / Une-1) •••••••••• , ••••••••• , •• , , , •• , , 4 \. 1:5 etulhr-ft2 6 TotalHVAC System Energy During Peak Headng,Condidona·(fromWorksheets below). • • • • • • • • • • 'Z-4 ,]1 kBtulhr 7 Headng.Power lndeit(Une 6 x 1000 / Une 1) •••••••••••••••••••••••• , ••••• 3.g • e> I Btu/hr-ft2 Fan Energy A B C D E F· G H J Brake-Horsepower Motor x Drive.J;lflclency Peak kilowatts Equipment ~ Heating Conversion Number MBl'k De~ptlon Cooling Heating_ . Cooling. Factor Fans Caollng Heating C,oc~~\E HF>-B 5D'lD02..4~1() . I "11 -(,,,0°/r. -0.746 l • i_A.~ -i=_i::-I ,:;_'V.LlA•J,:,,.-r-f:.AM 43"'1 ---~ 1 M-3 - 0.746 0.746 0.746 0.746 -0.746 0.746 0.746· Total kilowatts . Z.t3~ - Heating and Cooling Equipment A B c. D E F G H J Cooling Heating Equipment Design. ·conversion Source Design Conversion Source Mad< Description Output Efficiency Factor kBtulhr Output Efficiency Factor kBtu/hr na. All Fans . 043 na 10.239 .44 . 047-na . 10.239 .4.::\ From Worksheet Above, 1-\P-1?:i SO't 0024310 -z..4.8 ~Pm . a.1 c;r::12 10. 23'\ 31.35 71 .... +(Rn 2.:1 U>P 5,0 '2.C\ .3.?i l To~I 3\.7~ Total '24.71 Fann Revised September 1986 Page_of_ ProJect Name: Microbics Corp. Documenta·tion Author :. Haynal. and Company Da-te :: December 30 ~ 1987 BRAKE HORSEPOWER CALCULATION· Total CFM x Static Pressure BHP· = -------------------------------- Stat~c E££iciency. x 6356 800 x .62S HP-A~·& TYPICAL.:: BHP· =--------------------= .19·7 0 ... 4 x· 6356 Lighting Summary and Worksheet (Part 1 of 2) CF-5 Pro¥.J lite" Bl C$ Co R:P ' Documentation Author/Firm Proposed Adjusted LPD 1 Total Building.Watts (CF-5) •••••••• 2 Control Credit Watts (WS-58) : • • • ~ • 3 · Adjusted Watts (Una 1 -Una 2) • • • • • • 4 Conditioned Floor Area. • • • • • • ·, • • 5 Adjusted LPO (Une,3"/ Une4) , ••••• 311.oO Watts. -Watts 3. l bO Watts. 1 lo3b tt2 I· ,:)3 Wattstft2: llluminance Categories G, H, and I A B-C Luminaiw Reference In Reference Construclion Coda Documents· Luminaire Description: 3 OF '9 2.~ 4 4-TI 1 B~ CLune. For Enforcement Agency Use Only Checked By Date Tailored LPD Approach (when applicable) 1 Watts for IC: A -DIE (WS-5C) , • • • • • 2 Task Watts for IC: E & F (WS-SD) , , , , 3 Non-Task Watts for IC: E & F (WS-50) • , 4 Task Watts for IC: G, H & I (WS-SE) , , , 5 Non-Task Watts for_lC: G, H &.I (WS-SE) • 6 Retail/Wholesale Store Ughtlng (WS-SF) • 7 Total Allowed Watts (lines 1-6) •••••• a-Conditioned Floor Area • • • • • • • • • 9 Maximum LPD (Line 7 I Line 8) • • • • • • 0 E Number of Watts per Luminaire Luminaires (incl. ballast) I " l~O ~A ' F Watts Watts Watts Watts Watts Watts Watts tt2 Watts/ft2 Total Watts '3040 tJ O \.l\l l:"-1/' .A. Al I'\ , ( t:?t::t:.T J?.Ml;) . :,_ /,,.,Q l1-0 ·- Page Total 3.1 foo Building Total 31 b O Form Revised September 1986 Page_ of_ ****** SCM ENERGY ANALYSIS MODEL VERSION 2.0F ****** ***· 2ND GENERA·TION NONRESIDENTI.AL ENERGY STANDARD *** ***************************************************** FILE NAME BUILDING TYPE BUILDING TITLE AREA (SQ.FT.) ************* :· MICROB1 : OFFICE PRIMARY DATA ************ : MICROBICS CORP -ZONE 1 <SUITE B> EXTERIOR WALL•••••••••••••••••••••••••••••••••••••••• W-INDOW. :-NORTH/NORTHEAST' ........ ., •••••••••••••••••••••• ROOF t EAST /SOUTHEAST'••••••••••••••••••••••••••••• t SOUTH/SOUTHWEST••••••••••••••••••••••••••••• : WEST /NORTHWES,T ., ••• , .......................... •<-• ... . ························----~·-·-········--···~·· GROUND FLOOR•••-•••••••• .. ••••••~•••••••• .. •••••••••••• . TOTAL CONDITI.ONED· FLOOR •.•• ., .................................. ,. -• 'R' -VALUE <EXCLUDING' FILM· RES-ISTANCES> ************************************** DATE: 12-30-1987 TIME: 16:24:37 PAGE: 1 1272. 1'32 40 0 0 869 869 869 WALLS ............ ~ ...................................... 2.99 WINDOW <INCLUDING INSIDE FILM RESISTANCE) •••••••••••• .74 ROOF ................................................... 28.52 FLOOR ...................................................... 0 HVAC SYSTEM ***********' HEATING EQUIPMENT TYPE ................................ . COOLING EQUIPMENT TYPE ................................ . ECONOMIZER •••• , ............................................... , ....... . FAN POWER· <WATTS/SQ .. FT •. > ..................................... . AIR CIRCULATION RATE CCFM/SQ.FT.) •••••••.••••••••••••• OTHER ***** HEAT PUMP AIR CONDITIONER NO • 331 9 •::, • s;;;. AZIMUTH OF NORTHERN BUILDING ORIENTATION ••••••••••••• O SHADING COEFFICIENT~••••••••••••••••••••••••••••••••• .71 HEAT CAPACITY OF EXT. WALL <BTU/F-SQ.FT.) ••••••••••~• 3.36 LIGHTING LEVEL (WATTS/SQ.FT.) •••••••••••••••••••••••• 1.'31 FLOOR TYPE••••••••••••••••••••••••••••••••••••••••••• SLAB CL I'MATE Z.ONE ••••••.••••.•••••••• -• • • • •. • • • • • • • • • • • • • • • • • • 7 ****** SCM ENERGY ANALYSIS MODEL. VERSION 2.0F ****** *** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARD***· ***************************************************** PHYSICAL PARAMETERS ******************* SECONDARY DATA ************** DATE: 12-30-1987 TIME: 16: 24:39 PAGE: 2 DOOR AREA (SQ.FT.) •••••••••••••••••••••••••••••••••••••••••• 40 DOOR ~R~-VALUE <EXCLUDING F1LM RESISTANCES) ••••••••••••••••• 1.5 WALL ABSORPTIVITY••••••••••••••••••••••••••••••••••••••••••• .7 ROOF ABSORPTIVITY••••••••••••••••••••••••••••••••••••••••••• .7 CEILING HEI'GHT (FT-. ) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •. • • • • •. • • • • • 10 SHADING ******* SHADING COEFFICIENT: NORTH/NORTHEAST•••••~••••••••••••••••• .71 t EAST /SOUTHEAST ............................ 71 i SOUTH/SOUTHWEST·~••••••••••••••••••••• .71 :-WES·T /NORTHWEST ... ., •. •. • •. • .. • • • • • • •. • .. • •. • • • • •. 71 --------" ~ DOES TH rs. BU I'LD I NG HAVE w I NDOW· OVERHANGS •••••.•••••• •· • • • • • • • • NO DOES THI-S-BUILDING HAVE WINDOW SIDE-FINS u, •.•••................. NO MECHANICAL AND ELECTRICAL ************************* RATED HEATING' EFFICIENCY ......................................... ., • .,. • • 2. 7 RATED COOLING EER .............................................. 8.100001 WATER HEATER TYPE ................................................ ELECTRIC SPECIAL FEATURES ****************· DAYLIGHTING STRATEGIES ........... .,, ............ •-·•.......... •. •. .. • • • • • • • • NO SOLAR WATER HEAT1NG SYSTEM ................ ~•••••••••••••••••••• NO ****** SCM ENERGY ANALYSIS MODEL VERSION 2.0F ****** *** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARD*** ***************************************************** DATE: 12-30-1987 TIME: 16:24:41 PAGE: 3 SCHEDULING ********** FIXED DATA ********** OCCUPANCY LEVEL FOR OPERATIONAL. PERIODS <FRACTION) : DAY • • • •· ~ e• • e • • • m ••mm m • • • • • • • • : NIGHTS •••••••••••••••••••••• AVERAGE LIGHTING AND RECEPTACLE LEVEL FOR OPERATIONAL PERIODS (FRACTION) :DAY PERIOD ........... . :NIGHT PERIOD ••••••••• EQUIVALENT OPERATIONAL. HOURS PER YEAR :LIGHTING (DAYS) ••.•••• : LIGHTING <NIGHTS) •••• :RECEPTACLE ••••••••••• :.FANS •.•.•• -~ .............. . • 546 • 038 • 703 • 144 2915 359 3274 4518 :.WATER HEATER • • • • • •. • • • 1 770 NUMBER OF NON-OPERATIONAL HOURS. PER WEEK DAY PERIOD •••••••••••••••••w~•••••••~·~•••••••••••••••• 32 N.-I.GHT PER I.OD ........ •1 ...... ~ •• , -~ r. ....................... •-• • • • • • •. • • • • 46 NUMBER OF HOLIDAYS DURING HEATING ~SEASON •.•. ,.,.... •. • •. .. • • • • •. • • • • • • 6 NUMBER OF HOLIDAYS DURING· COOL.ING· SEASON ............... " ••••••••. 2 SET-POINT TEMPERATURE CF> : WINTER •••••.•.•••••.•• •-r..r• •. • • • • • • • • 70 PHYSICAL PARAMETERS ******************* r WJNTER SETBACK •••~••r••••••••••• 40 :t SUMMER ......... , • • • • • • • • • • • • • • • • • • • 78 :, SUMMER SETUP' • • •. .. • • • • • • • •. • • • • •. • • • 85 INSIDE FILM RESISTANCE: WALLS ............ ~•••••••••••••••••••• .68 ~ROOF••••••••••••••••••••••••••••••• .76 :: FLOOR • • •. ... • .. • •. •. •. • • •. • • • • • • • • •. • • • • • • • • • 76 INFILTRATION· RATE. DUR.ING NON-OPERATIONAL HOURS <CFM/SQ •. FT •. > •• 0284 SLAB FLOOR· ''U'' -VALUE < BTU/HR-SQ· .. FT. -F> .. • •. • • •. • • .. • • • • • • • • • • • • • • 0862 INTERNAL LOADS AND ENERGY *************************"" RECEPTACLE PEAK LOAD <WATTS/SQ.F~} •••••~••••••••••••••••••• .5 WATER HEAT ING. < BTU/SQ. FT •. /YEAR·> • • • .. • • • • • • • • • • • • • • • • • • • • • • • • • 64 PEOPLE SENSIBLE LOAD <BTU/HR/PERSON>·•••••••••••••••••••••••• 230 PEOPLE LATENT LOAD (BTU/HR/PERSON> •••••••••••••••••••••••••• 190 AREA· PER PERSON (SQ. FT •. /PERSON) • • • • • .. • • • . • • . •. • • • • • • • • • • • • • • • 250 ******* SCM ENERGY ANALYSIS MODEL VERSION 2.0F******* *** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARDS*** ****************************************************** DATE: 12-30-1987 TIME: 16:24:56 PAGE: 4 : 7 : MICROB1 CLIMATE ZONE BUILDING FILE BUILDING TYPE BUILDING TITLE: : OFFICE MICROBICS CORP -ZONE 1 (SUITE B) BALANCE-POINT TEMPERATURES AND DEGREE-DAYS INPUT -----------=------===------=--===-----==-------- DAY NIGHT ------------------------------BPT1 = 59.73 BPT1 = 68~39 BPT2 = 66.98 BPT2 = 76.49 BPT3 =, 66 .. 98' BPT3 = 76.49 HOO = 294.,43 HDO = 3396.50 CDD =· 370 •. 71 CDD = ENVELOPE HEAT TRANSFER FACTORS <BTU/HR-F> ============= =========================== OVERALL BUILDING ENVELOPE HEAT TRANSFER RATE '<WINTER> OVERALL .HEAT TRANSFER FACTOR 'K' (W.IN,TER> OVERALL BUlLDING: ENVELOPE HEAT TRANSFER RATE <SUMMER) OVERALL HEAT TRANSFER FACTOR' 'K'' (SUMMER> HEATING COOLING ·-ANNUAL LOADS <-MBTU'· S-> ===================== ANNUAL SITE. ENERGY REQUIREMENTS <MBTU'S> ======================================== SITE HEATING SITE COOLING SITE LIGHTING SITE RECEPTACLE SITE FAN, SITE HOT WATER o.oo ANNUAL SOURCE ENERGY USE ESTIMATE <KBTU/SG!.FT.) =============================================== SOURCE HEATING SOURCE COOLING SOURCE LIGHTING SOURCE RECEPTACLE SOURCE FAN SOURCE. HOT WATER 594.4 1109.5 600.6 1075.0 8.7 7.4 3.5 5.8 18.5 4.9 4 .. 4 0.4 12.2 20.0 64.0 16.8 15.3 1. 4 ====================================================================== ANNUAL SOURCE CONDITIONING ENERGY USE ANNUAL SOURCE ENERGY USE ESTIMATE IS 47.5*1.027= 48.8 KBTU/SQ.FT. 130.9 KBTU/SQ.FT. ====================================================================== < NOTE: 1 KWH = 10.-239 KBTUS OF SOURCE ENERGY > ****** SCM ENERGY ANALYSIS MODEL VERSION a.OF****** *** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARD*** ***************************************************** FILE NAME BUILDING TYPE, BUILDING TITLE AREA <SQ.FT.) ************* :., MICROB2 : OFFICE PRIMARY DATA ************ : MICROBICS CORP. -ZONE 2 <SUITE C) DATE: 12-30-1987 TIME: 16:25:45 PAGE: 5 EXTERIOR WALL•••••••••••••••••••••••••••••••••••••••• 944 WINDOW :: NORTH/NORTHEAST ..................... , • • • • • • • • •. • • • • 200 : EAST /SOUTHEAST••••••••••••••••••••••••••••• 40 ~SOUTH/SOUTHWEST ................................ 0 : WEST. /NORTHWEST • •. •. • • •. • •. • •. • • • • • •. • • •. •. • • •. • • • • • • O ROOF ................ ~ •••• ~ ............. ~ .................... 767 GROUND FLOOR ........ ~••••~--·~••••••••••••••••••••••••• 767 TOTAL CONDITIONED FLOOR •• F ............................... 767 'R'-VALUE (EXCLUDING· FI:LM RESISTANCES) ************************************** WALLS ............................... , ........................ , •. • • .. • • • •. • • • 2. 33 WINDOW <INCLUDING INSIDE FILM RESISTANCE> •••••••••••• .74 ROOF ..................................................... 28.52 FLOOR ...................................................... 0 HVAC SYSTEM *********** HEATING EQUIPMENT TYPE ............................................ HEAT PUMP COOLING EQUIPMENT TYPE ................................. AIR CONDITIONER ECONOMIZER ................................................ NO FAN POWER (WATTS/SQ.F~) .................................. 375 AIR CIRCULATION-RATE (CFM/SQ. FT. > • • • • .. • • • • • •. • • .. • • • • • • 1. 04 OTHER *****' AZIMUTH OF NORTHERN BUILDING ORIENTATION ............... 0 SHADING COEFFICIENT ....................................... 71 HEAT CAPACITY OF EXT. WALL (BTU/F-SQ.FT.) .............. 4.12 LIGHTING LEVEL (WATTS/SQ.FT .. ) •••••••••••••••••••••••• 1.96 FLOOR TYPE ........ ~••••••••••••••••••·•••·--·--···••••••• SLAB CLIMATE ZONE••••••••••••••••••••••••••••••••••••••••• 7 ****** SCM ENERGY ANALYSIS MODEL VERSION e.oF ****** ***· 2ND GENERATION NONRESIDENTIAL ENERGY STANDARD*** ***************************************************** PHYSICAL PARAMETERS ******************* SECONDARY DATA ************** DATE: 12-30-1987 TI ME: 16: 25: 4 7 PAGE: 6 DOOR AREA CSQ.F~) ••••••••••••••••••••••••••••• ~ •••••••••••• 20 DOOR 'R'-VALUE <EXCLUDING FILM RESISTANCES}••••••••••••••••• 1.5 WALL ABSORPTIVITY •••••••••••••••••••••••••••••••••••••••••••• 7 ROOF ABSORPTIVITY •r••••••••••••••••••••••••••••••••••••••••• .7 CEILING HE'IGHT (FT.> • • • • • • • • • • • • • •.• • • • • •. • • • • •.• • • • • • • • • • • • • • • 10 SHADING ******* SHADING COEFFIC1ENT: NORTH/NORTHEAST••••••••••••••••••••••• .71 ~EAST/SOUTHEAST••••••~•••••••••••••••• .71 ~SOUTH/SOUTHWEST•••••~••••••••••~•••••• .71 ~WEST/NORTHWEST ......................... 71 DOES THIS BUILDING HAVE w.INDOW OVE;RHANGS • .. • •. • •. • • • .. • • • • • • • • • • NO DOES THIS BUILDING HAVE WINDOW SIDE-FINS •••.••••.••••••.•••••••. NO MECHANICAL AND ELECTRICAL ************************* RATED HEATING EFFICIENCY•••••••••~•••••••••••••••••••••••••• 2.7 RATED COOLING EER ••••••••••••••••••••••••••••••••••••••••••• 8.100001 WATER HEATER TYPE ............................................ ELECTRIC SPECI'AL FEATURES ****************· DAYLIGHTING STRATEGIES .......................................... NO SOLAR WATER HEATING SYSTEM .......................... ~•••••••••• NO ****** SCM ENERGY ANALYSIS MODEL VERSION 2.0F ****** *** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARD*** ***************************************************** DATE: 12-30-1987 TIME: 16: 25: 49 PAGE: 7 SCHEDULING ********** FIXED DATA ********** OCCUPANCY LEVEL FOR OPERATIONAL. PERIODS (FRACTION) : DAY ••••• ,. a ••••• a. a, a a a a D a a a a a i NlGHTS •••••••••••••••••••••• AVERAGE LI"GHTING AND RECEPTACLE LEVEL FOR OPERATIONAL PERIODS (FRACTION> :DAY PERIOD ••••.••••••• :NIGHT PERIOD ••••••••• EQUIVALENT OPERATIONAL HOURS PER YEAR :LIGHTING <DAYS) •••••• :LIGHTING (NIGHTS> •••• ,RECEPTACLE ••••••••••• :FANS ••••••••••••••••• :WATER HEATER ••••••••• NUMBER OF NON-OPERATIONAL HOURS PER WEEK DAY PER10D ••••••••• · ••••••••••• w••~••••••••••••••••••••• • 546 • 038 • 703 • 144 2915 359 3274 4518 1770 32 NIGHT PERIOD••••••••••••••••••••••••••••••••••••••••••• 46 NUMBER OF HOLIDAYS DURI:NG HEAT INS ·sEASON •. • • • •. • • .. • • • • • •. • • • •. • • 6 NUMBER OF HOLIDAYS DURING" COOL INS SEASON ., • •. • • • •. • • • • • • • • • • • • • 2 SET-POINT TEMPERATURE CF> : WINTER•••••••••••••••••••••••••• 70 PHYSICAL PARAMETERS ******************* :. WINTER SETBACK • •. • • •. • • •. • • • • • • • • • • 40 : SUMMER•••••••••••••••••••••••••• 78 : SUMMER SETUP•••••••••••••••••••• 85 INSIDE FILM RESISTANCE: WALLS •••••••••••••••••••••••••••••.. 68 :·. ROOF .• • •. • •. •. • • • • • • • • • • • • • • • • • • • • • • • • • • 76 :· FLOOR •••••••• , • • .. • • • •. • • • • • • • • • • • • • • • .. 76 INFI"LTRATION RATE DURI.NS NON.-OPERATIONAL HOURS <CFM/SQ. FT •. ) •• 0284 SLAB FLOOR ,. U' -VALUE <BTU/HR-SQ. FT. -F> • • • •. • • • • • • • • • • • • • • • • • • • 0862 INTERNAL LOADS AND ENERGY *************************' RECEPTACLE PEAK LOAD CWATTS/SQ.F~) ••••••••••••••••••.••••••• 5 WATER HEATINS <BTU/SQ.FT./YEAR> ••••••••••••••••••••••••••••• 64 PEOPLE SENSIBLE LOAD (BTU/HR/PERSON> •••••••••••••••••••••••• 230 PEOPLE LATENT LOAD <BTU/HR/PERSON> •••••••••••••••••••••••••• 190 AREA PER PERSON (SQ.FT./PERSON> ••••••••••••••••••••••••••••• 250 ******* SCM ENERGY ANALYSIS MODEL VERSION 2.0F******* *** 2ND GENERATION NONRESIDENTIAL ENERGY STANDARDS*** ****************************************************** DATE: 12-30-1987 TIME: 16:26:05 PAGE: 8 . . 7 : MICR0B2 CLIMATE ZONE BUILDING FILE I:3UILDING TYPE BUILDING TITLE :· : OFFICE MICROBlCS CORP. -ZONE 2 <SUITE C) BALANCE-POINT' TEMPERATURES AND DEGREE-DAYS INPUT ================================================ DAY NIGHT ------------------------------BPT1 -59.50 BPT1 -· 68.34 BPT2 =· 66.57 BPT2 = 76.42 BPT3 = 66.57 BPT3 = 76.42 HDD = 276.92 HOD = 3379.95 COD -404 .. 86 COD - ENVELOPE HEAT TRANSFER FACTORS <BTU/HR-F) ========================================= OVERALL BUILDING ENVELOPE HEAT TRANSFER RATE (W-INTER) OVERALL HEAT TRANSFER FACTOR ''K' <WINTER> OVERALL. BUILDING· ENVELOPE. HEAT TRANSFER RATE (SUMMER> OVERALL HEAT' TRANSFER FACTOR ,,_K, (SUMMER) HEATING COOLING ANNUAL. LOADS· ( MBTU' S > =====================· ANNUAL SITE ENERGY REQUIREMENTS <MBTU'S) ======================================== SITE HEATING SITE COOLING SI.TE LIGHTING SITE RECEPTACLE SITE FAN SITE HOT WATER 0.00 ANNUAL. SOURCE ENERGY USE EST'IMATE CKBTU/SQ. FT.> --m------=-=---=---=----------------------=----SOURCE HEATING SOURCE COOL.ING. SOURCE LIGHTING SOURCE RECEPTACLE. SOURCE FAN SOURCE HOT WATER 555.5 1010.2 561.9 980 •. 7 7.7 7.3 3. 1 5.7 16.8 4.3 4.4 0.3 1 ,::, ,::, ....... 22.4 65.7 16.8 17.3 1. 4 =========================================== ·========================== ANNUAL SOURCE CONDITIONING ENERGY USE ANNUAL SOURCE ENERGY USE ESTIMATE I.S 52.0*l.027= 53~4 KBTU/SQ.FT. 137.2 KBTU/SQ.FT. ====================================================================== ( NOTE:· 1 KWH = 10. 239 KBTUS OF SOURCE ENERGY > ******* SCM ENERGY ANALYSIS MODEL VERSION 2.0F******* *** 2ND GENERATION NONRESIDENTIAL. ENERGY STANDARDS*** ****************************************************** HEATING COOLING ANNUAL. LOADS (MBTU'S) ANNUAL SITE ENERGY REQUIREMENTS (MBTU'S> ======================================== SI.TE HEATING SITE COOLING s·ITE LIGHTING SITE RECEPTACLE SITE FAN SITE HOT' WATER DATE: 12-30-1987 TIME: 16:.26: 15 PAGE: 9 35 .. 3 9.1 8.9 0.7 ANNUAL SOURCE ENERGY USE ESTIMATE CKBTU/SQ.FT.) =============================================== SOURCE .. HEATING SOURCE COOLING SOURCE LIGHT'ING SOURCE RECEPTACLE SOURCE FAN SOURCE HOT WATER 12.2 21.1 64· .. 8 16.8 16.3 1. 4 ===========-========================================================== ANNUAL SOURCE CONDITIONING ENERGY USE ANNUAL SOURCE ENERGY USE ESTIMATE IS 49.6*1.027= 50.9 KBTU/SQ.FT. 133.9 KBTU/SQ.FT. ====================================================================== < NOTE~ 1 KWH= 10.239 KBTUS OF SOURCE ENERGY> 06/10/85 CENTRAL AIR CONDITIONERS --------------------------------------------------------------------------------------------------------------------------------------------------------------I DESCRIPTION OF HODEL I COOLING I TEST INFORMATION! HEAT PUMP HEATING I -------------------------------------------------------·----------------------------------------------------------------------------------------------------A V I 47 DEGREES I 17 DEGREES* R C 0 COOL- --------------------------------------------I B N L p COOL-ING ELEC-CALC HEAT-HEAT-TC RC -C T H ING ~LEC-CAPA-TRICAL. CD HEAT ING ELEC-A ING ElEC-D y 0 AO COMPRESSOR NOH-COMPRESSOR u A A CAPA-,TRICAL CITY INPUT OR SEAS CAPA-TRICAL STAND C CAPA-TRICAL I p D N D MODEL NUflBER HODEL UUl18ER F G s CITY IHPUT AT 82 AT 82 0.25 PERF CITY INPUT BY 0 CITY INPUT R E E DE (CONDENSING UNIT) ( SPLIT SYSTEM ONLY). R E E BTUH WATTS EER SEER l<BTUH (KW> OPT. FACT BTUH WATTS WATTS p BTUH WATTS COP? ----------------------.---------------------------------------------------------------------------------------------------------------------------------------2S CR 50QT11830 230 1 17000 2280 7.S 8.00 18.50 2.30 .05 5.6 16700 1940 0 2.s 10000 1650 1.7 Y 25 CR 50QT12430 208 1 23800 3095 7.7 8.00 25.60 2.95 .16 6.2 24000 2800 0 2.5 14000 2200 1.8 Y 25 CR SOQT12430 230 1 23800 3095 7.7 8.oo 25.60 2.9S .16 6.2 24000 2800 0 2.S 14000 2200 1.8 Y 25 CR 50QT13030 208 1 27600 3680 7.S 8.00 31.10 3.!,S .11 6.0 28400 3200 0 2.6 17200 2800 1.8 Y 25 CR 50QT13030 230 1 27600 3680 7.5 8.00 31.10 3.65 .11 6.0 28400 3200 0 2.6 17200 2800 1.8 Y 25 CR 50YQ02431 230 1 24800 3080 8.1 7.90 26.95 2.98 .25 S.9 26400 2790 40 2.7 13500 2353 1. 7 Y 25 CR SOYQ03031 z30 1 zMoo 3580 e.1 8.35 32.00 3.41 .zr 6.o 3o4oo 3087 4o 2.8 15000 2598 1.7 Y 25 CR 50YQ03631 230 l 34000 4360 7.8 8.40 38.84 4.18 .19 5.9 35600 3790 40 2.7 18600 3200 1.7 Y 2S CR SOYQ036S 208 3 34000 4360 7.8 8.40 38.84 4.18 .19 5.9 35600 3790 40 2.7 17100 3200 1.6 Y . • 25 CR 50YQ036S 230 3 34000 4360 7.8 8.40 38.84 4.18 .19 5.9 35600 3790 40 2.7 17100 3200 1.6 Y 2S CR SOYQ04231 230 1 42500 56S0 7.5 8.30 47.33 5.30 .14 5.7 42500 IJ840 40 2.5 22200 39:!0 1.7 Y 25 CR SOYQ04S31 230 l 48S00 6450 -· 7.5 8.45 54.37 6.01 .13 6.1 51500 5470 40 2.7 27800 4500 1 •. 7 Y 25 CR SOYq0484 208 3 48500 64S0. 7.5 8.4S 54.37 6.01 .13 6.1 51500 5470 40 2.7 27800 4500 1 •. 7 Y 25 CR 50YQ0485 230 3 48500 6450 7.5 8.45 S4.37 6.01 .13 6.1 51500 5470 40 2.7 27800 4500 1.7 Y 25 CR SOYQ0486 460 3 48500 6450 7.5 8.45 54.37 6.01 .13 6.1 51500 5470 40 2.7 27800 4S00 1.7 Y 25 CR 50YQ12430 230 1 24000 2697 8.9 9.00 26.00 2.52 .25 6.3 24400 2655 40 2.6 12600 1938 1.9 Y 25 CR 50YQ13030 230 1 29200 3561. 8.2 8.60 32.10 3.34 .19 6.3 28400 3073 40 2.6 16200 2492 1.9 Y 25 CR 50Yql3630 230 1 34400 4247 8.1 e.so 37.oo 3.94 . .19 6.1 35600 3828 40 2.7 18500 2850 1.9 Y 25 CR 50YQ14230 230 1 42000 5455 1.7 8.50 45.50 s.oo .14 6.1 44500 ~760 40 2.7 24200 2846 1.9 Y 25 CR 50YQ14830 • 230 1 49500 6266 7.9 8.50 55.40 6.09 .14 5.9 53000 5650 40 2.7 28800 4431 1.9 Y 25 DN 542EE,FE090 460 3 86000 10238 8.4 87000 8792 80 2.8 50000 7327 2.0 Y 25 ON 542EE120 460 3 119000 14600 8.2 119000 12300 80 2.8 64000 9200 2.0 Y 25 DM 542EE120000 460 3 120000 14700 8.2 120000 12200 80 2.8 65000 9200 2.1 Y 25 DN 542EE120016 460 3 120000 14700 8.2 120000 12200 80 2.8 6S000 9200 2.1 Y 25 DH S42EE120030 460 3 120000 14700 e.2 120000 12200 80 2.8 65000 9200 2.1 Y 25 DH 542EP,FP090 208 3 86000 10238 8.4 87000 8792 80 2.8 S0000 7327 2.0 Y 25 DN 542EP,FP090 230 3 86000 10238 8.4 87000 8792 80 2.8 50000 7327 2.0 Y 25 DN 542EP120 208 3 119000 14600 8.2 119000 12300 80 2.8 64000 9200·2.o Y 25 DN S42EP120 230 3 119000 14600 8.2 119000 12300 80 2.8 64000 9200 2.0 Y 25 DH 542EP120000 208 3 120000 , 14700 8.2 120000 12200 80 2.8 65000 9200 2.1 Y 25 DM 542EP120000 230 3 120000 14700 8.2 120000 12200 80 2.8 6S000 9200 2.1 Y 2S DN 542EP120017 208 3 120000 14700 8.2 120000 12200 80 2.8 65000 9200 2.1 Y 25 Dtt 542EP120017 230 3 120000 14700 8.2 120000 12200 80 2.8 6S000 9200 2.1 Y 25 DH 542EP120031 208 3 120000 14700 8.2 120000 12200 80 2.8 65000 9200 2.1 Y 25 ON 542EP120031 230 3 120000 14700 8.2 120000 12200 80 2.8 6S000 9200 2.1 Y MANUFACTURER: CARRIER PAGE 84 ' CtlCUFR (COHFRESSOR/NON-CottPRESSOR Cot!BINATION USED FOR RATING) -FOR SPLIT SYSTEM ONLY:- l: COMFRESSOR TESTED WITH NON-COHPP.ESSOR UNIT AS tlOST LIKELY TO REPRESENT HIGHEST SALES VOLUHE ON A NATIONAL BASIS. 2 = ANY OTHER COMPRESSOR/NON-COMPRESSOR CONBINATIOH. l DESCRIPTION OF CODES:-· · CR = CARRIER ~DESCRIPTiott OF TYPES:-DH = DAY AND NIGHT 2S = SINGLE PACKAGE HEAT PUNP~ AIR SOURCE ,