HomeMy WebLinkAbout2236 RUTHERFORD RD; 103; CB960796; PermitBU IL DING PERMIT .. Permit· No: CB960796
.. 07/17/96 16.:01
Page· 1. of 1
Job Addre:ss: 22.36 RUTHERFORD RD
Permit Type: INDUSTRIAL TENANT IMPROVEMENT
Suite:
_Project No: A.9601105 '
1 Development No : . ·-I
119· I
Parcel No; 212-061~26-00 Lot#: 8596 07/1.7/% ·00~1 i\~ ·1 .,_ V.~ -02
Valuation: 197,210 . ·construction T~~'1'ttff VN .210AOuoO
Status: ISSUE'~ . _Occupancy Groupr B/F-1 Reference#~
'Description: 7585 SF l'I,-SUDIOS ,ELE-C,RESTRMS Applie'd: 05/02/96
Apr/Issu,e: ·07/17/96
Entered By : · RMA :
619,-452.--:3188
. ~ SHOWER,6 A/C UNITS-ROOF,STUDIO ARTS
App1/Ownr KLOHA,LARRY
5355 MIRA SORRENTO PL
SAN D!EGO CA 92121 ,,.-,-,-..,.~,..--.......__,...,...., .
.,·_ x** Fees Required *** ,.,,,.-/ H*/--.;) !'iFe~G~lected & Credits· ·*** -/ ~ rf '., ~ ·
~----.--Fees:------21, 704~~\? -\'.St,;11 c5y-, -'." ~----------------------
Adjustments: // . oo() 1 _,. To'{\afil¼·rdf ~: ._. . . 00 . .
Total Fees : 21/7 O,~ . O o<::::.J/~-Tote,1.~~~~~~ · 6 2 4. 0 0 . .
. I ;·i \"-/ P;~1 f'Ealct ~; ~: \ . 21, OBO. 00
__ .Fee_ des~ription _J is;;;'/'-___ _:~~~its _ ~~~ · _. _:xt _fee __ Da:a
Building Permit ( C::::::::, / ' ... ------..... .?' (/' . 983. oo
;!:~n~h~~~ion Fee I ~l { ·--.. . ... ...-~,;.! t§) · 6!i:gg
Enter Number of EDU· z -W;3-t.er ~~ r;: ~ . 6480. 00
Enter "Y" to Auioc\:tlc Li•;,~'s-~fai~i > \_{t . · 3589. 00 Y
. . (Lie 'T'\:x) C.F.~),_' ~":' p· j . I 3313.00
· ( 'l'JS.F ~a'} ~ · / 20:16. 00
; _ \( 1'IF CF~ F&1d) . .-_ , . -18.60. 00
Enter Bridge Fee \ {(~ ~ INC0~~~~15'08. ir6 <'~-:::-:, / 250-8. 00
* BUILDING TOTAL \ 1,.:::, /~f ~.__Jl__..--7~---,v.\5·/ 21429. 0-0-
: Enter "Y" for Plumbing~s$ttlf/?~e ) r r-\\J 20.00·Y
.. Ea9h Plumbing Fixture or"---'t_rai;{~ ij /i:2 ro\'\~\\ / 7. 00 42. 00
'. "Each Install/Repair Water hl~E' U7 ~) .)') ~.., · 7. 00 '7. 00
Each ~a~er Heater and/or Vent~.:.__~-·~__.....-....-/1 7. 00 7. 00
.Gas Piping System > · · 1 7.00 7.00
*··PLUMBING TOTAL :$3. 00
Enter "Y" for Electric Issue Fee > 1~.00 Y
.. Remodel/Alter Per AMP > 400 . 25 100. oo
* ELE9TRICAL TOTAL 110.QO
Enter 'Y 1 for Mechanical Issue Fee> ·15,00 Y
Install Furn/Ducts/Heat Pumps . > 6 9. oo_· 54. 00
Eaci Exhaust Fan · · > · 2 6.50 13.00
* MECHANICAL TOTAL 82.00 ·
l . . . FJNM. APPROVAL I
_ _. . INSP.· ~ .DATE JJ/;3lrt.
. . · /CLEARANCE -
CITY OF CARLSBA~-:-;:~::-:;;:-' -----;.._~~...,.J
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1.161
I (!l,D:, 0 0 0 0 I'/
PLAN CHECK NO. q b 0 PERMIT APPUCA'ITON
City of Carlsbad Building Department
FSf. VAL 7. d>:f Q 2075 Las Palmas Dr •• carlsbad, CA 92009 (619) 438-1161
1. PERMIT 'l'YPE J: :r:::c.. Pl.AN CK DEPOSIT , G xq-
vAIID. BY ___ """" ______ __:. __
~ ....... ~ From li~t 1 (see back) .give code of Permit-Type: ---~=-·----1_._J::::.__ ________ _
DATE ________________ _
For. Residential Projects Only: From list 2 (see back) give
Code of Structure-Type:--------------------
Net Loss/Gain of Dwelling Units __________________ _ 734.9 05/02/96 0001 01 02
2. PRQJECT INFORMATION FOR OFFid;-rrsifbNLY 624~00
Address ~;2. 3&, (Zurn~~~ ~,.o • Bu1ldmg or suite No. l \ 7 / I \9
Nearest Cross Street VLT / 111. &()(A-
a 2 Soils Repo_rt D 1 Addressed Envelope
DESCRIPTION OF W~ 0 FFtc£ / f',12.o~\aN ~ANT I MW:,r2-oveteJt-_. r 111 .,,:h-;
-, L::"e, c~-P._1Jof M-PUA,TC.[) G '!J]-L -rs; 1!:lAf ff'AP ltt...J' r I I'IIPw't,K+-J-T v. SQ. Fr. :;;;, o;., # OF STO ES "'-#, OF BEDROOMS # OF BATHROOMS
3_. WN IACI PERSON (If different from applicant)
NAME (last.name first) ADDRESS
CITY · STATE ZIP CODE DAY TELEPHONE
s. ~~;zt~:::rst) E~S~ ~"N M~M,~~wr ADDRESS '314-2.. v,s,~ WA'-( -=#-2.o'2...
P CODE 't2b$'"~ 0AY TELEPHONE ({p {'1 121 '~ 7 l::,4-
CITY "Ef\:J,1-fo~ .L STATE e,:s;--
/1 ,4,,.n (1t€Pf€,l( / ,t: C'J{.
ADDRESS
ZIPCODE ~ C/U7'f LICENSE. CIASS
DAY TELEPHONE ( G:z.t:9) ~~
714 -'ft/'Z-LF!><e, ( -::Xltf-C STATE LIC. # 1 CITY BUSINESS LIC. #
ast name 1rst '5AMe:.
CITY STATE ZIP CODE DAY TELEPHONE STATE IJC. #
1. WORKERS' CDMPENSA'nbN
D
0
0
Workers' Compensaoon Declaration: I hereby affirm that I have a ceruhcate of consent to selhmsure issued by the Director of lndustnal
Relations, or a certifica ofWor 'Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of surer eof filed with the Building Inspection Department (Section 3800, Lab. C).
EXPIRATION DATE /-I -f
w r-U1 er c ara on: ere y a 1rm am .exempt rom e o owmg reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intend'ed'
or offered for sale. If, however, the building Oli improvement is sold within one year of completion, the owner-builder will.have the burden
of proving that he did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed-contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's license Law).
I am exempt under Section _______ Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
ciny structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's license Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation ofSection 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500)).
SIGNATIJRE DATE
COMPLETE 11-its SECTION FOR NON-RESIDEN11AL BOlt.blNG PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 2~5, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? .a YES ~NO
Is the applicant or future building oc~ant required to obtain a permit from the air pollution control district or air quality management district?
DYES ~NO
Is the facility to be constructed within.J.?90 feet of the outer boundary of a school site? a YES ~o
IF ANY OF.TIIE ANSWERS ARE YFS, A FINAL CERTIFICATE OF CXX:lJPANCY MAY NOT BE~ AFTER JULY I, 1989 UNLFSS TIIE APPUCANT
~ MET OR IS MEETING TIIE REQUIREMENTS OF 1llE OFFICE OF EMERGENCY SERVICES AND 1llE Aill POU.UTION OON1ROL DISllUCT.
9. OONSIROCIIDN LENDING AGENCY .
I hereby afhrm that there JS a construction (endmg agency for the performance of the·work for which this permit 1s issued (Sec 3097(1) ClVII Code).
LENDER'S NAME LENDER'S ADDRESS
lo. APPllCAN1' CHkuFlc.XliON
· I certJfy that I have read the apphcaoon and state that the above mformatlon 1~ correct. I agree to comply with all City ordmancei; and State laws
relating to building construction. I hereby authorize representatives of the qty.of Carlsbad.to enter upon the above mentioned property for inspection
purposes. I AISO AGREE 10 SAVE INDEMNIFY AND KEEP HARMLFSS TIIE Cl1YOF CARISBAD AGAINST All. ~ILITIF.S, JUDGMENTS, OOSTS
AND EXPENSES WIIlCH MAY IN ANY WAY Acx::RUE AGAINST SAID CITY IN OONSEQUENCE OF TIIE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permi.t issued by the Building Official under the provisions.of this Code shall expire by limitation and become null and void if the
building or work authorized. by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or aba oned at any time a ter the work "is commenced for a period of 180 days (Section 303(d) Uniform Buildi,q1).
APPLICANTS SIGNATURE _ . DATE: ~ ~
ile YE.ll.OW: Applicant PINK: Finance
, t), _ ioot"-7 l..))-1t-u '
', '
-07/17/96 16:02
Page , 1 of 1
S E W E R P E 8 M I T
Job .. Address: .2236 RUTHERFORD RD
Permit Type: SEWER -OFFICE/WAREHOUSE
Parcel .No: 212-061-26-00
,·Permit N-o: SE960052
Bldg: PlanCk#~ CB960'196
Suite: 119 ~
8596 07/17/96,~00i Qi
De$cription: 7585 SF TI,CREATE STUDIOS,ELEC·
, : RESTROOMS, SHOWER, 6 A.C UNITS/ROOF
-Pe.rmi tee : KLOHA, LARRY
5355 MIRA SORRENTO PL
SAN DIEGO CA 92121
619-4s2-31irn
... 02
stih-fli1wr rss~R., ,~
Applied: ~5/f6Y7950
Apr/Issue: 07/17/96
Expired:
Prepared ::Sy:·. MAM
f INAL APPROVAL
lNSP; . DATE ___ ,
CLEARANCE------
. '
CITY OF 'CARL$BAD .
2075 Las Palmas-Dr., Carlsbad, CA 92009 (619) 438-1161
,.,
CITY OF CARL_SBAD
INSPECTION REQUEST
PERMIT# CB960796 FOR 11/13/96 INSPECTOR AREA TP
PLANCK# CB960796
OCC GRP B/F-1
CONSTR. TYPE VN
DESCRIPTION: 7585 SF TI,SUDIOS,ELEC,RESTRMS
SHOWER,6 A/C UNITS-ROOF,STUDIO ARTS
TYPE: ITI
JOB ADDRESS: 2236 RUTHERFORD RD
APPLICANT: KLOHA,LARRY
CONTRACTOR:
OWNER:
REMARKS: MW/KEVIN/492-1881
SPECIAL INSTRUCT:
STE: 119 LOT:
PHONE: 619-452;:;_-3188
PHONE:
PHONE:
INSPECTOR _...,,, '--'--'----------------------
TOTAL TIME:
-~RELATED PERMITS--PERMIT#
SE960052
AS960053
FAD96028
CB961909
TYPE swow
ASC
FADD
SIGN
STATUS
ISSUED
ISSUED·
ISSUED
ISSUEP
CD LVL DESCRIPTION
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final .Mechanical
ACT COMMENTS
1)/J -----'------------t-~--------
------------------------------------· ---------------------------
-----------------------------------· ---------------------· ---_.___ _________________ _
***** INSPECTION H!STORY *****
D~TE
110796
100796
100396,
091996
091396
091296
091296
091296
091296
091196
091196
091096
0910-96
091096
091096
090996
090996
090996
09049,6
090396
090396
0903·96
083096
DESCRIPTION
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Fraine/Steel/Bolting/Welding
Rough/Ducts/Dampers
Rough Electric
T-24 H-Cap Consultation
Rough Electric
T-24 a-cap consultation
Frame/Steel/Bolting/Welding
Frame/Steel/Bolting/Welding
Rough Electric
Rough/Ducts/Dampers
Frame/Steel/Bolting/Welding
Rough Electric
Rough/Ducts/Dampers
Rough/Ducts/Dampers
Frame/Steel/Bolting/Welding
Rough Electric
Rough/Ducts/Dampers
Frame/Steel/Bolting/Welding
ACT INSP
NS TP
CO TP
CO TP
CO PY
CO TP
AP TP
CO TP
AP TP
PI TP
NR TP
PI TP
AP· TP
AP TP
AP TP
AP TP
CO TP
CO TP
CO TP
NR Ti?
NR TP
NR TP
NR TP
CO TP
COMMENTS
SEE NOTICE
PLANS/JOB CARD
JOB NOT COMP
F.C. & TAPE CORR-TOP
EQPT@ ROOF
MAIN & SUB PNLS
PI NOT COMP
T-BAR GRID
T-BAR GRID
CEIL LITES
CEIL UNITS,DUCTS
NLNG B.N.
GRID LITE SUPPORT,HVAC DISC
SEISMIC GRL & SECONDARY COND
REV -PLNS NOT ON SITE
REV PLANS NOT COMPLETE
REV PLANS NOT COMPLETE
REV PLANS NOT COMPLETE
SEE ATTCH
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB960796 FOR 11/13/96
DESCRIPTION: 7585 SF TI,SUDIOS,ELEC,RESTRMS
SHOWER,6 A/C UNITS-ROOF,STUDIO ARTS
TYPE: ITI
JOB ADORES$: 2236 RUTHERFORD RD
INSPECTOR AREA TP
PLANCK# CB960796
OCC GRP B/F-1
CONSTR. TYPE VN
STE: 119 LOT:
***** INSPECTION HISTORY*****
DATE
082796
082396
08,2396
082396
0823~6
082396
082396
082296
082196
082096
082096
081996
081696
081596
080896
080896
080896
080596
072396
072296
071996
DESCRIPTION
Const. Service/Agricultural
Frame/Steel/Bolting/Welding
Frame/Steel/Bolting/Welding
Rough Electric
Rough/Ducts/Dampers
Frame/Steel/Bolting/Welding
Insulation
Frame/Steel/Bolting/Welding
Frame/Steel/Bolting/Welding
Rough/Topout
Frame/Steel/Bolting/Welding
Rough/Topout
Interior Lath/Drywall
Interior Lath/Drywall
Frame/Steel/Bolting/Welding
Rough/Topout
Rough Electric
Frame/Steel/Bolting/Welding
Ftg/Foundation/Piers
Ftg/Foundation/Piers
Underground/Under Floor
ACT INSP
Pt TP
AP TP
AP TP
AP TP
AP TP
AP TP
AP TP
CA TP
CA TP
AP TP
PI TP
CO TP
NR TP
AP TP
AP TP
AP TP
AP TP
CO TP
AP TP
CO TP
AP TP
COMMENTS
LOCATION FOR NEW PNL CK
1 HR TUNNEL HIGH WALLS
CEIL.CNTR RM,RESTRM,& OFFICES
CEIL.CNTR RM,RESTRM,& OFFICES
CEIL.CNTR RM,RESTRM,& OFFICES
WALLS@ MAI~ STRWELL
HIGH W~LLS@ W.H.
HIGH WALL REV & TUNNEL
FAILED WATER TEST
NOT COMPLETE
LOW WALLS 1 & 2 FLR
1ST & 2ND FLR LOW WALLS
ND REV WALL TO TRUSS DETAIL
FTN DTL 1/A6 * SLAB PREP
NOT READY
WATER TEST, ND U/B A/B ·
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING ~ PLANNING U/M WATER
PLAN CHECK#: CB960796
PERMIT#: CB960796
PROJECT NA1{E: 7585 SF TI,SUDIOS,ELEC,RESTRMS
SHOWER,6 A/C UNITS-ROOF,STUOIO ARTS
ADDRESS: ffi.26-RUTHERFORD .RIL S1[IX...i{#=~ll9~J
CONTACT PERSON/PHONE#: MW/KEVIN
SEWER DIST: CA WATER DIST: CA
INSPECTED ~
BY: · Q-.~'u~ DATE /
INS·PECTED: ? t?(>l APPROVED
INSPECTED
BY:
INSPECTED
BY:
COMMENTS:
DATE
INSPECTED:
DATE
INSPECTED:
APPROVED
APPROVED
DATE: 09/13/96
PERMIT TYPE: ITI
ij~~[E~~~~
~ SEP 1 7 1996 ~
By
DISAPPROVED
DISAPPROVED
SEP-12-1996 11:31 NEW WESJ ELECTRIC
45a CALLE MIGUEL • .I ~i ~l W2.
September 12, 1996
BUILDING DEPARTMENT
Mr. Tim Phillips
CITY OF CARLS:BAD
2075 Los Pabnas Drive
Carlsbad, California 92009
.l;LEOTRIC
(714)492-192-4
FAX .492-7447
RE: S.TJ1IUQ ARTS
h236 Rutherf"or~-RQlid, #:!17:~112]
Carlsbad, CA
714 492 7447
SAN CLEMENTE, CA 92672
Sent via fax 619-43 8-0894
Phone 619-438-3550
REQUEST FOR METER INSTALLATION
Dear Mr. Phillips
Please accept this letter as notification that we are complete with the main electrical service the
feeder wires and the panel termination's. If at all possible we would like to have the meter
installed on 'Friday 9-13-96. This meter is for testing purposes only.
If you have any questions with regard to this letter, please contact me at your earliest
convenience.
Sincerely,
NEW WEST ELECTRIC
--Paul Haveruk
P.01
TOTAL P.01
SEP-05-96 04:38 PM 4363725.2M87A86P
Sept(!mbcr 5, 199~
Mr. 'f'im Phillip,
C;ty Of C1rl1bad
2075 Lat Palmas Drive
Carlsbad, CA ~2009
oMcPARLANE
<;<ASSQCjATES
Re; Studio Arts Multlmtdia As· Duflt$ . t'zz 7/ :Z'vr.Ql':.i,d!.iJJJ Our FIie #1614 tf-.1, :>Jl!..&4-4!7~-_
Ota, Tim,
714 492 3102
I'm writing in regards to 1he HVAC As-Built drawings 9~norated by the meehanipa!
eonttac10r.
I hsve been infom,ect that the owner and mechanical <:oritractor have agreefJ to vah.1e
engtnottin~ modifications. These changes affec::t the thermal.zoning and noise criteria for
the main studio, but do not .ippe;r to violato any port:Jlnmenr codes or Life Safety issues.
If you have any other question, regarding the I IVAC As .. Builts, please don't hesitate to c-11.
Thank you, ·
~#fr.A.___,
Paul F. McParlane, P.E.
McF'arlant & Assoelates, Inc.
PFM: smt
f.lll\~llf'lltl'\'411o.,,/l,r,,
It 111-, M ,. : P ,'\ i ~ 1 P' A~~ ~-'11 d' A It L II "'I I 1' t .i n ~ J r.; 11 ~. , I. ,'.I 1· r.: [ (
96*4, !,,11~1111 !,!·II;, r,,h,,:, ~11i•• ~,.~ ~~n O,ti;u. C,.l,flJl'l'lw ,;2in f'h 1.t.1· ;1~,,.,r,i-~,.;,: :~19) t~ ,,!l:·t>C•DAT..-. ;til9• J1;t.~lf.&
P.02
DATE: 7/8/96
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-796
EsGil Corporation
Professiona{ Pfan ~view 'Engineers
SET: III Supp.
PROJECT ADDRESS: 2236 Rutherford Road
PROJECT NAME: Studio Arts Multimedia Suite 117-119
Cl APPLICANT ~ CIFIRE
CJ PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
• The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are b~ing held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been faxed to:
Larry Kloha; Smith Consulting Architects
Fax#: 452-3907
• Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: ) Telephone #:
• REMARKS: City to review: .
21. City to field verify the existing parapets will screen the new roof equipment.
The designer inked additional information on sheet A6 and on M2.
By: Pete Fischer
Esgil Corporation
0 GA 0 CM O GP O PC
· Enclosures:
log 7/8/96 trnsmtl.dot
DATE: 7/2/96
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-796
EsGil Corporation
Professiona{ Plan ~view 'Engineers
SET: III
PROJECT ADDRESS: 2236 Rutherford Road
PROJECT NAME: Studio Arts Multimedia Suite 117-119
D APPLICANT ~ DFIRE
D PLAN REVIEWER
D FILE
_· D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's ********** codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the _enclosed check list
and should be corrected and resubmitted for a complete recheck.
• The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
• The applicant's copy of the check list has been faxed to:
Larry Kloha, Smith Consulting Architects
Fax#: 452-3907
• Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
' Date contacted: (by: ) Telephone #:
D REMARKS:
By: Pete Fischer Enclosures:
Esgil Corporation
igJ GA igi CM D GP D PC 6/28/96 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576
Carlsbad 96-796
7/2/96
RECHECK PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2236 ;Rutherford Road
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 6/28/96
REVIEWED BY: Pete Fischer
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 96.;796
SET: III
DATE RECHECK COMPLETED:
7/2/96
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced_ by the Building Department. You may have other corrections
based on laws and ordinances enforced qy the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans Will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A. Please make all corrections on the original tracings and submit two new sets of prints to:
Esgil Corporation or the jurisdiction's building department.
B. -To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C. The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. Please contact me if you have any
·questions regarding these items.
D. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. -Have changes been made not. resulting from this list?
DYes DNo
Carlsbad 96-796
7/2/96
18. Indicate that the new roof mechanical equipment platforms will only load the
existing trusses at the truss panel points.
21. City to field verify the existing parapets will screen the new roof equipment.
The designer inked additional information in detail 3/A6 and on M2.
If you have any questions regarding these items, please cont~ct Pete Fischer of Esgil
Corporation at (619) 560-1468. Thank you.
+ ELECTRICAL PLAN REVIEW
+ PLAN REVIEWER: Eric Jensen
1. Note on page E-5 that service bus taps will be certified by an independent
testing laboratory (NRTL). An alternate to this requirement would be to provide
the manufacturer's installation instructions for that particular switchgear and have
the gear available (de-energized) for compliance inspection.
2. Show location of "Service Disconnecting Means" identification: Service
Disconnect 1 of 4, Service Disconnect 2 of 4, Service Disconnect 3 of 4, Service
Disconnect 4 of 4. Placards will be required if any disconnect is located remote
from other disconnects.
Note: If you have any questions regarding this electrical plan review list please
contact Eric Jensen at (619) 560-1468.
+ PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
+ PLAN REVIEWER: Glen Adamek
• ENERGY CONSERVATION
47. On the plans show the wattages of the light fixtures as per the energy design,
L TG-2 form. Also the signed L TG-1 form must be imprinted on the plans
50. Clearly show the daylit ~reas on the plans and correct the lighting controls to
provide the required daylit area lighting controls, for lighting in daylit areas. Title
24, Part 6, Section 131 ( c). Correct th.e lighting controls for room numbers 103
and 201.
Note: If you have any questions regarding this plan review list please contact
Glen Adamek at (619) 560-1468. To speed the review process, note on this list
(or a copy) where the corrected items have been addressed on the plans.
EsGil Co_rporatlon
Profession(f{ PCan !F.f_view 'Engineers
DATE: 6/21/96
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-796
D~~NT Ca JUR§ D FIRE
SET: II
PROJECT ADDRESS: 2236 Rutherford Road
PROJECT NAME: Studio Arts Multimedia Suite 117-119
a. PLAN REVIEWER
a FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's ********** codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies .identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
• The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
• The applicant's copy of the check list has been faxed to:
Larry Kloha,-Smith Consulting Architects
Fax#:_ 452-3_9Q7
• Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant thc;lt the plan check has been completed.
Person contacted:
Date contactt;!d: &jJ{ii, (by:fi,r) ~ Telephone #:
D RE:MARKS:
By: Pete Fischer Enclosures:
_ Esgil Corporation
[2] GA [2] CM D GP D PC 6/13/96 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576
·. ·· ... · ..
Carlsbad 96-796
6/21/96
RECHECK PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2236 Rutherford Road
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 6/13/96
REVIEWED BY: Pete Fischer
FOREWORD (PLEASE READ):
PLAN_ CHECK NO.: 96-796
SET: II
DATE RECHECK COMPLETED:
6/21/96
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. Thi.s plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A. Please make all corrections on the original tracings and submit two new sets of prints to:
Esgil Corporation or the jurisdiction's building department.
B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
.revised plans.
C. The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. Please contact me if you have any
questions regarding these items.
D. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
DYes DNo
Carlsbad 96-796
6/21/96
9. Recheck all first floor exiting.
a. The left exit for the second floor may only exit through one adjoining room
at the first floor per 1003.5.. Show lobby 101 is constructed as
required for a 1 hour corridor, including the d·oors, fire/smoke
dampers, 1 hour walls, 1 hour ceilings, etc.
b. Two exits are required for the first floor occupants. Recheck the exiting
through adjoining rooms and exiting through storage per 1003.5. The
first floor occupants must have access to two exits.
c. Corridors must provioe continuous protection to the exterior of the
building. Interruptions by an intervening room is not permitted. Section
1005.1. .
d. When two exits are required, dead end corridors and exit balconies are
limited to 20 feet. Section 1005.5.
e. Corridors serving 30 or more occupants shall have walls and ceilings of
one-hour construction. Show compliance or clearly show on plans which
exception has been satisfied.
13, 14, 15 & 16. See the original comments for the first floor 1 hour corridors ( corridor
118 is "OK" as shown).
17. Combination smoke and fire dampers shall be installed at all ducted or unducted
air openings at penetrations of fire resistive corridors. Secs. 713.1 O and 713.11.
18. Provide plans and calculations to show all new roo'f mounted equipment are
adequately supported.
21. City to field verify the existing. parapets will screen the new roof equipment.
24. Revisions: Show 1 hour walls and ceiling below the new storage under stair 109.
If you have any questions regarding these items, please contact Pete Fischer of Esgil
Corporation at (619) 560-1468. Thank you.
+ ELECTRICAL PLAN REVIEW
+ PLAN REVIEWER: Etic Jensen
This recheck is based on information submitted after the initial plan check.
All items on the initial electrical plan check were satisfactory. However,
several new items developed at the resubmittal.
1. Note on page E-5 that service bus taps will be certified by an independent
testing laboratory (NRTL). An alternate to this requirement would be to provide
the manufacturer's installation instructions for that particular switchgear and have
· the gear available (de-energized) for compliance inspection.
Carlsbad 96-796
6/2·1/96
2. $how location of "Service Disconnecting Means" identification: Service
Disconnect 1 of 4, Service Disconnect 2 of 4, Service Disconnect 3 of 4, Service
Disconnect 4 of 4. Placards wilf be reqLJired if any disconnect is located remote
from other disconnects.
Note: If you have any questions regarding this electrical plan review list please
contact Eric Jensen at (619) 560-1468.' To speed the review process, note on
this list (or a copy) where the corrected items have been addressed on the plans.
+ PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
+ PLAN REVIEWER: Glen Adamek
• MECHANICAL (1'994 UNiFORM MECHANICAL CODE)
41. Show the location of the required access ladder to roof mounted HVAC
equipment. UMC, Section 321.8
44. Detail overflow (secondary) condensate. discharge from air conditioning units that
are in a ceiling space to readily ob$erved locations. UMC Section 310.1.1
45. The required fire rat~d corridors are not to be used to convey air to or from
rooms. UMC Section 601.1.1
• ENERGY CONSERVATION
46. On the plans clearly show the wall and roof insulation locations, thickness, and
R-values, as per the energy design.
47. On the plans show the wattages of the light fixtures as per the energy design,
LTG-2 form.
48. Provide ~utomatic shut-off controls for lighting as per Title 24, Part 6, Section
131(d).
49. Show bi-level lighting controls as per Title 24, Part 6, Section 131 (-b).
50. Clearly show the daylit areas on the plans and correct the lighting controls to
provide the required daylit area lighting controls, for lighting in daylit areas. Title
24, Part 6, Section 131 (c).
Note: If you have any questions regarding this plan review list please contact
Glen Adamek at (619) 560-1468. To speed the review process, note on this list
(or a copy) where the corrected items have be~n addressed on the plans.
CJ1 I ~ 0
--'
z 0
---. :r. -. ":
--~ -
r
L
---
15'-0" or nearest 60"
high opaque partition
..
...,. J __ ..._
--. ---r""'
= -. =--
·..-:: -
--:; =-:;;·
,_
:=:· --,.._
.... ::::· -2
-: -~ ·::
'--. -·~ -,.._ --
DATE: 5/14/96
JURISDICTION: Carlsbad
PLAN CHECK NO.: 96-796
EsGil Corporation
Professiona{ Pfan !fteview '.Engineers
SET:I
PROJECT ADDRESS: 2236 Rutherford Road
PROJECT NAME: Studio Arts Multimed,ia Suite 117-119
0 APPLICANT
~URi[) a FIRE
0 PLAN REVIEWER
0 FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's ********** codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
• The check list transmitted herewith is for your information. The plans are being held.at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
• The applicant's copy of the check list has been sent to:
Larry Kloha, Smith Consulting Architects
5355 Mira Sorrento Place, Suite 750, San Diego, CA 92121
• Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant-that the plan check has been completed.
Person contacted:
Date contacted:
D REMARKS:
By: Pete Fischer
Esgil Corporation
(by:
~ GA ~ CM D GP D PC
) . Telephone #:
Enclosures:
5/6/96 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576
Carlsbad 96..-796
5/14/96
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 96-796
OCCUPANCY: B,Fl
rYPE OF CONSTRUCTION: VN SPR
ALLOWABLE FLOOR AREA: NO CHANGE
JURISDICTION: Carlsbad
USE: Office/Production Studio
ACTUAL AREA: TI = 7585
STORIES: 2
HEIGHT: NO CHANGE
SPRINKLERS?: YES
REMARKS:
OCCUPANT LOAD: UNDER REVIEW
. DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 5/ 14/96
FOREWORD (PLEASE READ):
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 5/6/96
PLAN REVIEWER: Pete Fischer
This plan review is limited to the technical. requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1994 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot
I
Carlsbad 96-796
5/14/96
1. Please make all corrections on the original tracings and submit two new sets of
prints, to:
2.
3.
4.
5.
6.
7.
8.
9.
Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123,
(619) 560-1468.
OR
The jurisdiction's building department.
Provide a note on the site plan indicating the previous use of the tenant space or
building being remodeled. Section 106.3.3. -
Indicate the use of all spaces adjacent to the area being remodeled or improved.
Show any existing fire rated area separation walls, occupancy separation walls,
demising walls, shafts or rated corridors.
The new 1 hour walls reference detail. 3/A3 which is only partial height. Provide
a 1 hour ceiling at the new 1 hour stair.
Identify if any existing walls to be removed are bearing walls and/or shear walls.
Provide structural calculations and details for all modified structural walls.
Clarify the use and operations in the production room. Clarify the maximum
number of occupants within the main production room. Will there be any
hazardous materials within the production room?
The width of the required level area on the side into which doors swing shall
extend 18 inches past the strike edge for interior doors. Dimension the
clearance at doors 102, 103, 106, 108 and 112. Section 2-3304, Title 24.
~echeck all first floor exiting.
a) The left exit for the second floor may only exit through one adjoining room
at the first floor per 1003.5.
b) Two exits are required for the first floor occupants. Recheck the exiting
through adjoining rooms and exiting through storage per 1003.5.
c) Corridors must provide continuous protection to the exterior of the
building. Interruptions by an intervening room is not permitted. Section
1005.1.
d) When two exits are required, dead end corridors and exit balconies are
limited to 20 feet. Section 1005.5.
e) Corridors serving 30 or more occupants shall have walls and ceilings of
one-hour construction. Show compliance or clearly show on plans which
exception has been satisfied.
Carlsbad 96-796
5/14/96
10. Section 1005.7, Exceptions 5, 7 and 8 do not apply to common corridors where
the corridor serves as an exit for non-office areas (manufacturing, warehouse,
etc.).
11. Exit doors should swing in the direction of exit travel when serving any
hazardous area or when the area served has an occupant load of 50 or more.
Section 1004.2. ·
12. Recheck all exit sign locations to at the first floor per comment 9. Section 1013.1.
13. One-hour fire-rated corridors shall have interior door openings protected by tight-
fitting smoke and draft control assemblies rated 20 minutes, except openings in
interior walls of exterior exit balconies. Doors shall be maintained self-closing or
be.automatic closing by action of a smoke detector per Section 713.2. Doors
shall be gasketed to provide a smoke and draft seal where the door meets the
stop on sides and top. Section 1005.8.1.
14. Total area of all openings, except doors, in any portion of an interior corridor,
shall not exceed 25 percent of the area of the corridor wall of the room which it is
separating from the corridor. Such openings shall be protected by fixed glazing
listed and labeled for a fire-protection rating of at least 3/4-hour. Section 713.9.
15. Provide a complete architectural section of the all 1 hour corridors showing all
fire-resistive materials and details of construction for all floors, walls, ceiling and
all penetrations. Section 1005.7.
16. If a room with an exhaust fan has a door opening into a rated corridor, show how
makeup air will be provided to the room. The door cannot be undercut, nor can a
louver in the door be provided. Section 1005.8.1.
17. Combination smoke and fire dampers shall be installed at all ducted or unducted
air openings at penetrations of fire resistive corridors. Sections 713.1 O and
713.11.
18. Indicate the weight of all new roof mounted equipment, and provide plans and
calculations to show they are adequately supported.
19. Key note 3 on sheet A4 indicates "new footing as required." Clarify where they
are required, and justify the locations where they are not required.
20. Provide notes and/qr details to show that the floor and wall finish in toilet rooms
are surfaced with a smooth hard non-absorbent material extending five inches up
the wall. Similar surfacing shall be provided on the walls from the floor to a height
of 4 feet around urinals and within water closet compartments. Section 807.
Car1sbad 96-796
5/14/96
• CITY OF CARLSBAD SUPPLEMENT
21. Roof mounted equipment must be screened and roof penetrations should be
minimized (City Policy 80-6). Provide structural detailing for the screening.
• MISCELLANEOUS
22. See the attached for all plumbing, mechanical, energy and electrical corrections.
23. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
24. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction
list? Please indicate: ·
Yes D No D
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
619/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Pete Fischer at
Esgil Corporation. Thank you.
+ ELECTRICAL PLAN REVIEW
+ PLAN REVIEWER: Chuck Mendenhall
25. Indicate main service load from existing and proposed new loads.
26. Specify the wiring method you intend to use for this project (i.e., EMT, Metal
Flex, NMC etc.).
27. Show the location of panel "A". NEC 110-16,240-24,300-21.
28. Submit complete panel schedule(s). Indicating the panel mains and bussing
sizes.
29. Provide GFI protected receptacle(s) on the roof. See note A on sheet E-2 of the
plans. NEC 210-8(b)2 & 210-63
·' I
·1
I !
Carlsbad 96-796
5/14/96
30. Provide multiple switch light controls so that the lighting can be reduced by one
half in a uniform pattern. The switches must be located within sight of the lights
which they control. CBC Title 24, Sec 131 a-b
31. Specify the exit signs as being self-luminous or having a second source of
power ( battery or generator). This is required when two exits are required per
the UBC. USC 1013.4 and NEC 700-16.
32. The 60 amp overcurrent protection for panel "A" & 100 amp for panel "B" are
undersized for the connected loads shown in the panel schedules.
33. The #6 feeders shown on the single line are undersized for the connected loads
in the panels. Upgrade panels ''A" &"B" to accommodate the loads proposed.
Note: If you have any questions regarding this electrical plan review list please
contact the plan reviewer listed above at (619) 560-1468. To speed the review
process, note on this list ( or a copy) where the corrected items have been
addressed on the plans.
+ PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
+ PLAN REVIEWER: Glen Adamek
• PLUMBING (1994 UNIFORM PLUMBING CODE)
34. Show that water heater is adequately braced to resist seismic forces. Provide
two straps. One strap at top 1 /3 of the tank and one strap at bottom 1 /3 of the
tank. UPC, Section 510.0
35. Show the water heater in room opening into the repair garage is 18 inches above
the floor. UPC Section 510.1
36. Detail required 30 x 30 inch access clearance to water heater in attic, and
required drain pan under water heater. UPC Sections 511.0 & 510.7
37. Show P & T valve on water heater and detail drain line route from P & T valve to
the exterior. UPC Section 608.5
38. Provide calculations to show compliance with UPC, Appendix C, (Minimum
Plumbing Facilities) for facilities where the public congregates, as required by H
& S Code, Section 3981.
I
..
Carlsbad 96-796
5/14/96
. 39. Showers and tub-shower combinations, control valves must be pressure
balance or thermostatic mixing valves. UPC Section 410.7
40. Detail shower drain 48 inches minimum from threshold at entry into the shower
stall for wheel chair access. UPC Section 410.3
• MECHANICAL (1994 UNIFORM MECHANICAL CODE)
41. Detail ladder access to roof mounted HVAC equipment. UMC, Section 321.8
42. Provide req1:1ired outside air ducting for mechanical ventilation for the split
system heat pumps. USC, Section 1202.2.1
43. Detail access and working clearances to HVAC equipment.
44. Detail overflow (secondary) condensate discharge from air conditioning units that
are in a ceiling space to readily observed locations. UMC Section 310.1.1
45. Fire rated corridors are not to be used to convey air to or from rooms. UMC
Section 601.1.1
• ENERGY CONSERVATION
46. On the plans clearly show the wall and roof insulation locations, thickness, and
R-values, as per the energy design.
47. On the plans show the wattages of the light fixtures as per the energy design.
48. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section
131(d).
49. Show bi-level lighting controls as per Title 24, Part 6, Section 131(b).
50. Show the daylit areas and required daylit area lighting controls for lighting in
daylit areas. Title 24, Part 6, Section 131(c).
Note: If you have any questions regarding this plan review list please contact
Glen Adamek at (619) 560-1468. To speed the review process, note on this list
(or a copy) where the corrected items have been addressed on the plans.
Carlsbad 96-796
5/14/96
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 96-796
PREPARED BY: Pete Fischer DATE: 5/14/96
BUILDING ADDRESS: 2236 Rutherford Road ·
BUILDING OCCUPANCY: B, Fl TYPE OF CONSTRUCTION: VN SPR
BUILDING PORTION BUILDING AREA VALUATION VALUE
. ·(ft. 2) MULTIPLIER ($) .
Tl VALUE PER CITY APPLICATION 197,210
· Air Conditioning
Fire Sprinklers
10TALVALUE 197,210
~ 1991 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ 982.50
-~ 1991 UBC Plan Check Fee D Plan Check Fee by ordinance: $ 638.63
Type of Review: ~ Complete Review D Structural Only D Hourly
D Repetitive Fee Applicable D Other:
Esgil Plan Review Fee: $ 510.90
Comments:
Fire Services Review: D Complete Review
D Other:
D Suppression System
D FireAlarm
Esgil Fire Services Review Fee: $
Comments:
Sheet 1 of 1
macvalue.doc 5196
·1
City of Carlsbad
M #i h• 1 i 0441 i h· i •l4•kh;, ,t§ ,, I
ID
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
and/or specifications provided in your submittal;
therefore any changes to these items after this date,
including field modifications, must be reviewed by this
office to-insure continued conformance with applicc1ble
codes. Please review carefully all comments attached,
as failure to comply with instructions in this report can
result in suspension of permit to build.
D A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see the attached report of deficiencies marked
with D. Make necessary corrections to plans or
specifications for compliance with applicable codes and
standards. Submit corrected plans and/or specifications
to this office for review.
By: ____________ Date: ___ _
By: __________ Date: ___ _
By: __________ Date: ___ _
ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON
D Dedication Application
D Dedication Checklist
D Improvement Application
D Improvement Checklist
D Future Improvement Agreement
D Grading Permit Application
D Grading Submittal Checklist
D Right of Way Permit Application
D Right of Way Permit Submittal Checklist
arid Information Sheet
D Sewer Fee Information Sheet
.NA~~
City of Carlsbad
ADDRESS: 2075 Las Palmas Dr., Carlsbad, CA 92009
PHONE: (619) 438-1161, Ext. 4'-3L.5"
A-4
P:\DOCS\CHKLSn8P0001.FRM REY 04/30/96
2075 Las Palmas Dr.~ Carlsbad, CA 92009-1576 • (619.) 438-1161 • FAX (619) 438-0894
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 st~ndv' 3rdv'
82( D D 1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow b. Property Lines Easements
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
~D D 2. Show on site plan:
A. Drainage Patterns C. Existing Topography
B. Existing & Proposed Slopes
D D 'D 3. Include note: •surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[Per 1985 UBC 2907(d)5].
D
On graded sites, the top of any exterior foundation shall extend above the elevation
of the street gutter at point of discharge or the inlet of an approved drainage device
a minimum of 12 inches plus two percent• (per 1990 UBC 2907(d)5.).
4. Include on title sheet
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses (manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\DCX:s\CHKI..Sl\BP0001.FFM Page 1 of 4
1stv 2ndV DD D
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
3rdV
5. Project does not comply with the following Engineering Conditions of approval for
Project No. ---------------------------------
Conditions were complied With by: ______ _ Date: ___ '------
DEDICATION REQUIREMENTS
D D D 6. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ _______ -pursuant to Code
·section 18..40.030.
Dedication required as follows: ------'---------------
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8-1 /2" x 11" plat map
and submit with a title report. All easement documents must be approved and
. signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Provide the
completed application form and the requirements on the checklist at the time of
resubmittal.
Dedication completed by------------------
IMPROVEMENT REQUIREMENTS
Date: -----
D D D 7~. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds $ -pursuant to Code Section 18.40.040.
Public improvements required as follows: ________________ _
-Please have a reg'istered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a
separate plancheck process through the ~ngineering Department. Improvement
plans must be approved, appropriate securities posted and fees paid prior to
issuance of permit.
Attached please find an application form and submittal checklist for the public
improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal.
Improvement Plans signed by: __________________ _ Date: ---
P:\DOCS\CHKLST\BP0001 .FAM Page 2 of 4 REV 04/30/96
1st./ 2nd,/ 3rd/
DD D
BUILDING PLANCHECK CHECKLIST
7b. Construction of the public improvements may be· deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed on the
· property and processing fee of $ _____________ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
. and approved by the City prior to is~uance of a Building Permit.
Future public improvements required as follows: ________________ _
Improvement Plans signed by: ________ _...,. ____ _ Date: ____ _
D D D 7c. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
~D D
Future Improvement Agreement completed by: ____________ _
-Date: --------
7d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction of
the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the M~nicipal Code.
D D D· Sa. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
D D D Sb. Grading Permit requ.ired. A separate grading plan prepared by a registered Civil
Engineer must be Submitted together with the completed application form attached.
NOTE: The Grading Permit must be issued and rough grading approval obtained prior
to issuance of a Building Permit. · ·
Grading Inspector sign off by: ___________ Date: ____ _
0 . Sc. No Grading Perrnit required.
P:\OOCS\CHKLST\BP0001.FAM · Page 3 of4 REV 04/30/96
BUILDING PLANCHECK CHECKLIST
MISCELLANEOUS PERMITS
1~dv'
0
srdv' fJf'~D 9. A RIG HT-OF;,.WAY PERMIT is required to do work in City Right-of-Way and/or private
work adjacent to the public Right-of-Way. Types of work include, but are not limited
to: street improvements, trees, driveways, tieing into public storm drain, sewer and
water utilities.
Right-of-Way permit required for-----------------------
A separate Right-of-Way permit issued by the Engineering Department is required for
the following: ---------------------------------
10. A SEWER PERMIT is required concurrent with the building permit issuance. The fee
is noted in the fees section on the following page. ,
11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste
Permit Application Form and submit for City approval prior to issuance of a Permit.
Industrial waste permit accepted by: ______ _ Date: ___ _
P:\DOCS\CHKLSnBPOOCl1 .FAM Page 4 of 4 REV 04/30/96
.. . ,, .
ENGINEERING DEPARTMENT ENGINEERING. REVIEW SECTION
FEE CALCULATION WORKSHEET
D Estimate based on unconfirmed information from applicant.
D Calculation based on building plancheck plan submittal.
Addresso?~3&, 'c/ Bldg. Permit No. !'?.8 '7btJ7<fh ~In-. ~
Prepared by: /?7A Jr'.-. Date· _____ Date: ______ _
EDU CALCULATIONS: Li~t ty~ !n9,~q~~~ !ootagesjor ~.Yi~.,!.,./ it) 0 4 • ~ / ~,5'8S w~ 7SJ1s, . , J 51 , , el
Types of Use:"tD~ «A Sq. Ft./Units:75 SJ21l'7;622«} EDU's: L_ ~ ,,.,> W,-,~ Cre '
. Total EDU's: d • 7
ADT CALCULATIONS: List types and square footag8o/~~Jr ~9!t:t>O , / .5 ~
Types of UsJ: ~~~ A./Un1ts:.2.S:'.'~ r{f1Dt1"A0rs: L. ,3J ) whs CrFef.
Total ADT's / 1 4-
'FEES REQUIRED:
PUBLIC FACILITIES FEE REQUIRED O YES O NO (See Building Department for amount)
WITHIN CFO: DYES (no bridge & thoroughfare fee, D NO
reduced Traffic Impact Fee)
~AK-IN-LIEU FEE PARK AREA:. __ _
FEE/UNIT: ___ _
-~FFIC IMPACT FEE
AD Ts/UNITS: j 14: X FEE/ADT:3 4=
~RiDGE ANO THOROUGH~AR~E
ADT's/UNITS: J J X FEE/ADT: -~ ~
~ACIUTIES MANAGEMENT FEE ZONE:_r-__ _
X NO. UNITS: __ _
__ ~ SQ.FT.:___ X FEE/SQ.FT.:
!l2r 5. SEWER FEE
PERMIT N;s EC/6005 ~
EDU's: __ ~ • 7 X FEE/EDU: )8/)b
BENEFIT AREA: F DRAINAGE BASIN:, 5.6
EDU's: d • J X FEE/EDU: ~7 '-J
p~INAGE FEES PLDA.___ HIGH . !.~OW _______ _
~ i.k-ACRES: .
~ SEWER LA TEAAL ($2,500 DEPOSIT)
X FEE/AC: __ _,_
~TERFEE
EDU's: ~• -z . X FEE/EDu;2._40Q
=$ -c9
=$ 3, 8 7 (p
=$ ;?, 50??
=$ 4:)g7(o .,
=$ ;J,373
-c9 =$ ____ _
=$ _ _.:t ..... :J=-----'-
=$ 6_, 480
TOTAL OF ABOVE FEES*: s ~ O; // 3
*NOTE: Thia calculation sheet la NOT a complete llat of all fees which may be due.
. Dedications and Improvements may also be required with Building Permits.
P:\DOC$\MISFORMS\BP0002.FRM REV 01/04/95
~ i \ iJ\
i OJ 1u .s ·<11 0 0 0
.j
' ~
>->->-.c .c .c .... CII (')
'II: 'II: 'II:
.:.: .:.: .:.: CJ CJ CJ OJ OJ OJ .s:: .s:: .s:: (.) (.) (.)
C C C <11 <11 <11 ~ a:
D
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
· Plan Check No. CB t/6-7~6 · · Address 2~'3",G f4ttu~#>
Planner Van Lynch
(Name} ·
. Phone (619) 438-1 1-61 ext. 4325
APN: ~z.__(z-06!--2-6.
Type of Project and Use: ...... I ....... IV@<J: .............. r_ ..... T;;Z;; .......... · -~---------------
Zone: G-VV) Facilities Management Zone: ____ .fr ____ _
CFD(cinttni'iY # ____________ _
:~ (If property ,in,·complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department)
Legend
~ Item Complete
(g) Item Incomplete -Needs your action·
Environmental Review Required: YES NO~ TYPE __ .....;1 __ \ _. .. '
DATE ·oF COMPLETION: ---,-----------.\
L \ I ¼• . 'f. \ \)'
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval .. ... . ...
... -• ~ l
Discretionary Action Required:. YES _ NO ~ TYPE ___ _
APPROVAWRESO.NO. __ ......._ ____ DATE ____ _
PROJECT NO. ____ __
OTHER RELATED CASES: -----------------------------
Compliance with conditions or approval? If not, state conditions which require action.
·Conditions of Apprqva,I ____________________ _
I . t
California Coastal Commission Permit Required: YES NOk
DATE OF APPROVAL: __ ____,.. _______ ____.__
. San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA 92108
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which r~q~ire action.
Conditions of Approval --'----,---------------------,----
lnclusionary Housing Fee required: YES _· __ NO _X, __
(Effective .date of lnclµsionary Housing ,Ordinance.~ May 21, 1993). ' ' . ' " \ ' .. '
Site Plan:
l9"b D 1. Provide a fully dimensioned site plan drawn to scale.. Show: North arrow, property
lines, easements, existing and proposed structures, streets, existing street
improvements, right-of-way width, dimensioned setbacks and existing topographical
'lines.
ri D 2. Provide legal description of property, and assessor's parcel number.
Zoning:
~D D 1. Setbacks:
,J(~ Front:
l ,i ,uU.!i Int. Side:
V"'-o.l l Street Side: ,., Rear: ~ ~t ~:'.g~:~erage:
~ D D 4. Parking:
Required _____ Shown _____ _
Required Shown _____ _
Required Shown _____ _
Required Shown _____ _
Required _____ Shown, _____ _
Required _____ Shown _____ _
Spaces Required ____ Shown _____ _
NO df/J1~(Jel Guest Spaces Required Shown _____ _
DOD Additional Comments1 ·------------------------
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER u,. ~ DATE r~f%
1.
K:\ADMIN\COUNTER\PLANCK.FRM 1-17-96
City of Carlsbad_ 96101
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check 1
Date of Report: Friday, May 24, 1996
Contact Larry Kloha Name
Address
City, State
5355 Mira Sorrento Pl Ste 750
San Diego CA 92121
Bldg. Dept. No. _96~_ -_7_9_6 ___ _ Planning No.
Job Name St.udio Arts Multimed
Job Address 2236 Rutherford
Reviewed by: Mu.it. A~
Ste. or Bldg. No. _1 _17_/9 ___ _
~ Approved -The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, includin~ field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in this. report can result in suspension of permit to
construct or install improvements.
D Disapproved -Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Department Use Only
Review 1st. __ _ 2nd. __ _ 3rd __ _
Other Agency ID
CFDJob#_-'-96"-1-'-0-'-1 __ File# ___ _
2560 Orion Way • Carlsbad, California 92008 • . (619) 931-2,121
· _ .SEP 05 '96 10:52 SMITH CONSULT. ARCH.··:--········~, ..... ,.. -~---.,. 05 •9'5· HORUWITc-.1hr1...Uf<': Cl'\/(.). -~C:.L.• . .)r.:,i.;-.;:-,;, .. ..:. • --..,r,:J;;
"' .. ,. : ; ~~~!(·\~ ~;·.!t~:L::::, . :.>. · · 'no:atrwr1z··1:Avion.~~~N~·JjtinvG
. . . .
-. ·:~ t::;.~~:.·
st it a c· r Q i. ;_ ;.-" c f v'i_ t. :·. c. o tt ~ a\. T f If iZ
_.._... ..u.-.-p.• ',-.. ----
Sl1<.0QTURAL CALCULATIONS
Pfc.OffiC..'1 ':
CONCRl:.i'E s1-ru!NOn-i: AT 1-wr.!NTY EKHff-DA YS: ··-.......... _...,?.,:;:..Sb:>__,._·_ fSI
MASONRY: ORA.De ",N" CQNCP.m 13lOCK 1: ' M ~ -------___ P.St
MORTAR: TYP£ S 1800 PSI
OROtm iooo PSI
n.£u-lFORCINC STE.EL. A-615
STRUCTIJRAL STEEL: A-36
LtJ'MB~R: DOUGLAS f-JR-LA.~Oi
JO!STS
BEAMS AND POS'tS snms
GRAl)E-40:
Glv.D~60:
#2
112.
i:'5 AND LESS (U.O:N.)
tr6 AN!:i LARGER'
ST\JC OR ,~ETTER
SElSM!CFCRCE: ..• /8?.t-/ REPORT OY': ----.. ·------~----------
ROOF I.H;.Af) .~,0AD
R.OOFING
Pr,YWOOD
SOlSl'S
tNSUL. & CLO.
MISC.
SLOPING.
&OQP YYa !.QAU
SLOPlNO
'PLAT '21';.C)f'Sf"
lR!:.~&1.,i'~;,
!l.EP()/ff NO.: ---"·-----
Ft.CORINO
PL'!WOOD
.10151'$
IN$UL. &CLG,
MISC,
'IOTAL =
00.
fl,QQR i JVE LQbD
~,-::fSu;~.
i'NTERlOR
aALC()NY
F..Xfr WAL.KW A Y
----
So~
40 PSF
60 PSP (U.O.~.)
lOO PSP
lNTERJOR
IDCTERlOR
P'~Krf11£»-)
10 PSr.
16 PSF:·
'Ulf'Sr
'Th.cae cilwb.~ ue !united oaly to ihc-ltQ11$ i.nd~dc4 h<;m~ sdca~ bJ 111c. die.at aAd do a.it imply awrov~ of ii!ZY o~ct" ponioA 01'
~·att1.1ctlire ·by lb.Is offioe. Th~ eatetilitiollli are nol "lttld if altctcd m &'.Ir way. o, ~~, accoin(Jlnicd by .a wet siamp !l.nd sipaluic of lhe
~ ~£ R.-c.c,crd. .
----SEP 05 '96 10:53 SMITH CONSULT. ARCH .... ., .. -...---HORO!c/ITt.'··.JH'tLUI< !:.NI.:,. 11:.!..::,01;-i,;:,~-=u·
&rt~ 1<cof' ~<r.>:s.~.s·
(/tJ/1' /1YSTAL.LA-r10H,
11-' .l~
r IJ ~ r;,cc, "') ~ ?oeo' 1r
tdj., '?oBo(9) ;; 2'1-3 11t
+t"'"'
~-~ t,J:; Q_Cf--«;,ye,);. 7!.fOdlt
2-'l,3
Z{J,1; ~ "/, ~.. ze;/e;, -.I-/, ~-f/Ef,!. M~~-01'
..
.SEP 05 '96 10:53 SMITH CONSUi,..,:_. flRCH."''· · ... .,....,.... HOROW ! r.~-I H l"LUK c.r,t;. ! C:(.. •• A)V vO-'+.!: ·Sap 05 '96 . .. p 4/4·i-; (7 10 :L!9 No. ,_;v,., r. J,.,
r .
't,J /,H..B
f . ~--
11se*'
· .... ~
n·
M'" ~3Z.I /#
c( U, "'t
~p~s.~ . . ~ 3~·.ss·ZP
TH£. C:. • ...\ .· ~ E.X.ceJ>iAfiU?-TO
~flr)R."i TH£ 9+lf !Ylt!GH '1., vtJt r
w 1 -rH'!>,Jr .l';i»J·flOtJ.Al. ~~.,.-:
. T Co~Np<:,-~i f;Z().t,t:;Fb
/ F.,-:{ .1~·1.. r.,h)tr l1$fr'\u,./.{'$.
f :-1'3/z = {ff-ff M~ ~ f./N tr.
t..>.:(!1·+Sll-t-.?o):"-z:) • j(.,8 '1t
r'lf o1wr-&.MT.'." ,;:: t>d/f, H
'f J 1,JC,li.:E~(!.. i'-' M~c.,-iT. 7rlf$ / ~
!7'!µfrYIA:t.., J4t..lb lJ/1ttlN L1r'1,-rs-,
.;
' ~i
i ! '
STRUCTURAL ·CALCULATIONS, -
c ,,9~t t;/$/9 z;:, ;R,, tisG /9~H ciF 4 r?ff_/4. · -PROJECT: --=...:-_;:-:...;:;. ________ ..:....:__ _ _,_------,_...,,..'---'-..,_;.;.----,.---~......;;c_...:......;;..____,--'--,.,.._-'--__ __,,_
HGc/21. t/N/T:s t· -_~tf:;:~,: "Bxr~jJ.5/rJ
DESIGN ASSUMPTIONS:
.CONCRETE STRENGTII AT 1WENTY EIGHT DAYS:
MASONRY: GRADE "N" CONCRETE BLOCK F I M =
MORTAR: TYPE S 1800 PSI
GROUT: 2000 PSI
REINFORCING STEEL: A-615
STRUCI'U~ STEEL: A-36
LUMBER: DOUGLAS FIR-LARCH
JOISTS
GRl:'J)E 40:
GRADE 60:
#2
#1
....z.S't?.t?. ·psr
---------PS£
#5 AND LESS (U.O.N.)
#6 AND LARGER
BEAMS AND POSTS
STUDS CONSTRUCTION OR BEITER
SEISMIC FORCE: ':i;:: =. ~; f-REPORT BY: ----'-'--------:--'-'-----"-----------------
WIND FORCE:
B,dQFDEAD LOAD
SI.OPING
ROOFING
PCYWOQD
JOISTS
INSUL. & CLG.
MISC.
TOTAL =
ROOF LIYE r QAD
SLOPING
FLA:r
EL.AI
s;
I• 5"°
t,7
I • ()
I,~
/~ flF
REPORT No.:· _ __;;_ ________ _ SOIL PRESSURE: / tJdcJ f3;::
FLOOR DEAD LOAD WALL DEAD LOAD
lliL EXL
FLOORING 3, b ~ INTERIOR
PLYWOOD '2. ,5 EXTERIOR 16 PSF.
JOISTS -;;,. • I
INSUL. & CLG. ,-,.~
MISC. I·+
TOTAL= l!J f_~ L
FLOOR UVE LQAQ
INTERIOR
BALCONY
EXIT WALKWAY
-40 PSF -t5 () ;?'.s p.
60 PSF (U.O.N.)
. 100 PSF .
These calculations are limited only to the items included herein, selected
by the client and do not imply approval of any other portion· of fae structure by this office.
C/6 'Z/1
,,
. ' . . • ;"" • ~ -·-· f • ---
' ' .
L l-/':.SF '
'70Tr} L .... (ttJ fl.,sp...
/J,9-/27/T/4,.J..5:::. fh--D (75 F-
I q
W -. -
(J .,. ,~_
~ ... ,~, -
~'36o
T --
($d {. I, g 3) =
~77 11.
lb (:, (. 9 J 1..
1S
.., -
--q (1,1;)
)¢-0
SW ..t, +.
'3 ~) '= A.
f)./. 7
f!j-o .Ps~
~ -If, .3 " -
~-:nav er L~ .W Ex~ Glb
~::;. 41)/t,J3 .:. 3511#-/, /,ot!:> ·= 3.3. 1'2J/,
. '
. ·1··. ' .
' ·1-. . .
@ /6:dJ,;.·
I , . f ~ ,_ ,, : .., I ': I:
. ···:.' ..
. ·.. · l
. !
• t { ---~------·-·-. --' • I ·--.-----.... ___ .,, ·-------.
' I ~,--.......... ; --' --• --·-----I -
--------.+---.--------:------· ----~--7-~-;-i J
--·-. ·-··-------~ ---'.---· --·-_.., __ -._ -' --,--:--~---. -·
I
--.• ---··· . ----------. ·--; --::.j
,.
l
----'.---:
-~ -----, ....
,_ ---,-----•·• --+---I• I ; --I -j -. ---·--·-, -
·-~ --------~---; ;
I
-··. --t---t··
···--i-
i ____ ,,___ __
-_; _.., 1_ -
-·-·--.··
' ' ---~ ·-------t--
' '
I .f··-·-·· I.. ' ] I : ' ' • I ' : l 1·. 1· . ·t , _ _.. __ 1_~.'--i!---~-·------1-------J.----·--~---~----l:---f··--,.--+--;---, ----1 ; I ' I ! ( . I • ' ! : I
j' !
1
' f ! I , , • \ , l '--+-~----·-----·•----, ~_.;.--;.1-~--,--,--~...-;.--,-·l-~1i-+-•t ........ :
1
: -.-;.Ii_.___,__: ___ , _____ : ···r-· T I I l l _ __,__i 11 i • -i I· 1 l !
__ ___. __ ,
! ' , _r 1--,--1--r-· _·. _ ..
T ):··? . "
! . l 1 . ,-__ J I 1 ·---·~.--1 ,---,--· ··-··-7-
: I I ' ' : . ! 1 , ! , ! I ' t -l i ~ ! i J ! 1 , .. -------.. --1 -• --t--~-,---........... -........ --:--·-.... ~. --r·---.---------; ~ --· ,--,----. --· . .. . i : ' i :
1 1 t 1 ~~---l~---,-----····~-----r---; I I --~--,-··----------r-· -"---------------~-' I
_J ___ l ________ ··-( -i ____ , ___ ;·····----····--·'--..!·-------'--,--t-----~---' 'I I
t ----.:.----. -.-'.-------------... --··-····-----~---' ;
' '
,.:. :"i! ~1' -' ;-... J ... -: ·: • J
)~ . . , >\•.
I J •
! -l
-il ')
.-,
. :f,1.--,tpJ]TI d 1-i!
' I ... -~-·-.-' .. :--7
'
i
·7:1J TA L
It)
. .. ; ,,. -
' ., 7 ...
v--1 ~ CJ~ ( ~-4)). r ( 11·• ~ 7 -t I 'i) ( Io) ( fj: -f 'f J = ~/~,7/ 7 #.
\ '
i.
;
'S /21-y:-w -:z 6' 3 tt'O It
JZ, F .$, HIIH, -:.. Io (l;j( /d: 7 •fl) f ,36()( 10 • t7) (~ 'j_7 1-j
-t IS !) ( I~ '-i 7 ~) . ~ ::=. 3 7 t1 ·7 ;-~ T-J k..
e =---'3 ,(~_o_ ~
k96 s-
~ '~-: . ·.·· .....
Us (F.-)~ WIO-F ~ ~lei. oec=--1°: PT4-; ___ ;_ -
w/ I -* 1--c.-,;)Nr, ro~ ,t /!;'6rrtH
,,f' . J
I'\
l '. ~ ,: SHEAR WALL SCHED·.ULE
kEF', 16 REF', 8 A B 9
N<aiOI\ SOU'S Al.T!RNAn'. E)(?ANSIO!-l RE:f' BOTTOM PL HAIUIG Of T.H, Of\ ~·s
REF, :l,11 1· _AT f'CAAIOAilot{ ANCttORS AT f'OUHOAilOO ·1·2 ' · HAIUHO . TOf> PL'S at.oa< 'ft>
M~ f ~ATERl>.I. I tfAIUNO · · I.AC(I.) ;1,-cc.(ST) TOCC1l-ER TOP PL S
SH£M WALL ~M O!'I H /J..S ·
}JJ.OW /..8l£.
~ (lB/1'1)
.J
p;p.u..RXS
. (D Sl\JCCO . REF, HOTI;, 1 1/2" /I A,B. o ~-1/2· ,,, Kl:l-11 o ~-16d o 5• 16d o 12· 1,6d o 11· 1eo -.
· , ,;2· C'l'P BO 5d C.H. • 7• • , P~
. (I] · · ~s;a• C'l'P 80) '(8d C.N, o 7") 1/2" fl A.B. o· 72" 112· JI Ka-11 'o 7?"' 16d o 12.· . 16d o 12· \6d o 10·. 50 -\00 SEISI-HC-'MNO ~
1/2" C'l'P BO 6d C,N. o -1,• , m
(I)
[I)
(aJ
[iJ
Ii)
[[)
(!S/A" C'l'P 8-0) ' (8d C.N, • -1,")
1/2." O'l'P BO (BU<I;)) I 5d C,H, o ~·
5/a" O'l'P 80 (BUCO)
t/2" O'l'P 80 (IIS)
(!S/8° C'r1" BO)
1 /2" C'r1" BO (BS)
(5/4" CYP BO)
1/2" ·c'J1" BO (BS)
(BU<O)
5/a• C'r1" BO (BS)
(BU<O) •
Od C.H. • -1,•
6d C.H. • 7"
(Od C.H. o 7")
5d C.H. e.-1,•
(6d C.H. O ~·)
~d C.H. • -1,•
lld C.H. o -1,•
1/2" fl A.B. • M" 1/2" fl KB-II o 56" 1,lld O 10·
1/2" /I A.B.· o ~· 1/2" fl KB-11 o -1,5• t6d o ·e·
1/2" /I A.B, • ~· ,;~-_!, ~-=11 O ~-,ad o s·
I /2" fl A.B, o ,4-0• 1/2" fl KB-II o -1,0• 111d o s·
1j2• fl A,B. • .'.12" 1/2" ,. KD-11 o .'.12° 16d o s·
5/e" fl A.B. o Ml" 5/6" , KB-'11 o Ml" 16d O -4•
5/e" fl A.B. o 4-0• 5/e" fl KB-II o -1,0• Hid o .'.l ·1/2"
16d o 12· I 16d o e· 6.'.l -, 125 SOSMIC-'l'I\NO
1Gd· o 12· I 1sd o 11· 75'-)SO· S£1SMIC-'MHO
'llld O 12· I H!d 011· 88 -175 SEISMIC-WHO
16d O 12· 111d o e· 100 -200 SCISMIC-'MNO
16d o 10· I Hid o ~-125 -250 SEISI.IIC-'n\110
16d o 7• I A.'.15 o 16 ° 150 -JOO .S(ISUIC-Y,\flO
16d O 7." A.'.15 O ·IC" 175 -.'.150 S£1Sl.llC-'MHO
[ID 2...;LAYERS s/a· Cy? I BASE PLY lldOO"
(BU<O) ·FAC£. PLY 8d07" \ /2" fl A.B. ·O .l2" 1/2" fl KB-II o ?2" \6d o 5• 16d O 10· I ),JS O j5• 125 .;,,. 250 I S8SI.IIC-'MNO,
[i) 2.-LAY£RS 5/a" ·C"1" BASE PLY Cid~"
_(BLKO ·as) f'AC£. PLY ed07° 5/e" ,i A.I'!, o 2:4" 5/8" ,. KB-11'.!0 2-1,• ,\6d O 2 1/2" (ST)' 16d o s· A.'.15 O· 10· 250 -500 SCISl.!IC-'MHO,
6IJ rn. ,1,· m cox " • ,. ,;,· , .. ,.. • ... ,;,•, .,_,, • ... '" • ,· • '" • ,,. ,., • ,·
1
,.,
1 1
(al , 3/a· PL-'f cox . . lld o _5• 5/67 ·,, ,.._a, • .'.12~ 5/6~ /I KB.-11 o .32" ,_<$d o -1,• ·1, , 16d ·"_ 7.~ ·' AJS o _.,5• . , . , :32~. .. . _
liil · 3/6~ PL'\' c:Qx ~d o -1,· ... _5L6~__t_>..B_. o J2· _ s_;r,,; KB-no 32· 111d o J 112· 111d or ... .:is o 1~· . Jli{
. Ml I 3/6" PCY COX I. 6d o 3• I. 5/e".,, A.13. o 2-1,· I 5/8" If i<!:l-11_~ ~£ I \fid·_!I 2_1;2· (sT)I 16d o 5• I AJS o 10· I ~02,
trn I . 3/8" Pl.'.f' STR I . I Cid'·-3• ' I ~/_8"_ f A.B. 0 2-1,• 1· 5/t, ,, ,1<!3..:11 0 i-1," + 1,8d O 2· (ST) I \6d O 5• I ,AJ5 0 6~ r 552
(W 3/8~ PLY ·cox, . 6d •· 2,• 5/8" /I A.8. o 2-1,• 5_/~" /I t<B.,.11 o 2-1,• 1/i~x6" o 6". (L) 16d o -1,• A.'.15 o a• ,(p3t,· --R_~' ,1-1o~_+ __ . ,.
6i) 3/8" .Pl.'!' (:pl( (8S) 6d o -1,• . 5/6" /I A.B. o 111• 5/6" " KB-II • Ill" 1/2~xo• o a" (L) 16d o -1,• A.'.15 0 5• 766 -,7£F. -NOTES ... ,6'
~. · 3/6" PLY cox (~$). ed o ,.'.l 1/2· 5/6" JI A.B, o IC" 5/a" fl KB-II O ·16' .· 1/2"xl5" o 5• (L) 16d o -1,• AJS o 5• 07.(l R(r. NOTI:S 4,5
!ill 3/6" PLY -COX (BS). 6d o 3• ~/6" ,,, A.8, o 12• 5/6" " KB-II o 12· t/2"x6' o -4• (L) 20d o 3•' AJ5 ~ s· . ~.6+ REF. NOTES 5,a·-
!i2) 3/a" P.\.Y SlR I (e's) . 6d O J" 5/8° /I A.B. O 12' 5/8" /l Kl:l-11 o 12· 20d o :i· AJ5 o··s· 1100 REF, NOTES 5,0
IUI. .
{Bl I tS/32" Pl.Y cox I ad o .:i· I 5/o· ,, A-B. o 2-1,· I 5/8" ,, KB-11 o i...· I 1Bd o 2· (sr) I 1Gd o ~-I AJS o .e'. I 4qo
fill' I 15/32" P\.Y STR I I 10d • 3• I 5/0" fl A.B. o 16" I 5/8" i, KB-II o 16" I 16d O 2'(ST) I 16d o -4• I AJS O 11· I 665 '10d SHORT (2 1/4")'
~ t!S/32" Pl.Y STR I ad o 2· 5/e" /I A.8. o 111· 5/8" i, KB-II o 16' 1/2'xo· o o· (L) _16d o ~-"A.'.15 o a· . ·7JO Rff. NOTE '. .liil 15/32" Pl.Y cox \Od o 2· 5/6' ,, A.l:l: o 1s· 5/8~ ,, KB-11 o 15· 1;2·xo· o o· (L) 1Gd o +· AJ5 o s· -• 770 · REF. NO~,,
~·;:{J}
-• ·~. l.,: ,;,~
,,,'.
:~ ,,~ ',. ..
. .. ~ ... ~~:-~:
,··
'.
-~
----
~-'
,: ~-· ~· ~ 15/32• f'l.Y STR I 10d o 2• 5/11" /I A.B. o 10• 5/8" / KB-II o 1s· . 1/2"xa· o 5• (l) 16d o -4~-AJ5 o o· ~ 67~ . R£f. NO.rt; 4 -: ::·r
l ,Im . . --·------··--·--· -'• J CHI ~$:,:.,1;/8.1' '.
-" -• • •·-•• -•• • .:,. -,,•. : ·, .. '.-.'' • -.. a'•~ , -" ' • '·\,'I'.:' .\:~:.~\;{?f
.•.. TYP. SHEAR WALL
SCHEDULE NOTES:
1. EXTERIOR· srucco WHERE OCCURS SHALL BE WOVEN WELDED WIRE
LAnl ·'MJH 7 /8" POR1l.AND CEMENT PLASTER Wini· H 11 GA. NAILS
x 1 1/2" LONG x 7 /16" Ji HEAD OR j 16. GA. STAPLE x 7 /8" LONG LEGS.
2. ALL SUPPORTS FOR THE GYP. BOARD TO BE NAILED wrn; COOLER
NAl~S (C.H.) . '
3. ALL PLYWOOD PANEL EDGES TO BE BLOCKED.
4. 3x AT 1.6" sruos, Jx BOTTOM PLATE AND Jx INTERMEDIATE
BLOCKING IS REQUIRED.
5. 4~6 SnJOS, Jx6 TOP AND BOTTOM PLATES & 4x6 BLOCKING
IS REQUIRED.
6. SHEAR WALLS Wini PLYWOOD ON BOnl SIDES; BOTH VERTICAL
ANO HORIZONTAL INTERIOR JOINTS ON OPPOSITE SIDES
OF THE WALL SHALL BE ST AGGEREO.
7, ALL ANCHOR BOLTS TO BE 12 INCHES LO_NG. (MINIMUM A.B.
EMBEDI.IENT TO BE 7 INCHES U.O.N.)
·8. KB-II .DENOTES "HILTI KWIK BOLT-ll'S" (ICBO /14627) WITI-l 4 INCHES
MINIMUM EMBEDMENT, FOR INTERIOR WALL Sl.:lBSTinJTIONS ONLY.
CONTACT E.NGINEER/ARCHITECT FOR EXTERIOR WALL SU8Sll1UTIONS ..
9. 2-ANCHOR SOL TS PER WALL MINIMUM.
10. MINIMUM A.B. SPACING: 1/2" P A.B.'S o 72" o EXTERIOR WALLS.
7/32" p RAMSET .PIN o 32". (ICBC fl639) FOR INTERIOR WALLS
WITH WALL SHEAR LESS nlAN 1008/FT. ONLY.
11. USE COMMON NAILS FOR PLYWOOD. NAILING. GALVANIZED BOX NAILS
CAN-BE SUBS-TITUTED FOR COMMON NAILS.
'
12. @-CONNECTIONS FOR 2ND FLOOR AND A80VE ONLY. USE 4x BLOCKING
BELOW AT WALLS WITH LAG SOL TS OR 16d o 2 1 /2" O.C. OR LESS
(STAGGERED) CONNECTIONS.
. ; ....
' -' ' ~
S_ECTIO_NS-· &
' ~-. -' -~.-;---~·1· : .. ~";: }~
N . -O· · r·-E· S· ·· 1
_. -~-·: ..: :~~,~--·~? ·
--: -' -. -. ' -' ' -.:i~:i,\.,(/??,,'
,,..,.,
I
~Oft;
.,
.JOIST
ix Bl.KC,
A I BOTTOM
l'\.ATE
COWi.
,. Ill.I( • :ii•
fu:o~~
·sHEAR WALL SECTIONS:·
-mi'
..XOiOI\ IOLT (A.A.)/ S(:1-t[P,
J,
A88RE'M TIOHS:
C.N.
BU<D.
(BS)
FNO.
PL
A,8;
~~) REP.
GA.
COOLER .NAILS
BLOC!<EO
BOiH SIDES
FOUNDATION
PLATE.
ANCHOR BOLTS
LAC BOLTS .
STAGGERED
REFERENCE
GAUGE.
PLY.
O't?, • 80,
CONN.
T.N.
(U,O.f:l,)
SCHEO, ·sm , cox el.Kc
I PLYWOOD
GYPSUM
BOARD
CONNECTION
T9E NAIL.. . 'UNLESS OnlER~SE NOTED
SHEAR WALL SCHEDULE STRUCl\JRAL \ --
EX1iaRIOR GRADE PLYWOOD
BLOCKING
MIH.
BU< o.c.
I.IINIMUI-I
BLOC1<.
ON CEN'11'.R
GN15S 1/$'.1· •
.~~,
. : ; . /-~
' -tJ
~H ... ~('13f>t/-)
;/2,,(/~.5 t:49/?/9t::-.!T'/-: ~ ~?,· #/r-T·
.ps-~ . M f-/R-,
/., l ,.,
(/1./ -
~· v-+Iv-
t;J::. '3CJ it/tz-T
O.L·:. 't-o (?sp
!t l l. ~ ~.t; (7.Jr-
Lt"~ Ll?AD ~cJC.-110,-.i
1) (Z = ~ ( ,4 -IS' O) :. ti,, O i ( ~ 'I-4-4--iS (J j -: I{, .. It >'a
~) £ = ~3, I C I+ i) _ ~ S4,7 /o
· ll :: ~ t; ( /-·(J, /6) o /7 ;?.!>·;=
7'oT/f L
W 7 i :: 9-7 C '? ) --=-~ J ti ~ /.rz-T
T't>Tft-L t.-0 ~ ;;).. I~ +Z>9
,
'7.
1
sr il{,if'l>f ·:. ,: ? r: :r tr~,r ' ;
. ' ,,
. '
· · .. . · 1G z . r t:tJ·. i 7-. 4 97 11
M -:;.· ·ff 7 ( ~J.) :. ltJ'f.So fr--/'b,,· ·
I /,. , 44-t1
' \· j ·S=-4f~~
OL.::. f'Jo :: ;)..;~:O 'ft;/
t) lZ · ~ · r ( ,,q -1 Jto) ==-o. t1 i ( ~ >< +.4--1 s~ t>)-= 1,; 7' ~
cA) (2-, :: ~J. I(! f -0o j = 3,f, 7?,
. t. l-:t ;)_ (!) ( I -ct, I 6) .: 17 r'..$ J=.
TtPT,i l. t~/,0-:::.. /7 -I-I tJ = -~ 7 ~...{ r-
vJ rt. -:. · ~ 7 ( .q) : ;). / 6 #If-r
rt) TA-L tJJ =-~lb -;-4 j .::. ~ s 'f' #IF r
M=-
6~ .6 7 ,g (1z)
-4 f-1-
.6.n.,:. ~~ io .--3/'~ . >42,fc Ole-
' 'i
--
I
7~ 7
~(;!)+
'-· ' l .
Sq,(} ( ¥) ".'l,,,
~<!)' (_3"_~)
. "2..-
. !
-·-
-----
l ----. ____ _,,. __ , -_, --'-----
!'
, ____ (-·-----,-----'_.., --I -., ~ ••• • '
' ' ' J
7~ 7/
---!-... ---,----..
! ' '\ ., ·-. ··A. r -. ,.~l?G-/2<-•.. v,,J,,, r. -:·· -LL.J.. . ;.,--,-• ; I ./53 -Mt:lr
l
---,---------------·--·------------------·---------__ _: ______ i-___ : _____ , ____ l ___ l __ _; __ ----. . :If !
·· -=--· ·--·-· '"'-: --· -W -'::7 · ·--·· /.tJJ · (:-~-)· ..... .:. -· ·~-0--__ : L-.7 :-----·-· ~·.
' " 1 i I , ff•\ • i I • ) ' f-} ------;-------------------~-------
i ; . -· ---------~ -~ 1-Ck<'X:r ,'J~)t~ l'?t; )r he>
;)..
---~-~-f __ _
-. ------------------:! ! , --! · -T· ::. ; ··--:---.-·1. -,--··r : ....... , -~ -is··-.-----··.. -r--· ~-·· ..... .
f111t"-Je --=· -1-,;,,· e,. C-rJ, g 9·-· ,~--(.~, '8· s-)( · ~: -+f}-r ~o--(;11.:r) -··
i ---·-----••
' -----7---··1 --~-----------I I
·t.
-M11.-1 ,--· ·· ·· :::· · /~-.;j. .. 7 -r r-'J l;;.
. . ' .... '!:!'. ........ · ..... ======~
V ...... ,,n.,~,
'
-·-·
' . ; '.
I
I ... _!
'
---------. __ ----------·----,.--~----· ---'
j ------------~ -....... _, --------·----'-·· ' ' , I
: ! . :Jo
, •. j
-' ·, -~ ..... -:-....:::.. . :.. -· . ----· -· ----·-~----
\ . i -,-• 1
' I '. '• : ! ',\ ' / I . ___ .,, ___ :_.;&,;.::. .. /'-/'Be-#. -v!N'/ 7 L .. L---·/ $,· A,).~r ·' /N' ~ UoGo
I ./_. • !
i ---·,-----~--------
__ .J __ j __ . ·--~-WL=-~--/~ .. t-;.-).
' . . ' ' '
;'
' --..... ------: -~--·----. '
_., . -... ---_i __ ..:_' -
i
\; --. i·----!-··-·1···· ·-
:;) (6~)(~:~-9 t~(~j)fjf;i~ ··-=---;~~66-~_:_,g; .. ·-
d-
.... -~---~ -hf· .
'-~ ~
[;(l>t;) (;;, 8 r) f-,1o (;).) ·
~ -t-l-Sl) .::
·-...,.---+-..,___.......,! _________ -·--·---------~ ' -. I· ' I
I ' _ __,__, _______ , __ ----~ -·-.
.. --£/--~-.€
r:,1-·:. l
' I ' '
]
----~--~-___ ,..._.., _____ ,_. __ ,----·--~--..... --~-. ------
l I , ----' ---. --=-----. ... ' ~.;.....; ----tl j J_: ____ . ---· ___ .]_~_!_ ---· _! .•
' '
;-l ; /
------+.:-....... -1---f ----.J ---, ___ _
;
• -.---~ ---.i -------·-~. -• • •• : . __.:. __ -' ---.'
' ' I ' ' ! ' -----·--,------·---
·----;--
J_
3 4-/ !it.
:t,
CARLSB IFIED SCHOOL DIST
PUBUCAGEN
JACK & PATRICIA SUDDUTH
1301 FORTSIDE DR
FORT WASHINGTON MD 20744
CARLSBAD FIED SCHOOL DIST
PUBLIC AGENC
CARLS UNIFIED SCHOOL DIST
PUBLIC AGE
NEWPORT BEACH CA · 6.qQ_
MICHAEL J & NANCY CARDOSA
6491 EL CAMINO REAL
CARLSBAD CA 92009
OCEAN BLUFF PARTNERSHIP
4180 LA JOLLA VILLAGE DR 300 .
LA JOLLA CA 92037
MANUEL C & AVELINA HIDALGO
6511 EL CAMINO REAL
CARLSSAb CA 92009
ARIE DEJONG JR
622 E MISSION RD
SAN MARCOS CA 92069
GUYS MOORE
6503 EL CAMINO REAL
CARLSBAD CA 92009
NOBORU & EVELYNTABATA
POBOX943
CARLSBAD CA 92018
_....--1
TERRY R & MARGARET REITER~
6 SADDLEBACK:·RD
~ES PENINSULA C 90274
ROBERT F & CHERYL KEVANE
8480 LA MESA BL VD
LA MESA CA 91941
C;~ IFIED SCHOOL DIST
PUBLIC AGEN '
NEWPORT BEACH
JOSEPH A & BARBARA RUDY ALIS
PO BOX 230267
ENCINITAS CA 92023
-JOHN F & ELENORE LIGUORI
11739 TOERGE DR
LA MIRADA CA 90638
WALLACE G & ELIZABETH AITCHISON
5155 E BOBOLINK LN
PALM SPRINGS CA 92264
GEORGE R BOLTON
6519 EL CAMINO REAL
CARLSBAD CA 92009
GREGORY R & BARBARA NELSON
3664 MARIA LN
CARLSBAD CA 92008
PAUL & PEGGY HADLEY
POBOX12727
PALM DESERT CA 92255
KAISER LIFE INSURANCE
1615 CALLE DE CINCO
LA JOLLA CA 92037
THE V ANDERHEIJDEN FAMILY
I 003 W DONINGTON ST
GLENDORA CA 91741
ROBERT F & CHERYL KEVA€
8480 LA MESA BLY
LAME
D~e
BO~ OF ADMN TR -
4675 M~~HUR CT 1560 £ ,;-,uY'
~T BEP.:CH-Cl,.-2_~~---.
CARNATION PROPERTIES
PO BOX 395
CARDIFF BY THE SEA CA 92007
RONALD C & EVELYN MCKINNEY
4355 HUERFANO A VE
SAN DIEGO CA 92117
POINSETTIA HILLS PARTNERS
111 N ATLANTIC BLVD 102
MONTEREY PARK CA 91754
'~STA REALM
PU~
GUYS MOORE
6503 EL O REAL
C SBAD CA 92009
AVIARA LAND ASSOCIATE~
450 NEWPORT CENTER DR 304
NEWPORT BEACH CA 92660
~·
/
TITLE 24 REPORT FOR:
Studio Arts Multimedia
2236 Rutherford Road, Suite 117-119
Carlsbad, CA
PROJECT DESIGNER:
(619)
REPORT PREPARED BY:
Steve Balderrama, CEPE
Haynal & Co., Inc.
425 West Fifth Street
Escondido, CA 92025
(619) 743-5408
Job Number:
Date: 4/26/1996
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the
Residential and Nonresidential Building Energy Efficiency Standards.
This program developed by Gabel Dodd Ass·ociates (510) 428-0803.
Table Of Contents for Title 24 Report
Cover Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Nonresidential Performance Title 24 Forms ........................... 3
Form ENV-3 Construction Assemblies ...•.............................. 17
\
PERFORMANCE CERTIFICATE OF COMPLIANCE {part 1 of 3)
Run Initiation Time: 14:49:26
Project Name: Studio Arts Multimedia
Address: 2236 Rutherford Road, Suite 117-119
Carlsbad, CA
Designer:
Documentation: Haynal & Co., Inc.
STATEMENT OF COMPLIANCE
PERF-1 page 3 of 21
Runcode: 2875-546993728
jDate: 4/26/1996 I _____ _
!Building Permit No ! _______ _
jchecked by/ Date
I
!COMPLY 24 User 2875
This Certificate of Compliance lists the ~uilding features and performance
·specifications-needed to comply with Title 24, Parts 1 and 6, of the State
Building Code. This certificate applies only to a Building using the
performance compliance approach.
The Principal Designers hereby certify that the proposed building design
represented in the construction documents and modelled for this permit
application are consistent with all other forms and worksheets, specifi-
c~tions, and other calculations submitted with this permit application.
The proposed building as designed meets the energy efficiency requirements
of the State Building Code, Title 24, Part 6, Chapter 1.
1. I hereby affirm that I am eligible under the provisions of Division 3 of
the Business and Professions Code to sign this document as the person
responsible for its p:i;-eparation; and that I am licensed as a civil
engineer, mechanical engineer, electrical engineer or architect.
2. I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Se_ction 5537. 2 of the Business and
Professions Code to sign this document as the person responsible for its
preparation; and that I am a licensed contractor preparing documents for
work that I have contracted to perform.
3. I affirm that I am eligible u_nder the exemption to Division 3 of the
Business and Professions Code by Section _____ of the
Code to sign this document as the person responsible for its
preparation; and for the following reason: ---------------
SCOPE OF COMPLIANCE
ENVELOPE -
Principal Designer
(619)
LIGHTING -
Principal Designer
(619)
MECHANICAL -
Principal Designer
. (619)
(Designers should circle applicable paragraph numbers)
Required Fbrms: ENV-1, ENV-2
Location of Mandatory
Required Forms: LTG-1, LTG-2
Location of Mandato
Required
Location Plans
-+-'--~~~A..!...-f ~_---~b6) 3
{Date) {Circle)
-~-
PERFORMANCE CERTIFICATE OF COMPLIANCE (part 2 of 3)
Run Initiation Time: 1.4 :49: 26
PERF-1 page 4 of 21
Runcode: 2875-546993728
--------------------------------------------------------------------------
Project Name: Studio Arts Multimedia jDate: 4/26/1996
I
Documentation: Haynal & Co., Inc. jCOMPLY 24 User 2875
ANNUAL SOURCE ENERGY USE SUMMARY (KBtu/sqft-yr)
Energy Component
Space Heating
Space Cooling
Indoor Fans
Heat Rejection
Pumps
Domestic Hot Water
Lighting
Receptacle
Process
TOTALS
GENERAL INFORMATION
Conditioned Floor Area:
Glass Area/ Wall Area:
Front Orientation:
Number of Zones:
ZONE INFORMATION Floor
Area
Zone Name (sqft)
----------------------
First Floor -Offices 1728
First Floor -Conf. 301
First Floor -Reception 272
First Floor -Corr/RR 109.5
First Floor -Studio 1600
Second Floor -Offices 2457
Second Floor -Conf. 151
Storage 576
0
Stan,q.ard P:toposed Compliance
Design Design Margin
--------------------------
1.10 0. 71 0.39
35.67 36. 73 -1.07
21.86 14.12 7.73
o.do 0.00 0.00
0.00 0.00 0.00
0.00 0.00 0.00
46.95 4;2.21 4. 73
19.33 19.33 0.00
21.38 21.38 0.00
--------------------------
146.29 134.50 11.80
7604 ~verage Ceiling Height: 9.0
0.34 Average Glazing U-Value: 1.19
deg (N) Number of Stories: 2
8 Number of Occupancies: 5
Display Inst Tailored Process Tailored
Perim. LPD Lighting Loads Vent.
(ft) (w/sf) (watts.) (w/sf) (y/n)
~-----__ ,.,; ___ -----------------------
0 1. 71 0 0 N
0 1.08 0 0 N
0 1.59 0 0 N
0 1.33 0 0 N
0 .1.15 0 6 N
0 1.49 0 0 N
0 1.43 0 0 N
0 0.00 0 0 N
PERFORMANCE CERTIFICATE OF COMPLIANCE (part 3 of 3)
Run Initiation Time: 14:49:26
PERF-1 page 5 of 21
Runcode: 287S-546993728
------------------------------------------------------------------------' Project Name: Studio Arts Multimedia !Date: 4/26/1996
I
Documentation: Haynal & Co., Inc. !COMPLY 24 User 2875
The documentation preparer .hereby certifies that the documentation is
accurate and complete.
DOCUMENTATION AUTHOR
Steve Balderrama, CEPE
(619) 743-5408
~ ~ ,-lt1.e•'iS-1oc-i. ~"
(Signature) (Date)
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agency should pay special attention to the items
specified in this checklist. These items require special written
justification and documentation, and special verification to be used with
the performance approach. The local enforcement agency determines the
adequacy of the justification, and may reject a building or design that
otherwise complies based on the adequacy of the special justification and
documentation submit~ed.
First Floor -Studio Occupancy type of Precision Industrial has been selected
First Floor -Studio 6.00 w/sf Process Load has been Input (See MECH-5)
BUILDING DEPARTMENT APPROVAL OF EXCEPTIONAL FEATURES JUSTIFICATION:
The exceptional features listed in this performance approach application
have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
authorized signature or stamp
CERTIFICATE OF COMPLIANCE -Envelope
Run Initiation Time: 14:49:26
Project Name: Studio Arts Multimedia
Documentation: Haynal & Co., Inc.
Const OPAQUE SURFACES
Assembly Name Type Location/Comments
R-11 Demising Wall(MTL)
R-19 Roof(R-19 on Tile)
Carpeted Slab On Grade
611 Concrete Wall
Hollow Metal Door
FENESTRATION Frame
Orient Panes Type
--------
Left (E) 1 Metal
Left (SE) 1 Metal
Back (S) 1 Metal
Back (SW) 1 ·Metal
Right (W) 1 Metal
Metal
Wood
None
None
None
Exterior Shade OH
-----------------------
None N
None N
None N
None N
None N
ENV-1 page 6 of 21
Runcode: 2875-546993728
!Date: 4/26/1996
I
!COMPLY 24 User 2875
Glazing Type
Note to
Field
-----------------------
Single Tinted
Single Tinted
Single Tinted
Single Tinted
Single Tinted
CERTIFICATE OF COMPLIANCE -Lighting
Run Initiation Time: 14:49:26
LTG-1 page 7 of 21
Runcode: 2875-546993728
--. --------------------------------------.---------------------------------
Project Name: Studio Arts Multimedia jDate: 4/26/1996
I
Documentation: Haynal & Co., Inc. !COMPLY 24 User 2875
-------------------------------------------------------------------------
INSTALLED LIGHTING SCHEDULE
No of
Name Lamp Type Lamps
------------------
Fluorescent 2
Fluorescent 3
Incandescent 1
HID 1
MANDATORY AUTOMATIC CONTROLS
Control
Watts/
Lamp
------
34
34
75
400
Ballast Ballasts/ No of Note to
Type Luminaire Fixt. Field
--------------------------
Standard 1.0 47
Standard 1.5 49
n/a n/a 5
Standard 1.0 4
Note to
Control Location ID Control Type Zone Controlled Field
CONTROLS FOR CREDIT
Control
Control Location ID Control Type
Note to
Zone Controlled Field
CERTIFICATE OF COMPLIANCE -Mechanical (part 1 of 2) MECH-1 page 8 of 21
Run Initiation Time: 14:49:26 Runcode: 2875-546993728
Project Name: Studio Arts Multimedia
Documentation: Haynal & Co., Inc.
JDate: 4/26/1996
I
!COMPLY 24 User 2875
--------------------------·------------------------------------------------
SYSTEM FEATURES
Zone Name
Time Cqntrol
1st Floor
s
Setback Control None
#of Isolation Zones n/a
HP Thermostat
Electric Heat
Fan Control
VAV Min Position
Simul. Heat/Cool
Heat Supply Reset
·cool Supply Reset
Ventilation
OA Damper Control
Economizer Type
Outdoor Air CFM
Heat Equip Type
Make & Model No.
Cool Equip Type
Make and Model
Yes
0.0 KW
Constant Volume
n/a
n/a
Constant Temp
Constant Temp
B ----A
No Economizer
615
Heat Pump
Trane TWA048C300
DX
Zone Name Second Floor
Time Control _._._s __
Setback Control None
#of Isolation Zones n/a
HP Thermostat
Electric Heat
Fan Control
VAV Min Position
Simul. Heat/Cool
Heat Supply Reset
Cool Supply Reset
Ventilation
OA Damper Control
Economizer Type
Outdoor Air CFM
Heat Equip Type
Make & Model No.
Cool Equip Type
Make ~nd Model
Code Tables
Yes
0.0 KW
Constant Volume
nja
n/a
Constant Temp
Constant Temp
B ----A
No Economizer
444
Heat Pump
Trane WCC042F300
DX
1st Floor -Studio
s ----None
n/a
Yes
0.0 KW
Constant Volume
n/a
n/a
Constant Temp
Constant Temp
B
A ----No Economizer
240
Heat Pump
Trane WCD075C300
DX
-------------------. --------------,~ ------------"---
Time Control
S:Prog Switch
O:Occ Sensor
M:Man Timer
Ventilation
B:Air Balance
C:OA Cert.
· M:OA Measure
D:Demand Cont
N:Natural
OA Damper
A:Auto
G:Gravity
Note to
Field
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I I
I
I
I
I
I
I
I
I
I
I
I
CERTIFICATE OF COMPLIANCE -Mechanical (part 2 of 2) MECH-1 page 9 of 21
Run Initiation Time: 14:49:26 Runcode: 2875-546993728
Project Name: Studio Arts Multimedia
Documentation: Haynal & Co., Inc.
!Date: 4/26/1996
I
jCOMPLY 24 User 2875
-------------------------------------,-------------------------------------
DUCT INSULATION
System Name
-----------------------
Trane TWA048C300
.Trane WCD075C300
·Trane WCC042F300
PIPE INSULATION
System Name
Domestic Hot Water
Trane TWA048C300
Type Duct Location
--------------------------
Heating Ducts in Attic
Cooling Ducts in Attic
Heating Ducts in Attic
Cooling Ducts in Attic
Heating Ducts in Attic
Cooling Ducts in Attic
Insul
Pipe Type Required
y / N
y / N
NOTES TO FIELD -For Building Department Use Only
Duct Tape
AUowed
-------
y I N
y I N
y I N
y I N
y I N
y I N
Insul
R-Val
4.2
4.2
4.2
4.2
4.2
4.2
Note to
Field
-------
Note to
Field
ENVF.:LOPE COMPLIANCE SUMMARY -Performance (part 1 of 3)ENV-2 page 10 of 21
Run Initiation Time: 14:49:26 Runcode: 2875-546993728
-------------------------------------------------------------------------
Project Name: Studio Arts Multimedia
.Documentation: _Haynal & Co., Inc.
GENERAL INFORMATION BY ZONE
Zone Name Occupancy
---------------------------------------------
First Floor -Offices Office
First Floor -Conf. Convention/Conference
First Floor -Reception Lob];)y (Office)
First Floor -Corr/RR Corridor/Restroom
First Floor -Studio Precision Industrial
Second Floor -Offices Office
Second Floor -Conf. Convention/Conference
Storage Unconditioned
Total
jDate: 4/26/1996
I
jCOMPLY 24 User 2875
Flr Floor Display
No Area Volume Perim.
-------------
1 1728 15552 0
1 301 2709 0
1 272 2448 0
1 1095 9855 0
1 1600 14400 0
2 2457 22113 0
2 151 1359 0
1 576 4608 0
8180
ENVELOPE COMPLIANCE SUMMARY -Perfo~mance (part 2 of 3)ENV-2 page 11 of 21
Run Initiation Time: 14:49:26 Runcode: 2875-546993728
Project Name: Studio Arts Multimedia
Documentation: Haynal & Co., Inc.
jDate: 4/26/1996
I
jCOMPLY 24 User 2875
OPAQUE SURFACES Act Solar
Type Area U-Val Azm Tilt Gains Form 3 Reference Location/Comments
Wall
Wall
Wall
Slb
Wall
Wall
wall
Slb
Wall
Wall
Wall
Slb
93 0.752 180
18 0.752 225
180 0.192 Int
1728 0.134 0
12 0.752 90
66 0.752 180
12 0. 752 270
301 0.134 0
15 0.752 135
123 0.752 180
15 0.752 225
272 0.134 0
Wall 171 0.752 0
Wall 204 0.192 Int
Slb 1095 0.134 0
Wall 609 0.192 Int
Roof 1600 0.043 O
Slb 1600 0.134 0
Wall 198 0,752 180
Roof 2457 0.043 O
Roof 151 0.043 o
90
90
90
180
90
90
90
180
90
90
90
180
90
90
1.80
90
22
180
90
22
22
Yes
Yes
No
No
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
611 Concrete Wall
611 Concrete Wall
R-11 Demising Wall(MTL)
Ca~eted Slab On Grade
6 11 Concrete Wall
First Floor -Offices
First Floor -Offices
First Floor -Offices
First Floor -Offices
First Floor -Conf.
6 11 Concrete Wall First Floor -Conf.
6 11 Concrete Wall First Floor -Conf.
Carpeted Slab On. Grade First Floor -Conf.
p" Concrete Wall First Floor -Reception
611 Concrete Wall First Floor -Reception
6" Concrete Wall First Floor -Reception
Carpeted Slab On Grade First Floor -Reception
6" Concrete Wall First Floor -Corr/RR
R-11 Demising Wall(MTL) First Floor -Corr/RR
Carpeted Slab On Grade First Floor -Corr/RR
R-11 Demising Wall(MTL) First Floor -Studio
R-19 Roof(R-19 on Tile) First Floor -Studio
Carpeted Slab On Grade First Floor -Studio
6" Concrete Wall Second Floor -Offices
R-19 Roof(R-19 on Tile) Second Floor -Offices
R-19 Roof(R-19 on Tile) Second Floor -Conf.
ENVELOPE COMPLIANCE SUMMARY -Performanqe (part 3 of 3)ENV-2 page 12 of 21
Run Initiation Time: 14:49:26 Runcode: 2875-546993728
Project Name: Studio Arts Multimedia !Date: 4/26/1996
I
Documentation: Haynal & Co., Inc. !COMPLY 24 User 2875
-----. -------------------------------------------------------------------
FENESTRATION SURFACES SC
Act Glass
# Type Area Frame Div U-Val Azm Tilt Only Location/Comments
----------------------------------
1 Wdw Back (S) 36.0 Metal No 1.19 180 90 0. 71 First Floor -Offices
2 Wdw Back (S) 99.0 Metal No 1.19 180 90 0.71 First Floor -Offices
3 Wdw Back (SW) 54.0 Metal No .1.19 225 90 o. 71 First Floor -Offices
4 Wdw Left (E) 36.0 Metal No 1.19 90 90 0. 71 First Floor -Conf.
5 Wdw Back (S) 54.0 Metal No 1.19 180 90 0.71 First Floor -Conf.
6 Wdw Right (W) 36.0 Metal No 1.19 270 90 0. 71 First Floor -Conf.
7 Wdw Left (SE) 45.0 Metal No 1.19 135 90 0. 71 First Floor -Reception
8 Wdw Back (S) 81. 0 Metal No 1.19 180 90 0. 71 First Floor -Reception
9 Wdw Back (SW) 45.0 Metal No 1.19 225 90 0. 71 First Floor -Reception
10 Wdw Back ·(S) .108. 0 Metal No 1.19 180 90 0.71 Second Floor -Offices
11 Wdw Back (S) 90 .. 0 Metal No 1.19 180 90 o. 71 Second Floor -Offices
12 Wdw Back (S) 180.0 Metal NQ 1.19 180 90 0. 71 Second Floor -Offices
13 Wdw Right (W) 36.0 Metal N6 1.19 ~70 90 o. 71 Second Floor -Offices
OVERHANGS/SIDE FINS
--Window-------Overhang---------Left Fin------Right Fin--
# Type Ht Wd Len Ht LExt RExt Dist Len Ht Dist Len Ht
-----------------------------------------
LIGHTING COMPLIANCE SUMMARY -Performance
Run Initiation Time: 14:49:26
LTG-2 page 13 of 21
Runcode: 2875-546993728
·---. ---------------------------------------------------------------------
Project Name: Studio Arts Multimedia
·Documentation: .Haynal & Co., Inc.
ACTUAL LIGHTING POWER
Name Description
No of
Lumin
48 11 T-12 Low Watt /2 Lamp 47
48 11 T-12 Low Watt /3 Lamp (Tandem) 49
75w Recessed Incandescent 5
400w Metal Halide 4
jDate: 4/26/1996
I
jCOMPLY 24 User 2875
Watts Total
per Default Watts
-------
72. 0 y 3384 --108.0 y 5292 --75.0 y 375 --461. 0 y 1844 --
SubTotal 10895
Less Control Credits (LTG-3) o
Totai Proposed Watts 10895
* If not CEC Default value, please provide supporting documentation.
MODELLED LIGHTING POWER BY ZONE Modelled
Floor LPD Total Tailored
Zone Name Occupancy Area (w/sf) (watts) (watts)
---------'-------------------------------------------------------
First Floor -Offices Office 1728 1.708 2952 0
First Floor -Conf. Convention/Conference 301 1.076 324 0
First Floor -Reception Lob};)y (Office) 272 1.588 432 0
First Floor -Corr/RR Corridor/Restroom_ 1095 1.329 1455 0
First Floor -Studio Precision Industrial 1600 1.153 1844 0
Second F.loor -Offices Office 2457 1.495 3672 0
Second Floor -Conf. Convention/Conf~rence 151 1.430 216 0
--------------------
TOTALS 7604 1.433 10895 0
* Note: Tailored Allotment requires supporting documentation on form LTG-4.
MECHANICAL EQUIPMENT ZONINGSUMMARY -Performance
Run Initiation Time: 14:49:26
MECH-2 page 14 of 21
Runcode: 2875-546993728
----------------------------------------·-------------------------------
Project Name: Studio Arts Multimedia
Documentation: Haynal & Co., Inc.
SYSTEM/ZONING SUMMARY
System/Zones Served
1st Floor
First Floor -Offices
First Floor -Conf.
First Floor~ Reception
First Floor -Corr/RR
1st Floor -Studio
First Flo9r -Studio
Storage
Second Floor
Second Floor -Offices
Second Floor -Conf.
Central/Zonal System
Trane TWA048C30b
Trane WCD075C300
Trane WCC042F300
jDate: 4/26/1996
I
!COMPLY 24 User 2875
System Type
Split Heat Pump
No
Sys
2
Packaged Heat Pump 2
Packaged Heat Pump 2
MECHANICAL EQUIPMENT SUMMARY -Performance
Run Initiation Time: 14:49:26
Project Name: Studio Arts M'µltimedia
Documentation: Haynal & Co., Inc.
CENTRAL SYSTEM SUMMARY
Sys No
MECH-3 page 15 of 21
Runcode: 2875-546993728
jDate: 4/26/1996
I
jCOMPLY 24 User 2875
No System Name System Type Sys Economizer Type
1
2
3
Trane WCD075C300
Trane WCC042F300
Trane TWA048C300.
CENTRAL SYSTEM RATINGS
Packaged Heat Pu 2
Packaged Heat Pu 2
Split Heat Pump 2
No Economizer
No Economizer
No Economizer
Sys-------Heating----------------------------------Cooling-----------
No Type Output Aux KW EFF Type Output Sensible EER SEER
. -----. -------------------·---------------------
1 Heat Pump 71000 0.0 O.QO DX 71000 53250 8.90 n/a
2 Heat Pump 42000 0,0 6.60 DX 41500 31125 9.20 9.70
3 Heat Pump 43500 o·. o ·1.10 DX 46500 34900 8.90 10.00
CENTRAL FAN SUMMARY ------------Supply Fa:h --,----_,_ ---Return Fan
Sys
No Fan Type
---------. -----
1 Constant Volume
2 Constant Volume
3 Constant Volume
.ZONAL FAN $UMMARY
Zone Name
None
Motor Location CFM BHP
----_,_ -----------·-----
Draw-Thrdugh 2500
Draw-Through 1400
Draw-Through 1600
---------Zonal Fan
Mtr
No CFM BHP Eff
0.49
0.28
0.31
Drv
.Eff
Mtr Drv Mtr Drv
Eff Eff CFM BHP Eff Eff
---
66 100 None
64 100 None
64 100 None
-------Exhaust Fan
Mtr
No CFM BHP Eff
---
Drv
Eff
MECHANICAL VENTILATION -Performance
Run Initiation Time: 14:49:26
Project Name: Studio Arts Multimedia
Documentation: ·Haynal & Co., Inc.
MECH-4 page 16 of 21
Runco'de: 2875-546993728
jDate: 4/26/1996
I
!COMPLY 24 User 2875
---. -----------------------------------------------------------------------
VENTILATION SUMMARY BY ZONE Tran
Floor sqft CFM Dsg Min sfer
Zone Name T Occupancy Area /Occ /Occ CFM CFM CFM
------------------------------·------------
First Floor -Offices Of.fice 1728 130 15.0 199 259 60
First Floor -Conf. Convention/Con 301 is 15.0 301 151
First Floor -Reception Lobby (Office) 272 130 15.0 31 41 9
First Floor -Cor:i::/RR Corridor/Restr 1095 .130 15.0 126 164 38
F;i.rst Floor -Studio Precision Indu 1600 130 15.0 185 240 55
Second Floor -Offices Office 2457 130 15.0 284 369 85
Second Floor -Conf. Convention/Con 151 15 15.0 151 76
------
TOTALS 1277 1299
WARNING -Total Design Mechanical Ventilation is less than Minimum Required
Tailored OA {T=*) requires supporting documentation on MECH-5, Tailored
Ventilation and Process Loads Worksheet
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Studio Arts Multimedia
ENV-3 page 17 of 21
!Date: 4/26/1996
Documentation: Haynal & Co., Inc.
COMPONENT DESCRIPTION
. ------------------------------
Sketch of Construction Assembly
ASSEMBLY U-VALUE
Construction Components
Outside Air Film
1, Gypsum or Plaster Board
2. Insulation, Mineral Fiber, R-11
3. Gypsum or Plaster Board
4.
5.
6.
7.
8.
9.
Inside Air Film
I
!COMPLY 24 User 2875
Assembly Name: R-11 Demising Wall(MTL)
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing Material: Metal
Fra111ing Spacing: II 0.C.
Framing Percent: 15.0 %
Absorptivity: 0.70
Roughness: Smooth Plaster, Metal
Th R-Value
Fr (in) Cavity Frame
0.17 0.17
0.500 0.45 0.45
* 3.500 11.00 11. 00
0.500 0.45 0.45
0.68 0.68
Unadjusted R-Values 12.75 0.00
Weight:
Heat Capacity:
4.3 lb/sqft
1.11
TOTAL U-VALUE = 0.192
=====
TOTAL R-VALUE = 5.20
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Studio Arts Multimedia
ENV-3 page 18 of 21
!Date: 4/26/1996
Documentation: Haynal & Co., Inc.
COMPONENT DESCRIPTION
I
I
I
I
I
I
I I
I
I
I
Sketch of Construction Assembly
ASSEMBLY U-VALUE
Construction Components
I
!COMPLY 24 User 2875
Assembly Name: R-19 Roof(R-19 on Tile)
Assembly Type: Roof
Assembly Tilt: 22 deg (Tilted Up)
Framing Material: Wood
Framing Spacing: II 0.C.
Framing Percent: 10.0 %
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Th R-Value
Fr (in) Cavity Frame
-----------------------------------------~---------------------------------
Outside Air Film. 0.17 0.17
1. Roofing, Built-Up 0.375 0.33 0.33
2. Membrane, Vapor-Permeable Felt 0.010 0.06 0.06
3. Plywood 0.500 0.62 0.62
4. Air Space * 6.000 0.80 5.94
5. Insulation, Mineral Fiber, R-19 6.000 19.00 19.00
6. Acoustical Tile, Interior Finish 0.500 1.43 1.43
7.
8.
9.
Inside Air Film 0.61 0.61
---------------------------------------------------------------------------
Unadjusted R-Values 23.02
ADJUSTMENT FOR FRAMING
(1 /23.02) X (0.90) + (1 /28.16) X (0.10)
Weight:
Heat Capacity:
6.3 ll?/sqft
2.13
0.043
TOTAL U-VALUE =
TOTAL R-VALUE =
28.16
0.043
=====
23.45
PROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 19 of 21
------------------------------------------------------------------------
Project Name: Studio Arts Multimedia
_Documentation: Haynal & Co., Inc.
!Date: 4/26/1996
I
!COMPLY 24 User 2875
---------------------------------------------------------------------------
COMPONENT DESCRIPTION
------------------------------
I I
I
I
I
I
I I
I
I
I
I
I I
I
I
I
I
I I
I
I
Sketch of Construction Assembly
ASSEMBLY U-VALUE
Construction Components
Assembly Name: Carpeted Slab On Grade
Assembly Type: Floor
Assembly Tilt: 180 deg (Horizontal Floor)
Framing Material: None
Framing Spacing: 11 O.C.
Framing Percent: 0.0 %
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Th R-Value
Fr (in) Cavity Frame
--------------½------------------------------------------------------------
Outside Air Film 0.17 0.17
1. Earth 24.000 4.00 4.00
2. Concrete, 140 lb, Not Dried 3.500 0.28 0.28
3. Flooring, Carpet and Fibrous Pad 0.250 2.08 2.08
4.
5.
6.
7.
8.
9.
Inside Air Film 0.92 0.92
Unadjuste~ R-Values 7.45 7.45
ADJUSTMENT FOR FRAMING
(1 / 7.45) X (1.00) + (1 / 7.45) X (0.00)
Weight:
Heat Capacity:
210.9 1:b,/sqft
42.l~
= 0.134
TOTAL U-VALUE = 0.134
=====
TOTAL R-VALUE = 7.45
=====
PROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 20 of 21
]?roj-ect Name: Studio Arts Multimedia jDate: 4/26/1996
Documentation: Haynal & Co., Inc.
COMPONENT DESCRIPTION
I
I
I
I
I
I
I I
I
I --I
Sketch of Construction Assembly
ASSEMBLY U-VALUE
Construction Components
Outside Air Film
1. Concrete, 140 lb, Not Dried
2.
3.
4.
5.
6.
7.
8.
9.
Inside Air Film
ADJUSTMENT FOR FRAMING
I
!COMPLY 24 User 2875
Assembly Name: 6" Concrete Wall
Assembly Type: Wall
Assembly Tilt: 61 deg {Tilted Up)
Frami~g Material: None
Framing Spacing: "o.c.
Framing Percent: o.o %
Absqrptivity: 0.70
Roughness: Concrete, Asph. Shingles
Th R-Value
Fr {in) Cavity
6.000
Unadjusted R-Values
0.17
0.48
0.68
1.33
Frame
0.17
0.48
0.68
1.33
(1 / 1.33) x {1.00) + (1 / 1.33) x (0.00) 0.752
Weight:
Heat Capacity:
70.0 lb/sqft
14.00
TOTAL U-VALUE = 0.752
=====
TOTAL R-VALUE = 1.33
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Studio Arts Multimedia
ENV-3 page 21 of 21
!Date: 4/26/1996
Documentation: Haynal & Co., Inc.
COMPONENT DESCRIPTION -------------------------------
I
I
. I
I
I
I
I
I
I
I
I
I I I I I
I
I
I
I
I
I
Sketch of Construction Assembly
ASSEMBLY U-VALUE
Construction Components
outside Air Film
1. Steel
2. Air Space
3. Steel
4.
5.
6.
7.
8.
9.
Inside Air Film
ADJUSTMENT FOR FRAMING
I
!COMPLY 24 User 2875
Assembly Name: Hollow Metal Door
Assembly Type: Door
Assembly Tilt: 90 deg (Vertical)
Framing Material: None
Framing Spacing: 11 o.c.
Framing Percent: o.o %
Absorptivity: 0.70
Roughness: Smooth Plaster, Metal
Th R-Value
Fr (in) Cavity
0.001
1. 750
0.001
Unadjusted R-Values
0.17
0.00
0.87
0.00
0.68
1. 72
Frame
0.17
0.00
0.87
0.00
0.68
1. 72
(1 / 1.72) X (1.00) + (1 / 1.72) X (0.00) 0.581
Weight:
Hec;tt Capacity:
0.1 11;:,/sqft
0.01
TOTAL U-VALUE = 0.581
=====
TOTAL R-VALUE = 1.72
MANDATORY REQUIREME~TS
ENVELOPE MANDATORY MEASURES (NONRESIDENTIAL)
1. Exterior manufactured doors, windows, and fenestration products shall meet the infiltration and U-value certification requirements
of Section 116{a).
2. Site-construced doors, skylights, and windows shall be caulked and weather-stripped per Section 116(b).
3. All joints and openings which are potential sources of air leakage shall be caulked, gasketed, weather-stripped or otherwise sealed to
limit infiltration and exfiltration per Section 117.
4. Certified insulation materials per Section 118(a).
5. Urea Formaldehyde foam insulation installed per Section 118(b).
6. Insulation installed to meet flame spread and smoke density requirements per Section 118(c).
LIGHTING MANDATORY MEASURES
1. Each enclosed area shall have independent controls (per Section 131(a) and exceptions).
2. Lighting shall be uniformly reducible by one half in areas which are greater than 100 sf, exceed 1.2 watts/sf, and have more than one
luminaire (per Section 131(b) and exceptions; exceptions include lights in corridors).
3. Daylit areas larger than 250 sf shall be separately_controlled and uniformly reducible by one half (per Section 131(c) and exceptions).
4. Separately metered spaces 5,000 sf or greater shall have automatic shutoff controls (per Section 131(d) and exceptions).
5. Display lighting shall be separately switched on circuits that are 20 amps or less (per Section 131(e), no exceptions).
6. Exterior lighting controlled from a lighting panel within the building shall be automatically controlled (per Section 131(:f) and
exceptions).
7. Pairs of one-lamp and three-lamp fluorescent luminaires shall be tandem-wired where reasonable (per Section 132 and exceptions).
SERVICE WATER HEATING SYSTEMS
1. Temperature controls and recirculating pump controls shall meet the requirements of Section 113(a) & (b).
2. Flow rates and temperature controls for public lavatories shall meet the requirements ofSection 113{b)3.
3. Unfired service water heater storage tanks and backup tanks for solar water heating shall comply with Section 113{b)4.
MECHANICAL AND PLUMBING MANDATORY MEASURES
Equipment and Systems Efficiency:
1. HV AC and service water heating equipment shall meet Appliance Efficiency Regulations, per Sections 111 and 112.
2. Piping, except those conveying fluids at temperatures between 60 and 105 degrees F, or within HV AC equipment, shall be insulated
in ac;cordance with Section 123.
3. Air handling duct systems shall be sealed in accordance w1th the SMACNA HV AC Ducts Construction Standards, Metal and
Flexible, 1985, per Section 124(a) and (b). Ducts shall be installed and insulated as provided in UMC, Chapter 10.
4. Pilot lights shall not be installed for natural gas central furnaces, and pool and spa heaters, per Section 115.
Ventilation
1. Every space in a building shall be designed to have outdoor air ventilation according to Section 121(a), (b) and (e).
2. Operation and control of outdoor air shall meet the time-of-occupancy and pre-occupancy requirements of Section 121(c).
3. When a return plenum is used to distribute outdoor air to a covered HV AC unit, the ducted discharge shall be in accordance with
Section 121(d).
4. Systems shall meet the completion and balancing requirements of Section 121(:f).
Controls
1. Each space conditioning zone shall be controlled by an individual thermostatic control that responds to temperature within the
zone. Heating shall be adjustable down to 55 degrees or lower, and cooling shall be adjustable up to 85 degrees or higher. The
control shall provide a dead-band of 5 degrees between heating and cooling. Section 122(a) and (b).
2. Heat pumps with supplementary electric resistance heaters shall have controls per Section 112(b).
3. Each Space conditioning system shall be installed with an automatic time switch, able to shut off operation during off-hours of up
to four hours, per Section 122(e)1.
4. Thermostat setup and setbaclc controls are required if the summer design dry bulb temperature is more than 99 degrees F, or if the
winter design temperature is less than 33 degrees, per Section 122(e)2, and its exceptions.
5. Outdoor air supply and exhaust equipment shall be installed with dampers that automatically close during periods of non-use for the
areas served by the equipment, per Section 122(:f).
6. Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be
designed, installed, and controlled to serve isolation areas, per Section 122(g).