Loading...
HomeMy WebLinkAbout2245 CAMINO VIDA ROBLE; ; 79-4190; PermitMOTEL NO.' BUILDING PERMIT APPLICATION City of CARLSBAD, CALIFORNIA 92008 Applicant to complete numbered spaces only. PnOHC 729~1lOl Permit No. COMPENSATION INS. CARRIER MAIL ADDRESS USE OP BUILDING NO. BDRMS. D REPAIR D MOVE D REMOVE8 Class of work: D NEW D ADDITION D ALTERATION NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB- ING, HEATING. VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 120 DAYS OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM-MENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THISAPPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THISTYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SICN*TUBE IIED AGENT SI6NATUBE OP OWHEH (IT OWNEB BUILDER) Special Approvals PLANNING DEPT, HEALTH DEPT. FIRE DEPT. SOIL REPORT OTHER (Specify) ENGINEERING DEPT. WATER DEPT. Required Received Not Required WHEN PROPERLY VALIDATED (IN THIS SPACE} THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK.M.O.CASH PERMIT VALIDATION CK.M.O-CASH TOTAL FEES $. •*'. PLUMBING PERMIT APPLICATION City of CARLSBAD, CALIFORNIA 92008 Applicant to complete numbered spaces only. PnOHe 729-1181 Permit No.S/ "* JOB ADOR ESS u fif MAIL ADDRESS — — J / V ^4 3 ^w STATE LIC. MO. ARCHITECT LICENSE NO. MAIL ADDHESS LICENSE HO. 8 Classofwork:D ADDITION D ALTERATION REPAIR S Describe work: PERMIT FEES No.Type of Fixture or Item Fee SPECIAL CONDITIONS:WATER CLOSET (TOILET) BATHTUB LAVATORY (WASH BASIN) SHOWER KITCHEN SINK & DISP. DISHWASHER PLANS CHECKED BY SSUANCE BV LAUNDRV TRAY CLOTHES WASHER WATER HEATER NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 120DAYS.OR IFCONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THEPROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATINGCONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. URINAL DRINKING FOUNTAIN FLOOR—SINK OR DRAIN SLOP SINK GAS SYSTEMS, NO. OUTLETS WATER PIPINGS TREATING EQUIP- WASTE INTERCEPTOR VACUUM BREAKERS LAWN SPRINKLER SYSTEM WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK.M.O.CASH INSPECTOR ELECTRICAL PERMIT APPLICATION City of CARLSBAD, CALIFORNIA 92008 PA.,,?tj Applicant to complete numbered spaces only. Phone 729-1181 Permit No. JOB ADDRESS 2245 (OLcfe. £) Onto Vtta JtotO* . LEBALIDEICR.([ SEE ATTACHED SHEET) MAIL ADDRESS CONTRACTOR MAIL ADDRESS Corporation 650C|)p«rSt..KwwuHxfck L CENSE NO, STATE CtTY 85046 17128 ARCHITECT OR DESIGNER MAIL ADDRESS LICENSE NO. MAIL ADDRESS L CENSE NO. COMPENSATION INS. CARRIER MAIL ADDRESS USE OP BUILDING 8 Clwjofwork: t^NEW Q ADDITION D ALTERATION D REPAIR -•» fc. 9 Describe work: SPECIAL CONDITIONS: PERMIT FEES ISSUANCE OF EACH PERMIT No.Each Fee 00 APKl£<fnON ACCEPTED BY: ' PLANS CHECKED 6Y ^fl- bR ISSIJANCE B N EW CONSTRUCTION, FOR EACH AMPERES OF MAIN SERVICE, SWITCH, FUSE OR BREAKER .25 00 6 NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYb AT ANY TIME AFTER WORK IS COM MENCED. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THISAPPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THISTYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOTPRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THEPROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATINGCONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. NEW SERVICE ON EXISTING BLDG. FOR EA. AMPERE OF INCREASE IN MAIN SERVICE, SWITCH, FUSE OR BREAKER REMODEL, ALTERATION, NO CHANGE IN SERVICE, FOR EA. AMPERE OF INCREASE TEMP. SERVICE UP TO AND INCLUD- ING 200 AMP. TEMP. SERVICE OVER 200 AMP. PER 100 PERMIT FEE ICNATURE OF OWNER H* OWNER •UlLPtRl '°*T" 300 00 302 00 WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK.M.O,CASH PERMIT VALIDATION CK.M.O.CASH INSPECTOR REQUEST F INSPECTOR OWNER. ADDRESS FOUNDATION REINFORCING STEEL MASONRY GROUT - GUNITE FLOOR AND CEILING FRAME SHEATHING *.FRAME EXTERIOR LATH INSULATION INTERIOR LATH OR DRYWALL FINAL O UNDERGROUND PLUMBING n UNDERGROUND WATER d ROUGH PLUMBING SEWER AND PL/CO CH TUB OR SHOWER PAN d GAS TEST ?«*>«•• ' 'LlnifLTTl ItlCAL CD TEMPORARY SERVICE CH ELECTRIC UNDERGROUND d ROUGH ELECTRIC CD POOL BONDING CH ELECTRIC SERVICE Q CEILING HEAT D G.F.I. D SMOKE DETECTOR d FINAL MISCELLANEOUS CD PLENUM AND DUCTS CD COMBUSTION AIR a PATIO SIGN ^RADING CD DRIVEWAY CD CONDITIONE CH REFER PIP d FINA YSTEMS WE ONES THURSDAY D FRIDAY SPECIAL INSTRUCTIONS REQUESTED BY_.PHONE NO.. PERSON TAKING REPORT. REQUEST FOR INSPECTION iMSPFPTnp f^>tr\r~~~ PERMIT OWNER TIME:. ^3rf BUILDING CD FOUNDATION a REINFORCING STEEL a MASONRY C GROUT-GUNITE L"J FLOOR AND CEILING FRAME CJ SHEATHING D FRAME CD EXTERIOR LATH CD INSULATION C3 INTERIOR LATH OR DRYWALL CD FINAL ELECTRICAL ED TEMPORARY SERVICE Cl ELECTRIC UNDERGROUND a ROUGH ELECTRIC d POOL BONDING Cl ELECTRIC SERVICE d CEILING HEAT D G.F.I. E3 SMOKE DETECTOR a FINAL PIIIMRIMtt UNDERGROUND PLUMBIN nUNDERGROUND WATER O ROUGH PLUMBING tZ) TOP OUT PLUMBING CD SEWER AND PL/CO TUB OR SHOWER P CH GAS TES O WATER HEAT FINAL D WEDNESDAY MISCELLANEOUS CD PLENUM AND DUCTS d COMBUSTION AIR a PATIO D SIGN CD GRADING DRIVEWAY CONDITIONED AIR SYSTEMS REFER PIPING FINAL READY FOR SPECIAL INSTRUCTIONS. THURSDAY D FRIDAY REQUESTED BY PHONE NO.. » PERSON TAKING REPORT REQUEST FOR INSPECTION INSPECTOR. OWNER ;_ PERMIT NO.. TIME: DATE: ADDRESS. BUILDING CD FOUNDATION CD REINFORCING STEEL C3 MASONRY D GROUT -GUNITE CD FLOOR AND CEILING FRAME CD SHEATHING CH FRAME CD EXTERIOR LATH C] INSULATION CD INTERIOR LATH OR DRYWALL 0 FINAL ELECTRICAL I EXTEMPORARY SERVICE \CJELECTRIC UNDERGROUND CD ROUGH ELECTRIC CD POOL BONDING JTRIC SERVICE ilLING HEAT G.F.I. SMOKE DETECTOR LD FINAL PLUMBING n UNDERGROUND PLUMBIN CH UNDERGROUND WATER CD ROUGH PLUMBING CD TOP OUT PLUMBING CD SEWER AND PL/CO d TUB OR SHOWER PAN CD GAS TEST D WATER HEATER CD FINAL MISCELLANEOUS CD PLENUM AND DUCTS LD COMBUSTION AIR CD PATIO a SIGN CD GRADING d DRIVEWAY a CONDITIONED AIR SYSTEMS a REFER PIPING CD FINAL READY FOR INSPECTION: a MONDAY D TUESDAY DA.M. DP.M. D FRIDAY SPECIAL INSTRUCTIONS. REQUESTED BY_.PHONE NO.. PERSON TAKING REPORT. .REQUEST FOR INSPECTION INSPECTOR AJ^f*' PERMIT NO.. OWN E R_; TIME:. 30- ADDRESS. BUILDING d FOUNDATION d REINFORCING STEEL CD MASONRY Q GROUT-GUNITE d FLOOR AND CEILIN d SHEATHING CD FRAME C] EXTERIOR LAT Q INSULATION CD INTERIOR LATfl OR DR1 a FINAL ELECTRICAL CD TEMPORARY SERVICE CH H.ECTRIC UNDERGROUND CH^OUGH ELECTRIC POOL BONDING ELECTRIC SERVICE CEILING HEAT D G.F.I. C3 SMOKE DETECTOR CD FINAL PLUMBING CD UNDERGROUND PLUMBING CZI UNDERGROUND WATER CH ROUGH PLUMBING CD TOP OUT PLUMBING CD SEWER AND PL/CO CD TUB OR SHOWER PAN CD GAS TEST CD WATER HEATER CD FINAL READY FOR INSPECTIO SPECIAL INSTRUCTIONS MISCELLANEOUS PLENUM AND DUCTS CD COMBUSTION AIR CD>ATIO SIGN GRADING CD DRIVEWAY CD CONDITIONED AIR SYSTEMS CD REFER PIPING CD FINAL D WEDNESDAY a THURSDAY Q FRIDAY REQUESTED BY .PHONE NO.. PERSON TAKING REPORT. INSPECTOR OWNER INSPECTION PERMIT NO. TIME:. d FOUNDATION d REINFORCING STEEL d MASONRY d GROUT-GUNITE ^LOOR AND CEIL SHEATHING d FRAME d EXTERIOR LATH d INSULATION d INTERIOR LATH OR DRYWA d FINAL CD TEMPORARY SERVICE CD ELECTRIC UNDERGROUND d ROUGH ELECTRIC d POOL BONDING TRIC SERVICE CEILING HEAT D G.F.I. SMOKE DETECTOR d FINAL PLUMBING d UNDERGROUND PLUMBING d UNDERGROUND WATER d ROUGH PLUMBING d TOP OUT PLUMBING d SEWER AND PL/CO d TUB OR SHOWER PAN Q GAS TEST CJ WATER HEATER d FINAL MISCELLANEOUS D PLENUM AND DUCTS a COMBUSTION AIR a PATIO d SIGN D GRADING Q DRIVEWAY D CONDITIONED AIR SYSTEMS !ZI REFER PIPING d FINAL READY FOR INSPECTION:D MONDAY a A.M.^—'.M. D TUESDAY DTHURSDAY D FRIDAY SPECIAL INSTRUCTIONS. REQUESTED BY Qv Q.PHONE NO.. PERSON TAKING REPORT. REQUEST FOR INSPECTION TIMF- INSPECTOR OWNER d MASONRY CD GROUT-GUNITE CD FLOOR AND CEILING FRAME d SHEATHING CD FRAME d EXTERIOR LATH d INSULATION Q INTERIOR LATH OR CD FINAL CH TEMPORARY SERVICE CD ELECTRIC UNDERGROUND ROyGH ELECTRIC OOL BONDING ELECTRIC SERVICE CEILING HEAT G.F.I. SMOKE DETECTOR FINAL PLUMBING Q UNDERGROUND PLUMBING CD UNDERGROUND WATER O ROUGH PLUMBING a TOP OUT PLUMBMQG CD SEWER AND PJ^CO CD TUB OR SHOWIER PAN O GAS TEST ED WATER HE A CD FINAL LLANEOUS PLENUM/AND DUCTS CD COMBUSTION AIR CD PA1 Cl*fGN GRADING CD DRIVEWAY CONDITIONED AIR SYSTEMS CD REFER PIPING CD FINAL READY FOR INSPECTION: D MONDAY XLA.M. DP.M. 0- ^ 7SPECIAL INSTRUCTIONS r ~\ (^THURSDAY JD FRIDAY REQUESTED BY PERSON TAKING REPORT REQUEST FOp INSPECTION 'lWfr~' OWNER a a a Cl CI FOUNDATflBN REINFORCING STEEL MASONRY GROUT-GUNITE FLOOR AND CEILING FRAME SHEATHING FRAME EXTERIOR LATH INSULATION INTERIOR LATH OR DRYW; FINAL PLUMBING d UNDERGROUND PLUMBINCT tn UNDERGROUND WATER d ROUGH PLUMBING Cl TOP OUT PLUMBING CJ SEWER AND PL/CO Cl TUB OR SHOWER PAN CJ GAS TEST CJ WATER HEATER D FINAL RARY SERVICE ECTR1C UNDERGROUND ELECTRIC ^OIROOL BONDING OELECTRIC SERVICE CEILING HEAT G.F.I. SMOKE DETECTOR FINAL MISELLANEOUS a PLENUM AND DUCTS COMBUSTION AIR a PATIO a SIGN a GRADING D DRIVEWAY a CONDITIONED AIR SYSTEMS CD REFER PIPING a FINAL READY FOR INSPECTION: OMONDAY Q TUESDAY/ a WEDNESDAY \DTHURSDAY a FRIDAY DA.M. ap.r SPECIAL INSTRUCTIONS REQUESTED PERSON TAKING REPORT, REQUEST INSPECTOR OWNER_L_ NSPECTJON PERMIT NO. TIME:— J- DATE: ' / ADDRESS."JL BUILDING CD FOUNDATION n REINFORCING STEEL d MASONRY d GROUT-GUNITE C] FLOOR AND CEILING FRAME CD SHEATHING Cl FRAME D EXTERIOR LATH Cl INSULATION CD INTERIOR LATH OR DRYWALL a FINAL ELECTRICAL C] TEMPORARY SERVICE O ELECTRIC UNDERGROUND d ROUGH ELECTRIC CD POOL BONDING d ELECTRIC SERVICE D CEILING HEAT D G.F.I. a SMOKE DETECTOR 0 FINAL PLUMBINGJ UNDERGROUND PLUMBING UNDERGROUND WATER sJOP OUT PLUMBING d SEWER AND PL/CO d TUB OR SHOWER PAN CD GAS TEST a WATER HEATER CD FINAL fa MISCELLANEOUS CD PLENUM AND DUCTS O COMBUSTION AIR a PATIO n SIGN CI GRADING CH DRIVEWAY D CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL READY FOR INSPECTION: D MONDAY D TUESDAY DWEDNESDA Q A.M. DP.M. DTHURSDAY Jn FRIDAY SPECIAL INSTRUCTIONS. REQUESTED BY. 7 .PHONE NO.. PERSON TAKING REPORT. RECEIVED DATE: DEC ?1 1979 INTERDEPARTMENTAL INFORMATION ING DEPARTMENT UILDING ADDRESS: Building Department PLANNING DEPARTMENT ALLOWED LOT SIZE LOT WIDTH UNITS PROVIDED PARKING SPACES REQUIRED % COVERAGE ALLOWED HEIGHT ALLOWED SRI BACK; _PROVIDED_ _PROVIDED PROVIDED SIDE SETBACK: ALLOWED PROVIDED INTRUSIONS LANDSCAPE & IRRIGATION PLAN COMMENTS: REAR SETBACK ENVIRONMENTAL PROTECTION REQ: DISTRICT:.AMOUNT:, ADDITIONAL COMMENTS: A-L. OK TO ISSUE:OK TO FINAL f DATE ENGINEERING DEPARTMENT R . 0 . W .INDUSTRIAL WASTE -CONNECTION GRADING PERMIT DRIVEWAY LOCATIONS EASEMENTS DRAINAGE LEGAL DESCRIPTION ADDITIONAL COMMENTS OK TO IS*SUE:DATE H FWI OK TO FINAL A$ti/ DATE FIRE DEPARTMENT SPRINKLING SYSTEM FIRE ALARMS FIRE HYDRANTS ADDITIONAL COMMENTS _FIRE PROTECTION EQUIP. EXITS LOCATION OK TO ISSUE:DATE QK TO FINAL DATE WATER DEPARTMENT REQUIREMENTS OF APPROPRIATE DISTRICTS MET DATE COLLINS DEVELOPMENT COMPANY 11750 Sorrento Valley Road • Suite 209 San Diego, California 92121 • (714) 276-3380 Contractor's License Number 214515 January 25, 1980 RECEIVED JAN2 71980 City of Carlsbad Building Department CITY OF CARLSBAD Building Department Re: Building "B11 T.H.K. Palomar 2245 Camino Vida Roble Carlsbad, CA Gentlemen: We are forwarding herewith structural calculations for the alternate tie strap connection at the tilt-up wall at the north side of Building "B" due to the fact that the purlin anchors were improperly located in the original tilt-up panels. Please retain these for your records. Very truly yours, John J. Kleeb Project Manager JJK:bw cc: Don Yerly Permit file ':,; j & /I. / T£ f T/t/» °r --^£2*. i. iII J? X K V" X 6 •4-*X M T )'/&"- - / -L.O ^ >c -L.O K ^ i v. f .^ 3 y iv y >c (n f 2, <}> / rJ C- , ft t> t- T 30 Kf-' x /\ IAJ/) H- 4"* COLLINS DEV. CO. it? _ ,.--*••> 4 < T , -7 0^4 x: 6 s T-H< /I fJC... t '» / /t = 6 o , /f iAJ/1 t I*, o T *tv' IJ X VM-^ '/«" ) v' [ >- U*J L i 7 /5 c--n -vW. — f>ir;c/\ Li??xn 4- i. 0 (Ji ->vj t/ "^ - / [-30 x x. > U. * 3 ) X 1C. ^ T *t COLLINS DEV. CO. ti WOODSIDE/KUBOTA & ASSOCIATES, BNC. 2465 Pio Pico Drive . P.O. Box 1095 • Carlsbad, California 92008 • (714) 729-1194 MjQ f? 7 /* In/-,"™ 1 ^ /^gQ March 13, 1980 Mr. Ray Green, Bui 1di ng Department City of Carlsbad 1200 Elm Avenue Carlsbad, CA 92008 Subject: Lot 12, Parcel A -- Palomar Airport Business Park -- Unit No. 1 Costa Real Municipal Water District Dear Mr. Green: The Costa Real Municipal Water District has approved the public water system for the following units of the subject development. Building "A" -- 2225 Camino Vida Roble Building "B" -- 2245 Camino Vida Roble Building "C" -- 2265 Camino Vida Roble Attached is a plat map showing in red the three (3) units that are involved with this approval so that you can per- mit occupancy. If you have any questions, please contact F. Jerry VJhitley or the undersigned. Very truly yours, & 7JclcIO/. Kubota, District Engineer Costa Real Municipal Water District End osure cc: Costa Real Municipal Water District Paul Thomas, THN Palomar Alex Wolencnuk, Fire Marshall, City of Carlsbad FJWtpaf In Orange County, Sanla Ana CMWD 79-204 JAIK CHOI & ASSOCIATES Structural Engineering 3822 Campus Drive, suite 120 Newport Beach, California 92660 December 7, 1979 Mr. Rix Reinecke, AIA Building Concepts Inc. 3978 Sorrento Valley Blvd. San Diego, Calif. 92121 Re; T.H.N. Polomar Offices Building Dear Rix; This letter is in reference to the mechanical units on roof of the above referenced project. The mechanical units weigh 1,925 Lb. each and are to be directly lo- cated on each cloumn location. Therefore it does not create any additional flexural stresses to the glu-lam beams. However, it induces more load to the footing which is critical at columns on grid line "B" of the Building "B". The total load including mechanical unit is 39.3 kips (37.3k + 2k) and the capacity of 3'-6" square footing is 40.4kips(3.5 x 3.5 x 3.3ksf) which is larger than 39.3 kips. Therefore existing footings are adequate for the additional load from mechanical units. Should you have any questions regarding this matter, please call me at your convenience. OC/dt BURROWS CONSTRUCTION COMPANY, INC. 164-B WEST MISSION AVENUE - ESCONDIDO. CA 92Q25 - UCENSE NO. 348601 - PHONE 745-8665 December 6, 1979 Projectt Bldg. B Oak Systems Location i Palomar Airport Business Park 2265 Camlno Vida Roble Carlsbad, California Material List of Approx. Storage Electronic components such as capacitors, resistors, transistors, I.G.'s, metal parts such as screws, nuts, chassis, eyelets, etc. The majority of the components in stock will be capacitors and resistors. The approximate quantity of stock will be as follows i Capacitors 5,000,000 Resistors 10,000,000 Transistors 3,000,000 Chassis 30,000 Hardware 10,000 Each . (Screws, Nuts, Eyelets, Etc.) Solder 1,000 Lbs. Cartons 4,000 '***^ ows Construction Company, Inc. U. L-\ 4- J, 52 J , 2.4:1 7, I :.s6-t i A ro , A RR- S7 ,4-2, water-saver toilets, for flush valve i his toil^nivesvouqiiio; flush;action, as well as off-the flortr sstaliation [v/h-ch means easier cleaning, improved sanitation) Water-Saver Afwall toilet I'477.016 (less seat) Water-Saver Afwal! toilet—siphon jet action— elongated bowl—off the floor—1)2" top spud — ,'ilreous china. Cnrrifr and drainage fitting by others. Suggested flush valves for writer saving for above toilet. Deiany Flushboy 402-35VB Sloan Royal 110-3 •:ole: Minimum working pressure—15 psi at vaive. while flushing nominal dimensions a-13" (330mm) b-5ii"( 133mm) c-25X"(654mrnl d-18!i" (470mm) e-14" (356mm) I—2" (51mm} water surtaca—10K" x 13V (273mm x 340mm) seal—3" (76mm; ball pass-2X" (57mm) —2^" ;64mm) This toilet givi-r.-; you qtiiot flush action, as well as off-the-floor ins'dl^.i'On (which m-r-ins easier c!a:mintj, irriprovocJ r.ani'rjtion) and water savinn. Water-Saver Afwall toilet 2478.014 (less seat) Water-Saver Afwall toilet -siphon jet action—elongated bowl- off the floor—114" back spud—vitreous china. Carrier arrj drainage fitting by others. Suggested flush valves for water saving for aboye toilet. Dclany Fius'nboy Sloan Royal Note. Mm;mum v.orking pressure —15 psi iit valve, wfii'e flushing. nominal dimensions a-13" (330mm) b—S'A'i 133mm) C-25K" (654mm) d —18:4" (470rnm) e--14"{35Smm) t~2"(51rnm) watec surf3ca-10^" x (273mm x 340mm) seal—3" (76mm) bali pass—2X" (57mm) passageway—2#* (64mm) 3-14 (6/79) D Flush Valves ROYAL 110 COOS N'JMaEfl O Qu'st txpjsed Ciosst Flush Valve, Chrcmy Pl-Jted. metal oscillating non-hold-o;.;i.'i handle, 1-inch I.P.S scrow driver Bav; -Che^, angle jtcp wish pio-active ca;j. adjustable tai!p'e_e, vacuurn b^-^kvr liush connection anJ spud coupling l.jf T/'-inch \op spud, vs.il! and spud llangss. ORDERING PROCEDURE 3 Name of valve — Royal, Crown or Naval. D Installation number-110 C Letters designating variations, if any. (Extend PAGE 127 for reference to variations). Example — Royat 110YB Cl Convert to Code Number using table below: To order Royal Flush Valves Insert 1 in box ; i'. To order Crown Flush Valves Insert 2 in hux ~2_. To cider Navs! Flush Valves Insert 4 in box '4. Code number for Royal 11QYB is 3010111 Installation No. 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 Variations YA YG YO YB YBYA YBYG YDYO YDHL-3 YBHL-3YO YC YCYA YCYG YCYO HL-3 HL-3YO Code Number aonojoo SOT"! 0105 30:"' 0107 30 H 01C9 30 - j 01 1 1 30 f~j 0112 30 _~j 0113 30 l_] 01 1 5 30 i~;0!20 30 -~j 01 21 30 G 0123 30 r] 01 24 30 ; 10125 30 i ] 0127 30 CJ 0130 30 TJ 01 31 SLOAN VALVE COMPANY • FRANKLIN PARK, ILLINOIS 25 urinals vitreoi js china Wasbbrook urinal (fixture only) 6500.01 I top spud (illustrated) 6505.010 back spud VVashbrook vitreous china washout urinal—%" inlet spue!—outlet connection threaded 2'' inside- wall hangers. Suggested flush valves for Washbrook: DelanyFlushboy [6500.011)451 VB; (6505.010) 571 VBS. Sloan Royal (5600.011) 186-11; (6505.010) 195-11. Note: Mtrvmum working pressure—15 psi a! valve v-vhile flushing. See pago 1-30 (or high Sank for use with Wjshbrook Urinal. nominal dimensions Lip height— 24" (610mm) optional a — 18" (457mm) b- 11 VI 296mm) d-21" (533mm) Lynbrook urinal (fixture only) 6530.018 top spud (illustrated) 6535.033 back spud Lynbrook vitreous china blowout urinal—wall hanger- 1 YA" inlet spud -outlet connection threaded 2" inside—privacy shields. for use with flush valve only. Suagsstcd flush valves for Lynbrook: DeFany Flushboy (6530.018) 452 VB; (6535.033) 572 VBW. Sloan Royal (6530.018) 180. (6535.033) 190. "7 _jijiI ll ^ ^\^ri/ u . — - a— — rTv'g • ^ r-n Mfn. nominal dimensi . . i, • u* 0*>r ,cLliJ TOtflnt — ^4 (n ;!•?: optional "li a-18* (457mm) -J j{ ^. b--12K"(324mm) >.iL c-43"( 1092mm) 1;".:^^v:/ 1_b-4d finished waft —i, I \.... d-2»" (533mm) 3-26 •:>>-*;^.. *.:^.^£^±JL»^ ••pg^ff i L__ 1 L•-D F^- On * J LZ1 :*J*^" **"* ". ^:^^^s^^^^&^^^S ^••^=^^^^r^^^fe«^r;^^ql^-r^—•—s~l ^=sges^^:L^»^>>>"-4^3 M -I I a 1 • •'jJa^'5^j-\:-"!-''-^v^g-^*3S'>K .A.-T-Ji^SJ 4 • S3 ^»€^»^^"T>«v<v«-*.-v^M2<\l3,"'«>'^r • ^ ^ -_. T -—. .^.mif^^^ "^ ^<*-'_ iT.cr-A.^i'i* i *>* . I— c±H NU.V.ScR \ Flush Valves ( . / (Fo; u.s wilh Urinals requiring a flushing cycle of 20 secc,i:'li minimum}. Quiet Exposed Urinai Flash Valve, Chroma P'ateU, metal oscillating non-hold-cp-n handia, %-ir.ch I.P.3. screw driver Bak-Chek angle slop vvitn protective cap, adjust- able tailo'ece, vacuum Lfsakar flush connection and spud co'-pliiig (or Vi-inch top spud, wall and spud flanges. NOTE' For Aulomnlic Rushing see pages 76-73- ORDERING PROCEDURE 3 Name of valve-Royal, Crown or Naval. fa Installation number-186-11. C Letters designating variations, if any. (Extend PAGE 127 (or reference to variations). Example-Royal 186-11YB U Convert to Code Number using table below: To order Royal Flush Valves Insert 1 in box 1 . To order Cro.vn Flush Valves Insert 2 in box 2;. To order Navo! Flush Valves Insert 4 in box 4^. Example-Code number for Royal 186-11YB is 3012711 C Installation No. 185-11 166-11 186-11 186-11 186-11 186-11 185-11 186-11 185-11 Variations YB YBH Y8HL YDHL-3 YC H HL HL-3 Code Number 30 " J 27CO 30 ..2711 30 " ; ; 2716 30 2719 30 I 2720 30 " ! 2723 30 i J 2728 30 " "; 2729 30 J 2730 ( SLOAN VALVE COMPANY FRANKLIN PARK, ILLINOIS 58 wall hung lavatories This durable lavatory comes tn thre (tho narmvvc'-.t is a mere 13" [3 ; in nut one just ;Oout an>v. H.jnM<;o pop up 'jvjlory faucet >r,ps 2 J'JJ 1 L>4 Ledgemere lavatory {fixture with fittings) 5300.033 13" x 13" (330mm x 330mm) 5300.124 1G"x 14"(4C6mmx356mm) 5300.215 18" x 15" (457mm x 381mm) Ledgemere lavatory with factory mounted Heritage faucet with lever handles—pop-up drain- wall hanger-—acid-resisting enameled cast iron- soap depression. nominal dimensions a b c d bowi sizes widih (root to back depth 13"x13" 13" (330mm) 13"(330mm) 3%"(92mm) 3" (76mm) 13" x13" 10"(254mm) Bl/i"(216mm) 5" (127mm) 16"x14" • 16" (406mm} 14"{35Grrm) 4" (102mm) 3" (/umm) 16"x14i( 12T (324mm) 8;i"(222mmJ 6"(ib3mm) 18'x15" 18" (457mm) 15"(381mm) 4" (102mm) 3" (76mm) 18" x 15" 14#'(3S3mm) 9^i" (248mm) G" ( 1 53mm) ; t.-i.".cs n variety n n'j-:><] for,: siv.-.-r-touqh :,:v;i!ory. 014 Regalyn lavatory (fixture only) 4369.012 4" (102mm) centers 19" x 1 r (433mm x 432mm) fillusfratad) 4869.020 4" (102mm) centers 20" x 18" (508mm x 457mm) 4867.016 0" (204mm) centers 19" x 17" (483rnm x 432mm) 4867.024 8" (204mm) centers ?0" x 18" (503mm x 457mm) Regalyn lavatory--wall hanger—enameled cast iron- soap depression. nominal dimensions a b c d 19" X 17" 19" (4S3mm) 17" (432mm) 3/i" (83mm) 4" (102mm) 20-JE18" 20" (503mm) 18" (457mm) W (92mm) 4" (102mm) bow) sizes width front to back depth 14//(368mm) 87»" (222mm) 6"(1&3mm) 151/!"(394fnm) 9/'a"( 249mm) 6" (153mm) ^AMERICAN ^STANDARD 2-19 service sinks Akron service sink 24" x 20" (610mm x 508mm) (fixture only) 7635.018 v/rlh 8379.026 run guard Cnameled cast iron service sink--wall hanger— for through-back faucet—drain channels in bottom. nominal dimensions compartment size width —iy,V i505rr.m) front to back —163J" (416.nm) depth—10'-;-" Akron service sink 24" x 20" 1610mm x 503mm) 7696.016 with 8379.026 rim guard Enameled cast iron service sink—wall hanger- piain back -drain channels in bottom. nominal dimensions a—24"(6iumm; c-9" (229mm) d—26>." (667mm) compartment s'rza width-19JV' (505mm! front to back—IStf* (416mm) !n;-4" (267mm] AMERICAN STANDARD 4-21 Wall Mounted Fountain CABINET NV.nuKictured -">f hrnvy yau^;,' M..-£-?!, n"iK'>d c:i ennniet colors providn a snuxirh. unbrc'-.un, p'OteUive c.o^Iiii-j ever the entire rti!)tr-'t. HuSi'jMnt lov.rM!. rr.oisture. perspiration, h>-,it fin:f sunlight. Also available instJn'ess steel a.\l vinyl-ck-id i,!et>! COOLER TOP Anil-splash riricj-j reduces splatter Connur cos'J.T cnautes pfo^^r drainage ar.J prevents ;.:arr.i:ng ',v3r>te waler StLtinieis steel lop ^vith t,a:m dn.sh tO3is'3 stjins and corros'on an.'i i:, t;3r>y *n mainSain. PROJECTOR H":ioey Taylor exclusive 2-strearn moun1:! build- ing projector with ncn-re.'nobble an!:-^qjiri (oa'uro iriMi.'es a fas'er, moro comfrrtaWe and :.^:i:'/yin9 drink ci water. One piece chrome p!;il'Vl unit has integral hood guard design Ic P^vv-.'nt contariiinut.on from olher ns^rs and ii.r b.irnp deposits. AUrOMAFIC STHEAM HEIGHT REGULATOR 1h:ssiilf<losing nb'iombly is located ins.de cribin-''t toprc^ont tampering Heavy duly ccr- rn-ion-fosi'jtant construction Phoiphoro-js Li.-u.ize cperatiny spnr/js. 2nd rugqxJ rubber di,-!phr;-p'ii. !n nrliJition. large tree-flowing ontic'.is in the roctuljtor valve resist dc-riosits and pr'.'-.'onl ciogginy Acons-tant stream height i;- .luloina'. c..:l!y nviinr.'iinod UMJOI line p.'j;,- Gurt;s that vary from ?0 to 90 pci. EVAPORATOR/CHILLER WATER Ll;',:qiie dt'3;yn concept combines countertio'.v CciC'ling wiih otfs-iv.-nE bonding of the refngor- fint anj Wdlcr coila for rndxuriLim he.lt transfer PRE-COOLER If.C'Oased offi'_iij:'iLV' rousts C'ipjcily Double -A?!! construct! in h:ib jriirorKif1 tine ceiled aronnd nrvi be. -Jed t^cc- dr?.M line 1" (ciL'p'ox ' froe-fic'.v jrea ou! drain line reduces chance of clng Special non-limcig bjffle easily .'cn-io co.Tiplete access a^J ^le^ning to c!'3: TFMPERATUHE CONTROL Pc?;:r.w Lertsir.g ifiern'.Cbt-it for contr tJf'pcraturc1 of ev.ipcr".;;",' rh'lV" 'in v-Ti'-v It is factory bet Lit !jO F A;iJList -i 5° F. FAN MOTOR lin;! bearing self lubricating type for r nnce free longer hie STRUCTURAL SIDE MEMBERS Rugged structural ?ici^ rne-nbers pf "^ rrii.'i, sJ'ony fiarr.'j that allov.-s easy r nf a!i panels for rr: i/imurn fjorvtctTibi optional finish chang-s CONDENSER Copper/aluminum coriStruction w:th air flow Molded shroud pre^on'.s v.^r caused by h:gh humidity conditions INSULATION SYSTEM fi'vaporatnr/chilier Cirploys totally ei. ta!ed one p)C:ce construction of high EPS for maximum inyjiatir.g chaiaGi REFRIGERATION SYSTEM System balance, lov.er energy usage loc.g'jr life assured by udhzmg hiyh d ; a vril and UNIT IVIODELS WM8A-1 WM14A-1 WM16A-1 VVM20A-1 Finishes ami Accessories {See reverse sida) finish is :;rny bi-ked emme!. nient comoressof. GOLinter-flow cooling evar> orator/chiiler. elhcient capillary sizing, large capacity tiryer-&!r=;jn€:r. fan-cooled condenser v.'uh rnax.rr-um heat exchan:-,-? and venturi air fio.v (wa'.er-cooiod mct.ic'5 r.:so available) Hermetically sealed, posilsve start cortiprfS- sor w:th lifetime lubrication dnd built-in over- 102C1 protection. System completely sealed after dtup evacuation, dehydration and pres- sure testing f5 235 psig Protected by Haisey Taylor 5 Year Warranty p! jj additional 5 year material v;:i;raoty on evaporation/chsiier. TS SUGGESTED SPECIFICATIONS ShaH deliver ( >G.KH cf 5CP wafer at 90D ambient and 80° inlet w^ter. Top shall be stainless steel with removable drain strainer. TYect'Olor battle shall be re--r;ovab!e for niaxi- mum access to drain interior Prcjector shall be hV'D-s'ream. mound-building type. Separate valve an<! diaphragm automatic stream regulator shall h-e mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor, non-pressurized counter-flow cooling cot! with totally encapsulated EPS insu- lation and to be controlled by positive sensing thermostat. Cabinet shall utilize rigid interior fr;irr;& concept lo permit easy removal of exterior panels. Shall be certified by AR! to muvl Standard 1010-70 Coo!** shall be Halsey Taylor Model ( }. and HALSFYTAYLOH DIVISION - KING StrELEY K5T THERMOS CO ROUTE 1^. FREtPORT. ILLINOIS 61032 VV.'ill Mounted (-onntoin 1'..'. MINI:; M INSTALLATION .MOUNTING INSTRUCTIONS Mcuri; trap ^ip.d h^fijor bracket and i.is'aJ! uM'ir. c.onr,.'x;tiGn.'ii?r.'i'e ?top to tu,: jt^cj supply lino. To insuf s proper ena iQinq of v-dhlc! l,rv into trap, conier line ol trap n-iibl be 6:i" Iron: '.vail ft:ce. (See nld!-'; ?). 2mJ install on wasle li^d tube Hang croler on bracket and enqage w-s.stti hn^ tube in^o trap inlr?i Center Line heignt of waste ouMet •• = 2?'..'" from Itoor line (or conventional PLUMBING CONNECTIONS Kn;<" r!:n>cl!y ink) cabinet Wjstfi 1'." O D. ri.p'-nur.pction Supply '-»' IPS ELECTRICAL Furnis^rx.1 with p!i:y-t;i. 3-wire groiird,ng IVP-; :-"-rv.^o corrj St.ind-ifJ 12C)voU. a'1 ['!.ip;L' f^r olher D r.-.^r supply's (Soe r."pricey char! [or a:~:p ntirxj). \:^'.-'M 120-voK rou.'pMcle. ia!od at 15-Jr"p;) niifiimum, to "vjeive 3-v.'TG p,':i,uiel b!:4/Je groun,::n!j type mile pUsy Finishes and Accessories Standard finish is gray baked enam Optional U Mocha Brown Vinyl LI Silver Spice Vinyl G Polychrome Colors— — (speoly color] DAII Stainless Steel (extra cost) Optional Accessories (extra cost) UvU'iter filter lass filler - ARCHITECT/ENGINEER APPROVAL •Reference at recommended 40" adult mounting height WM-AIR-COOLED Mode! No. VVM-8-A-1 WM-14-A-1 WM-16-A-1 WM-20-A-1 (A) SERIES GPH Capacity Cooled to 50° Ambient 70° 9.6 1G.S 19.2 23.0 R* Air Temp. 80 8 15 17 21. - 8 4 ,6 4 90° 8.0 14.0 IG.O 20.0 Base Rate Cap. Motor HP. F.L Amps Shipping Weight 100° 7, 12 14 17 .2 .6 4 6 5.0 8.0 9.5 12.0 1/6 1/5 1/4 1/3 3.4 5.5 5.7 8.3 77 Ibs. 80 Ibs. 86 Ibs. 87 Ibs. 'With projector service (pre-cooler) and tap water at 80° F. UL listed and certified by AR! to meet Standard 1010-73 c HALSPY TAYLOR DIVISION • KiNG-SEfitEY KST THEF^.'OSCO ROUTED FRFEPORT. ILLINOIS 61032 FUNCTION: Gtnvtd S'.-i.-; •.-.V:r..» foul traffic is expectx). >"• -.• - r~-|.!,!fc' top is p.Tiicularly adaptable n :' S-j!txiton of additional strainer ht-nc.'!. i > >!r;iin lor use in :;!;i:'/,.:t;, ;_!•?«, V.iti.'i-jns, and othrii- finish**! areas •c;i strainer hta-J i; i1 •-.'• :'~<r T.I types of poured finished Moore. The '• it n.-s finished of ;Tia;,ri; in ujuara or straight Itni? patterns, specific design r-jqL-'--'1"1'?'1'"' • ''£ shown un p^oes 78 and 70. REGULARLY FURNJSHEO: Duco Cast Iron Body jnd * Flashing Cellar with Protector Cap and Nicxel Bronia Adjustable Strainer Hi'*J with S(K:ured Square Holu Grolt?. Type of Strainer He«d ns lndica;?d by Suffix Letter Set*rted. LOW POSITION XX -WIN. OD'a. - or Sq.^v-z? IPOSi>l GH ITION VARIATIONS: Sediment Bucket (3) Hinged Grate {Hi Heel-Proof Grate r/i"Squaro Holes) (HP} Trap Primer Conn. (P) Vandal Proof Grain (U) Fljpper Typa BacVwaiw Vaiv» Round Tiit-Top Strainer Head (V) X -M!N. MAX.Recommend **i Outlrt Size Siz» OPTIONAL MATERIALS: Galvanized Body tG) Bronze Body Polished BronzaStrainwr Chrome Plated Gtrgintr Fig. 2010-A me«t$Gov't Spec. WV-P-54Ib, Typ« 2t5 as listsd below Out!»t Chrom* Plated Strain e* ft ead__ 6 Dti. 8 Dia. 10 Dia. Fig. 2010-A ..... ROUND TOP Fig. 2010-B ..... SQUARE TOP A-l.P3.-2. 3c»1INSIDE CAULK OUTLET nThfwtiiwJ W-m 5p*c<rmd Relw 10 ("'.1311 73 anci '/:) fo( Opl.un.il Strninpr He*d» STRAINSR SIZE e dia. or sip. 5 6 7 ft 9 10 COLLAR IN HIGH -EQSmQCL X min. max. 1% Jit l'/4 IV, ISr,i 2W 2V. 2V. 7V: 2". 2 ^i COLLAR liM LOW POSITION X min. % U *ii % I X max. l4«i l^S 1% 17. 2^ 1>4 ! 2 l,i FREE AREA SO. i,N, .ounJ 6.0 10.4 14.1 15.7 — O 12.3 16.3 27.6 IS.U I 2^.5 34/4 ( 35. B c 2 PIECE BODY design eliminates need for separata flashing device THREADED COLLAR designed to receive all variations of SMITH strainer heads .EVERSIBLE FLASHING COLLAR •ouides positive clamp f waterproofing membrane SEEPAGE OPENINGS permit seepagfl into drain body CAULK OUTLET regularly furnished. Threaded when specified PROTECTOR CAP is regularly furnished to protect threads ami keep debris out of drainage system during construction REVERSIBLE COLLAR provides extra vertical adjuswnem for strainer TURf^STYLE SLOTS peiTiits easy assembly of collar without removal of non-corrosiv*bolts AUXILIARY INLET PAD tapped for trep primer connection when specified CAULK SUPPORTSTHAP Fig. 9329 supports drain body during caulk ing operation. Adjustable strap fits 2", 3" and 4" extra heavy and swvica weight soil pips Furnished FREE with ALL 2", 3" and 4" drains upon request Collar can be used as flashing device when required FEATURES FIG. 2O1O NOTE: All Strainer Sh«nki H»»«3K'M2 Thread 76 FREE caulk support strap available - 2, 3. 4" sizes (Fig. 9329) Refer to pa.qe 193. GVa" AND OVa" TOP - MEDIUM DEPTH RECEPTORS FUNCTION: fleromrniendsd for USH in roof crajs :o r^cci-'-j v%ji:a wa^er from air co.'iJttioninq ;.ii~i, cool- ing towers and o'.'ret ne<:hanical equipment installed on thj ro;jf. Tha sclid water dum pnv^t:; storm wa;£>r enter- ing I!IB w;n'(> lino. Thai trfje vandal proof dom» battomstMin:' fnvides jmpl? drair.Tya and '*' ••v^nts entry of dabris. REGULARLY FURNISHED: Oucu CJJT Iron Rfcoptor with Solid VVarw Dam Collar and Cast Iron Dom» Bottom Strainw Secured with Stainless Steet Vdndal Proof Screw*. VARIATIONS: Undardeck C!amp (C) Roof Sump Receiver (R) OPTIONAL MATERIALS: AM Galvanized (G) COMBINED NONJ'UNCTLiaiNG. FLASHING FUNG ANOSOLID WATEH DAM -I UNaCRDECKCLAM* WHEN SPECIFIED INSIDE CAULK OUTLET HSGULAW Fig.3960._6W"TOP -MEDIUM DEPTH Fig. 3970..-9'/4" TOP - MEDIUM DEPTH Fig. 3965...61/," TOP - MEDIUM DEPTH Fig. 3975...9Vi" TOP - MEDIUM DEPTH ~~3950~ ~3U70~ Sin 12 Recommended Deck Openings Fig. 3960, 3065 - '/'/." DIA. Fig. 3970.3975 - 11" DIA. Fiq. 3D65 3975 A-tPS 2 3 4 i 3 4 B (>% blA C ST s-4 F 4Vi 4l/i F f.1/: 7 G 3% 3 '.4 6Vs 8 '/i 4(ri 7'/j 3 Hi y v i 9/i V'.-i 12 12 12 4J1 4^i 4!'', 7 7 '/ia 4V. 4V. 4% 12 Va* TOP - MHDJUM AND DEEP RECEPTORS FUNCTION: Recomrrended for use in roof areas to receive waste waler from air conditioning units, cool- ing tow«rs and other mechanical frquinmant installed on the roof. The solid water dam prf-v?nt$ STQTTI water enter- ing tha waste lina. The large vandal proof dome bottom strainer provides ample drainage and prevents entry of debris. REGULARLY FURNISHED: DucoCast Iron Receptor with Solid Water Dam Collar and Cast Iron Dorm Bottom Strainer Secured with Stainless Steel Vandal Proof Screws. VARIATIONS: Underdeck Clamp (C) Roof Sump Receiver (R) OPTIONAL MATERIALS: All Galvanized (G) CAULK OUTLET REGULAR Tfifi»d*iJ W*«n Specified Fio. 3980...12'^"TOP - MEDIUM DEPTH Fia. 3090...12/." TOP - DEEP TYPE A-IPS 2^3,4, S, 6 2. X4, 5. 6 Fi». 3985...12'^" TOP - MEDIUM DEPTH Fig. 3995...12>i" TO? - DEEP TYPE Recommerided Deck Opening - 14%" DIA. ±'£t_ 3935 3995 A IPS E F E F r2 41/; 6V'; ! o :-. 12 '/i 3 4'/. 7 10^ 13 4 4M 7Vi I0*i 13H 5 4M Biipr~ 14 64Ji -Tuir Hrt f/?£"£" cju/tf support strap available • 2, 3, 4" sizes (Fig. 9329} Refer to paje 193.133 HORIZONTAL- FITTINGS SINGLE DOUBLE 39 ~—~~ ""1 I RI < —rY atoe 220* Shallower minimum roughen dirmnsJon, to accommodate lower rough bowls available.Fig.210-L . . .CAULK-LEFT HAND 1 Fig.210-LB , . .THREAD-LEFT HAND ! Fig.210-H .. .CAULK-RIGHT HAND Fig-210-HB.. THREAD-RIGHT HAND Fig.Z20-L . . .CAULK-L.H—LONG BARREL Fig.220-R . . .CAULK-R.H.-LONG BARREL Specify Fisj.21OD . . .CAULK Fig.21O-DB. ..THREAD Fig.220-O . . .CAULK-LONG BARREL For 5" size, specify prefix CV- Refer to page 15 A size 4 D min. max. % 3Vi ' J caulk thread 3* 1-% R caulk thread 16 ii vt Q dimension • 4" (regularly furnished) consisting of nipple and adjus-to-wall coupling permitting adjustment from 3" min. to 47A" max. Refer to page 13 VERTICAL. FITTINGS SINGLE Fig. 230-0 Fig. 230 Side View Fig.230 . . .CAULK F.g.230-B. . .THREAD Fig.260 . . .CAULK-LONG BARREL MIN SK MAX 9 Front View Shallower minimum rough-in dimension, to accommodate lower rough bowls available. Specify dimension required. Fi9.230-D . . JCAULK Fig.230-DB. ..THREAD Fig.260-D . . .CAULK-LONG BARREL Long barrel available in 4" size only For 6" size, specify prefix CV- Refer to page IS A size 4 5 D min. max. I'/i 4 '/i W 3Vi G caulk thread 8 6% 9 7% J y » L 3 J'.j M 7 7^i P rautk thread to B 11 9 S size ~sW T5~ dimension = 4" (regularly furnished) consisting of nipple and adjus-to-wall coupling permitting adjustment from 3" min. to 4'/i" nux. Refer to pags 13 For variations snd additional data. Refer to p^3« 3 thru 17 * Always specify fixture mfrs. n*ime and number when ordering. The Ceusible meets the stringent efficiency perfor- mance criteria for energy consuming appliances set forth by H.U.U. Standard for energy efficiency, A.S- HKAE Standard 90-75 and BOCO Corle. Check These Quality Features: CtnssDned lunks: tin; entire inner tank sarfare is lined with mi extra thick coating of vitrified ;.;li!ss. permanently bonded under intense heat (lfi(!y°F} lj insure maximum lank surface protection and years of rust iree upfr.ilion. Special E.C.O. {t'nerjjy Cut Off) Feature: a special UL listed, factory-installed heat-sensitive device cuts off ALL power to heater should internal tank tt-mpL-ra- ture re.'xh 190'K An'ide Rod: extruded magnesium rot! suspended in t<iiik lo proh'Tl ai4.:nist c<irrosi\e hot water action on l/tnk inner surface. Ifiyh effM'.i.'iif'y, thiiiaded cleinpnls: direct iir::ujrsion type. tbrea(i'.;d ln-'.'itint; elements drive a!! heat directly into the waicr fur maximum hfrilini; efin..ifncy. Prt:s sere sealed ^asVei pruvcnts leaking \V«I(!i:il Steel Ct)!i;»lin^s: no internal threads to cor- rode and (:<iut>i: ItMkini;. T. fi F. Valve Opening: b^parale %" NFT opening provided for installation of temperakire and Pressure Relief Valve (Maximum Hydrostatic Working Pres- sure 15U PSI) Triple-tested Tanks: pressure tested three times dur- ing manufacture' for highest quality assurance. New High Density MOU1KUM Insulation: lowest heat conductive douhle density insulation we've ever offeu'd. Saves fuel hecause of low standby loss (if heat. Set and Forjje! Thermostat Control: ;;-i automate cnntrol .setting to deliver a constant supply of hot water at desired teniperajuie. UL lisled: all nindels comply with Safety Spe- cifications outlined in Underwriters' Laboratories, Inc. Standards for Safely UL174. JacVuts are finished in a gloaming light yellow enamel with a contrasting dark jellow tri;n. The paint is eSectrc- tatically applie<l then baked. It is exceptionally durable and e.^y to wipe clean. 'Compl'-!e del.\iUi,f this warranty are avaihiblf at tin- nearest Stale sal-:"- uffii.e Residential Round Electric Watar Heater ., . Model . Numbep-^;-; PV-30-2RS7 PV-42-2RS7 PV-52-2HS7 PV-66-2RS7 PV-82-2RS7 PV-120-2RS7 ;Type .1.- of Unit. Double Double Double Double Double Double Capacity (gallons) 30 42 52 66 82 120 "Wattage (Max.) 240V AC (208V AC) 9000 12000 12000 12000 12000 12000 Recovery g.p.h. based on 240V Maximum 36.9 49.2 49.2 49.2 49.2 49.2 Dimensions (inches) Height 40Vz 50'/4 52V2 54 64 65 Diameter 20 20 22 24 24 23 Inlets Outlets (inches) V4 % % V4 % V4 Shipping Weight (pounds) 105 125 155 180 220 315 For models manufactured In Henderson, Nevada, add suffix H to model number. Example: PV-30-2RS7H. Maximum wattayes shown hero are available when specified. *{L)oubltj element wattages are based on ;;imuUaneous operation and must be specified — otherwise heater elements are wired to operate independently in an interlocking circuit.) All wattages must conform to local codes and utility requirements. Should maximum permissible wattages in your area be less than above, recovery con be determined at the rate of 4.1 g.p.h. per 1000 watts input. In keeping with our policy of continu- ous product improvement, we reserve the right to make minor changes with- out prior notice, INDUSTRIES, INC HEIGHT •DIAMETER- Ashland City. Tenn. 37015/Hendcrson. Nevada 89015 c c FORM STE 3/S-7B Printed in U.S.A. Residential Low Boy Electric • 20, 30. 40 and 50 Gallon St jrage Capacity 3000, 4500. 3000, 9000 and 12UOU M-.i/urum Wattage -,-. . 240/208 Volt. •-;. .:>:--q::--: -•':-^-^-- Five-year Li.Tiited Warranty': •' ''•''"^'i^'^>^-'-~:~~^'t&s':-'-' " - " " -?":---• ---• :.•; \^.:'^;'^\-:cr';LrsWherrusect.for commercial applicattonj'-. -.^- . •j-^.-^^vT"'—• — -~ - . "»... * *^- __ ^ -limited to one year.:";- Specialty designed far under connti.T ar;d crawl spar." installation ur where space is more limit than hot water needs. this Low Boy Electric Model has proven to be both a versatile and dependable source ot a family's hot water needs. Available in varyir.j-j tank capacities — single or double heating elements — 'I'iie Low Boy provides an abundant source of hot wutur for years of safe, economical. Iruubie- frct: operation. Check These Quality Features: th« entire inner t.mk surface is lined with rni evtra thick coating of vitrified jjljiss, pernia-iPiitiy Inindud under intense hi-Tit llb()0°l;) to insure ma\inmm t:mk suif:it:f proteclioti a:id y'-Mi' of rust-free operation. Sp*;ciul t.C.O. (Fnersy Cut Off) Feature: a special UL. listed, factory-installed he.it soiiMiive device culs uff ALL pcmvr f.o huater should internal tank tem- perature reach I:JU°F. Anntlr Rud: extruded magnesium rod suspended in tank to pruU;ct against corrosive hut \VdttT action on tank inntT surfricr Hi;;!i efficiency, thrc-'uled elements: direct immersion type, threaded In.Mtiu^ elements dri\i: all h>:at direct- ly into the water for maximum heating efficiency. 1'ressur,; sealed gaske! prevents leaking. \Veldttd StijL-l Cdtiplinys: no internal threads to cur- rode and cause !eakiii£. TM1 Valve Op«nin»: separdte %" NPT tip::niny pro- vided for iiiiitaiuitiiui of temperature and Pressure Hehef Valve. (Maxtiatsni llytlrnslallr Working Pres- surt: 150 I'SI) Triple-tested Tanks: pressure tested three times dur- ing manufacture for highest quality assurance. Fiberglass insulation: a thick, non-settling fiberglass blanket surrounds the tank to maximize heal reten- tion and Hfe-lon^ economy. Set nml Funnel Thermostat Control: an Hutornatie con- trol suiting to deliver a constant supply of hot water at desired temperature. UL lisliul "Approvinl": all models comply with Safety Specifications out lined in Underwriters' Laboratories. Inc. Standards for Safety UL174. Jackets an; finished in a gleaminj;. li^.ht b'u-* enamel with a contrasting dark blue trim. The p-iint is elec- trostatically applied, and baked. It is exceplior-ally dur.ib!'- and easy to wipe clean. *C"nmplete tli;tai!s of this w.iiTan'.y are .u'.ii'.arile at tlir: ni:.irf?sl St'ile s:i!es office. - -•. • ---•—• ^ -c.-vs«i^.- a>:^»;• ". - —~-• ^»<^-.''..- Residential Low Boy Electric t i -C. Model Number CV-201LS7 CV-30-1LS7 -*- CV-30-2LS7 CV-40-1 LS7 CV-40-2LS7 CV-50-1 LS7 CV-50-2LS7 Type of Unit Single Single Double Single Double Single Double Capacity (gals.) 20 30 30 40 40 50 50 Wattage (Max.) 240V AC (203V AC) 3000 4500 9000 6000 12000 6000 12000 Recovery g.p h. Based on 240V Maximum 12.3 18.5 36.9 24.6 49.2 24.6 49.2 Dimensions in Inches Height 31 '/4 31 31 31 % 31 tf 31/2 31K Diameter 16 20 20 24 24 26 26 lnlets& Outlets (inches) y* % M K 3/« K % Shipping Weight (pounds) 70 95 ICO 125 130 145 150 For models manufactured in Henderson. Nevada, udd suffix H to model number. Example: CV-20-1LS7H. Maximum wattages shown here are available when specified. Double element wattages are based on simul- taneous operation and must be specified — otherwise heater elements are wired to operate independently In an inter- locking circuit. All wattages must conform to local codes and utility requirements. Should maxi- mum permissible wattages in your area be less than above, recovery can be determined at the rate of 4.1 g.p.h. per 1000 watts input. In keeping with our policy of continuous product improvement we reserve the right to make minor changes without prior notice. ANODE ROD T&P VALVE OPENING , HEIC;HT — DiAMETEF 0 .a • CD Side T&P vatvs opening 26'/2" from bottom of tank on 20 gallon mode! only. INDUSTRIES. INC.Ashland City, Tenn. 37015/Henderson. Nevada 89015 FORM STE 9/7-70 Printed in U.S.A. /. I .. --y^/s.revt.'/ic-a'. "Ti^'T SF 'I"!!!;! =. B I.. £>_c, BUILDING DATA FORM BUILDING ENVELOPE COMPLIANCE Project TW. fcLHfl.fe • £>Ak:<5YfcT&M6 Location Project Deri am f ft Form 1 Documented by ffRi' Date SITE DESCRIPTION BLDG. DESCRIPTION Watt Roof Location Cod* Number (from Table 2 of Appendix 1) Latitude Degree Day»*e*ting (from Table 2 of Appendix 1) SF. Solar Factor (from Fig. 4.1.17 or Table 2 of Append* 1} AT. ASHRAf design tamp - 78° (from Table 2 of Appendix 1) Occupancy Type Cod* Numbtr (from Table 1 of Appendix 1) Grow heetwJ floor BTM. aq. ft. I^Z'x ^l' Numb»r of floort Ground Floor Pwim«t»r, ft. Lonont diaQonel dimemlon it ground floor, ft ftecartf th* ttotallfd mitfriib drta on th* MatenEW* Data Form • Form 2 Surface Area* Aopequ«wBit 12 14 12 wlHMr Heat Transfer Coafficienti (ne Section 4.1. (oeoMnei Shading coefficient of gtan, (from Table 3 of Appendix 1) Weight of Wall Construction, lb/ft2 Man Correction Factor (from Fig. 4.1.16) Equivalent Temperature Difference (from Fig. 4.1.16) Surface Areas **l 16 17 18 U SC 22 w 23 MCF 24 TD^, 25 Aop«qu« roof 26 27 28 (37/28) 29 Mote: /r* t/n* 29 It 8% or gr»*t*r, switching syttimi an nquind fa #* m* ItytxJ by tky- Enter the difference between line 27 and 6% of line 28, or ztro, whichever it the greater Enter the sum of line 36 and line 30 30 31 e 7 J&4 8 1 Q 10 11 1A BUILDING DATA FORM - BUILDING ENVELOPE COMPLIANCE PROJECT TITLE &J2&. fe P»fje 2 of Form 1 winter Floor Haat Transfer Cocfflcwnti (Saa Saction 4.1.8) (oooKnt) Shading Coafftctont of skylight (from TaMa 3 of Appendix 1) Man Coaffictat (from Fig. 4.1.16) Afaaorptanc* (from Fig. 4.1.16) Floor Area ovac unh**tad apaot U-vafut for floor HEATING OC8IQN CRITERION Standard U^ (from Fig. 4.1.2) Standard Uw (from Fif. 4.1 .3) Standard Uof (from Fig. 4.1.4) Maximum allowvbtt Uo (from Fig. 4.1.1) Propotad UQW (from Fig. 4.1:7) Propoiad Uw (from Fig. 4.1.10) Propoiad U0| (from Una 40) ; " PropoMdU0 (from Fig. 4. 1.1) Matt: Uw thf awrtfon of Fig. 4.1.10 for tt* propoud building taing tfw value from tin* 30 for tfw of tkytigriti, and th* vtiut from Urn 31 for tht ovtrtll roof COOLING DESIGN CRITERION Standard OTTWW (from Fig. 4.1.16) Standard OTTVr (41 x line 44} Standard OTTV (from Fig. 4.1.13) Propowd OTTVW (from Fig. 4.1.14) PropowdOTTVr(from Fig. 4.1.14) Propowd OTTV (from Fig. 4.1.13) Not*: O TTVr for OS* propond building it cafcu/atarf from th* *fu*ooti of Fig. 4.1.14 tmiflg tfw wiu* from Urn 27 forth* araa of tkylightt, *nd the v»k# from Im* 28 forth* ovtrtli roof Uf0of 32 33. Ur 34 U, 36 SC, 36 Me 37 AC 38 Aof 39 Uof * 43 44 46 47 48 49 — SO ' ' I Lin* 50 mutt not Iint4« a 64 SB Lint 66 murt not line 53 CgrreiaA 60^2.-*- (J . fo- OTTV - 4 x fc x or TV » _ A OTTV 4.1 A AW DOCUMENTATION FORM HVAC SYSTEMS COMPLIANCE (Complete for each system)Form 4 UM t (Riv. 1 5/78) Project Thta Lotion Project Designer. V STcM t (?ft. Docunumted Pet. Checked by bv &• M f *- Date DESIGN CONDITIONS Building occupancy typ« {Table 1 of Appendix I) ' ./**-'_~± Project Latitude (Table 2 of Appendix t) -^ \x' Heating Degree Days (Table 2 of Appendix I) / v ^ ^- HEAT1NG LOAD DOCUMENTATION (Attach calculations) i " ., t -, -; v --i, - Z/v'/ "*!/ Outdoor Design Temperature. Winter JJrV °F**A.iZ.4X3/- yu,il lndoor0esign 8 Timpemurl _00_°F X . £>*n 3y - J./ 76. / Outdoor Air " CFM /i"36 V /, / 5 X ••?' ^ ^"3 ^^ Haat Lou From Outdoor Air 8tu/Hr. />f2-8 X .^>*>/ ^' -' 2 2. jj *f I Temperature of adjacant unheated spaces ' °F / 7^ ^-'59 Transmiuion Heating Losses /'7VZ5^ Btu/Hr. Infiltration Air ^C^y/ CFM Heat Lou From Infiltration $ iStftt- atu/Hr Ventilation Air " CFM Heat Lou From Ventilation "- -, Btu/Hr. LJL?-L- - \ ]'3> 3 H-1- Outdoor Air for Special Processes CFM t f Q % ' Heat Lou From Process Air BtWHr. Other Hen Losset (detcritwl ' Stu/Hr. TotaJ Heat LOSM '. . . 7'^ f » Btu/Hr. COOLING LOAD DOCUMENTATION (Attach calculation!) Outdoor Design Temperature, summer, dry bulb Outdoor Design Temperature, summer, wet bulb 'jf>_ °F Indoor Design Temperature, summer, dry bulb ^ °F Indoor Design Temperature, summer, wet bulb ^ '7 2~ QF Transmission Heat Gain Lf^Lf^^ atu/Hr Inflltrition Air —.^(-^( „ &M Heat Gain From Infiltration .^/>A f>6-S 8tu/Hr. Outdoor Air for Special Processes ^Z.— CFM ( Heat Gain for Proceu Air * * Btu/Hr. Solar Haat Gain Through Windows, etc. /' •* T^ Btu/Hr. Heat Gain From Lights, Equipment, People, etc. .^ 2 ^Uj. Btu/Hr. Heat Gain From Other Sources \ Outdoor Air: Fixed Minimum Type Sysam CFM Per Person (Not to Exceed Tabulated — ' Minimum Ventilation Rates) • CFM/Penon Hiat Gain From Outdoor Air —~~ Btu/Hr. WOODSIDE KUBOTA & ASSOCIATES, INC. CONSULTING ENGINEERS 2465 Pio Pico Drive - P.O. Box 1095 • Carlsbad, California 92008 • (714) 729-1194 August 24, 1979 Mr . Ray Gr een "t;••••."•. Ci ty of Carl sbad '•*'.' Build ing Department 1200 Elm Avenue Carlsbad, California 92008 Subject: Proposed Business-Industrial Development Parcel "A", Lot 12, Palomar Airport Business Park Carlsbad Tract 79-1 Carlsbad Municipal Water District Dear Mr. Green: This letter is to confirm our telephone conference of yesterday at which time the undersigned advised your Department that the Carlsbad Municipal Water District will provide public water service to this proposed project. We have had one meeting already with Mr. Paul M. Thomas, Jr., representing the development firm of Thomas-Hensey- Nicol Company, and we have an understanding that the engineering consultants for the project will submit to the District and to the City Fire Marshall a proposed public water system 1 ayout which will meet the needs of the project. We have advised you that the District has no objections for the City of Carlsbad to issue a building permit for commencement of the project and we shall advise you at such time the entire public water system is completed and occupancy can be granted. Please contact Mr. F. J. Uhitley or the undersigned if you have any questions. Very truly yours , / Jack Y'. Kubota ,' Di strict Engineer Carlsbad Municipal Water District cc: Carlsbad Municipal Water District MrV Paul M. Thomas, Jr. Mr. John J. Kleeb JYK:gs CMWD 79-204 In Orange County, Santa Ana