HomeMy WebLinkAbout2251 FARADAY AVE; ; CB151201; PermitCity of Carlsbad 06-01-2015 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB151201 Building Inspection Request Line (760) 602-2725 Job Address: 2251 FARADAY AV CBAD Permit Type: Tl Sub Type: INDUST Status: ISSUED Applied: 04/21/2015 Entered By: RMA Parcel No: 2120610400 Lot#: 0 Valuation: $818,748.00 Construction Type: 5A Occupancy Group: Reference# Plan Approved: 06/01/2015 Issued: 06/01/2015 Inspect Area Project Title: WASSERMAN MEDIA-18,900 SF OFFICE TO OFFICE Applicant: TIM SEAMAN PO BOX5955 CHULA VISTA CA 91912 619 993-8846 Building Permit $2,994.26 Add'I Building Permit Fee $0.00 Plan Check $2,095.98 Add'I Building Permit Fee $0.00 Plan Check Discount $0.00 Strong Motion Fee $229.25 Park Fee $0.00 LFM Fee $0.00 Bridge Fee $0.00 STD #2 Fee $0.00 BTD#3 Fee $0.00 Renewal Fee $0.00 Add'I Renewal Fee $0.00 Other Building Fee $0.00 Pot. Water Con. Fee $0.00 Meter Size Add'I Pot. Water Con. Fee $0.00 Reel. Water Con. Fee $0.00 Green Bldg Stands (SB1473) Fee $33.00 Fire Expedidted Plan Review $0.00 Total Fees: Plan Check #: Owner: A&M CAPRE F R C L L C ATTN:MARK A VELARDE 2321 ROSECRANS AVE #4205 EL SEGUNDO CA 90245 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee Green Bldg Standards Plan Chk TOTAL PERMIT FEES $6,830.27 Balance Due: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $182.00 $1,110.00 $185.78 $0.00 $0.00 $0.00 $0.00 ?? ?? $6,830.27 $0.00 Inspector: Clearance: _____ _ NOTICE: Please take at approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." ou have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: OPLANNING OENGINEERING JOB ADDRESS "o- Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov SUITE#/SPACE#/UNIT# OBUILDING OFIRE OHEALTH OHAZMAT/APCD CT/PROJECT# PHASE# #OF UNITS # BEOROOMS # BATHROOMS TENANT BUSINESS NAME ~ e,. s ':,A.{ ~"'<'.c..-(\ CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) \~ ~IJD J GARAGE (SF) \) ~\-"-'\ STATE C..,.,~ ZIP O\\°\\ . FAX DESIGN PROFESSIONAL ADDRESS CITY STATE ZIP PHONE FAX EMAIL STATELIC.# PATIOS (SF) DECKS (SF) PROPERTY OWNER NAME CITY PHONE EMAIL CONTRACTOR BUS. NAME ADDRESS CITY AIR CONDITIONING FIREPLACE YESO NoD YEs0No0 ~ j\-.\-~ \lo 1::ie..c( """"' ~ \. STATE \.I\.['\ C' \) U) FAX FIRE SPRINKLERS YEsONoO (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)). 'i ,Y,v' , ',,/, /,',~,::., / , , , ~ , , , ,, ,, ,W/~l, ', Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following decfaraffons: D I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers_;;o111~ensatlon, as reqjlir~51,b;t. s._ect~700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance ca,!Jiltr and policy number are: Insurance Co. :::r?o/ I · 'e. <-OT y'-1-Policy No. Oz I I ;;J,t,<.,p 's 'd-c> 1 <.../ Expiration Date 1 () } I b This section need not be completed tt the permit is for one hundred dolla ($100) or less. 0 Certificate of Exemption: I certify that in the pert rmance of th rk for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of addition to the cost of compensation, damages s ovided fo i lion 37 ·the Labor code, interest and attorney's fees. /. / California. WARNING: Failure to secure worke ompensat' n overage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hu(dre,thousand dollars (&100,000), in ,2$ CONTRACTORSIGNATURE---J AGENT DATE ~ \ \) I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed pursuant to the Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: . 1. I personally plan to provide the major labor and matertals for construction of the proposed property improvement OYes 0No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): ,2$ PROPERTY OWNER SIGNATURE 0AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No ' IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. '',',:',,,,',,,/> I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certifylhatl have read 1he application and state1hat1he above lnfonnation is conectand 1hatthe lnfonnation on the plans is accurate. I agree to complywith all Cityordinancesand State laws relating to building construction. I hereby authorize representative of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permitissued by the Buildingf.')fficial under the · visions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the bu' in or work autho · by such permit is suspended or abandoned at anytime after the work is commenced fora period of 80 days (3E\clion 1~4 Uniform Building Code). ~ APPLICANT'S SIGNATURE DATE l\ 0\ \ \ ) STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCY (Commercial Projects On f y} Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. I CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. i) MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) ASSOCIATED CB# CONTRACTOR (On Pg. i) NO CHANGE IN USE/ NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION ,25 APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB151201 Type: Tl INDUST WASSERMAN MEDIA-18,900 SF OFFICE TO OFFICE Date Inspection Item !!_"i_spector Act Comments 08/18/2015 89 Final Combo PY AP 08/18/2015 89 Final Combo RI COF 08/06/2015 89 Final Combo RI WANTS A PRE-FINAUFIRE ON FRIDAY 08/06/2015 89 Final Combo PY NR 08/05/2015 29 Final Plumbing PY NR 08/05/2015 29 Final Plumbing PY NR 08/03/2015 39 Final Electrical PY NR 07/29/2015 34 Rough Electric PY PA 07/27/2015 85 T-Bar PY AP 07/16/2015 17 Interior Lath/Drywall PY AP 07/10/2015 17 Interior Lath/Drywall MC AP AT TOP OF RM 128-131 07/10/2015 84 Rough Combo MC AP HARD LID RM 137 07/07/2015 15 Roof/Reroof PY AP 07/07/2015 17 Interior Lath/Drywall PY AP 07/06/2015 14 Frame/Steel/Bolting/Weldin PY PA 07/06/2015 17 Interior Lath/Drywall PY PA 07/02/2015 34 Rough Electric PY CA 06/29/2015 14 Frame/Steel/Bolting/Weldin PY PA 06/29/2015 1.7 Interior Lath/Drywall PY PA 06/24/2015 84 Rough Combo PD PA 06/18/2015 17 Interior Lath/Drywall PY PA 06/18/2015 31 Underground/Conduit-Wirin PY AP 06/16/2015 14 Frame/Steel/Bolting/Weldin PY AP 06/16/2015 17 Interior Lath/Drywall PY PA 06/16/2015 34 Rough Electric PY PA 06/15/2015 21 Underground/Under Floor PY AP 06/10/2015 14 Frame/Steel/Bolting/Weldin PY PA Wednesday,August19, 2015 Page 1 of 1 ' ·1 • • ' •• • • :.:. ' • . . ., -~ POOR U LI . I I I . . .~-i.-51 [titr (t; lW J ~CORri:Cr;JPY .,'\':· l l j ·1 . j EsGil Corporation In <Partnership with government for (}Jui(aing Safety DATE: 5/20/2015 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-1201 PROJECT ADDRESS: 2251 Faraday Ave. PROJECT NAME: Wasserman Group Office T. I. SET: II D APPLICANT D JURIS. D PLAN REVIEWER D FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: Mail Telephone D REMARKS: By: David Yao (by: Telephone #: ) Email: Fax In Person Enclosures: EsGil Corporation jg! GA jg! EJ O MB O PC 5/14 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In (}!artnersliip witli qovernment for (}Jui{aing Safety DATE: 4/30/2015 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-1201 PROJECT ADDRESS: 2251 Faraday Ave. PROJECT NAME: Wasserman Group Office T. I. SET: I ~PPLICANT £ ~URIS. CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. r:8'.] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. r:8'.] The applicant's copy of the check list has been sent to: Tim Seaman D EsGil Corporation staff did not advise the applicant that the plan check has been completed. r:8'.] EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Tim Seaman Telephone#: 619-993-8846 ))ate contacted: 'tf 30 (by:'/'JA-r Email: tim@bhpsonline.com 1;:Mail (~e~ephone FaD In Person D REMAM:,t')\' +:tJ l l By: David Yao Enclosures: EsGil Corporation rgJ GA rgJ EJ O MB D PC 4/23 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' j City of Carlsbad 15-1201 4/30/2015 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 15-1201 OCCUPANCY: B TYPE OF CONSTRUCTION: VA ALLOWABLE FLOOR AREA: ? SPRINKLERS?: Y REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4/21 DATE INITIAL PLAN REVIEW COMPLETED: 4/30/2015 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: office ACTUAL AREA: T. I. 18900 sf STORIES: 1 HEIGHT: OCCUPANT LOAD: -428 DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/23 PLAN REVIEWER: David Yao This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. ' City of Carlsbad 15-1201 4/30/2015 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. . 2. 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) - 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 107.2. In rooms or areas where the occupant load exceeds the values in the table below, two exits shall be provided. Section 1015.1. Where are the two exits from break room? Door 101A to the center of hall entrance appears to be less than 1 /3 of the area it serves? Exit sign? OCCUPANCY MAXIMUM OCCUPANT LOAD B 49 3. Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served. Section 1015.2.1. Where a building is equipped throughout with an automatic sprinkler system, the separation distance may be reduced to one-third of the diagonal. 4. Note on the plans: "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort." Section 1008.1.9. In lieu of the above, in a Group B, F, Mor S occupancies (or places of religious assembly or Group A occupancies having an occupant load of 300 or less), you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." This signage is only allowed at the main exit. Section 1008.1.9.3. 5. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1011.1. 6. Show that the means of egress path will be lighted with at least one foot candle at floor level. Section 1006. , City of Carlsbad 15-1201 4/30/2015 7. Show separate sources of power may be required for exit illumination. Review Section 1006.3. • ACCESSIBILITY • COUNTERS AND TABLES 8. The tops of tables and counters shall be 34" maximum above the floor. Section 11 B-904. Where a single counter contains more than one transaction station, such as a bank counter with multiple teller window or a retail sales counter with multiple cash register stations, at least one of each type of station shall be located at a section of counter that is at least 36" long and no more than 28" to 34" high. Section 11 B-904. (reception counter?) 9. Sales and service counters shall have a portion of the counter which is at least 36" in length with a maximum height of 34 inches. Section 11 B-904.4.1. • NON-RESIDENTIAL GREEN BUILDING STANDARDS (Additions and Alterations) The California Building Standards Commission (BSC) has adopted the Green Building Standards Code which became effective January 1, 2011, and must be enforced by the local building official. The Green Building Standards apply to nonresidential additions or tenant improvements throughout California. These standards apply to nonresidential additions of 1,000 sq. ft. or larger or alterations (tenant improvements) with a value of $200,000 or more. CGC Section 301.3. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 10. Light pollution reduction. Note on the plans that exterior light pollution must comply with CGC section 5.106.8. 11. Waste management. Note on the plans that the contractor must submit to the Engineering Department or other Agency that regulates construction waste management a Waste Management Plan that outlines the items listed in CGC Section 5.408.1.1. 12. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 5.408.1. Documentation shall be provided to the enforcing agency which demonstrates compliance. CGC Section 5.408.1.4. 13. Recycling. Note on the plans that an identified, readily accessible area shall be provided that serves the entire building for collecting recycling, such as paper, cardboard, glass, plastics, metals, etc. CGC Section 5.410.1. 14. Documentation. Note on the plans that a building "Systems Manual" as listed in CGC Section 5.410.2.5 shall be delivered to the building owner or representative ' City of Carlsbad 15-1201 4/30/2015 and the facilities operator. Further, note on the plans that the "Systems Manual" shall contain the required features listed in CGC Section 5.410.2.5.1. 15. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 5.504.3. 16. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 5.504.4 and Tables 4.504.1, 5.504.4.1 5.504.4.2, 5.504.4.3 and 5.504.4.5 for: Adhesives, Sealants, Paints and Coatings, Carpet and Composition Wood Products. CGC 5.504.4. 17. Pollutant control. Note on the plans that mechanically ventilated buildings shall provide regularly occupied areas with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 8. MERV 8 filters shall be installed prior to occupancy. CGC Section 5.504.5.3. 18. Environmental comfort. Note on the plans that wall assemblies separating tenant spaces (and tenant spaces from public spaces) shall have an STC of at least 40. CGC Section 5.507.4.3. 19. Outdoor air quality. Note on the plans that installations of HVAC, refrigeration and fire suppression systems will not contain CFC's or Halons, per CGC 5.508.1. 20. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102'.3. • ADDITIONAL 21. Please refer to the following corrections for mechanical, plumbing, electrical and energy items. 22. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 23. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: D Yes D No 24. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any ' City of Carlsbad 15-1201 4/30/2015 questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. PLUMBING AND MECHANICAL CORRECTIONS + PLAN REVIEW NUMBER: 151201 PLAN REVIEWER: Glen Adamek SET: I GENERAL AND ARCHITECTURAL PME ITEMS 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. Clearly show the existing use of this tenant space. Provide demo plans. Plumbing plans show an interior grease interceptor being removed. Was this an auto repair garage? 3. Clearly show the existing use of the adjoining tenant space. Check for occupancy of the adjoining tenant space and any required fire rated separations. 4. Please provide a copy of the existing envelope energy design and provide a demo plan showing the existing HVAC units that conditioned the complete tenant space. The plans seem to show only the office #126 was conditioned and the rest of the tenant space was unconditioned space. Provide envelope energy design for the existing non-conditioned space now being conditioned with the new HVAC units. 5. Detail the fire rated roof/ceiling system showing the fire rated ceiling membrane for the Type V-A construction. 6. Include, on the mechanical plans, the locations of all required smoke, fire, combination smoke and fire, or ceiling radiation dampers. Be sure to include a symbol on the symbol schedule for each damper type. CBC 716 7. Please detail roof access to roof mounted HVAC equipment, including roof access hatch and roof access ladder. CMC 304.2.1.2 . City of Carlsbad 15-1201 4/30/2015 8. Please correct the drawings to show the required 42 inch tall "Guards" (guard rails) as per CBC, Sections 1013.6 & 1013.7: Where appliances, equipment, fans, roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface. PLUMBING (2013 CALIFORNIA PLUMBING CODE) 9. Provide calculations to show compliance with CPC Section 422 & Table 422.1. (Minimum Plumbing Facilities). Please include the required drinking fountains. No drinking fountains provided on the plans. 10. Provide the site plumbing plans showing the sizes and locations of the gas meters and water meter; and the sizes, routes, and slopes of the building sewer, site gas lines, and site water lines. 11. Show the existing public water meter that serves this tenant space and show all existing and proposed future water demands proposed on the public water meter. If the public water meter serves only this tenant space show the other water meters serving the rest of the building. (The plumbing plans seem to show one public water meter serves the total building.) 12. For backwater valve review, please show the upstream sewer manhole rim elevation (manhole cover elevation) and finished floor elevations. CPC 710.0 Backwater valves are: a) Mandatory: Fixtures installed on a floor level below the next upstream manhole cover elevation require backwater protection. b) c) Optional: Fixtures installed on a floor level below the next upstream manhole cover elevation however they (the fixtures) are not below the manhole cover. Not Allowed: For waste systems with fixtures installed on a floor level above the next upstream manhole cover elevation. 13. Please provide sizing calculations for the existing and new water lines from the pubic water meter to the new water lines in this tenant space. Include the water pressure, pressure loss calculations, water demands, and the developed pipe lengths. CPC 610.0 or Appendix 'A'. Data on sheet P0.1 is not water line sizing calculations. 14. Please show the sizes on all existing vents in the existing vents in the rest of the building to show compliance with CPC, Section 905.1. 15. Detail now the condensate from the fan coil unit FC-1 is to be drained up to condensate drain line for roof mounted HVAC units. 16. Show all new pipe sizes on the drain, waste and vent piping plans. 17. Detail how the floor drain trap seal is to be maintained. CPC 1007.0 . City of Carlsbad 15-1201 4/30/2015 18. Floors shall slope to the floor drain(s) location(s). Please detail on the architectural floor plans. CPC 418.5 19. Describe the method of compliance for temperature limitations for the public use lavatories (limited to 110 degrees). Note: The water heater thermostat may not be used for compliance with this Code section. CPC 421.2. Energy Standards 11 0(C)3. 20. Hot water recirculating loop systems requirements (Not single family homes): 2013 CEC 110.3Detail the following: a) The installation of an air release valve on the inlet side of the recirculation pump, within 4' of the pump. b) A check valve is required between the recirculating pump and the water heating equipment to prevent the hot water from flowing backwards through the recirculation loop. c) A check valve is required on the cold water supply line between the hot water system and the next closest tee on the cold water supply line. (See CPC 608.3 for expansion tank requirements.) MECHANICAL (2013 CALIFORNIA MECHANICAL CODE) 21. Review with the architect the locations that require (fire/ceiling radiation/or fire/smoke) dampers and/or shaft protection and identify installations on the mechanical plans themselves. 22. Correct the ventilation calculations in the energy design on NRCC-MCH-03-E forms for HP-1 & HP-3 serving the Break Room #102, HP-10 Serving Meeting Room 137 & offices, and HP-15 serving Meeting Room #124 & offices for the larger required ventilation rates in the meeting rooms and break room. Correct the required minimum ventilation rates and the proposed outside air amounts to agree with the corrected calculations. 23. Please address the use of the Den and correct the required ventilation rates (outside air amounts) as per corrected NRCC-MCH-03-E forms for the use in the Den. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE) 1. The electrical submittal was not complete. Electrical plan review will commence after completed plans have been submitted. City of Carlsbad 15-1201 4/30/2015 ENERGY (2013 CALIFORNIA BUILDING ENERGY STANDARDS) o The energy design is fine as submitted. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF DOCUMENT City of Carlsbad 15-1201 4/30/2015 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao BUILDING ADDRESS: 2251 Faraday Ave. BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier office T.I. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review D Repetitive Fee 3 Repeats D Other D Hourly EsGil Fee PLAN CHECK NO.: 15-1201 DATE: 4/30/2015 Reg. VALUE ($) Mod. per city 818,748 818,748 $2,994.261 $1,946.271 D Structural Only -----IHr.@ • $1,676.791 Comments: review. :In addition to the above fee, an additional fee of $43 is for the CalGreen Sheet 1 of 1 macvalue.doc + ./. . «1t ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL DATE:04/27/2015 PROJECT NAME: Tl OFFICE TO OFFICE PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2251 FARADAY AVE VALUATION: $818,748 Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov PROJECT ID: CB151201 APN: /' This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: VALRAY NELSON A Final Inspection by t_he ENGINEERING Division is required Yes ,; No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: TIM@BHPSONLINE.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: .. PLANNING ENGINEERING. FIRE PREVENTION 760-602-4610 760-604-2750 160-602-4665 Chris Sexton Kathie.en Lawrence Greg Ryan 760-602-4624 760-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov if ValRay Marshall Dominic Fieri 760-602-2773 760-602-4664 ValRay.Marshall@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: ~···.·· ~ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for C8151201 Date:04/27/2015 Project Address: 2251 FARADAY AVE Project Description: Tl OFFICE TO OFFICE 18,900 ENGINEERING Contact : VALRA Y NELSON Phone: 760-602-27 41 _ .: RESIDENTIAL INTERIOR c·.·1 RESIDENTIAL ADDITION MINOR (<$20,000.00) CJ CARLSBAD PREMIER OUTLETS r -, OTHER: GYM .•.• 1 APN: Valuation: $818,748 Email: VALRA Y.MARSHALL@CARLSBADCA.GOV Fax: 760-602-1052 QJ TENANT IMPROVEMENT 0 PLAZA CAMINO REAL [] COMPLETE OFFICE BUILDING r .. -. ··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··, OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: VALRA Y NELSON REMARKS: Tl OFFICE TO OFFICE 18,900SF ALL FEES ON CB090919 DATE:04/27/2015 Notification of Engineering APPROVAL has been sent to TIM@BHPSONLINE.COM via VALRAY.MARSHALL@CARLSBADCA.GOV on 04/27/2015 -··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-··-· E-36 Page 1 of 1 REV 4/30/11 ···-·-----------·1 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: Date: 04/27/2015 GEO DATA: LFMZ: / B&T: Bldg. Permit#: CB151201 Address: 2251 FARADAY AVE Fees Update by: Date: 04/27/2015 Fees Update by: Date: 04/27/20ti EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units Types of Use: Types of Use: Types of Use: Sq.Ft./Units Sq.Ft/Units Sq.Ft./Units ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units Types of Use: Sq.Ft/Units Types of Use: Sq.Ft./Units Types of Use: Sq.Ft.JU nits FEES REQUIRED: EDU's: EDU's: EDU's: . EDU's: ADT's: ADT's: ADT's: ADT's: Within CFDtJYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) · ·:No 1. PARK-IN-LIEU FEEJ--:::NW QUADRANT ADT'S/UNITS: I X 2.TRAFFIC IMPACT FEE: ADT'S/UNITS: I X 3. BRIDGE & THOROUGHFARE FEE: ADT'S/UNITS: ~ 4. FACILITIES MANAGEMENT FEE ADT'S/UNITS: I X 5. SEWER FEE EDU's IX BENEFIT AREA: EDU's IX 6. DRAINAGE FEES: PLDA: ACRES: IX 7. POTABLE WATER FEES: i71NE QUADRANT r·1sE QUADARANT L)SW QUADRANT FEE/ADT: I=$ D FEE/ADT: r I DIST. #1 FEE/ADT: ZONE: I=$ [JDIST.#2 1=$ FEE/SQ.FT./UNIT: I =$ FEE/EDU: I =$ FEE/EDU: :··-!HIGH FEE/AC: I=$ ['~:1MEDIUM I=$ D CJDIST.#3 D D D D D UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL I PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.1mv DATE: 4/22/15 PROJECT NAME: T.1.-0FFICE TO OFFICE PROJECT ID: PLAN CHECK NO: CB151201 SET#: ADDRESS: 2251 FARADAY AV APN: C8:I This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required ~ Yes *TO ENSURE COMPLIANCE WITH THE ROOF MOUNTED SCREENING SHOWN ON SHEET M2.2 0 No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: TIM@BHPSONLINE.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: D D D PLANNING ENGINEERl·NG FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton D Chris Glassen D Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christo11her.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz D ValRay Marshall D Cindy \/\long 760-602-4675 760-602-2741 760-602-4662 Gina.Ruiz@carlsbadca.gov Va1Ray_.Marshall@carlsbadca.gov Cy_nthia.Wong@carlsbadca.gov D Linda Ontiveros D Dominic Fieri 760-602-2773 760-602-4664 Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: POLICY AND SECTION FOR ROOF MOUNTED EQUIPMENT ON SHEET M2.2 ~~ ¥' CITY OF CARLSBAD PLAN CHECK REVIEW TRANS MITT AL <f.,f Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov -it: -,.h., DATE: 5/28/15 PROJECT NAME: Wassermann Media Group PR'CiU:~T ID: PLAN CHECK NO: cb1512O1 SET#: II ADDRESS: 2251 fara~~ APN: [><J This plan check review is complete and has been APPROVE~e fire Division. By: cwong A Final Inspection by the Division is required [Z! Yes D N~ D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent tim@bhpsonline.com & USPS You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. 'For questions or clarifications on the attached checklist please contact the following reviewer as marked: D Chris Sexton 760-602-4624 Ch ris.Sexton@carlsbadca.gov D · Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov D Remarks: 5/28/15 ** APPROVED: · D Kathleen Lawrence 760-602-27 41 Kath leen.Lawrence@carlsbadca.gov D Linda Ontiveros 760-602-2773 D Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov ~ CindyWong 760-602-4662 Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D D Dominic Fieri Page 1 of2 •. 760~602-4664 P<>'QlJnlb,fli:!tl@carlsbadca.gov . THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. 5/7/2015 ***Bubble All Changes*** 1. Sheet M0.1: Add the following note to the Mechanical General Notes: Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an-audible, local alarm shall be required. CMC, 201.3 edition, section 608 and NFPA 72. 2. Sheet M0.1.:Add the following note to the Plan Notes: Air moving systems supplying air-in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC, 2013 edition, section 608 and NFPA 72. 3. Sheet E1.3: Add to Legend fixtures that have 90 minute battery backup. 4. Sheet E2.1: EB shall be located along MOE as shown on sheet A0.4. Make these changes not add as note. ;',_,_,.f i::_i~i:'("/ ~: '-t;.-' 5. Sheet A0.5: Add note that confirms that doors with card readers shall allow for free "f : -} 1:t" • ' , . egress without car~ reader: State if mag lock or not. ..... ·.J; .)' \'r_,.t ' ,. ' . Page 2 of2 ' .. _Carlsbad Fire Department Plan Review Requirements Category: TI , INDUST Date of Report: 05-28-2015 Name: Address: Permit#: CB151201 TIM SEMAN PO BOX 5955 CHULA VISTA CA 91912 Job Name: WASSERMAN MEDIA-18,900 SF Job Address: 2251 FARADAY AV CBAD 1ew 1s incomplete. At this time, this office cannot adequately ~onduct a review o liance with the applicable codes and/or standards. Please review carefully all commen c ed. Please resubmit t e sand/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0008257 [NOT MET] ***Bubble All Changes*** 1. Sheet M0.1: Add the following note to the Mechanical General Notes: Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC, 20-13 edition, section 608 and NF.rftf 72·;':! t_:·-. . · .. .,. i.J· ;t\\· 3:\3 .. _;: :-:;.. , . : . .. ', , ._. ~ . , , , 2. Sheet M0.1 :Add the folloyvi_ij)f note to the Plan Notes: ~ ·\ ::-e·:;: i -~~"?~~t;i:~j}_~_:~ ~\.f," ·. · · .-· -, , - Air moving systems suppiyfo.g'qir in e~ceas pf 2000 cubic feet/minute shall ·be_·equipped with smoke duct detectors and be tiecl, "in-to-the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC, 2013 edition, section 608 and NFPA 72. ' 3. Sheet El.3: Add to Legend fixtures that have 90 minute battery backup. 4. Sheet E2.1: EB shall be located along MOE as shown on sheet A0.4. Make these changes not add as note. 5. Sheet A0.5: Add note that confirms that doors with card readers shall allow for free egress without card reader. State if mag lock or not. Entry: 05/07/2015 By: cwong Act~on: CO Cond: CON0008306 LMETJ 1 • I ,. ** APPROVED: t::::: --~ THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Nam~: Address! Permit#: CB1Sl201, R~quirf#ments Category: TI , INDUS? TIM SEMAN POBOX5955 CHULA VISTA CA 91912 Job N;une: vVASSERMAN MEDJA .. 18,900 SF Job Address: 22Sl FARADAY AV Cl3AD INCOMPLETE The it~m yoµ have submitted fo:r re;view is incomplete. At this tim:e, this office cannot adequately conduGt a, review to d!;ltenn,in~ complianc~ with the applicable co<;les and/or standards. Please review car~fully all comments attached, Please resubmit the necessary plans and/or specifications1 with changes "clouded", to this office for review and approval. Con~:-C_ON00032S7 [NOT MET] 1, She~t MO. 1: Add the following note to the MechaJ1iQa.l General Notes: Air moving systems supplying aidn ~xcess of 2000 cubic f~et/minute sha,11 be equipped with smoke duct detectors and be tied in to tl~e building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC, 20_13 edition, section 608 and NFPA 72. 2. Sheet M0.1 :Add the following note to the Plan Notes: Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC, 2013 ~dition, section 608 and NFP A 72. -3, Sheet E 1.3: Add to Legend fixtures that have 90 minute battery qackup. 4. Sheet E2. l: EB shall be located along MOE as shown on sheet A0.4. Make these changes not add as uote. 5. Sheet A0.5: Add note that confirms that doors with card read~rs shall a,Ilow for free @gre.s& without card l'eader. State if mag lock or not. Entry: {)5/07 /2015 By; cwong Action: CO OFFICE USE ONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE UPFP# ______ _ HV# ________ _ BP DATE_~'--~-- Telephone# i!O ~ \A? 7, • oi.oo State CA- Zip Code APN# ~'1..00 S. '2..\'2-· Ol&,,\ · 0 Mailing Ad ress ll City State Zip Code Plan File# ,, C:::PJ·\"1·\'2,.o Project Contact~ \'fr-\ \V\vL-L~ Telephone# \ o '2.-o'2.. · ~c..,.o o The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): t'b, ~oo ~f: Occupancy Rating: 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISIONS (HMO): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 11 O, San Diego, CA 92123. Cali (858) 505-6700 prior to the Issuance of a building permit. 0 CalARP Exempt I FEES ARE REQUIRED. Project Completion Dale: ":t--,.1:j_, l ~ Expected Date of Occupancy: _3:_, '10 t I C:, YES NO -----(for new construction or remodeling projects) 1. 2. 3. 4. 5. 6. 7. 0 ;g ls your business listed on the reverse side of this form? (check all that apply). 0 g Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 .l8f Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons. 500 pounds D D D D 200 cubic feet, or carcinogens/reproductive toxins in any quantity? 1E{' Will your business use an existing or install an underground storage tank? .l8f \Nill your business store or handle Regulated Substances (CalARP)? S \Nill your business use or install a Hazardous Waste Tank System (Tltle 22, Article 10)? }sf \Nill your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). Dale Initials D CalARP Required I Date initials 0 CaiARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer lo any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the lssuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. YES NO 1. D ;g_ Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facts/permlts.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. ContactAPCD if you have any questions). 2. D ~ (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http://www.cde.ca.gov/re/sd/ for public and private schools or contact the appropriate school district). 3. Has a survey been performed to determine the presence of Asbestos Containing Materials? 4. 5. D D D I \Nill there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-frlable asbestos? \Nill there be demolition involving the removal of a load supporting structural member? Briefly describe business activities: ~'?\ "1~'7'7 I D ffLc./4 Briefly describe proposed project: '1' '-\....I. ~'i" l M Pf2.-o"1. ~ \A,' N '\ · I decl re under penalty o perjury that to the best of my knowledge and belief the responses made herein are true and correct. ,c (.;; . ~ I "? I llz Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _____________________________ _ BY: _______________________ _ DATE:---'-/ _____ / __ _ EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMO APCD • A stamp In this box only exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other permitting requirements may still apply. INDUSTRIAL WASTEWATER DISCHARGE PERMIT Date C:.,. c; ·t~ SCREENING SURVEY Business Name V\I A~~ ~lt-tv\A-N M~O I A t,,,,i-c>u? StreetAddress 2.2.C,t 'f'~po...'-{ p,.-.J(., l.A(Z.L.~:f,AO ez...ooe, Email Address ::\-:t, G-Y\ '('o ed e..,e, w ffl_:) LL c... c..o'iY"\ D PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining/ Milling Painting/ Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting I Forming Pesticide Manufacturing/ Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film/ X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap/ Detergent Manufacturing Industrial Laundry Waste Treatment/ Storage SIC Code(s) (if known): _____________________ _ Brief description of business activities (Production/ Manufacturing Operations):_N-1/~t:.-__ _ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): ~/)(- Estimated volume of industrial wastewater to be discharged (gal/ day): _N+/¥ _____ _ List hazardous wastes generated (type/volume):-~-/~:;;.._ ___________ _ Date operation began/or will begin at this location: ______________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No lfyes,when: ___________________ _ Site Contact {-;,16 l1'l-+ M \J LL-~f!,. · Title '(~t--1[:)..N'[ ~?. [ A.U !At 'Cl:.L.-f Signature ~ ~ Phone No. '1:7\0 · 1.-£>7--~te,oo ENCINA WASTEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 {760) 438-3941 FAX: (760) 476-9852 . ' \,I-~. ' ~ /4f~i' ~~·-v PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Building@carlsbadca.gov ~ CITY OF C RLSBAD B-18 Project Address: Permit No.: Information provided below refers to work being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains ....................................................... ~ New building sewer line? ......................................................................................... Ves __ No~ Number of new roof drains? ............................................................................................................... __Q_ Install/alter water line? ......................................................................................................................... _::(__ Number of new water heaters? ......................................................................................................... --1::.__ Number of new, relocated or replaced gas outlets? .................................................................... ...52_ Number of new hose bibs? .................................................................................................................. _Q__ Residential Permits: New/expanded service: Number of new amps: ______ _ Minor Remodel only: Yes__ No Commercial/Industrial: Tenant Improvement: Number of existing amps involved in this project: Number of new amps involved in this project: New Construction: Amps per Panel: Single Phase ............................................................... Number of new amperes __ N_._~----- Three Phase ................................................................. Number of new amperes. __ '2...00 _____ A:-___ _ Three Phase 480 ........................................................ Number of new amperes. __ 4..;,....oo __ A ___ _ Number of new furnaces, A/C, or heat pumps?............................................................................ \ C;:, New or relocated duct wor~? .......................................................................... Yes X No __ _ Number of new fireplaces? ................................................................................................................. _E_ Number of new exhaust fans? ............................................................................................................ __l__ Relocate/install vent? ............................................................................................................................ _!::::!__ Number of new exhaust hoods? ........................................................................................................ _Q_ Number of new boilers or compressors? ........................................................... Number of HP N 8-18 Page 1 of 1 Rev. 03/09 >~;;J,i-;.,, ;+:· .,,;·, _:,,.,. CB15120i 2251 FARADAY AV WASSERMAN MEDJA-18,900 SF OFFICE TO OFFICF 1/41/;5 0(7j 0Jo/JA-~ ~c!;///L-~{ f~ tff ;;)..~II 5" ~ ~ p-e. 6 /13 / ( S--]L -/tJ & 67 L +-h/e.e- S-/ ;;;of,S $}!¥1/1s b}r {,E: ~ · @, 1-==--c:.. fU..,.t.-d_ F1-re Ok- R..-yr -JV W J C-C)-(\. .-rcu:.--J-a-r 6 'd-' l'o.~ Final Inspection required by: OPlan OCM&I SW 01SSUE Approved BUILDING PLANNING ENGINEERING FIRE Expedite? Y(N_...} DIGITAL FILES Required? y N - HazMat APCD Health Forms/Fees Sent Encina Fire HazHealthAPCD PE&M C./ 1'11 /t"l School Sewer Stormwater Special Inspection CFD: y N LandUse: Density: lmpAre PFF: y N Comments Date Building rho/;$" . Planning Engineering Fire 1571/t:< Need? ' Let=t I ,J RJLO-e("