Loading...
HomeMy WebLinkAbout2257 BOCA ST; ; CB163426; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit 09-06-2016 Permit No: CB163426 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: PC#: Project Title: Applicant: 2257 BOCA ST CBAD PME 2163402300 SCHABER: REPLACE AIC OAK ISLAND HEATING AND AIR STE 103 1250 PACIFIC OAKS PL ESCONDIDO CA 92029 760 839-8383 Plumbing Fees Electrical Fees Mechanical Fees Other PME Fees TOTAL PERMIT FEES Status: Lot#: 0 Applied: Entered By: Plan Approved: Issued: Inspect Area: Owner: SCHABER FAMILY TRUST 12-18-03 2257 BOCAST CARLSBAD CA 92009 ISSUED 09/06/2016 SF 09/06/2016 09/06/2016 $0.00 $0.00 $163.00 $0.00 $163.00 Total Fees: $163.00 Total Payments To Date: $163.00 Balance Due: Inspector: FINAL APPROVAL .:; --2.1-11 Date: J. Clearance: $0.00 NOllCE: Aease ta<e CE thct I!.W(Mll ri ~ ll$d irdudes the "IITpCSitiai' ri fees, dedcai(J'IS, resE!I\IGti(J'IS, a ether ec<DiCJ'lS t'ereliter <DI~ l'l'ferred to as "fees/ea:.ticrs." You l'ava 00 days fran the date !lis perrrit Wl> issued to pt'dest i!TpCSiti01 ri these feeslea:.ticrs. If~ pt'dest tten ~ rrust fdlo.vthe pt'dest IJOCEl(ires sa forth in GMmrert Code Secti016002)(a), a"d file the pt'dest a"d Mf ether llQ.ired irtam:.ti01 wth the aty ~fa Jl'O(llSSirg in amdaalWth Ca1sba:l Mridpa Code Secti013.32.!m. Failt.J"etotirrelyfdlo.vthct Jl'OOld.rev.ill ber MfSlb>eq.Jert lega <di01toatta:k, r'EMew, sa aside, vdd, a anJ trar irrpcsiti01. You ere~ FI..RiltR NOll A ED ti-el~ rigt to pt'dest the spedfied feeslec<DiCJ'lS IXE) NOT APPLY tow:ter a"d 59M91'a:rredial fees a"d 03pEdty cl'a"ges. ra plarrirg, :zxrirg. ga::lrg a ether sinilar ~icati01 Jl'O(llSSirg a SIBI'\Ii~ fees in CXJI1Eldia1 wth !lis ~ed. I'I(R IXE) IT APPLY to Mf ~ . Wi . . 'nil . . li . . . . . THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0 ENGINEERING OBUILDING OFIRE 0HEALTH D HAZIIATIAPCD «~4)\ Building Permit Application Plan Check No. C~ l '=:, ~~~ 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value ~ CITY OF Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit CARLSBAD email: building@carlsbadca.gov www.carlsbadca.gov Date~~~~(.,;, ISWPPP JOB ADDRESS 2257 BOCA ST. . SUJJD/SPACI:f/UNir. IAPN -- - Gl/PROJECT # I LOT# I PH.OSE II r OF UNITS r BEDROOMS #BATHROOMS lll:NIINT BUiiiiiiUll NAME I CONSTR. TYPE I occ. GROUP DESCRIPTION OF WORK: Include Squ.-Feet of Nl'8ctlld ArN(a} REMOVE AND REPLACE 1 AJC UNIT, LIKE FOR LIKE EXISnNGUSE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE .I AIR CONDmONING II FIRE SPRINKLERS YES(]t#. N<Q YES0No0 YES0N00 APPLICANT NAME TOM WOOD PROPERTY OWNER NAME CAROLINA SCHABER p ADDRESS ADDRESS 1250 PACIFIC OAKS PL. #103 2257 BOCA ST. CllY STATE ZIP CllY STATE ZIP ESCONDIDO CA 92029 CARLSBAD CA 92009 PHONE I FAX PHONE I FAX 760 839-8383 760 839-8380 760·815·5999 EMAIL EMAIL INFO@()AKISLANDAC.COM DESIGN PROFESSIONAL CONTRACTOR BUS. NAME OAK ISLAND HEATING AND AIR ADDRESS ADDRESS 1250 PACIFIC OAKS PL #103 CllY STATE ZIP CllY STATE ZIP ESCONDIDO CA 92029 PHONE PHONE I FAX 760 839-8383 I FAX 760 839·8380 EMAIL EMAIL INFO@OAKISLANDAC.COM I STATE LIC. II STATELIC.# IClASSc-20 .lcrrvsus.uc.1212710 745400 .. (Sec. 7031.5 Busrness and Professrons Code: Arry City or County whrch requrres a perrnrt to construct, alter, rmprove, demolrsh or repair all)' structure, pnor to rts rssuanoa, also ~ulres the applicant for such permit to file a siilned statement tftat he is lioansed pursuant to the provisions of the Contractor's UCense Law IChaDter 9, commenc:tirl!f with Section 7000 of DiVision 3 of the Business and Professions Code) or Blat he is exempt; therefrom, and the basis for the alleged exemption. Arry violation of Section 7031.5 by any applicanffor a permit subjects the applicant to a civil penally of not more than fiVe hundred dollars {$500)). WORI<ERS' COMPENSATION Workenl' Compenslllon Decllnlllon: I hflreby 8fflnn under PfiiiBIIY of petjuty one of the folk1Mng declsnlllons: 0 I have and wlllllllllnllln a certlflcll8 of consent to lilt-Insure for WQI1(ers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permft is issued. [l] I have and wlllllllllntlln workers' ~. as teQUir8d bv Section 3700 of the Labor Code. for the performance of the \Wilt for which this permft is Issued. My wokers' compensation insurance carrier n1 policy number are: Insurance Co. EVEREST NATIONAL INSURANCE Policy No. 7800000835141 Expiration Date 0110112017 Jlli,section need not be completed if the permft is for one hundred dollcrs ($100) or less. U CertlftCIIa of Exemption: I certify that in the pelformance of the \Wilt for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Wortcers' Compensation Laws of California. WARNING: Failure to 88CUill workenl' c:oqiiiiUIIon COYW'Ifllla uniiWful, and shill 8llbject 111 _.oyer to criminal penaltle~llld c:ivll fin• up to one hundntd lhousand dolllrs (&100,000), in addition to the cost of campenlltion, damage~ a for in Sedlon 3700 oflhe lntarest and lltomey's fe8l. N$ CONTRACTOR SIGNATURE I hereby affltm lhat I em exempt from Conttador's License 1..1111 for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, wiN do the work and the slructure is not irdended or offered for sale {Sec. 7044, lllsiness and Prolessions Code: The Conlraclor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own eml*71ee5, provided that such improvements are not inlended or offered for sale. If, however, the buildi~ or improvement Is sold within one year of completion, the owner-builder will haw the burden of provi~ that he did not build or improve tJr the purpose of sale). 0 I, as owner of the property, am exclusively oontracti~ with licensed ~ to conslruCt the projecl {Sec. 7044, Business and Professions Code: The Conlraclor's License Law does not apply to an owner of property who builds or improves lhereon, and contracls for such projecls with contractor{s) licensed pursuant Ill the Conlraclor's License law). 0 I ;rn exempt under Section Business and Prolessions Code for this reason: 1. I pe!SOflally plan Ill provide the major labor and materials for construcllon of the proposed property improvement. [Jves Do 2. I {haw I haw not) signed an application for a building permft for the proposed \Wilt. 3. I have conlracted with the following person {firm) to provide the proposed construction Qnclude nallle address I phone I ~·license number): 4. I plan to provide portions of the Mllk, but I have hired the following person to coordinale, supervise and provide the major work {include nallle I address I phone I~· license number): 5. I wifl provide some of the work, but I haw contracted {hired) the folkMing pe!SOilS to provide the \Wilt indicaled Onclude name I address I phone I type of work): N$ PROPERTY OWNER SIGNATURE 0AGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is lhe applicant or future blildlng occupant required ~ submit a busl,_ plan, a:ulaly hazadous materia& registration bill or risk m111agement and lft\'llnlion program under Sections 255115, 25533 or 25534 of lhe Presley-Tanner Hazardous SubstlriC8 Al:count At:Kf [] Vas o No Is lhe applicll1l or future blildlng occupant required ~ otuln a pennUom the air pollution conlrol district or air quality management district? [] Vas [] No Is lhe facility 1D be construclad within 1,000 fBel of lhe ouiBr boundary of a school site? [] Vas [] No IF AHY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEEllNG THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTlOH CONTROL DISTRICT. I c811ifythatlhlll8181d .. _....IIIII .-lllll .. ebolle lnlllmallon lsconactllld that the lnbmallon onlheplans Is IICCIIIIIB.I!J1P181D c:oqllywllll al Cllrodnnalllld StiB 1111 ~" IUidi!Wconstructlon. I hereby authorize represenlaiNe of lie City cl Carlslal ben&' upon lie 800ve rnenlilned property br inspecliln puiJlOSI!S. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARtLESS THE CITY a CARLSBAD AGAINST All.liABUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOJENCE a THE GRANTING a THIS PERMIT. OSHA: kl OSHA penni is ~ b' 8IDIYliliMs av« 5'0' deep and demollkln or mnstruction of s1ruclures aver 3 sbias in height EXPIRATION: Evely penTII issued by lie 8iklng <.li:ial under the j:liiWisilns of1hls Code shaD expie by mtalkJn and bealme nul and wil if the buitlilg or \Wik aJilorizBd by such pemil is not amnerml Wllil 100 days tom the dale of such pemil !I' if the buikli1g ormaulhorized is suspended or abandoned at anytime alter them is CXJilWTiel1ald b' a period of 100days (Sectkln 100.4.4 Unibm &iikilQ Code). AS' APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB163426 Type: PME Date _______ Inspection Item ____ _ 09/2912016 43 AirCond/Furnace Set 09/29/2016 43 AirCond/Furnace Set 09/29/2016 49 Final Mechanical 09/29/2016 49 Final Mechanical Thursday, September 29, 2016 Inspector Act JW JW Rl AP Rl AP SCHABER: REPLACE AIC Comments AM PLEASE AM PLEASE Page 1 of 1 • CERTIFICATE OF COMPLIANCE CFlR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 1 of3) Project Name: SCHABER RESIDENCE Date Prepared: 2016-09-02 A. General Information CFlR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CFlR-ALT-02 document for each dwelling unit. 01 Project Name SCHABER RESIDENCE 03 Project Location 2257 BOCA ST. OS CACity Carlsbad 07 Zip Code 92009 09 Climate Zone 7 L__ ---------~ .... ----------- B. Space Conditioning (SC) System Information 01 I 02 I 03 ~ SCSystem SCSystem CFAserved Identification or Location or Area bythisSC Name Served System (ft2) System 1 location 1 3131 I Yes nStallmg a @!1gef"1t containing component? Yes 02 Date Prepared 2016-09-02 04 Building Type Single family 06 Dwelling Unit Name SCHABER RESIDENCE 08 Dwelling Unit Conditioned 3131 Floor Area (ft2) Number of space conditioning 10 (SC) systems in this dwelling 1 unit. ··::4nsta111rfi:hevf:Sf (Itsla~g I E!Jam~~ F~nstalling system more than 40 entirely new entirely new components? feet of ducts? duct system? SC system? Yes No No No 10 Alteration Type Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Sectlon150.2(b)1DIIb) Registration Number: 216-A0327297 A-OOOOOOOD0-0000 CA Building Energy Efficiency Standards -2013 Residential Compliance This section does not apply to this project. Registration Date/Time: 2016-09-02 09:16:33 Report Version: 2013 Rev 1.008 Schema Version: 0.555SOO HERS Provider: CaiCERTS Report Generated: 2016-09-02 09:16:47 -----------.--------~----- CERTIFICATE OF COMPUANCE Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) D. Altered Space Conditioning System (Sections 1S0.2(b)1E and F) 01 1 02 I 03 I 04 System Heating Altered Heating Identification System Heating Effldericy or Name Type Components Type I Central gas No heating This field or System 1 component section is not furnace altered applicable ReQuired oocumentatlon; CF2R-MCH-Q1-E-Space Conditioning Systems Ducts and Fans -Duct Insulation requirement for new plenums: R6. I 05 Heating Minimum Efficiency Value This field or section is not applicable CFlR-ALT-02-E (Page 2 of 3) 06 07 08 09 I 10 I 11 I 12 Cooling Altered Cooling Minimum Required New or Cooling Cooling Effldency Efficiency Thermostat Replaced I New Duct System Type Components Type Value Type Duct Length R-Value Central split Outdoor Less than or condensing SEER 14 Setback equal to40 I R-6 AC unit feet CF2R-MCH-2Q-H & CF3R-MCH-2Q-H-Duct Leakage testing required when heating or cooling components are Installed inducted systems, or when more than 40ft of duct length Is replaced. -Leakage rate compliance: :s; 1S%, or :s; 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge vertficatlon required when refrigerant containing components are Installed or altered (applicable in cz 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air flow i! 300CFM/ton required when MCH-25 is required. Exceptions; E. Entirely New or Complete Replacement Du This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 1S0.2(b)1C) This section does not apply to this project. Registration Number: 216-A0327297 A-000000000-0000 Registration Date/Time: 2016-09-02 09:16:33 CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: O.SSSSDD HERS Provider: CaiCERTS Report Generated: 2016-09-02 09:16:47 CERTIFICATE OF COMPUANCE CF1R-ALT-D2-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 3 of3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Young, Les Documentation Author Signature: ~~~ Company: OAK ISLAND HEATING AND AIR CONDITIONING INC Address: 1250 PACIFIC OAKS PL # 103 City/State/Zip: ESCONDIDO CA 92029 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. • Signature Date: 2016-09-02 09:16:33 CEA/ HERS Certification Identification (if applicable): Phone: 760-839-8383 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design Identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, nufa d~·· e... . for . e .b. u. :!f· .· .. 3··. . . syst·e· m. desfB .... n id. e. nti·f· ied.. on. t. his .. Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part6ofthe California Code of · · ···· · !II! · "" ·· · I; 4. The building design features or system design feat1,1res I ntlfled o ance a . . . . .· · e · · .. rm rovided o t~.,ffifnpllance documents, worksheets, calculations, plans and specifications submitted to he this bui g per a . icatlll. ·. · ~. 5. I will ensure thata registered copy ofthls Certlfi pllance s i le · · · · mit · lssJL fo . . : •· 1l<f(iig, an · a Inspections. I understand that a registered copy of th icate of CoJllpipnc\l.$..req'-9t.e~ to ge,Jncluded 't,h th~cum~tio the)>dli~er p~:~tl_des t~e b , : ing owner at occupancy. Resoonsible Designer Name: , Les Company: OAK ISLAND HEATING AND AIR CONDITIONING INC Address: 1250 PACIFIC OAKS PL # 103 City/State/Zip: ESCONDIDO CA 92029 Date Signed: 2016-09-02 09:16:33 License: 745400 Phone: 760-839-8383 Digitally signed by Cs/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0327297 A-000000000-0000 CA Building Energy Efficiency Standards -2013 Residential Compliance Registration Date/Time: 2016-09-02 09:16:33 Report Version: 2013 Rev 1.008 Schema Version: 0.555SOO HERS Provider: CaiCERTS Report Generated: 2016-09-02 09:16:47 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of7) Project Name: SCHABER RESIDENCE Enforcement Agency: City of Carlsbad Permit Number: on site Dwelling Address: A. General Information 01 03 Dwelling Unit Name Dwelling Unit Total Conditioned Floor Area (ft2) 2257 BOCA ST. SCHABER RESIDENCE 3131 City: 02 04 Carlsbad Zip Code: Climate Zone Number of Space Conditioning Systems in this Dwelling Unit. OS Certificate of Compliance Type Prescriptive alterations (CF1R-ALT ) 06 Method used to Calculate HVAC Loads 07 Calculated Dwelling Unit Sensible Cooling Load (Btuh) This field or section is not applicable 08 calculated Dwelling Unit Heating Load (Btu h) 09 I Dwelling Unit Number of Bedrooms I 4 MCH-Olb Space Conditioning Systems Ducts an B. Space Conditioning (SC) System Information 01 02 03 04 SCSystem SCSystem CFAserved Is the SC Identification or Location or Area bythisSC system a Name Served System (ft2) ducted system? System 1 I Location 1 I 3131 I Yes I Registration Number: 216-A0327297 A-M0100002A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance OS I 06 I 07 I Installing a Installing new SC Installing more refrigerant system than 40 feet of containing components? ducts? component? Yes I Yes I No I Registration Date/Time: 2016-09-20 11:50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 08 Installing entirely new duct system? No 92009 7 1 NotApplicableEquipmentChangeout This field or section is not applicable I 09 I 10 Installing entirely new SCI Alteration Type system? I I Altered space I No I conditioning system HERS Provider: CaiCERTS Report Generated: 2016-09-20 ll:S1:37 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans C. Space Conditioning (SC) System Alterations Compliance Information 01 02 03 04 OS Heating System Altered Heating Minimum Identification Heating Heating Efficiency Efficiency or Name System Type Component Type Value This field No heating or This field System 1 Central gas section is or section furnace componen not is not t altered applicabl applicable e D. Installed Heating Equipment Information E. Installed Cooling Equipment information 01 02 System Identification or Name Cooling Efficiency Type Cooling Efficiency Value System 1 SEER 14 Notes: Registration Number: 216-A0327297A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance 06 07 08 09 Cooling Altered Cooling Minimum Cooling Cooling Efficiency Efficiency System Type Components Type Value All new Central cooling SEER 14 splitAC components 04 OS 06 Condenser or Package Unit Condenser or Package Unit Manufacturer Lennox Condenser or Package Unit Model Number 14acx-060-230- 15 Condenser or Package Unit Serial Number 1916g15150 Registration Date/Time: 2016-09-20 11 :50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 10 11 New or Required Replaced Thermostat Duct Type Length Setback LTE40Ft System Rated Cooling Capacity at Design Conditions (BTUH) 60000 CF2R-MCH-01-E (Page 2 of7) I 12 13 Central Fan I Integrated I (CFI) New Ventilation Duct System I R-Value Status R6 Not a CFI system 08 Condenser Rated Nominal Capacity (ton) 5 HERS Provider: CaiCERTS I I I I Report Generated: 2016-09-20 11:51:37 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans F. Extension of Existing Duct System, Greater Than 40 Feet G. Installed Duct System information H. Installed Air Filter Device Information I. Air Filter Device Requirements Registration Number: 216-A0327297A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance This section does not apply to this project. This section does not apply to this project. This section does not apply to this project. Registration Date/Time: 2016-09-20 11:50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CFZR-MCH-01-E (Page 3 of 7) HERS Provider: CaiCERTS Report Generated: 2016-09-20 11:51:37 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans J. HERS Verification Requirements 01 I oz I 03 I 04 I MCHZO I Exemption System I SCSystem From Duct Duct Identification or Location or Area Leakage Leakage Name Served Requirements Test Altered duct system has System 1 I Locationl I iessthan 40ft I of duct in No I Notes: Registration Number: 216-A0327297A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance OS 06 07 MCHZ1 MCHZZ Exemption from Minimum R-Valuefor Ducts In Ducts Located AHU Fan Conditioned In Cond Space Efficacy Space Verification (W/dm) No I No I No I Exemption Registration Date/Time: 2016-09-20 11 :50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CFZR-MCH-01-E (Page 4of 7) 08 09 10 MCH23 MCHZS MCHZS AHU Airflow Rate Refrigerant I Return Duct Design (dm/ton) Charge Table 150.0-C or D No I No I No • HERS Provider: CaiCERTS Report Generated: 2016-09-20 11:51:37 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 02 03 04 05 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 1SO.O(i), 110.2(b). Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 1SO.O(h)1 and 2). Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature rise specification. See Section 1SO.O(h)4. Standby Losses and Pilot Lights: Fan-type central Cooling Equipment 06 07 08 09 Equipment Efficiency: All cooling equipment Regulations. th«Jmti"E' el'fnsequire,tsf\Se«(~ Htyan1 Se~ 1f~2(ar~d the Appliance Efficiency Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 1SO.O(m)9. Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 1SO.O{h)3A. Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 1SO.O(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 1SO.O{m)1. Registration Number: 216-A0327297A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance Registration Date/Time: 2016-09-20 11:50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-09-20 11:51:37 CERTIFICATE OF INSTALLATION CF2R-MCH-Q1-E Space Conditioning Systems, Ducts, and Fans (Page 6 of7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. 11 Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 I A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 I The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 I First stage of heating shall be assigned to heat pump heating. 15 Second stage back up heating shall be set to come on only when the ind or set temperature cannot be met. Registration Number: 216-A0327297 A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance Registration Date/Time: 2016-09-20 11 :50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 • HERS Provider: CaiCERTS Report Generated: 2016-09-20 11:51:37 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Les Young Company: OAK ISLAND HEATING AND AIR CONDITIONING INC Address: 1250 PACIFIC OAKS PL # 103 City]State/Zip: ESCONDIDO CA 92029 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. Documentation Author Signature: ~ Signature Date: 2016-09-20 11:50:50 CEA/ HERS Certification Identification (if applicable): Phone: 760-839-8383 CF2R-MCH-01-E (Page 7 of7) 2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certifi~te of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. E"'* 8 /'<¥&; 'I The constructed or installed features, materials, components or ufactur @ • e t mstallati · d this rtifi:£·" f lnstallatiico~to j(f,-1icable codes and regulations, and the installation conforms to the requirements given on th ns and o d the enf emen . 1 I reviewed a copy of the Certificate of Complian ' d by the th · ,· 'fie uir en ,pe ofJ>nauctfll ~I 'lion identified on this Certificate of 3. 4. Installation, and I have ensured that the requireme pply to the construction or installation have been met. , I will ensure that a registered copy of this Certificate of lation shfet posW, or l:ae a~ble witnp bu& p~) i¥ forJhe ~g, E ma~fvailable to the enforcement agency for all 5. applicable inspections. I understand that a registered copy o this Certificate oMtalla\io'?i is r'l!(uired to be includtd'l,:;,it~fdocumentation tht"ffuilder provides tb the building owner at occupancy. Responsible Builder/Installer Name: Les Young Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) OAK ISLAND HEATING AND AIR CONDITIONING INC Address: 1250 PACIFIC OAKS PL # 103 City/State/Zip: ESCONDIDO CA 92029 Responsible Builder/Installer Signature:~ Position With Company (Title): MGR CSLB License: 745400 Phone: 760-839-8383 Date Signed: 2016-09-20 11:50:50 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0327297 A-M0100002A-OOOO CA Building Energy Efficiency Standards -2013 Residential Compliance Registration Date/Time: 2016-09-20 11:50:50 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-09-20 11:51:37 -~--~~~~~~----~------~--~------------------------------------------=--====