HomeMy WebLinkAbout2257 BOCA ST; ; CB163426; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plumbing/Mechanical/Electrical (PME) Permit
09-06-2016 Permit No: CB163426
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC#:
Project Title:
Applicant:
2257 BOCA ST CBAD
PME
2163402300
SCHABER: REPLACE AIC
OAK ISLAND HEATING AND AIR
STE 103
1250 PACIFIC OAKS PL
ESCONDIDO CA 92029
760 839-8383
Plumbing Fees
Electrical Fees
Mechanical Fees
Other PME Fees
TOTAL PERMIT FEES
Status:
Lot#: 0 Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Owner:
SCHABER FAMILY TRUST 12-18-03
2257 BOCAST
CARLSBAD CA 92009
ISSUED
09/06/2016
SF
09/06/2016
09/06/2016
$0.00
$0.00
$163.00
$0.00
$163.00
Total Fees: $163.00 Total Payments To Date: $163.00 Balance Due:
Inspector:
FINAL APPROVAL .:; --2.1-11 Date: J. Clearance:
$0.00
NOllCE: Aease ta<e CE thct I!.W(Mll ri ~ ll$d irdudes the "IITpCSitiai' ri fees, dedcai(J'IS, resE!I\IGti(J'IS, a ether ec<DiCJ'lS t'ereliter <DI~
l'l'ferred to as "fees/ea:.ticrs." You l'ava 00 days fran the date !lis perrrit Wl> issued to pt'dest i!TpCSiti01 ri these feeslea:.ticrs. If~ pt'dest tten ~ rrust
fdlo.vthe pt'dest IJOCEl(ires sa forth in GMmrert Code Secti016002)(a), a"d file the pt'dest a"d Mf ether llQ.ired irtam:.ti01 wth the aty ~fa
Jl'O(llSSirg in amdaalWth Ca1sba:l Mridpa Code Secti013.32.!m. Failt.J"etotirrelyfdlo.vthct Jl'OOld.rev.ill ber MfSlb>eq.Jert lega <di01toatta:k,
r'EMew, sa aside, vdd, a anJ trar irrpcsiti01.
You ere~ FI..RiltR NOll A ED ti-el~ rigt to pt'dest the spedfied feeslec<DiCJ'lS IXE) NOT APPLY tow:ter a"d 59M91'a:rredial fees a"d 03pEdty
cl'a"ges. ra plarrirg, :zxrirg. ga::lrg a ether sinilar ~icati01 Jl'O(llSSirg a SIBI'\Ii~ fees in CXJI1Eldia1 wth !lis ~ed. I'I(R IXE) IT APPLY to Mf
~ . Wi . . 'nil . . li . . . . .
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0 ENGINEERING OBUILDING OFIRE 0HEALTH D HAZIIATIAPCD
«~4)\ Building Permit Application Plan Check No. C~ l '=:, ~~~
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value ~ CITY OF Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit CARLSBAD email: building@carlsbadca.gov
www.carlsbadca.gov Date~~~~(.,;, ISWPPP
JOB ADDRESS 2257 BOCA ST.
. SUJJD/SPACI:f/UNir. IAPN -- -
Gl/PROJECT # I LOT# I PH.OSE II r OF UNITS r BEDROOMS #BATHROOMS lll:NIINT BUiiiiiiUll NAME I CONSTR. TYPE I occ. GROUP
DESCRIPTION OF WORK: Include Squ.-Feet of Nl'8ctlld ArN(a}
REMOVE AND REPLACE 1 AJC UNIT,
LIKE FOR LIKE
EXISnNGUSE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE .I AIR CONDmONING II FIRE SPRINKLERS
YES(]t#. N<Q YES0No0 YES0N00
APPLICANT NAME TOM WOOD PROPERTY OWNER NAME CAROLINA SCHABER p
ADDRESS ADDRESS 1250 PACIFIC OAKS PL. #103 2257 BOCA ST.
CllY STATE ZIP CllY STATE ZIP
ESCONDIDO CA 92029 CARLSBAD CA 92009
PHONE I FAX PHONE I FAX 760 839-8383 760 839-8380 760·815·5999
EMAIL EMAIL
INFO@()AKISLANDAC.COM
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME OAK ISLAND HEATING AND AIR
ADDRESS ADDRESS 1250 PACIFIC OAKS PL #103
CllY STATE ZIP CllY STATE ZIP
ESCONDIDO CA 92029
PHONE PHONE I FAX 760 839-8383 I FAX 760 839·8380
EMAIL EMAIL INFO@OAKISLANDAC.COM I STATE LIC. II STATELIC.# IClASSc-20 .lcrrvsus.uc.1212710 745400 .. (Sec. 7031.5 Busrness and Professrons Code: Arry City or County whrch requrres a perrnrt to construct, alter, rmprove, demolrsh or repair all)' structure, pnor to rts rssuanoa, also ~ulres the applicant for such permit to file a siilned statement tftat he is lioansed pursuant to the provisions of the Contractor's UCense Law IChaDter 9, commenc:tirl!f with Section 7000 of DiVision 3 of the Business and Professions Code) or Blat he is exempt; therefrom, and the basis for the alleged exemption. Arry violation of Section 7031.5 by any applicanffor a permit subjects the applicant to a civil penally of not more than fiVe hundred dollars {$500)).
WORI<ERS' COMPENSATION
Workenl' Compenslllon Decllnlllon: I hflreby 8fflnn under PfiiiBIIY of petjuty one of the folk1Mng declsnlllons:
0 I have and wlllllllllnllln a certlflcll8 of consent to lilt-Insure for WQI1(ers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permft is issued.
[l] I have and wlllllllllntlln workers' ~. as teQUir8d bv Section 3700 of the Labor Code. for the performance of the \Wilt for which this permft is Issued. My wokers' compensation insurance carrier n1 policy
number are: Insurance Co. EVEREST NATIONAL INSURANCE Policy No. 7800000835141 Expiration Date 0110112017
Jlli,section need not be completed if the permft is for one hundred dollcrs ($100) or less. U CertlftCIIa of Exemption: I certify that in the pelformance of the \Wilt for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Wortcers' Compensation Laws of
California. WARNING: Failure to 88CUill workenl' c:oqiiiiUIIon COYW'Ifllla uniiWful, and shill 8llbject 111 _.oyer to criminal penaltle~llld c:ivll fin• up to one hundntd lhousand dolllrs (&100,000), in
addition to the cost of campenlltion, damage~ a for in Sedlon 3700 oflhe lntarest and lltomey's fe8l.
N$ CONTRACTOR SIGNATURE
I hereby affltm lhat I em exempt from Conttador's License 1..1111 for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, wiN do the work and the slructure is not irdended or offered for sale {Sec. 7044, lllsiness and Prolessions Code: The Conlraclor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own eml*71ee5, provided that such improvements are not inlended or offered for
sale. If, however, the buildi~ or improvement Is sold within one year of completion, the owner-builder will haw the burden of provi~ that he did not build or improve tJr the purpose of sale). 0 I, as owner of the property, am exclusively oontracti~ with licensed ~ to conslruCt the projecl {Sec. 7044, Business and Professions Code: The Conlraclor's License Law does not apply to an owner of
property who builds or improves lhereon, and contracls for such projecls with contractor{s) licensed pursuant Ill the Conlraclor's License law). 0 I ;rn exempt under Section Business and Prolessions Code for this reason:
1. I pe!SOflally plan Ill provide the major labor and materials for construcllon of the proposed property improvement. [Jves Do
2. I {haw I haw not) signed an application for a building permft for the proposed \Wilt.
3. I have conlracted with the following person {firm) to provide the proposed construction Qnclude nallle address I phone I ~·license number):
4. I plan to provide portions of the Mllk, but I have hired the following person to coordinale, supervise and provide the major work {include nallle I address I phone I~· license number):
5. I wifl provide some of the work, but I haw contracted {hired) the folkMing pe!SOilS to provide the \Wilt indicaled Onclude name I address I phone I type of work):
N$ PROPERTY OWNER SIGNATURE 0AGENT DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is lhe applicant or future blildlng occupant required ~ submit a busl,_ plan, a:ulaly hazadous materia& registration bill or risk m111agement and lft\'llnlion program under Sections 255115, 25533 or 25534 of lhe
Presley-Tanner Hazardous SubstlriC8 Al:count At:Kf [] Vas o No
Is lhe applicll1l or future blildlng occupant required ~ otuln a pennUom the air pollution conlrol district or air quality management district? [] Vas [] No
Is lhe facility 1D be construclad within 1,000 fBel of lhe ouiBr boundary of a school site? [] Vas [] No
IF AHY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEEllNG THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTlOH CONTROL DISTRICT.
I c811ifythatlhlll8181d .. _....IIIII .-lllll .. ebolle lnlllmallon lsconactllld that the lnbmallon onlheplans Is IICCIIIIIB.I!J1P181D c:oqllywllll al Cllrodnnalllld StiB 1111 ~" IUidi!Wconstructlon.
I hereby authorize represenlaiNe of lie City cl Carlslal ben&' upon lie 800ve rnenlilned property br inspecliln puiJlOSI!S. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARtLESS THE CITY a CARLSBAD
AGAINST All.liABUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOJENCE a THE GRANTING a THIS PERMIT.
OSHA: kl OSHA penni is ~ b' 8IDIYliliMs av« 5'0' deep and demollkln or mnstruction of s1ruclures aver 3 sbias in height
EXPIRATION: Evely penTII issued by lie 8iklng <.li:ial under the j:liiWisilns of1hls Code shaD expie by mtalkJn and bealme nul and wil if the buitlilg or \Wik aJilorizBd by such pemil is not amnerml Wllil
100 days tom the dale of such pemil !I' if the buikli1g ormaulhorized is suspended or abandoned at anytime alter them is CXJilWTiel1ald b' a period of 100days (Sectkln 100.4.4 Unibm &iikilQ Code).
AS' APPLICANT'S SIGNATURE DATE
Inspection List
Permit#: CB163426 Type: PME
Date _______ Inspection Item ____ _
09/2912016 43 AirCond/Furnace Set
09/29/2016 43 AirCond/Furnace Set
09/29/2016 49 Final Mechanical
09/29/2016 49 Final Mechanical
Thursday, September 29, 2016
Inspector Act
JW
JW
Rl
AP
Rl
AP
SCHABER: REPLACE AIC
Comments
AM PLEASE
AM PLEASE
Page 1 of 1
•
CERTIFICATE OF COMPLIANCE CFlR-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 1 of3)
Project Name: SCHABER RESIDENCE Date Prepared: 2016-09-02
A. General Information
CFlR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented,
use one CFlR-ALT-02 document for each dwelling unit.
01 Project Name SCHABER RESIDENCE
03 Project Location 2257 BOCA ST.
OS CACity Carlsbad
07 Zip Code 92009
09 Climate Zone 7
L__ ---------~ .... -----------
B. Space Conditioning (SC) System Information
01 I 02 I 03
~
SCSystem SCSystem CFAserved
Identification or Location or Area bythisSC
Name Served System (ft2)
System 1 location 1 3131 I Yes
nStallmg a
@!1gef"1t
containing
component?
Yes
02 Date Prepared 2016-09-02
04 Building Type Single family
06 Dwelling Unit Name SCHABER RESIDENCE
08 Dwelling Unit Conditioned 3131 Floor Area (ft2)
Number of space conditioning
10 (SC) systems in this dwelling 1
unit.
··::4nsta111rfi:hevf:Sf (Itsla~g I E!Jam~~ F~nstalling
system more than 40 entirely new entirely new
components? feet of ducts? duct system? SC system?
Yes No No No
10
Alteration Type
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Sectlon150.2(b)1DIIb)
Registration Number: 216-A0327297 A-OOOOOOOD0-0000
CA Building Energy Efficiency Standards -2013 Residential Compliance
This section does not apply to this project.
Registration Date/Time: 2016-09-02 09:16:33
Report Version: 2013 Rev 1.008
Schema Version: 0.555SOO
HERS Provider: CaiCERTS
Report Generated: 2016-09-02 09:16:47
-----------.--------~-----
CERTIFICATE OF COMPUANCE
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
D. Altered Space Conditioning System (Sections 1S0.2(b)1E and F)
01 1 02 I 03 I 04
System Heating Altered Heating
Identification System Heating Effldericy
or Name Type Components Type
I Central gas No heating This field or
System 1 component section is not furnace altered applicable
ReQuired oocumentatlon;
CF2R-MCH-Q1-E-Space Conditioning Systems Ducts and Fans
-Duct Insulation requirement for new plenums: R6.
I 05
Heating
Minimum
Efficiency
Value
This field or
section is not
applicable
CFlR-ALT-02-E
(Page 2 of 3)
06 07 08 09 I 10 I 11 I 12
Cooling
Altered Cooling Minimum Required New or
Cooling Cooling Effldency Efficiency Thermostat Replaced I New Duct
System Type Components Type Value Type Duct Length R-Value
Central split Outdoor Less than or
condensing SEER 14 Setback equal to40 I R-6 AC unit feet
CF2R-MCH-2Q-H & CF3R-MCH-2Q-H-Duct Leakage testing required when heating or cooling components are Installed inducted systems, or when more than 40ft of duct length Is replaced.
-Leakage rate compliance: :s; 1S%, or :s; 10% leakage to outside, or seal all accessible leaks.
CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge vertficatlon required when refrigerant containing components are Installed or altered (applicable in cz 2, 8-15).
CF2RCF3R-MCH-23 & CF3R-MCH-23 Air flow i! 300CFM/ton required when MCH-25 is required.
Exceptions;
E. Entirely New or Complete Replacement Du
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 1S0.2(b)1C)
This section does not apply to this project.
Registration Number: 216-A0327297 A-000000000-0000 Registration Date/Time: 2016-09-02 09:16:33
CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.008
Schema Version: O.SSSSDD
HERS Provider: CaiCERTS
Report Generated: 2016-09-02 09:16:47
CERTIFICATE OF COMPUANCE CF1R-ALT-D2-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 3 of3)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Young, Les
Documentation Author Signature: ~~~
Company:
OAK ISLAND HEATING AND AIR CONDITIONING INC
Address:
1250 PACIFIC OAKS PL # 103
City/State/Zip:
ESCONDIDO CA 92029
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
• Signature Date:
2016-09-02 09:16:33
CEA/ HERS Certification Identification (if applicable):
Phone:
760-839-8383
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design Identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, nufa d~·· e... . for . e .b. u. :!f· .· .. 3··. . . syst·e· m. desfB .... n id. e. nti·f· ied.. on. t. his .. Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part6ofthe California Code of · · ···· · !II! · "" ·· · I;
4. The building design features or system design feat1,1res I ntlfled o ance a . . . . .· · e · · .. rm rovided o t~.,ffifnpllance documents, worksheets,
calculations, plans and specifications submitted to he this bui g per a . icatlll. ·. · ~.
5. I will ensure thata registered copy ofthls Certlfi pllance s i le · · · · mit · lssJL fo . . : •· 1l<f(iig, an · a
Inspections. I understand that a registered copy of th icate of CoJllpipnc\l.$..req'-9t.e~ to ge,Jncluded 't,h th~cum~tio the)>dli~er p~:~tl_des t~e b , : ing owner at occupancy.
Resoonsible Designer Name:
, Les
Company:
OAK ISLAND HEATING AND AIR CONDITIONING INC
Address:
1250 PACIFIC OAKS PL # 103
City/State/Zip:
ESCONDIDO CA 92029
Date Signed:
2016-09-02 09:16:33
License:
745400
Phone:
760-839-8383
Digitally signed by Cs/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 216-A0327297 A-000000000-0000
CA Building Energy Efficiency Standards -2013 Residential Compliance
Registration Date/Time: 2016-09-02 09:16:33
Report Version: 2013 Rev 1.008
Schema Version: 0.555SOO
HERS Provider: CaiCERTS
Report Generated: 2016-09-02 09:16:47
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 1 of7)
Project Name: SCHABER RESIDENCE Enforcement Agency: City of Carlsbad Permit Number: on site
Dwelling Address:
A. General Information
01
03
Dwelling Unit Name
Dwelling Unit Total Conditioned Floor
Area (ft2)
2257 BOCA ST.
SCHABER RESIDENCE
3131
City:
02
04
Carlsbad Zip Code:
Climate Zone
Number of Space Conditioning
Systems in this Dwelling Unit.
OS Certificate of Compliance Type Prescriptive alterations (CF1R-ALT ) 06 Method used to Calculate HVAC Loads
07 Calculated Dwelling Unit Sensible
Cooling Load (Btuh) This field or section is not applicable 08 calculated Dwelling Unit Heating Load
(Btu h)
09 I Dwelling Unit Number of Bedrooms I 4
MCH-Olb Space Conditioning Systems Ducts an
B. Space Conditioning (SC) System Information
01 02 03 04
SCSystem SCSystem CFAserved Is the SC
Identification or Location or Area bythisSC system a
Name Served System (ft2)
ducted
system?
System 1 I Location 1 I 3131 I Yes I
Registration Number: 216-A0327297 A-M0100002A-0000
CA Building Energy Efficiency Standards-2013 Residential Compliance
OS I 06 I 07 I
Installing a Installing new SC Installing more refrigerant system than 40 feet of containing components? ducts? component?
Yes I Yes I No I
Registration Date/Time: 2016-09-20 11:50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
08
Installing
entirely new
duct system?
No
92009
7
1
NotApplicableEquipmentChangeout
This field or section is not applicable
I 09 I 10
Installing
entirely new SCI Alteration Type
system?
I
I
Altered space
I No I conditioning
system
HERS Provider: CaiCERTS
Report Generated: 2016-09-20 ll:S1:37
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
C. Space Conditioning (SC) System Alterations Compliance Information
01 02 03 04 OS
Heating
System Altered Heating Minimum
Identification Heating Heating Efficiency Efficiency
or Name System Type Component Type Value
This field
No heating or This field
System 1 Central gas section is or section
furnace componen not is not t altered applicabl applicable
e
D. Installed Heating Equipment Information
E. Installed Cooling Equipment information
01 02
System Identification
or Name
Cooling Efficiency
Type
Cooling Efficiency
Value
System 1 SEER 14
Notes:
Registration Number: 216-A0327297A-M0100002A-OOOO
CA Building Energy Efficiency Standards -2013 Residential Compliance
06 07 08 09
Cooling
Altered Cooling Minimum
Cooling Cooling Efficiency Efficiency
System Type Components Type Value
All new Central cooling SEER 14 splitAC components
04 OS 06
Condenser or Package Unit
Condenser or
Package Unit
Manufacturer
Lennox
Condenser or
Package Unit
Model Number
14acx-060-230-
15
Condenser or
Package Unit
Serial Number
1916g15150
Registration Date/Time: 2016-09-20 11 :50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
10 11
New or
Required Replaced
Thermostat Duct
Type Length
Setback LTE40Ft
System Rated Cooling
Capacity at Design
Conditions (BTUH)
60000
CF2R-MCH-01-E
(Page 2 of7)
I
12 13
Central Fan I
Integrated I
(CFI)
New Ventilation
Duct System I
R-Value Status
R6 Not a CFI
system
08
Condenser Rated
Nominal Capacity
(ton)
5
HERS Provider: CaiCERTS
I
I
I
I
Report Generated: 2016-09-20 11:51:37
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
F. Extension of Existing Duct System, Greater Than 40 Feet
G. Installed Duct System information
H. Installed Air Filter Device Information
I. Air Filter Device Requirements
Registration Number: 216-A0327297A-M0100002A-OOOO
CA Building Energy Efficiency Standards -2013 Residential Compliance
This section does not apply to this project.
This section does not apply to this project.
This section does not apply to this project.
Registration Date/Time: 2016-09-20 11:50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
CFZR-MCH-01-E
(Page 3 of 7)
HERS Provider: CaiCERTS
Report Generated: 2016-09-20 11:51:37
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
J. HERS Verification Requirements
01 I oz I 03 I 04 I
MCHZO I
Exemption
System
I
SCSystem From Duct Duct
Identification or Location or Area Leakage Leakage
Name Served Requirements Test
Altered duct
system has
System 1 I Locationl I iessthan 40ft I
of duct in No I
Notes:
Registration Number: 216-A0327297A-M0100002A-OOOO
CA Building Energy Efficiency Standards -2013 Residential Compliance
OS 06 07
MCHZ1 MCHZZ
Exemption
from
Minimum
R-Valuefor
Ducts In Ducts Located AHU Fan
Conditioned In Cond Space Efficacy
Space Verification (W/dm)
No I No I No I Exemption
Registration Date/Time: 2016-09-20 11 :50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
CFZR-MCH-01-E
(Page 4of 7)
08 09 10
MCH23 MCHZS MCHZS
AHU
Airflow
Rate Refrigerant I Return Duct Design
(dm/ton) Charge Table 150.0-C or D
No I No I No
•
HERS Provider: CaiCERTS
Report Generated: 2016-09-20 11:51:37
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01
02
03
04
05
Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
to program the temperature set points for at least four different periods in 24 hours. See Sections 1SO.O(i), 110.2(b).
Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections
1SO.O(h)1 and 2).
Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum
inlet-to-outlet temperature rise specification. See Section 1SO.O(h)4.
Standby Losses and Pilot Lights: Fan-type central
Cooling Equipment
06
07
08
09
Equipment Efficiency: All cooling equipment
Regulations.
th«Jmti"E' el'fnsequire,tsf\Se«(~ Htyan1 Se~ 1f~2(ar~d the Appliance Efficiency
Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section
150.0(j)2 and 3, and Section 1SO.O(m)9.
Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 1SO.O{h)3A.
Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section
1SO.O(h)1 and 2.
Air Distribution System Ducts, Plenums and Fans
10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
required by the prescriptive or performance requirements. See Section 1SO.O{m)1.
Registration Number: 216-A0327297A-M0100002A-OOOO
CA Building Energy Efficiency Standards -2013 Residential Compliance
Registration Date/Time: 2016-09-20 11:50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
HERS Provider: CaiCERTS
Report Generated: 2016-09-20 11:51:37
CERTIFICATE OF INSTALLATION CF2R-MCH-Q1-E
Space Conditioning Systems, Ducts, and Fans (Page 6 of7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
11
Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
12 I A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
13 I The thermostat shall be installed in accordance with the manufacturers published installation specifications
14 I First stage of heating shall be assigned to heat pump heating.
15 Second stage back up heating shall be set to come on only when the ind or set temperature cannot be met.
Registration Number: 216-A0327297 A-M0100002A-OOOO
CA Building Energy Efficiency Standards -2013 Residential Compliance
Registration Date/Time: 2016-09-20 11 :50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
•
HERS Provider: CaiCERTS
Report Generated: 2016-09-20 11:51:37
CERTIFICATE OF INSTALLATION
Space Conditioning Systems, Ducts, and Fans
Documentation Author's Declaration Statement
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Les Young
Company:
OAK ISLAND HEATING AND AIR CONDITIONING INC
Address:
1250 PACIFIC OAKS PL # 103
City]State/Zip:
ESCONDIDO CA 92029
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
Documentation Author Signature: ~
Signature Date:
2016-09-20 11:50:50
CEA/ HERS Certification Identification (if applicable):
Phone:
760-839-8383
CF2R-MCH-01-E
(Page 7 of7)
2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this Certifi~te of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an
authorized representative of the responsible builder/installer. E"'* 8 /'<¥&; 'I
The constructed or installed features, materials, components or ufactur @ • e t mstallati · d this rtifi:£·" f lnstallatiico~to j(f,-1icable codes and regulations, and the
installation conforms to the requirements given on th ns and o d the enf emen . 1
I reviewed a copy of the Certificate of Complian ' d by the th · ,· 'fie uir en ,pe ofJ>nauctfll ~I 'lion identified on this Certificate of
3.
4.
Installation, and I have ensured that the requireme pply to the construction or installation have been met. ,
I will ensure that a registered copy of this Certificate of lation shfet posW, or l:ae a~ble witnp bu& p~) i¥ forJhe ~g, E ma~fvailable to the enforcement agency for all 5.
applicable inspections. I understand that a registered copy o this Certificate oMtalla\io'?i is r'l!(uired to be includtd'l,:;,it~fdocumentation tht"ffuilder provides tb the building owner at occupancy.
Responsible Builder/Installer Name:
Les Young
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
OAK ISLAND HEATING AND AIR CONDITIONING INC
Address:
1250 PACIFIC OAKS PL # 103
City/State/Zip:
ESCONDIDO CA 92029
Responsible Builder/Installer Signature:~
Position With Company (Title):
MGR
CSLB License:
745400
Phone:
760-839-8383
Date Signed:
2016-09-20 11:50:50
Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 216-A0327297 A-M0100002A-OOOO
CA Building Energy Efficiency Standards -2013 Residential Compliance
Registration Date/Time: 2016-09-20 11:50:50
Report Version: 2013 Rev 1.008
Schema Version: 2013.1.008
HERS Provider: CaiCERTS
Report Generated: 2016-09-20 11:51:37
-~--~~~~~~----~------~--~------------------------------------------=--====