HomeMy WebLinkAbout2257 LEVANTE ST; ; CB162410; Permit (2)City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-02-2016 Residential Permit Permit No: CB162410
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
2257 LEVANTE ST CBAD
RESDNTL Sub Type: RAD
Lot#: 0
Constuction Type: 5B
Reference #:
Status: ISSUED
Applied: 06/20/2016
Entered By: JMA
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Applicant:
DANIEL DOYLE
2162404801
$8,736.00
0
0
JOHNSON: 240 SF SHED
966 CIMARRON TER
ESCONDIDO CA 92029-5724
760-703-3020
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
Structure Type:
Plan Approved: 08/02/2016
Issued: 08/02/2016
Bathrooms: 0
Orig PC#:
Inspect Area:
Plan Check #:
$105.72
$0.00
$74.00
$0.00
$0.00
$1.14
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
$0.00
Owner:
JOHNSON TIMOTHY M&DENISE R
2257 LEV ANTE ST
CARLSBAD CA 92009
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$46.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$227.86
Total Fees: $227.86 Total Payments to Date: $227.86 Balance Due: $0,00
Inspector: ~ Date: Clearance:
t\OllCE Rease take t\OllCE that app-tMli ci IOO' prtject ird.-tte "I · ion" ci 1-. dedcaticn;, reseivaticns, or ctt-er ~cns t-ereafter ooledivay
referred to as 1eeslexacticns." Yru have 00 ~ frcrn tte date tlis p,rrrit v.as issu,d to prctest irrp,;ilion ci trese feesl~ons If )00 prctest then\ )00 rru;t
fdlo.vtt-e prctest proarlres set forth in GoJerm-ent Cale Section !iOOZJ(a), ard filett-e prctest and any ctrer reqjred irtooralionv.ith tte Qty ~for
p-ooessrg in a:x:orda=v.ith Ca1sba:J Mridpal Cale Section 3.32.030. FailuetolrrayftjlONtl-at proceduev.ill bar any ,w;eq..e1 legal edionto atla'.:ls
revi6'N, set aside, 'vcid, or clTU their irllX)Sitioo.
Yru ,re t-eret,,, FLRTI-ER t\OllFIEDthal )l'.JU'riltit to prctest tte specified fees/exactions DOES NOT APA. Ytov.ater ard"""' oonnedion feesard ~
ctmges, ra plmrg, ,mrg, g-adrg or ctt-er srrila-appicalion p-ooessrg or SOIVioe fees in connection v.ith tlis prtject. !\OR DOES IT APA. Y to any
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-02-2016
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW160290
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
DANIEL DOYLE
760-703-3020
Emergency Contact:
TIMOTHY JOHNSON
760 613-1327
2257 LEV ANTE ST CBAD
SWPPP
2162404801
CB162410
JOHNSON: 240 SF SHED
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 0 Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
JOHNSON TIMOTHY M&DENISE R
2257 LEV ANTE ST
CARLSBAD CA 92009
ISSUED
06/20/2016
JMA
08/02/2016
1
L
$49.00
$59.00
$0.00
$108.00
Total Fees: $108.00 Total Payments To Date: $108.00 Balance Due:
FINAL APPROVAL
DATE.LEARAHCE. __ _
SIGNATURE~
$0.00
..
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING 0 ENGINEERING □BUILDING □FIRE □HEALTH 0 HAZMAT/APCD
I?'" (__ City of
Carlsbad
JOB ADDRESS . .Q_J'S,
CT/PROJECT# LOT#
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITEI/SPACEt/UNITI
Plan Check No,
Est. Value
Plan Ck. Deposit
APN
PHASE# # BEDROOMS # BATHROOMS TENANT BUSINESS NAME
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
12. I )( ~ 0 / -s\-\ I:; h
ID
SWPPP
-()4 -o
CONSTR. TYPE OCC. GROUP
RE:5
EXISTING USE GARAGE (SF} PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
YES(J# No!Z] YES □NOIZJ YES□N0.12']
PROPERTY OWNER
ADDRESS
CITY q CITY ZIP
PHONE PHON
EMAIL
CONTRACTOR BUS. NAME
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL ,(Orv\
ST&,?iot) STATE UC.# CLASS CITY BUS. UC.#
(Sec. 7031.5 Business and Professions Code: Any City or Coun_ty which requires a permit to.construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the prov1s1ons of the Contractor's License Law /Chapter 9, commending with Section 70_00 of Division 3 of the Business and Professions Code} or that he 1s exempt therefrom, and the basis for the alleged exemption. Any violation of Section 1031.5 by any applicant for a permit subiects the applicant to a
civil penalty of not more than five hundred dollars {$500)).
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of p&jury one of the following declarations: D I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and IX)lk:y
number are: Insurance Co ______________________ Policy No. _______________ Expiration Date _________ _
~section need not be completed if the permit is for one hundred dollars ($100) or less. LJ Certificate of Ex.emption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, interest and attorney's fees.
,8$ CONTRACTOR SIGNATURE DATE
OWNER~BUILDER DECLARATION
/ here affirm that I am exempt from Contractor's Ucense Law for the fol/owmg reason
□
□
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am ex.elusively contracting with licensed contractors to construct the proj8Ct (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section _____ ,Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. OYes ONo
2. I (have I have not) signed an application for a building permit for the pro!X)sed work
3. I have contracted with the following person (firm) to provide the pro!X)sed construction {include name address/ phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number)·
hired) the following persons to provide the work indicated (include name I address/ phone/ type of work):
65 PROPERTY OWNER SIGNATURE □AGENT
COMPLETE THIS SECTION FOR NON•RESIDENTIAL BUILDING PERMITS ONLY
1.$ the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Acr □ Yes □ No
Is the applicant or future building occupant required lo obtain a permit from the air pollution control district or air quality management dis trier □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency fOf the peiformance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above infonnation is oonectand that the infunnation on the plans is accurate. I agree ID oomply'Mth all City ordinances and State laws relating ID building oonstruction.
I hereby authorize representative of the City of Ca~sbad to enter u~n the atove mentioned ~rty br inspection purp:ises. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
' AGAINST ALL LIABILmEs, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CDNSEOJENCE OF THE GRANTING OF THIS PERMIT.
I OSHA: M OSHA pennt is requred forexc:all8Hons over 5'0' deep and demdition or construction of sln.lctures over 3 stories in he'Jhl.
EXPIRATION: E11ery i;enntt issued by !he Buik:1ing Offi::ial under ltie provisKlns of ltiis Code shall expire by limitaOOn and tro:Jme null and 'IOd Wlhe buik:!KlQ or oorl< authcxized by sud1 permit IS ootcommenced 'Nilhin
100days tram ltie date of suet, i:errnij or iflhe.buik:f authorized bv r;ermt is suspended or abandoned at any time after the~ is commence::! tir a~ -100 days (Secfun 100.4.4 UnOOrm Building Code)
.A$ APPLICANT'S SIGNATURE DATE
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602•8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE
Carlsbad CA
PHONE FAX
EMAIL______ OCCUPANT'S BUS. LIC. No.
DELNERY OPTIONS
□ PICK UP: CONTACT (listed above) i:..: OCCUPANT (listed above)
c: CONTRACTOR (On Pg. 1)
□ MAIL TO: o CONTACT (Listed above) c-: OCCUPANT (Listed above)
~ CONTRACTOR (On Pg. 1)
□MAIL/FAX TO OTHER: _______________ _
A$ APPLICANT'S SIGNATURE
□ ASSOCIATED CB#-------------
0 NO CHANGE IN USE/ NO CONSTRUCTION
o CHANGE OF USE/ NO CONSTRUCTION
DATE
ZIP
PERMIT INSPECTION HISTORY REPORT (CB162410)
Pc'rmit Type: BLDG-Residential Application Dato: 06/20/2016 Owner:
Work Class: Addition Issue Date: 08/02/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 08/07/2017 Address:
IVR Number: 715322
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
05/03/2017 05/03/2017
05/08/2017 0Sf08l2017
May 08, 2017
BLDG-Final
Inspection
BLDG-Final
Inspection
Checklist Item
BLDG-Structural Final
BLOG-Electrical Final
022047-2017
Checklist Item
BLDG-Structural Final
BLDG-Electrical Final
022642-2017
Checklist Item
BLDG-Structural Final
BLDG~Electrical Final
COMMENTS
Uncover east side underfloor vent
GFCI not working due to bad ground
Failed Andy Krogh
COMMENTS
GFCI not working due to bad ground, 5/3/17
ground corrected but partial outlets not
GFCI protected
Passed Andy Krogh
COMMENTS
COOWNER TIMOTHY AND DENISE
JOHNSON
2257 Levante St
Carlsbad, CA 92009
Reinspection
Passed
No
No
Relnspection
Passed
Yes
No
Passed
Yes
Yes
Complete
Complete
Complete
Page 2 of 2
PERMIT INSPECTION HISTORY REPORT (CB162410)
Permit Type: BLDG-Residential Application Date: 06/20/2016 Owner: COOWNER TIMOTHY AND DENISE
JOHNSON
Work Class: Addition Issue Date: 08/02/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 08/07/2017 Address: 2257 Levante St
Carlsbad, CA 92009
IVR Number: 715322
Scheduled Actual Inspection Type Inspection No. Inspection Status Re inspection Complete Date Start Date Primary Inspector
11/16/2016 11/16/2016 BLDG-14 001384-2016 Failed Andy Krogh Reinspection Complete
FramefSteel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Install shear walls per install guide and No
finish exterior nailing
BLDG-31 001611-2016 Passed Andy Krogh Complete
Underground/Condu
it-Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/29/2016 11/29/2016 BLDG-13 Shear 003478-2016 Passed Andy Krogh Complete
Panels/HD (ok to
wrap)
12/06/2016 12/06/2016 BLOG-34 Rough 004345-2016 Passed Andy Krogh Complete
Electrical
12/1312016 12/13/2016 BLDG-17 Interior 005260-2016 Failed Andy Krogh Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No answer/ no one home No
12/1612016 12/16/2016 BLDG-82 Drywall, 006110-2016 Passed Andy Krogh Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
NOTES Created By TEXT Created Date
Andy Krogh Exterior lath & drywall 12/16/2016
04/28/2017 0412812017 BLDG-Final 021557-2017 Failed Mlchael Collins Reinspection Complete
Inspection
Checklist !tom COMMENTS Passed
BLDG-Building Deficiency See card for corrections. No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLOG-Electrical Final No
0510212017 0510212017 BLDG-Final 021803-2017 Failed Andy Krogh Reinspection Complete
Inspection
May 08, 2017 Page 1 of 2
Inspection History:
09/13/2016: 11-BLDG-Ftg/Foundation/Piers Approval Completed By AEK;
10/03/2016: 14-BLDG-Frame/Steel/Bolting/Welding Approval Completed By MC SUB-FLOOR
FRAME/MECHANICAL CONNECTORS.;
10/18/2016: 15-BLDG-Roof/Reroof Approval Completed By AEK;
09/26/2016: 66-BLDG-Grout Approval Completed By AEK
DATE: July 15, 2016
JURISDICTION: Carlsbad
PLAN CHECK NO.: 16-2410
EsGil Corporation
In <Partnersnip witn tjo'fJernment for 1/Jui(aing Safety
SET: II
PROJECT ADDRESS: 2257 Levante Street
PROJECT NAME: Storage Shed for Timothy & Denise Johnson
□ APPLICANT
;d JURIS.
□ PLAN REVIEWER
□ FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: -
Date contacted: -(by:.J/c)
Mail Telephone Fax In Person
0 REMARKS:
By: Abe Doliente
EsGil Corporation
0 GA O EJ O MB O PC
Telephone#:
Email:
Enclosures:
7/11/16
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: June 24, 2016
JURISDICTION: Carlsbad
PLAN CHECK NO.: 16-2410
EsGil Corporation
In <Partnersfiip witfi qo..,ernment for <BuiWing Safety
SETI
PROJECT ADDRESS: 2257 Levante Street
PROJECT NAME: Storage Shed for Timothy & Denise Johnson
□ PLICANT
JURIS.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
ISi The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
ISi The applicant's copy of the check list has been sent to:
Daniel Doyle
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
ISi EsGil Corporation staff did advise the applicant that the plan check has been completed.
□
Person contacted: Daniel D~oyle
Date contacted: ~ -2..'f(b : )
Q,, Mail)( Telephone ~"' Fax In erson
REMARKS:
By: Abe Doliente
EsGil Corporation
0 GA O EJ O MB O PC
Telephone#: 760-703-3020
Email: danieldoyle@hotmail.com
Enclosures:
6/21/16
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 16-2410
June 24, 2016
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 16-2410 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2257 Levante Street
FLOOR AREA: Storage Shed = 240 SF STORIES: 1
HEIGHT:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: June 24, 2016
FOREWORD (PLEASE READ):
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 6/21/16
PLAN REVIEWER: Abe Doliente
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list {or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 16-2410
June 24, 2016
Please make all corrections, as requested in the correction list. Submit THREE
sets of plans for residential projects. For expeditious processing, corrected sets
can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring rtiQ corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
• PLANS
1. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code). This will be verified
before the plans are approved.
2. Provide structural calculations and construction details of all masonry walls.
Include the size, location and spacing of the reinforcements, size of the footing
and the required reinforcements. Sections R606 and R611.
3. Provide structural calculations and construction details of all masonry retaining
walls. Include the height of the retained soil, size, location and spacing of the
reinforcements, size of the footing and the required reinforcements. Section
R404.
4. Plate washers conforming to Section R602.11.1, 0.229"x3"x3", shall be
provided for all anchor bolts over the full length of required braced wall lines.
Properly sized cut washer shall be permitted for anchor bolts in wall lines not
containing braced wall panels.
5. Show stud spacing on the plans. Maximum allowable stud heights shall be per
Table R602.3(5).
6. The conventional framing provisions cannot be used if the bearing stud wall
height exceeds 1 0 feet, per Table R602.3(5).
7. Specify floor joist spacing.
Carlsbad 16-2410
June 24, 2016
• To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Abe Doliente at EsGil Corporation. Thank
you.
·carlsbad 16-2410
June 24, 2016
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Abe Doliente
PLAN CHECK NO.: 16-2410
DATE: June 24, 2016
BUILDING ADDRESS: 2257 Levante Street
BUILDING OCCUPANCY: U
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Storaae shed 240 25.78
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee by Ordinance I • j
Plan Check Fee by Ordinance I .., I
Type of Review: 0 Complete Review
Reg. VALUE
Mod.
D Structural Only
D Repetitive Fee
[.:] Repeats
D Other
D Hourly
EsGII Fee
1-------11 Hr. @ •
Comments:
($)
6,187
6,187
$87.981
$57.191
$49.27J
Sheet 1 of 1
macvalue.doc +
• .
PLAN CHECK
REVIEW
TRAN SM ITT AL
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
DATE: 07/05/2016 PROJECT NAME: JOHNSON RESIDENTIAL SHED PROJECT ID:CB162410
APN: 2162404801 PLAN CHECK NO: 1
VALUATION: $8,736
SET#: 1 ADDRESS: 2257 LEVANTE ST
SCOPE OF WORK: 12 X 20 SHED
This plan check review is complete and has been APPROVED by:
LAND DEVELOPMENT ENGINEERING DIVISION
Final Inspection by Construction Management & Inspection Division is required: Yes No X
□ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: DANIELDOYLE@HOTMAIL.COM
To determine status by one of the divisions listed below, please contact 76()..602-2719.
760-602-4624
Chris.Sexton@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Remarks:
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
ValRay Nelson
760-602-27 41
ValRay.Marshall@carlsbadca.gov
Gregory. Rya n@ca rlsbadca .gov
Cindy Wong
760-602-4662
Cynthia.Wong@carlsbadca.gov
Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
JOHNSON RESIDENTIAL SHED PLAN CHECK NO# 1
Please Read
Instructions:
Outstanding issues are marked with X Items that conform to permit
requirements are marked with ✓ or have intentionally been left blank.
NO CITY
OWNED
EASEMENTS
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale. Show:
North arrow
Existing & proposed structures
Existing street improvements
Property lines (show all dimensions)
Easements
Right-of-way width & adjacent streets
Show on site plan:
~I Driveway widths
Existing or proposed sewer lateral
Existing or proposed water service
Submit on signed approved plans:
DWG No.
Drainage patterns and proposed site elevations. Show all high points.
Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
Existing & proposed slopes and topography
] Size, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
Site address
Assessor's parcel number
Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.: PAR 1 MAP 14052
Subdivision/Tract:
Reference No(s):
E-36 Page2of6 REV 6/01/12
JOHNSON RESIDENTIAL SHED PLAN CHECK NO# 1
N/A
N/A
N/A
2. DISCRETIONARY APPROVAL COMPLIANCE
Project does not comply with the following engineering conditions of approval for project no.:
3. DEDICATION REQUIREMENTS
Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 24 000 00 , pursuant to Carlsbad Municipal Code Section 18.40.030.
Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS
All needed public improvements upon and adjacent to the building site must be constructed
at time of building construction whenever the value of the construction exceeds
$120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee, so we may prepare the necessary Neighborhood
Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit.
Future public improvements required as follows:
Page 3 of 6 REV 6/01/12
JOHNSON RESIDENTIAL SHED PLAN CHECK NO# 1
NO
E-36
5. GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
[ _] Inadequate information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector The inspector will then
provide the engineering counter with a release for the building permit.
No grading permit required.
Minor Grading Permit required. See additional comments for project-specific requirements.
6. MISCELLANEOUS PERMITS
[_[] RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work
adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
Right-of-way permit required for:
*ANY WORK BEING DONE WITHIN THE PUBLIC RIGHT OF WAY*
Page 4 of6 REV 6/01/12
JOHNSON RESIDENTIAL SHED PLAN CHECK NO# 1
N/A
N/A
E-36
7. STORM WATER
Construction Compliance
Project Threat Assessment Form complete.
Enclosed Project Threat Assessment Form incomplete.
Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form
and return (SW )
Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Development (SUSMPl Compliance
Storm Water Standards Questionnaire.
Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
Indicate areas of impervious surfaces (patios,walkway, etc. ) and pervious areas (landscaping).
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
Bio-retentions cell/rain garden
Pervious pavement/pavers
Flow-through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
Other:
Page 5 of 6 REV 6/01/12
JOHNSON RESIDENTIAL SHED PLAN CHECK NO# 1
N/A
Attachments:
E-36
8. WATER METER REVIEW
Domestic (potable) Use
9. FEES
What size meter is required?
Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be¾".
Required fees have been entered in building permit.
Drainage fee applicable
Added square feet
Added square footage in last two years?
Permit No.
Permit No.
Project built after 1980
Impervious surface> 50%
Impact unconstructed facility
yes
yes
yes
yes
no
Fire sprinklers required
Upgrade
No fees required
::Jyes ! Jno (is addition over 150' from center line)
yes []no
10. ADDITIONAL COMMENTS
Engineering AppllcaUon Storm Water Form Right-of-Way Application/Info. Reference Documents
Page6of6 REV 6/01/12
*** Fee Calculation Worksheet ***
ENGINEERING DIVISION
Prepared by: Date: GEO DATA: LFMZ: / B&T:
Address: Bldg. Permit#:
Fees Update by: Date: Fees Update by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use:
Types of Use:
Types of Use:
Sq.Ft./Units
Sq.Ft./Units
Sq.Ft./Units
Types of Use: Sq.Ft./Units
ADT CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq.Ft./Units
Types of Use:
Types of Use:
Types of Use:
FEES REQUIRED:
Sq.Ft./Units
Sq.Ft./Units
Sq.Ft./Units
EDU's:
EDU's:
EDU's:
EDU's:
ADT's:
ADT's:
ADT's:
ADT's:
Within CFD:[ ;YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) 1/i NO
1. PARK-IN-LIEU FEE: []NW QUADRANT NE QUADRANT LJSE QUADRANT []W QUADRANT
ADT'S/UNITS: I X FEE/ADT: I =$
2.TRAFFIC IMPACT FEE:
ADT'S/UNITS: I X FEE/ADT:
3. BRIDGE & THOROUGHFARE FEE: DIST. #1
(USE SANDAG)ADT'S/UNITS I X FEE/ADT
4. FACILITIES MANAGEMENT FEE ZONE:
I=$
.::DIST.#2
I=$
ADT'S/UNITS: I X FEE/SQ.FT./UNIT: I =$
5. SEWER FEE
EDU's
BENEFIT AREA:
EDU's
6. DRAINAGE FEES:
ACRES:
7. POTABLE WATER FEES:
I X FEE/EDU:
IX FEE/EDU:
PLDA: ! ;HIGH
IX FEE/AC:
I =s
I=$
MEDIUM
I =s
!LOW
UNITS CODE CONN. FEE METER FEE SDCWA FEE
•**This may not represent a comprehensive list of fees due for this project.
DIST.#3
TOTAL
Please contact the Building division at (760) 602-2719 for a complete listing of fees•••
STORM WATER COMPLIANCE FORM /6,1'-//!) TIER 1 CONSTRUCTION SWPPP CB
E-29 swJ.10-,1q12_
STORM WATER POLLUTION PREVENTION NOTES BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials ,. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE BMPs ControlBMPs Management BMPs PoHution Control BMPs
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION i OF EROSION AND SEDIMENT CONTROi.. BMPs 'WHEN RAIN § ~ ~ ~ • § i ~ IS EMINENT. .. 1 .E I i •
THE OIINER/CONTRACTOR SHALL RESTORE All EROSION 2 ~ ~c ~ ]' ~ ]! 'i. 'i ~ ~ $ .i ~ £ i ~ 2. 0 Cg ! 'E .5 .§ C Best Management Practice• ,l! .5 • m ~ 6. • 0 ,._ ii CONTROL DEVICES TO WORKING ORDER TO lHE SATISFACTION . ;; :g Ji ! ~ .!! ~ I! ~ ~ ~ s u .. ~-0 ~ ~ ~ i • ". •• OF THE CITY INSPECTOR AITTR EACH RUN-OFF PRODUCING (BMP) Description ➔ ~ ~ s~ 8 -~ ~-~ 11'<. li 6. •• ;< C ~E i!E •E C l1 0~ ... RAINFALL • • g' O:,;, ~~ U8 Cl>:;::: .!? .. C: :'2& "' 11, ~· ig =e -~ i§ • ~ s" U,:;::: .g u·c .! ~ ! ] ~.,, "~ " ~ J; ~ E
g j ~ ~ " 18 i, ~o co ~ :i ~ J C O oe 0 ~:il 1~ ·-C t:15 •• 3. lHE Ov.t,!ER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION oE 6 ~ ~ ind: 0~ ~in ~ in .. 0 we l'); VI~ /;; C ~~ .. ~ ~ >0 ~"' ~"' 02
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY 0 N n ~ ~ m INSPECTOR DUE TO INCOMPLElE GRADING OPERATIONS OR CASQA Designation ➔ ~ m ~ -n ~ ~ ~ ~ m N n ~ m ' ~
' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ~ ~ l;l l;l ~ ~ ~ ~ llj ~ llj llj I" I" ~ ~ ~ ~ ii! ii! ii! ii! ii! ii! i Construction Acttvily z z z z
4. All REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE Gradin N Disturbance
AT THE ENO OF EACH WORKING DAY WHEN THE FlVE (5) Trench.i CIIYIJtian
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PE CENT Stoc~nilinn
( 40"}. SILT ANO OTHER DEBRIS SHALL BE REMOVED AffiR Drmin ama
EACH RAINFALL. Concrete/Asohalt Sawcuttina
ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM Concrete Flatwork 5. Pavina AGGREGATE. Conduit · e Installation
6. ADE QUA TE EROSION ANO SEDIMENT CONTROL AND PERIMETER Stucco/Mortar Work
PROlECTION BEST MANAGEMENT PRACTICE MEASURES MUST Waste DiSPosol
BE INSTALLED AND MAINTAINED. Staoln av Down Area
E · ment Maintenance and Fuel.in
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALlER Hazardous substance UselStornne
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED Dewater.ia
TO ENSURE COMPLIANCE WITH CITY STORM WA lER QUALITY Site Access Across Dirt
REGULATIONS. Other 111st':
Instructions: 1. Check the box to the left of all applicoble construction activity (first column) expected to occur Wring construction.
2. Located alon~ the t~ of the BMP Table is a list of BMP's with it's corre'ftiond'r,g California Stormwoter Quality Association (CASOA) designation number. Choose one or more BM s you in end to use during construction from the lisl Check e box where the chosen activity row intersects with the BMP column.
3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project.
OWNER'S CERTIFICATE:
I UNDERSTAND AND ACKNOVttEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION PROJECT INFORMATION ACll\llTIES TO THE MAXIMUM EXIDlT PRACllCABLE TO AVOID
THE MOBILIZATION DF PDLLUTANTS SUCH AS SEDIMENT AND TO SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE Site Address: AVOID THE EXPOSURE DF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; AND {2) ADHERE TO, AND AT All TIMES. ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN. Assessor's Parcel Number:
COMPLY WITH THIS CITY APPR0\£D TIER 1 CONSTRUCTION SWPPP SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE THROUGHOUT THE DURATION DF THE CONSTRUCTION ACTIVITIES EROSION CONTROL PLAN. Emergency Contact: :y ~LL,~ rr/L
UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED Name: ,r/lfA ,.T1/
BY THE CITY DF CARLSBAD. _, 6-tJ _.: L,1, ~7 -BMP's are subject to field inspection-24 Hoor Phone: ~, l).
OWNER(S)/O~ER S AGENT NAME (PRINT} Construction Threat to Storm Water Quality
{Check Box)
0WNER(S)/DWNER'S AGENT NAME (SIGNATURE) DATE 0 MEDIUM □LOW
E-29 Page 1 of 1 REV 02/16
1 xx 0 xx -----1 ~ SCALE:
-BMP's are subject to field Inspection-
xx X)(
I
EXJSTII(; SIG.£ FMal.Y ~~ IMSEJIOOff-aaJ _,,
-ff-.JlJlll 8'S£JIEJffff•12.0 .!~~,
SU,T OIWII
7f ff
(r=~ \
LEGEND
PROPfRTY UN[
SILT FfNC[
ABf:R ROl1.
PRf:SERVATION OF D/ISTINC
INL£T PROTrCTION
GRA\.fi 84G BEJIJJ/BARRff:R
DIRECTION/COURS[ OF fl.OW
• DlfG.NO.
Sf-7
SE-5
[C-2
SE-10
SE-6
HYDRAUUC UUtCH/HYCJROSITD f:C-1. f:C-4
STAB/LJZ[D CONSTRUCTION ENTf/ANCE 111-1
UAml/ALS DElJVfRY AND STORAG[ ARf.A ltM-I
1[1,/PQRARt' 111ASH/SOLID WAS1E ltM-5
HAZ.AROOUS AND CONCRETr WU-6, ltM-8
WAST[ IWII.GE:ME:NT
SAN!TAFrY WAS1E WM-9
(PORTABlE TOILET)
SYMBOL
N45"45'45it'
-0-----0---
-x-x-x-x-
1222222221
ggB
cx::x:x::x::>
™ ffll~lllfflffl I ltM-, I
I Wll-5 I
I :::: I I IIM-9 1
•STANDARD DRAWINGS (SE-5, Wll-5, ITC.) CAN 8E FOUND AT TH[
CALIFORNIA STORUWATrR OUAL/IY ASSOCIAnON (CASOI<) WEBS1Tr: http://wn.cobmphondbcoks.com/
QUANTITY
C City of
Carlsbad
DETERMINATION OF
PROJECT'S SWPPP
TIER LEVEL AND CONSTRUCTION
THREAT LEVEL
E-32
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
I'm applying for: □ Grading Permit
Project Name: \NoRk SH£ h
Address:Z.Z-5'7 LE,111:\ND"e ST.
t{Building Permit □ Right-of-way permit □ Other
Project ID: _____ DWG #/CB# __ .,_j..,.,_(.. ___ _
APN Zif,. 'l.4 e':f8-0l Disturbed Area: -,~7_,/""2..,~,.__,Ac
Section 1: Determination of Project's SWPPP Tier Level SWPPP
(Check aoolicable criteria and circle the corresoondina SWPPP Tier Level, then ao ta section 2l Tier Level
Exem11t -No Threat Project Assessment Criteria
My project is in a category of permit types exempt from City Construction SWPPP requirements. Provided
no significant grading proposed, pursuant to Table1, section 3.2.2 of Storm Water Standards, the
following __ permits are exempt from SWPPP reouirements: Exempt
► Electrical ► Patio ► Mobile Home ► Plumbing ► Spa (Factory-Made)
► Fire Sprinkler ► Mechanical ► Re-Roofing ► Sign ► Roof-Mounted Solar Array ................... ........... ........... .. ... . ........ ....... ......................... .... . ...................... .. ····················································· ......................
Tier 3-Significant Threat Assessment Criteria -(See Construction General Permit (CGP) Section I.B)*
D My project includes construction or demolition activity that results in a land disturbance of equal to or
greater than one acre including but not limited to clearing, grading, grubbing or excavation; or,
D My project includes construction activity that results in land disturbance of less than one acre but the
construction activity is part of a larger common plan of development or the sale of one or more acres
of disturbed land surface or,
D My Project is associated with construction activity related to residential, commercial, or industrial Tier3
development on lands currently used for agriculture; or
D My project is associated with construction activity associated with Linear Underground/overhead
Projects (LUP) including but not limited to those activities necessary for installation of underground
and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire,
towers, poles, cables, wires, connectors, switching, regulating and transforming equipment and
associated ancillary facilities) and include but not limited to underground utility mark out, potholing,
concrete and asphalt cutting and removal, trenching, excavation, boring and drilling, access road,
tower footings/foundation, pavement repair or replacement, stockpile/borrow locations.
D Other per CGP
Tier 2-Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat
Assessment Criteria described above and meets one or more of the following criteria:
D Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the
Carlsbad Municipal Code); or,
D Project will result in 2,500 square feet or more of soils disturbance including any associated
construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance
areas and project meets one or more of the additional following criteria: Tier2
• located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or,
• disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or
• disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or
watercourse; and/or
• construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1
throus1h Apr. 30).
Tier 1-Low Threat Assessment Criteria
D My project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt
permit type per above and the project meets one or more of the following criteria: Tier 1 • results in some soil disturbance; and/or
• includes outdoor construction activities (such as roof framing, saw cutting, equipment washing,
material stockpiling, vehicle fueling, waste stockoilina)
* Items listed are excerpt from CGP. CGP governs cntena for triggers for T,er 3 SWPPP. Developer/owner shall confirm coverage
under the current CGP and any amendments, revisions and reissuance thereof.
E-32 Page 1 of2 Rev. 2/16/16
SWPPP Section 2: Determination of Project's Construction Threat Level
Tier (Check applicable criteria under the Tier Level as determined in section 1, circle Construction
Level the corresponding Construction Threat Level, then complete the Threat Level
sionature block belowl
Exempt -Not Applicable -Exempt
Tier3 High Construction Threat Assessment Criteria: My Proiect meets one or more of the
following:
D Project site is 50 acres or more and grading will occur during the rainy season
D Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed,
inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly
to an ESA High
D Soil at site is moderately to highly erosive (defined as having a predominance of soils Tier3 with USDA-NRCS Erosion factors kl greater than or equal to 0.4)
D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1 -April 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
Tier3 Medium Construction Threat Assessment Criteria Medium D All projects not meeting Tier 3 High Construction Threat Assessment Criteria
Tier 2 -High Construction Threat Assessment Criteria: My Proiect meets one or more of
the following:
D Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or
within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an
ESA
D Soil at site is moderately to highly erosive (defined as having a predominance of soils High
with USDA-NRCS Erosion factors k, greater than or equal to 0.4)
Tier2 D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct.
1-Apr. 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
D Site results in 10,000 sq. ft. or more of soil disturbance
Tier2 Medium Construction Threat Assessment Criteria Medium D My project does not meet Tier 2 High Threat Assessment Criteria listed above
Tier 1 -Medium Construction Threat Assessment Criteria: My Proiect meets one or more
of the following:
D Owner/contractor received a Storm Water Notice of Violation within past two years Medium D Site results in 500 sq. ft. or more of soil disturbance
Tier 1 D Construction will be initiated during the rainy season or will extend into the rainy season
(Oct.1-April 30)
Tier 1 -Low Construction Threat Assessment Criteria Low D My project does not meet Tier 1 Medium Threat Assessment Criteria listed above
I certify to the best of my knowledge that the above statements are true and correct. I will prepare and submit an appropriate tier level SWPPP as detenmined above
prepared in accordance with the City SWPPP Manual. I understand and acknowledge that I must adhere to and comply with the storm water best management
practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the penmit type(s) checked above.
The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where it can be shown
that a lesser or higher SWPPP Tier Level is warranted.
Owner/Owner's Authorized Agent Name: Title: City Concurrence: Yes No
(For City Use Only)
Owner/Owner's Authorized Agent Signature: Date: By:
Date:
Project ID:
E-32 Page 2 of 2 Rev. 2/16/16
f
<<~~ ~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLANCHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e-ov
DATE: 7/20/16 PROJECT NAME: SHED W/ DECK PROJECT ID:
PLAN CHECK NO: CB162410 SET#: ADDRESS: 2257 LEVANTE ST
~ T~i~ ~Ian check review is complete and has been APPROVED by the ~~
:;~~~
A Final Inspection by the PLANNING Division is required □ Yes cgJ No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
~ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on ({f!!;J the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: DANIELDOYLE@HOTMAIL.COM
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
..
□ Chris Sexton
760-602-4624 □
Chris.Sexton(iilcarlsbadka.gov
[Z] Gina Ruiz □ 760-602-4675
!, i na. Ru iz!i!!kl!rlsba!!~l!-gov
□
Remarks:
REVIEW#:
1 2 3
[gJ □ □
[gJ □ □
[gJ □ □
[gJ □ □
[gJ □ □
[gJ □ □
Plan Check No. CB162410 Address 2257 LEVANTE ST Date 7/20/16
Review#_;}
Planner GINA RUIZ Phone (760} 602-4675
Type of Project & Use: SHED W/ DECK
Zoning: R-2 General Plan: R8 Facilities Management Zone:§
CFD (in/out) # __ Date of participation: ___ Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: [gJ Item Complete @item Incomplete -Needs your action
Environmental Review Required: YES □ NO [gJ TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAURESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES O NO 0.
CA Coastal Commission Authority? YES O NO 0.
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES □ NO [gJ
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of
Habitat Type impacted/taken, UPDATE!)
lnclusionary Housing Fee required: YES D NO [gJ
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Data Entry Completed? YES □ NO 0
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct
Housing Y/N, Enter Fee, UPDATE!)
Housing Tracking Form (form P-20) completed: YES □ NO □ N/A [gJ
Site Plan: □ □ A\ PROPOSED PATIO COVER MISSING FROM ELEVATIONS. SEE ADDITIONAL 'e) COMMENTS BELOW.
• i
P-28 Page 2 of 3 07/11
I
[8J □ □
[8J □ □
[8J □ □
[8J □ □
□ □ [8J
[8J □ □
□□~
□~
. ---·-----------------
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1 . Applicability: YES O NO [8J
2. Project complies: YES D NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Rear:
Structure Separation:
2. Lot Coverage:
Required 20' Shown 20'+
Required 5' Shown §'.
Required 5' Shown §'.
Required 1Q'. Shown il'.
Required 50% MAX Shown 30%
3. Height: Required 14' MAX /4:12 PITCH STATED ON PLANS)
Shown 14' /REV & OK BYVU
4. Parking: Spaces Required 20' X 20' Shown 3 CAR GARAGE EXISTING W/
NEW PROPOSED DETACHED GARAGE
5. Condominium pennit amendment: Required NOT ALL INFO SHOWN TO
DETERMINE -SEE ADDITIONAL COMMENTS B OW Shown Nrff, SQUARE
FOOTAGE OF PATIO COVER IIV.~£1(..Q""'"..-r µ pas IJ Z'tffvf!r
Additional Comments l"bA~IGialeGK MG. 1:
#1. IF Tiale t:leGK IS A PART GF TiallS l"RGPGSAI Pl FASF APQ IT TG Tiale ebeVATIG~IS
SialeeT A~IQ STATE> ialGiAI FAR GFF Tiale CRGblMQ IT'Nlbb Be.
#~. l"beASe RI.VIS!::: Tiale SGI ffH FbeVATIGM TG SialGW WeRe Tiale eXISTl~IC CRA.t:le IS AT.
#3. PURSUANT TO CHAPTER 21.45.100 (Bl (1) /f) (i) ANY ADDITIONS OR ACCESSORY USES OVER
10% OF THE EXISTING FLOOR AREA OF THE STRUCTURE MUST APPLY FOR AN AMENDMENT TO
THE CONDOMINIUM PERMIT IN ORDER TO DETERMINE IF THIS PROJECT REQUIRES AN
AMENDMENT PLEASE INCLUDE THE TOTAL SQUARE FOOTAGE OF THE GARAGE.
PLANCH&iC:K N0. l;
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE~ATE 1 b 1 /; ft'
P-28 Page 3 of 3 07/11