Loading...
HomeMy WebLinkAbout2261 COSMOS CT; ; CB013305; Permit12-13-2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB013305 Job Address Permit Type Parcel No Valuation Occupancy Group °roject Title 2261 COSMOS CT CBAD Tl Sub Type 2130504000 Lot* $9,000 00 Construction Type Reference # CATALINA DESIGN GROUP INSTALL PAINT BOOTH COMM 0 NEW Applicant NORTON RALPH 8029 BALBOA BLVD SAN DIEGO CA 92111 858-279-2813 Status ISSUED Applied 10/18/2001 Entered By JM Plan Approved 12/13/2001 Issued 12/13/2001 Inspect Area Owner WANDER BRANDON H C/O BUSINESS REAL ESTATE MANAGEME 6183 PASEO DEL NORTE #280 CARLSBAD CA 92009 6617 12/13/01 dp01 02 150.88 Total Fees $21067 Total Payments To Date $5979 Balance Due $15088 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $91 99 Meter Size $0 00 Add'l Reel Water Con Fee $59 79 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1 89 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $3700 $000 $000 $000 $000 $21067 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as lees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has pjeviously otherwise expired PERMIT APPLICATIONt CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 PROJECT FOR OFFICE USE ONLY PLAN CHECK EST VAL ^ Plan Ck Deposij Validated E Date W6/ Address (include Bldg/Suite1.3 ; Name (at this address) Legal DescTiption / Lot No Subdivision Name/Number 1 UiJUjg^ IQ/jj.^^ ^OO0 'Total * j^JJumts Assessor s Parcel It . II] Existing Use Proposed Use s— -US' .-••* =P/i/A/>^ Pntirti 532. Description of Work . , ,.. i P SO ftT . #of Stones yl # of Bedrooms # of Bathrooms T?9 ...CONTACTJPERSON: (if dif h»J -i//) j elephone #Name :3 APPLICANTPLICANT t J& Address Contractor Qi::A!g"ent for Contractor City Ovvner QO Agentifor Owner d Stare/Zip Telep Name Address City State/Zip Telephone # : PROPERTY OWNER Name City State/Zip Telephone # CONTRACTOR COMPANY NAME Address (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001) Name State License # Address License Class . V. La I I P *2/ City State/Zip City Business License # _ Telephone # Designer Name Address City State/Zip Telephone State License # 6 WORKERS'COMPENSATION .*=... •-"'" f'"" jr'" " ' -f jf ... "-f".'.' Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations |~1 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued l~l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Sf CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil lines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE_ DATE 7 ;•"OWNER BUILDER DECLARATION i: f ,;;;«fi"" """ ,i:..: ::. jiff f I hereby affirm that I am exempt from the Contractor s License Law for the following reason C] I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) 0 I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) |~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement (~l YES FlNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY S: : : |; % „..._ J Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' O YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' l~l YES Q NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' f~l YES l~] NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE Of OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT "8" CONSTRUCTION LENDING AGENCY ....::.. 9r f" .:., * ;i 'S'C •• .. "E-- ;i;..... '-,.... I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS 9, APPLICANT CERTIFICATION ,.j:f J :::: ^ " .,f" , ;.3 " f"" jf ..in, '••• "*"::: ,.:;;,-..:::':::: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every authorizedfcy-srjch permit is not com; at any ti^ie after the work is commenci APPLICANT e provisions of this Code shall expire by limitation and become null and void if the building or work e date of such permit or if the building or work authorized by such permit is suspended or abandoned ection 106 4 4 Uniform Building Code) DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Lite Plan Check #06/03/2002 Permit # Project Name Address Contact Person Sewer Dist Inspected^ By /St Inspected Bv Inspected Bv Comments CB013305 CATALINA DESIGN GROUP INSTALL PAINT BOOTH 2261 COSMOS CT N/A Phone CA Water Dist CA Date *~- / / ' , ^^^i^^^L^ Inspected 3'^/'/& U Date Inspected Date Inspected • Permit Type Sub Type Lot 0 3— Approved ^ — ~* Approved Approved • Tl ^ COMM ^x" Disapproved Disapproved Disapproved • < • • •> • City of Carlsbad Bldg Inspection Request For 06/04/2002 Permit* CB013305 Title CATALINA DESIGN GROUP Description INSTALL PAINT BOOTH Inspector Assignment TP Sub Type COMM 2261 COSMOS CT Lot Type Tl Job Address Suite Location APPLICANT HORTON RALPH Owner CATALINA DEVELOPMENT L L C Remarks CARRIED OVER FROM MONDAY Total Time Phone 6192792813 Inspector Requested By CARRIED OVER Entered By CHRISTINE CD Description 14 Frame/Steel/Boltmg/Weldmg 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers 31 Act Comments Associated PCRs PCR02069 PENDING Inspection History Date Description Act Insp Comments EsGil Corporation In Partnership with Government for Building Safety DATE 11/21/01 a APPLICANT a JURIS JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO O1-3305 SET II PROJECT ADDRESS 2261 Cosmos Court PROJECT NAME Catalma Design Group - Two Spray Booths The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Coloration staff did not advise the applicant that the plan check has been completed ] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) //• Fax # Mail Telephone Fax In Personf/\~^^ XI REMARKS Applicant to make changes marked in red to City held sets. The applicant to hand carry the plans directly to the Crt/of Carlsbad this does not assure a permit will be issued the City may have other corrections By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 11/14/01 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 <> (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for Building Safety DATE 1O/30/01 Q^APPLICANT JURISDICTION City of Carlsbad a FILE PLAN CHECK NO O1-3305 SET I PROJECT ADDRESS 2261 Cosmos Court PROJECT NAME Catahna Design Group - Two Spray Booths Q The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X] The applicant's copy of the check list has been sent to Ralph Norton 8039 Balboa Blvd Suite A, San Diego, CA 92111 Esgil Corporation staff did not advise the applicant that the plan check has been completed [Xj Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ralph Morton . Telephones 858-279-2813 Date contacted i W~ofbf (by f^-Ax) Fax # Mail ^ Telephone Fax^ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA* D MB D EJ D PC 10/22/01 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 01-3305 10/30/01 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 01-3305 OCCUPANCY H2 TYPE OF CONSTRUCTION N/A ALLOWABLE FLOOR AREA N/A SPRINKLERS'? REMARKS DATE PLANS RECEIVED BY JURISDICTION 10/18/01 DATE INITIAL PLAN REVIEW COMPLETED 10/30/01 JURISDICTION City of Carlsbad USE Spray Booth ACTUAL AREA 532 sf STORIES 1 HEIGHT OCCUPANT LOAD 5 DATE PLANS RECEIVED BY ESGIL CORPORATION 10/22/01 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e. plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad 01-3305 10/30/01 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC 3 Indicate the use of all spaces adjacent to the spray booth Please indicate the occupancy of the adjoining areas to determine if an occupancy separation is required 4 Please provide evidence of Fire Department approval 5 Please list the manufacturers name and model number for both spray booths on the plans 6 A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible The building official may require a technical report to identify and develop methods of protection from hazardous materials Section 307 1 6 a) Clearly show the types and amounts of hazardous material that are being stored or used, as per the UBC, Table 3-D and 3-E classifications Provide the material safety data sheets (MSDS) b) Clearly show where in the buildings each type of hazardous material is being stored or used City of Carlsbad O1-33O5 10/30/01 When the quantities of hazardous materials require secondary containment please show compliance with the following c) Provide calculations for required containment in each area of the buildings, as per UBC, 307 2 5 d) Provide a written response to show how Spill Control and Drainage are being handled as required in UBC, Sections 307 2 3 & 307 2 4 e) Provide the required manual shutoff control for ventilation equipment as per UBC, Section 1202 2 3 7 Detail on the plans the construction of the roof framing head outs for the equipment duct penetrations Per Section 106 3 3 8 Detail exhaust ventilation system compliance with UMC Chapters 5 & 6 a) Detail the required make-up air as per UMC, Section 505 6 b) Detail the exhaust outlet clearances as per UMC, Sections 504 6 & 505 9 c) Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces UMC, Section 505 1 Please indicate clearly on the plans if a rated shaft is required to provide separation between the H2 spray booth and the adjacent occupancy d) Please indicate on the plans if the duct requires any change in direction to provide the required clearances from existing building structures or to provide the clearances per sections 504 6 and 505 9 If so please detail duct support as per UMC, Section 609 6 e) Detail fire protection as per UMC, Section 609 7 f) The exhaust and make-up air systems shall be connected by an electrical interlocking switch UMC, Section 402 4 g) Detail clearances from combustibles as per UMC, Sections 609 8 & 609 8 1 If a rated shaft is required please detail the clearances and construction 9 Please provide an equipment schedule for the exhaust and make-up air equipment 10 Please provide a panel schedule, indicate on the schedule new and existing loads, indicate on the plans the location of the panel 11 Please note on the plans "AC Cable is not allowed NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" Per City of Carlsbad 12 Please attach the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans City of Carlsbad 01-33O5loyso/oi 13 When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features b) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features c) Please show the method of compliance to the above items To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you CITY OF CARLSBAD POLICIES AND PROCEDURE 1UMBER 80-6 SUBJECT ROOF MOUNTED EQUIPMENT EFFECTIVE 5/1/92 SECTION BUILDING DEPARTMENT SUPERSEDES 80-6(9/10/80) 80-6(5/01/81) 3URPOSE NTENT PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS A Maintain roof integrity B Prevent hazardous condition to firemen who must fight fire on the roof C Provide an installation that is aesthetically sensitive to the building and the adjoining properties DOLICY 1 All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department 2 All equipment shall be specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department 3 All roof mounted equipment shall be on a platform which shall be an integral part of the roof—flashed and waterproofed When a screen is approved, it shall have as few roof connections as possible and be structurally adequate 4 All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official 5 Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in general proximity 6 Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official 7 Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused openings properly sealed to maintain roof integrity *The architect should, through design, conceal the heating/AC unit and other equipment whether they are on the roof or elsewhere initiated By Approved B City of Carlsbad 01-3305 10/30/01 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PREPARED BY Doug Moody BUILDING ADDRESS 2261 Cosmos Court PLAN CHECK NO 01-3305 DATE 10/3O/O1 BUILDING OCCUPANCY H2 TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 532 cb Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 10,000 10,000 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review I Repetitivp Fee Repeats 0 Complete Review D Other r-i Hourly Structural Only Hour Esgil Plan Review Fee $99 69 $6480 $5583 Comments Sheet 1 of 1 macvalue doc City of Carlsbad ;R-u b tip?. fWp irk^y?: Eri g I h e <e r i h g BUILDING PLANCHECK CHECKLIST DATE BUILDINGDDRESS PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER n PLANCHECK NO CB 0 f ( 6cvw&^ Ur EST VALUE f 0 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to build LA Right-of-Wav permit is required prior to construction of the following improvements DENIAL Please see^the attached report of deficiencies marked wffh D V/lake necessary corrections to plans or spepficatiprfs for compliance with applicable codes and-s1andarp#] Submit corrected plans and/or specifications to tHis ./office for review Date Date Date By By By FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date ATTACHIVfENTS U Dedication Application D Dedication Checklist O Improvement Application D Improvement Checklist G Future Improvement Agreement G Grading Permit Application G Grading Submittal Checklist Q Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist and Information Sheet Q Sewer Fee Information Sheet ENGINEERING DEPT CONTACT PERSON Name KATHLEEN M FARMER City of Carlsbad Address 1635 Faraday Avenue Carlsbad CA 92008 Phone (760) 602-2741 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract A-4 CA 920O8|-7314 • (76O) 602-2720 • FAX (760) BUILDING PLANCHECK CHECKLIST gRD D D SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow B Existing & Proposed Structures C Existing Street Improvements D Property Lines E Easements 2 Show on site plan F Right-of-Way Width & Adjacent Streets G Driveway widths H Existing or proposed sewer lateral I Existing or proposed water service J Existing or proposed irrigation service A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION H \WORD\DOCSCHKLST\BuiMina Planche* Cklsl Form (Generic) doc BUILDING PLANCHECK CHECKLIST 1ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE D Q D 4a Project does not comply with the following Engineering Conditions of approval for Project No D D D 4b All conditions are in compliance Date DEDICATION REQUIREMENTS CH 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15.000. pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/z" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the H \WORD\DOCS\CNKLST\Buildins Planctieck Cklst Form (RIDDLE HARVEY 7 12 00) doc ..ST 2ND 0RD BUILDING PLANCHECK CHECKLIST checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date CU 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows 6c Enclosed please find your Future Improvement Agreement Please return agreement signed and notarized to the Engineering Department Future Improvement Agreement completed by Date D D D 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities (cut, fill import, export) 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date D D D 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) H \WORD\DOCS\CHKLST\Building. Plancheck Cklst Form (GENERIC 7 14-00) doc BUILDING PLANCHECK CHECKLIST 1ST D oND D 3RD n D D D D D D D D D D D D D D D 7d No Grading Permit required 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities Right-of-Way permit required for INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is oTTEhe hWA Exempt "ListYou may telephone (760) 438^2722, extension for assistance Industrial Waste pe Date it accepted by 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first 11 Q Required fees are attached J2l No fees required WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service H WORD\DOCS\CHKLST\Buildin8 Plancteck Ckkt Form (Generic) doc 1ST •>ND 3RD D D D 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water H \WORD\DOCSVCHKLST\BuiUing Plancheck CMsl Form (Genenc) doc Rev 7/14/00 1ST OND oRD BUILDING PLANCHECK CHECKLIST i ^ «_/ service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future D D CD 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this D CD CH 13 Additional Comments H \WORD\DOCS\CHKLST\BuiUing Planeheck Cklst form (Genenc) doc D D ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal Address Bldg Permit No Prepared by Date Checked by Date EDU CALCULATIONS List types and square footages for all uses Types of Use Sq Ft /Units Sq Ft /UnitsTypes of Use APT CALCULATIONS List types and square footages for all uses Types of Use Sq Ft /Units Types of Use Sq Ft /Units EDU's EDU's ADT's ADT's FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1 PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS = $ D 2 TRAFFIC IMPACT FEE ADT's/UNITS X FEE/ADT = $ D D D D 3 BRIDGE AND THOROUGHFARE FEE ADT s/UNITS 4 FACILITIES MANAGEMENT FEE UNIT/SQ FT 5 SEWER FEE EDU's BENEFIT AREA EDU's 6 SEWER LATERAL ($2,500) (DIST X ZONE X X X #1 DIST #2 FEE/ADT FEE/SO FT /UNIT FEE/EDU FEE/EDU DIST #3 ) -$ -$ -$ = $ = $ D 7 DRAINAGE FEES PLDA_ ACRES HIGH /LOW FEE/AC = $ D 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION Word\Docs\Misforms\Fee Calculation Worksheet Iof2 Rev 7/14/00 n n ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal Address Bldg Permit No Prepared by Date Checked by Date EDU CALCULATIONS List types and square footages for all uses Types of Use Sq Ft /Units Types of Use Sq Ft /Units APT CALCULATIONS List types and square footages for all uses Types of Use Sq Ft /Units Types of Use Sq Ft /Units EDU's EDU's ADT's ADT's FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO PARK AREA & # X NO UNITS =$ D 1 PARK-IN-LIEU FEE FEE/UNIT D 2 TRAFFIC IMPACT FEE ADT's/UNITS FEE/ADT = $ n n n n 3 BRIDGE AND THOROUGHFARE FEE ADT's/UNITS 4 FACILITIES MANAGEMENT FEE UNIT/SO FT 5 SEWER FEE EDU's BENEFIT AREA EDU's 6 SEWER LATERAL ($2,500) (DIST #1 DIST #2 X FEE/ADT ZONE X FEE/SO FT /UNIT X FEE/EDU X FEE/EDU • DIST #3 ) = $ = $ = $ = $ = $ D 7 DRAINAGE FEES PLDA_ ACRES HIGH /LOW FEE/AC = $ D 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION Word\Docs\Misforms\Fee Calculation Worksheet 1 Of 2 Rev 7/14/00 DATE BUILDING ADDRESS PROJECT DESCRIPTION _ ASSESSOR'S PARCEL NUMBER City of Carlsbad PUblic Wbfks — Engi n ee r i n g BUILDING PLANCHECK CHECKLIST n PLANCHECK NO CB 6 I " 33'0J/ / X» 1 1 Of EST VALUE ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build [A Right-of-Way permit is required prior to construction of the following improvements nda Please marked or sp codes specifications to By By By DENIAL at^ched report of deficiencies lake necessary corrections to plans for compliance with applicable Submit corrected plans and/or ice for review Date Date Date By FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist and Information Sheet n Sewer Fee Information Sheet ENGINEERING DEPT CONTACT PERSON Name KATHLEEN M FARMER City of Carlsbad Address 1635 Faraday Avenue, Carlsbad, CA 92008 Phone (760) 602-2741 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract A-4 CA 9200^-7314 • (76O) 6O2-272O • FAX (760) 602*85©® f- 4 ST pND 3RD D D D D D D ODD D D D D D D D D D BUILDING PLANCHECK CHECKLIST 7d No Grading Permit required 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is drTThe EWA Exempt ListYou may telephone (/t>u; 43b-^722, extension 7 tor assistance Industrial Waste permit accepted Date <£< 10 NPDES PERMIT £2U& Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first 11 QRequired fees are attached J3No fees required WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service H JWORWDOCSMXKLS'nBuiktaiB Plancheck Cklst Form (Generic) Doc Rev 7/14/00 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) DATE TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE Docs/Misrorms/Pwnnrng Engineering Aoorovais Carlsbad Fire Department 013305 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 12/13/2001 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Ralph Norton 8039 Balboa Blvd City, State San Diego CA 92111 Plan Checker Job Name Catalma Design Job# 013305 Job Address 2261 Cosmos Ct Bldg# CB013305 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards LJ Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2nd 3rd 013305 FDFile# Othfir Agpnny in Carlsbad Fire Department °13305 "1635 Faraday Ave Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report 12/13/2001 _ Reviewed by Q Name Ralph Morton Address 8039 Ba|boa Blvd City, State San Diego CA 92111 Plan Checker °13305 Job Name Catalma Design Job Address 2261 Cosmos ct Ste or Bldg No Sprinkler plans must be submitted under a separate permit submittal to the fire department Plan approval is for spray booth only (Carlsbad Fire Department 013305 F 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category Date of Report 11/21/2001 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Ralph Morton 8039 Balboa Blvd City, State San Diego CA 92111 Plan Checker Job Name Catalma Design Job# 013305 Job Address 2261 Cosmos ct u Bldg# CB013305 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements U Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards 0 Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval \ Review FD Job # 1st ?nd 3rrl 013305 FDFile# Other Agency in Requirements Category Building Plan Requirement Pending 05 32 Additional Requirements or Comments 1 336 square foot spray booth must be provided with two exits spaced a minimum of 1/2 the diagonal distance of the booth apart Show the second exit on the site plan Exits shown on the booth plans are not the minimum distance apart 2 Page 5 spray booth plan should specify 336 square feet 3 Ducts conveying vapors must terminate a least 30 feet from the property line, 10 feet from openings in the building, 6 feet from exterior walls or roofs and 30 feet from combustible walls or openings into the building which are in the direction of the exhaust discharge Please note on the plans 4 Specify the rated CFM for the exhuast motors for each booth 5 A three feet clearance is requned from the spray booth to combustible walls The walls adjacent to the spray booth must be at least three feet away be of non-combustible construction or be provided with two layers of type X drywall Please specify on the plans Pagel 11/21/01 Hazardous Materials SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE Management Division urrnsmtmmimn CIVITT IF till IIECQ Business Name Contact Person Telephone Mailing Address Wll City State Zip DWf. Plan File* Site Address City State Zip Plan File* PART I FIRE DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use process, or store any of the following hazfltdpijs materials^ If _any o£ the items are circled applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal *.- i_~i "-.^ ^j. ^9 *$<$. 1 Explosive or Blasting Agents 4 Flammable Solids 7 Pyrophoncs 10 Cryogenics ' 13 Corrosives ^Compressed Gases 5 Organic Peroxides 8 Unstable Reactives 1 1 Highly Toxic or Toxic Materials 1 4 Other Health Hazards ^"Flammable or Combustible Liquids 6 Oxidizers _ 9 Water Reactives 1 2 Radioactives _ 'ft 45 PART II COUNTY OF SAN DIEGO HEALTH DEPARTMENT HAZARDOUS MATERIALS MANAGEMENT DIVISION CONTINGENCY PLAN REVIEW If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Matenals Management Division 1255 Imperial Avenue 3rd Floor San Diego CA 92186-5267 Telephone (619) 338-2222 prior to the issuance of a building permit FEES MAY BE REQUIRED Yes No Is your business listed on the reverse side of this form? Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons 500 pounds, 200 cubic feet or carcinogens/reproductive toxins m any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Acutely Hazardous Matenals? OFFICE USE ONLY | } RMPP Exempt L Data Initials |~| RMPP Required [ Date Initials f~] RMPP Completed Date initials PART III SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes applicant must contact the Air Pollution Control District 9150 Chesapeake Drive San Diego, CA 92123 Telephone (619) 694-3307 prior to the issuance of a building permit YES NO Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution Control Distnct Permit Categories on the reverse side of this form? (ANSWER ONLY IF QUESTION 1 IS YES ) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K. through 12) as listed in the current Directory of School and Community College Distncts, published by the San Diego County Office of Education and the current California Private School Directory compiled in accordance with provisions of Education Code Section 33190? Briefly descr!BeTiatur?^rtrie intended business activity >^ ~"•™^~ 2 |—| Name of Owner or Authorized Agent ARTHUR Signature of Owner or Authonzed Agent I declare under penalty of penury that to the best of my knowledge and belief the responses made harem are true Do not write below thie/ffnV „ FIRE DEPARTMENT OCCUPANCY CLASSIFICATION BY Date BUILDING PERMIT BUT NOT OCCUPANCY APCD APPROVED FOR OCCUPANCY COUNTY HMMD APCD EXEMPT FROM PERMIT REQUIREMENTS COUNTY-HMMD APCD Environmaitil Health Service* DHS HM 9171 (6792) County of San Diego Department of Health Service! 5 1V tfc s u; u .0)~\fa N.X -A so fe CAL NAMESoor is 3; «o £ § (A 3 30m> »fli>«_ ^M *ii•** 7**nnilI £§0>sr =•?» aM CD II I M M Ii ! 8 5 a •o& atom s 07-21-2003 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR03136 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 2261 COSMOS CT CBAD PCR 2130504000 Lot# 0 $0 00 Construction Type NEW CATALINA DESIGN REV ELEC PLAN Status ISSUED Applied 07/07/2003 Entered By SB Plan Approved 07/21/2003 Issued Inspect Area 07/21/2003 Applicant KEYSTONE INC JM 7725 OTHELLO AVE SAN DIEGO CA92111 619 292-9489 Owner CATALINA DEVELOPMENT L L C 2261 COSMOS CT CARLSBAD CA 92009 Plan Check Revision Fee Additional Fees $12000 $000 Total Fees $12000 Total Payments To Date SO 00 Balance Due $120 00 0020 07/21/03 0002 01 02 CGP 120-00 FINAL APPROVAL Inspector NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY *o water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CIT/ OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 ; PROJECT-INFORMATION FOR OFFICE USE ONLY PLAN CHECK EST VAL Plan Ck Deposit Validated By N/ Address (include Bldg/Suite #)Business Name (at 1 Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use Proposed Use Descriptionjif V\iork £ 2 I SQ FT #of Stories # of Bedrooms # of Bathrooms **JCJfx r** i^*~ * r • ™ ->^ T**-^^ i | TT T *^ 1 1 Name 3 APPLICANT ^nfcpntractor D Address Agent for Contractor D Owner City n Agent foPOwner State/Zip Telephone ff Fax # Name 4' PRbPERTY?OWNERn Address City State/Zip Telephone # Address City State/Zip Telephone #Name 5 CONTRACTOR COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # 6 WORKERS COMPENSATION , ;. Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~l I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued l~l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE T"" OWNER BUILDER" DECLARATION" ,;;' Jjlj "' ... ;i:r jl: I hereby affirm that I am exempt from the Contractor s License Law for the following reason 0 I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES l~lNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY : JiF „ J t P , N Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? Q YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' l~l YES l~l NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' l~l YES l~l NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 18 ^ CONSTRUCTION LENDING AGENCY ••••• -s"^'^TJ .,;>" >•>•*.:.«• " ,, i.- <• I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER S NAME LENDER S ADDRESS 9 APPLICANT CERTIFICATION " "I Jijlf* : "'_„ '"' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued^Jjjythe building Official ander the provisions of this Code shall expire by limitation and become null and void if the building or work from the date of such permit or if the building or work authorized by such permit is suspended or abandoned days (Section 106 4 4 Uniform Building Code) authorized by such permit is not /t any time after the work is o in 180 nod of APPLICANT S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance EsGi! Corporation In (Partnership with government for (BmCtfing Safety .. DATE 7/18/03 Q APByCANT JURISDICTION City of Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO O1-3649 PCR03-136 SET I PROJECT ADDRESS 2261 Cosmos Ct PROJECT NAME Catahna Development - Revision to Electrical The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are'submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) J-"! ^x Fax # Mail Telephone Pax In Person /r\*' REMARKS Applicant to add note \ryfl&a on sheet E-1 to city held sets By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 7/8/03 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O1-3649 PCRO3-136 7/18/03 - " VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad 136 PREPARED BY Doug Moody BUILDING ADDRESS 2261 Cosmos Ct BUILDING OCCUPANCY B/F1 PLAN CHECK NO 01-3649 PCR03- DATE 7/18/03 TYPE OF CONSTRUCTION VN BUILDING PORTION Revision Air Conditioning Fire Sprinklers TOTAL VALUE Junsciction Code 1QQ4 I IRr Rnilrlinn Pprmit- AREA ( Sq Ft ) cb -pp V i Valuation Multiplier By Ordinance Reg Mod VALUE ($) 1994 UBC Plan Check Fee $12000 Type of Review [^Repetitive Fee ~^i Repeats D Complete Review D Other m Hourly Structural Only Hour* Esgil Plan Review Fee $9600 * Based on hourly rale Comments Sheet 1 of 1 macvalue doc