HomeMy WebLinkAbout2262 Avenida Magnifica; ; PC160054; PermitPermit Print Date: 05/25/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2262 Avenida Magnifica BLDG-Migrated 1672503800 $ 0.00 Work Class: BLDG-Migrated Lot#: Reference#: Construction Type Bathrooms: Orig. Plan Check#: Plan Check#: Description: THE RESERVE: RENOVATE 31 BLDGS 16 UNIT TYPES FOR A TOTAL OF 450 UNITS Applicant: Owner: MARK CARNIGHAN DECRON PROPERTIES CORP 3190 Airport Loop Dr Costa Mesa, CA 92626-3421 714-241-8944 FEE MANUAL BUILDING PERMIT FEE Total Fees: $ 15,055.16 Building Division 6222 Wilshire Blvd, 400 LOS ANGELES, CA 323-297-3826 Total Payments To Date : $ 15,055.16 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: {city of Carlsbad Permit No: PC160054 Closed -Withdrawn 08/22/2016 05/25/2018 AMOUNT $15,055.16 Balance Due: $0.00 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING D ENGINEERING Ccityof Carlsbad JOB ADDRESS ~u 2. CT/PR iECT # Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov SUITEf/SPACEt/UNln # OF UNITS # BEDR M # BATHROOMS 0 BUILOING OFIRE 0HEALTH Plan Check No. ~ Est. Value CONSTR. TYPE C. GROUP VA EXISTING USE AIR CONDITIONING FIRE SPRINKLERS YES 0No8 YES0 No.8'J APPLICANT NAME HAR.le: ADDRESS ~ ~1..1.. /,,.l 11..5111U:-SJ..YD. sv,-re. 400 STATE CA ZIP <=too48 PHONE ''* ;l."tl f{~f FAX f!,71 EMAIL EMAIL M~P.K. l~t-t'°"'-<!.-Mv.SS~~tU:c;rS • c.~t1 YAMA.PA C!-E~oK . CClf1 DESIGN PROFESSIONAL ADDRESS "$(1-o PHONE 71 STATE CA FAX 7'("( CONTRACTOR BUS. NAME ADDRESS ZIP CITY 6:;J..t:. PHONE '1 ( EMAIL EMAIL M(:.AP..H.'"-b-tAO< <!.. H ussetz.,4..£c.11t~e~. Get,,,( STATE LIC. # STATE LIC.# G (5.,:281 STATE ZIP FAX Cl.ASS CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve. demolish or repair any structure. prior to its issuance, also reQuires the applicant for such per.mil to file a signed statement that he is licensed pursu~nt to the provisions of the Contractor'? License Law !Chapter 9. comme.nding with Section 7000 of Division 3 of the Business and Professions Code} or {hat he 1s exempt therefrom, and the basis for the alleged exemption. Any v1olat1on of Section 1031.5 by any applicant for a permit subJects the applicant to a civil penalty of not more than five hundred dollars {$500)). . WORKERS ' COMPENSATION Workers' Compensation Declaration: I hereby afflm1 under penalty of perjury one of tile following c1edara_tions: 8 I have and will maintain a certificate of consent to self-insure for workers· compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as reQuired bv Section 3700 of the Labor Code. for the performance of the work for which this permit is issued. My workers' compensation insurance earner and policy number are: Insurance Co. Policy No. Expiration Date--------- ~ section need not be completed if the permit is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the perfonnance of the work for which thiS permit is issued, I shall not empkly any person in any manner so as to became subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars {&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor coda, inttrffl and attorney's fees. JES CONTRACTOR SIGNATURE 0AGENT DATE OWNER-BUILDER DECLARATION I hereby afflm1 that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my emplOyees with wages as their sole compensalion. will do the work and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himse~ or through his own employees. provided that such improvements are not Intended or offered for sale. if, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contracto(s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contracto(s License Law). t am exempt under Section usiness and Professions Code for this reason: 1. t personally plan to provide the major labor and materials for construction of the proposed property improvement O ves O,o 2. t (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the follOwing person to coordinate, wpervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted {hired) the following persons to provide the work indicated (include name I address I phone I type of work): JES PROPERTY OWNER SIGNATURE 0AGENT DATE EsGil Corporation In (l'artnersfiip witfi government for IBui(aing Safety DATE: OCT.27,2016 JURISDICTION: CARLSBAD PLAN CHECK NO.: PC16-0054 SET: II PROJECT ADDRESS: 2262 AVENIDA MAGNIFICA PROJECT NAME: THE RESERVE AT CARLSBAD -RENOVATION D APPLICANT 8--;ttJRIS. D PLAN REVIEWER D FILE [:8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [:8J EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: MARK CAA~JIGI IA~J -Telephone#: 714-241-8944 Date contacted: (b() ~') Email: mcarnighan@musserarchitects.com Mail Telephone Fax QPerson [:8J REMARKS: Scope of work: 450-unit apartment rehab & renovation including kitchen & bath remodel with minor structural changes. By: ALI SADRE, S.E. Enclosures: EsGil Corporation D GA D EJ D MB D PC 10/20 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In (J'artnersfiip witfi qovemment for '13ui{aing Safety DATE: SEPT. 6, 2016 JURISDICTION: CARLSBAD PLAN CHECK NO.: PC16-0054 SET:I PROJECT ADDRESS: 2262 AVENIDA MAGNIFICA PROJECT NAME: THE RESERVE AT CARLSBAD -RENOVATION ~APPLICANT llr JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Es Gil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: MARK CARNIGMAN CARNIGHAN Telephone#: 714-241-8944 Date contacted: q /~fl b (by:.J)<.) Email: msarnilclmaA@musserarelclitests.som mcarnighan@musserarchitects.com v"t~Mail v'telephone Fax In Person ~ REMARKS: Scope of work: 450-unit apartment rehab & renovation including kitchen & bath remodel with minor structural changes. By: ALI SADRE, S.E. Enclosures: EsGil Corporation [8] GA [8] EJ O MB O PC 8/22 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 CARLSBAD PC16-0054 SEPT.6,2016 GENERAL PLAN CORRECTION LIST JURISDICTION: CARLSBAD 0054 PLAN CHECK NO.: PC16- PROJECT ADDRESS: 2262 AVENIDA MAGNIFICA CONSTRUCTION: V-A & V-B; SPRINKLERS: NONE; STORIES: TWO & THREE; OCCUPANCY: R2/U; HEIGHT: NO CHANGE; USE: APTS. & APTS. ATOP GARAGES; DATE PLAN RECEIVED BY ESGIL CORPORATION: 8/22 REVIEWED BY: ALI SADRE, S.E. FOREWORD (PLEASE READ): DATE REVIEW COMPLETED: SEPT.6,2016 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • GENERAL • Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring JJt1S)_ corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. CARLSBAD PC16-0054 SEPT.6,2016 • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes D No • ARCHITECTURAL 1. On Sheet A-B1.02, clarify detail A4/A-B2.012, as referenced on Building #2275. [There is no such sheet in the submitted package]. 2. Please specify where Sheet A-B2.00C is called out on the site plans. 3. Detail G4/A-B2.52, as cross referenced on Plan D (R), on sketch G4/A-B2.06, is incorrect. 4. Please note on plans if the first occupancy for this project was prior to March 13, 1991. If so, the HC accessibility standards do not apply to the alteration, repair, or rehab. Section 1102A.2. 5. As per unit tabulation, on the Cover Sheet, Units BA & H are accessible. If so, please revise the plans to show compliance with the attached HC list. 6. Please specify on plans that the existing parking, walks, curbs, ramps, stairs, path of travel, etc. are HC accessible, subject to field verification. Please see attached list for additional details. 7. Please identify the all bearing walls and shear walls (SW's) versus non-bearing partitions on floor plans via a legend, subject to field verification. • FIRE-RATED CONSTRUCTION • (the following only applies to the areas affected by the remodel/rehab) 8. Walls and floors separating dwelling units in the same building, shall be fire partitions or horizontal assemblies as required by Sections 708 and 711. Sections 420.2 and 420.3. This applies to both two & three story buildings. 9. Provide details on plans for the fire-resistive construction. Include floor/ceiling and wall assemblies, etc. Be sure to list with each detail the basis of approval (U.L. listing number, ICC research report, etc.). This only applies to the party walls (not interior unit walls) affected by the remodel, repairs. 10. Detail how fire-resistive wall construction will be maintained at built-in wall fixtures, electric panels exceeding 16 square inches in area, etc. Section 714.3.2. 11. Provide a note on the plans stating: "Penetrations of fire-resistive walls and floor- ceilings shall be protected as required in IBC Section 714." CARLSBAD PC16-0054 SEPT.6,2016 12. Detail on the plans how fire-resistive wall and ceiling protection will be maintained at all duct penetrations, such as at fans and vents. Section 717. 13. Fire dampers shall be installed per Section 717.5 at all duct and air transfer openings of: a) Ceilings of fire-resistive floor-ceiling assemblies (this applies to between units) or roof- ceiling assemblies (this applies to penetration into existing roof/ceilings on 3'' floor). b) Fire barriers (this applies to party walls). c) Shaft enclosures (smoke dampers are also required). 14. Steel electrical outlet boxes at fire barrier walls (or party walls) shall not exceed sixteen square inches, shall not exceed 100 square inches per 100 square feet of wall, and shall be separated by a horizontal distance of twenty-four inches when on opposite sides of a wall. Section 714.3.2. [A reminder that fire barriers are also used at the separation of the R occupancies & adjacent common areas, i.e., laundry room, corridors, etc.]. 15. Please show how the one hour rated roof/ ceiling assemblies are maintained at the new attic access locations. [This applies to the one-hour rated construction in 3-story buildings]. Please provide details and references on plans as required. 16. Ducts penetrating fire barriers at occupancy separations must have fire dampers. Section 717.5.2. a) In California, Section 717.5.2 was modified for Group R occupancies, to require smoke dampers in addition to fire dampers. • SOUND TRANSMISSION 17. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits or heating, ventilating or exhaust ducts shall be sealed, lined or insulated or treated to maintain the required sound ratings. • MISCELLANEOUS ITEM 18. Please note the average construction cost estimate per unit. • STRUCTURAL 19. Please provide details and references on plans for the typical new headers being installed for relocated doors. 20. Please show typical details and references on plans for the new openings and infill walls. This applies to both non-bearing as well as bearing walls. Provide separate details covering both conditions. 21. Please provide details and references on plans for any SW's, which may be affected by the remodel, or repairs, under this permit. CARLSBAD PC16-0054 SEPT.6,2016 22. Please submit vertical & lateral calculations for all structural work under this permit. [A reminder that the calculation have to be stamped & signed by the CA licensed engineer responsible for their preparation]. 23. Additional corrections may be warranted, once revised plans & calculations are submitted for review and approval. • ADDITIONAL ITEMS 24. Please see attached for P/M/E & HC items. 25. The jurisdiction has contracted with EsGil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil Corporation. Thank you. ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen ELECTRICAL (2013 CALIFORNIA ELECTRICAL CODE) 26. Include a "Scope of Work" on the electrical plans: I'm not sure if the panels, feeders, and services are existing, relocated, existing to stay the same, or new. 27. There are several locations for the kitchen countertop receptacle outlets that are missing. Please review. 28. On the floorplans make it abundantly clear that the panelboard faces into a room and is not installed interior of the clothes closet. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek GENERAL AND ARCHITECTURAL PME ITEMS 29. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued.Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. CARLSBAD PC16-0054 SEPT.6,2016 PLUMBING (2013 CALIFORNIA PLUMBING CODE) 30. As per the California Green Building Code, all existing water closets and associated flushometer valves, if any, must use no more than 1.6 gallons per flush or must be upgraded to new water closets that use no more than 1.6 gallons per flush. 31. Detail 2 on sheet P0.2 shows all new water heaters are to be installed on 36"X36"X6" concrete pad see Structural Drawings. But there are no Structural Drawings. Please correct. 32. Detail 2 on sheet P0.2 shows all new water heater Drip Pans are drained to floor sinks. The plans show no floor sinks. Please correct. 33. Detail 2 on sheet P0.2 shows all new water heater P&T valve drain lines are to drain to mop sinks. The plans show no mop sinks. Please correct. 34. Show the existing and or new water heater types and locations for Plan F, Plan G, Plan J, & Plan H. 35. Plans seem to show new laundry Rooms in Plan B with new clothes washer & clothes dryer, not shown on the plumbing plans. Please correct. MECHANICAL (2013 CALIFORNIA MECHANICAL CODE) 36. Clearly show all proposed changes to the HVAC system, including exhaust fans, kitchen hoods or clothes dryer venting. 37. Plans seem to show new laundry Rooms in Plan B with new clothes washer & clothes dryer, not shown on the mechanical plans. Please correct. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. CARLSBAD PC16-0054 SEPT.6,2016 PRIVATELY FUNDED MULTI-FAMILY DISABLED ACCESS CORRECTION CHECKLIST Note: All Sections referenced are from Title 24 (2013 CBC) • APPLICATION TO EXISTING STRUCTURES 1. These regulations do not apply to the repair, rehabilitation or additions to existing apartment houses, with the first date of occupancy prior to March 13, 1991. Sec. 1101 A.1 and 1102A.2. For the projects prior to this date, they need to comply with the regulations in effect at the time of their construction. • SITE DEVELOPMENT/ACCESSIBLE ROUTE OF TRAVEL: I.e .• please note on plans that the site items are existing HC complying subject to field verification including ramps. walks. parking. stairs, path of travel. etc. See below for details: • ACCESSIBLE ROUTE OF TRAVEL 2. Accessible routes of travel shall be provided from public transportation stops, accessible parking and accessible passenger loading zones, and public streets or sidewalks to the accessible entrance they serve. The accessible route shall to the extent feasible, coincide with the route for general public. Sec. 111 OA.1. 3. At least one accessible route shall connect accessible buildings facilities, elements and spaces that are on the same site. Section 1110A.1. 4. Where more than one route of travel is provided, all routes shall be accessible. Section 111 OA.1.1. 5. If an accessible route has changes in level greater than Y,", then a curb ramp, ramp, elevator or platform lift shall be provided. Stairs shall not be part of an accessible route. Section 1111A.2. • PARKING: Please show loading zones adjacent to the HC parking, as shown on site plans: 6. The plans must indicate if the parking is "assigned" or "not assigned." Depending on the choice, the following applies. 7. If assigned parking is provided at privately funded multifamily building sites, accessible parking shall be provided for min. 2 % of the assigned parking spaces, but not less than one. Min. one space of each type of parking facility shall be made accessible even if the total number exceeds 2%; signage is not required for assigned parking. Sec. 1109A.4. 8. When parking is not assigned to a resident, at least 5% of the parking spaces shall be accessible and provide access to covered multifamily dwellings and facilities (club houses, etc.). Such parking spaces shall be provided with signage by Sec. 1109A.8.8. Such signage shall not be blocked from view by a vehicle parked in the space. Section 1109A.5. 9. Accessible parking shall be located on the shortest possible accessible route of travel to an accessible building entrance. Section 1109A.7.1. 10. In facilities with multiple accessible building entrances with adjacent parking, accessible parking spaces shall be dispersed and located near the accessible entrances. Section 1109A.7.2. 11. When practical, the accessible route shall not cross lanes for vehicular traffic. When crossing vehicle traffic lanes is necessary, the accessible route shall be designated and marked as a crosswalk. Section 1109A.7.3. 12. A vertical clearance of 8'-2" (measured to the lowest projection from the ceiling) shall be maintained to each required accessible parking space. Section 1109A.8.1. 13. Two adjacent accessible parking spaces may be provided with a 23' wide area lined to provide a 9' parking area on each side of a 5' loading and unloading area in the center. Section 1109A.8.5.2. 14. Each accessible space shall be 14' wide and outlined to provide a 9' parking area and a 5' loading and un- loading area. The loading & unloading area may be located on the either side of vehicle. Sec. 1109A.8.5.1. CARLSBAD PC16-0054 SEPT.6,2016 15. One in every eight accessible spaces, but not less than one, shall be served by an access aisle 8' wide minimum and shall be designated van accessible with a sign "Van Accessible" mounted below the symbol of accessibility. Alternately, the parking space may be 12' wide with the access aisle 5' wide. Section 1109A.8.6. The access aisle shall be located on the passenger side of the vehicle. 16. Ramps shall not encroach into any accessible parking space or the adjacent loading/unloading access aisle. Sec. 1109A.8.2.2. 17. The words, "NO PARKING" shall be painted on the ground within each loading/unloading access aisle, located so that it is visible to traffic enforcement officials. Section 1109A.8.5.4 18. The minimum length of each parking space shall be 18'. Section 1109A.8.5.3. 19. At each parking space, a bumper or curb shall be provided to prevent encroachment of cars over the required width of walkways. Section 1109A.8.2.1. 20. The accessible parking space(s) shall be so located that people with disabilities are not compelled to wheel or walk behind parked cars other than their own. Section 1109A.7.5. 21. Surface slopes of parking spaces for physically disabled shall not exceed Y."lft. (2.083 % gradient) in any direction. Section 1109A.8.3. 22. If a parking lot has unassigned parking spaces, then the accessible parking stalls shall be identified by a sign, complying with Section 1109A.8.8. 23. An additional sign shall be posted in a conspicuous place at each entrance to off-street parking facilities or immediately adjacent to and visible from each stall or space. The sign shall not be less than 17"x 22" in size with lettering not less than 1" in height, which states the following: "Unauthorized vehicles parked in designated handicapped spaces not displaying distinguishing placards or license plates issued for physically disabled persons may be towed away at owne~s expense. Towed vehicles may be reclaimed at or by telephoning ___ .. " Sec.1109A.8.8. 24. The surface of each accessible parking space or stall shall have a surface identification duplicating either of the following schemes: a) By outlining or painting the stall or space in blue and outlining on the ground in the stall or space in white or suitable contrasting color the "International Symbol of Accessibility"; or, b) By outlining the "International Symbol of Accessibility" in white on blue background. The symbol shall be located so that it is visible to a traffic enforcement officer when a vehicle is properly parked in the space and shall be 36" high by 36" side. Section 1109A.8.8. • CURB RAMPS 25. Curb ramps shall be constructed at each corner of street intersections and where pedestrian way crosses a curb. Section 1112A.1. 26. Curb ramps shall be a minimum of 4' in width. Section 1112A.3. 27. The slope of the curb ramp shall not exceed 1 vertical to 12 horizontal. If a curb ramp is located where pedestrians must walk across the ramp, then it shall have flared sides which slope at maximum 1 :10. Section 11112A.5. 28. A level landing 4' deep shall be provided at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or flared sides of the curb ramp shall not exceed 1 vertical to 12 horizontal. Section 1112A.6. 29. Show that detectable warnings, extending the full width and depth of the curb ramp, inside the grooved border, are to be installed for all curb ramps (regardless of slope), per Sec. 11 B-705. Only approved DSNAC detectable warning products & directional surfaces shall be installed. Sec. 11 B-705.3, as ref. by Sec. 1112A.9. 30. Curb ramp shall be located or protected to prevent their obstruction by parked cars. Section 1112A.2. 31. All curb ramps shall have a grooved border, 12" wide at the level surface of the sidewalk along the top and each side, approximately o/." on center. Section 1112A.8. CARLSBAD PC16-0054 SEPT.6,2016 • WALKS/ SIDEWALKS 32. All walks and sidewalks subject to these regulations shall have continuous common surface, not interrupted by steps or by abrupt changes in level exceeding Y,", and shall be a minimum of 48" in width. Walks and sidewalks serving individual dwelling units in privately-funded multifamily buildings may be reduced to 36" in clear width. Sec. 1113A.1. 33. When the slope in the direction of travel of any walk exceeds 5%, it must comply with the provisions for pedestrian ramps. Section 1113A.3. 34. Walks shall be provided with a level area not less than 60" by 60" at a door or gate that swings toward the walk, and not less than 48" by 44" deep at a door or gate that swings away from the walk. Such walks shall extend 24" to the side of the strike edge of a door or gate that swings toward the walk. Section 1113A.4. 35. All walks with continuous gradients shall have level areas min. 5' in length at every 400'. Sec. 1113A.2. • RAMPS 36. Any path of travel is considered a ramp if its slope is greater than 5% (1 :20). The slope of the ramp cannot exceed 8.33% (1 :12). Sec. 1114A.2. 37. Ramps serving R occupancies may be 36" clear width when serving S10 occupants. All other ramps shall have a min width of 48". Curb/wheel guides and other appurtenances shall not project into the required clear width. Sec. 1114A.1 . 38. Continuous, full-length handrails are required at each side for all ramps. The handrails are to extend in the direction of the ramp not less than 12" beyond the top & bottom of the ramp. Sec. 1114A.6.1 & 1114A.6.2.3. 39. The handrails must be 34 to 38" above the ramp surface. The size and spacing requirements for ramp handrails are the same as for stairway handrails. Sec. 1114A.6.2. 40. Where a ramp is not bounded by a wall or fence and the ramp exceeds 1 O' in length, there shall be a curb at least 4 inches high, or a wheel guide rail 4" above the ramp surface. Sec. 1114A.7. 41. Top landings shall be not less than 60" wide and shall have a length of not less than 60" in the direction of ramp run. Sec. 1114A.4.2. 42. Intermediate landings shall be provided at intervals not exceeding 30" of vertical rise. Such intermediate landings are to be at least 60", measured in the direction of the ramp. Sec. 1114A.4.1 & 1114A.4.7. 43. The top landing width shall extend a min of 24" past the strike edge of the door. Section 1114A.4.5. 44. Intermediate landings shall be provided at each change of ramp direction. Bottom and intermediate landings at a change of direction over 30° must be at least 72" as measured in the ramp direction. Sec. 1114A.4.1 & 1114A.4.6. • STAIRWAYS: Note: This section shall not apply to exterior stairways serving upper fioors, or to dwelling units not required to be accessible. It applies to other site stairs. 45. Stairways shall have handrails on each side. Sec. 1115A.6.1. 46. The handrails must be 34 to 38" above the nosing of the treads and must extend in the direction of stair run for min. 12" beyond the top nosing & 12", plus the tread width, beyond the bottom nosing. Sec. 1115A.6.2. 47. The handgrip must be between 1-W' to 1-%" wide, or the shape must provide an equivalent smooth gripping surface. Surface of handrails and walls adjacent to the handrails must be free of any sharp or abrasive elements. Edges must have a min radius of 1/8". Sec. 1115A.6.2. 48. Handrails projecting from a wall are to be 1-%" from the wall. Handrails may be located in a recess if the recess is no more than 3" deep and extends at least 18" above the top of the rail. Sec. 1115A.6.2. 49. The handrail must be returned or end in newel posts or safety terminals. Sec. 1115A.6.2. 50. Open risers are not permitted. Sec. 1115A.2. CARLSBAD PC16-0054 SEPT.6,2016 51. The nosing should not project more than 1-Y," past the face of the riser below. Risers shall be sloped or the underside of the nosing shall have an angle not less than 60° from the horizontal. Sec. 1115A.4. 52. The upper approach and lower tread to each stair (and fill stairway treads outside a building) are to be marked by a strip of clearly contrasting color min. 2" wide (a painted strip is acceptable). Sec. 1115A.5. • COMMON FACILITIES 53. General: All common use areas (laundry rooms, etc.) that serve accessible units shall be accessible. Sec. 1127A.1. • INSIDE THE UNIT: Onlvapplicable to accessible units. i.e .• A11/A-B2.51 & A4IA-B2.61: as noted on plans: • INTERIOR PATHS OF TRAVEL 54. Every interior opening or passage door in a covered dwelling unit must provide a min of 32" net clear opening width between the face of the door and the door stop, when the door is in the 90° open position. Section 1132A.3. A 34" door is acceptable, and a standard 6' sliding glass door is acceptable. 55. All interior doors shall have a level area on the swing side of the door that extends 18" past the strike edge of the door. Section 1132A.5.2. 56. Interior doors shall provide a minimum length on both sides of the door of at least 42". Section 1132A.5.1. For doors providing a clear opening width of only 34", this landing may be reduced to 39". 57. The landing on the dwelling unit side of the primary entry door shall have a minimum length of not less than 44". Section 1132A.5.1. 58. Interior passage doors shall have hardware centered between 30" and 44" above the floor, and be openable with a single effort by lever type hardware. Section 1132A.8. 59. The bottom 1 O" of all doors shall have a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Section 11132A.9. • KITCHENS: Onlv applicable to accessible units. i.e .• A11/A-B2.51 & A4/A-B2.61: as noted on plans: 60. Water supply & drain pipes under kitchen sinks shall be insulated or otherwise covered. Section 1133A.7.1. 61. A minimum linear length of 30" of countertop shall be provided for the kitchen sink, and a minimum linear length of 30" of countertop shall be provided for a work surface, both of which shall be designed to enable repositioning to a min height of 28". Sec. 1133A.4: Exceptions: i) Only 5% of covered dwelling units are required to comply with the repositionable countertop requirements. ii) Stone, cultured stone, and tiled countertops may be used without meeting the repositioning requirements. iii) In covered dwelling units, two 15" min width breadboards may be provided in lieu of the required 30" of countertop work surface. 62. The following additional provisions shall be met if repositioning of countertops is required: (Section 1133A.4.1 ): i) Base cabinets, directly under sink and work surface counter areas, shall be removable to provide clearance for a wheelchair. ii) Finished flooring shall be installed on the floor beneath such countertop. iii) The side and back of adjacent cabinets, which may become exposed to moisture or food handling when a countertop is lowered, shall be constructed of durable, nonabsorbent material, appropriate for such uses. 63. Base cabinets directly under the kitchen sink counter area, including toe board and shelving shall be removable without special knowledge or tools. Finish flooring shall be provided on the floor beneath the counter top. There is no exception to this requirement. Sec. 1133A.3. CARLSBAD PC16-0054 SEPT.6,2016 • BATHROOMS 64. Bathrooms shall be designed to comply with one of the following options, per Section 1134A.1: The accessible bathrooms do not seem to comply in units A11/A-B2.51 & A4/A-B2.61. as noted on plans: 65. a) Only one bathroom within the dwelling unit shall be designed to comply with the following: i) Toilet, bathing and shower facilities shall comply with Section 1134A.4. ii) Bathtubs shall comply with Section 1134A.5. iii) Water closets shall comply with Section 1134A.7. iv) Lavatories, vanities, mirrors and towel fixtures shall comply with 1134A.8. v) Bathrooms shall be provided with an accessible route into and through the bathroom. vi) If a door is provided, it shall comply with the requirements of Section 1132A.5 (this requires a landing depth of 42" on each side of the door). vii) A minimum of 18" clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. viii) Switches, outlets, and controls shall comply with Section 1142A. ix) Reinforced walls to allow for the future installation of grab bards around the toilet, tub and shower shall comply with Sections 1134A.6 for showers and 1134A. 7 for water closets. Grab bars shall comply with Section 1127 A.4. 66. Per Section 1134A.3, all "powder rooms" located on floor levels required to be accessible shall comply with items 1 thru 6 of this section. The powder rooms do not appear to comply in accessible units A11/A- B2.51 & A4!A-B2.61. as catted out on the Unit Tabulation Schedule: 1. Accessible Route. Powder rooms shall be provided with an accessible route into and through the powder room and shall comply with Section 1134A.4. 2. Doors. If a door is provided it shall comply with the requirements of Section 1132A.5 (this requires a strike-clearance of at least 18" and a landing depth of 42" on each side of the door). 3. Water Closets. Water closets shall comply with Section 1134.7. 4. Lavatories, Vanities, Mirrors and Towel Fixtures. Lavatories, vanities, mirrors and towel fixtures shall comply with 1134A.8. 5. Strike Edge Maneuvering Space. Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and exit. 6. Accessible Switches, Outlets & Controls. Switches, outlets & controls shall comply with Sec. 1142A. 67. 1134A.4 Sufficient Maneuvering Space. Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and exit. Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30" x 48" within the room. The clear maneuvering space shall allow the user to position a wheelchair or other mobility aid clear of the path of the door as it is closed and to permit use of fixtures. Doors may swing into the required clear space at any fixture when a clear maneuvering space is provided outside the swing arc of the door so it can be closed. Maneuvering spaces may include and knee space or toe space available below bathroom fixtures. 68. 1134A.5 Bathtubs. Bathtubs required to be accessible shall comply with this section. a) Floor Space. There shall be a minimum clear floor space 48" parallel by 30" perpendicular to the side of a bathtub or bathtub-shower combination (measured from the foot or drain end of the bathtub) to provide for the maneuvering of a wheelchair and transfer to and from the bathing facilities. The area under the lavatory may be included in the clear floor space provided the knee and toe space comply with Sec. 1134A.8. Cabinets under lavatories and toilets shall not encroach into the clear floor space. b) Reinforced Walls for Grab Bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars. Where a bathtub is installed with surrounding walls, grab bar reinforcement shall be located on each end of the bathtub, 32" to 38" above the floor, extending a minimum of 24" from the front edge of the bathtub toward the back wall of the bathtub. The grab bar reinforcement shall be a minimum of 6" nominal in height. Grab bar reinforcement shall be installed on the back wall of the bathtub a maximum a 6" above the bathtub rim extending upward to at least 38" above the floor. Grab bar backing shall be installed horizontally to permit the installation of a 48" grab bar with each end a maximum of 6" from the end walls of the bathtub. The grab bar reinforcement shall be a min of 6" nominal in height. c) Bathtub Controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate controls and operation mechanisms shall be no greater than 5 lbs-force. Lever operated, push- type and electronically controlled mechanisms are examples of acceptable designs. CARLSBAD PC16-0054 SEPT.6,2016 69. 1134A.7 Water Closets. Water closets in accessible baths/ powder rooms shall comply with this section. a) Floor Space. The water closet shall be located in a space a min of 48" in clear width with 36" minimum clear space provided in front of the water closet. This space may include maneuverable space under a lavatory, if provided and arranged so as not to impede access. Exception: The 48" clear width may be reduced to 36" for lavatories and cabinets located immediately adjacent to a water closet which extend no more than 24" in depth. b) Water closets shall be located within bathrooms in a manner that a grab bar to be installed on one side of the fixture. The centerline of the water closet shall be 17" to 18" from a grab bar wall. In locations where water closets are adjacent to non-grab bar walls, the centerline of the fixture shall be a minimum of 18" from the obstacle. The other (non grab bar) side of the water closet shall be a minimum of 18" from the obstacle. c) Reinforced Walls for Grab Bars. Where the water closet is not placed adjacent to a side wall, the bathroom shall have provisions for installation of fioor mounted, foldaway, or similar alternative grab bars. Where the water closet is placed adjacent to a side wall, reinforcement is installed at the back; it shall be installed between 32" and 38" above the fioor. The grab bar reinforcement shall be a minimum of 6" nominal in height. d) Seat Height. The minimum height of water closet seats shall be 15" above the fioor. e) Water Closet Controls. Water closet Controls shall be mounted no more than 44" above the fioor. The force required to activate controls shall be no greater than 5-lbs-force. 70. 1134A.8 Lavatories, Vanities, Mirrors and Towel Fixtures. Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory. Where mirrors and towel fixtures are provided, at least one of each shall be accessible. End a) Location. Vanities and Lavatories shall be installed with the centerline of the fixture a min of 18" horizontally from an adjoining wall or fixture to allow for forward approach. When parallel approach is provided, lavatories shall be installed with the centerline of the fixture a minimum of 24" horizontally from an adjoining wall or fixture. The top of the fixture rim shall be a maximum of 34" above the finished door. b) Floor Space. A clear maneuvering space at least 30" by 48" shall be provided at lavatories and shall be centered on the lavatory. c) Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair & the lavatory cabinets are designed with adaptable knee & toe space. d) Knee and Toe Space. Knee and toe space shall be provided as follows: i) The knee space shall be at least 30" wide and 8" deep. ii) The knee space shall be at least 29" high at the front face and reducing to not less than 27" at a point 8" back from the front edge. iii) The knee and toe space required in this section shall be provided by one of the following: a) The space beneath the lavatory shall be left clear and unobstructed. b) Any cabinet beneath the lavatory shall be removable without the use of specialized knowledge or specialized tools or, c) Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. iv) The toe space required in this section shall be provided as follows: a) Shall be at least 30" wide and centered on the lavatory. b) Shall be at least 17" deep, measured from the front edge. c) Shall be at least 9" high from the fioor. e) Finished Floor. The finished fioor beneath the lavatory shall be extended to the wall. I) Plumbing Protection. Hot water and drain pipes exposed under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. g) Lavatory Faucet Controls. Faucet controls and operation mechanism shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate controls shall be no greater then 5-lbs force. Lever operated. Push-type and electronically controlled mechanisms are examples of acceptable designs. Self closing valves are allowed if the faucet remains open min. 10 seconds. h) Mirrors and Towel Fixtures. Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40" from the fioor. CARLSBAD PC16-0054 SEPT.6,2016 ------------··----- [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PLAN CHECK NO.: PC16-0054 PREPARED BY: ALI SADRE, S.E. DATE: SEPT. 6, 2016 BUILDING ADDRESS: 2262 AVENIDA MAGNIFICA BUILDING OCCUPANCY: R2/U; V-B & V-A BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier KITCHEN/BATH REMODEL & MINOR STUC. CHANGES(@ $25K/UNIT IN 450-UNITS) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance Bldg. Permit Fee by Ordinance .] Plan Check Fee by Ordinance -.,,,;;, ] Type of Review: Complete Review D Repetitive Fee I iJ Repeats Comments: D Other 0 Hourly EsGII Fee Reg. VALUE ($) Mod. 11,250,000 $23,931.01 j $15,555.161 D Structural Only $13,401.371 Sheet 1 of 1 macvalue.doc + «'';' ~· CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 8-25-16 PROJECT NAME: PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.c:.=irlsb;:idc:;:i.r1ov PLAN CHECK NO: PC 16-54 SET#: 1 ADDRESS: 2262 Avenida Magnifica APN: [8] This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required D Yes 1:8:J No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the Issuance of a building permit. Resubmitted plans should Include corrections from all divisions. 0 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: mcarnlghan@musserarchltects.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 ~ Chris Sexton D Chris Glassen D Greg Ryan 76()-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christo~her.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca_,gg_~ D Gina Ruiz D ValRay Marshall D Cindy Wong 76()-602-4675 760-602-27 41 760-602-4662 Gina.Ruiz@carlsbadca.gov Va1Ray.Marsha1l@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D Veronica Morones D Linda Ontiveros D Dominic Fieri 760-602-4619 760-602-2773 760-602-4664 Veronica.Moron11s~~;:irl~!1<1!!~;:i.gQv Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: interior remodel of apartment units -new cabinets, appliances, relocate outlets, new closet and change bathroom layouts. /1 I MUSSER:ARCHITECTS, INC. PLAN CHECK CORRECTION RESPONSES DATE: 10/05/2016 PROJECT NAME: THE RESERVES AT CARLSBAD-APARTMENT RENOVATION PROJECT NUMBER: 15042 PLAN CHECK NUMBER: PC16-0054 PLAN CHECKER: ALI SADRE ( ESGIL) CORRECTION ITEM AND RESPONSE ARCHITECTURAL DESIGN PLAN CHANGES MADE TO "F" UNIT FROM 1 ST SUBMITTAL. 1. Detail reference corrected 2. Reference was corrected on sheet A-Bl .01 BLDG# 3 3. Detail reference has been corrected. 4. The accessibility reference has been noted that project was built before 1991 and is not a covered project. 5. The accessible units were not required under the CBC and were provide originally as accommodation units for marketing reasons. The previously provided accessibility was maintained. 6. Note added , will apply to public spaces ( leasing office access ). 7. Key notes added to unit plans for existing shear I bearing walls within units. FIRE RATED CONSTRUCTION 8. Sheets AD-B6.0 and AD-B6.2 are added for details. 9. Sheets AD-B6.0 and AD-B6.2 are added for details. I 0. Reference detail A2 II AD-B6.2 keyed to walls on unit plans. This has separation standards. 11. Note added to plans. 12. No fans or vents penetrating assemblies are added. 13. No ducts are being added or modified on this project. 14. Detail added (A21/AD-B6.2) for standards 15. Keynote changed to require I-hr rated access panel 16. No ductwork this project at party walls SOUND TRANSMISSION 17. Details added at Sheets AD-B6.0 and AD-B6.2 for wall I floor I penetration requirements. MISC. 18. Average unit cost -$ 3,500.00 3190 Airport Loop Drive, Suite F, Costa Mesa, CA 92626 Phone: (714) 241-8944 Fax: (714) 241-8797 PlanCheckResponse.doc //1 //1. , t/ I// /1 I MUSSER:ARCHITECTS, INC. STRUCTURAL 19. Header size given at new doors on unit plans. 20. Typical non-bearing wall detail keyed on plans , no bearing walls changed. 21. Existing shear walls noted on unit plans , no changes at shear walls. 22. No changes to existing structural elements. 23. Noted ADDITIONAL ITEMS SEE A TT ACHED RESPONSE FROM MEP 30. keynote #4 modified on architectural plans for low flow fixtures. 31. detail is schematic, no platform in units. 35. washer dryer in "B" units was existing , provide by tenant. Connections were existing, no changes. 36. no HV AC systems in these units. No changes to existing exhaust ducting. 3 7. existing ducting at washer dryer locations in "B" unit THIS PROJECT NOT COVERED UNDER CBC 1 lA OR 118 3190 Airport Loop Drive, Suite F, Costa Mesa, CA 92626 Phone: (714) 241-8944 Fax: (714) 241-8797 PlanCheckResponse.doc September 27, 2016 SOUTHWEST GROUP Engineering Consultants, Inc. 9201 Research Dr., Irvine, California 92618 Tel: (949) 387-8989 Fax: (949) 387-3993 City of Carlsbad Jurisdiction Carlsbad 0054 PLAN CHECK NO.: SUBJECT: PC16 The Reserve Apartment at Carlsbad 2262 A VENIDA MAGNIFICA CARLSBAD, CA 92008 The following are the response to the plan check comments for limited work (Kitchen Area). The items added or changed on the plans are indicated with clouds noted as Delta I. ELECTRICAL AND ENERGY PLAN CHECK CORRECTIONS PLAN REVIEWER: Eric Jensen Item 26: Complied. Scope of Work included on sheet EO. l Item 27: Complied. Kitchen countertop receptacle outlets has been added. See Unit Plan Sheets E3.l thru E3.5. Item 28: Complied. Panelboard faces has been specified for each floor plan. See Unit Plan Sheets E3.l thru E3.5. PLUMBING (2013 CALIFORNIA PLUMBING CODE) PLAN REVIEWER: Glen Adamek Item 30: Complied. See G at "Installation Notes" on sheet PO. I. Item 31: Revised Detail 2 "Electric Water Heater". See sheet P0.2. Item 32: Revised Detail 2 "Electric Water Heater". See sheet PO.I, P0.2 and sheet P3.l thru P3.3. Item 33: Revised Detail 2 "Electric Water Heater". See sheet PO. I, P0.2 and sheet P3. l thru P3.3. Item 34: There is a Central Water Heater System for each building on phase II that include those plans F, G, J and H. See "Plumbing General Notes" on sheet P3.4 and P3.5. Item 35: Complied. See complete set for the Reserve project.