Loading...
HomeMy WebLinkAbout2270 CAMINO VIDA ROBLE; 9 | 10 | 13; CB901158; PermitBUILDING PERMIT 03/13/91 10:31 Page 1 of 1 Job Address: 2270 Permit Type: Parcel No: Valuation: CAMINO VIDA ROBLE INDUSTRIAL TENANT IMPROVEMENT 213-050-47-00 0 Str: Permit No: Project No: Development No: Fl: Ste: Construction Type: NEW Occupancy Group: Class Description: STE 13/ADD 4188 SF SHIP & : REDUCE MEZZ 292 SF Code; STOR Appl/Ownr FORBURGER, R P O BOX 59 RANCHO SANTA FE, *** Fees Required *** CA 92067 *** Stats Applied Apr/Issue Validated By 619-756-3739 Fees Collected & Credits CB901158 A9001262 VOID 07/09/90 CD *** Fees: 427.00 Adjustments: .00 Total Fees: 427.00 Fee description Total Credits: Total Payments: Balance Due: Units Fee/Unit .00 168.00 259.00 Ext fee Data Building Permit Plan Check * BUILDING TOTAL 259.00 168.00 427.00 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (eia) «B-ii6i 1. PERMIT TYPEA - Q COMMERCIALd"EWQTENANT IMPROVEMENT B - ^INDUSTRIAL D"E" QTENAMT IMPROVEMENT C - [^RESIDENTIAL DAPARTMENT DCONDO QSINGLE FAMILY DWELLING Q ADD IT ION/ALTERATION DDUPLEX DEMOLITION DKELOCATION D"°8"-E HOME QELECTRICAL DMECHAN1CAL DP°°L QSPA DETAINING WALL D50LAR 2. PROJECT INFORMATION PLAN CHECK No. EST. VAL PLAN OC DEPOSIT VALID. BY DATE *7 FOR OFFICE USE ONLY Bui Idin ross Streets q -' LEGAL DESCRIPTION Subdivision Name/Number Phase No. CHECK BELOW IF SUBMITTED: D 2 Energy Calcs Dj! Structural Calcs []"] 2 Soi Is Report Ql Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE 3. CONTACT PERSON . P-*O R. £b LJ - ADDRESS f, O . (3 ^5 X -> T STATECA ZIP CODE CJ ^Q £ 7 DAT TELEPHONE T S 4 r4. APPLICANT DECENT FOR CONTRACTOR ADDRESS QOWNER D AGENT FOR OWNER DAY TELEPHONE 5. PROPERTY OWNE A .. ADDRESS *3i2~~J ZIP CODE^f *Z d QTENANT ^ DAY TELEPHONE ^ 3 ^S ~ <0 O 7 6. CONTRACTOR NAME ADDRESS ZIP CODE DAY TELEPHONE LICENSE CLASS CITY BUSINESS LIC. # TITLE B U ADDRESS ZIP COOEQ DAY TELEPHONE STATE LIC. # 7. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO.EXPIRATION DATE Certificate of Exemption: ] certify that in the performance of the work for which this pernti t is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE 8. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q| I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.}. n I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES Quo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES DNO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES Quo IF AHY OF THE ANSWERS ARE TES, A FIMAL CERTIFICATE OF OCCUPANCY MAY MOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AMD THE AIR POLLUTION CONTROL DISTRICT- 9. CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE I certify that 1 have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY UAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANT'S SIGNATURE OWNER Q CONTRACTOR PHONE APPROVED BT; DATE; WHITE: File YELLOW: Applicant PINK: Finance ESG1L CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560-1468 DATE: JURISDICTION: PLAN CHECK NO: PROJECT ADDRESS: PROJECT NAME: -7/AS /?6> CARLSBAD ?0-SET: Z ~i- ~7 O iy n r r [^APPLICANT FILE COPY QUPS QDESIGNER , i'of /? The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified __ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: "7 Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: _ Date contacted: REMARKS: Telephone # By Enclosures ESGIL CORPORATION D GA D AA D VW Q DM FLAN CHECK NO.: FLAN CORRECTION SHEET TENANT IMPROVEMENT Date plans received by jurisdiction: JURISDICTION: CARLSBAD TO: PROJECT DATA OCCUPANCY: BUILDING 0SE: TYPE OF CONSTRUCTION: ACTUAL AREA: ALLOWABLE AREA: STORIES: HEIGHT: SPRINKLERS: OCCUPANT LOAD: REMARKS: ,$ t Date plans received by Esgil Corporation: "//iO Date initial plan check completed: > By; P / Applicant contact person: Tel. FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Code sections cited are based on the 1988 UBC. The circled items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, note on this list for a_.__copy) where each correction item has been addressed, i.e.. plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. LIST NO. 56 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC 4.. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-U68. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(d). Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 302(d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section i02. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. X- On the first sheet of the plans indicate: Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located. Provide a note on the plans indicating if any hazardous materials will be stored and/or used vitMn. the building which exceed the quantities listed in UBC Tables 9-A and 9-B. A complete description of the activities and processes that will occur in this tenant spaceshould be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible. The building official may re*quire a technical report to identify and develop methods of protection from hazardous materials. Section 901(f). If control areas are used for exceeding the exempt amounts o£ hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC -and UPC and 1987 NEC. Sf^i-ST ( S X Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or ijnproved. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and, provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls. 12/29/89 f. Identify existing walls to be removed, existing walls to remain and proposed new wal Is. Identify bearing walls, non-bearing walls, and shear walls. Provide a section view of all new interior partitions. Show: (a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". (b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). (c) Wall sheathing material and details of attachment (size - "and spacing of fasteners). (d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 510(b). Note on the plans: "All interior finishes must comply with Chapter 42 of the UBC". Specify "Class flame spread rating (minimum) for ." Lateral bracing for suspended ceiling roust be provided. (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No. 12. gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling. A strut (adequate to resist the vertical component from lateral loads) fastened to the main runner shall be extended to and fastened to the structural members of the roof or floor above. These horizontal restraint points shall be placed 12 feet o.c, in, both directions with the first point within 6 feet of each wall. Attachment of restraint wires to the structure above shall be adequate for the load imposed. UBC Standard 47-18. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceijlng, and__flgox jiboye. so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.}. Section 2516(f). In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the c_ei_ling__ and roof above so that no concealed space exceeds 3,000 s.f, and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 2516(f). 29*. ""Storage area's exceeding 1000 sq. ft. in / connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet. Section 3802(c). 31.) The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24, Part 2. VI. The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the - strike edge for interior doors. Section 2-3304, Title 24. S3. Specify lever-type hardware for passage doors on. floors accessible to the disabled. Section 2-3304, Title 24. J4. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men. and women. If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 705. VS. In areas where the occupant load exceeds , f two exits are required. See . Table 33-A. 2/15/90 4. The minimum rating of 100 amperes. a service disconnect is 105. The minimum size conductor to receptacles and ' lighting fixtures in commercial and industrial buildings shall be #12 Cu. 106. AC(BX) cable is not allowed in group A, B, E, H / and I occupancies, (see Ord. for exception) MISCKLLAHEOPS Please see that follow. additional corrections or remarks 108J To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 109.) Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No MOTE: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall. They are provided here as a courtesy to assist designers in developing the project documents. All applicable provisions may not necessarily be included. Please direct any questions regarding interpretations of these provisions to the local Fire Departoent. Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction. Section 3305(g)l. s/22. Where exit signs are required by Section 3314(a), approved and listed internally, externally or self-illuminated low-level exit signs complying with Section 3314 shall be required. The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level. For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door. Such signs shall be of a type which is perceptible to the sense of touch. Section 3314(e). S-,Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking. Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level. Such marking shall be of a type which is perceptible to the sense of touch. Section 3314(f). 4. Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38. Section 505(e)6. EXCEPTION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation vails in lieu of automatic fire-sprinkler protection. In educational occupancies, storage and janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). Section 1807 should be reviewed for all high- rise buildings. The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. ¥• If. J.A emergency varning systems are required, they shall activate a means of warning the hearing impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact P at Esgil Corporation Thank you. Enclosures: 1.. 2. 2/28/90 Oft . r ? r ;v^ /t f f ^ fj^e. K.. 7 7) v6,S i*_~n /2-.£'CtaC/4 7> Q 5T M _'C P,Z- V\ \ o ft. Trt-O- P^O^tcr S^(~ /g_g-^f^g7 t'-Clft. /£- ; S fc , Cs07 O __ _ ^,_, ^ ^ r •> QVL/6'XV^-t. V 4 — UIt O 3 OU .-4 v. c C 4 -••3 O OG ~< - >4 I W M (IX 4 C -i£ « *J Ois v m v it-• »* o. o4 4 U LiO > U 3 « >. LJ ~4j: v -»o, A a » ^ Svi V U C PCO V C O-« ll —I -4n u TJ M 4 — -* 4~. il > w3 O -1pi rt u -«v no.-*vt o U C *4ti> uU CU ftl " C 4Ju -3-• ,c • ti•• 4 w a >*j > -« -H -«o -* > fi 4 S3 « >cr e -o 00^*0c -• a -• cc ** E -a c -4 -J3 <- •3 v«c u 4 0 U VC U4 U < a. jsO* E *JO O 0« o a •O Ju ug g aO.< v a t* c a n O rt-i • 4 ox •H Uo ea. oa -*5 UUW V O VIVIV« -ac oo u o•o oc -• C V« -3 ••< OU U f o on c e 4 « "4rt ti >« -.4 O •U O *J> VI — 4U O Vi £ — ** - s n a0 E0 v -• X w a pi v« O -« 4 S o. nE C>4 OU U4 vi *>o . j: c 3o o - SO 0. •a vio o O JJ V| -H U*J —I « gn .0 wi»4 « 3-* iJ a ov. c -aO ft) Oo *—-o oJ3 V "4*« W > X—t O «S 3 W CO tf Q. v,"• « 4O ki O V) n -ao E -av c * o v t> a LIi 0-4 fc> Vl^ OS O LI e4 o -« Q. •3p-4 ^ "4 U3 aJ3 O. >f -O -4 Vu o a yo -o a. -4vi c o v«4 9 J= VIW vi 4 O i °A kl4 vj • 4 U a u« c -i 3 " 8 3 O4Ju -oc< ? 1-» a•O M TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction ' Plan Check No. References to section numbers with prefix "2" are to Title 24, California Code of Regulations, Part 2 (California Building Code). Prefix "3" is for Part 3 {California Electrical Code). Prefix "V1 is for Part 5 (California Plumbing Code). Exemptions claioed for any item shall be requested in writing and shall include all data needed to determine "unreasonable hardship" as described in Section 2-422. SITE DEVELOPMENT I. HANDICAPPED PARKING SPACES a. Provide ^handicapped spaces, 2-7102(b) b. Space shall be so located that handicapped persons are not compelled to wheel or walk behind parked cars other than his/her own. 2-7102(c) c. Parking space shall be a minimm of 9 ft.xlS ft. with adjacent marked 5 ft. loading zone. Double space shall be 23 ft. wide. Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle- 2-7102(c). d. Maximum slope of parking surface in any direction shall not exceed 1/4" per foot. 2-7102(e). e. Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and also duplicated on parking surface (symbol to be 36"x36lt and painted at the back of the parking stall). 2-7102(f) f. Entrance to parking area (or at each stall) shall have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away. 2-7102(f) g. Entrance to and vertical clearance within accessible level of parking structure shall be 8 ft. 2 in. to any structural member, duct or pipe. 2-7102(g) 2. CURB RAMPS a. Curb ramps shall ba located wherever pedestrian path crosses curb. (2- 7103(a)) b. Curb ramp shall ba 48" rain, width (2- 7103(b)) with maximum slope of 1 in 12. 2-7103(d) c. A level 48" min. depth landijig is required at top of curb ramps over entire curb ranp width. 2-7103(d) d. If no landing is provided, the slope of flared sides shall not exceed 1 in 12.2-7103(d) e. Surface, is to be slip contrasting finish sidewalk. 2-7103(f) resistant and a from adjacent f. Border markings shall be 12" wide of ~ I/4"xl/4" 'grooves, 3/4" apart, located at top and sides. 2-7103(h) 3. WALKS a. Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-7101(a) b. Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec. 2-3307. 2-3325(c) c. Walk width, shall be 48" minimum, shall have slip-resistant surfaces. 2-3325(a) and d. The maximum cross slope shall not exceed 1/4" per foot. 2-3325(a)3 e. Gratings are not possible. ~2-3325(b) allowed whenever f. At each gate or door a 60"x60" level area is required when the gate swings toward the walk. 2-3325(e) g. A 48"x44" deep level area is required when the gate swings away from the walk. 2-3325(e) h. A 24" clear space is required at strike side of gate or door. 2-3325(e) 4. PEDESTRIAN RAMPS a. A path of travel with a slope greater than 1 in 20 shall be considered a ramp. 2-3307(a) b. The maximum slope shall be 1 in 12. 2-3307(c.l) c. The width shall ba 48" minimum. A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more* Group R Occupancies may be 36" when the occupant load is 50 or less. 2- 3307(b.l) d. The surface of ramps shall be slip- resistant. 2-3307(g) e. A 60" intermediate landing is required at maximum elevation change of 30" and 72" landing at each change of direction (over 30 degrees). 2-3307(d,l) f. Landings are required at top and bottom of ramps. 2-3307(d.l) g. Bottom landing shall be minimum of 72" in the direction of travel. Fig. 2-33- 11A h. Top landing shall be 60" x 60" minimum. 2-3307(d.l) i. When door swings onto top landing, minimum depth of landing required is door width plus 42". 2-3307(d.l.) j. Top landing shall have 60" min. width when door swings onto the landing, with 24" on strike side of door at exterior ramp, or 18" at interior ramp. 2-3307(d.l) k. Ramp handrails are required on each side of ramp, when slope exceeds 1 in 15. 2- 3307(e.l) 1. Ramp handrails shall be continuous, located 30"-3V in height above ramp surface, with 12" extensions beyond top and bottom, and the ends returned. 2-3307(e.l) m. Handrails shall be 1-1/4" to 2" cross section, spaced minimum of 1-1/2" from wall. 2-3307(e-l) n. A 2" high curb or wheel guide rail centered 3" i 1" above ramp surface is required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length. 2-3307(h.l) 5. SPECIAL ACCESS LIFTS a. Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural design and safeguards axe as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health. 2-5107(a) . b. The lift platform shall be o£ sufficient size to accommodate a wheelchair (30"x48"). 2-5107(a) c. There shall be a level and clear floor area or landing (60"x60") at each level for access to the lift. 2-5107(a) 6. HAZARDS a. Provide 80" headroom from walkway surface to any overhanging obstruction. 2-3326(b) b. Headroom of 80" minimum shall be maintained for walks, corridors, aisles, etc. 2-522(f) c. Protruding objects with leading edges between 27" and 80" above finished floor shall not protrude more than 4" into walks, corridors, etc. 2-522(f) d. Free standing objects mounted on posts between 27" and 80" above the floor may project a maximum of 12". 2-522(f) e. Abrupt ' changes in level exceeding 4" adjacent to walks, except between walks and adjacent streets or drives, shall be identified by 6" high warning curbs above t walk surfa.ce. 2-3326(a) ENTRANCES AND CIRCULATICW 7. ENTRANCES, DOORS, VESTIBULES AND CORRIDORS a. All primary entrances to buildings shall be accessible to the handicapped. 2-3301(f) b. All required passage doors shall have 32" clear opening at 90 degrees (36" door). 2-3304(f) c. At least one of a pair of doors shall meet the minimum 32" clear entrance width requirement. 2-3304(f) d. Threshold shall be no higher than 1/2" above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more than 1/4". 3304(1.1) e. Exterior level landing may slope up to 1/4" per - foot in any direction for surface drainage. 2-413 f. Door hardware shall be of the lever or push type, mounted 30" to 44" above the floor and be operable with a maximum effort of 8.5 Ibs. for exterior doors and 5 Ibs. for interior doors. 2-3304(c), 2- 3304(i.2) g. The lower 10" of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304(1.3) h. Building entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan. The symbol shall be a white figure on blue background. 2-522(b) i. At turnstile, provide an access gate, 32" clear width opening, within 30 feet of turnstile. 2-3304(1.4) j. There shall be a clear area on each side of door, 60" deep in direction of door swing and 44" deep in opposite direction of door swing. 2-3304(1.1) k. Width of clear area on the swing side of the door shall extend 2V past strike jamb for exterior doors and 18" past strike jamb for interior doors. 2-3304(i.l) The space between two consecutive doors (vestibule) shall provide a minimal of 48" clear depth between the open doorand a second closed door.Doors in a series at a vestibule shall swing in the same direction, or away from the space between them. 2-3304(i,l) For corridors, over _200 feet long, see special requirements of Sec. 2-3305(b)2. 8. FLOORS a. Floors of a given story shall be a common level throughout or shal1 be connected by pedestrian ramps, passenger elevators, or s pecial access lifts. 2-522(e) 9. STAIRWAYS NOTE: Only applies vhere disabled access is provided or required to other levels. a. Treads shall have smooth, rounded exposed edges and be slip resistant. 2- 3306(s) b. Nosing shall not project more than 1-1/2 inches past face of the riser below. 2-3306(s) c. Risers shall be sufficiently solid. 2-3306(s) d. The upper approach and lower tread of each flight of stairs shall be marked with a contrasting colored strip 2" in width. 2-3306(r) e. On exterior stairs, each tread shall be marked as noted above. 2-3306(r) f. Handrails are required on each side of stairway. 2-3306 g. Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread, width beyond bottom nosing and returned to wall/newel post. 2-3306(j.l). h. Handrails shall be 1-1/4" to 2" in gripping cross section and 1-1/2" clear of wall. 2-3306(j.l) i. Approved stairway identification signs shall be located at each floor level in all enclosed stairways in buildings two or more stories in height. The sign shall identify the stairway, indicate whether there is roof access, the floor level, and the upper and lower terminus of the stairway. The information shall be presented using raised Arabic minerals and raised braille symbols which conforn to Section 522(b)3. The sign shall be located approximately 5 feet above the floor landing immediately adjacent to the door on the strike side. Signs shall comply with requirements of U.B.C. Standard No. 33-2. 1CK ELEVATORS a. Provide clear inside elevator car dimensions as required by U.B.C. Section 5103(d) 6 and litle Ik 2-5103(d.l). 1. At least one elevator in buildings k or more stories in height: 80" by 54", with a 42-inch -side slide door. Applies only to: high-rise buildings, A/E/I occupancies, State-owned buildings, residential care homes, hotels, motels, apartments and condominiums. 2. Elevator in buildings more than two stories or buildings where disabled access is required to upper level(s): 68" by 54", with a minimum clear door width of 36". 3. Elevators other than in (b) above serving less than 50 occupants shall have a minimum inside platform of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches. b. Raised Braille markings and Arabic numerals are required on control buttons and door jambs. 2-5103(d.l) 5AHHARY. FACTLTTTES 11. TOILET FACILITIES ACCESS a. When located on accessible floors, sanitary facilities shall be made accessible to physically handicapped. (2-511.l(a)) b. Doorways ' shall have 32" minimum clear opening width. 2-511.1 c. There shall be a level area with 60" clear depth in the direction of the door swing, and a level area with 44" clear depth in opposite direction of door swing. 2-511.l(a) 12, MULTIPLE ACCOMMODATION TOILET FACILITIES a. Provide clear area 60" diameter x 27" high - or clear space 56" x 63" x 27" high. 2-511.l(a) b. Doors (other than handicap compartment) are not to encroach more than 12" into above mentioned clear space. 2-511. l(a) c. Provide a 28" clear space between water closet and fixture or 32" clear space between water closet and wall. 2-511. l(a) d. A 48" long clear space is required in front of water closet. A 60" clear space is required vhen the toilet compartment has a side door, 2-511. l(a) e. Water closet compartment door to provide 32" clear width for end entry and 3V1 clear, width for side entry. Door to be self-closing. 2-511. l(a) 13. SINGLE ACCOMMODATION TOILET FACILITIES a. Water closet shall be located 28" from a fixture or 32" from a wall. 2-511. l(a) b. Minimum clear space in front of water closet shall be 48". 2-511. l(a) c. In an existing building, a single accommodation toilet facility may have a space 36" wide X 48 " long in front of water closet. 2-511. l(a) 14. GRAB BARS AI WATER CLOSET a. One at side 42" long extending 24" in front of water closet; one at rear 36" long centered on water closet ; both mounted 33" above floor. Where a tank- type toilet is used, grab bar may be as high as 36". 2-511. l(a) b. Ears shall be 1-1/4" to 1-1/2" in diameter with 1-1/2" clearance to wall. c. Bar fasteners- and mounting support shall be able to withstand 250 Ibs./ft. in bending, shear and tension. 2-511. l(a) 15. WATER CLOSE! a. Height of water closet seat shall be 17" to 19" above floor. 5-1502 b. Controls shall be ' operable with one hand, and shall not require tight grasping, pinching or twisting of the wrist. 5-1502 c. Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor. 5-1502 d. Hie forca required to activate controls shall be no greater than 5 pounds force. 5-1502 16. URINALS . . . - a. Where urinals are provided, the rim of at least one shall project 14" from the wall and be located 17" maximum above floor. 5-l503(a) b. The force required to activate the flush valve shall be 5 Ibs. maximum and located 44" maximum above floor. 5-1503(b) c. Provide 30" x 48" clear floor Space for forward approach. 2-511.l(b) 17, LAVATORIES a. Provide, 30" x 48" clear floor space for ,*— forward approach. Said clear floor space may include knee and toe space under lavatory described below. 1-511.l(b) b. Provide clear space beneath lavatories 29" high by 30" wide by 8" deep at top and 9" high by 30" wide by 17" deep at bottom from front of lavatory (toe space). The maximum counter surface height should be 34". 5-1504(a) c. Hot water and drain pipes lavatories shall be insulated. 5-1504(b) under d. Faucet controls and operating mechanism (operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 Ibs. 5-1504(c) e. If self-closing valves are used, they shall remain open for at least 10 seconds. 5-1504(c) 18. TOILET ROOM ACCESSORIES a. Mirror bottom edge shall be located 40" maximum above floor. 2-511.l(b) b. Toilet tissue dispensers shall be mounted within 12" from the front edge of toilet seat. 2-511.100 c. Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc.) shall be within 40" of floor. 2-511.100 19. SANITARY FACILITIES IDENTIFICATION a. On doorways leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" diameter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color. Unisex facilities shall be identified by the circle with the triangle superimposed within the circle. 2-511.l(a) 20. BATHING FACILITIES a. One such facility shall comply when provided for the public, clients or employees. 2-511.1(a) b. Shower compartment shall be 42" wide, 48" deep, with a 36" wide entrance. 2-511.l(a) c. Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec. 2-511a-9, 5-1505 and 5-1506, i.e., folding seat, flexible shower hose, etc. GENERAL KEQOIKEMEHIS 21. DRINKING FOUNTAIN a. Drinking fountains shall be within alcoves. The alcove shall be not less than 32" vide by 18" deep. 2-511.l(c) b. When the enforcing agency determines that it would create an unreasonable hardship to locate the water fountain in an alcove, the water fountain may project into the path of travel, and the path of travel shall be identifiable to the blind as follows: (1.) The surface of the path of travel at the water fountain shall be textured so that it is clearly identifiable by a blind person using a cane. The minimum textured area shall extend from the wall supporting the water fountain to 1 foot beyond the front edge of the water fountain and shall extend 1 foot beyond each side of the water fountain, or (2.) Wing vails shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the path of travel. Also, there shall be a. minimum of 32 inches clear between the wing walls. c. Note on the plans that drinking fountain shall conform to requirements of Sec. 2-511c and 5-1507. 22. PUBLIC TELEPHONE a. Provide space 30" x US" for forward orparallel approach to telephone. 2-511.l(d) b. Note on the plans that public telephone shall conform to requirements of Sec. 2-511.l(d). 23. ELECTRICAL REQUIREMENTS a. 15, 20 and 30 amp receptacle outlets shall be installed not less than 12" above floor. 3-210-50(e) b. Center of witches shall be located not less than 36" nor more than 48" above the floor. 3-380-8(c) PLUMBING REQUIREMENTS a. Where kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc., the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i.e., use lever- operated, push-type, etc.)- If self- closing valves are used, they shall remain open, for at least 10 seconds. 5-1508 GRDDP A OCCUPANCY 25. AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC. a. Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance. 2-611(b) b. This structure requires _ wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(b) c. Each wheelchair space shall be 60" x 30" and level. 2-611(b) d. When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(b) e. This structure requires _ seats for semi-ambulant persons. Clear leg space shall be at least 24". 2-611(b) f. Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible. 2-611(b) 26. STADIUMS, GRANDSTANDS, BLEACHERS, PAVILIONS, GYMNASIUMS a. This structure requires _ wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(c) b. When the seating capacity exceeds 300, the wheelchair spaces shall be in more than ona location. 2-611(c) c. Ticket booths must be accessible from both sides. 2-611(c) d. Participation areas such as ball courts, exercise rooms , tracks , and c lubrooms must be accessible. 2-61l(c) e. Spectator and participant sanitary and locker facilities must conform to the requirements of Chapter 2-5. 2-611(c) 7.7. DINING, BANQUET AND BAR FACILITIES a. Access shall be provided at primary entrances. 2-611(d) b. Wheelchair access shall be provided to all areas where each type of functional activity occurs. 2-611(d) c. This facility requires wheelchair seating spaces.Z-61l(d) d. At least one wheelchair seating space shall be provided for each dining, banquet and bar area. 2-611(d) e. Access to wheelchair seating spaces shall- be provided by ~36" minimum clear width main aisles. 2-611(d) f. Cafeteria line aisles shall be a minimum of 36" clear width. 2-611(d) g. Access to food preparation areas shall comply with provis ions for entrance doors and doorways contained.in Section 2-330^. 2-611(d) h. . Restrooms and powder rooms shall conform to the requirements in Section 2-511. 2-611(d) 28. RELIGIOUS FACILITIES a. Sanctuary areas shall be accessible. 2- wheelchair seatingb. Provide spaces in the sanctuary. Use Section 2- 2-611(e) c . Provide wheelchair access to raised platforms, choir rooms, choir lofts, performing areas and other similar areas. 2-611(e) d. Assembly areas along with enclosed and unenclosed platforms and stages shall be made accessible. 2-611(e) e. Sanitary facilities shall conform to the requirements of Chapter 2-5. 2-611(e) 29. ASSISTIVE-LISTENING DEVICES a. b. Assembly areas with permanently installed public address systems (other than exclusively for paging or background music), shall* provide assistive-listening systems for people with hearing impairments. 2-611(f) Since the capacity of the assembly area exceeds 99, this facility requires personal receivers to be available on request. 2-611(f) c. If the system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the performing area. d. A sign shall be posted in a prominent place indicating the availability of assistive-listening devices. The sign shall include the international symbol of deafness . and wording that states "Assistive-listening System Available". GROW B OCCUPANCY. KEQOIMHENTS 30. Group B occupancies used for assemblypurposes but having an occupant load of lessthan 50 shall conform to all the requirements for Group A occupancies covered in Section 2-611. 2-712(d) 31. SALES FACILITIES "*3. General sales, display and office areas together with related toilet rooms must be accessible. 2-712(b) b. Sales employee work stations shall be located on accessible levels. Employee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible. 2-712(b) c. This facility requires stands accessible to handicapped, based check the physically upon 1 for 8 checkstands'or less, 2 for 9 or more. 2- 712(b) d. Where quick check stands are provided, at least one shall be accessible. 2-712(b) e. Check stands shall be made accessible by providing a 36" aisle on the customer side of the stand. 2-712tb) f. Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to "be open at all times for handicapped/physically disabled customers". 2-712(b) 32. FITTING OR DRESSING ROOMS a. Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the physically handicapped. 2-712(b) b. Minimum dimension of room shall be 60" x 60". 2-712(b) c. Bottom of the mirror shall be located within 20" of the floor. 2-712(b) d. Height of clothing hooks shall not be greater than J*8" from the floor. 2-712(b) GROUP H OCCUPANCX REQUIREMENTS 33. a. Accessible sanitation facilities in all Group H Occupancies shall ba provided as specified in Chapter 2-5. 2-913(a) b. Accessible floors and levels shall comply with the requirements specified in Chapter 2-5. 2-913(a) c. Employee work areas shall be accessible by means of a 36-inch minimum aisle width, and a 32-inch minimum clear opening door width. ADDITIONS, AIOIRAHOKS AND REPAIRS TO EXISTING BUHJJIBGS- (Z~UOA.(b)ll) 34. The area of specific addition, alteration and/or repair, shall '"comply with the provisions of Title 24. Additionally: a. The primary entrance to the building and path of travel to the specific area shall be accessible to the handicapped persons. Compliance must be shown, beginning from the existing parking area and leading to the area of alteration. b. Existing restrooms, water fountains, and public telephones which serve said specific area must be shown to be accessible to and functional for handicapped persons. c. Information regarding handicapped accessibility shall be posted in lobby per Sec. 2-522. U/29/89 DOCUMENTATION OF UNREASONABLE HARDSHIP - - - Job Address Plan Check No Owner \ Pate It is requested that the above named project be granted an exceptipn from the requirements of the State of California Title 24 handicappedaccessibility provisions, as specifically noted below: 1. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXEMPTED 2. The cost of all construction without excepted items, is: ._ 3. The impact on financial feasibility of the project, if the requestedexception is not approved is: . » 4. The facility is used by the general public for the purpose of: 5. The exceptions being requested will not penalize handicappedaccessibility as equivalent facilities are available as follows: 6. Exceptions requested, and data provided, by; NAME ' • ADDRESS—: ; : I 'i'KLKPHUNK Department. Use Only Findings and Decision of the Enforcing Official: Signature of Enforcing Official Date HA-1 010190 Date: ~?/(t_ Prepared byi PF Jurisdiction CARLSBAD VALUATION AND PLAN CHECK FEE Bldg. Dept. Esgil PLAN CHECK NO. 20. BUILDING ADDRESS APPLICANT/CONTACT BUILDING OCCUPANCY _ TYPE OF CONSTRUCTION t/f&A: PHONE NO. DESIGNER PHONE CONTRACTOR PHONE BUILDING PORTION TOT Air Conditionine Commercial Residential Res. or Comm. Fire S-orinklers Total Value BUILDING AREA • VALUATION MULTIPLIER '@ 0 @ ' ' VALUE ^s~ i z-s v 1 " Z^-il^ Building Permit Fee Plan Check Fee $ COM MEN TS; SHEET / OF 12/87 BUILDING PLANCHECK ENGINEERING CHECKLIST DATE: 2.5 JTJL SO 0 ITEM COMPLETE PLANCHECK NO. 9O - i I 5 ft O ITEM INCOMPLETE - NEEDS YOUR ACTION1s T C H E C K 2f 2 N D C H E C / K D 3 R D C H E C K 22"? O CAMiNO n-* j r>> KT^BLE- PROJECT ID: LEGAL REQUIREMENTS Site Plan 1. Provide a fully dimensioned si X ITEM SELECTED plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width and dimensioned setbacks. I—1 I—I 2. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. LJ LJ LJ 3^ Provide legal description and Assessors Parcel Number. Discretionary Approval Compliance \/ 4. No Discretionary approvals were required. 5. Project complies with all Engineering Conditions of Approval for Project No. . 6. Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by: Date: Field Review Nl/A 7. Field review completed. No issues raised. 8. Field Review completed. The following issues or discrepancies with the site plan were found: A. Site lacks adequate public improvements. B. Existing drainage improvements not shown or in conflict with site plan. C. Site is served by overhead power lines. D. Grading is required to access site, create pad or provide for ultimate street improvement. FRM0010.DH 08/29/89 Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. Other: Dedication Requirements v 9. No dedication required. .10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8^" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as fol1ows: Dedication completed, Date:.By:. Improvement Requirements .11. No public improvements required. SPECIAL NOTE: Damaged or defective improvements found ad.iacent to building site must be repaired to the satisfaction of the Citv inspector prior to occuoancv. .12. Publi c improvements requi red. Thi s project requi res construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate piancheck process through the Engi neering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: Improvement plans signed, Date:.By:. FRM0010.DH 08/29/89 .13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date By: Grading Requirements 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). 14. No grading required as determined by the information provided on the site plan. 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: By: Miscellaneous Permits v 16. Right-of-Way Permit not required. 17. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the fol 1owi ng: .18. Sewer Permit is not required. .19. Sewer Permit is required. A Sewer Permit is required concurrent with Building Permit issuance. The fee required 1s noted below in the fees section. 20. Industrial Waste Permit 1s not required. FRM0010.DH 08/29/89 .21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Applicantion Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted - Date: By: Fees Required KJ/A 22. Park-in-Lieu Fee Quadrant: _ Fee per Unit: _ Total Fee: . Traffic Impact Fee Fee Per Unit: _ Total Fee: _ 24. Bridge and Thoroughfare Fee Fee per Unit: _ Total Fee: _ M/'pt 25. Public Facilities Fee required. Jir£i_26. Facilities Management Fee Zone: _ Fee: _ 27. Sewer Fees Permit No. _ EDU's Fee: KJffi 28. Sewer Lateral required: Fee: _ _ REMARKS: ENGINEERING AUTHORIZATION TO ISSUE PERMIT FRM0010.0H 08/29/89 dj 41 U 000 ^t It ** -X -M J< .c -c ^:U LJ U PLANNING CHECKLIST Plan Check No. gfc Q0-ll^f> Address 2ttQ COJfo\ HO \J(CJ£L2/2> - r>so -41 tuYut *^«-/o-rv Planner (Name) Type of Project and Use-Or»AJ&h.i Zone Phone 438-1161 Facilities Management Zone Leqend Item Complete Item Incomplete - Needs your action i 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified ffltlD Environmental Review Required: YES DATE OF COMPLETION: _^^_ NO TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval nn Discretionary Action Required: YES APPROVAL/RESO. NO. PROJECT NO. ' NO DATE: TYPE OTHER RELATED CASES: Compliance with conditions of approval? If no';, state conditions whuh require action. Conditions of Approval - Coastal:YES NO X DATE OF APPROVAL: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval - n D D nan n Landscape Plan Required: YES NO V See attached submittal requirements for landscape plans Site Plan: 1 3 4 Zoning: 1 Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. Provide legal description of property. Provide assessor's parcel number. Setbacks: tfnn 06 n Elu n Front: Int. Side: Street Side: Rear: 2. Lot coverage: 3. Height: 4. Parking: Guest Required Required Required Required Required Required Spaces Required Spaces Required Shown Shown Shown Shown Shown Shown Shown Shown DDD Additional comments £.id i^narks have been made on the building plans. These marked-up plans ray be picked up at the Building Department. These marked- up plans must be resubmitted with the revised plans for this project. Have plans been marked up? YES Additional Comments NO OK TO ISSUE 7/ll/QD PLNCK.FRM 2560 ORION WAY CARLSBAD, CA 92008 Citp of Cariafcafc F/flE DEPARTMENT PAGE1 OF_Z_ (619) 931-2121 PRO.IFP.T AvfiAAAL exu/'/f^v r ARCHITECT j"^£-/-t~V W- T O Ic1 Pw , nWNFR nnruiPANr.Y R 7 CONST. \TVSPRINKLERED -QaENANT IMP. PLAN CHECK REPORT \OviTS ADDRESS 2-270 (?V^i(^0 UM APPROVED DISAPPROVED ELAN CHECK*7b - //.ce 1 - (^jf- KO' j( c '• ';-j / )';/--cJC ADDRESS /CA'L/f/fu 71 . A rV" PHONE "1 ^O~ ?H 'AC/ ADDRESS PHONE V /-/ TOTAI SQ.FT. STORIES APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: 1. 2. 3. 4. 5. 6. 7. "V. PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. Provide specifications for the following: Permits are required for the installation of ah fire protection systems (sprinklers, stand pipes, dry chemical, halon, COa, alarms, hydrants). Plan must be approved by the fire department prior to installation. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT PcK Ai r H^ / 3 The following fire protection systems are requir ^(Automatic fire sprinklers (Design Criteria: 2 Dry Chemical, Halon, CO2 (Location: D Stand Pipes (Type:.) D Fire Alarm (Type/Location: Fire Extinguisher Requirements: . 'H One 2A rated ABC extinguisher for each fco , extinguisher not to exceed 75 feet of travel. D An extinguisher with a minimum rating of sq. ft. or portion thereof with a travel distance to the nearest to be located: _ Other: 8. Additional fire hydrant(s) shall be provided EXITS . 9. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. .10. A sign stating, " This door to remain unlocked during business hours" shall be placed above the main exit and doors .11. EXIT signs (6" x 3A" letters) shall be placed over atl required exiits and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL .12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. .13. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. ,14. Additional Requirements. .15. Comply with regulations on attached sheet(s). Plan Examiner.Date- Report mailed to architect Met with .Attach to Plans