Loading...
HomeMy WebLinkAbout2271 COSMOS CT; ; CB901929; PermitBUILDING PERMIT 01/29/91 13 54 Page 1 of 1 Job Address- Permit Type Parcel No Valuation 2271 COSMOS CT INDUSTRIAL TENANT IMPROVEMENT 213-050-41-00 18,631 Str Permit No Project No Development No Fl Ste 03901929 A9002219 %05 01/2"/9l 0001 Oi 02 Construction Type IIIN Occupancy Group B2 Class Code Description SHAFT PROCESSING & GRIPPING ROOM INSIDE BLDG 640 SF Appl/Ownr OWNER CONTRACTOR WARE & MALCOM ARCH (ROBYNN L 6125 CORNERSTONE CT SAN DIEGO, CA 92121 ANDREX DEV CO ) 619- £57 Status Applied Apr/Issue Validated By 546-1121 see.-oc ISSUED 12/12/90 01/29/91 CD * * * PACIFIC INTERIORS 6364 FERRIS SQUARE SAN DIEGO, CA 92121 Fees Required *** A** Lie OWNER Lie C 502376 619-552-0600 Fees Collected & Credits Fees 1,017 00; Adjust m e n t. s 0 0' Total Fees 1,017 00 Fee description BuildniQ Permit , Plan Check Strong Morion Fee Enter 'Y' to Autocalc License Tax > * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Enter "Y" for Electric Issue Fee > Enter "Y" for Remodel :; > * ELECTRICAL TOTAL ($10 Mini mum) Enter 'Y' for Mechanical Issue Fee> Each Install/Reloc Appliance Vent > * MECHANICAL TOTAL Total Cz edits- Totcil Payments 129 Balance Due- 888 Units Fee/Unit Ext fc 198 129 3 652 982 5 10 15 15 1 00 4 50 4 20 00 00 00 ?e 00 00 00 00 00 00 00 00 00 50 00 Data Y N Y Y V INSP-1 CLEARAK NAl CFJ APPROVAL DATF 4W« CITY OF CARLSBAD 2075 Las Palmas Dr, Carlsbad CA 92009 (619) 438-1161 / PERMIT APPLICATION I, City of Carlsbad Building Department / 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) «8-ii6i L PERMIT TYPE_ I A [^COMMERCIAL QigEW j^fTENANT IMPROVEMENT B D INDUSTRIAL DNEW QTENANT IMPROVEMENT C PRESIDENTIAL DAPARTMENT Q] CONDO [^SINGLE FAMILY DWELLING fj ADDITION/ALTERAT ION DDUPLEX QDEMOLITION ORELOCATION [^MOBILE HOME OELECTRICAL QPLUMBING QMECHANICAL npooL DSPA nRETAIN'NG w*i-L DSOLAR D°JJIER_ PROJECT INFORMATION PLAN CHECK No Bui IcTTng or Suite No 9818 12/32/90 0001 03 02 - FOR OFFICE USE ONLY ,00 Address ^3 -, j Nearest Cros -x=€Fir-Vl Phase NoLEGAL DESCRIPTION Lot No ..- Subdivision Name/Number ^~ Unit No CHECK BELOW IF SUBMITTED Q2 Energy Calcs Q2 Structural Calcs Sol is Report Addressed Envel ASSESSOR'S PARCEL DESCRlPTIoM OF UOR EXISTING USE BLDG SO FTG iA OF STORIES CONTACT PERSON NAME CITY (eSIGNATURE ADDRESS ZIP CODE TELEPHONE 4 APPLICANT NAME nCONTRACTOR AGENT FOR CONTRACTOR ADDRESS ZIP CODE O AGENT FOR OWNER DAY TELEPHONE PROPERTY OWNER QLESSEE ADDRESS ZIP CODE DAY TELEPHONE 6 CONTRACTORNAME ->/,c CITY SIGNATURE J STATE STATE LIC #, ADDRESS ZIP CODE LICENSE CLASS ^U DAY TELEPHONE CITY BUSINESS LIC # DATE DESIGNER NAME CITY ADDRESS STATE/Ot ZIP CODE ti/JS L-DAY TELEPHONE STATE LIC # 7 WORKERS' COMPEbRATION Workers' Compcnsat'nfri Declaration I hereby affirm that I have a certificate of consent to self insure issued by trie Director of Industrial Relations or a certificate of Workers Compensation Insurance by an admitted insurer or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800 Lab C) INSURANCE COMPANY EXPIRATION DATE Certificate of Exemption 1 certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION Owner Builder Declaration 1 hereby affirm that I am exempt from the Contractor s License Low for the following reason | | I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not ocply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the buitding or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale ) || i as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) II I am exempt under Section Business and Professions Code for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9 commencing with section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 ?5533 or 25534 of the Presley Tanner Hazardous Substance Account Act? DYES QNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management distncf DYES Quo Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' DYES QNO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY HAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS NET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT i CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS 10 APPLICANT'S SIGNATUREI certify that I have read the application and state that the above information is correct I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOUENCE OF THE GRANTING OF THIS PERMIT Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code) APPLICANT S_SJGNATURENTS_^ fno CONTRACTOR PHONE APPROVED BY DATE ~T WHITE File YELLOW Applicant PINK Finance RECEIVED 0 1 FINAL BUILDING INSPECTION DEPT BUILDING ENGINEERING FIRE PLANNING U/M WATER PLAN CHECK#- CB901929 DATE 03/01/91 PERMIT# CB901929 PERMIT TYPE ITI PROJECT NAME SHAFT PROCESSING & GRIPPING ROOM INSIDE BLDG 640 SF ADDRESS: 2271 COSMOS CT CONTACT PERSON/PHONE#• MH/KAY/552-0600 SEWER DIST CA WATER DIST. CA INSPECTED i /, DATE I / BY Cj, 1(0 AJLuL-*- INSPECTED \I[D / <7>- APPROVED X DISAPPROVED INSPECTED DATE BY INSPECTED APPROVED DISAPPROVED INSPECTED DATE BY INSPECTED APPROVED DISAPPROVED COMMENTS '" CITY OF CARLSBAD INSPECTION REQUEST PERMITtf CB901929 FOR 04/18/91 DESCRIPTION: SHAFT PROCESSING & GRIPPING ROOM INSIDE BLDG 640 SF TYPE: ITI JOB ADDRESS: 2271 COSMOS CT APPLICANT: WARE & MALCOM ARCH (ROBYNN L.) PHONE: PACIFIC INTERIORS PHONE: ANDREX DEV. CO. PHONE: CONTRACTOR: OWNER: INSPECTOR AREA TP PLANCK# CB901929 OCC GRP CONSTR. TYPE VN STR: FL: STE: 619-546-1121 619-552r-( REMARKS: MH/KAY/552-0600 SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: —RELATED PERMITS—PERMIT# TYPE CB880631 ELEC CO910033 COFO STATUS EXPIRED ISSUED CD 19 29 39 49 LVL DESCRIPTION ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ACT COMMENTS ***** INSPECTION HISTORY ***** DATE DESCRIPTION 041091 Final Combo 040391 Final Combo 032291 Final Combo 031291 Final Combo 030891 Final Combo 030691 Final Combo 030491 Final Combo 021391 Interior Lath/Drywall 020591 Frame/Steel/Bolting/Welding 013191 Frame/Steel/Bolting/Welding ACT CO CO NS CO CO CA CO AP AP CO INSP TP TP TP TP TP TP TP TP TP TP COMMENTS IMPRPR FLSH @ RF JACK FLSHING/ROOFNG ARND REAR JACK CORR NOT COMPLETED MECH. ON ROOF RED IRON/FLOATING STUDS ESGIL CORPORATION 932O CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 560-1468 DATE' JURISDICTION- PLAN CHECK NO'SET .IT I CANT PROJECT ADDRESS; 42.11 (24- jPLAN CHECKER JFILE COPY QUPS ["^DESIGNER PROJECT Tl Q O?rvit lac.. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified on \\^&. rem&t-^s, _ are resolved and D D checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: * QlftUflOO ^mP'7 ^^ } cr* ^ 7 Esgil staff did not advisexQie applicant contact person that plan check has been completed. II Esgil staff did advise applicant that the plan check has — been completed. Person cont< *-~J-rcted: Date contacted: REMARKS;"Th Telephone #_ :^^r^v JJa^g Enclosures: ESGICCORPORATION DGA D^A DRN QDM ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 56O-1468 DATE. ML/1 ft/<?Q JURISDICTION- _ PLAN CHECK NO: PROJECT ADDRESS PROJECT NAME: CARLSBAD SET C4- ft , TA^LOE V/Un£ £I<->I.T= <^oMT=>/iviV. < u JPLAN CHECKER JFILE COPY QUPS QDESIGNER D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: War<z ^MfilcoiviV-) Avc\-i. h§ n^ 30O Esgil staff did not advise the applicant contact person that plan check has been completed. I I Esgil staff did advise applicant that the plan check has — been completed Person contacted- _ Date contacted: REMARKS- Telephone #_ EnclosuresESGIIQ30RPORATION DGA HAA BIN QDM PLAN CORRECTION SHEET PLAN CHECK NO.; Q O - I TENANT IMPROVEMENT Date plans received by jurisdiction JURISDICTION; CARLSBAD € \Aa \r.orv\l-) Xvr.W. X-Ur? .:TO. FCr> bumr~* Gk 6 l/16Lorngr<.'c-Toner 300. Ao~-~.#, PROJECT DATA OCCUPANCY: BUILDING USE:Mane?d)r\ no o rn (JJo\e n TYPE OF CONSTRUCTION ACTUAL AREA; -^6 so r T ALLOWABLE AREA: >g>C? O O O SQ STORIES; Qng ^-A &S»O nn g^O )x HEIGHT: ** SPRINKLERS: OCCUPANT LOAD: REMARKS: Date plans received by Esgil Corporation Date initial plan check completed _By &„_ &.»o Applicant contact person Tel FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation. n"L5/^ ^^""flt.l"?^^ access^for the The circled items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. LIST NO 56 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC / 0 / ^ ^1 ) Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468 Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to The jurisdiction's building department Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans Section 302(d) Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code Plans and calculations shall be signed by the California state licensed engineer or architect v,here there are structural changes to existing buildings or structural additions Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code Provide the correct address and suite number of tenant space on the plans Section 302(d) Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled Section 302 When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy Please provide complete details to show the building with comply Section 502 UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing sjstems and any other permanent equipment Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building 14 15 On the first sheet of the plans indicate. Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible The building official may require a technical report to identify and. develop methods of protection from hazardous materials Section 901(f) If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation Section 404 The number of control areas within a building used for retail/wholesale stores shall not exceed two, the number of control areas in buildings with other uses shall not exceed four Footnote 1, Tables 9-A and 9-B The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage" Footnotes 2 and 3, Tables 9-A and 9-B Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1987 NEC Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered Draw the plans to scale and indicate the scale on the plan Section 302(d) Indicate the use of all spaces adjacent to the area being remodeled or unproved Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors Identify and provide construction details for proposed new fire rated walls Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls 12/29/89 Identify existing walls to be removed, existing walls to remain and proposed new walls Identify bearing walls, non-bearing walls, and shear walls Provide a section view of all new interior partitions Show Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" Method of attaching top and bottom plates to structure (NOTE Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load) Wall sheathing material and details of attachment (size and spacing of fasteners) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five Similar surfacing shall walls from the floor to around urinals and within water closet compartments Section 510(b) inches up the wall be provided on the a height of 4 feet Note on the plans "All interior finishes must comply with Chapter 42 of the UBC" Specify "Class flame spread rating (minimum) for " Lateral bracing for suspended ceiling must be provided (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No 12 gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling A strut (adequate to resist the vertical component from lateral loads) fastened to the main runner shall be extended to and fastened to the structural members of the roof or floor above These horizontal restraint points shall be placed 12 feet o c in both directions with the first point within 6 feet of each wall Attachment of restraint wires to the structure above shall be adequate for the load imposed UBC Standard 47-18 31 In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s f and no horizontal dimension exceeds 60 L F (if space has sprinklers, then 3,000 s f and 100 L F ) Section 2516(f) In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s f and no horizontal dimension exceeds 60 L F (if space has sprinklers, then 9,000 s Section 2516(f) f and 100 L F ) Storage areas exceeding 1000 sq ft in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooas and assembly uses exceeds 5000 squire feet Section 3802(c) The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled See the attached correction sheet Title 24, Part 2 The \»idth of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors Section 2-3304, Title 24 Specify lever-type hardware for passage doors on floors accessible to the disabled Section 2-3304, Title 24 If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan Section 705 In areas where the occupant load exceeds two exits are required See Table 33-A 2/15/90 36 / X / / (42J / Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served Section 3303(c) The maximum number of required exits and their required separation must be maintained until egress is provided from the structure Section 3303(a) Rooms with more than 10 occupants may have one exit through one adjoining room Revise exits to comply Section 3303(e) Exit signs are required for exits serving an occupant load exceeding 49 Show all required exit sign locations Section 3314(a) Show that exits are lighted with at least one foot candle at floor level Section 3313(a) Show the ' locations of existing exits from the building and show the path of travel from the remodel area to the existing exits Note on the plans "All exits are to be openable from inside without the use of a key or special knowledge" In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" This signage is only allowed at the main exit Section 3304(c) Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minunum door swing of 90 degrees Maximum leaf width is 4 feet Section 3304(f) ^ . Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area Section 3303(b) Applies to door(s) Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access) Section 3304(i) Doors should not project more than 7 inches into the required corridor width v.hen fully opened, nor more than one-half of the required corridor width when in any position Section 3305(d). Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area Section 3304(h) Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock unless it is panic hardware Section 3318 Double acting doors are not allowed when serving a tributary occupant load of more than 100, or v,hen part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware Section 3304(b) Corridors must provide continuous protection to the exterior of the building Interruptions by an intervening room is not permitted Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms Section 3305 Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection Corridors serving less than 10 occupants must be a minimum of 36 inches in width Section 3305(b) When two exits are required, dead end corridors and exit balconies are limited to 20 feet Section 3305(e) Corridors serwng 30 or more occupants shall ha\e vails and ceilings of one-hour construction except a Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor Exterior sides of balconies exterior exit c Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing Section 3305 (g) Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100 Section 3305(g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc ) ffb lx$ OK v<2 Vv 2/14/90 / Section 3305(g), Exception 5 is applicable only for corridors on one floor, the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels If non-rated corridors are used per Section 3305(g), Exc 5, provide a reference to the corridors on the floor plan, noting 1 Corridors are non-rated per Section 3305(g), Exception 5 2 Smoke detection system must be listed by the State Fire Marshall and be a supervised low voltage system 3 Smoke detectors shall be maximum 30' on center 4 Power supply shall be dedicated branch circuit Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall Clearly show where the non-rated corridor system terminates and a rated corridor system commences One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b) Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 3305(h) Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor Such openings shall be protected by fixed, approved 1/4 inch thick wired glass installed in steel frames Section 3305(h) Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations Section 3305(g) Show the location of fire dampers Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor vails and ceilings Section A306(j) If a room with an exhaust fan has a door opening into a rated corridor, show how make- up air will be provided to the room The door cannot be undercut, nor can a louver in the door be provided Section 3305(h)l If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision If a second door is provided entry, note that it v>ill be from the car side without special knowledge or effort at the elevator readily openable a key, tool or Section 5106 Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment) When nonflammable supply cylinders for medical gas systems are located inside buildings, they shall be in a separate room or enclosure separated from the rest of the building by not less than one-hour fire-resistive construction Doors to the room or enclosure shall be self-closing smoke- and draft-control assemblies having a fire-protection rating of not less than one hour Rooms shall have at least one exterior vail in which there are not less than two vents of not less than 36 square inches in area One vent shall be within 6 inches of the floor and one shall be within 6 inches of the ceiling When an exterior wall cannot be provided for the room, automatic sprinklers shall be installed within the room and the room shall be vented to the exterior through ducting contained within a one-hour- rated shaft enclosure Approved mechanical ventilation shall provide six air changes per hour for the room Section 702(b)4 6/13/90 71 72 73 74 75 76 77 78 79 80 81 Se-cr Submit plan showing location of all panels Submit panels schedules Submit electrical uoad calculations Indicate existing main service size Indicate existing/total main service load Indicate new additional loads Indicate wiring method, i e EMI, metal flex Show exit signs plan(s) As pe 1988 UBC, provic signs and exit ill on the electrical lighting Section 3313 and 3314 of the two sources of power to exit nination Provide receptacleOs) within 25" of the roof mounted A/C units/ UMC Section 509 Provide multiple Title 24, 2-5319 switch lighting controls per Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54 MECHANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant Section 605 and 705, UBC Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment Provide drain, waste and vent plans Provide water line sizing calculations UPC Section 1009 Detail how floor drain trap seal is to be maintained UPC Section 707 (floor drain trap priming) Show P & T valve on water heater and detail drain line route from P & T valve to the exterior UPC Section 1007(e) Show 1/4" per 12" slope on drain and waste lines UPC Section 407 Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments) UBC Section 605 ENERGY 94 ) Provide complete energy design calculations, including all existing design and new energy design for this building See attached non- residential energy design checklist For remodels in an existing conditioned space, show that the remodeled space will not use more energy than tre existing space or show the remodeled space will conform to latest energy design standarcs CITY OF CARLSBAD SUPPLEMENT Detail access equipment and working clearances to HVAC Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged Section 1205, UMC One-hour corridors shall not be used as an integral part of a duct system This includes the space above a dropped ceiling within the one-hour corridor UMC Section 706(b) PLOMBIH6 Provide gas line plans and calculations, showing pipe lengths and gas demands UPC Section 1219 ido 101 102 103 Floor drains Policy) must have auto-prime (City A grease interceptor is required Show details complying with City Policy 83-34 Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6) Condensate drains must connect to a wet trap (dry traps are not permitted) (Memo 1/14/83) Show fans are duct type, City permit ductless fans Policy does not Romex is not permitted in industrial or commercial buildings (City Policy) No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official (City Policy) All panel boards shall have a minimum 100 amp rating or approved by the Building Official 4/6/90 104 The minimum 100 amperes rating of a service disconnect is 105 The minimum size conductor to receptacles and lighting fixtures in commercial and industrial buildings shall be #12 Cu 106 AC(BX) cable is not allowed in group A, B, E, H and I occupancies (see Ord for exception) MISCELLANEOUS Please see that follow additional corrections or remarks 1081 To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 109^ Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list' Please check Yes No NOTE: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall They are provided here as a courtesy to assist designers in developing the project documents All applicable provisions may not necessarily be included Please direct any questions regarding interpretations of these provisions to the local Fire Department s/Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction Section 3305(g)l Where exit signs are required by Section 3314(a), approved and listed internally, externally or self-illuminated low-level exit signs complying with Section 3314 shall be required The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door Such signs shall be of a type which is perceptible to the sense of touch Section 3314(e) S/6 '/ '/ Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level Such marking shall be of a type which is perceptible to the sense of touch Section 3314(f) Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38 Section 505(e)6 EXCEPTION. Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection In educational occupancies, storage and janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating Section 802(c) Section 1807 should be reviewed for all high- rise buildings The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300 If emergency warning systems are required, they shall activate a means of warning the hearing impaired Flashing visual warnings shall have a frequency of not more than 60 flashes per minute The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468, to perform the plan check for your project If you have any questions regarding these plan check items, please contact at Esgil Thank you Enclosures ration -S-^f V o^on Uk &^_o £va,W V>ri // i<T) n to oioin > u? ( T t On. rocr IP V <ZT I 0\ i *£i u a iic? ) u * 2/28/90 FLAN CORRECTION SHEET •flTRTSDICTIOMi CA&\^ g,A D PLAH CHECK NUHBER:_HL DATE: Dg^MRL^ \& . D GLEN ADAMEK FLAN CHECKER: H GAJQr D 1 f^A-r^ri AMQ PE.TAIL fr.t-U=-i£ To \gy\-r TO VVJ/WL.SoS U) ArviD 53 uMTrf WOT" 10., -TO vorrvt ReOLi\egQ PER Foe. ifJ OOC.T 0>mPLH uJiTH DEC 42-1 fcft. LJ6TEO Of MU ^C_ AMO Stt>reA\f> f useo -Ta AIR £teL J/^T_ fee 6g£T>p>J i QO 2. fe.^ .foft. \,o tJFwN fe-K SflLO^ee Poor AT H-4 WIT i,AT M i)Mi-ns c _££. looo CFM PLAN CORRECTION PLAN CHECK NUMBER:— \°(2-<p\ DAIE:___J1E{LE1 LJ GLEN ADAHEK FLAN CHECKER: H GARY ANGEL D J^>MPUET£.D f^QBMfr OR - l=YiVJlfYnEMT. 4 jLf-\A S>to>Aj>Nie» THAT g WITH AT 1 KJOTgi OK) jBfiu Ofi.. . •See. vL ^^»>OM -me. Poft THE. tP_ ^A^ifc 16 rogr To H'fc A CP->/\ AT ffcftT 7. oP OP dorfl-MgT l\J6fcjp ^(o ^Lo^fLH vJiTU TiTLfc "2-4, sf JuL ^T_ i£> us JURISDICTION^ ELECTRICAL FLAN CORRECTION SHEET > DATE: PLAN CHECK NOMBER:_ ^^^ML.J Submit complobo electrical plans and ^—' specifications- QVOLLTK WAGGONER PLAN CHECKER: (H'RAY. NEAL rnDARRELL HORRISON To speed up the recheck process,note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans 131 Provide overcurrent protection on the secondary side of transformers NEC 240- 21/384-16(d) >C Submit plan showing location of all services y. Submit complete one-line diagram of service and feeders IS. Indicate the grounding system to be installed for building service ^ Indicate ampere interrupting capacities (AIC) of service and subservice equipment NEC 230-65/110-9 £4 Indicate sizes of fuses and/or circuit breakers 14.) Submit plan showing location of all A/<r<_J — panels, if- /a/\j</ yzf. Submit panel schedules JJlf. Specify conduit and wire sizes. Specify aluminum or copper conductors and type of insulation 1. Show approximate length of feeders ^ Specify electrode conductor size and type wire (aluminum or copper) Indicate fuse symbols to show fault currents are limited to 10,000 amps on branch circuits, i e JJN, LCL If fuses are not used to limit fault currents on branch circuits to 10,000 amps, specify method to be used Submit plan showing location of all switchboards Submit electrical load calculations . Indicate existing main service size. . Indicate existing main service load 2^1 Indicate new additional loads 24} Indicate wiring method, i e EMI, metal flex yir. Indicate dimension of switchboards and control panels rated 1200 amperes or more NEC 110-16(c) IK Submit plan showing location of all transformers T Indicate the grounding system to be installed for transformers NEC 250- 26(c) . Show exit signs on the electrical lighting plan(s) As per Sec 3313 and 3314 of the 1988 UBC, provide two sources of power to exit signs and exit illumination . Provide receptacle(s) within 25' of the HYAC A/C units UMC Section 509 . Provide multiple switch lighting controls per CAC, Title 24, 2-5319 Any questions on electrical please contact the plan checker shown above, at Esgil Corporation at (619) 560-1468 Thank you. 7/jcrg.G *?^-u Be \/ Ol/OJ/90 ELECTRICAL CORRECTIONS u a •oc *U)oo <"• C H « Cl u a u O 14u u •C -3 U 3JQ O CCl 13*» >O -IE 3cro « .0 I)*• >o oC -4 C -4•5 au« siJ -«cg 2o H « jc« e tiv vu £ xw o x £> c0 - , - -i ^ Cl X •J — u > J3O 3 O -4•4 w C « -3M « J OX 14 -4 14 .£ U " Cl -4 C. JZ O. vi 3 C, ^ § ' S" VI tl U C 14C OCn C -4 M Cl C O U -4 o -a ti u c JS -^ l» H O o H -H u B W " U <5B C, -• 1 O Cl O «"l -4"3 c «5 u ii 3 Cl C *»^ tl Cl <•3 o e ~ uCl vi Cl «5a > a - > - "5e -oU v,C 1a a-4. — eo. -. E JQ 8 S- Su «•H Ovi Utl Ca 3 Access cannot bo walegal barriers that> 3-i cr §- "O -3 ss n O BU Vc ua u-4 <9i-l 8-58 5 • TJ« C ne a — 1 , % „• t>. « c — « C Cl V!O > L> 3 M Q. O O •o 3 a 0 a. u -o o1 ei c - c u« -3 V O* C 3 Cl O O O inn o\ o ~* a o >o o 3 o nOne uc« O Cn uC Cl uno « C* vi in0 t> JVI Ujj a Dc o 1 ««i n cc U **vi a e:ouou a oc a 2u < ti,i v -39 u u o n 1-HJJ 0 «5 -0 — -o3 c. c 0•-• n " ? g. Ou e - Ia uvi U3 O O -O2 5 . C5 §5 §<J O•» viu atl E S1 I-4 a•a ti TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction Plan Check No References to section numbers with prefix "2" are to Title 24, California Code of Regulations, Part 2 (California Building Code) Prefix "3" is for Part 3 (California Electrical Code) Prefix "5" is for Part 5 (California Plumbing Code) Exemptions claimed for any item shall be requested in writing and shall include all data needed todetermine "unreasonable hardship" as described in Section 2-422 SITE DEVELOPMENT / HANDICAPPED PARKING SPACES Provide _handicapped spaces 2-7102(b) Space shall be so located that handicapped persons are not compelled to wheel or walk behind parked cars other than his/her own 2-7102(c) Parking space shall be a minimum of 9 ft x!8 ft with adjacent marked 5 ft loading zone Double space shall be 23 ft wide Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle 2-7102(c) Maximum slope of parking surface in any direction shall not exceed 1/4" per foot 2-7102(e) Parking space(s) shall be identified vith the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the parking stall) 2-7102(f) Entrance to parking area (or at each stall) shall have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away 2-7102(f) Entrance to and vertical clearance within accessible level of parking structure shall be 8 ft 2 in to any structural member, duct or pipe 2-7102(g) CURB RAMPS Curb ramps shall be located wherever pedestrian path crosses curb (2- 7103(a)) Curb ramp shall be 48" mm width (2- 7103(b)) with maximum slope of 1 in 12 2-7103(d) A level 48" mm depth landing is required at top of curb ramps over entire curb ramp width. 2-7103(d) If no landing is provided, the slope of flared sides shall not exceed 1 in 12 2-7103(d) Surface is to be slip contrasting finish sidewalk 2-7103(f) resistant and a from adjacent Border markings shall be 12" wide of l/4"xl/4" grooves, 3/4" apart, located at top and sides 2-7103(h) WALKS Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and v.here necessary to provide access snail incorporate pedestrian ramps, curb ranps, etc 2-7101(a) Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec 2-3307 2-3325(c) Walk width shall be 48" minimum, and shall have slip-resistant surfaces 2-3325(a) The maximum cross slope shall not exceed 1/4" per foot 2-3325(a)3 Gratings possible are not 2-3325(b) allowed whenever At each gate or door a 60"x60" level area is required when the gate swings toward the walk 2-3325(e) A 48"x44" deep level area is required when the gate swings away from the walk 2-3325(e) / A 24" clear space is required at strike side of gate or door 2-3325(e) ./ Shout? 4\-ua: •spee.s-PEDESTRIAN RAMPS & YGrv.p a^oc-L^ * a A path of travel with a slope greater than 1 in 20 shall be considered a ramp 2-3307(a) b The maximum slope shall be 1 in 12 2-3307(c 1) The width shall be 48" minimum A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more Group R Occupancies may be 36" when the occupant load is 50 or less 2- 3307(b 1) d The surface of ramps shall be slip- resistant 2-3307(g) e A 60" intermediate landing is required at maximum elevation change of 30" and 72" landing at each change of direction (over 30 degrees) 2-3307 (d 1) f Landings are required at top and bottom of ramps 2-3307 (d 1) g Bottom landing shall be minimum of 72" in the direction of travel Fig 2-33- 11A Headroom of maintained for etc 2-522(f) 80"minimum shall be walks, corridors, aisles, Top landing 2-3307 (d 1) shall be 60" x 60" minimum i When door swings onto top landing, minimum depth of landing required is door width plus 42" 2-3307(d 1 ) j Top landing shall have 60" mm width when door swings onto the landing, with 24" on strike side of door at exterior ramp, or 18" at interior ramp 2-3307(d 1) k Ramp handrails are required on each side of ramp, when slope exceeds 1 in 15 2- 3307(e 1) 1 Ramp handrails shall be continuous, located 30"-34" in height above ramp surface, with 12" extensions beyond top and bottom, and the ends returned 2-3307(e 1) m Handrails shall be 1-1/4" to 2" cross section, spaced minimum of 1-1/2" from wall 2-3307(e 1) n A 2" high curb or wheel guide rail centered 3" + 1" above ramp surface is required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length. 2-3307(h 1) SPECIAL ACCESS LIFTS Lifts may be provided between levels, in lieu of elevator, vhen the vertical distance between landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health 2-5107(a) The lift platform shall be of sufficient size to accommodate a wheelchair (30"x48") 2-5107(a) There shall be a level and clear floor area or landing (60"x60") at each level for access to the lift 2-5107(a) HAZARDS Provide 80" headroom from walkway surface to any overhanging obstruction 2-3326(b) Protruding objects with leading edges between 27" and 80" above finished floor shall not protrude more than 4" into walks, corridors, etc 2-522(f) Free standing objects mounted on posts between 27" and 80" above the floor may project a maximum of 12" 2-522(f) Abrupt changes in level exceeding 4" adjacent to walks, except between walks and adjacent streets or drives, shall be identified by 6" high warning curbs above walk surface 2-3326(a) ENTRANCES AND CIRCULATION ENTRANCES, DOORS, VESTIBULES AND CORRIDORS All primary entrances to buildings shall be accessible to the handicapped 2-3301(f) ft All requirecl passage doors shall have 32" clear opening at 90 degrees (36" door) 2-3304(f) At least one of a pair of doors shall meet the minimum 32" clear entrance width requirement 2-3304(f) ©Threshold shall be no higher than 1/2" above the floor Edge to be beveled with a slope no greater than 1 in 2, if more than 1/4" 3304(i 1) e ^Exterior level landing may slope up to ^—'1/4" per foot in any direction for surface drainage 2-413 ooor hardware shall be of the lever or type, mounted 30" to 44" above the floor and be operable with a maximum effort of 8 5 Ibs for exterior doors and 5 Ibs for interior doors 2-3304(c), 2- 3304(i 2) ©The lower 10" of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors 2-3304(i 3) Building entrance(s) shall be identified by sign with the International Symbol of Accessibility Show location on plan The symbol shall be a white figure on blue background 2-522(b) At turnstile, provide an access gate, 32" clear width opening, within 30 feet of turnstile 2-3304(i 4) There shall be a clear area on each side of door, 60" deep in direction of door swing and 44" deep in opposite direction of door swing. 2-3304(1 1) X Width of clear area on the swing side of the door shall extend 24" past strike jamb for exterior doors and 18" past strike jamb for interior doors X The space between two consecutive doors (vestibule) shall provide a minimum of 48" clear depth between the open door and a. second closed door Doors in a series at a vestibule shall swing in the same direction, or away from the space between them 2-3304(i 1) For corridors over 200 feet long, see special requirements of Sec 2-3305(b)2 FLOORS f Floors of a given story shall be a common level throughout or shall be connected by pedestrian ramps, passenger elevators, or s pecial access lifts 2-522(e) STAIRWAYS NOTE: Only applies where disabled access is provided or required to other levels. Treads shall have smooth, rounded evposed edges and be slip resistart 2- 3306(s) Nosing shall not project more than 1-1/2 inches past face of the riser below 2-3306(s) Risers shall be sufficiently solid 2-3306(s) The upper approach and lower tread of each flight of stairs shall be marked with a contrasting colored strip 2" in width 2-3306(r) On exterior stairs, each tread shall be marked as noted above 2-3306(r) Handrails are required on each side of stairway 2-3306 Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread width beyond bottom nosing and returned to v.all/newel post 2-3306(j 1) Handrails shall be 1-1/4" to 2" in gripping cross section and 1-1/2" clear of wall 2-3306(j 1) Approved stairway identification signs shall be located at each floor level in all enclosed stairways in buildings two or more stories in height The sign shall identify the stairway, indicate whether there is roof access, the floor level, and the upper and lower terminus of the stairway The information shall be presented using raised Arabic numerals and raised braille symbols which conform to Section 522(b)3 The sign shall be located approximately 5 feet above the floor landing immediately adjacent to the door on the strike side Signs shall comply with requirements of U B C Standard No 33-2 ELEVATORS Provide clear inside elevator car dimensions as required by U B C Section 5103(d) 6 and Title 24 2-5103(d 1) X At least one elevator in buildings 4 or more stories in height 80" by 54", with a 42-inch -side slide door Applies only to high-rise buildings, A/E/I occupancies, State-owned buildings, residential care hones, hotels, motels, apartments and condominiums Elevator in buildings more than two stories or buildings where disabled access is required to upper level(s) 68" by 54", v,ith a minimum clear door width of 36" Elevators other than in (b) above serving less than 50 occupants shall have a minimum inside platform of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches Raised Braille markings and Arabic numerals are required on control buttons and door jambs 2-5103(d 1) SANITARY FACTLUIES TOILET FACILITIES ACCESS When located on accessible floors, sanitary facilities shall be made accessible to physically handicapped (2-511 l(a)) Doorways shall have 32" opening width 2-511 1 mininua clear There shall be a level area vith 60" clear depth in the direction of the door swing, and a level area with 44" clear depth in opposite direction of door swing 2-511 l(a) MULTIPLE ACCOMMODATION TOILET FACILITIES Provide clear area 60" diameter x 27" high - or clear space 56" x 63" x 27" high 2-511 l(a) / / / X Doors (other than handicap compartment) are not to encroach more than 12" into above mentioned clear space 2-511 l(a) Provide a 28" clear space between water closet and fixture or 32" clear space between water closet and wall 2-511 l(a) A 48" long clear space is required in front of water closet A 60" clear space is required when the toilet compartment has a side door 2-511 l(a) Water closet compartment door to provide 32" clear width for end entry and 3V clear width for side entry Door to be self-closing 2-511 l(a) URINALS / SINGLE ACCOMMODATION TOILEl FACILITIES Water closet shall be located 28" from a fixture or 32" from a wall 2-511 l(a) Minimum clear space in front of water closet shall be 48" 2-511 l(a) In an existing building, a single accommodation toilet facility may have a space 36" wide x 48 " long in front of water closet 2-511 l(a) GRAB BARS AT WATER CLOSET One at side 42" long extending 24" in front of water closet, one at rear 36" long centered on water closet, both mounted 33" above floor Where a tank- type toilet is used, grab bar may be as high as 36" 2-511 l(a) Bars shall be 1-1/4" to 1-1/2" in diameter with 1-1/2" clearance to v,all 2-511 l(a) Bar fasteners and mounting support shall be able to withstand 250 Ibs /ft in bending, shear and tension 2-511 l(a) WATER CLOSET Height of water closet seat shall be 17" to 19" above floor 5-1502 Controls shall be operable with one hand, and shall not require tight grasping, pinching or twisting of the wrist 5-1502 Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor 5-1502 The force required to activate controls shall be no greater than 5 pounds force 5-1502 Where urinals are provided, the rim of at least one shall project 14" from the wall and be located 17" maximum above floor 5-1503(a) The force required to activate the flush valve shall be 5 Ibs maximum and located 44" maximum above floor 5-1503(b) Provide 30" x 48" clear floor space for forward approach 2-511 l(b) LAVATORIES Provide 30" x 48" clear floor space for forward approach Said clear floor space may include knee and toe space under lavatory described below 2-511 l(b) Provide clear space beneath lavatories 29" high by 30" wide by 8" deep at top and 9" high by 30" wide by 17" deep at bottom from front of lavatory (toe space) The maximum counter surface height should be 3V 5-1504(a) Hot v,ater and drain pipes under lavatories shall be insulated 5-1504(b) Faucet controls and operating mechanism (operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 Ibs 5-1504(c) If self-closing valves are used, they shall remain open for at least 10 seconds 5-1504(c) TOILET ROOM ACCESSORIES Mirror bottom edge shall be located 40" maximum above floor. 2-511 l(b) Toilet tissue dispensers shall be mounted within 12" from the front edge of toilet seat 2-511 l(b) Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc ) shall be within 40" of floor 2-511 l(b) SANITARY FACILITIES IDENTIFICATION On doorways leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" diameter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color Unisex facilities shall be identified by the circle with the triangle superimposed within the circle 2-511 l(a) BATHING FACILITIES One such facility shall comply when provided for the public, clients or employees 2-511 l(a) Shower compartment shall be 42" wide, 48" deep, with a 36" wide entrance 2-511 l(a) Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec 2-511a-9, 5-1505 and 5-1506, i e , folding seat, flexible shower hose, etc GENERAL KEQUIKEHENIS DRINKING FOUNTAIN Drinking fountains shall be within alcoves The alcove shall be not less than 32" wide by 18" deep 2-511 l(c) When the enforcing agency determines that it would create an unreasonable hardship to locate the water fountain in an alcove, the vater fountain may project into the path of travel, and the path of travel shall be identifiable to the blind as follows (1 ) The surface of the path of travel at the v«ater fountain shall be textured so that it is clearly identifiable by a blind person using a cane The minimum textured area shall extend from the wall supporting the water fountain to 1 foot beyond the front edge of the water fountain and shall extend 1 foot beyond each side of the water fountain, or (2 ) Wing vails shall be provided on each side of the water fountain The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the path of travel Also, there shall be a minimum of 32 inches clear between the wing walls. Note on the plans that drinking fountain shall conform to requirements of Sec 2-511c and 5-1507. PUBLIC TELEPHONE / t Provide space 30" x 48" for forward or parallel approach to telephone. 2-511 l(d) Note on the plans that public telephone shall conform to requirements of Sec 2-511 l(d) 23J ELECTRICAL REQUIREMENTS 15, 20 and 30 amp receptacle outlets shall be installed not less than 12" above floor 3-210-50(e) 0 PLUMBING REQUIREMENTS Where kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc , the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i e , use lever- operated, push-type, etc ) If self- closing valves are used, they shall remain open for at least 10 seconds 5-1508 GROUP A OCCUPANCY AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance 2-611(b) This structure requires wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices 2-611(b) Each wheelchair space shall be 60" x 30" and level 2-611(b) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location 2-611(b) This structure requires seats for semi-ambulant persons 24" Clear leg space shall be at least 2-611(b) Center of switches shall be located not less than 36" nor more than 48" above the floor 3-380-8(c) Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible 2-611(b) STADIUMS, GRANDSTANDS, BLEACHERS, PAVILIONS, GYMNASIUMS This structure requires wheelchair seatirg spaces In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices 2-611(c) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location 2-611(c) Ticket booths must be accessible from both sides 2-611(c) Participation areas such as ball courts, exercise rooms, tracks, and clubrooms must be accessible 2-611(c) Spectator and participant sanitary and locker facilities must conform to the requirements of Chapter 2-5 2-611(c) DINING, BANQUET AND BAR FACILITIES / Access shall be provided at primary f entrances 2-611(d) /Wheelchair access shall be provided to all areas where each type of functional activity occurs 2-611(d) / This facility requires / wheelchair seating spaces2-611(d) / At least one wheelchair seating space shall be provided for each dining, banquet and bar area 2-611(d) / Access to wheelchair seating spaces shall be provided by 36" minimum clear width main aisles 2-611(d) Cafeteria line aisles shall be a minimum of 36" clear width 2-611(d) Access to food preparation areas shall comply with provisions for entrance doors and doorways contained in Section 2-3304 2-611(d) Restrooms and powder rooms shall conform to the requirements in Section 2-511 2-61I(d) RELIGIOUS FACILITIES ar Sanctuary areas shall be accessible 2- i t f f Provide wheelchair seating spaces in the sanctuary Use Section 2- 611(b) 2-611(e) Provide wheelchair access to raised platforms, choir rooms, choir lofts, performing areas and other similar areas. 2-611(e) Assembly areas along with enclosed and unenclosed platforms and stages shall be made accessible 2-611(e) Sanitary facilities shall conform to the requirements of Chapter 2-5 2-611(e) ASSISIIVE-LISTENING DEVICES Assembly areas with permanently installed public address systems (other than exclusively for paging or background music), shall provide assistive-listening systems for people with hearing impairments 2-611(f) Since the capacity of the assembly area exceeds 99, this facility requires personal receivers to be available on request 2-611(f) If the system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the performing area A sign shall be posted in a prominent place indicating the availability of assistive-listening devices The sign shall include the international symbol of deafness and wording that states "Assistive-listening System Available" GROUP B OCCUPANCY. KEOJOTREMENTS Group B occupancies used for assembly purposes but having an occupant load of lessthan 50 shall conform to all the requirements for Group A occupancies covered in Section 2-611 2-712(d) SALES FACILITIES General sales, display and office areas together with related toilet rooms must be accessible 2-712(b) Sales employee work stations shall be located on accessible levels Employee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible 2-712(b) This facility requires check stands accessible to the physically handicapped, based upon 1 for 8 checkstands or less, 2 for 9 or more 2- 71200 Where quick check stands are provided, at least one shall be accessible 2-712(b) Check stands shall be made accessible by providing a 36" aisle on the customer side of the stand 2-712(b) Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to be open at all times for handicapped/physically disabled customers" 2-712(b) FITTING OR DRESSING ROOMS / Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the physically handicapped 2-712(b) Minimum dimension of room shall be 60" x 60" 2-712(b) Bottom of the mirror shall be located within 20" of the floor 2-712(b) Height of clothing hooks shall not be greater than 48" from the floor 2-712(b) GROOP H OCCUPANCY. REQUIREMENTS XX // Accessible sanitation facilities in all Group H Occupancies shall be provided as specified in Chapter 2-5 2-913(a) Accessible floors and levels shall comply with the requirements specified in Chapter 2-5 2-913(a) Employee work areas shall be accessible by means of a 36-inch minimum aisle width, and a 32-inch minimum clear opening door width 2-913(a) ADDITIONS, ALTERATIONS AND REPAIRS TO EXISTING BUILDINGS. (2-nOA(b)ll) The area of specific addition, alteration and/or repair, shall comply with the provisions of Title 2k Additionally The primary entrance to the building and path of travel to the specific area shall be accessible to the handicapped persons Compliance must be shown, beginning from the existing parking area and leading to the area of alteration Existing restroonis, vater fountains, and public telephones which serve said specific area must be shown to be accessible to and functional for handicapped persons Information regarding handicapped accessibility shall be posted in lobby per Sec 2-522 12/29/89 DOCUMENTATION OF UNREASONABLE HARDSHIP job Address Plan Check No_ Owner__ Date It is requested that the above named project be granted an exception from the requirements of the State of California Title 24 handicapped accessibility provisions, as specifically noted below. 1. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXEMPTED 2. The cost of all construction without excepted items, is. 3. The impact on financial feasibility of the project, if the requested exception is not approved is- • 4. The facility is used by the general public for the purpose of: 5. The exceptions being requested will not penalize handicapped accessibility as equivalent facilities are available as follows. 6. Exceptions requested, and data provided, by. AUUKEtsb TELEPHONE Department Use Only Findings and Decision of the Enforcing Official: Signature of Enforcing Official Date HA-1 010190 REMODEL OR TENANT IMPROVEMENT CONSTRUCTION VALUATION The Building Official is mandated by State law to determine the value of work proposed in each application for a Building Permit The value to be used, shall be the total value of all construction work for which the permit is issued as well as all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevators, fire exting- uishing systems and any otner perranent equipment. Uniform Building Code Section 304 (a) *********************************************************************** APPLICANT PLEASE COMPLETE SITE ADDRESS PLAN CHECK NO DESCRIPTION OF PROPOSED WORK AREA OF (I REMODEI I I TENANT IMPROVEMENT I I ADDITION PROPOSED WORK INCLUDES NSW SUSPENDED CEILING I I YES I I NO NEW hVAC I I YES I 1 NO NEW FIRS SPRINKLERS I I YES f~1 NO NEW PARTITIONS I I YES [ 1 HO NEW PLUMBING I I YES I I NO NEW ELECTRICAL I I YES I I NO HAS A CONTRACTORS ESTIMATE BEEN RECEIVED FOR THE PROPOSED kORK^ [ ]YES [ ]NO ITEMIZED COST ESTIMATE IS ATT^CrED f ] YES [ ] NO I CERTIFY THE VALUE OF ALL PROPOSED CONSTRUCTION WORK COVERED BY THE PERMIT APPLICATION INCLUDING ALL STRUCTURAL WORK, FINISH WORK, PAINT- ING, ROOFING, ELECTRICAL, PLUMBING, HEATING, AIR CONDITIONING, ELEVATORS, FIRS EXTINGUISHING SYSTEMS, AND ALL PERMANENT EQUIPMENT IS.? _ THIS VALUE IS BASED ON: 1 I DESIGNER'S ESTIMATE I I CONTRACTOR'S ESTIMATE I I OTHER, DESCRIBE BASIS _ THE ABOVE INFORMATION IS TRUE AND CORRECT . _ _ I I APPLICANT Q DESIGNER ( I CONTRACTOR********************************************************************** PLAN CHECKER USE ONLY THE VALUE IS ACCEPTABLE CH YES CD NO AN ITEMIZED COST BREAKDOWN IS REQUIRED TO CONFIRM THE ESTIMATED CONSTRUCTION VALUE. I I YES (~| NO BY DATS Page 1 of 2 Remodel Or Tenant Improvement Information Form Plan File No ~ tf Jurisdiction Project Address "3 2/1 ( Oc?a.rvtO€» (L,\. _ Date REMODEL OR TENANT IMPROVEMENT BUILDING CODE INFORMATION REQUIRED PRIOR TO PLAN SU6HITTAL In order to complete a plan review of a remodel or tenant improvement within an existing building it is necessary that the information in Items 1-11 be provided or the approved plans be provided for the existing building »i»»«»»« i »»»»«» i n »««»«-»«««»«» »»»«<n«** «»«»»« mum-n-nn « i ««» m mmim»»iinn»ii«»nnminn<»««««i)i«» »»«»»»»»« «n Circle the existing type of construction for this building I, II-FR , Il-lhr , II-N, Ill-lhr , III-N, IV, V-lhr , V-N T Does this building have fire sprinklers throughout7 Yes y Does the proposed project create a change in use or occupancy classification9 Yes Describe the previous use of the project area 0 No No Describe the proposed use of the project area J Existing Building Area Improvement Area_ ( 5 J How many stories are in this building7 What story is the improvement on7 Does this project involve alterations to Existing fire walls Yes No Existing floor or roof loads Yes No Existing building structure Yes No Existing HVAC equipment Yes No If "MS", see fllO below Existing electrical service loads Ves No Existing lighting tes No If "YES", see #10 below IJhat is the approximate date that construction of the existing building was permitted7 ENERGY CONSERVATION Which of the following were checked and approved for Title 24 Energy Conservation at the time the original building was approved Building envelope Yes No HVAC equipment Yes No Area lighting Yes No Water heating Yes No Will the proposed project significantly alter any element that v.as approved7 Yes, No If "YES", see 010 below HANDICAPPED ACCESS FACILITIES Which of the following has been approved for compliance with the handicapped access standards of Title 24, CAC Parking & access to the building Yes No Building entrance doors Yes No Building stairs & elevators Yes No Existing public restrooms Yes No 10. ENERGY DOCUMENTATION a. Remodels to existing conditoned spaces require that a Form CF-1 (attached) be completed, signed and imprinted on the plans Additionally, if the building envelope, lighting or HVAC equipment are to be altered or added, appropriate State required documentation must be submitted b. Provide copies of all existing CF-1 Forms for this building. c Provide a copy of any existing approved energy design for the building. 12/16/87 Page 2 o\ PLANS y Plans shall clearly show all demolition and new construction proposed DJ Plans shall clearly show exit systems, fire rated construction details, occupancy require- ments, handicapped access provisions and other requirements necessary to show the work will comply with adopted codes and ordinances If structural revisions or increased ]ive or dead loads are proposed the structural plans details and calculations shall be provided and shall be signed by a California licensed engineer or architect If electrical system revisions or increased electrical loads are needed provide electrical plans and specifications showing location of panels, panel schedules, existing service size, existing building load, additional loads, wiring method, exit signs and emergency lighting when required If plumbing revisions or additions are proposed provide plumbing layout, details and specifi- cations. Include sizing calculations when necessary to justify pipe sizes All sheets of the plans are requried to be signed by the responsible designer Information is provided by Title Datet Prepared by« Jurisdiction CARLSBAD VALUATION AND PLAN CHECK FEE p Bldg. Dept, g Esgil PLAN CHECK NO. <? 0 ' BUILDING ADDRESS APPLICANT/CONTACT BUILDING OCCUPANCY TYPE OF CONSTRUCTION I PHONE NO. DESIGNER PHONE CONTRACTOR PHONE t BUILDING PORTION. ~~rr Air Conditionine Commercial Residential Res. or Comm. Fire Snrinklers Total Value BUILDING AREA 6*\0 s-}(\\^J& -r^'HU;// VALUATION MULTIPLIER 30. *2 ^^_(2 ^ § (a e VALUE ^x 4 \^^^b — ^^}c( L*^I V •* &t »T> 1-2-CP.— Building Permit Fee $ Plan Check Fee $ COM ME NTS •/ SHEET I OF | >> PLANNING CHECKLIST Plan Check No, ^0- /f£? Address Zzr/ Planner 1//>J C^t^^L Phone 438-1161 ext (Name) APN 0) <u at4~* *J 4-»to ro to Type of Project and Use //^DMcriis/lL- 7~Z- _ Zone /*M _ Facilities Management Zone 5" X <\j ro -a Legend -C -C -C<-> u u 10 a. a. a. 0LH Item Complete Item Incomplete - Needs your action 1,2,3 Number in circle indicates plancheck number where deficiency was identified D Environmental Review Required YES NO /C TYPE DATE OF COMPLETION * Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval D Discretionary Action Required YES NO /K TYPE APPROVAL/RESO NO DATE PROJECT NO OTHER RELATED CASES Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval EfCD D California Coastal Commission Permit Required YES NO DATE OF APPROVAL San Diego Coast Distnct, 1333 Camino Del Rio South, Suite 125, San Diego, CA 92108-3520 (619) 297-9740 Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval D D Landscape Plan Required YES NO >C See attached submittal requirements for landscape plans Site Plan crfro HD D Zoning 3 4 Provide a fully dimensioned site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks Show on Site Plan Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and dnveway Provide legal descnption of property Provide assessor's parcel number Setbacks Efn n Q"6n QT] D DDD 0*1 Front Int 'Side Street Side Rear ^/" 2 Lot coverage *J/& 3 Height f^/fi'O*' 4 Parlong Additional Comments Required Required Required Required Required Required Spaces Required Guest Spaces Required Shown Shown Shown Shown Shown Shown Shown Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE PLNCK FRM 2560 ORION WAY Cltp Of ° (619) 931 2121 DISAPPROVED PLAN CHECK REPORT APPROVEDX •' PLAN CHECK* PROJECT IP\^LQR MflOt L.7UL-h- ADDRESS ARCHITECT IjQftRZ <* M fll/V)<U & A'A& fi FC€t T^A D D R FSS OWNER AkJ^flC* bgV C'O _ ADDRESS /44-0) 5 OCCUPANCY "" _ CONST -3M _ TOTAL SO FT ^S'^3 (D STORIES K'SPRINKLERED D TENANT IMP (nUQ 03 a ' APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS PLANS; SPECIFICATIONS, AND PERMITS 1 Provide one copy of floor plan(s), site plan, sheets X 2 Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project 3 Provide specifications for the following _A 4 Permits are required for the installation of all fire protection systemst(sp_mTklers) stand pipes, dry chemical, halon, CO2, alarms, hydrants) Plan must be approved by the fire department prior tcTinstallation 5 The business owner shall complete a building information letter and return it to the fire department FIRE PROTECTION SYSTEMS AND EQUIPMENT 6 The following fire protection systems are required QxAutomatic fire sprinklers (Design Criteria /?^) PeR. *J FP& 13 ) ri Dry Chemical, Halon, COz (Location ) D Stand Pipes (Type ! ) D Fire Alarm (Type/Location ) 7 *.Fire^Extinguisher Requirements , [TU^ne 2A rated ABC extinguisher for each faDOU sq ft or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel U An extinguisher with a minimum rating of to be located D Other 8 Additional fire hydrant(s) shall be provided EXITS A 9 Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort 10 A sign stating, " This door to remain unlocked during business hours" shall be placed above the mam exit and doors 11 EXIT signs (6" x 3A" letters) shall be placed over all required exiits and directional signs located as necessary to clearly indicate the location of exit doors GENERAL Y 12 Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code 13 Buildmg(s) not approved for highipiled combustible stock Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids If high stock pil mg is to be done, comply with Uniform Fire Code, Article 81 14 Additional Requirements MmP^I UJ iTi-l #£QuiAfM£iJT£> oF tfftrt£Le~ 7^ O OF T .15 Comply with regulations on attached sheet(s) - L k^u^ ^ /3-30-.n cv. ----- JS=^Report mailed to architect S=^___ Met with _ : _ _ Attach to Plans BUILDING PLANCHECK ENGINEERING CHECKLIST COaa is T C H E K PLANCHECK NO.90~" 1^2,9 L 2 N D C H E K 3 R D C H E K mi COSMOS. A P N PROJECT ID: CT LEGAL REQUIREMENTS Site Plan D ITEM COMPLETE ITEM INCOMPLETE NEEDS YOUR ACTION ITEM SELECTED '—' '—' 1. Provide a fully dimensioned site plan drawn to scale Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimension setbacks. -I I—I 2 Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. I—' '—' 3 Provide legal description and Assessors Parcel Number efc Discretionary Approval Compliance '—' 4 No Discretionary approvals were required. '—' '—' '—' 5. Project complies with all Engineering Conditions of Approval for Project No . '—' '—' '—' 6 Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by Date:. Field Review 1—' 7. Field review completed. No issues raised nn 8. Field review completed. The following issues or discrepancies with the site plan were found DDE1—' A. Site lacks adequate public improvements '—' '—' '—' B Existing drainage improvements not shown or in conflict with site plan. '—' '—' '—' C. Site is served by overhead power lines. FRM0010.DH REV. 11/27/90 '—' '—' '—' D. Grading is required to access site, create pad or provide for ultimate street improvement '—' '—' '—' E. Site access visibility problems exist Provide onsite — turnaround or engineered solution to problem '—' '—I L_I F Other Dedication Requirements '-^-' '—' '—' 9. No dedication required. '—' '—' '—' 10 Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8h" x 11" plat map and submit with a title report and the required processing fee All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: Dedication completed, Date By.. Improvement Requirements '—' '—' 11 No public improvements required. SPECIAL NOTE' Damaged or defective improvements found adnacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy. '—' '—' '—'12. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are' Improvement plans signed, Date. by:. FRM0010 DH REV. 11/27/90 I—I I—I I—I 12. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit Future Improvement Agreement completed, Date By: '—' '—' '—' 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). 14 No grading required as determined by the information provided on the site plan. '—' '—' '—' 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE; The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits Grading Inspector sign off. Date. by Miscellaneous Permits '—' '—' 16. Right-of-Way Permit not required. I—II—II—I 17> Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: Sewer Permit is not required. Sewer Permit is required. A sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. '—' '—' 20 Industrial Waste Permit is not required. FRM0010 DH REV. 11/27/90 ' ' I I I I I* '—' '—' '—' 21. Industrial Waste Permit is required Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Building Permits. Permits must be issued prior to occupancy. Industrial Waster Permit accepted - Date • By. Fees Required D Ni/ft 27 Park-in-Lieu Fee Quadrant Fee per Unit: Total Fees: D M/£| 23. Traffic Impact Fee Fee Per Unit: Total Fee 24. Bridge and Thorough fare Fee Fee Per Unit: Total Fee. 25. Public Facilities Fee required D N//Q 26. Facilities Management Fee Zone: _ Fee D N!//} 27. Sewer Fees Permit No. _ EDU's Fee: _ n K/A 28. Sewer Lateral Required: ' Fee: _ D 29. REMARKS: ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY : S.SCHEDELJL DATE : 21 bEC FRM0010 DH REV. 11/27/90 ' f\ COMMERCIAL/INDUSTRIAL APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT CITY OF CARLSBAD APPLICATION: NEW (CHECK ONE) REVISED V BY BUILDING P.C. NO. APPLICATION NO _ INDUSTRIAL CLASS _ DATE It Signature at/City Representative APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT A. GENERAL APPLI CANT- JA^/OZ, SITE ft AA /AtC ADDRESS; <&7' TYPE OF BUSINESS; APPLICANT'S ADDRESS: \ f 8. WASTES AND PROCESSING (Check where applicable) Domestic W^ste Only Industrial Waste |_J Industrial Waste NOT Discharged to Sewer Discharged to Sewer GENERAL DESCRIPTION/ OF WASTE (Chemical and Physical Characteristics of proposed waste)' GENERAL DESCRIPTION OF PROCESS (If Applicable). C. WASTES TO-flE DISCHARGED TO SEWER: WASTE: (Check One) TREATED: UNTREATi K//JQUANTITY- AVERAGE (Daily) MAXIMUM GPD GPD (Gallons Per Day) APPLICANT OR REPRESENTATIVE OF FIRM: TITLE Ofy^ ^U SIGNATURE: 7 (Print DATE: artment January 2, 1991 Robynn Long Ware & Malcomb Architects 6125 Cornerstone Court San Diego, CA 92121 INDUSTRIAL WASTE DISCHARGE PERMIT APPLICATION NUMBER 796 TAYLOR MADE GOLF 2271 COSMOS COURT This letter is to inform you that glues, solvents and machines oils, if any, are prohibited from the sewer system Taylor Made Golf may be required to submit a wastewater discharge permit application depending on the production processes and wastes generated Please send further information, such as the quantity and characteristics of any chemicals or machine oils that may be discharged into the sewer If you have any further questions, feel free to call me at 438-1161, extension 4354, or Chris Smith at the Enema Water Pollution Control Facility at 438- 3941 Sincerely, CAROLYN WEAVER Engineering Technician II CWrz Chris Smith 2075 Las Palmas Drive Carlsbad California 92009-4859 (619) 438-1161 HAZARDOUS MATERIALS QUESTIONNAIRE Business Name Contact Person Telephone {Mailing Address (7 City State Zip Plan File # Mailing Address City State 2p Plan File # PART I. FIRE DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION. OCCUPANCY CLASSIFICATION Indicate by circling the item whether your business will use process or store any of the following hazardous matenals If any of the items are checked off applicant must contact the Fire Department-Hazardous Matenals Management Division 525 B Street Suite 705 San Diego CA 92101 Telephone (619) 533 4400 prior to plan submlttal Organic Peroxides 10 Oxidizers 11 Pyrophoncs 12 Unstable (Reactive) Matenals 13 Water-Reactoves 14 1 Explosive or Blasting Agents 2 Compressed Gases 3 Flammable or Combustible Liquids 4 Flammable Solids Cryogenics Highly Toxic or Toxic Matenals Radioactves Corrosives Other Health Hazards HAZARDOUS MATERIALS MANAGEMENT DIVISION,PART II. COUNTY OF SAN DIEGO HEALTH DEPARTMENT CONTINGENCY PLAN REVIEW If the answer to any of the questions is yes applicant must contact the County of San Diego Hazardous Matenals Management Division 1 255 Impenal Avenue 3rd floor San Diego CA 92138 Telephone (619) 338-2222 prior to the Issuance of a building permit YES NO / (FEE MAY BE REQUIRED) . Is your business type listed on the reverse side of this form? Will your business dispose of Hazardous Substances or Medical Wastes in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons 500 pounds or 200 cubic feet of compressed gas? Will your business use an existing or install an underground storage tank? Will your business store use or handle carcinogens reproductive toxins or Acutely Hazardous Matenals7 6 I I I T win your business be located within 1 000 feet from the outer boundary of a school and handle Acutely Hazardous Matenals? PART III. SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes applicant must contact the Air Pollution Control District 9150 Chesapeake Dnve San Diego CA 921 23 Telephone (619) 694 3307 prior to the issuance of a building permit YES NO 'Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution Control Distnct Permit Categones on the reverse side of this form? (ANSWER ONLY IF THE ANSWER TO QUESTION 1 IS YES ) Will the subject facility be located within 1 000 feet of the outer boundary of a school (K thru 12) as listed in the current Directory of School and Community College Districts published by the San Diego County Office of Education and the current California Pnvate School Directory compiled in accordance with provisions of Education Code Section 33190? Briefly describe nature of the intended business activity Name of Owner or Authorized Agent Signature of Owner or Authorized Agent I declare und§r pe true and correct DO NOT WRITE BELOW THIS LINE ury ^at to the best of my-knowl d belief the responses made herein are FIRE DEPARTMENT OCCUPANCY CLASSIFICATION. BY I/^ Date EXEMPT FROM PERMIT REQUIREMENTS COUNTY HMMD APCD APPROVED FOR BUILDING PERMT BUT NOT FOR OCCUPANCY COUNTY HMMD APCD APPROVED FOR OCCUPANCY COUNTY HMMO APCD APCD (10 90) DISCLOSURE REQUIREMENTS FOR Hazardous Materials CITY OF SAN DIEGO BUILDING INSPECTION DEPARTMENT 1222 FIRST AVENUE MS301 SAN DIEGO CA 92101 CALL FOR APPOINTMENTS AND INFORMATION (619) 236-6270 INFORMATION BULLETIN 116 August 1990 The following are guidelines to help the building per nut applicant determine whether they need to comply with the hazardous materials reporting requirements For more information, contact the City of San Diego Building Inspection Department at (619) 236-6270 or the individual agencies listed below I NON-RESIDENTIAL BUILDING PROJECTS ONLY These requirements apply to non residential construc- tion projects only Applicants for residential projects do not need to fill out the questionnaire described in Section III of this bulletin n TIME REQUIRED Applicants for non residential construction permits are advised to determine in advance, before applying for permits from the City of San Diego Building Inspection Department, whether their project will require hazardous materials review This review can be completed by contacting the admin istenng agencies for specific information City of San Diego Fire Department Hazardous Materials Manage ment Division at (619) 533-4400, Air Pollution Control District at (619) 694-3307, and the County of San Diego Department of Health Services Hazardous Materials Management Division at (619) 338-2222 The approval process from the administering agencies can be lengthy HI QUESTIONNAIRE MUST BE COMPLETED Applicants for all non residential projects must fill out the Building Inspection Department Hazardous Mate rials Questionnaire Completed questionnaires must be included with the plan set at the time of submittal for commercial or shell buildings If all the questions on the form are answered "no,"it can be submitted with the permit application to the City of San Diego Building Inspection Department and pro- cessing can proceed If there are "Yes" answers to any of these questions, the applicant must contact the proper administering agency for review and approval This review and approval process must be completed prior to submittal of the permit application for Part I of the questionnaire (Fire Department Hazardous Materials Management Divi- sion), and prior to permit issuance for Parts II and III (County of San Diego Department of Health Services Hazardous Materials Management Division and Air Pollution Control District) a Fire department review The City of San Diego Fire Department's Hazardous Materials Management Division requires review if the applicantorfuturebuildingoccupant will use, processor store any hazardous materials The purpose of the re viewistoclassify thebuildingm accordance with Section 901(a) of the Uniform Building Code, and to ensure compliance with provisions of the Uniform Fire Code b Health department review The County of San Diego DepartmentofHealth Services Hazardous Materials Management Division requires review if the applicant or future building occupant will handle a hazardous material or a mixture containing a hazardous material under the following conditions 1 In a quantity at any one time equal to or greater than a total weight of 500 pounds, or a total volume of 55 gallons, or 200 cubic feet at standard temperature and pressure for compressed gas (See Section VII for Haz ardous Material definitions) 2 Or any quantity of the Acutely Hazardous Materi- als listed in Section VII of this handout Note A mixture that contains one percent or more of a hazardous ingredient is a hazardous material A mixture that contains 0 1 percent or more of a carcinogen is a hazardous material For more information or appointments, call ^619) 338 2222 c APCD Review The Air Pollution Control District requires a review for certain types of businesses, especially when the project is within 1,000 feet of a school and may emit air con- taminants, or under other conditions as identified on the APCD's questionnaire For more information on projects within 1,000 feet of schools, see Section V of this Information Bulletin For more information or appointments from the Air Pollution Control District, call 694-3307 IV WHO CAN SIGN QUESTIONNAIRES The questionnaires must be signed by the owner, lessee, tenant, or an agent of any of these V PROXIMITY TO SCHOOLS If the proposed business is going to handle any acutely hazardous material listed in Section LX and will be within 1,000 feet of the outer boundary of a school, a Risk Management and Prevention Program must be imple mented under terms of Section 65850 2(c)of the California State Government Code A school is defined in the Health and Safety Code, Section 42301 9(a), as a school for students in kinder- garten through grade 12 A Hazardous Materials Questionnaire from the County of San Diego Department of Heal th Services must al so be completed Approvals must come from the Hazardous Materials Management Division of the Health Depart IN 5116 (Rev 8-90)