2271 COSMOS CT; ; CB940208; Permit
03/24/94 12 38 BUILDING Page 1 of 1 Job Address 2271 COSMOS CT PERMIT permit No CB940208 Project No A9400300 Development No Valuation 16,352 Construction Type VN Occupancy Group B-2 eer^nr Description 3 OFFICE BLDG IN WAREHOUSE Appl/Ownr INTERNATIONAL STORAGE 1943 FRIENDSHIP DRIVE #F EL CAJON, CA 92020 ..... - Lot# ***Fees Required ****** * * 619 90, , - qq,931-1991 p- , ^Fees/Collected & Credits Status ISSUED Applied 02/28/94 Apr/Issue 03/24/94 Entered By MDP *** 1,653/00 -_ / 00 \ Fees Adjustments, N Total Fees ' Fee description --------------------- ~------ -^— •— — _ Building Permit •' -"•"'.' / X : Plan Check ''• (' \\ I -.. ". Strong Motion Fee 1 '"^' I ,.\ '. Enter Number of EDU's - WaterVFee:/> ' Enter "Y" to Autocalc License-Tax' -X (Lie Tx)\ C F D ' '• ^-^ '-,'' . , Total .CrecJits Total ;Paymehts;;'\ -.. Balance. Due"-' 00 19800 1,45500 fee Data ~J Pv D (TIF CFD Fund) :-r-PEnter Bridge Fee \ •. '' ^ - * BUILDING TOTAL \ vv . • '; j '' . Enter "Y" for Plumbing Issue' Fee'7 > • - Enter "Y" for Electric Issuer-Fee'"'1 > ; • Remodel/Alter Per AMP " •> * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Each Exhaust Fan C * MECHANICAL TOTAL - °° 100 25 65° 180 117 3 36°298275 HI 103 143 159° 10 25 35 15 13 28 00 00 °° 00 00 Y °°00 °0 00 °°N 00 Y 00 °°00 Y 00 00 F^LXPPROVAL SNSP. A-/ DATE */<'«<' CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161 PLICATION City of Carlsbad Building Department 2075 Las PaImas Dr , Carlsbad, CA 92009 (619) 438-1161 I PERMTTTYPfc ~~AD Commercial U New Building pCTenam Improvement ' B D Industrial D New Building D Tenant Improvement C D Residential D Apartment D Condo D Single Family Dwelling D Addition/Alteration D Duplex D Demolition D Relocation D Mobile Home Q Electrical O Plumbing D Mechanical D Pool D Spa D Retaining Wall D Solar D Other 2. PROJECT INFORMATION PLAN CHECK NO f ty- Z. O 8 5935 Q2/23/<? J001 01 C,2 C- RMT 1*8.00 FOR OFFICE USE ONLY Address 2,Z?tNcarcst Cross Street Building or buite No ^djfq^ Lot NLEGAL DESCRIPTION Subdivision Name/Number Phase No CHECK BELOW Ih bUHMll I bL> D 2 Energy Calcs Structural Calcs D 2 Soils Report D 1 Addressed Envelope ASSESSOR S PARCEL EXISTING USE PROPOSED USE DESCRIPTION OF WORK SQ FT er QFt^l <-<& # OF STORIES CUIMIALJ (.11 uiiierent irom applicantj ADDRESS /f yCj brt- CITY STATE C /a- ZIP CODE DAY TELEPHONE CONTRACTOR /JS'AGENT FOR CONTRACTOR UOWNTjR U AtiENT FOR OWNER4 APPLICANT NAME CITY STATE ADDRESS ZIP CODE DAY TELEPHONE 5 PROPERTY OWNER NAME -7>ry/o/t_ CITY ADDRESS ^>? / STATE f (^. ZIP CODE ^Q-gy ? DAY TELEPHONE C (<J - 131' 6 CONTKAtTHJK CITY STATE STATE L1C # UKsltiNER NAMh CITY ADDRESS /9l/ ZIP CODE f3- IJCENSE CLASS DAY TELEPHONE ^ --tf ' CHY BUSINESS LIC # STATE ZIP CODE DAY TELEPHONE STATE UC # WOKKliKS' workers Compensation Declaration I hereby allirm that 1 have a certihcate ot consent to sell insure issued by the Director oiTnaustrjal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab C) INSURANCE COMPANY POLICY NO EXPIRATION DATE Certificate ot Exemption I certify that in tne performance or the work lor which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION Owner Builder Declaration I hereby affirm thatlam exempt Trorn the Contractor's License Law lor the following reason D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? D YES IK-NO Is ihe applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 D YES £3 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES BLNO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT IIAS MET OR IS MEETING TIIE REQUIREMENTS OF T1IF. OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTOOL DISTHICT 9 CONS'l'HUCJUON LENDING AGENCY I hereby atlirm tnat there is a construction lending agency tor the performance ot the work tor which this permit is issued (Sec 3097(0 Civil Code) LENDERS NAME LENDER'S ADDRESS 10 APPLICANT CERTIFICATION 1 certify that I have read the application and state that the above information is correct 1 agree to comply with all City ordinances and State laws relating to building construction I hereby authonze representatives of the City of Carlsbad to enter upon the above mentioned property foi inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMIJSS THE CITY OF CARI.SBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF HIE GRANTING OF THIS PERMIT OSIIA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stones in height Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within 365 days from the date of such permit or if the building or work auihonzed by such permit is suspended or abartjjpljic^i at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code) APPLICANTS SI DATE WHITE File YELLOW Applicant PINK. Finance j f CITY OF CARLSBAD INSPECTION REQUEST PERMIT^ CB940208 FOR 05/02/94 DESCRIPTION: 3 OFFICE BLDG. IN WAREHOUSE TYPE: ITI JOB ADDRESS: APPLICANT: CONTRACTOR: OWNER: 2271 COSMOS CT INTERNATIONAL STORAGE PHONE: PHONE: PHONE: INSPECTOR AREA TP PLANCKtf CB940208 OCC GRP B-2 CONSTR. TYPE VN STE* LOT: 619 931-1991 REMARKS: MH/MIKE SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: —RELATED PERMITS— CD 19 29 39 49 PERMIT# TYPE CB880631 ELEC CB931287 SIGN SE940025 SWOW AS940018 ASTI LVL DESCRIPTION ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical STATUS EXPIRED ISSUED ISSUED ISSUED ACT COMMENTS ***** INSPECTION HISTORY ***** DATE DESCRIPTION 042694 Final Combo 042294 Final Combo 042094 Frame/Steel/Bolting/Welding 042094 Rough Electric 041394 Interior Lath/Drywall 041394 Frame/Steel/Bolting/Welding 040894 Frame/Steel/Bolting/Welding 040894 Rough Electric 040194 Frame/Steel/Bolting/Welding 040194 Rough Electric 040194 Rough/Ducts/Dampers 040194 Frame/Steel/Bolting/Welding 033194 Rough Electric 033194 Frame/Steel/Bolting/Welding ACT CO NR CO AP AP AP PA AP NR NR NR NR PA NR INSP TP PK TP TP TP TP PK PK TP TP TP TP TP TP COMMENTS SEE JOB CARD NO SUP/WIRNG INC/STAIR TOEKIX ND REV ON CEIL JOIST SPANS WALLS & CEILING DROP N/INCL 10X10 OFFICE AS PE CORR N/INCL 10X10 OFFIC CORR ON JOB CARD WALLS l, NO RESPONSE/BLDG LOCKED FINAL ROUGH APPR @ FRAME ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 56O-1463 JURISDICTION PLA.N CHECK NO 94-g.Qfi SET PROJECT ADDRESS ^JL \ I GOsS\TlO£ Ct PROJECT NAME I>f\ \ CCl Or 0 TT I C C <-, M A i i "i r>T>T T p '. v'T1 B~'J JURISDICTION PLAN CHECKER QFILE COPY QUPS QDESIG\ER Tne plans transmitted herewitn nave been corrected where necessary and substantially coTiply with the jurisdiction's building codes The plans transmitted herewitn will substantially comply with tne jurisdiction's building codes when Timor deficien- cies identified are resolved and checked by building department staff The plans transmitted herewitn have significant deficiencies identified on the enclosed check list and should be corrected and resubrnitted for a complete recheck. The cneck list transmitted herewith is for your information Tne plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of the cneck list is enclosed for the jurisdiction to return to the applicant contact person { The applicant's copy of the check list has been sent to Esgil staff did not advise the applicant contact person that plan check has been completed Esgil staff did advise applicant been completed. Person contacted the plan check has CjQV Date contacted; REMARKS: Telephone 3 By _ ESGIL CORPORATION DGA D CM I COvAv? AV Enclosures: ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 56O-1468 JURISDICTION PLAN CHECK NO _ SET JL 0 PROJECT ADDRESS <2-1"l ( '^ PROJECT NAME Lv\ ~( C'Cl Or v J T" i C f /AY\ T ^ T- V, [JURISDICTION "QPLAN CHECKER [jFILE COPY QUPS QDESIGNER D , — - I _ I D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with tne jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The cneck list transmitted herewith is for your information. Tne plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to. 194-5 El GQ IOY\"^.i [ | Esgil staff did not advise the applicant contact person that plan check has been completed. |H Esgil staff did advise applicant that the olan check has been completed. Person contacted: " Date contacted; REMARKS 318 Telephone - 017*2. By -I JA/XdJL ^X( ESGIL CORPORATION 3(l4|?<{ DGA Den DPC Enclosures: ClTV OF •" t -ovn bEachof ^*^^i ~^ "TVi ( Wr^1_^ * ^ _-* • - ' — •• ~— — •f iff Afe QJ? u;ie ^I^ 7 "T\\ 10^cAcicvK-er HfVrt Y\is a 01 of f)e T ..--,..,; 17-/V ObC , bf rrmsls+evii' c.jornl fvie H Qtw\ riai OTXP 0/1^(uu 0/1^0015. v/a iCS v Hfl'd force or fiam^e-f ff.vi i Q(?< cm -¥\\e o /Q- ca\\<. jr^r >4-xo \Aggc\er 4-ioor coewc"Yv/"5 o-f -f\l<f "plows.. A: Gx(o o-f\ C.ft ^ direct i mi as 4Vle -P nrvr-\\e Vi - — ^._f ~ gj.UYAg u is red uce Snrtm QYV -nig. olar\<>T(33'ri uoalls ~o - ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE ?}/ 7 JURISDICTION CARLSBAD ^JPLAN CHECKER — QFILE COPY PLAN CHECK NO 9A"'"'2.Q& SET i- QUPS ^ ^ QDESIGNER PROJECT ADDRESS /2-/L~]\ " ' ' PROJECT NAME D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified : are resolved and checked by building department staff. D Tne plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to":'" EA Ch > HH Esgil staff did not advise the applicant contact person that plan check has been completed^xxep-t by ^r\OL\l r~~\ Esgil staff did advise applicant that the plan check has — been completed. Person contacted:^ _ Date contacted: Telephone REMARKS: Byt, 'AaGAC fU^/ll^^MAV Enclosures: ESGIL CORPORATION «,[{/ 94- DGA LJCM D PC PLAN CORRECTIOH SHEKT TENANT IMPROVEMKNT C\ A f) /*y£LFLAN CHECK NO.; ^^-V-" ^-{JC.2 Date plans received by jurisdiction JURISDICTION; CARLSBAD _ CLlQ-Ql 94 TO- Date plans received by Esgil Corporation S/l/94- Date initial plan check completed ; CA Qaag^ 5/7/ 94 BV PROJECT DATA Applicant contact person OCCUPANCY: BUILDING USE: FOREWORD: PLEASE READ TYPE OF CONSTRUCTION: Plan check is limited to technical requirements Q"ttX_\ NCLO WQCX. contained in the Uniform Building Code, UniformrbJACTUAL AREA: Plumbing Code, Uniform Mechanical Code, National ALLOWABLE AREA: Electrical Code and state laws regulating energy conservation, noise attenuation and access for the STORIES: handicapped The plan check is based on regulations enforced by the Building Inspection HEIGHT: Department You may have other corrections based on laws and ordinances enforced by the Planning SPRINKLERS: Department, Engineering Department, Fire Department or other departments Code sections cited are OCCUPANT LOAD: ~7 based on the 1991 UBC ^ The circled items listed need c larif ication, modification or change All items must be REMARKS: satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheek process, note on this list (or a copy) where each correction item has been addressed, i e . plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. LIST NO Al CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1991 UBC 0 0 Q Please nake all corrections on the original tracings and submit tvo new sets of prints, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-11.68 Please nake all corrections on the original tracings and subnit tvo new sets of prints, to The jurisdiction's building department Indicate on the Title Sheet of the plans, the name of the legal owner and nane of person responsible for the preparation of the plans Section 302(d) Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code Plans and .calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions Please include the California license number, seal, date of license expiration and date plans are signed . Business and Professions Code -fSiS &9PU&.S TO ArLL Srt€ET4> G» Provide the correct address and suite number of tenant space on the plans Section 302 (d) Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled Section 302 When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy Please provide complete details to show the building with comply Section 502 UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) vithin the building. On the first sheet of the plans indicate Type of construction of the existing building, -procont and proposed occupancy c3at tif ications of-the roaoddl area and tho occupant, lood of -the—M»e4<a—a*e»e—and the—floor »herc the •tenant improvement IB 1 seated Provide a note on the plans indicating if any hazardous materials v,ill be stored and/or used vithin the building vhich exceed the quantities listed in UBC Tables 9-A and 9-B A conplete description of the acti\ities rind processes that vill occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible The building official may require a technical report to identify and develop methods of protection from hazardous materials Section 901(f) If control areas are used for exceeding the exempt amounts of hazardous materials from -•-Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation Section 404 The number of control areas within a building used for retail/wholesale stores shall not exceed two, the number of control areas in buildings with other uses shall not exceed four Footnote 1, Tables 9-A and 9-B The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage" Footnotes 2 and 3, Tables 9-A and 9-B Provide a statement on the Title Sheet of the plans that this project shall comply with •rTitle 24 and 1991 UBC, UMC and UPC and 1990 NEC Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered Draw the plans to scale and indicate the 'scale on the plan Section 302(d) Indicate the use of all spaces adjacent to the area being remodeled or improved Show any existing fire rated area separation vails, occupancy separation vails, demising vails, shafts or rated corridors Identify and provide construction details for proposed new fire rated walls Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire vails, floor- ceiling assemblies or roof-ceiling assemblies X X X X X X X Identify existing vails to be removed, existing vails to renain and proposed new vails Identify bearing vails, non-bearing vails, and shear vails Show safet> glazing in the following locations, per Section 5A06(d) a Where the nearest edge of glazing is within a 2u-inch arc of either side of a door in a closed postion (unless there is an intervening vail between the door and the gla^ng or if the glazing ^s 5'-0" or higher above the valking surface) b Glazing greater than 9 square feet with the botton edge less than 18" above the floor and the top edge greater than 36" above the floor (unless the glazing is more than 36" horizontally avay from valking surfaces or if a complying protective tar is installed) c Glazing in shover and tub enclosures (including vindovs within 5 feet of tub or shover floor) Provide a section view of all new interior partitions Shov (a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and appro'^al number or indicate "to be ICBO approved" (b) Method of attaching top and bottom plates to structure (NOTE Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load) (c) Wall sheathing material and details of attachment (size and spacing of fasteners) (d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing Provide notes and/or details to show that the floor and vail finish in toilet rooms aresurfaced with a smooth hard non-absorbentmaterial extending five inches up the wall Similar surfacing shall be provided on the walls from the floor to a height of k feetaround' 'urinals and"" within "vater closetcompartments Section 510(b) Note on the plans "All interior finishes must comply with Chapter kt of the UBC" Specify "Class flame spread rating (minimum) for " Note on plan that suspended ceilings shall comply with UBC Tables i»7-A and 23-P In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s f and no horizontal diaersion exceeds 60 L F (if space has sprinklers, then 3,000 s f. and 100 L F ) Section 2516(f) X In buildings having floors and roofs of wood frame construction, other than dvelling or hotel occupancies, draft stop the ai ea between the ceiling and roof abo\e so that no concealed space exceeds 3,000 s f and no horizontal dimension exceeds 60 L F (if space has sprinklers, then 9,000 s f and 100 L F ) Section 2516(f) Storage areas exceeding 1000 sq ft in connection vith vholesale or retail sales shall be separated from the public area by a one-hour occupancy separation If the entire building has an autoMtic sprinkler s\stem, then the occupancy separation need not be provided Section 702(c) An automatic sprinkler sjstera shall be installed in rooms used bv the occupants for the consumption of alcohol and in accessory uses vhere the total area of such unseparated rooms and assembly uses exceeds '>000 square feet Section 3802(c) 32 ) The tenant space and new and/or existing facilities serving the remodeled area nust be accessible to and functional for the physically disabled See tht attached correction sheet Title 2k, Part 2 The vidth of the required level cirea on the side into which doors swing shall extend 2k inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors Section 2-330U, Title 2k Specify lever-type hardware for passage doors on floors accessible to the disabled Section 2-330^, Title 2k If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan Section 705(c) A ^-hour- occupancy separation is-- required between occupancy and the _occupancy Table '>-B Ducts penetrating occupancy or area separation vails must have fire dampers Section 4306 (J) In areas where the occupant load exceeds two exits are required See Table 33-A Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) Exits should have a minimus separation of one- half the maximum overall diagonal dimension of the building or area served Section 3303(c) 7/8/92 X x The maximum number of required exits and their required separation must be maintained until egress is provided from the structure Section 3303(a) Rooms vith more than 10 occupants may have one exit through one adjoining room Revise exits to comply Section 3303(e) Exit signs are required whenever tvo exits are required Show all required exit sign locations Section 331** (a) Show that exits are lighted vith at least one foot candle at floor level Section 3313(a) Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits Note on the plans "All exits are to be openable from inside without the use of a key or special knowledge" In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" This signage is only allowed at the main exit Section 3304(c) Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door sving of-..; 90 degrees Maximum leaf width is A feet Section 330*»(f) fUli /VPPUEb "To TuOO -2.10R-Y X Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area Section 330fc(b) Applies to door(s) Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access) Section 3304(i) Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half, of. the required, corridor width when in "any position. Section 3305(d) Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area Section 3304(h) Provide panic hardware in Group A,E,H-l,H-2,H-3 and I occupancies Chapter 33 Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware Section Corridors must provide continuous protection to the exterior of the building Interruptions by an intervening room as not permitted Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms Section 3305 Corridors and exterior exit balconies serving 10 or raore occupants must be a. minimum UU inches vide and 7 feet high to the lo.est projection Corridors serving l«ss than 50 occupants nay be a miniDun of 36 inches in width Section 3305(b) When tvo exits are required, dead end corridors and exit balconies are 1 united to 20 feet Section 3305(e) Corridors serving 30 or more occupants shall have vails and ceilings oi one-hour construction Show compliance or clearly show on plans which of the following exceptions has been satisfied a Corridors greater than 30 feet wide vhen the occupants have an exit independent from the corridor Exterior balconies sides of exterior exit d. Corridor vails and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing; Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet in height need not be fire resistive, provided they are constructed in accordance with Section 1705 and are not more than three fourths of the floor- to-ceiling height Section 5305 ig)_,-.. Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100 Section 3305(g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc ) Section 3305(g), Exception 5 is applicable only for corridors on one floor, the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels 5/28/92 . If non-rated corridors are used per Section 3305(g), Exc 5, provide a reference to the corridors on the floor plan, noting 1 Corridors are non-rated per Section 3305(g), Exception 5 2 Smoke detectors shall be maximum 30' on center 3 Pover supplv shall be dedicated branch circuit Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, vith a lock-on device If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated fron adjacent spaces by a demising vail constructed as for a one-hour corridor vail Clearly show vhere the non-rated corridor system terminates and a rated corridor system commences One-hour fire-rated corridors shall have interior door openings protected by tight- fitting smoke and draft control assemblies rated 20 minutes, except openings in interior vails of exterior-xexit balconies Doors shall be maintained self-closing or be automatic- closing by action of a smoke detector per Section 4306(b) Doors shall be gasketed to provide a smoke and draft seal vhere the door meets the stop on sides and top Section 3305(h) Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor Such openings shall be protected by fixed glazing listed and labeled for a fire- protection rating of at least 3/4-hour Section 3305(h) Show rated corridors, lobbies, reception or t foyers cross-hatched on_the floor plans Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations Section 3305(g) r Show the location of fire dampers Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor ceilings Combination fire/smoke dampers are required at duct penetrations of rated corridor vails Section 4306(j) If a room vith an exhaust fan h&s a door opening into a rated corridor, show how make- up air vill be provided to the room The door cannot be undercut, nor can a louver in the door be proMded Section 3305(h)l If building exceeds tvo stories and has an elevator opening into a rated corridor, show how the snoke and draft control provision of Section 3305(h) will be net Either provide a separated elevator lobby or a second door at the elevator entry neeting the provision Section 3305(j) If a second door is provided at th« elevator entry, note that it vill be readily openable from the car side vithout a key, tool or special knowledge or effort Section 5106 New provisions in Chapter A3 of the 1991 UBC require special treatment of penetrations at f ire-resistive assemblies Provide typical details on the plans showing how the fire- resistive integrity will be maintained at the following conditions (Include the manufacturers' names and ICBO numbers (or equal) for any sealant) A THROUGH-PENETRATIONS (through 1.he entire assembly) 1 Fire-resistive bearing vails and/or vails requiring protected open:ngs shall have penetrations protected vith through- penetration fire stops having an F- rating, T-rating or complying with UBC Standard 43-1, depending on their locations, sizes and combustibility 2 Fire resistive floor/ceiling assemblies shall have penetrations protected vith through-penetration fire stops having and F-rating, T-rating or complying vitn UBC Standard 43-1, depending on their sizes, combustibility and whether the penetrations axe in vails above B MEMBRANE-PENETRATIONS (through only one side of an assembly) 1 Fire-resistive walls (whether bearing or not and whether requiring fire protected openings or not) shall have penetrations protected with membrane-penetration f.re stops having -an F-rating,-or complying with UBC Standard 43-1, "depending on their size and combustibility Limited steel electrical outlet boxes (not exceeding 16 sq in , nor more than 100 sq in for any 100 sq ft of wall) require no protection 2. Fire-resistive ceilings shall..have no penetrations, except for noncombustible sprinkler pipes and steel electrical outlet boxes as described above NOTE The plans should indicate the various fire-stop ratings required for all penetrations Provide a note on the plans stating "Penetrations of fire-resistive valis, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 4304 and 4305" 8/4/92 Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment) If nonflamnable supply cylinders for medical gas svsteir.s are located inside buildings, shov how they conply vith UBC Section 702(c)4 FTJETRICAL Subnit plan shoving location of all panels Submit panels schedules Subait electrical load calculations Indicate existing nain service size Indicate existing total nain service load Indicate nev additional loads Indicate viring nethod, i e EMT, netal flexALSO, HOUJ \w\u_ Vou &XTEJJO ELJEC To THese Shov. exit signs on the electrical lighting plan(s) As per Section 3313 and 3314 of the 1991 UBC, provide tvo sources of pover to exit signs and e\it illumination Provide receptacle(s) vithin 25' of H\AC units UMC Section 509 f 85 l Provide multiple switch lighting controls per Title 24, Part 6 MECHANICAL NOTE G>K) PL/VMS THAT fiasMttdc mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air vith a total circulation of not less than 15 cubic feet per minute per occupant Section 605 and 705, UBC Provide mechanical plans shoving existing and proposed HVAC equipment, ducts and access to equipment Detail access and working clearances to HVAC equipment Detail disposal of main condensate drainage from air conditioning units (UMC Section 510) Detail overflew (secondary) condensate discharge from air conditioning units that are in a ceiling space (UMC Section 1205)— Fire rated corridors are not to be used to convey air to or from rooms UMC Section 1002 PLtMBDC Provide gas line plans and calculations, shoving pipe lengths and gas demands UPC Section 1219 Provide drain, vaste and vent plans Provide vater line sizing calculations UPC Section 1009 Detail hov floor drain trap seal is to be contained UPC Section 707 (floor drain trap pruning) Shov P & T valve on vater heater and detail drain line route fron P & T valve to the exterior UPC Section 1007(e) Show I/it" per 12" slope on drain and vaste lines UPC Section 407 Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments) UBC Section 605 Note on the plars that new vater c losets and associated flushcneter valves, if any, shall use no Dore than 1 6 gallons per flush and shall neet perfomance standards established by the American National Standards Institute Standard A112 19 2, and urinals and associated flushoaeter valves, if any, shall use no more than one gallon per flush and shall Beet performance standards established by the American National Standards Institute Standard A112 19 2 H & S Code, Section 179 >1 3(b) EKERGT Provide complete energy design calculations, including all existing design and new energy design for this building See attached non- residential energy design checklist For renodels in an existing conditioned space, show that the renodeled space will not use Dore energy than the existing space or show the renodeled space vill conform to latest energy design standards OF Roof counted equipment oust be screened and roof penetrations should be minimized (City Policy 80-6) No viring is permitted on the roof of a building and viring on the exterior of a building requires approval by the Building Official (City Policy) 6/25/93 I0<£All roof -counted equipment shall be concealed from view ProMde structural detailing for the screening <1QS } Please see additional corrections or renarks ^--.*/ that follow ©To speed up the recheck process, note on this list (or a copy) v.here each correction item has been addressed, i e , plan sheet, note or detail nuaber, calculation page, etc Please indicate here if any changes ha\e been nade to the plans that are not a result of corrections from this list If there are other changes, please briefly describe then and vhere they are located in the plans Have changes been made to the plans not resulting fron this correction list' Please check _ Yes _ No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468, to perform the plan check for your project If you have any questions regarding these plan check items, please contact Corporation Ihank you Enclosures 1 2 3 _at Esgil 6/25/93 Uevit 'OW i^L IS CPU OCCL i& * qvr. log '.T\-Vewrl <r JJLXL L-orea mat a v\c\ v\/r -fir spac _QLi li ni:s 01^ SC-T^V y (— f' r - r \cl 0-H-lg.JLJ. nonrv -VV\<f olarvs (o" M ^xxrci-cH y^gcxcicrs rl to tbe .mil J cSTate3o Tbe "too o£lrA , Hm rleC: iQ!^^li !£L b^ 0 4- VVM- OS Z?-VV n TIT QV\Q,T\S T^g. Ce<M Wumv /Vi ^o as \'e;'r( Jo^. n o . x^sr.fc . -! ^T^ir-^ir t i» . • » »*^-f T ^ -1 ySj ^r--f '•% •t--- i * t ^ b O.rea Or "7 s/^v tr uuill be1C QVier ^31. -f4' . ^\ ** »fY\ g. TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction GfrfcLSfe/VD Plan Check No. References to section numbers vith prefix "2" are to Title 24, California Code of Regulation', Part 2 (California Building Code) Prefix "3" is for Part 3 (California Electrical Code) Prefix "5" is for Part 5 (California Pluabing Code) Exemptions clamed for any item shall be requested in vriting and shall include all data needed to determine "unreasonable hardship" as described in Section 2-422 SITE DEVELOPMENT HANDICAPPED PARKING SPACES (a J Pro% ide_ 2-7102(b) b. hand-capped spaces 0 o Space shall be so located that handicapped persons are not compelled to wheel or valk behind parked cars other than his/her own 2-7102(c) Parking space shall be a minimum of 9 ft x!8 ft vith adjacent marked 5 ft loading zone Double space shall be 23 ft _wide Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle 2-7102(c) Maximum slope of parking surface in any direction shall not exceed 1/4" per foot 2-7102(e) Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or vail, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the parking stall). 2-7102(f) | Entrance to parking area (or at each stall) shall have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away. 2-7102(f) If covered parking is provided, then a reasonable portion of the total number of stalls, reserved for the disabled shall also be covered. 2-7102(a) Entrances to and vertical clearances within accessible levels of parking structures shall be 8 ft 2 in. to anystructural member, duct or pipe 2-7102(g) CURB RAMPS ©Curb ramps shall be located wherever pedestrian path crosses curb (2- 7103(a)) b j Curb ramp shall be 48" nin width (2- 7103(b)) with maximum slope of 1 2-7103(d) in 12 A level 48" Bin depth landing is required at top of curb ramps over entire curb ramp vidth 2-7103(d) If no landing is provided, the slope of flared sides shall not exceed 1 in 12 2-7103(d) e ^Surface is to be slip resistant and aVy<—^contrasting finish from adjacent sidewalk 2-7103(f) ©Border markings shall be 12" wide of l/4"xl/4" grooves, 3/4" apart, located at top and sides 2-7103(h) WALKS Site development and grading shall be designed to provide .access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc 2-7101(a) iWalks sloping greater than 5% (1 in 20) ist comply with ramp requirements of Sec 2-3307 2-3325(c) ©Walk width shall be 48" minimum, and shall have slip-resistant surfaces. 2-3325(a) ( d.)The maximum cross slope shall not exceed \~£ 1/4" per foot. 2-3325(a)3 e.jGratings are not allowed _2-3325(b). whenever f.jAt each gate or door a 60"x60" level area Ss-«f is required when the gate swings toward the walk 2-3325(e) g j A 48"x44" deep level area is required vhen the gate swings away from the walk 2-3325(e) )A 24" clear space is required at strike side of gate or door. 2-3325(e) PEDESTRIAN RAMPS ©A path of travel vith a slops greater than 1 in 20 shall be considered a ramp 2-3307(a) rb.)The maximum slope shall be 1 in 12 2-3307(c 1) width shall be 48" minimum A >—^minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more Croup R Occupancies may be 36" when the occupant load is SO or less 2- 3307(b 1) ©The surface of ranps shall be slip- resistant 2-3307(g) OA 60" intermediate landing is required at naxinua ele\ation change of 30" and 72" lending at each change of direction (over 30 degrees) 2-3307(d 1) 0Landings are required at tcp and bottoa of ranps 2-3307(d 1) 'gs)Bottoa landing shall be nininun of 72" •> the direction of tra\el Fig 2-33- 11A )Top landing 2-3307{d 1) shall be 60" x 60" nxr.ioua When door swings onto top landing, depth of landing required is door uidth plus 42" 2-3307(d 1 ) QTop landing shall ha\e 60" mm width when door swings onto the landing, with 24" on strike side of door at exterior ramp, or 18" at interior ranp 2-3307(d 1) )Ramp handrails are required on each side -of ramp, when slope, exceeds 1 in 15 2- 3307(e 1) l.Ramp handrails shall be continuous, .located 30"-34" in height above ranp surface, with 12" extensions beyond top and bottoa, and the ends returned 2-3307(e 1) m.} Handrails shall be 1-1/4" to 2" cross section, spaced minimum of 1-1/2" from vail 2-3307(e 1) 2" high curb or wheel guide rail •'centered 3" + 1" above ramp surface is required on ~ both sides where not otherwise bounded by walls when the ramp exceeds' 10 feet in length. 2-3307(h 1) SPECIAL ACCESS LIFTS Lifts may be provided between levels, in lieu of elevator, vhen the vertical distance between landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health. 2-5107(a) The lift platform shall be of sufficient size to accommodate a wheelchair (30"x48") 2-5107(a) There shall be a level and clear floor area or landing (60"x60") at each level for access to the lift 2-5107(a) HAZARDS Provide 80" headroom from valkvay surface to any overhanging obstruction 2-3326(b) Headroom of maintained for etc 2-522(f) 80" DiniDua shall be valks, corridors, aisles, Protruding objects vith leading edges between 27" and 80" aboie finished floor shall not protrude more than 4" into valks, corridors, etc 2-522(f) Free standing objects nounted on posts betv-een 27" and 80" sbo\e the floor cay project a maximum of 12" 2-522(f) Abrupt changes in le\el exceeding 4" adjacent to v,alks, except betveen valks and adjacent streets or drives, shall be identified by 6" high vaming cuibs abo e v.alk surface 2-3326(a) ENTRANCES AND 7 ENTRANCES, DOORS, VESTIBULES AND COi«IDORS .a.) All prinary entrances to buildings shall be accessible to the handicapped 2-3301(f) ©All required passage doors shall have 32" clear opening at 90 degrees (36" door) 2-330U(f) c.)At least one of a pair of doors shall neet the minimum 32" clear entrance width requirement 2-3304(f) > Threshold shall be no higher than 1/2" above the floor Edge to be beveled with a slope no greater than 1 in 1, if more than 1/U". 330U(i 1) e.JExterior level landing may slope up to 1/4" per foot in any direction for surface drainage 2-413 f .^Door hardware shall be of the lever or 'push type, mounted 30" to 44" above the floor and be' operable with a maximum effort of 8 5 Ibs for exterior doors and 5 Ibs for interior doors. 2-3304(c), 2- 3304(i 2) g7\The lower 10" of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors 2-3304(i 3) h.JBuilding entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan The symbol shall be a white figure on blue background 2-522(b) At turnstile, provide an access gate, 32" clear width opening, vithin 30 feet of turnstile 2-3304(i 4) ©There shall be a clear area on each side of door, 60" deep in direction of door swing and 44" deep in opposite direction of door sving. 2-3304(i 1) Width of clear area on the swing side of the door shall extend 24" past strike janb for exterior doors and 18" past strike ja=b for interior doors 2-3304(i 1) The space between two consecutive doors (vestibule) shall provide a ninuBua of 48" clsar depth between the open doorand a. second closed door Doors in a series at a \estibule shall swing in the saae direction, or away frca the space between then 2-3304(i l) For corridors over 200 feet long, see special requirements of Sec 2-3305(b)2 FLOOPS Floors of a given story shall be a cocsaon level throjgnout or shall be connected by pedestrian ranps, passenger elevators, or s pecial access lifts 2-522(e) STAIRWAYS NOTE: Only applies where disabled access is provided or required to other levels. Treads shall have smooth, rounded evposed edges and be slip resistant 2- 3306(s) Nosirg shall not project more than 1-1/2 inches past face of the riser below 2-3306(s) Risers shall be sufficiently solid 2-3306(s) The upper approach and lower tread of each flight of stairs shall be narked yith a contrasting colored strip 2" in 2-3306(r) On exterior stairs, each tread shall be marked as noted above 2-3306(r) Handrails axe required on each side of stairway 2-3306 Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread width beyond bottom nosing and returned to vail/newel post 2-3306(j 1) Handrails shall be 1-1/4" to 2" in gripping cross section and 1-1/2" clear of vail 2-3306(j 1) r Approved stain-ay identification signs shall be located at each flooi level in all enclosed stairva\s in bu:ldings two or nore stories in height The sign shall identify the stairway., indicate whether there is roof access., the floor level, and the upper and low< r terminus of the stairvay The inforcuition shall be presented using ra.sed Arabic nuoerals and ra.sed braille s\—bols which confers to Section 522(b)3 The sign shall be located approximately 5 feet above the floor landing inaed.ately adjacent to the door on the strike side Sigrs shall conply with requirements of U B C Standard No 33-2 ELEVATOPS Provide clear inside ele1 ator car dimensions as required by U B C Section 5103(d) 6 and Title 2U 2-5103(d 1) At least one elevator in buildings 4 or oore stones in height 80" by 54", with a 42-inch -side 'slide door Applies only to high-rise buildings, A/E/I occupancies, 'State-owned buildings, residential Ciire hones, hotels, notels, apartments and condoninivsss Elevator in buildings more than two stories or buildirgs where disabled access is required to upper level(s) 68" by 54", with a niniaiun clear door width of 36" Elevators other than in (b) above serving less than 50 occupants shall have a mimaum irside platforn of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches. Raised Braille carkings and Arabic numerals are required on control buttons and door jambs 2-5103(d 1) SAHHARI FACTT.TTTTC 11 ) TOILET FACILITIES ACCESS a.When located on accessible floors, sanitary facilities shall be Bade accessible to physically handicapped (2-511 l(a)) ©Doorvays shall have 32" minuouo clear opening vidth 2-511 1 c/\There shall be a level area with 60" <-Jclear depth in the direction of the door swing, and a level area with 44" clear depth in opposite direction of door swing 2-511 l(a) MULTIPLE ACCOMMODATION TOILET FACILITIES Provide clear area 60" high - or clear space 56' high 2-511 l(a) djaaeter x 27" x 63" x 27" Doors (other than handicap conpartnent) are not to encroach more than 12" into abo\e nenticned clear space 2-511 l(a) Provide a 28" clear space betveen vater closet and fixture or 32" clear space between vater closet and vail 2-511 l(a) A 48" long clear space is required in front of vater closet A 60" clear space is required vhen the toilet coapartnent has a side door 2-511 l(a) Water closet cospartnent door to provide 32" clear vidth for end entry and 34" clear vidth for side entry Door to be self-closing 2-511 l(a) SINGLE ACCOMMODATION TOILET FACILITIES Water closet shall be located 28" froa a fixture or 32" from a vail 2-511 l(a) Minimus clear space in front of vater closet shall be 48" 2-511 l(a) In an existing building, a single accommodation toilet facility may have a space 36" wide x 48 " long in front of vater closet 2-511 l(a) © © GRAB BARS AT WATER CLOSET One at side 42" long extending 24" in front of vater closet, one at rear 36" long centered on vater closet, both oounted 33" above floor Where a tank- type toilet is used, grab bar may be as high as 36" 2-511 l(a) Bars shall be 1-1/4" to 1-1/2" in diameter with 2-511 l(a) 1-1/2" clearance to vail ©Bar fasteners and mounting support shall be able to withstand 250 Ibs./ft on bending, shear and tension 2-511. l(a) WATER CLOSET Height of water closet seat shall be 17" to 19" above floor. 5-1502 Controls shall be operable with one hand, and shall not require tight grasping, pinching or twisting of the wrist. 5-1502 c } Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor 5-1502 | The force required to activate controls shall be no greater than 5 pounds force 5-1502 a Where urinals are proMded, the rim of at least one shall project 14" from the vail and be located 17" r-axiaum above floor 5-1503(a) @The force required to activate the flush •valve shall be 5 Ibs cajiinua and located U*" caxiaun abo\e floor 5-1503(b) c "^Provide 30" x 48" clear floor space for approach 2-511 l(b) 17 ^LAVATORIES Provide 30" x 48" clear floor space for forvard approach Said clear floor space cay include knee and toe space under la%atory described below 2-511 l(b) ,Pro\ide clear space beneath lavatories " high by 30" vide by 8" dee-3 at top and 9" high by 30" wide by 17" deep at botton fron front of la\atDry (toe space) The ttaximun counter surface height should be 34" 5-1504(a) lot water and drain pipes under •atones shall be insulated. 5-1504(b) dTVaucet controls and operating nechanisn (operable with one hand) shall be of the type not requiring tight grasping, pinching or tvisting of the wrist (such as lever-operated) and an operating force not exceeding 5 Ibs 5-1504(c) self-closing valves are used, they shall remain open for at least 10 seconds 5-1504(c) 18.1 TOILET ROOM ACCESSORIES ^ Mirror botton edge shall be located 40" naximin above floor. 2-511 l(b) Toilet tissue dispensers shall be mounted vithin 12" from the front edge of toilet seat 2-511 l(b) c.)Operating parts of dispensing and disposal fixtures (towels, w<iste, coin slots, etc ) shall be vithm 40" of floor 2-511 l(b) 19ASANITARY FACILITIES IDENTIFICATION On doorvajs leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" diaoeter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color. Unisex facilities shall be identified by the circle vith the triangle superimposed v ithin the circle 2-511 l(a) Date:3/1/94- Prepared byiQU Jurisdiction CARLSBAD VALUATION AND PLAN CHECK ^EE Q 31dg. Dept. D Esgil PLAN CHECK NO. 94-" 3UILDING ADDRESS 2JL"? I GoS.VY\OS Gt APPLICANT/CONTACT BUILDING OCCUPANCY TYPE OF CONSTRUCTION PHONE NO. DESIGNER PHONE CONTRACTOR PHONE - Oil?. BUILDING PORTION 0-W-ic.e rw-i^ TLoo Sir>wOi-fe</ Sfa fc<s Air Conditionine Commercial Residential Res. or Comm. Fire S-orinklers Total Value BUILDING AREA (OO 14-0 &^4- 7D VALUATION MULTIPLIERas 2.S CL5 10, 15? @ e e VALUE 1SOO 350O 5(oOO 1S^ ib^sa. Building Permit Fee $_ Plan Check Fee $s 117. oo COM HCNTS SHEET OF I 7/87 City of Carlsbad DATE • 7 7 ?~ BUILDING ADDRESS Engineering Department BUILDING PLANCHECK CHECKLIST PLANCHECK NO && PROJECT DESCRIPTION \A)&S& J2>¥32- _4 ™ ASSESSOR'S PARCEL NUMBER EST VALUE ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build 1st CHECK By.Date 2nd CHECK By.Date 3rd CHECK By.Date DENIAL Please see the attached report of deficiencies marked with Q Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By.Date By.Date By.Date ENGI FOR QFFICAL USE ONLY AUTHORIZATION TO ISSUE BUIIDING PCRMm ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Right of Way Permit Application D Sewer Fee Information Sheet CONTACT PERSON NAME. ADDRESS PHONE A-4 P \DOCS\CHKLST\BP0001 FRM REV12/1//93 2O75 Las Palmas Dr • Carlsbad, CA 92009-1576 • (619) 438-1161 - FAX (619) 438-O894 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow D Property Lines Easements B Existing & Proposed Structures E Easements C Existing Street Improvements F Right-of-Way Width & Adjacent Streets [U 2 Show on site plan A Drainage Patterns C Existing Topography B Existing & Proposed Slopes Q 3 Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure D 4 Include note "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)" [Per 1985 UBC 2907(d)5] On graded sites, the top of any exterior foundation shall extend above the elevalion of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5) D 5 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION P \DOCS\CHKLST\BP0001 FRM Page 1 Of 4 REV 12/17/93 BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 6 Project does not comply with the following Engineering Conditions of approval for Project No __ Conditions were complied with by _ Date __ DEDICATION REQUIREMENTS 7 Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 1840030 Dedication required as follows Attached please find an application form and submittal checklist for the dedication process Provide the completed application form and the requirements on the checklist at the time of resubmittal Dedication completed by Date IMPROVEMENT REQUIREMENTS D 8a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18 40 040 Public improvements required as follows Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit Attached please find an application form and submittal checklist for the public improvements requirements Provide the completed application form and the requirements on the checklist at the time of resubmittal Improvement Plans signed by Date P \DOCS\CHKLST\BP0001 FRM Page 2 Of 4 REV 12/17/93 BUILDING PLANCHECK CHECKLIST 1stv/ 2nd\/ 3rdv/ D D D 8b Construction of the public improvements may be deferred pursuant to code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $ so we may prepare the necessary Future Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit Future public improvements required as follows Improvement Plans signed by Date D 8c Enclosed please find your Future Improvement Agreement Please return signed and notarized Agreement to the Engineering Department Future Improvement Agreement completed by Date D 8d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code D D D 9a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities (cut, fill import, export) D D D 9b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained pi lor to issuance of a Building Permit Grading Inspector sign off by Date D 9c No Grading Permit required BUILDING PLANCHECK CHECKLIST P \DOCS\CHKLST\BP0001 FRM Page 3 Of 4 REV 12/17/93 MISCELLANEOUS PERMITS 2ndv/ 3rdv/ D D 10 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, trees, driveways A separate Right-of-Way permit issued by the Engineering Department is required for the following Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal D D 11 A SEWER PERMIT is required concurrent with the building permit issuance The fee is noted in the fees section on the following page 12 INDUSTRIAL WASTE PERMIT is required Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of apermrt Industrial waste permit accepted by Date P \DOCS\CHKLST\BP0001 FRM Page 4 Of 4 REV 12/17/93 ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant (^Calculation based on building plancheck plan submittal Address Bldg Permit Prepared by Date Checked by Date EDU CALCULATIONS: Lst types and square footages for all uses Types of Use O'lf'ir.tL- Sq Ft ^34 ^ '/I&Q EDU's Total EDU's APT CALCULATIONS: Ust types and square footages for all uses Types of Use Sq Ft ADTs Total ADTs FEES REQUIRED: PUBLIC FACILITIES FEE REQUIRED D YES J^NO (See Building Department for amount) WITHIN CFD D YES (no bridge & thoroughfare fee, reduced Traffic Impact Fee) 1 PARK-IN-UEU FEE FEE/UNIT PARK AREA NO UNfTS =S 2 TRAFFIC IMPACT FEE ADTs t. 3 BRIDGE AND THOROUGHFARE FEE ADTs 4 FACILITIES MANAGEMENT FEE EDU's 5 SEWER FEE PERMfT No EDU's FEE/ADT • FEE/ADT. ZONE =S FEE/EDU X FEE/EDU / &~BENEFIT AREA — 7?EDU's / ^X FEE/EDU "9 SEWER LATERAL ($2,500 DEPOSIT) 1 WATER FEE EDU's • '^ X FEE/EDU =$ :$_ / }// TOTAL OF ABOVE FEES* S *NOTE- This calculation sheet Is NOT a comolete Hat of all fees which mav be due P DOCS MISFORMS.BP0001 FRM BEV Plan Check No 9U- PLANNING CHECKLIST Address 2-~CT Planner VAN LYNCH Phone 438-1161 ext 4325 M (Name) Type of Project and Use Zone r AA Facilities Management Zone _ % CFD Legend property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department) c c ca a a a. a. a. GkLl or:nn Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified Environmental Review Required YES NO A TYPE DATE OF COMPLETION Compliance with conditions of approval' If not, state conditions which require action Conditions of Approval Discretionary Action Required YES NO iVl TYPE DATEAPPROVAL/RESO NO PROJECT NO OTHER RELATED CASES Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval California Coastal Commission Permit Required YES _ DATE OF APPROVAL San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA 92 108-1725 (619) 521-8036 Compliance with conditions of approval' If not, state conditions which require action Conditions of Approval __ drac nn CJDD cran an Inclusionaiy Housing Fee required YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Site Plan. Zoning Provide a fully dimensioned site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, nght-of-way width, dimensioned setbacks and existing topographical lines Provide legal description of property, and assessor's parcel number Setbacks , ,/H G Front t)'^ Int Side Street Side Rear 2 Lot coverage 3 Height * 7 cwctf> 4 Parking Additional Comments Required Required Required Required Required Required Spaces Required Guest Spaces Required Shown Shown Shown Shown Shown Shown Shown Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE PLNCK.FRM City of Carlsbad 94051 Fire Department • Bureau of Prevention Plan Review: Requirements Category Building Plan Check Date of Report Friday, March 4,1994 Reviewed by _ Contact Name intn'L storage Address 1943 Friendship Dr #F City, State El Cajon CA 92020 Bldg Dept No 94-208 Planning No Job Name Taylor Made Golf Job Address 2271 Cosmos Ste or Bldg No Approved - The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Disapproved - Please see the attached report of deficiencies Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFD Job# 94051 File# 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121