HomeMy WebLinkAbout2280 PLAZUELA ST; ; 83-51; PermitI hereby affirm that I m licensed under
- provisions of Chapter 9 (commencIng with
Section 7000) of Division .3 .of the Business I and Professions Code, and my license is in
I full force and effect. L -. lic. No. ___________ Class
I hereby affirm that I am exempt from the Contras -tot's Lii.eiise Law fin [lie following ieassn (Sea. 7031.5 Business and Professions Code: Any city or county which re-quires a permit 10 roust mel. alter, improve, demnusli, or
repair any structure, prior toils issuance also requires the ap-yliount for ouch permit to ills a signed cistemunt that he is
licensed pursuant to the provIsions of the Contractor's
- . License Law (Chapter 9 commencing with Section 7000 of
Division 30f the Business and Professions Code) or that is ex-empt therefrom and the basis for the alleged exemption. Any violation of Section 7031,5 by an applicant for a permit sub-Ini.Is thu pptlurit to a doll usually ci eel ifultiti Iliac tiv tieS dred dollars ($500).
I. as owner of the property, or my employees with wages
15 as their solo compensation, will do the work, and the niruc-
tore is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does
5 not apply to an owner of property who builds or improves
thereon and who does such work himself or through his own employees, provided that such Improvements are not lot end-
us ed or offered for sale, if, however, the building or improve- Z mont is sold within one year of completion, the owner-builder
will have the burden of proving that he did net build or Im- prove for the purpose of sale). - -
I, as owner of the property, am excluaively contracting , with licensed contractors to construct the project (Sec. 7044,
Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or [in-proves 'thereon. and who contracts for each projects with a contractor(s) license pursuant to the Contractor's License .Law). -.
0 As a homeowner lam Improving my hsme, and the follow-ing conditions exist:
The work is being performed prior to sale. I have lived In my home for twelve months prior to completion Of this work. -
I have not claimed this exemption during the last three years.
tarn exempt under Sec. ' ,B & P.C.
for this reason .- -
(a,
0
cc
(.7 us 0
D I hereby affirm that Ihave a certificate of consent
to sell.insure. or a certificate of Workers' Compensation Insurance, ore certified copy thereof
(Sec 3800, Labor Code).
POLICY NO. -. - Z
0 COMPANY I- 4 o Copy is filed with the city. U, Z L1.1 0 Certified copy is hereby furnished 0.
0 - - CERTIFICATE OF EXEMPTION FROM (7 WORKERS' COMPENSATION INSURANCE. - A (This section need not be completed if the permit is for one hundred dollars ($100) or less)
I certify that in the performance of the work for which this permit is issued. I shall not employ any
person in any manner so as to become subject to the Workers' Compensation Laws of California
NOTICE TO APPLICANT, If, after making this Certi-ficate of Exemption, you should become subject 10 the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked -
-- I
-r 0 I hereby 'affirm that there is a construction
I - lending agency 101 the performance of the work for cal which this permit is issued (Sec 3097, Civil Code)
Lender's Name' -
L Lender's Address
ri
.a'r flwl I einimir wrei aciliw . RRFtit LIAflIS APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
- CARLSBAD BUILDING DEPARTMENT - APPLICATION & PERMIT -
1200 Elm, Carlsbad, California 92008-1989 (619) 438.5525
.JOB ADDRESS AV. ST. DATE OF AP LICATION
:97 c7'Eg7
RD.
OWNERS.NAME • a,#p OWNER'S PHONE, CONTRACTOR , . , cONcTqfn
1
s:poNE...
V UATION PERMIT NUMBER
ZONE
oWNtrIc MAIIJNC ADDRESS 8' t'c cñ a CONTRACTORS ADDRFSS ., LICENSE NO..
.
PLAN I.D. # LOG USE CODE
LOT I BLOCK SUBDIVISION I' AESSOR P C 0. I -'."-JW-c?3
DESIGNER
DESCRIPTION orwonle
LICENSE ol STANDARD PLAN # BUILDING SO. FOOTAGE
dad c -,,5y€c'c.r/o,I . DESIGNER'SAODRESS . DESIGNERSPHOI1E .
-
/38(C9&9 ' .74LI'1I DOCØ iaiei €3
Not Valid Unless Machine Certified
-
F/P FLReLEV.
YO NO
NO OGP EDU
CENSUS TRACT GP LAND USE PA KING SPACE
(
RES UNITS GRADING PERMIT ISSUED
YO N 0
VELOPMEN1_ AREA
vO N
TV E1
N
0CC LOAD
/
FIRE SPR
vO N
CITY PLUMBING PERMIT - ISSUE QTY. MECHANICAL PERMIT - ISSUE 3'—.x SUMMARY/ACCOUNT NUMBER
-
fEACH . :i FIXTURE TRAP INSTALL FURN. DUCTS UP TO 100.000 BTU 4. BUILDING PERMIT 01-00-00-8220 (01
CHBUILOING SEWER -- - OVER100,000 BTU ' - '
WATER HEATER AND/OR VENT
- SIGN PERMIT 01-00-00-8221
H BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 01-00-00-8806
EACH GAS SYSTEM 1 TO 4 OUTLETS - - BOILER/COMPRESSOR 3-15 HP . TOTAL PLUMBING 01-00-00-8222 J1i ,iJ
EACH GAS SYSTEM 5 OR MORE - . - 'METAL FIREPLACE ,- - - ELECTRICAL 01-00-00-8223 -
EACH INSTAL. ALTER. REPAIR WATER PIPE . VENT FAN SINGLE DUCT - MECHANICAL 01-00-00-8224
- EACH VACUUM BREAKER . MECH EXHAUST - HOOD/DUCTS . MOBILEHOME 01-00-00-8225
- WATER SOFTNER , - RELOCATION OF EA FURNACE/HEATER. ' . - MOBILEHOME PARK INSP --
EACH ROOF DRAIN (INSIDE)
_:___ ' - SOLAR 01-00-00-8226
-. - '-
TOTAL MECHANICAL -
. -
.
/J. '
STRONG MOTION - 80-92-33-0519 10,4
-
- TOTAL PLUMBING ...J ? - FIRE SPRINKLERS -. - 01-OD-00-8227
QTY. i ELECTRICAL PERMIT -ISSUE QTY. SOLAR - ISSUE .
/ PUBLIC FACILITIES FEE 32-00-00-8923
BRIDGE FEE
NEW.CONST EA AMP/SWT/BKR - - k,J3 COLLECTORS . - ... SCHOOL FEE - DISTRICT
- ").PH '. ' 3 PH .
-
STORAGE TANKS Carlsbad 80-92-21-0519
EXIST BLDG EA AMP/SWT/BKR - ROCK TORAGE - ' - / Encinitas - ' - 80-92-22-0519
1 PH - '3 PH -
-
. PUMP - ,- / San Dieguito 80-92-23-0519
REMODEL/ALTER PER CIRCUIT . PLAN CHECK FEE - / - anMarCoS -' ' 80-92-24-0519
TEMP POLE' 20OAMPS
-
OVER 200AMPS ' . - ' - 1 '.
-
TEMP OCCUPANCY 130 DAYS) - , , - / -
TOTAL ELECTRICAL
- -
- -
-
. -
TAL SOLAR TOTAL FEES PAYABLE
Y
- T .
E Every per Mit issued by the hi 1
A
`HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREB xpira I Building Offi&ij, J~60~'Iheprovlsibh!10 I Is *'AN.OSHIA-PER1111111ITAS.111EQUIRED FOR EXCAVATKMS OVER
àEF1TIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE limitation and become null and void. It the budding or work : .-T' 50'0P p€MOLmoN OR CONSTRUCTION OF authorized .DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY ANDAGREE IF A PERMIT IS permit or if the building owe authorized $ such permit is not commenced within 180 ysfro7$ :... STRUCTURES OVER 3 STORIES IN HEIGHT
'ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON- abandoned at any time Jar the work in commenced to i per of'I80'd
- ' - STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND - . -. -. ... APPROVE'I BY.
KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND APPLICANT'S SIGNATURE WNE -'-- CO-4TRAGi 4J
.'EXPENSES WHICH MAY IN ANY
GRANTING OF THIS PERMIT.
WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE j It
-
-
oJ
so
U-
>.
so
0 0.
E so I-
-D
0 C!,
15 so 0
0. 0.
B-,
0
0 a, 0. in C
rICLD INSPECTION RECOflD -
REQUIRED SPECIAL INSPECTIONS INSPECTORS NOTES
INSPECTION. REO. IF
CHEC
KED INSPECTOR'S
gVAL s DATE ox owAw&,gQp
SOILS COMPLIANCE n .ae&'n dd1Thfr i(1 A44'C/4€..-. PRIORTO .
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
FIELD WELDING
HIGH STRENGTH
BOLTS
SPECIAL MASONRY
PILES' CAISSONS
1
INSPECTION TYPE DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL
MASONRY #4d/Z fld
GUNITE OR GROUT
FLOOR & CEILING SUB FRAME
SHEATHING
FRAME
EXTERIOR LATH
'
INTERIOR LATH & DRYWALL
PLUMBING
--
SEWER AND BL/CO 7ç1 3 I?576 PLUMBING UNDERGROUND /
PLUMBING TOP OUT
TUB AND SHOWER PAN
GAS TEST 10
- ELECTRICAL
TEMPORARY POWER
ELECTRIC UNDERGROUND
ROUGH ELECTRIC
ELECTRIC SERVICE
BONDING
G. F. I. - SMOKE DETECTOR
MECHANICAL
DUCT & PLEM.. REF. PIPING
HEAT - AIR COND. - SOLAR SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION IVHEN ALL APPROPRIATE
ITEMS ABOVE HAVE BEEN APPROVED.
I hereby affirm that i am licensed under
provisions of Chapter 9 (commencing with
Section 7000) of Division ,3 of the Business
and Professions Code, and my license is In
full force and effect.
Luc. No. __Class
I hereby affirm that I am exempt from the Contrac-tors License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which re-quires a permit to snnctruvi. after, improve dnmolich, or repair any structure, prior to its issuance also requires the ap-
plicant for such permit to file a signed statement that he is licensed pursuant to the provisians of the Contractors
License Law (Chapter 9 commencing with Section 7000 at Division 301 the Business and Professions Code) or that is ex-
the refrom and the basis for the alleged exemption. Any violation 01 Section 7031.5 by an applicant for a permit sub-
iecis the applicant to a civil penalty at net more than live hun-
dred dollars ($500).
O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the struc-ture is not ielcndcd or nllcrcd for 301c (Soc. 7044, Business and Professions Code: The Contractor's License Law doesnot apply to an owner of property who builds or improves thereon and who does such work himself or through his own
emplayees, provided that such improvements are not intend-ed or offered for safe, if, however. the building or improve-
ment is sold within one year at completion, the owner-builder will have the burden of proving that he did not build or ins-
prove for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner 01 property who builds or Im-proves thereon, and who contracts for each projects with a contractor(s) license pursuant to the Contractor's License Law).
As a homeowner lam improving my home, and the fallow-ing conditions exist: The work is being performed prior to sole. i have lived in my home for twelve months prior to completion 01 this work, i have not claimed this exemption daring the last three years.
O lam exempt under Sec. . B& P.C. for this reason
80 w
—a
lxi Z
0
Z 0
0—
z 'Ii 0.
0 U
O i hereby affirm that I have a certificate of consent to self-insure, or a certificate of Workers'
Compensation insurance, or a certified copy thereof
(Sec. 3800. Labor Code).
POLICY NO. _ --
COMPANY
C Copy is filed with the city.
C Certified copy is hereby furnished
CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE
(Thus section need not be completed it the permit is for one hundred dofiars ($100) or less)
0 i certify that in the performance of the work for
which this permit is issued, i shall not employ any
person in any manner so as to become subject to the Workers' Compensation Laws of California
NOTICE TO APPLICANT: if, after makin3 this Cent I ucate of Exemption, you should become subject to
the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked
01
r -o I hereby affirm that there is a construction
lending agency for the performance 01 the work lot
a which this permit is issued (Sec 3097, Civil Code)
Lender's Name
,sAdclresS
her DAlI DAILY SCSI AIIIV B DDCCC UADfl APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
'CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT
1200 Elm, Carlsbad, California 92008.1989 (619) 438.5525
JOB ADDRESS . . AV. ST. DATE OF APPLICATION
d Z2eFO PZ4 2ijL,4 7%á/3 I -
OWNER'S NAME OWNER'S PHONE CONTRACTOR .
" ,' p,e/sgs 4'J4
BUSINESS LICENSE #
CONTRACTORS PHONE N
VALUATION PERMIT NUMBER
5/7 ZONE
OWNCfl3 MAILING ADOflCCG
104i'frA c C141
kONTRAr,TOR'SACSDRFSS LICENSE NO. PLAN I.D. # BLDG USE CODE
LOT BLOCK SUBDIVISION ASSESSOR PARCEL NO, DESIGNER
DESCRIPTION OF WORK
LICENSE # STANDARD PLAN # BUILDING SO. FOOTAGE
- - DESIGNER'S ADDRESS DESIGNER'S.PHONE
Not Valid Unless Machine Certified
-
: F/P FLRELEV.
YO NO
STO
NO
RIES
OCCGP EDU
CENSUS TRACT GP LAND USE PARKING SPACE RES UNITS GRADING PERMIT ISSUED
Y 0 N 0
REDEVELOPMENT
AREA
V 0 NO
TYPE
CONST
0CC LOAD FIRE SPR
YO NO
QTY. PLUMBING PERMIT. ISSUE t'-y !..... QTY. MECHANICAL PERMIT - ISSUE 3 SUMMARY/ACCOUNT NUMBER
- EACH FIXTURE TRAP
r'
, - INSTALL FURN, DUCTS UP TO 100,000 BTU BUILDING PERMIT 01-00-00-8220
EACH BUILDING SEWER . OVER 100.000 BTU . SIGN PERMIT 01-00-00-8221
EACH WATER HEATER AND/OR VENT . - BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 01-00-00-8806
EACH GAS SYSTEM I TO 4 OUTLETS . BOILER/COMPRESSOR 3-15 HP TOTAL PLUMBING 01-00-00-8222
EACH GAS SYSTEMS OR MORE - , METAL FIREPLACE , ELECTRICAL 01-00-00-8223
-
EACH INSTAL.. ALTER, REPAIR WATER PIPE . -
VENT FAN SINGLE DUCT . MECHANICAL 01-00-00-8224
EACH VACUUM BREAKER . MECH EXHAUST - HOOD/DUCTS . MOBILEHOME 01-00-00-8225
WATER SOETNER - . -
RELOCATION OF EA FURNACE/HEATER . MOBILEHOME PARK INSP
EACH ROOF DRAIN (INSIDE)
- - - - - - SOLAR 01-00-00'8226
TOTAL PLUMBING .
TOTAL MECHANICAL
-
STRONG MOTION 80-92-33-0519
FIRE SPRINKLERS 01-00-00-8227
QTY. ELECTRICAL PERMIT - ISSUE CITY. SOLAR -ISSUE
PUBLIC FACILITIES FEE 32-00-00-8923
BRIDGE FEE
NEW CONST EA AMP/SWTIBKR COLLECTORS -- SCHOOL FEE - DISTRICT
-
1 PH 3 PH , STORAGE TANKS - Carlsbad - 80-92-21-0519
-
EXIST BLDG EA AMP/SWT/BKR
-
ROCK STORAGE - Encinitas 80-92-22-0519
-
1 PH 3 PH , - PUMP . - San Dieguito 80-92-29
REMODEL/ALTER PER CIRCUIT PLAN CHECK FEE - anMarCos 80-92-24-0519
TEMPPOtE
- TOTAL ELECTRICAL z/"O'
OVER 200 AMPS
TEMP OCCUPANCY I30DAYS)
- TOTAL SOLAR TOTAL FEES PAYABLE
- I H VE CAREFULLY,EXAMINEO THE COMPLETED "APPLICATION AND PERMIT" ANôwDO HEREY - Ekpfration.Eery Permiti4uedbytheBuifdingOfIiciiIert?ueprovlaorsothi AMOR PERMIT IS A REDOR XCAVATIONSOVEA
.CE TIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code Shall expire by' lImItatIon and become null andoid It the b'hitiding or work 0 DEEP AND DEMOLITION OR CONSTRUCTION OF
DEcLARA1IONS ARE TRUE AND CORRECT AND.
l URTHER CERTIFY AND AGEE IF A PERMIT IS permit. or iauthorized 1 :unr TRUc1IRES OVER 3 STORIES IN HEIGHT
ISSUED: TO COMPL!Y WITH ALL CITY, COUNTY AND STATE-LAWS GOVERNING BUILDING CON- abandoned at any time slier the work In commenced fo
such-permit is not commenced within 180
r a'/od of 180da - --
STRJCTION=, WHEThER SPECIFIED (IEREIN.OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND JJf VED BY DATE KE,EP HAbMLSS THE OITY,OF CABLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND APPL5 S SIGP.URE * OWNER CONTRA .
EXPENSES WHICH.MANY IN ANY
GRANTIIG _OF ThIS PERMIT__
WAY ACCRUE AGAINSTSAIDCITYINCONSEQUENCEOF THE BY PHONE0 I
INSPECTION TYPE DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL
MASONRY
GUNITE OR GROUT
FLOOR & CEILING SUB FRAME
SHEATHING
FRAME
EXTERIOR LATH INSULATION
INTERIOR LATH & DRYWALL
PLUMBING
SEWER AND BL/CO
PLUMBING UNDERGROUND
PLUMBING TOP OUT
TUB AND SHOWER PAN
GAS TEST
ELECTRICAL
TEMPORARY POWER
ELECTRIC UNDERGROUND
ROUGH ELECTRIC
ELECTRIC SERVICE
BONDING
G. F. I. - SMOKE DETECTOR
MECHANICAL
DUCT & PLEM.. REF. PIPING
HEAT - AIR COND. - SOLAR SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HAVE BEEN APPROVED.
PLUMBING
ELECTRICAL
MECHANICAL
GAS
BUILDING
SPECIAL CONDITIONS
CERT OF OCCUPANCY ISSUED
FIELD INSPECTION RECORD . .
REQUIRED SPECIAL INSPECTIONS INSPECTORS NOTES
REQ. IF INSPECTORS - INSPECTION DATE CHECKED APPROVAL
SOILS COMPLIANCE
PRIOR TO
I-UuNDArIUN INSI'
STRUCTuHML COtGRI...
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED CONCRETE
FIELD WELDING
HIGH STRENGTH
BOLTS
SPECIAL MASONRY
PILES. CAISSONS
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 122
SAN DIEGO, CA 92123
(714) 60-1468
83-si
(q
JP 1PU(
:
APPLICANT COPY
___ CITY COPY
PLAN CHECKER COPY
f
Citp of CarIbab
A-rTc4 ir:
&:L. P'POLT Fon...
Sp#i-Ms1 V,zL4-G
JURISDICTION:C.A.LS DATE_ 3/1 16 ________
PROJECT ADDRESS: 2.2.80 PLR Z.0 EL.
TO: EThI.AJ A At A)
515 _!1- Gesimaves
0L4iJA 9c..1
PLAN CORRECTION SHEET
SINGLE FAMILY AND DUPLEX DWELLINGS
Plan Check No._______________________________
Date plans received by jurisdiction______________
Date plans received by plan checker______________
Date initial plan check completed 3/I/3bY CM
FOREWORD: PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code. Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
based on laws and ordinances enforced by the
Planning Department, Engineering Department
or other departments.
The items circled below need clarification,
modification or change. All circled items have
to be satisfied before the plans will be in
conformance with the cited codes and regulations.
Per Sec. 303 (c), 1979 Uniform Building Code,
the approval of the plans does not permit the
violation of any state, county or city law.
A. PLANS
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have
been returned to you by the jurisdiction,
to:
2. To facilitate rechecking, please identify,
next to each circled item, the sheet of
the plans upon which each correction on
this sheet has been made and return this
check sheet with the revised plans.
Indicate on plans the name of the legal
cwner and name of person responsible for
the preparation of the plans. Sec. 302(b)
Submit fully dimensioned plot plan drawn
to scale showing location size, and use
of all existing and proposed structures
on the lot. Identify property lines and
show lot dimensions and all easements.
Show location of all cut or fill slopes
and approximate finish floor elevations
for all structures and show elevations at
all corners. Sec. 302(b)7.
Indicate distance from center-line of Street
or alley to property line and distance from
curb to property line. Sec. 302(b)7
Plans, specifications and calculations shall
be signed by a California State Licensed
engineer or architect. (California
Business and Professions Code)
FIRE PROTECTION
Walls closer than 3 feet to property lines
shall be one-hour fire-rated construction,
have no openings, and shall have 30 inch
parapets when the building floor area exceeds
1,000 square feet on any floor. (Table 5-A
Sec. 1709(a)
Projections, including eaves, may not extend
more than 12 inches into the 3 foot setback
from the property line. Sec. 1710 and
Sec. 504(b)
Projections, including eaves, shall be one-
hour fire-resistive construction, heavy
timber or of non-combustible material if
they project into the 3 setback area from
the property line. Sec. 1710
Show location of permanently wired smoke
detector. Sec. 1210
ROOM SIZES, LIGHT, VENTILATIONS AND GLAZING
One room must contain a minimum of 150 square
feet of superficial floor area. Sec. 1207(b)
Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor
area. Sec. 1207(b)
Window area must be at least 1/10 of the
floor area and a minimum of 10 square feet
per Sec. 1207(a). Appears to be deficient
in
Openable window area must be 1/20 of the
floor area and a minimum of S square feet.
In bathrooms, laundry rooms and similar
rooms. Minimum is 1.5 sq.ft. (Sec.1205(a)
One-half of all required window area must be openable in
$ Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required windows
are not provided. Sec. 1205(a)
No habitable room, other than a kitchen,
shall be less than 7'0" in any dimension.
Sec. 1207(c)
Show that ceiling height for habitable
rooms is a minimum of 716". Sec. 1207(a)
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a
minimum of 7'0". Sec. 1207(a)
Provide 30" clear width for water closet
compartments and 24" clearance in front
of water closet. Sec. 1711(b)
No cooking room shall be used for sleeping
purposes, unless complying as an efficiency
living unit. Sec. 1208
.400'specizy safety glazing for glazing in hazardous
locations such as glass doors, glazing
adjacent to such doors and glazing adjacent
to walking surfaces. Sec. 5406
Glazing in shower and tub enclosures
(including windows) shall be tempered,
laminated or approved plastic.
Sec. 1711 (f)(g)
)"S1eeping rooms shall have a window or
' exterior door for emergency exit. Sill
height shall net exceed 44" above the floor.
The window must have an openable area of
at least 5.7 square feet with the minimum
openable width 20" and the minimum openable
height 24". Sec. 1204
)V(Eaves and cornices may not project into
a required yard more than 2 inches for each
foot of yard width if required windows
open.into the yard. Sec. 1206(d)
A mezzanine is an intermediate floor and
may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below, and the mezzanine floor must have
a clear height of 7 feet, above and below,and
must have 65% of the long side open to the
room below.
The loft you show does not comply as a
mezzanine floor and is, by Building Code
definition, a story_____________________
D. EXITS, STAIRWAYS, AND RAILINGS
Floors above the second story shall have
not less than 2 exits. Sec. 3302(a)
Required exit doorways shall be not less
than 36" in width and not less than 61 -8-
in height, and shall be capable of opening
at least 90 degrees. Sec. 3303(e)
Provide 36" high protective railing for
porches, balconies, and open sides of landings.
Maximum opening between railings shall be
less than 91. Sec. 1716
Show how guardrail connection details are
adequate to support 20 pounds per lineal
foot at a right angle to the top rail.
Table 23-B
Provide stairway-.n 1---ng details.
Sec. 3305(b) & (c)
Maximum rise 8" and minimum run is 9".
Minimum head room is 6-6".
Minimum width is 30".
Handrails shall satisfy the following:
Provide handrail for stairways over 30"
high when serving a single dwelling.
Title 24, Sec. T25-22(b)
Handrail shall be 30" to 34" above the
nosing of treads. Sac. 3305(j)
Handrail projecting from a wall shall
have a space not less than 1 1/2" between
the wall and the handrail. The hand grip portion of handrail shall
be not less than 1 1/4" nor more than
2" in cross-sectional .dimension.
Sec. 3305(j) (see attached)
)st'(Every stairway landing shall have a dimension,
measured in the direction of travel, at
Nast equal to the stairway width.
Sec. 3305(g)
A door may open over a stairway landing
provided the door, in any position, does
not reduce the clear area of the landing,
in the direction of stairway travel, to
less than one-half the required width of
the stairway. Sec. 3305(g)
A door may open inward at the top step of
a stairway provided the top step is not
more than 7 1/2"-lower than the floor level.
Sec. 3303(i)2
Provide details of winding stairway.
Minimum tread is 6 inches at any paint
and minimum 9 inches at a point 12 inches
from the side of the stairway.
Maximum rise is 9 inches.
Minimum width is 30 inches. Sec. 3305(d)
(see attached)
p(Provide spiral stairway details:
Minimum run is 7 1/2 inches at a point
from where the tread is the narrowest.
Maximum rise is 9 1/2 inches.
Minimum headroom is 6 feet 6 inches.
Sec. 3305(f)
(see attached)
Spiral stairways may not be used for required
exits when the area served is greater than
400 sq. ft. Sec. 3305(f)
Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail. Sec. 3305(f)
Provide I.C.B.O. Reasearch Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabrication plans. Sec. 306(a)43
and Sec. 306(f)
buildings over 2 stories in height, provide
3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
way. An exit balcony with 2 separated
stairways is exempt. Sec. 3305
0600.0'Exterior stairways shall not project into
the 3 foot setback from the property lines.
Sec. 3305(n)
The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Sec. 3305(m)
Minimum construction specifications shall
be made a part of the approved plans.
(See attached)
E. ROOFING
J("Specify roof pitch.
lie Roof pitch is not adequate for roof type
specified. Specify minimum pitch of__________
Specify roof material and application.
Specify I.C.S.O. approval number for roof
materials not covered in UBC.
,04 Specify roof slope for drainage or design
to support accumulated water. Sec. 3207(a)
J.!'' Show roof drains and overflows. Sec. 3207(a)
Provide skylight details to show compliance
with Sections 3401 and 5207 or provide ICBO
approval number.
Provide plastic roof panel details to show
compliance with Section 5206 or provide
XCBO number.
Show attic ventilation. Minimum vent area
is 1/150 of attic area or 1/300 of attic
area if at least 501 of the required, vent
is at least 3 feat above ceiling joists.
Sec. 3205(c)
Show I 3/8" solid core self-closing door
for openings between garage and dwelling.
Sec. 503(6)
)4. Garages are not permitted to open into
a room used for sleeping purposes. Sec. 1104
Openings between carport and residence
require self-closing doors and stationary
windows. Sec. 1214
Show garage framing section. size of header
over garage opening, lateral cross bracing
at plate line and method of bracing garage
front. Chapter 23
NOTE: Minimum plywood diaphragm ratio is
3 1/2 to 1 or 2'8". Table 24-I
Doors between dwellings and attached garages
may swing in either direction provided
the difference in floor elevation between
the dwelling and garage does not exceed
7 1/2 inches and provided the door is not
used as the primary means of egress from
the building.
If the difference in floor elevation exceeds
7 1/2 inches, or if the door is used as
the primary means of egress from the building,
additional steps or landing must be provided
in accordance with stairway requirements,
and the door must not swing over the depressed
level. (see 3303(i)2 and 3305 (g).
Provide 13" raised platforms for any FAU,
water heater, or any other device which
may generate a flame or spark.
000
Note that continuous fire wall protection
shall be installed behind raised platform(s)
prior to framing platform. -
H. MASONRY
Provide fireplace construction details or
note construction to be per attached fireplace
standard drawing. Sec. 3707
H. FOUNDATION REQUIREMENTS
:Note on plans thatA soils engineer shall
- evaluate any unanticipated uncompacted fill
or expansive soil or other soil problems
disclosed durinc construction". Sec.306(a)12.
Show veneer support and connections comply
with Sec. 3002, 4.5,6, and Sec. 2516(a)
regarding ties and #9 wire in horizontal
joints or note construction to be perattached
sheets 30-1 or 30-2.
Show height and construction details of
all masonry walls. Chapter 24
)1"Note that cleanout openings shall beprovided
at the bottom of all cells to be grout filled
over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Sec. 2415
Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds
per lineal foot or the actual design load,
whichever is greater. Sec. 2310 4: Provide material specifications for mortar,
grout, masonry and reinforcing steel.
Sec. 2403
Show how masonry house walls retaining earth
are to be waterproofed. Provide detail.
Note that special inspection of the masonry
will be required for
C. GARAGE AND CARPORTS
j.e(Garage requires one-hour fire protection
on the garage side of walls and ceiling
common to the dwelling. Table 5-B Sec.503(b)
elements supporting floor above garage
to have one-hour fire-resistive protection
on the garage side. Sec. 503. Beams and
posts, riot within the wall or ceiling con-
struction, must comply with UBC, Table 43-A,
or be minimum 6" dimension beam and minimum
8" by 8 post.
4 SE€. Te. Tcap SoIL. REPDXT, LOT 47 At, ?Uo1 I&)cLoW'S
G Submit soils classification determination
by a licensed engineer or architect based
on observation, tests, borings, or excavations,
and containing comments on the degree of
expansiveness, compressibility and bearing
value. Sec. 2905
Note on the plan the soils classification.
whether or not the soil is expansive, and
note the allowable bearing value. Sec. 2905
The foundation plan does not comply with
the soil report recommendation for this
project____________________________________
0the
Provide notes on the foundation plan listing
soils report recommendations for foundations.
slab and building pad preparation.
Note on the foundation plan that "Prior
to the Contractor requesting a Building
Department foundation inspection, the
soils engineer shall advise the Building
Official in writing that:
the building pad was prepared in accor-
dance with the soils report:
the utility trenches have been properly
backfilled and compacted, and:
the foundation excavations, forming
and reinforcement comply with the soils
report and approved plan."
Provide spread footings for concentrated
loads designed for 1,000 PSF soil bearing
or per bearing value as determined by
an engineer or architect. Chapter 29
Show height of all foundation walls. Chapter 23
Show height of retained earth on all foundation
walls. Chapter 23
Show distance of foundation to edge of
cut or fill slopes and show steepness and
heights of cuts and fills. Chapter 29
Note on plans that wood shall be 6" above
4,finish grade. Sec. 2417(c) 7.
Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Sec. 2905(f)
131 Dimension foundation per Table 29A.
&ou D PT OF I#3Te,RJOR.,. Prc
TABLE NO. 29.A—FOUNDATIONS FOR STUD BEARING
WALLS—MINIMUM REQUIREMENTS
DEPTH OF
FOUNDATION WIDTH THICKNESS BELOW
NUMBER THICKNESS OF OF OF NATURAL
OF FOUNDATION WALL FOOTING FOOTING SURFACE
STORIES (Inches) (Inches) (Inches) OF CROUND
AND FINISH
CONCRETE UNIT MASONRY
DRABS (Inches)
1 6 6 12 6 12
2 8 8 15 7 is
3 10 10 18 8 24
NOTES:
Where unusual conditious or frost conditions are found, footings and
foundations shall be as required in Section 2907(a).
The ground under the floor may be excavated to the elevation of the
top of the footing.
Show foundation sills to be pressure treated,
or equal. Sec. 2517(c) 3.
Show foundation bolt size and spacing.
Sec. 2907(e)
3.?4 Specify size, ICB0 number and manufacturer
of power driven pins. Show edge and end
distance and spacing. Sec. 306(f)
Show size, inthedment and location of hold
down anchors on foundation plan. Sec. 2312(f)
Note on plan that hold down anchors must
be tied in place prior to foundation inspection.
Sec. 2312(f)
Show adequate footings under all shear
walls. Sec. 2311(e)
Show stepped footings for slopes steeper
than 1:10. Sec. 2907(c)
Show minimum 18" clearance from grade to
bottom of floor joists and minimum 12"
clearance to bottom of girders. Sec. 2517
Show pier size, spacing and depth into
undisturbed soil. Table 29-A
Aotf Show minimum under floor access of 18"x 24".
Sec. 2517
Show minimum under floor ventilation equal
to 1 1/2 sq. ft. for each 25 lineal feet
of exterior foundation with openings as
close to corners as practicable to provide
cross ventilation on at least two approximate-
ly opposite sides. Sec. 2517
I. FRAMING
JAIr Show all joists, rafters, beams, and posts
2" to 4" thick to be No. 2 Grade Douglas
Fir-Larch or better. All posts and beams
5" and thicker shall be No. I Grade Douglas
Fir-.arch or better. (Table 25-A-1)
1.,è'(Show wall bracing. Every exterior wood
stud wall and main cross partition shall
be braced at each end and at least every
25 feet of length with 1x4 diagonal
let-in brace or equivalent. Sec. 2518(g)5
Note cross bridging or blocking. Floor
joists and rafters more than 12" in depth
and spanning more than 8 feet shall be
supported laterally by bridging at intervals
not exceeding 8 feet. Sec. 2506(g)
Show blocking at ends and at supports
of floor joists, and for rafters at exterior
walls. Sec. 2506(g)
164 Show solid blocking at ridge line and
at exterior walls on trussed roofs.
Sec. 2506(g) A2.J4
165 Show double joists. Floor joists shall
be doubled under bearing partitions running
par lid with the oist . Sec. 2518(d) 5
spaced not mo than 4 feet on center re
where rafters and ceiling joists are not
parallel. Sec. 2518(h)
Show rafter purlin braces to be not less
than 45 degrees to the horizontal. Sec. 2518(h)
Show 1/2" minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading
will be as designed.)
Show double top plate with minimum 48"
lap splice. Sec. 2518(9)4
Show nailing will be in compliance with
Table 25-P.
Provide fire stops between stories, between
top story and roof space, at ceilings
and floor levels in interior and exterior
walls, in mansard roof or eyebrow so no
concealed or furred space is greater than
10' horizontally or vertically, between
stair stringers at top and bottom and
between studs along and in line with
stair run adjoining stud walls and partitions,
at perimeter of sliding door pockets,
between chimney and wood frame using metal
or incombustibles for the fire stop and
at other places that could afford passage
of flame. Sec. 2517(f)
Show stud size and spacing. Maximum allow-
able stud heights: 2"x4"8 16" is 14';
3"x4&2"X6"@ 16"o.c. is 20'. Sec. 2518(g)2
Note an A.I.T.C. Certificate of Compliance
for glued laminated wood members shall
be given to the Building Inspector prior
to erection. Sec. 306(f)
Detail all post to beam and post to footing
connections. See. 2517(c) 4
)?'S. Specify nail size and spacing for all
shear walls, floor and roof than
Indicate required blocking. Maintain
maximum diaphragm dimension ratios.
(Tables I,J,K).
A4. Show 3"x4" or 2"x6" studh in first story
of three story building. Sec. 2518(f)
177 Provide truss details and truss calculations.
)r?f. Provide roof framing plan. Sec. 302(a)7
J,?4 Provide framing sections through_____________
Section 302(a) 7
)4. Specify all header sizes for opening over
4' wide. Sec. 2518(g) 7 G. Provide calculations fortt.E. £tL( 4 &P.T
@ Lwvt. 9 M F4MIL.J JA
Section 302(a) 7
182 In areas subject to water splash and in
exterior locations, wood columns and posts
shall be supported by piers projecting
at least 2" above the finished grade and
shall bear on a metal base plate or treated
wood unless the columns or posts are foun-
dation grade redwood or cedar. Sec. 2517(c)4
Co;:: ALj&'cnJT Tc'
Show location of attic access with minimum
size 22° x 300. Sec. 3205
Show draft separation for attic areas
in excess of 3,000 sq.ft. Sec. 3205
Show draft separation. for space between
dropped ceilings and floor above in excess
of l,0C0 sq.ft. Sec. 2517
).8( Specify plywood grade and panel indenti-
fication index. Table 25-J
When roof pitch is less than 3:12, design
ridge as a beam. Sec. 2518 (h)
JAC Wood shear walls shall not be used to
resist horizontal forces contributed by
masonry in buildihgs over one story in
height. Sec. 2516(b)
)24'. Gypsum lath and plaster, gypsum sheathing
board and gypsum wallboard shall not be
used in vertical diaphragms to resist
forces imposed by masonry or concrete
construction. Table 47-I
JAf If cripple wall studs are less than 14",
framing shall be solid blocking. Sec.2518(g)6
Cripple wall studs exceeding 4 feet in
height shall be 3 inch by 4 inch or 2
inches by 6 inches when supporting 2 stories.
Sec. 2518(g)6
Show plywood sheathing over exposed eaves,
or other weather exposed areas, is exterior
grade. Sec. 2517(g) 3
Show a weep screed at the foundation plate
line on all exterior stud walls to be
stuccoed. Sec. 4706(e)
loe Provide an approved waterproof building
paper under wood siding. Sec. 1701(a)
195 Specify an approved flashing for exterior 3 openings and parapet walls. Sec. 3208
.,14(. Show corridor width to be minimum 36".
Sec. 3304(b)
Specify truss layout for 30" x 30" attic
access.
e4r Ridges, hips, and valleys shall be at
least one size larger than supported
rafters. Sec. 2518(h) 3
Alf 090' Provide metal straps. across ridge beam
and rafters.
J. t4ECRANICPZ.
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code.
Show the size, location and type of all
heating and cooling appliances or systems.
3,9.r Show source of combustion air for furnace
will comply with Chaper 6, U.M.C.
Every dwelling unit shall be provided with
heating facilities capable of maintain-
ing a room temperature of 700 P. at 3
feet above the floor in all habitable
rooms. Show basis for compliance. UBC.
Sec. 1211
Show minimum 30" deep unobstructed working
space in front of furnace.
204 Note on plans,c1earances to be per manufac-
t urerss listing. Sec. 704 UMC
Furnace shall not be installed under any
stairway. Sec. 704 UMC
Pir Furnace shall not be installed in any
bedroom, bathroom, closet, or in confined
space with access only through such room,
unless specified as direct vent appliance,
enclosed furnace or electric heating appliance.
Sec. 704 UMC
Show ICBO approval for prefab fireplace
and provide approved installation instructions
at job site.
Show access to the attic or under floor
furnace to be minimum 30 inches by 30
inches. Sec. 708 & 709 UMC
Note that passageway to the attic furnace
shall be unobstructed and have continuous
solid flooring not less than 24 inches
wide. Sec 708 UMC
Show permanent electrical outlet and
lighting fixture controlled by a switch
for the attic furnace. Sec. 708 UMC
Show details to comply with Section 109
for furnace under the floor, Section 708
for attic furnace, or Section 710 for
roof or outside furnace.
Note on plan, gas vents and non-combustible
piping passing through three floors or
less shall be effectively draft stopped
at each floor oè ceiling. UBC Sec. 1706(a)6
K. ELECTRICAL (National Electrical Code)
All wiring shall comply with the National Electrical
Code.
Note on the plan the amperage of electrical
service.
If the electrical installation is more
than 200 amperes, show panel location
and provide a single line diagram and
load calculations including:
Wiring method employed.
Sizes of all conductors, switches,
circuit breakers, fuses, and conduits.
C. Approximate length of service feeders.
Provide plot plan showing services,
all panel locations, circuit arrangement
and load distribution on panel busses.
Provide typical panel schedule(s).
Ø.2. Dwellings require minimum 100 amp service.
Show location of all electrical receptacles.
Electrical receptacle locations and/or
spacing is not adequate in
At least one receptacle shall be installed
outdoors, in basements and attached garages,
other than laundry outlets. Art. 210-25(b)
227 Show minimum dwelling lighting (NEC
Art. 210-26(a) and GFIS in garage, baths
and outdoors. NEC Art. 210-8(a).
228 Note "UFER" ground to be provided (NEC).
Art. 250-81
L. PLUMBING (Uniform Plumbing Code)
All plumbing shall comply with the Uniform
Plumbing Code.
Show water heater size, type and
location on plans.
Show method of providing combustion air
to fuel burning water heater. Sec. 1307
Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. Sec. 1309
Provide adequate barrier to protect water
heater from vehicle damage. Sec. 1310
Show 7 and P valve on water heater and
show route of discharge line to exterior
Sec. 1007(e)
Provide dryer vent to outside. UMC
Sec. 1903
Note on the plan that hose bibbs and lawn
sprinkler systems shall have approved
backf low prevention devices. Sec. 1003
Shower stall shall accomodate a 30"circle
and have a minimum floor area of 900 sq.in.
UPC 909(d)
N. NOISE INSULATION (DUPLEXES)
Show details of duplex common (party) walls
and floor/ceiling assemblies to achieve
a Sound Transmission Class (STC) rating
in walls of 50 decibles and an Impact
Insulation Class (IIC) rating on floor/
cei1in9 of 50 decibles. Title 25
f. Show how penetration of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating,
or exhaust ducts shall be sealed, lined.
or insulated to maintain required sound
transmission rating. Title 25
Provide insulation in walls and ceiling
to achieve STC of 50 between garage and
living area if garage use is not controlled
by resident title 25.
N. ENERGY CONSERVATION
All additions to existing residential
buildings must comply with Title 24
energy regulations. Additions exceeding
301 of the existing building requires the
existing and addition to have R-19 ceiling
insulation if the existing ceiling area
is accessible for insulation installation
(720-1401(c)
Specify the insulation R values for walls.
roof and ceiling. (R-ll for walls: R-19
for ceilings, or provide details and analysis
for alternate design. 720-1403 Table A a 23.
Specify the gross floor area or heated
portions of the dwelling, and the area
of glazed openings on the plan. (720-1430)
.X4. Provide an analysis justifying increasing
the single glazed area beyond 16% of the
gross f1or area. Show method to reduce
heat loss to that which would occur with
basic glazing. (720-1402,def.)
Provide energy analysis to show that the
bonnet capacity of the gas central furnace
does not exceed the building design heat
loss by more than 30%. (Exceptions:
48,000 STU Hr. output furnace. See also
.,,,..California Efficiency Adjustment.) 724-1404
Note on plan that all tranverse ducts,
plenums, and fitting joints of HVAC system
shall be sealed with pressure sensitive
tape or mastic to prevent air loss. 720-1404
Note o plan that insulation of ducts shall
conform to UMC Section 1005. (720-1404)
Note on plan that all doors and windows
to the exterior or to unconditioned areas
shall be fully weather striped per ANSI
Standard. (720-1403).
279 Note on plan that back draft dampers are
required on all fan systems exhausting
air from the building. 720-1403
Electrical resistance space heating shall
not be used. unless:
601 of heating/cooling is supplied
by a nondepletable source.
supplements a heat pump system.
C. less than 101 of total heating system.
d. life cycle cost analysis justifies.
720-1404
281 Note on plan that all heating and cooling
equipment efficiencies shall conform to
Title 20-Chapter 2, Subchapter 4, Article 4.
(75% for forced air furnaces).
282. Note on plan that no natural gas, central
heating plant may be installed without
an Intermittent Ignition Device. 720-1405
;Of. Electric resistance water heating is not
permitted unless verfied as cost effective
by a life cycle cost analysis. 720-1406
3.84:' Outdoor pools with fossil fuel heaters
require pool covers as well as other energy
saving devices such as time clocks, etc.
720-1406
0. MISCELLANEOUS
Show a minimum 2 air space and flashing
between planter and building walls.
Sec. 2517(e)
Specify material to be used under the
shower tile. Sec. 1707(a)
Specify lath and plaster to comply with
Chapter 47, UBC.
Two 3/4" copper pipes must be installed
from water heater location to convenient
location of future solar panels (City Ord.)
Provide sleeves (roof jacks) in roof for
two future 3/4" copper pipes to cunvenient
location of future solar panels (City Ord.)
0
Note that solar water piping is to be insulated
in areas that are not heated or cooled.
(City Ord.)
307 See attachment for roofing requirements.
NOTE:
The plans were reviewed based on the information shown on
the plans. If the plans are in error, or changed during
construction, the permittee shall contact the Building
Department for review and prior approval before proceeding
with the work:
0 Building plans are substantially correct
and complete.
By:
Date:
13 Building plans would be substantially correct
and complete if minor corrections are made
at counter.
By:
Date:
Building plans require major corrections and
complete plan recheck, by plan check
engineer, is required.
By:Ci&UJL 4LU
Date:_____________________
If you have any questions regarding this plan check, please
—at SO't4(t,.
We would also be pleased to meet with you, at no charge, if
additional assistance is needed.
Ordinary roof coverings may be used only on buildings of
Group M occupancies. (City Ord. 8093)
Fire-retardant roofing is required on all residential
dwellings per City Ord. 8093-
1979 EDITION UNIFORM BUILDING CODE 3203
(e) Fire-retardant Root Coverings. A lire-retardant roof covering shall
he any one of uhe following roofings:
.Any Class A or B built-up roofing assembly.
Any mineral aggregate surfaced built-up roof for application to
roots having a slope not more than 3 inches to 12 inches applied as
specified in Section 3203 (d) I consisting of not less than the
lollowing:
Roof I)eck
Solid surface on noncombustible materials or minimum of ½-inch
plywood or 1-inch nominal boards or other material approved by
the building official.
Base Sheet and Plies
Four layers of Type IS perforated organic fiber felt, or
Three layers of Type IS organic or inorganic fiber felt, and
Surfacing Material
4(K) pounds per roofing square of gravel, crushed rock, ceramic or
approved similar surfacing material, or
3(K) pounds per roofing square of crushed slag.
ISec U.ILC. Standard No. 32-5 for mineral roofing aggregate weigh-
ing less than 60 pounds per cubic fool.)
Any built-up roof for application 10 roofs having a slope not less
than inch to 12 inches applied as specifiedin Section 3203 (d) I,
consisting of not less than the following:
Rout Deck
Solid surface on noncombustible materials or minimum of ti-inch
plywood or I-inch nominal boards or other material approved by
the building official.
Base Sheet and Plies
Two layers of Type IS organic fiber felt, or
One layer of 14-pound glass fiber felt base sheet, or combination
sheet, or
One layer of Type 30 organic fiber felt, or
One layer of Type 45 asbestos fiber felt base sheet, and
Cap Sheets
One layer of 90-pound mineral surfaced organic fiber felt cap sheet
(requires not less than two layers of organic fiber felt), or
Two layers of 55-pound mineral surfaced organic fiber felt split
sheet, or
One layer 0180-pound mineral surfaced.asbestos fiber felt cap sheet,
or -
One layer of 72-pound mineral surfaced glass fiber Felt tap sliecu, ni
Two layers of Type IS asbestos fiber finishing felts.
Any (lass A or B prepared roofing.
Any Class C mineral surfaced asphalt shingles laid so that there are
not less than two thicknesses at any point and the total weight per
roofing square is not less than 235 pounds.
Asbestos-cement shingles or sheets.
7: Concrete slab roof.
Metal roof covering.
Slate shingles.
Clay or concrete roof tile.
If. Any roof covering systems of ood shingles or shakes having a
Clals B rating.
ITIONAL REMARKS
S
Date: 512-/8,3
Prepared by:
C, M.
Jurisdiction (iw1.5
Bldg. Dept.
VALUATION AND PLAN CHECK FEE a Esgil
PLAN CHECK NOS_B5I
BUILDING ADDRESS _24-20 PJ1ZU!LA
APPLICANT/CONTACT bt* 'r',J PHONE NO. 461-91(.v5
BUILDING OCCUPANCY DESIGNER PHONE____________
TYPE OF CONSTRUCTION \i-1'J CONTRACTOR PHONE__________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
2979 47 t40 Vb -
(ô3 (.Q 7O
(11'\iered c!.k ISM 7 20 - 2-917 ,SO
Res. Baths (over 3) @2,200
rr
Res.Firep1aces(°' @1,760
Air _Conditioning
-
Commercial 2.80
Residential 2.40
Res. or Comm.
- Fire Sorinklers 1.50
Total Value (50 flo
Adjustment for State
Mandated handicapped
Access Regulations
Building Permit Fee $_ c'-.' -.JLl-.-J
33
Plan Check Fee $ 3 A
- x
C 0 H MEN
8/4/82
City of Carlsbad MISCELLANEOUS
1200 ELM, CARLSBAD, CA 92008 • TEL. (714) 438.5525 RECEIPT
MISCELLANEOUS FEE RECEIPT
PLAN CHECK FEEa/'—go—aa -li'o1
O VALUATION________________________
O DEMOLITION___________________________
HOUSE MOVING_________________________
El PARKS AND RECREATION FEE________________
El PUBLIC FACILITIES FEE______________________
SCHOOL FEE - DISTRICT_____________________
Carlsbad___________________________________
El Encinitas
San Diego
0 San Marcos
-
p ..
0.
TOTAL FEE
White - Applicant Yellow - File Pink - (1) Finance (2) Data Process Gold. - Assessor .
FINAL: DATE:
INTERDEPARTMENIAL INFORMATION SHE
SF CE IVE B
BIJJLDING DEPARTMENT DATE:____________ FEB 23 1983
BUILDING ADDRESS: --Zlteo ?LPSIJ..A
- —J OF
PLANNING DEPARTMEN CO' 5o%JIAG%
ZONE: /SCHOOL FEES: SAN DIEGUIT 'P SAN NoA
ENCINITAS 1110" CARLSBAD______________
UNITS REQ'D: PROVIDED:____________________
% COVERAGE ALLOWED: V - •PROVIDED:
PARKING SPACES REQ'D: PROVIDED: 1' J
BUILDING HEIGHT REQ'D: PROVIDED:
FRONT SETBACKI
ALLOWED: f,ffl\
PROVIDED: ) <
INTRUSIONS:
SIDE SETBACK
IL
/ Il,
REAR SETBACK
RE-DEVELOPMENT APPROVAL REQ'D:
LANDSCAPE & IRRIGATION PLAN COMMENTS:
ENVIRONMENTAL PROTECTION REQ:
DflIONAL COMMENTS:
ENGINEERING DEPARTMENT
R.O.W: IMPROVEMENTS: V
PUBLIC FACILITIES FEE: SEWER CONNECTION:
DRIVEWAY LOCATION(S):
GRADING PERMIT:
EASEMENTS: DRAINAGE:_____________________________
LEGAL DESCRIPTION:
ADDITIONAL COMMENTS:
*CHECK IF ENINEERING INSPECTION REQTD..ON FINAL:
OK TO ISSUE: j'WQ DATE: PWI: OK TO FINAL:
DATE:
*•** * * * * * * * * *jL* * * * * * * * * * * * * * * * * * * * * * * * k* * * * *
* IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE
FINAL INSPECTION.
I
1/ J. THOMAS WILSON i
J
I L 3
/er i• i4j 1'
-••::;74t.) e,t -- , '::?/8/Ji(
-
1. 37 ; ,;
/.
/ y ,
2 3/
?, over
= 315P $ /' = 2-o
z57 -z-7'
13
-
L.(U1) 3114 1=
= 2.37.1"'
7 4
g 3 -CO / 0 ~
-
4/ OX /f' x
._-.
.L
I
J
Jaé
831°
I * L - / -
--.-
-
- -/
/—r/
/
--
-.
r -
-_
11 i/ I
7Lt4ft 47
7. S-10 t ) 7- --a 51 21
-2z, L~D
JOHN VERNON & ASSOCIATES
1859 S. ESCONDIDO BLVD.
ESCONDIDO, CA 92025
TEL. (714) 743-8808
February 23, 1983
Messers C. Frerichs & C. Mettling
do Edward M. Eginton, Architect, Inc.
515 S. Granados Ave.
Solana Beach, Ca. 92075
Subject: Preliminary Soils Survey
Site: Lot 47, Spanish Village Unit #1, Map 7895, Carlsbad, Ca.
Gentlemen:
At your request our firm has completed ,a Preliminary Soils Survey of the
existing surficial soils at the above site. Our survey included review
of the original Tract 72-24 Grading Plan (sheet 2 of 6), a Final Report
on Compacted Fill Ground of Spanish Village Unit No. 1 (Carlsbad Tract 72-24).
by Benton Engineering, Inc., dtd. Jan. 8, 1975 (project #73-11-12-0).
A representative of our firm visually inspected the lot to note the confor-
mance of the grading to the plan, and to ascertain the soil type for
foundation design. .,
The lot has been graded in accordance with the original plan, with existing.
surface elevations varying from 7 to 20' below the original ground surface.
No evidence of fill placement was rioted.
The near surface soil is a light tan fine silty sand and is notdetrimentally
expansive. Allowable soil bearing-pressures of 1500#/sf are to be used for
design. Continuous footings should be reinforced with a minimum of 144
bar longitudin
-
and be sized in accordance with the Uniform Build Code.
C. W. DAVIS
R.C.E. 21719 .
Wk6
PROPERTY DEVELOPMENT ENGINEERS. INC.
ENGINEERING . SOILS TESTING .SURVEYING
rw"~/Owblo~ JOHN VERNON & ASSOCIATES
1859 S. ESCONDIDO BLVD.
ESCONDIDO, CA 92025
TEL. (714) 743-8808
February 23, 1983
Messers C. Frerichs & C. Mettling
do Edward M. Eginton, Architect, Inc.
515 S. Granados Ave.
Solana Beach, Ca. 92075
Subject: Preliminary Soils Survey
Site: Lot 47, Spanish Village Unit #1, Map 7895, Carlsbad, Ca.
Gentlemen:
At your request our firm has completed a Preliminary Soils Survey of the
existing surficial soils at the above site. Our survey included review
of the original Tract 72-24 Grading Plan (sheet 2 of 6), a Final Report
on Compacted Fill Ground of Spanish Village Unit No. 1 (Carlsbad Tract 72-24)
by Benton Engineering, Inc., dt1. Jan. 8, 1975 (project #73-11-12-0).
A representative of our firm visually inspected the lot to note the confor-
mance of the grading to the plan ard :c ascertain the soil type for
foundation design.
The lot has been graded in accordance with the original plan, with existing
surface elevations varying from 7 to 20' below the original ground surface.
No evidence of fill placement was noted.
The near surface soil is a light tan fine silty sand and is not detrimentally
expansive. Allowable soil bearing pressures of 1500#/sf are to be used for
design. Continuous footings should be reinforced with a minimum of 144
bar longitudin and be sized in accordance with the Uniform Build Code.
(Uo1.
C. W. DAVIS
R.C.E. 21719
PROPERTY DEVELOPMENT ENGINEERS, INC.
ENGINEERING .SOILS TESTING s SURVEYING
JOHN VERNON & ASSOCIATES
1859 S. ESCONDIDO BLVD.
ESCONDIDO, CA 92025
TEL. (714) 743-8808
February 23, 1983
Messers C(rerichs &c. MettljIII
do Edward MEginton1—M:-te , Inc.
515 S. Granados Ave.
Solana Beach, Ca. 92075
Subject: Preliminary Soils Survey
Site: Lot 47, Spanish Village Unit #1, Map 7895, Carlsbad, Ca.
Gentlemen:
At your request our firm has completed a Preliminary Soils Survey of the
existing surficial soils at the above site. Our survey included review
of the original Tract 72-24 Grading Plan (sheet 2 of 6), a Final Report
on Compacted Fill Grojind of Spanish Village Unit No. 1 (Carlsbad Tract 72-24)
by Benton Engineering; Inc., dtd. Jan. 8, 1975 (project #73-11-12-0).
A representative of our firm visually inspected the lot to note the confor-
mance of the grading to the plan and to ascertain the soil type for
foundation design.
The lot has been graded in accordance with the original plan, with existing
surface elevations varying from 7 to 20' below the original ground surface.
No evidence of fill placement was noted.
The near surface soil is a light tan fine silty sand and is not detrimentally
expansive. Allowable soil bearing pressures of 1500#/sf are to be used for
design. Continuous footings should be reinforced with a minimum of 144
bar longitudiD and be sized in accordance with the Uniform Build Code.
C. W. DAVIS
R.C.E. 21719
PROPERTY DEVELOPMENT ENGINEERS, INC.
ENGINEERING. SOILS TESTING s SURVEYING
JOHN VERNON & ASSOCIATES
1859 S. ESCONDIDO BLVD.
ESCONDIDO, CA 92025
TEL. (714) 743-8808
February 23, 1983
Messers C. Frerichs & C. Mettling
do Edward M. Eginton, Architect, Inc.
515 S. Granados Ave.
Solana Beach, Ca. 92075
Subject: Preliminary Soils Survey
Site: Lot 47, Spanish Village Unit #1, Map 7895, Carlsbad, Ca.
Gentlemen:
At your request our firm has completed a Preliminary Soils Survey of the
existing surficial soils at the above site.-Our survey included review
of the original Tract 72-24 Grading Plan (sheet 2 of 6), a Final Report
on Compacted Fill Ground of Spanish Village Unit No. 1 (Carlsbad Tract 72-24)
by Benton Engineering, Inc., dtd. Jan. 8, 1975 (project #73-11-12-D).
A representative of our firm visually
mance of the grading to the plan and
foundation design.
inspected the lot to note the confor-
to ascertain the soil type for
The lot has been graded in accordance with the original plan, with existing
surface elevations varying from 7 to 20' below the original ground surface.
No evidence of fill placement was noted.
The near surface soil is a light tan fine silty sand and is not detrimentally
expansive. Allowable soil bearing pressures of 1500#/sf are to be used for
design. Continuous footings should be reinforced with a minimum of 144
bar longitudin and be sized in accordance with the Uniform Build Code.
(a1.
C. W. DAVIS
R.C.E. .21719
Arl
PROPERTY DEVELOPMENT ENGINEERS, INC.
ENGINEERING. SOILS TESTING 'SURVEYING
Phone p"). (213) 54O-454.
LEUCADIA COUNTY WATER DISTRICT
APPLICATION FOR SEWER SERVICE I
Owner's Name Ruben J.\Kuebler
Mailing Address 210 Avenue\I, k%LLN-QA
Redondo Beach, CA 90277 '-'---
Service Address:
Tract Description: Lot 47
Assessor's Parcel No.
Type of Building Single Family No. Units 1 Connection Fee $600.00
Lateral Size: 4"
-- 6" - 8" - Saddle - Easement Connection pre-pd (200.00)
Extra Footage: $________ Extra Depth: @ $ Acam
Lateral Fee
Amount Rec'd $LfD
Ck. No/Cash Prorated Sewer
Date Service Fee
Rec'd By . Total
I Iff -4
The application must be signed by the owner (or his authorized representative) of
the property to be served. The total charges must be paid to the District at the
time the application is submitted.
If a service lateral is required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends from
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's building sewer. The applicant is responsible fo•r the construction,
at the applicant's expense, of the sewer pipeline (building sewer) from the appli-
cant's plumbing to the point in the street (or easement) where a connection is made.
to the service lateral.
The connection of the applicant's building sewer to the service lateral shall be
made by the applicant at his expense. The connection must be made in conformity
with the District's specifications, rules and regulations; and IT MUST BE INSPECTED
AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT,
THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE
TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC-
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED.
The prorated sewer service fee is based upon the date the District estimates that
service will begin and covers the balance of the fiscal year. There will be no
additional fee or refund if service actually commences on a different date. For
succeeding fiscal years, the sewer service fee will be collected on the tax roll
in the same manner as property taxes.
The undersigned hereby agrees that the above information given is correct and agrees
to the conditions as stated.
4 _ Owner% Si jnature
9/i%. V
Date Account No.
13
1200 ELM AVENUE
CARLSBAD, CALIFORNIA 92008
DEVELOPMENTAL
SERVICES
Assistant City Manager
(714) 438.5596
Building Department
(714) 438.5525
Engineering Department
(714) 438-5541
Housing & Redevelopment Department
(714) 438-5611
O Planning Department
(714) 438.5591
RESIDENTIAL VALUATION CHART EFF: 7/1/82
SFD OR DUPLEX LIVING AREA 7JO X 47.00
ATTACHED UNITS-3 OR MORE X 40.00
GARAGE AREA (W X 12.00
COVERED PORCH •X 4.50
COVERED PATIO X 4.50
BALCONIES/STAIRS
•
• X 7.50
EACH BATHROOM OVER 3 •
•
_X 2200.00 • -
EACH FIREPLACE -OVER 2 • X 1760.00
RETAINING WALLS _X 9.00
POOLS • X 19.00 •
SPAS • • • •__• • 4000.00
AIR CONDITIONING
•
• • X 2.40 -
MOBILE OR MODULAR ON S.F. LOT(½ OF BLDG. PER Ffl X
TOTAL VALUATION
f 2-42 $
PLAN CHECK FEE( 65% OF BUILDING PERMIT FEE) $___________________
ATrENTION PROPERTY OWNER:
An "owr -'builder" building permit has been applied for in your name and bearing your
signtture.
Please complete and return this information in the envelope provided at your earliest
opportunity to avoid unnecessary delay in processing and issuing your building permit.
No building permit will be issued until this verification is received.
I personally plan to provide the major labor and materials for construction of
the proposed property improvement (yes or no) )' ¶5
I .(have/1iave not) p14, signed the application for a building permit.
I have contracted with the following person (firm) to provide the proposed construction.
Name _________ Phone__________________________
Address Contractors License No._________
City_________________________
I plan to provide portions of the work, but I have hired the following person to
coordinate, supervise and provide the major work.
Name
Address Al (
City
Phone
Contractors License No.
I will provide some of th6 work but I have contracted (hired) the following persons
to provide the work indicated:
Name Adcfress Phone Type of Work
iJcrr /svo)
Signed: Property Owner
Social Security Number
Date:'
EACH SUBCONTRACTOR WILL BE INSTRUCTED TO OBTAIN A CITY OF CARLSBAD
BUSINESS LICENSE AND TO FURNISH ERTIFICATE OF WORKMAN'S COMPENSATION
TO THE CITY OF CARLSBAD.
6' Initia l s
41
1200 ELM AVENUE
CARLSBAD, CALIFORNIA 92008
TELEPHONE:
714-438-5525
City of QCartbab
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself
as the builder of the property-improvements specified. For your protection you should be
aware that as "owner-builder" you are the responsible party of record on such a permit.
Building permits are not required to be signed by the property owners unless they are
personally performing their own work. If your work is being performed by someone other
than yourself, you may protect yourself from possible liability if that person applies for
the proper permit in his or her name.
Contractors are required by law to be licensed and bonded by the State of California and
to have a business license from the City of Carlsbad.. They are also required by law to
put their license number on all permits for which they apply.
If you plan to do your own work, with the exception of various trades that you plan to
subcontract, you should be aware of the following information for your benefit and pro-
tection.. If you employ or otherwise engage any persons other than your immediate family,
and the work (including material and other costs) is $200 or more for the entire project,
and such persons are not licensed as contractors or subcontractors, then you may be an em-
ployer. If you are an employer, you must register with the state and federal gokiernment
as an employer and you are subject to several obligations including state and federal
income withholding, federal social security taxes, workers' compensation insurance, dis-
ability insurance costs, and unemployment contributions. There may be financial risks
for you if you do not carry out these obligations, and these risks are especially serious
with respect to workers' compensation insurance.
For specific information about your obligations under federal law, contact the Internal
Revenue Service (and, if you wish, the U. S. &nall Business Administration). For morei
specific information about your obligations under state law, contact the Department of
Benefit Payments and the Division of Industrial Accidents.
If the structure is intended for sale, property owners who are not licensed contractors
are allowed to perform their work personally or through their own employees, without
a licensed contractor or subcontractor, only under limited conditions.
A frequent practice of unlicensed persons professing to be contractors is to secure an
"owner-builder" building permit, erroneously implying that the property owner is providing
his or her own labor and material personally. Building permits are not required to be
signed by property owners unless they are performing their own work personally. Informa-
tion about licensed contractors may be obtained by contacting the Contractors State
License Board in your community or at 1020 N Street, Sacramento, CA. 95814.
PLEASE COMPLETE AND RETURN THE ENCLOSED OWNER-BUILDER VERIFICATION FORM SO THAT WE CAN
CONFIRM THAT YOU ARE AWARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED
UNTIL THE VERIFICATION IS RETURNED.
Very truly yours,
Building Department
City of Carlsbad