HomeMy WebLinkAbout2283 COSMOS CT; ; CB004760; Permit01/30/2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB004760 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 01/30/2001 2283 COSMOS CT CBAD Tl Sub Type 2130504300 Lot# $54,71200 Construction Type Reference # NEXT PROTEINS COMMERCIAL Tl COMM 0 NEW OFFICE-494SF/WAREHOUSE-OFFICE1954SF Applicant STEVE HAWKINS 1025 F STREET SAN DIEGO CA 92101 619-232-7700 Status Applied Entered By Issued Inspect Area ISSUED 12/15/2000 CB Plan Approved 01/30/2001 Owner GERRY REVOCABLE LIVING TRUST 08-06-96 2033 SHIPWAY LN NEWPORT BEACH CA 92666213 01/30/01 0002 03 CGP Total Fees $2,685 47 Total Payments To Date $275 75 Balance Due $2,409 72 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $424 23 Meter Size $0 00 Add'l Reel Water Con Fee $275 75 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1149 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 LFMZ Transportation Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL Master Drainage Fee $0 00 Sewer Fee $0 00 Redev Parking Fee TOTAL PERMIT FEES $000 $000 $000 $000 $995 80 $91920 $000 $000 $000 $000 $000 $000 $3500 $2400 $000 $000 $000 $2,68547 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees, dedications reservations or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION » CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK EST VAL < Plan Ck Deposit Validated By (" l Date / ? // <T 70-t) "2-1 ST . "7 j . &&?, Address (include Bldg/Suite Business Name (at this address) Legal Description Lot No Subdivision' Name/Ntfmber Unit N Phase No Total # of units Assessor's Parcel # 1BJAMT Existing Use Proposed Use_ALfA-/V/A- Description of Work jp CONTACT PERSON' SO FT #of Stories Name Address City State/Zip 13 ^APPLiCANT Q Contractor."- Q Agent for Contractor <[3 Owner i^JAgent:for Owner '^~" H&flfaltfi. A/A. HAWUah&WM/kJMS J&U/T&3S, /£>&> Telephone Fax # Name ' PROPERTYJJW'NER • Address City Address ,5 , tlCONTRAClOilV:: COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars Li&gpl) S^rf^/^f) & CLf~^t23~tt~T<. ll)/1 ^7*2-r-7/~l /VM tel'Tt'A/1 X**7" / //Cr"7~A " ""tJDOJx <tf rTLJlrx&L I? ItJUi £s*7/.L) m\Jy l-cs^U L*>l~,- Uli/J\\ Name State License # .J Address License Class City ' State/Zip City Business License # //if • J/ Telephone!? Designer Name State License # OY\ , Address City Telephone 6~\ ,:::rWORKERS|;cbMPENSATION ii JSC" A>- . ... ':..'".'i': ";...,..:. J" ... "" " :'":5" :'"7 Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations 0^ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued n I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are . ___ I Policy No 333-3*fS-QQ Expiration Date /<3///2Insurance Company (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) ' l~) CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secy^workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($lp0J£tf0) irCadditinn.tg the^p^t of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE ~^^J\J^^^^Z~- • K^ _ DATE I '7 :N ~^ ' ~ ' ' ' I hereby affirm that I arn exempt from the Contractor's License Law for the following reason (__1 \II I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) l~l I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement fJD YES F~lNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) __ __^ _ ____ _ 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) __ __ PROPERTY OWNER SIGNATURE DATE iCOMPLEtE THIS SECTION FOR WdW-fl£SO>eV7Mi BUILDING PJRMITS ONtW " ;:£ '' ^"''SMK^^l '"."'•".: ..- ' vj::": "=" ' ' •( Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? Q YES "S NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' [TJ YES 'p^ NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? d YES TjQ» NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER S ADDRESSLENDER'S NAME 9 :f APPLICANT CERTIFJCATiONBL * ""'*IN'a : ....... ~S. """" "" ". ~ " " ........ • ' '""'" """"""• ...... .""'" ' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required fdr excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under/ the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is noU59mmeji(ced mnhm WiO days frmn the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is c/mijjie^gd/fo/ a/penop of 180 d//s (Section 106 4 4 Uniform Building Code) APPLICANT'S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Eire Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected Bv 7#t . Inspected Bv Inspected Bv Comments CB004760 NEXT PROTEINS COMMERCIAL Tl OFFICE-494SF/WAREHOUSE-OFFICE1954SF 2283 COSMOS CT RYAN Phone 6195204927 CA Water Dist CA ^) Date -/ / Date Inspected Date Inspected Date Permit Type Sub Type Lot 0 Approved Approved Approved 03/26/2001 Tl COMM — -" Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 03/26/2001 Permit# CB004760 Title NEXT PROTEINS COMMERCIAL Tl Description OFFICE-494SF/WAREHOUSE-OFFICE1954SF Inspector Assignment TP Type Tl Sub Type COMM Job Address 2283 COSMOS CT Suite Lot 0 Location APPLICANT STEVE HAWKINS Owner PISARIKCETAL Remarks Phone 6195204927 Inspector Total Time Requested By RYAN Entered By CHRISTINE CD Description Act Comments 19 Final Structural /)r 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs PCR01048 ISSUED Inspection History Date 02/16/2001 02/15/2001 02/07/2001 02/07/2001 02/07/2001 02/02/2001 01/31/2001 01/31/2001 01/31/2001 Description 89 Final Combo 14 Frame/Steel/Boltmg/Weldmg 14 Frame/Steel/Bolting/Weldmg 34 Rough Electric 44 Rough/Ducts/Dampers 17 Interior Lath/Drywall 14 Frame/Steel/Bolting/Welding 16 Insulation 34 Rough Electric Act CO NR CO AP AP AP AP AP AP Insp TP TP TP TP TP TP TP TP TP Comments NOT COMP T-CEIL PHS 1 (TERM CEIL LITES PHS 1 RE-LOC DUCTS PHS PHS I END WIRES) 1 EsGii Corporation In Partnership >Mth Government for Building Safet> DATE 1/11/01 a AEEUCANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO OO-4760 SET II PROJECT ADDRESS 2283 Cosmos Court PROJECT NAME Next Proteins - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The items transmitted in the reemarks herewith are for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Steve Hawkins AIA 1025 F Street, San Diego, Ca 92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Steve Hawkins AIA Telephone # 619-232-7700 Date contacted /)>L,/O, (by fa*) Fax # 619-232-7770 Mail -Telephone Fax ^/ In Person [XI REMARKS The revised sheet A1 1 shows the addition of a double sink at what was the door to the wash room, please provide plumbing plans This cabinet does not allow the required 18" at the strike side of the door Please have the electrical engineer complete and sign the LTG forms By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 1/5/01 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 . EsGil Corporation In Partnership with Government for Building Safety DATE 1/26/01 a APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWERa FILE PLAN CHECK NO 00-4760 SET III PROJECT ADDRESS 2283 Cosmos Court PROJECT NAME Next Proteins - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person !X] REMARKS Applicant to remove and replace the revise sheet A1 1 to the City held sets By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 1/18/01 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 I I EsGil Corporation In Partnership with Government for Building Safety DATE 12/29/00 OAEEJJCANT JURISDICTION City of Carlsbad LJ HLAN'REVIEWER a FILE PLAN CHECK NO 00-4760 SET I PROJECT ADDRESS 2283 Cosmos Court PROJECT NAME Next Proteins-TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person [X] The applicant's copy of the check list has been sent to Steve Hawkins AIA 1025 F Street, San Diego, Ca 92101 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Steve Hawkins AIA (V-M.} Telephone # 619-232-7700 Date 8S&8SFhri<\re» (by &K) Fax # 619-232-7770 Mail -^ Telephone-^ Fax ~* In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 12/20/00 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 00-4760 12/29/OO PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO OO-476O OCCUPANCY B/ S-2 TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 12/15/00 DATE INITIAL PLAN REVIEW COMPLETED 12/29/00 JURISDICTION City of Carlsbad USE Office/ Warehouse ACTUAL AREA 1954 STORIES 2 HEIGHT OCCUPANT LOAD 22 DATE PLANS RECEIVED BY ESGIL CORPORATION 12/20/00 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked UP list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad 00-476O 12/29/OO Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete * 1 Please note on the plans "AC Cable is not allowed NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" Per City of Carlsbad 2 Please provide construction details to show the new guardrail and handrail to comply with sections 509 and 1003 3 3 6 of the UBC 3 Please provide construction details for the new soffits in the lobby 4 Please revise the detail for the full height partition wall to show the type, spacing and ICBO # of the attachment to the concrete slab 5 Please revise the detail for the construction of the new hard-lid ceilings in the rated and non-rated hallways and office # 132 to show the size, type spacing and of the ICBO# of the ceiling joists To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list9 Please indicate Yes a No a City of Carlsbad OO-476O 12/29/OO The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad 00-4760 12/29/00 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PREPARED BY Doug Moody BUILDING ADDRESS 2283 Cosmos Court PLAN CHECK NO" OO-4760 DATE 12/29/00 BUILDING OCCUPANCY B/S-2 TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 1954 cb Valuation Multiplier 2800 By Ordinance 1994 UBC Building Permit Fee ^ Reg Mod VALUE ($) 54,712 54,712 42420 1994 UBC Plan Check Fee Type of Review I I Repetitive Fee ' Repeats 0 Complete Review D Structural Only Q Other D Hourly Esgil Plan Review Fee Comments 27573 220 58 Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB U-O DATE 12^-ZLg -Q CD ADDRESS 2.2.%-z,CT RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEE DATE Oocs/Mlsforms/Planmng Engineering Approvals Carlsbad Fire Department 004760 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Hawkins & Hawkins 1 025 'F1 Street City, State San Diego CA 92101 Plan Checker Job Name Next Proteins Job # 004760 Job Address 2283 Cosmos Court Bldgfl CB004760 Ste orBldg No D Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Approved The item you have submitted for review has been approved subject to the Subject to attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 9nr) 3rd 004760 FD File # Other Agency ID . Requirements Category:Building Plan Requirement Pending 0514 Provide Technical Report To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to the inspection of the department, the Chief is authorized to require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and the facilities and appurtances situated thereon, to recommend necessary changes Requirement Pending 0532 Additional Requirements or Comments Is Next Proteins Interior Improvements an existing tentant if not provide details on warehouse use and stroage racking system Provide comment on plan If building is fire sprinkled add to Construction type information on first page Remove Fire Sprinkler from deffered submnttals Plans to be submitted and approved before final on building Requirement 0533 Plan RevisionsPending Please submit 3 sets of corrected plans directly to the Building Department for routing to the appropriate departments Page 1 01/16/01 Cansbad Fire Department 004760 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 12/19/2000 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Hawkins & Hawkins 1025 F Street City, State San Diego CA 92101 Plan Checker Job Name Next Proteins Job # 004760 Job Address 2283 Cosmos Court Bldg # CB004760 Ste or Bldg No D Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards ' Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2nd 3rd 004760 FD File # Other Agenr.y ID li. Requirements Category:Building Plan Requirement Pending 0525 Exit Signs Section 1013 1 Where Required When two or more exits from a story are required by Section 1013 4, exit signs shall be installed at stair enclosure doors, horizontal exits and other required exits from the story When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction of egress EXCEPTIONS 1 Mam exterior exit doors which obviously and clearly are identifiable as exits need not be signed when approved by the building official 2 Group R, Division 3, and individual units of Group R, Division 1 Occupancies 3 Exits from rooms or areas with an occupant load of less than 50 when located within a Group I, Division 1 1, 1 2 or 2 occupancy or a Group E, Division 3 Day-Care occupancy Illumination Signs shall be internally or externally illuminated by two electric lamps or shall be of an approved self-luminous type Power Supply Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system Power to the other lamp shall be from storage batteries or an on-site generator set Show all existing exit signs on first floor if needed add signs Requirement Pending 0532 Additional Requirements or Comments Is Next Proteins Interior Improvements an existing tentant if not provide details on warehouse use and stroage racking system Provide comment on plan If building is fire sprinkled add to Construction type information on first page Remove Fire Sprinkler from deffered submnttals Plans to be submitted and approved before final on building Requirement Pending 0533 Plan Revisions Please submit 3 sets of corrected plans directly to the Building Department for routing to the appropriate departments Page 1 12/19/00 TffLE 24 REPORT Title 24 Report for: NEXT PROTEINS COSMOS COURT' CARLSBAD, CA Project Designer: Report Prepared By: HADIMAHZARI ENERGY CONSULTING GROUP 8015 BALBOA AVENUE SAN DIEGO, CA 92111 (858) 268-0660 Job Number: •• T-'-1" - ";.;:Vt • S-^.;:-i,-'..- Date: 12/12/00 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards This program developed by Gabel Dodd/EnergySoft LLC (415)883-5900 EnergyPro 21 'By EnergySoft Job Number User Number 2984 TABLE OF CONTENTS Cover Page Table of .Contents Nonresidehtial Performance Title 24 Forms Form MECH-MM Mechanical Mandatory Measures 11 m EnergyPro 2 1 By EnergySoft Job Number User Number 2984 PERFORMANCE CERTIFiCAJE OF COMPLIANCE Part 1 of 3 PERF-1 PROJECT NAME NEXT PROTEINS PROJECT ADDRESS 2283 COSMOS COURT CARLSBAD PRINCIPAL DESIGNER - ENVELOPE DOCUMENTATION AUTHOR ENERGY CONSULTING GROUP TELEPHONE TELEPHONE (858) 268-0660 DATE 12/12/00 Building Permit* ' \* Checked by/Date /:-j Enforcement Agency Use '"* IGENERAL INFORMATION DATE OF PLANS BUILDING TYPE PHASE OF CONSTRUCTION IS D BUILDING CONDITIONED NONRESIDENTIAL NEW CONSTRUCTION *• D G FLOOR AREA 861S HIGH RISE RESIDENTIAL ADDITION m ALTERATION qFt D n CLIMATE ZONE . ^, HOTEL/MOTEL GUEST ROOM EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code This certificate applies only to a Building using the performance compliance approach DOCUMENTATION AUTHOR HADI MAHZARI SIGNATURE DATE The Pnncipal Designers hereby certify that the proposed building design represented "in the construction documents and - ' ;. •;- ; modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6 ENV LTG MECH j | l_J [ | 1 I hereby affirm that I am eligible under the provisions of Division 3 of the B Code to sign this document as the person responsible for its preparation, an engineer, mechanical engineer, electrical engineer or architect I I FT' ^Xi 2 ' a^rm tnat ' am el|9|b|e under the exemption to Division 3 of the Business ' Section 5537 2 of the Business and Professions Code to sign this document its preparation, and that I am a licensed contractor prepanng documents for perform I I ! | i 3 I affirm that I am eligible under the exemption to Division 3 of the Business ' — ' ' — ' L — ' Section of the Code to sian this doc responsible for its preparation, and for the following reason usmess and Professions d that I am licensed as a civil ; and Professions Code by as the person responsible for work that I have contracted to i and Professions Code by :ument as the person ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures - Required Forms ENV-1 PRINCIPAL ENVELOPE DESIGNER - NAME " SIGNATURE LIGHTING COMPLIANCE LIC NO DATE I Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of I Required Forms Thls Subm'^' PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LIC NO DATE i Required Forms MECH-1, MECH-2, MECH-3 PRINCIPAL MECHANICAL DESIGNER - NAME i SIGNATURE . DSD MECHANICAL LT^x-^t^HU LIC NO ;DATE, , L Run Initiation Time 1.2/12/0014 18 18 Run Code 976659498- I EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 3 of 12 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-l| NEXT PROTEINS JDATE i 12/12/00 ANNUAL SOURCE ENERGY USE SUMMARY (kBtu/sqft-vr) Standard ENERGY COMPONENT Design Spac Spac e Heating 28 57 e Cooling 33 so Indoor Fans 27 53 Heat Rejection o ooi Pumps oooi Domestic Hot Water ^ o ooj Lighting ! 35 19J Receptacle 22 65 Process 1707J TOTALS 16481 Proposed Compliance DeSICjfl Margin Hpsl'SlandOTl^ '-•*-'•> ^ 4 -y^"^^""^"- ~* "^M "Proposed- i\'\ j-;A ;!l. v'r.:V' '-i* •«H1 ->nq ^i««(«« ^gggJ^2SSS2ai2ii^4 %*-*.- :.i!-;i ooo i o oo ' S'^s^i! '^f:^ M:'-^:' !'••«"-*" "•• •>'/"-' '• 'T^-rr'x; 000 000 . tj&SS&ait'a "ySV'3'.-a ..•'-""•'•?;"/.<" r.,'v-': ;;"" '-.-. *-fM-L .'.•; t F °°° °°° filllS ?$<££"• '''•• -'^%v-"^ • i . *>,?'••?££»-- JS«B8i*isS^^^;i^'*4?jV.r;f ''W^isSi^'W ;•' 2265 000 • S^^^-iiSiiSSiiBliiU / t"\:-.. : ! 170? Qoo ' :-r:,ftsk->.-^i 14948 1533 '2^:'^^^ft:^:'>4!lffll BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones I (North) Odeg Conditioned Floor Area 861 sqftI1 Unconditioned Floor Area 8,750|sqfti 1 Conditioned Footprint Area 86i|sqft 2 Front Elevation Left Elevation Rear Elevation Right Elevation Total Roof Lighting Power Density Orientation Gross Area Glazing Area Glazing Ratio i (North) 810 sqft 18' sqft i 22%; (East) 0 sqft 0 sqft j 00%. i • i : (South) 0 sqft 0 sqft i 0 0% I (West) 864 sqft 36 sqft i 42%! 1,674 sqft 54: sqft I 32%: i 861 sqft Oisqft • 00%: Standard Proposedi ; I 1200w/sqft 1 200!W/sqft Prescriptive Env Heat Loss 1.313J 957; Prescriptive Env Heat Gam j 36,284 21,262: \ Remarks Standard Bui/ding (Compliance) , • i Run Initiation Time 12/12/00 14 18 18 .' Run Code 976659498 EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 4 of 12 -4? 3% PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME NEXT PROTEINS DATE 12/12/00 ZONE INFORMATION System Name HP-1 - Zone Name HP-1 HAREHOUSE | j i * : I Occupancy Type Comp Bldg Office Unconditioned j ', i j Floor Area (sqft) 861 8,750 Inst LPD (W/sf)1 *1 200 0000 Notes 1 See LTG-1 (items marked with asterisk see LTG-2 by others) 2 See LTG-3 3 See LTG-4 Ctrl Credits (W/sf)2 •• Tailored LPD (W/sf)3 _ Vent,(cfm/sf) 015 i"*- ii i .,- I | j Proc Loads (W/sf) 1 1000 j I II Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST I The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the speciaijustifjcatior^ and documentation submitted i plan I Field I i i j \i \ I j i I The exceptional features listed in this performance approach application have specifically been reviewed Adequate written justification and documentation for their use have been provided by the applicant Authorized Signature or Stamp. L . Run Initiation Time J2/12/00 14 18 18 Run .Code 976659498 I EnergyPro 2 1 By EnergySoft User Number 2984 Job Number-Page 5 of 12 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAMENEXT PROTEINS OPAQUE SURFACES # 1 2 3 4 5 6 7 Surface Type Wall Wall Wall Wall Wall Wall Framing Type Area Metal 210 None 294 Metal 162 None 126 Metal 240 None 336 Wall |Metal 84 8 Wall iNone 168 9 Demising Metal 500 AU-Val A3 0272 0709 0272 0709 0272 2 0709 2 0272 ,_3 0709 3 0194 10iRoof jWood 861 0056 ; I I DATE 12/12/00 I Solar ct. Gams :m Tilt Y/N Form 3 Reference Location / Comments 0 90 0 90 15 90 »5 90 70 90 70 90 X i 7" Concrete Wall/ R-1 1 ! HP-1 & 7" Cone Wall HP-1 X 7" Concrete Wall/ R-1 1 HP-1 XJ 7" Cone Wall HP-1 £1 7" Concrete Wall/ R-1 1 HP-1 XM 7" Cone Wall HP-1 15 90 X | 1 7" Concrete Wall/ R-11 HP-1 15 90 vj i 7" Cone Wall HP-1 I 0 90 0 0 - X\ R-1 1 Metal Stud Wall HP-1 (faces WAREHOUSE) Xl R-1 9 Roof (R 192x8 16) HP-1s I ! i j j I ~~ i FENESTRATION SURFACES # 1 2 Type Window Window Area U-V 18 1 1S 36 1 1S j - i Act. al Azm. )0 45 )0 315 SHGC Glazing Type Location / Comments 0 83 I Smale Mtl Uncoated Default hP-1 0 83 I Single Mtl Uncoated Default JHP-1 i ! ! i i EXTERIOR SHADING # 1 2 Exterior None None I !Shade Type iSHGC ! 076 076 Window Overhang Left Fin Right Fm Hgt Wd Len Hgt LExt RExt Dist Len Hgt Dist Len Hgt : j i i j | i I i | ! : j I I Run Initiation Time 12/12/0014.1818 Run Code 976659498 I EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 6 of 12 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME NEXT PROTEINS DATE 12/12/00 ISYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN AIR CFM (MECH-3, COLUMN H) HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER HEATING DUCT LOCATION COOLING DUCT LOCATION DUCT TAPE ALLOWED? R-VALUE R-VALUE I MECHANICAL SYSTEMS HP-1 Programmable Switch No Setback Required n/a Yes OQJjW Constant Volume No No Constant Temp Constant Temp Air Balance Auto No Economizer 129 cfm Heat Pump 6 8 HSPF Packaged DX 100 SEER /90EER ICP PHF036HOOO Ducts in Attic Ducts in Attic PIPE TYPE (SUPPLY, RETURN, ETC ) PIPE INSULATION REQUIRED? 42 42 Yes Yes -. - • -- i ! NOTE TO FIELD ' •>. -> ! . ... CODE TABLES Enter code from table below into columns above j HEAT PUMP THERMOSTAT? ELECTRIC HEAT? VAV MINIMUM POSITION CONTROL? i SIMULTANEOUS HEAT / COOL'' HEAT AND COOL SUPPLY RESET? HIGH EFFICIENCY? ! DUCT TAPE ALLOWED? PIPE INSULATION REQUIRED' TIME CONTROL SETBACK CTRL S Prog Switch H Heating O Occupancy C Cooling I Sensor B Both Y Yes M Manual Timer VENTILATION OUTDOOR DAMPER B Air Balance A Auto C Outside Air Cert G Gravity M Out Air Measure D Demand Control N Natural ISOLATION ZONES Enter Number of Isolation Zones ECONOMIZER A Air W Water N Not Required FAN CONTROL I Inlet Vanes P Variable Pitch V VFD O Other C Curve | OA CFM Enter Outdoor Air CFM i Note This shall be no j less than Col H on MECH-3 j INOTES TO FIELD - For Building Department Use Only Run Initiation Time 12/12/0014 18 18 Run Code 976659498 EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 7 of 12 MECHANICAL EQUIPMENT SUMMARY Parti of2 MECH-2 PROJECT NAME NEXT PROTEINS DATE 12/12/00 CHILLER AND TOWER SUMMARY Equipment Name Equipment Type Qty Efficiency Tons PUMPS Tot Qty GPM BHP Motor Eff Drive Eff Pump Control DHW / BOILER SUMMARY System Name System Type Distribution Type Qty Rated Input Vol (Gals ) Energy Factor or Recovery Efficiency Standby Loss or Pilot TANK INSUL. Ext R-Val CENTRAL SYSTEM RATINGS System Name ICP PHF036HOOO System Type Packaged DX Qtv 1 HEATING Output 32,000 Aux kW 00 Eff COOLING Output 6 8 HSPF 34 000 Sensible Efficiency Economizer Type 27,200nO 0 SEER /9 0 EER jNo Economizer I j ICENTRAL SYSTEM FAN SUMMARY System Name I Fan Type ICP PHF036HOOO |Constant Volume !i i SUPPLY FAN RETURN FAN Motor Location Draw-Through ! | I i i I ii i i i CFM 1,200 Motor Drive • : Motor ! Drive BHP Eff Eff CFM BHP I Eff i Eff I i :• | 033i 770% 1000%,; none! j 1 i j i i! ! i I! ! |i i i : i i !:. ; 1 '; ! i ! -i ; i 1 ! !! • : 1 Run Initiation Time 12/12/0014 18 18 Run Code 976659498 EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 8 of 12 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME NEXT PROTEINS DATE 12/12/00 ZONE TERMINAL SUMMARY Zone Name ..;-' ••. • -. ., 1 I VAV TERMINAL BOX System Tvoe •- ;•• EXHAUST FAN SUMMARY Qty Mm CFM Ratio — Reheat Coil Type iDeltaT i i i i Flow Ratio TERMINAL FAN CFM ! i ! : i i EXHAUST FAN ; Room Name Qty CFM ! i BHP Motor Eff Drive Eff i I ii BMP Motor] Drive Eff ! Eff j i 1 BASEBOARD Type , j i • i ! _J Output |! II i ii "" j| : 1 ! !i i ! ; i EXHAUST FAN Room Name I Qty CFM BHP Motor Drive Eff : Eff Run Initiation Time 12/12/00141818 Run Code 976659498 EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 9 of 12 MECHANICAL VENTILATION MECH-3 PROJECT NAME NEXT PROTEINS DATE 12/12/00 1 MECHANICAL VENTILATION Ej K ZONE/SYSTEM HP-1 HP-1 •-• AREA BASIS COND AREA (SF) 861 i 1 CFM PERSF 015 MIN CFM (BxC) 129 OCCUPANCY BASIS NO OF PEOPLE 86 CFM PER PERSON 150 i i ! I MIN CFM (ExF) 129 Total ; I j j ;• i ! | i ; REQ'D OA (MAX OF OORG) 129J 129 DESIGN OUTDOOR AIR . CFM VAV MIN RATIO 1291 129J ! i i ! i I — - i ! •: ' b TRANS- FER AIR — i i I I I i i | C Minimum Ventilation Rate per Section 121, Table 1-F i E I Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density i I | Must be greater than or equal to H, or use Transfer Air Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans | K | Must be greater than or equal to (H minus I), and, for VAV, greater than or equal to (H-J) EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 10 of 12 MECHANICAL MANDATORY-MEASURES Parti of2 MECH-MM PROJECT NAME NEXT PROTEINS DATE 12/12/00 DESCRIPTION Designer [Enforcement Equipment and Systems Efficiencies I §111 §115(a) §123 §124 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard Fan type central furnaces shall not have a pilot light Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code Controls § 122(e) Each space conditioning system shall be installed with one of the following | § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours The time switch shall be capable of programming different schedules for weekdays and weekends, incorporate an automatic holiday "shut- off* feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation, and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted, or § 122(e)1B An occupancy sensor to control the operating period of the system, or § 122(e)1 C A 4-hour timer that can be manually operated to control the operating period of the system § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpomt. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones Each zone shall not exceed 25,000 square feet, shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas, and shall be controlled by a time control device as described above j • § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone Where used to control heating, the control shall be adjustable down to 55 degrees F or lower For cooling, the control shall be adjustable up to 85 degrees F or higher Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum I ! § 122(c) Thermostats shall have numeric setpomts in degrees Fahrenheit (F) and adjustable setpomt stops accessible only to authorized personnel | ' § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone EnergyPro 2 1 By EnergySoft User Number 2984 Job Number =age 11 of 12 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME NEXT PROTEINS DATE 12/12/00 Description Designer Enforcement Ventilation [X~| § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans [X~| § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems [X] § 122(f) All gravity ventilating systems shall be_provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings iXJ § 121(f)1 Air Balancing The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989), or [X~j §121(f)2 Outside Air Certification The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system, or I i §121(f)3 Outside Air Measurement The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice, or | | §i21(f)4 Another method approved by the Commission Service Water Heating Systems [X~| § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required [X~j § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F jXJ § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following Outlet devices that limit the flow of hot water to a maximum of 0 5 gallons per minute Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0 75 gallons per minute Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0 75 gallons per minute Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2 5 gallons per minute, and 0 25 gallons/cycle (circulating system) Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2 5 gallons per minute, and 0 50 gallons/cycle (non-circulating system) Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2 5 gallons per minute, and 0 75 gallons/cycle (foot switches and proximity sensor controls) EnergyPro 2 1 By EnergySoft User Number 2984 Job Number Page 12 of 12 Sent By HHfc CONSUL!ING,INC ,858 5?8 4761 ,jan-23-01 9 04AM,Page 1/3 CERTIFICATE OF COMPLIANCE PROJECT HAMS NEXT PROTtENS PROJECT ACCKESS COSMOS COURT. CARLSBAD. CA 'RINCIPAL. OesiGNER-UGHTING RANDY MINNIER DOCUMENTATION AUTHOR JOHN IMIG Ch«k«l by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PUNS 19-Jarv01 BUILDING FLOOR AREA 861 CLIMATE ZONE BUILDtNO TYPE NONRESIDENTAIL HK3H RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ALTERATION UNCONDITIONED ,n.- METHOD OF LIGHTING COMPLIANCE nCOMPLETE BLDG AREA CATEGORY TAILORED ERFORMANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists trie building features and performance specifications need to comply with Title 24. Parts 1 and 6 of the California Code Regulations This certificate appl.es only to building lighting regulations Tha documentation prepareer hereby certifies that the documeij ccurate and complete DOCUMENTATION AUTHOR RANDY MINNIER SIGNATUI 19-Jan-01 The Principal Lighting Designer hereby certifies that the proposws building design represented in this set of construction documents is consistent wtth the other comptanc* forms and workshets with the specifications, and with any other Calculations submitted with this permit application The proposed building has been designed to meet the envelope requirements contained In me application parts of Sections 11C. 119.130 through 132,146, and 149 of Title 24, Part 6 Please check one [x| I hereby affirm that I am elibible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation and that I am licensened I the State of California as a ovil engineer or electrical engineer, or I am a licensed architect I affirm that I am eligible under t5he provisions of Division 3 of the Business and Professions Code by section 5537 2 or 6737 3 to sign this document as the person responsible for its preparation, and that I am a licensed contractor performing mis work I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work descnbed as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737 1 (These sections gf the Business and Prj printed ip full in the Nonrssidential Manual) W1NCIPAL LIGHTING DESIGNER-NAME RANDY MINNIER DAT6 1/19/01 E015703 LIGHTING MANDATORY MEASURES Indicate locator* on plans of Note Stock for Mandatory Measure [EI 2 INSTRUCTIONS TO APPLICANT For detailed instructions on J/» ws& o/ ihts and all Energy Efficiency Standards compliance forms, pfease rarer to tfie Nonr9$id9ntta1 Manual published by the California Energy Commision LTG-1 Required on plans for all submittals Part 2 may be incorporated in schedu/es Oft plans L TG-2 Required for all subrmttals LTG-3 Optional Use only if lighting control credits are taken LTG-4 Optional Use only ff TaOor&d Method fs used Paris 2 and 3 used onfy if applicable Nomesfeenotf comonaixx form Sent By MPE CONSULTING;INC ,858 578 4761 ,Jan-23-01 9 05AM,Page 2-'3 CERTIFICATE OF COMPLIANCE (2 of 2) LTG-1 BROJECTNAM6 ^^^ pROT)ENS OM* 19-Jan-01 INSTALLED LIGHTING SCHEDULE LUMINAIRE MAMS F1 LAMPS lype I h X M * 3 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Rooms) CONTROL IDENTIFICATION Wans Per Lamp 32 BALLASTS Type "!>& X u CONTROL TYPE (Auto Time Switch Extenor ere) » 2 Lumnare (Lamps & Ballast) »wans SPACE CONTROLLED NOTE TOFIELD NOTE TO FIELD CONTROLS FOR CREIDT CONTROL LOCATION (Room » or Drawing*) CONTROL IDENTIFICATION CONTROL TYPE (Occupant Daylight. act) LUMINAIRE5 CONTROLLED TYPE # NOTE TO FIBD NOTE TO FIELD - For Building Department Use Only NonresldenVal CompRsnc* Form November 1999 Sent By MPE CONSULTING,INC ,858 578 4761 Jan-23-01 9 05AM,Page 3/3 LIGHTING COMPLIANCE SUMMARY LTG-2 TOJ6CTNAV6 NEXTPROTIENS ACTUAL LIGHTING POWER NAME F1 2"X4l FLUORESCENT TROFFER U not using m« CEC Ovfaull value please provria supporting documentation. NUMBER OF UJMINAIRES 12 WATTSA.UMINAIRE (including Baffast) 90 CECDEFAUIT9 Y N X SUBTOTAL FROM TWS PAGE PLUS SUBTOTAL fROM CONTINUATION PAGE LESS CONTROL CREDIT WATTS (From LTG-3) ADJUSTED ACTUAL WATTS TOTAL WATTS 1080 0 0 0 0 0 0 0 0 0 0 1080 I ALLOWED LIGHTING POWER (Choose One Method) COMPLETE BUILDING METHOD BUILDING CATEGORY (Fiwn HC(b)Tabte 1-M) WATTS PERSF COMPLETE BLDG AREA ALLOWED WATTS 0 AREA CATEGORY METHOD AREA CATEGORY (Prom 146(b) Table 1 N) OFFICE WATTS PERSF 1 3 TOTALS AREA (SF) 861 861 AREA ALLOWED WATTS 11193 0 0 0 0 0 0 0 0 0 11193 WATTS TAILORED METHOD NonmdunHalCamfMenceFarrn TOTAL ALLOWED WATTS (From LTG-4. or from Computer Run) Norvmter 1»»S m JSCLUJ m LU LL _ -5 O 2 O \- -J <ch-ni ' 1r c 1•)-^ ^ «1 ^-wd\ ^ £f-^ 4 rauj '•§\0^ V4r"A^4_5\ ^>^c^\<K"~" 1 f^» ~ I— - ' . <N1 i —>_/-N^^<i•~- —*- ••^^>1•^u: £,<J\iy\^^ ^ ^: '^D.^^Mr, \ -QU-^iLr ^ T- ^ ^ \^4 ^^ 14- ^^>~v ^>^O^r1> -^ ^^t3 ^^*^ VJ\i 6 'v ^.^ ({^ " 4J3^ ^- -^ sp - • 5 ^ ^ tf ^. ._.. ^ v£ V 3* N la- COO, Hio Pt ^9 O m OT rv — , ^-i§ iS uj < O C£ I U $ in <f) < >~Z. £ S LUy ws^ 'iv*:/) \J )li -> vJ - OA ^ ^JVJ ^>- S" V ^ <SS A ^ ^ ^ ^ i~-4- v ^ ^ 6 ^ oS ^ ^ ^ ^ 4 $JS ^?^3V^ ^ 6.^ C\ ^UJ r\ ^-^ ^->/ O ^ o -A v- \r \f\ ^ 9 J r n "^Iv 03/01/2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR01048 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title Applicant HAWKINS STEVE 619232-7700 2283 COSMOS CT CBAD PCR 2130504300 Lot# 0 $0 00 Construction Type UN CB004760 NEXT PROTEINS RACKS SHOWN ON ORIGINAL T I PLANS Status Applied Entered By Plan Approved Issued Inspect Area Owner GERRY REVOCABLE 2033 SHIPWAY LN NEWPORT BEACH CA 92660 ISSUED 02/15/2001 MDP 02/27/2001 03/01/2001 3-9602 01 02 218-00 Total Fees $21800 Total Payments To Date $000 Balance Due $21800 Plan Check Revision Fee $21800 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside, void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes nor planning zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired Feb-15-Ol O2:O2P Hawkins & Hawkins Ar-chite ILU u ruui inu 1C. IU rn utn ur WUtLSBKU FHX NW. IbU bll<-' BW>H P 01 FOR OFFICE USE ONLY PERMIT APPLICATION ^^K I PLAN CHECK NO ^ CITY OF CARLSBAD fiUiLUING DEPAHTMFNT •• - >S>^H IEST VAL 1635 Faraday Ava . Cartsbad CA 82008 P. 02 ^>»L-OK\fl|)C tMg.ftott.-t- T'lt ' ifcs&vs»aw -;*; 70)) 66u««o,p~>(>t<ifuii»i. cow A^rC>tirvCgiiinvMM)if«4un»pKmincan«ti«i tint imtn^., (Wmwin/oew •«» rt/vmf», oiw I <M «ww> « not CKr im. 3r«!« uctrtfe c TMIMM 'i-^V-!l^^« -v . ft^va;™- ,-* unto pouh, m ^qwv fix <« IM IMMM dtclK.! Q iiun*^»um^ni^i<!«>te&=<cq^OTra>il'>^ii<'*iw«Dn««'Mmc«a«iMupf«v<*MkvI>oiM}7aa^iiugftfw wwll tar wfachtf*«PBn*TlvlIhMd D I «•-« Ml •* iminun irarkm wnwr-wcon, M ;•»««) b, •Wrton 1700 of *• HOW CMf f« iht ,».rh>i<ma «> mt wort for whch inn pvim I) U CHTWCATf Of «XlHTTK»I >I\MI Ml »>«ll>« Kvy toim In <n, Q i M o-«-. rf IK. MM MOM <y» VMI «f «m»mftM, tW owM^MMx wn Kt.. th, turAn of •»»<>« *.i N. gig ih. 1 I HnoMlly »!». to (»«iq. ih. ~«o. litol .n. nmf,|r» roc COMBurtM M «• ITUMM n«MH> (JI I !(K»<ytav>ra>i)Mn^WiWpilewM<ai<«uiUingiMnnTr»' ] I iww MAMMA v«i m. Wrooring pngi. Mm) n MO>M> «w O ¥K / IN>** numBrr / cinincn» licin« nunM>> M»i»w^MIMMbpn^ -rf--i=i>. .-. - y ,•„ PI ''I* CJ NO lllU(««ll«VW»><onRTUCUdiiriIrM)'.aOOr«(iaiaw«<it>r>>ndiivi>l>Kl>*«IM»' O TIZ D NO Jfil/tl CM CaaM W.,, in* K-'I»W^> ft it» wo« m « tlMuui i *penfct ^lt^tm4<^t^-^t^l^nm-fMt»iitOimmlvnM^ttU«tCltMI«fiaif^vn*tivim»tfaM^.=^,t, \ n*, t, *MI»ty wt«h •« Cur oMMTKU «nd «u» m» tMM»« u MW* tDMBuoiMl I Mniv M»«ii. nfimMuani if IM C»t of C«Kt«« to rritr upon «• atooo mnraoMa (W uUMCto IWMMI I ALSO AOHt TO SAM, MOOHMV MO HOP *ARMUH THE OTV «f CATKHU AOAUnT 4U. kMHUKtlfmnHOupni af tut e«HTW9 o» Tfta riBMiT HUI B«M B)f MKUM >M «WMh« nvl art nU » «. kuDdhg «<«oA HdM«OwtmW<r«<l UrtOnn AudUrg COM) DATE . EsGii Corporation 2/i fartners/tip with. Qove.rnrw.nt for ZBuififinff Safety DATE 2/23/01 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO OO-4760 rev(PCR01048) SET I PROJECT ADDRESS 2283 Cosmos Court PROJECT NAME Storage Racks for Next Protein I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) ( / j Fax # Mail Telephone Fax In Person X] REMARKS 1 Fire Department apprawajJiJS required 2 Note on the plan that the rack design loads will be posted per section 2225 of UBC By David Yao Enclosures Esgil Corporation D GA D MB D EJ G PC 2/15 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858) 560-1468 ^ Fax (858) 560-1576 Carlsbad OO-4760 rev(PCRO1048) 2/23/01 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad rev(PCR01O48) PREPARED BY David Yao BUILDING ADDRESS 2283 Cosmos Court PLAN CHECK NO 00-4760 DATE 2/23/O1 BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING PORTION storage racks Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Valuation Multiplier By Ordinance Bldg Permit Fee by Ordinance 1 T Reg Mod VALUE ($) Plan Check Fee by Ordinance $21788 Type of Review _ Q Repetitive Fee ! "v Repeats D Domplete Review D Other PI Hourly Structural Only Hours * Esgil Plan Review Fee $17430 Based on hourly rate Comments Sheet 1 of 1 macvalue doc SEIZMIC MATERIAL HANDLING ENGINEERING EST 1985 STORAGE RACKS DRIVE-IN RACKS CANTILEVER RACKS MEZZANINES CONVEYORS CAROUSELS STEEL SHELVING MOVABLE SHELVING STORAGE TANKS MODULAR OFFICES GONDOLAS BOOKSTACKS CITY APPROVALS STATE APPROVALS PERMITTING SERVICES PRODUCT TESTING FIELD INSPECTION SPECIAL FABRICATION ALASKA ARIZONA CALIFORNIA COLORADO IDAHO MISSOURI NEVADA NEW MEXICO OREGON PENNSYLVANIA UTAH WASHINGTON SEISMIC ANALYSIS OF STORAGE RACKS FOR NEXT PROTEIN COSMOS COURT CARLSBAD, CA 92009 #01-01 161 ATLANTIC STREET • POMONA • CA 91768 • TEL (909)869-0989 • FAX (909)869-0981 PROJECT NEXT PROTEIN CS GOODALE SHEET NO ± OF UL MATERIAL HANDLING ENGINEERING ROBS 01-29-2001TEL (909)869-0989 • FAX (909)869-0981 - CALCULATED BY PUP 5- DATE Ul ** ^UU ' 161 ATLANTIC STREET • POMONA • CA 91 768 TABLE OF CONTENTS DESCRIPTION PAGE # COVER SHEET 1 TABLE OF CONTENTS 2 SCOPE 2 PARAMETERS 3 CONFIGURATIONS 4 - 4 COMPONENTS & SPECS 5- 6 LOADS AND DISTRIBUTION 7 LONGITUDINAL ANALYSIS 8 COLUMN 9 BEAM 10 BEAM TO COLUMN ' 11 BRACING 12 OVERTURNING 13 BASE PLATE 14 SLAB & SOIL 1 5 SCOPE: THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY, WITHOUT ANY FIELD WELDING PROJECT, FOR NEXT PROTEIN CS GOODALE SHEET NO MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91768 OF_15 CALCULATED BY_BOBS DATE.01-29-2001 HAHAMEI STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH DIRECTIONS WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN ANY ADJACENT BAYS THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYZED IN BOTH LONGITUDINAL AND TRANSVERSE DIRECTION STABILITY LONGITUDINALLY IS DEPENDANT ON BEAM TO COLUMN MOMENT, WHILE THE BRACING ACT TRANSVERSELY 1 COLUMN 2 BEAM 3 BEAM TO COLUMN 4 BASEPLATE 5 HORIZONTAL BRACING 6 DIAGONAL BRACING 7 BACK CONNECTOR TRIBUTARY AREA I TRANSVERSE I LONGITUDINAL TOP VIEW PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO 4 OF.15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA « CA 91 768 CALCULATED BY_BOB S DATE.01-29-2001 CONFIGURATIONS TYPE S/R 88" 180" Olb 3,000lb r42" 42" 96"<• 42"-^ TYPE D/R 88" 180" Olb 3,000 Ib 96" r42" 42" 42" 42" *• 42" -» PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 OF 15 CALCULATED BY BOBS.DATE.01-29-2001 TYPE S/R SPECIFICATION - MAIN STEEL 50000 PSI - BASE PLATE STEEL 36000 PSI - ANCHOR - WEDGE TYPE 1/2x3-1/2 - FLOOR SLAB 5" X 2000 PSI REINFORCED 1 80" - SOIL BEARING PRESSURE 1000 PSF - SEISMIC ZONE 4 - TYPE = SINGLE ROW UNITS ~*' 8 180" -} 8 I C 5" j / Olb / 2 v_-^/ 3 000 Ib 1 f OiC" £. I # "14 / 4 421# 4 /4 2" >" 2" ,s \ \ / / \ \ / 1 /ion o o S3I SECTION AXIAL FORCE MOMENT lu= 96" BEAM MOMENT 1 1,600tb 12, 520 in Ib 2 50 Ib 605 in Ib 8,562 in Ib <-std conn 303 in Ib <-std conn TYPE S/R DESIGN LOAD = VARIES BASE PLATE V 8X5X 375 Mbase= 6337 m Ib OVERTURNING V ANCHOR STRESS = 0 08 # OF ANCHORS = 2 COLUMN V 3X3X1 2GA COLUMN STRESS =0 47 BRACING HORIZONTAL ^/ DIAGO 1 1/2X 1 1/ZX 1/4X 16GA 1 1/2 XI 1/2 X STRESS = 010 STRESS = BEAM 4-3/1 6X2-1 /2X1 4GA(BB3) M AX LOAD/LEVEL = 4 , 9 7 3 I b BEAM IS O.K. SLAB & SOIL NAL V V 1 /4 X 1 6 GA PUNCT STRESS = 029 0 1 6 BENDING STRESS =0 1 7 PROJECT. FOR NEXT PROTEIN CS GOODALE MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 SHEET NO . OF.15 CALCULATED BY.BOBS.DATE.01-29-2001 TYPE D/R SPECIFICATION - MAIN STEEL 50000 PSI - BASE PLATE STEEL 36000 PSI - ANCHOR - WEDGE TYPE 1/Z x 3-1/2 - FLOOR SLAB 5" X 2000 PSI REINFORCED 1 80" - SOIL BEARING PRESSURE 1000 PSF - SEISMIC ZONE 4 - TYPE = INTERCONNECTED UNITS 8 180" T 8 5" r 5" ' 2 3,000lb 1 2 QC» r 4 4 223#, 4 : 7" J" ?" f L \\/ / \\/ 1 yIO»— , •MIIMMM 28' SECTION AXIAL FORCE MOMENT lu= 96" BEAM MOMENT 1 l,600lb 5, 009 in Ib 2 50 Ib 321 mlb 4,665 in Ib <-std conn 161 m Ib <-std conn TYPE D/R DESIGN LOAD = VARIES BASE PLATE V 8X5X 375 Mbase= 5008 in Ib OVERTURNING V ANCHOR STRESS = 0 05 # OF ANCHORS = 2 COLUMN V 3X3X1 2GA COLUMN STRESS =0.24 BRACING HORIZONTAL ^/ DIAGO 1 1/2X 1-1/2X 14GA 1 1/2X 1-1/ STRESS = 0 04 STRESS = BEAM V4-3/1 6X2-1 /2X1 4GA(BB3) MAX LOAD/LEVEL = 4,973 Ib BEAM IS O K SLAB & SOIL NAL V V '2 X 1 4 GA PUNCT STRESS = 0 22 0 08 BENDING STRESS =0 09 PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO OF.15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY_BOB S DATE.01-29-2001 LOADS & DISTRIBUTION :TYPE S/R LIVE LOAD PER SHELF = Wll = 3,000 Ib (BASED ON CLIENT SUPPLIED DATA) DEAD LOAD PER SHELF = Wdl = 200 Ib TOTAL LOAD PER FRAME = 3,200 Ib SEISMIC SHEAR BASED ON SECTION 1630.2.1 OF THE 1997 UBC WHERE V = ((2.5 x Ca x I) / R) x Wtotal Wtotal = (Wll + Wdl) x n n = # of shelves Seismic Zone = 4 Ca = 0.44 R(long) = 5.6 R(trans) = 4.4 LONGITUDIAL DIRECTION 1= 1 Soil Coef. = Sd Na = 1.0 Nv= 1.6 f M * 1 8 10" 8 t 3" 5" ' U Ib 2 3,000 Ib 1 / nrn C- 1 IT 421# Vlong = (2.5 x 0.44 x 1 )/(5.6) x W) / 1.4 449 Ib w/ working stress reduction Fi= VWhi/ZWh TRANSVERSE DIRECTION Vtrans = (2 5 x 0.44 x 1 )/(4.4) x W / 1.4 571 Ib w/ working stress reduction Fi= VWhi/ZWh lu= 96" 42" 42" n 35# t- A?"42'H 536# PROJECT, FOR NEXT PROTEIN CS GOODALE SHEET NO 8 OF.15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY_BOBS DATE.01-29-2001 LONGITUDINAL ANALYSIS "TYPE S/R THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE COLUMNS ASSUMED AT MID-HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR CLOSER TO THE BASE (OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT CARRY MOMENT) Vlong = 2 * Vcol = Vcol = F 1 = 211 Ib. F 2 = 14 Ib. 449 Ib 224 Ib.Beam toCol Conn BASE PROVIDE PARTIAL FIXITY SEE BASE PLATE SHT. Mbase = 6337 in Ib Mupper + Mlower = Mconn'R1 + Mconn'L' Mconn'R' = Mconn'L1 Mconn * 2 = Mupper + Mlower Mconn = [Mupper + Mlower]/2 RESULTING FORCES ON COLUMN SECTION AXIAL LOAD MOMENT Mconn 1 1600 12519 ODD<12 50 605 Mupper Jlf— B—7T SLAB MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO OF_15 CALCULATED BY_BOBS.DATE.01-29-2001 COLUMN ANALYSIS :TYPE S/R COLUMN IS ANALYZED PER AISI COLD-FORMED STEEL DESIGN MANUAL Pmax = 1,600 Ib Mmax = 12,520 m.lb. Kxlx/rx = 1 2 * 84 / 1 304 = 77 3 <- GOVERNS Kyly/ry = .8 * 42 / 1.08= 31.1 Cc = (2nA2E/Fy)A 5 = 1070 SINCE Kl/r <= Cc, Fa = 522Fy-[(kl/r*Fy)/1494]A2 = 1 9,407 psi fa = Pmax/Area = 1,749psi. fb = Mmax/Sx = 11,381 psi fa/Fa =0.09 <=.15 fa/Fa+fb/Fb <= 1.33 Fb = 6*Fy = 30,000 psi f b/Fb = 0.38 COMBINED STRESS = 0.47 ^ -I B SECTION PROPERTIES A =3" B = 3" C= 75" D = 0" E = 0" Wt =0# tl = 1046" t2 =0" Area= 915"A2 Ix = 1 65"M ly = 1 1"M Sx = 1 1 "A3 Sy = 73"*3 rx = 1 304" ry = 1 08" 88" +84" L 42" 42" Front View PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO 10 OF.15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY_BOB S.DATE.01-29-2001 BEAM ANALYSIS :TYPE S/R BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACITY TO STABLIZE THE SYSTEM, ALTHOUGH IT DOES NOT PROVIDE 100% FIXITY THUS, THE BEAMS WILL BE ANALYSED ASSUMING THEY HAVE PINNED ENDS FOR THE COMPUTATION OF BEAM TO COL MOMENT CAPACITY, THE PARTIAL FIXITY OF THE BEAM,(ASSUMED AT AN ARBITRARY 25% OF THE FIXED END MOMENT OR 2,000 in Ib WHICH EVER IS SMALLER) WILL BE ADDED : 2 5" — 1 75"— t= 0747 f ' in i >, \ 1 625" J_— »*— Sx = 1 119 in AS lx= 2430 in A4 lact = 96 0 in Imax = [1950 + 1200(Ml/M2)]b/Fy SINCE Ml/M2 = 1 0 Imax = 3150*b/Fy = 158 in SINCE Imax > lact Fb = 60Fy = 30,000 psi. MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON 4 1875' 1) BENDING CAPACITY M = Sx* Fb = w|A2/8 = 33570m.lb CAPACITY = 2(8*M/I) = 4973lb. 2) MAXIMUM ALLOWABLE DEFLECTION (L/180). A = 5w|A4/384EI CAPACITY = 2[(384EI)/(5*180*|A2)] = 6637lb. MAXIMUM STATIC LOAD PER LEVEL IS 4,973 Ib. ALLOWABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL Mstatic = w|A2/8 = LIVE LOAD*L/(2*8) Mallow(static) = Sx * Fb Mimpact = 1 125*Mstatic Mallow(seismic) = 1 33 * Sx * Fb Mseismic = Mconn (SEE LONG ANALYSIS) LEVEL Mstatic Mimpact Mallow Mseismic Mallow RESULT 11 zs Mstatic (static) (seismic) 1 18000 20250 33570 8562 44759 GOOD 2 18000 20250 33570 302 44759 GOOD PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO 11 OF 15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY.BOBS.DATE.01-29-2001 BEAM TO COLUMN CONNECTION Mconn= ( Mlower + Mupper )/2 + Mend CAPACITY OF CONNECTOR a) SHEAR CAPACITY OF 7/16" DIA STUD Area= 4375A2n/4= 150"A2 Fy = 50,000 psi Pmax = 3,000# b) BEARING ON COLUMN Abrg =t*D t= 0747mm = 5 * t Fu = 60,000 psi mm Pmax brg = Area * Fbeanng = 5t * 2 22 * Fu = 4,975# > 3,000# c) MOMENT CAPACITY OF BRACKET S bracket = 110"A3 Mcap = S * Fbendmg = 110* 66*Fy C = Mcap/ 75 = 1 67 P1 P1 = 798 Mcap = 0872 Fy = 4,360# > 3,000# SINCE PLUG GOVERNS P1=3,000# Mconn cap = P1 * 4 5 + P2 * 2 5 + P3 * 5 = 5 94 * 3,000# *1 33 = 23,778 "# Mconn 371"eff Mupper Mconn Mlower BEAM TO COLUM CONNECTION 1 5/8" A t = 7ga 1/2" C = P1 + P2 + P3 = P1 + (2 5/4 5)P1 + ( 5/4 5)P1 = 1 67 P1 Sbracket= 110"A3 PROJECT, FOR NEXT PROTEIN CS GOODALE SHEET NO 12 OF.15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY_BOB S.DATE.01-29-2001 TRANSVERSE ANALYSIS : BRACING :TYPE S/R IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND COMPRESSION IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE ON THE DIAGONAL MEMBER AS IT WILL GOVERN DIAGONAL BRACING • COMPRESSION MEMBER L diag. = [(L-6)A2+(D-2*Bcol)A2]A.5 = 509 Vdiag =Vtrans * Ldiag / D = 692# kl/rmin = [ 1 * 50 9 ] / 5292 = 96.20 Fa =.522Fy-[kl/r*Fy/1494]A2 = 15733 psi. fa/Fa =Vdiag/(Area*Fa) = 016 Dl= 50 9' D= 42" L= 42" DIAGONAL AND HORIZONTAL BRACING W- II Area= 2775 "*rmm= 5292 "t= 0598 " W= 1 5 " H= 1 5 " PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO 13 OF.15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY_BOB S.DATE.01-29-2001 OVERTURNING :TYPE S/R ANALYSIS OF OVERTURNING WILL BE BASED ON SECTION 222£ 7 1 OF THE 199"?-Uniform Building Code. FULLY LOADED TOTAL SHEAR = 571 Ib. Mot = Vtrans * ht * 1 15 = 571 *91 * 1.15 = 60057 in Ib Mst = Z(Wp+ 85wDL) * d/2 = ( 3000+ 85 * 200) * 42/2 = 66570 m.lb Puphft = 1 (Mot - Mst)/d Puplift <= 0 NO UPLIFT r42" 42 42 TOP SHELF LOADED SHEAR = 17lb. Mot = Vtop*h * 1.15 = 1 7 * 174 * 1 15 = 3573 in Ib Mst = (Wp+wDL) * d/2 = ( 0+ 85 * 200) * 42/2 = 3570 in Ib P uplift = 1(Mot-Mst)/d = 0 Ib <- CRITICAL fc 42"- 35# 536# USE 2 ea 1/2 x 3-1/2 MIN. EMBED. ANCHOR CAPACITY OF 1/2 x 3-1/2 = 875 Ib PULLOUT & 1 840 Ib SHEAR COMBINED STRESS1 = 0 / 1750 + 285 / 3680 = 0 08 COMBINED STRESS2 = 0 / 1750 + 8 / 3680 = 0.00 SEIZMIC PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO 14 OF. MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 CALCULATED BY BOBS DATE.01-29-2001 BASE PLATE TYPE S/R BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY) THERE ARE 3 CRITERIA IN DETERMINING Mb THEY ARE 1) MOMENT CAPACITY OF THE BASE PLATE, 2) MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3) Vh/2 (FULL FIXITY) Mb IS THE SMALLEST VALUE OBTAINED FROM THE 3 CRITERIA ABOVE Pcol = 1 600 Ib. B = 8 in. Mb = 6337 in Ib. D = 5 in b = 3 in. P/A = Pcol/(D*B) = 40 psi. M/S = Mb/((D*BA2)/6) = 11 8.8 psi. f b2 = 2b/B*fb = 74 26 psi fbl = fb-fb2 = 44.56 psi. Mbase = wbl *2/2 = bl *2/2[ fa + fbl + 67fb2] Mbase = 419.0 in Ib Sbase = 1*tA2/6 = 0 0234 in A 3 Fbase = .75Fy * 1 33 = 36000 psi f b/Fb = Mbase/(Sbase*Fbase) = .49 ANCHOR TENSION t = .375 in bl = 2.5 in. rfti Pcol bl B IA 1 / / fa fb I fbl T*d2=[Mbase- Pcol*b/2] T = Mbase/d2 - Pcol*b/2d2 T = 874 Ib. Pcol PROJECT. FOR NEXT PROTEIN CS GOODALE SHEET NO 15 MATERIAL HANDLING ENGINEERING TEL (909)869-0989 • FAX (909)869-0981 161 ATLANTIC STREET • POMONA • CA 91 768 OF.15 CALCULATED BY_BOBS DATE.01-29-2001 SLAB AND SOIL "TYPE S/R THE SLAB WILL BE CHECKED FOR PUNCTURE STRESS IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED TO DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND WILL ACT AS A FOOTING (a) PUNCTURE Pmax = 1 4 DEAD LOAD + 1.7 LIVE LOAD Pmax = Fpunct = 2*sqrt(f c) Apunct = [(w+t/2)+(d+t/2)]*2*t fv/Fv = Pmax/(Apunct*Fpunct) 1 4*Pcol 4,671 Ib 89 4 psi. 180.0 029 1.7*(Mot/d) (b) SLAB TENSION Asoil = Pmax/(1 33 * fsoil) = 3.50 ft = 504 in A2 L = sqrt(Asoil) = 22.5 in B = sqrt(w*d) + t = 11 3 in. b = (L-B)/2 = 5 6 in Mconc = wbA2/2 = (1 33*fsoil*bA2)/(144*2) 1435m.lb. Scone = 1 *tA2/6 = 417 m.A3 Fconc = 50 *sqrt(fc) = 201.25 psi. fb/Fb = Mconc/(Sconc*Fconc) = 0.17 ' b,' B T t ^ { JL, ' BASE PLATE w = 8 in. d = 5 in CONCRETE t = 5 in f'c = 2000 psi. SOIL f s = 1000 psf. PCR01048 2283 COSMOS CT CBADNEXT PROTEINSRACKS SFfeWN ON ORIGINAL T I PLANSPCRLot# HAWKINS STEVEcov*3A J \ Jc it) V 0 r * * J 0J i J j- 3 ^ 1 ri, o V. O-1 PA \