Loading...
HomeMy WebLinkAbout2283 COSMOS CT; ; CB021966; Permit03-17-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB021966 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2283 COSMOS CT CBAD Tl Sub Type 2130504300 Lot# $109,770 00 Construction Type Reference # NEXTPROTEINS INTERNATIONAL Tl - OFFICE 3,659 SF COMM 0 NEW Applicant HAWKINS DAVID 1025 F STREET SAN DIEGO CA 92101 619-232-770 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* Owner GERRY REVOCABLE LIVING TRUST 08-06-96 2033 SHIPWAY LN NEWPORT BEACH CA 92660 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee Green Bldg Stands (SB1473) Fee $577 36 Meter Size $0 00 Add'l Reel Water Con Fee $375 28 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $2305 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $1,207 36 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees •" HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $1,08443 $1,001 01 $000 $000 $000 $000 $2,678 00 $000 $000 99 $6,946 49 Total Fees $6,946 49 Total Payments To Date $375 28 Balance Due $6,571 21 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION.i^ CI>Y OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad CA 92008 PLAN CHECK NO EST VAL Plan Ck Deposit Validated By Date 1 PROJECT INFORMATION address)Address (includeBldg/Suite_#)-AltrOPr tiullrtlK* Lot No Subdivision Name/Number Phase No Total # of units isessor s Parcel #A&? Existirfg Use Descnption of Work SQ FT # of Stories Proposed Use 07/01/02 0002 01 02 "# of Bedrooms irjlQfJofeEithrooms 3?5 = 28 |2 CONTACT PERSON (if different from applicant^ Name Address City State/Zip Telephone #Fax# |3 APPLICANT Q Contractor D Agent for Contractor! ' D Owner Agent for Owner Name Address State/Zip Telephone # IS.CONTRACTOR - COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter improve, demolish or repair any structure, prior to its issuance, Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City'State/Zip City Business License #. Telephone # Designer Name State License # Address City State/Zip1 Telephone # |6 WORKER'S COMPENSATION Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations D I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued I have and will maintain workers compensation, as required by Section 3700 of the labor Code for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are • Insurance Company ^T' £-QtAP, (AJ^^U^ P Policy No ^.2_'_^l£!r__^.^ Expiration Vate,__j_i_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to cnmrnal penalties and civil fines up to one hiujfired thotj dollars($100,000), in addition to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees SIGNATURE DATE. OWNER-BUILDER DECLARATION J:LI hereby affirm that I am exempt from the Contractor's License Law for the following reason D I as owner of the property or my employees with wages as their sole compensation will d the work and the struc^nJIs Jbt^ntet^jecl or offered for sale (Sec 7044, Business and Professions Code The Contractors License Law does not apply to an owner of property who builds JrVnprjMis tlfeg$i and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If .Awever^^ _bwiljing g^r improvement is sold within one year of completion the owner-builder will have the burden of proving that he did not build or improve fortbajuyosgof sale) D I as owner of the property am exclusively contracting with licensed contractors to coiWudbiSprRecttSec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and coKracts for soSPf^rojects with contractors) licensed pursuant to the Contractor's License Law) \ \ 0 I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D YES Q NO 2 I (have/have not) signed an application for a building permit for the proposed work " 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) ( * 4 I plan to provide portionsgf.the work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad CA 92008 Page 2 of 2 [COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous matenals registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act' E YES Ij^'NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES ^3^NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES "f^ NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT CONSTRUCTION LENDING AGENCY|8 JL I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code) LENDER S NAME LENDER'S ADDRESS APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID*CITY IN CONSEQUENCE Of THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the building Official under Ink provisions of this Code shall expire by limitation and become null and void if the building 01 work authorized by such permit is not commenced/wrttmv380 days^roirkfliehlate of such permit or if the building or work authonzed by such permit is suspended or abandoned at any time after the work is commenced for a period of 180Wjys (SectiorNfts 4 4 Unjform Building Code) APPLICANTS SIGNATURE DATE 04/28/2003 HAWKINS DAVID 1025 F STREET SAN DIEGO CA92101 Re Application Date 07/01/2002 0 00 00 Plan Check # CB021966 Address 2283 COSMOS CT Expiration Date 07/01/2003 0 00 00 Permit Type Tl Description NEXTPROTEINS INTERNATIONAL Tl-OFFICE 3,659 SF You applied to have your plans checked on the date noted above To date, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee " In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department Project Abandoned - I will pick up plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2718 Raenette Abbey Building Department EsGil Corporation In (Partnership with government for 'BuiCding Safety DATE July 11,2O02 a(JURIS JURISDICTION Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO 02-1966 SET I PROJECT ADDRESS 2283 Cosmos Court PROJECT NAME Office Addition(T.L) for Next Protein The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Hawkins & Hawkins Architects 1025 F St, San Diego, CA 92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted David Hawkins Telephone # (619) 232-7700' Date contacted } In/oz (by l*_ ) Fax # 7770 Mail >—"Telephone ^ Fax-''' In Person REMARKS By Bert Domingo Enclosures Esgil Corporation D GA D MB Q EJ D PC 7/2/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576 Carlsbad O2-1966 July 11, 2002 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 02-1966 OCCUPANCY B/S2? TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED July 11, 2002 JURISDICTION Carlsbad USE Office/Warehouse ACTUAL AREA 3659 SQ FT STORIES TWO HEIGHT OCCUPANT LOAD DATE PLANS RECEIVED BY ESGIL CORPORATION 7/2/02 PLAN REVIEWER Bert Domingo FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot Carlsbad 02-1966 July 11,2002 . GENERAL 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete • PLANS 2 All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation Please include the California license number, seal, date of license expiration and the date the plans are signed Business and Professions Code 3 Provide a Building Code Data Legend on the Title Sheet Include the following code information for each building proposed * Justification to exceed allowable area in Table 5-B (if applicable) 4 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building ofiicial for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form • BUILDING AREA 5 When a building has more than one occupancy, the area shall be such that the sum of the ratios of the actual area divided by the allowable area for each occupancy shall not exceed one Section 504 3 Please see item 3 above Carlsbad 02-1966 July 11, 2002 • EXITS 6 Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) Show in this analysis the occupant load of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths 7 Please show the occupant load of the existing mixing room 8 Exits shall not pass through kitchens, store rooms, or spaces used for similar purposes Section 1004 2 2 9 Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served Section 1004 2 4 One exit door of the required on the 2nd floor exit into the lobby area and the other exit thru the other stairs but continue on the hallway leading to the same lobby • STAIRWAYS 10 Stairway handrails should not project more than 3-1/2 inches into the required width Trim and stringers may not project more than 1-1/2 inches Section 1003332 11 Enclosed usable space under interior or exterior stairways should be protected on the enclosed side as required for one-hour fire-resistive construction Show 2 x @ 16" o c nailers Section 1003 339 12 Vertical distances between stairway landings are limited to 12 feet Section 1003335 13 Handrails (Section 1003 336) a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous b) Ends of handrails shall be returned or shall have rounded terminations or bends • EXIT SIGNS 14 Exit signs are required whenever two exits are required Show all required exit sign locations Section 1003 282 15 If exit signs are required, provide the following notes on the plans, per Section 1003282 a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign b) Exit signs shall be readily visible from any direction of approach Carlsbad O2-1966 July 11, 2002 16 Show two sources of power for the lamps at exit signs Section 1003 2 8 5 17 Show that exits are lighted with at least one foot candle at floor level Section 1003292 • MISCELLANEOUS LIFE/SAFETY 18 Guardrails (Section 509 1) a) Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-B Please submit calculations b) Openings between railings shall be less than 4" The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6" • TITLE 24 DISABLED ACCESS 19 Provide notes and details on the plans to show compliance with the enclosed Disabled Access Review List Disabled access requirements may be more restrictive than the UBC • FOUNDATION 20 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 21 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans (when required by the soil report) 22 If the soils engineer would recommend that he/she review the foundation excavations, Please note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations comply with the intent of the soils report " • ADDITIONAL STRUCTURAL 23 Please show the detail 1/S7 as referenced on line 3 6 shown on S-3 24 Foundation will be checked when the soils report is submitted 25 Please submit calculations for the drag system along line C Carlsbad O2-1966 July 11, 2OO2 . ADDITIONAL 26 Please show 96 NEC 27 The warehouse could be S1 28 All the enclosures of the lobby 101 and 201 except the exterior walls should be one hour rated walls Any opening thru such walls should be 20 minute rating 29 The enclosure for the 1st level stairs at the grid line 1 is one hour rated but not on the 2nd level Please clarify 30 Is the existing building sprinkled? 31 The completed and signed ENV-1and MECH-1 forms must be imprinted on the plans • CARLSBAD SPECIAL CODE REQUIREMENTS 32 All new residential buildings, including additions, require a soils report An update letter is required if the report is more than 3 years old If a room addition is less than 1000 sq ft in area and only one story, then a soils report is not required Under this condition, Esgil staff should advise the City (upon final transmittal) to place their "soils notice" stamp on the plans To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Q Yes a No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you Carlsbad O2-1966 July 11, 2002 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No O2-1966 Job Address or Legal Description 2283 Cosmos Court Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit wntten reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad O2-1966 July 11, 2OO2 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION. PLAN CHECK NUMBER OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer a/Architect 6 Seal & Signature Heie Signed 1. List of work requiring special inspection Q Soils Compliance Prior to Foundation Inspection Q Field Welding Q Structural Concrete Over 2500 PSI Q H|gh Strength Bolting Q Prestressed Concrete D Expansion/Epoxy Anchors Q Structural Masonry n Sprayed-On Fireproofing Q Designer Specified Q Other 2 Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above1 A B C 3 Duties of the special inspectors for the work listed above* A B C. Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site Carlsbad O2-1966 July 11, 2002 DEPARTMENT OF STATE ARCHITECT TITLE 24 DISABLED ACCESS REQUIREMENTS • REMODELS. ADDITIONS AND REPAIRS When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) The area of specific alteration, repair or addition must comply as "new" construction b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features d) Existing drinking fountains (if any) must be shown to comply with all accessibility features e) Existing public telephones (if any) must be shown to comply with all accessibility features Carlsbad 02-1966 July 11, 2002 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Bert Domingo BUILDING ADDRESS 2283 Cosmos Court PLAN CHECK NO 02-1966 DATE July 11, 2002 BUILDING OCCUPANCY B/S1 TYPE OF CONSTRUCTION VN BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq Ft ) cb 1QQ1 1 IRr Ri iilrlinn Pprmif FPP ^- Valuation Multiplier By Ordinance Reg Mod VALUE ($) 109,770 109,770 $577 36 1991 UBC Plan Check Fee Type of Review Repetitive Fee Repeats Complete Review D Other fj Structural Only D Hourly Hour Esgil Plan Review Fee Comments Value was taken from the city's transmittal dated 7/1/02 $375 28 $323.32 Sheet 1 of 1 macvalue doc City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST DATE BUILDING ADDRESS PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date By FOR OFFICIAL USE ONLY G AUTHRIZATION TO ISSUE BUILDING PERMIT Date - D n c n LJ ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet Name ENGINEERING DEPT CONTACT PERSON Karen Saul City of Carlsbad Address 1635 Faraday Avenue, Carlsbad, CA 92008 Phone (760) 602-2775 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract 0 3RD BUILDING PLANCHECK CHECKLIST SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show North Arrow Right-of-Way Width & Adjacent Streets Existing & Proposed Structures ^ Driveway widths Existing Street Improvements $f Existing or proposed sewer lateral Property Lines /$- Existing or proposed water service Easements $r Existing or proposed irrigation service D D 2 Show on site plan Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " Existing & Proposed Slopes and Topography fa Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet /(, Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION H \WORDiDOCSlCHKLST\Building Plartcheck CWst Form (Generic) doc BUILDING PLANCHECK CHECKLIST ST ND2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE D EH 4a Project does not comply with the following Engineering Conditions of approval for Project No __ CH D EH 4b All conditions are in compliance Date DEDICATION REQUIREMENTS L3 D CH 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15.000. pursuant to Carlsbad 1r Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Yz" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS CD CD 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the H \WORD\DOCS\CHKLST\BuiHing Plancheck Cklst Form (RIDDLE HARVEY 7 12 00) doc .. ST BUILDING PLANCHECK CHECKLIST checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate secunties posted and fees paid prior to issuance of building permit Improvement Plans signed by Date D D D 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property tille report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows 6c Enclosed please find your Future Improvement Agreement Please return agreement signed and notarized to the Engineering Department Future Improvement Agreement completed by Date G D 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code G G G 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities (cut, fill import, export) G O G 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date G Q 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) H \WOHD\DOCS\CHKlST\BiJilding Plancheck Cklst Form (Genera 7 14-00) doc BUILDING PLANCHECK CHECKLIST 7d No Grading Permit required 7e lf grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D D D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for n D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date n 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first ] 11 yQ Required fees are attached 'Q No fees required WATER METER REVIEW HH D D 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service H \WORD\DOCS\CHKLST\BuiHing Planctieck Cklst Foim (Genetic) doc 1ST •>ND oRD ODD 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water H \WORDlDOCS\CHKLST\Buikicng Plancheck Cklsl Form (Generic) doc Rev 7/14/00 BUILDING PLANCHECK CHECKLIST «ST pND oRD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future Zl D D 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this D D D 13 Additional Comments: H \WORD\DOCS\CHKLST\Building Plandieck CWst Forni (Generic) doc ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal Address <3^-%3> (j&'&mc& C^~- Bldg Permit No C£?O3- ~~tQl Co (jj Prepared by (L.SS EDU CALCULATIONS- Tvoes of Use ^AVc- (S(^f Types of Use APT CALCULATIONS Types of Use ^A/j'< Types of Use FEES REQUIRED Date ^ / ( o/<P — Checked by List types and square footages for all uses •<^<L Sa Ft /Units 5, 10^ Sa Ft /Units List types and square footages for all uses ix<_e_ Sa Ft /Units ^ US'! Sa Ft /Units Date EDU's EDU's ADT's i ADT's / 3 WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) PARK-IN-LIEU FEE PARK AREA & # FEE/UNIT _ X NO UNITS _ =$_ TRAFFIC IMPACT FEE _ , ADT's/UNITS Sj^ffX x FEE/ADT 36 =$ £/ V°$ • /7 BRIDGE AND THOROUGHFARE FEE (DIST #1 X. DIST #2 _ DIST #3 _ ) ADT's/UNITS £if'8& X FEE/ADT FACILITIES MANAGEMENT FEE ZONE / . </& L f*j / K UNIT/SQ FT 3,<** I X FEE/SQ FT /UNIT 5 SEWER FEE / ^ 'EDU's / • ^ X FEE/EDU _oj BENEFIT AREA X^ EDU's X FEE/EDU =$_ 6 SEWER LATERAL ($2,500) =$_ 7 DRAINAGE FEES PLDA HIGH /LOW ACRES X FEE/AC =$ / 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION 1 of 2 F \FEE CALCULATION WORKSHEET doc Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $ *NOTE This calculation sheet is NOT a complete list of all fees which may be due Dedications and Improvements may also be required with Building Permits 2 of 2 F \FEE CALCULATION WORKSHEET doc R=v 7/14/00 /KM ~ $ -"73 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No Address CJ~ Planner Christer Westman APN Phone (760) 602-4614 Type of Project & Use Zoning ^\. General Plan Net Project Density /_ Facilities Management Zone DU/AC CFD (m/out) #_ Circle One of participation Remaining net dev acres (For non-residential development Type of land used created by this permit ) Legend Item Complete Environmental Review Required DATE OF COMPLETION Item Incomplete - Needs your action YES NO V" TYPE Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES CA Coastal Commission Authority7 YES_NO If California Coastal Commission Authority Contact them at - 3111 Cammo Del Rio North, Suite 200, San Diego CA 92108-1 725, (619) 521-8036 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # YES NO Follow-Up Actions 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed H \ADMIN\COUNTER\BldgPlnchkRevChklst Inclusionary Housing Fee required YES NO V* (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) ' Data Entry Completed? YES NO / (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Vlousing Fees, Construct Housing Y/N, Enter Fee, UPDATE1) Site Plan- 1 Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines 2 Provide legal description of property and assessor's parcel number Zoning. ]T ^J 1 Setbacks Front Interior Side Street Side Rear N 2 Accessory structure Front Interior Side Street Side Rear Structure separation 3 Lot Coverage Required Required Required Required setbacks Required Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown 4 Height Required 5 Parking Spaces Required Guest Spaces Required Additional Comments Shown Shown Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRevChklst Carlsbad. Fire Department 021966 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report Q?/16/2002 Fire Prevention (760) 602-4660 BuildingJ'lan Reviewed by Name Address City, State Hawkins & Hawkins 1025'F'Street San Diego CA 92101 Plan Checker Job Name Job Address Next Proteins Job# 021966 Bldg # CB021966 2283 Cosmos Ct Ste or Bldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards LJ Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job# 1st 2nd 3rd 021966 FDFile# Other Ag^nny IH Ju"l-15-O2 O1:36P Hawkins & Hawkins Archite P.O3 City of Carlsbad Plumbing - Electrical - Mecfianical Worksheet Project Address Permit No, Questions below refer to work being done for this permit only Plumbing * Number of new or relocated fixtures, traps, or floor drains? * New building sewer line? * Number of roof drains? * Install/alter water line? » Mumber o* water heaters? * Number of hose bibs? * Gas piping system - * Number of new or relocated gas outlets * New water meter - Potable. Electrical * Number of new panels or subpanels? cO Yes Yes No X ^'X/^T No W £> & Install __£> Repair £> No of Irrigation Size Size of New Service 1 Size« Single Phase * Three Phase * Three Phase - 480 * Remodel (relocate existing outlets/switches or add outlets/switches Mechanical * Number of furnaces, A/C, or heat pumps?' * Number of fireplaces? • Number of exhaust fans? • Number of exhaust hoods? * Number of boilers or compressors' • New or relocated duct work? Number of amperes l\f n Number of amperes rO t\_ Number of amperes M/ n Yes )( No Number of HP? Yes X No BEFORE THE PERMIT CAN BE FEE'D OUT THIS FORM NEEDS TO BE RETURNED TO THE BUILDING DEPARTMENT - FAX NUMBER (760) 602-8558 .A. -*• ZED Structural Engineers 7920 MiramarRd #127 San Diego Ca 92126-4206 TEL (858) 549-6996 FAX (858) 549-2121 SCALE SHEET NO OF CALCULATED BY. JOB DATE NEXT PROTEINS T.I. CONTENTS : DESIGN LOADS Dl FLOOR FRAMING FF1 COLUMN DESIGN Cl FOOTINGS Fl LATERAL ANALYSIS LI GOVERNING CODES : --> D4 — > FF8 -> Cl --> Fl — > L12 UNIFORM BUILDING CODE 1997 AMERICAN CONCRETE INSTITUTE (318-95) 1995 AMERICAN INSTITUTE OF STEEL CONSTRUCTORS MANUAL ... 9TH EDITION DESIGN CRITEREA 1- SEISMIC ZONE : 4 2- WIND EXPOSURE : C 3- MAXIMUM ALLOWABLE SOIL PRESSURE : 3,000 PSF 4- MATERIALS & DESIGN STRESSES (U.O.N) : - FRAMING LUMBER - BOLTED CONNECTIONS - STRUCTURAL STEEL - REINFORCING STEEL - CONCRETE 5- BASIC LIVE LOADS : ROOF FLOORS CORRIDORS OFFICE DOUGLAS-FIR LARCH (NORTH) STEEL FRAMING : A325-N WOOD FRAMING : A307 A572 (FY = 50 KSI) ASTM A53, GRADE B (Fy=36 KSI)PIPES ASTM A500, GRADE B (Fy=46 KSI)TUBES #4 & SMALLER ASTM 615 (FY = 40 KSI) #5 & LARGER ASTM 615 (FY = 60 KSI) FOOTINGS : F'C = 3,000 PSI : 20 PSF :100 PSF : 50 PSF -*~ ZED Structural Engineers 7920 Miramar Rd #127 San Diego Ca 92126-4206 TEL (858) 549-6996 FAX (858) 549-2121 SCALE SHEET NO OF CALCULATED BY. JOB DATE LOAD COMBINATIONS : UBC SECTION 1612.3.2 WILL BE BASED ON ALLOWABLE STRESS DESIGN USING THE 33% INCREASE DESIGN LOADS : ( CONC TILT-UP BLDG W/ MEZZANINE ) A- VERTICAL GRAVITY LOADS (PSF) : 1- ROOF DEAD LOAD : ( NEARLY FLAT ROOF ) GRAVEL 4.0 3-PLY FELT 1.5 PLYWOOD 1.5 INSULATION 0.5 2x6 @ 24" SUB-PURLINS 1.0 PURLINS @ 8' 0/C 2.5 GLB @ 48' 0/C 1.5 CEILING 2.5 SPRINKLER 1.0 D.L.= 16.0 2- ROOF LIVE LOAD : 20 PSF REDUCIBLE 3- TYPICAL EXTERIOR CONC WALL PANELS: 7V THK = 94 PSF 9V THK _116 PSF 4- INTERIOR PARTITIONS : 20 PSF 5- MEZZANINE DEAD LOAD (PSF) : FLOORING 1.2 1.5 " LT WT CONC TOPPING 14.0 3/4" PLYD 2.5 TRUSS JOIST FLOOR 3.0 CEILING 2.8 STEEL BM 1.0 MECHANICAL/ MISC 2.5 D.L.= 27.0 PSF 6- MEZZANINE LIVE LOAD (PSF) : OFFICE L.L. = 50 PSF CORRIDORS L.L. = 100 PSF -> USE OVERALL: 80 PSF +20 PSF PARTITIONS A. —" ZED Structural Engineer 7920 MiramarRd #127 San Diego Ca 92126-4206 TEL (858) 549-6996 FAX (858) 549-2121 SCALE SHEET NO OF CALCULATED BY. JOB DATE B- LATERAL LOADS (PSF) : (CONC TILIT-UP BLDG W/ MEZZANINE) 1- SEISMIC LOAD : BASIC SEISMIC LOAD V = (2.5 x Ca x I)/R x W EQUIV SEISMIC WT Z - .4 ZONE FOUR 1=1.0 STANDARD OCCUPANCY Ca : SEISMIC COEFFICIENT : SOIL PROFILE SD ==> Ca = 0.44 x Na Na : NEAR SOURCE FACTOR SEISMIC SOURCE TYPE "B" DISTANCE FROM SOURCE TYPE > 10 KM Na = 1.0 Ca = 0.44 x 1.0 = 0.44 R = 4.5 BRG SHEAR WALLS / STL BRACED FRAMES ==> YU = (2.5 x 0.44 x 1.0)/4.5 x W ==> V, = 0.244 X W ULTIMATE LEVEL THE ABOVE SEISMIC LOAD IS AT ULTIMATE/STRENGTH DESIGN LEVEL. THE SEISMIC LOAD AT WORKING STRESS LEVEL = E/1.4 ==> V - 0.175 X W SERVICE LEVEL 2- WIND LOAD : BASIC WIND PRESSURE P = CE X CQ X QS X I CE= 1.23 EXPOSURE C ; HEIGHT < 30 FT, CQ= 1.3 METHOD TWO ; HEIGHT < 40 FT, QS=12.6 PSF BASIC WIND SPEED = 70 MPH 1=1.0 STANDARD OCCUPANCY P = 20.1 PSF BY INSPECTION, SEISMIC LOAD GOVERNS DESIGN. 1127 8 MCCLELLAN 'PALOMAR AIRPORT ZCARISiAKT 5-- I •=•«•.. //^3 PIPIT a i- -,„ NICOLA,, £r <?'/'f '^S^ST 1 VERBENA a 5 \% y™CM£ 4 VESPER IN "- i-Wlnf, - n'o, i-nxA*'0 §.//™sf™j^^ i fi t AV^^^ 's^p. if ^j*^*: ---\ IKKK i- uii-p;^ to>:/ «« ^fl^l^^y^'^1 JSS!li! f^*^ £ -•-. -™^—iQaS^t"'15"! .^^SaJJ-OVa fffiil^ 4 /a'N "^ ^*§i?mVJp-l^^'f ^•" ;^ Jp"^ i rVir' ^^4r^iU?LIA AV g '"li^EWOlg!; 1 ^-1''> IGHTHOUSf1 '' jSft'*- ** ^f?1?;^-' ^'^— nn-._'' J'"*- \3> , _]n .Q) cl[./ !$%\L.X^ ^^ SLli ]M.LUii|\^ ^V^V^ (6RII'E7TfW KEI!^a. te^-<g'.'SVV<0 \ '•'C.T'CT f Vr^^s:^.: V^a .^* £ *- 1900 ft trtftfffffttfTttTT t t_i A-ZED Structural Engineers 7920 M.ramar Road, Suite 127 SHEET NO ~n^-L OF- San Diego, Ca 92126-4206 CALCULATED BY Tel (858) 549-6996 Fax (858) 549-2121 CHECKED BY DATE JOB I L. T- t> 17' T. TIE®/L65 Joist Load Tables/Floor (100%) Performance Plus® Web Material • Simple Span • Parallel TJI® Joist Allowable Uniform Load (plf) Glue-Nailed Floor Values shown are maximum allowable load capacities of the joists in pounds per lineal foot (plf) based on simple span, uniformly loaded conditions with web stiffener and bearing length criteria shown on page 3 2 (lower or higher load capacities may be possible with different criteria, use the TJ-Beam'" software program or contact yourTrus Joist MacMillan representative for assistance alues in gray ssfiatied areas may be increased 4% for repetitive member usage if the criteria on page 9 7 are met "Camber (2250' radius) is available for simple span applications only Contact yourTrus Joist MacMillan representative for availability For loading conditions not covered by these tables (eg concentrated loads), use the TJ-Beam'" software program or contact your Trus Joist MacMillan representative for assistance 74c REV 1/99 W TJI /L90 foist Load Tables/Floor ( 100%) Performance Plus® Web Material • Simple Span • Parallel TJI® Joist Allowable Uniform Load (plf) Glue-Nailed Floor 221 | 198 221 212 i 177 212 204 i 159 204 1 Values shown are maximum allowable load capacities of the joists in pounds per lineal foot (plf) based on simple span, uniformly loaded conditions with web stiffener and bearing length criteria shown on page 3 2 (lower or higher load capacities may be possible with different criteria, use the TJ-BearrT software program or contact yourTrus Joist MacMillan representative for assistance 2 Values in gray sttagaeg areas may be increased 4% for repetitive member usage if the criteria on page 9 7 are met 3 Camber (2250' radius) is available for simple span applications only Contact yourTrus Joist MacMillan representative for availability 4 For loading conditions not covered by these tables (eg concentrated loads), use the TJ-Beam"" software program or contact your Trus Joist MacMillan representative for assistance 76c REV 1/99 W A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY CHECKED BY JOB _OF_ .DATE DATE -02. -k. Ar =&A - n ~ -•> .use,Z2- .(-fa ~ 0- A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY_ CHECKED BY .OF. DATE DATE -2.) * ~C A -" 2,0 " .......... T) * y =. A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE. SHEET NO . CALCULATED BY CHECKED BY JOB .OF DATE DATE I zsr t- fir _- 5c? -7 V - A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE. SHEET NO . CALCULATED BY CHECKED BY JOB OF . DATE . DATE ( « 2SA*/. /2 I-1. Jk -w 1' "^•^ 2,1 = *, 7 A - .- 3fe? Title Dsgnr Description Date- Scope Multi-Span Steel Beam Page 7| General Information Description Fy - Yield Stress 50 00 ksi Spans Considered Continuous Over Supports Load Duration Factor 1 00 Span Information | Span Steel Shape End Fixity ft 2150 W14X30 Pin-Pin 1300 W14X30 Pin-Pin Loads | Dead Load Live Load Dead Load Live Load Start End Point #1 DL LL @X k/ft k/ft k/ft k/ft ft ft k k ft 010 016 056 096 19500 1 74 296 19500 010 016 Results | Mmax @ Cntr @x = Max @ Left End Max @ Right End fb Actual Fb Allowable k-ft ft k-ft k-ft psi psi 737 903 00 -695 21,1327 33,0000 Bending OK 00 1300 -695 00 __ —. ' _ 199322 m**rQfZ£!i£-&^ £€zt*^'&J~W' *—iA ^ ~ ^~~ 25,9137 ^""^ Bending OK Reactions & Deflections | Shear @ Left Shear @ Right Reactions DL @ Left LL @ Left Total @ Left DL @ Right LL @ Right Total @ Right Max Deflection @x = k k k k k k k k in ft 1620 2373 600 1019 1620 1144 1933 3077 -0647 1003 704 366 11 44 1933 3077 -1 33 -232 -366 0136 537 A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY CHECKED BY JOB OF_ DATE o . A-ZED Structural Engineers " ' ' 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858) 549-6996 Fax (858) 549-2121 A tfrf^fc '(*) -p*v? ?tP€>7 SCALE SHEET NO ~JF 1 OF CALCULATED BY \&tf DATE G(y ~2& -02- CHECKED BY DATE JOB #0?0rif ^ ^ ®,® f f Cot, tZ-"o , 's*-'* 12," 0<3O L - — •> /"7, o fe \/ A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY CHECKED BY_ JOB .OF. DATE €?<& DATE 7o / /•*/ ; C X LC&-K? z y- /o A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY CHECKED BY JOB _±Sfc__OF_ \Jfir& DATE DATE It- $ 0 37 r t> I~T£,* £7 -~ 37-0 . o 0ee> tins A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO .OF CALCULATED BY. CHECKED BY JOB. DATE DATE So o (A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY CHECKED BY JOB .OF. DATE DATE vfr 'ACS -7 - I I ~1 A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE. SHEET NO . CALCULATED BY. CHECKED BY JOB. .OF .DATE DATE oc* A- - ,£\S -9 ' 2-/n — wt -^ / c>7 T- - 2 . 8, fO r _- fob 2 z) * / 33 ? 72- - 0 -fe. A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE. SHEET NO . CALCULATED BY. CHECKED BY JOB -OF_ .DATE DATE CCf&Clc, 7 . Z 12.x 7 A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO CALCULATED BY CHECKED BY JOB #02.0 + ^ L, 7 .OF DATE^ .DATE TO 7*- :/% /4^ X>^- // -k'fc x > o - J2. «: ^ 2- - x o. <Z * o A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO . CALCULATED BY CHECKED BY JOB _OF_ .DATE DATE •2or//Z7---'k. 7 ( > 4- A-ZED Structural Engineers » ' ' • *•* 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858) 549-6996 Fax (858) 549-2121 SHEET NO CALCULATED BY CHECKED BY JOB 'b&Zo'S<J ^ ^ OF \J/ty& DATE d^7 *~ ^(o -t*T 2 DATE £e<s'o - /o £b rr\ f* 25,100 f l'! r? -- toj. z. v/ ;: HA-*. y-- /^k^ 7 /^ f -/ . tA-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE SHEET NO. CALCULATED BY CHECKED BY JOB ^ *~ >° OF _ DATE _ DATE 7z' ITI-fZtj v! - IHr . C, (061 J< (yf.Ce.k-- Orrr - . .A-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE, SHEET NO . CALCULATED BY CHECKED BY JOB .OF .DATE. DATE •FT f ' > V o (t . . tA-ZED Structural Engineers 7920 Miramar Road, Suite 127 San Diego, Ca 92126-4206 Tel (858)549-6996 Fax (858)549-2121 SCALE. SHEET NO OF CALCULATED BY CHECKED BY JOB DATE DATE " 2-6? ~£>2. .!.. A r^-l. h K : ^j u. - .0 ffb -- o. TITLE 24 REPORT Title 24 Report for: NEXT PROTEINS 2283 COSMOS COURT CARLSBAD, CA Project Designer: Report Prepared By: HADI MAHZARI ENERGY CONSULTING GROUP 8015 BALBOA AVENUE SAN DIEGO, CA 92111 (858) 268-0660 Job Number: Date: 6/14/02 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards This program developed by EnergySoft, LLC (415) 883-5900 SnergyP^o 3 1 By EnergySoft Job Number User Number 2984 H Z O O H §~n -g <o~n -n o> CO a a mw d o ; o C< P Ni< ? •N/ I3 1 H > ~n-0 3 ?°5s 2 0H r T3 O CO m -n S O O § Os^I^i§SS § s 9^ s J Iislllp m S^^Sgo2 i m 1: