HomeMy WebLinkAbout2288 Camino Robledo; ; CBR2018-0638; Permit(city of
Carlsbad
Residential Permit
Print Date: 09/11/2018 Permit No: CBR2018-0638
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
2288 Camino Robledo
BLDG-Residential
2552704300
$10,604.28
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Alteration Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Closed -Finaled
03/14/2018
05/08/2018
CRenf
Plan Check#:
Final
Inspection: 9/11/2018 12:23:23PM
Project Title:
Description: PULLIN: CONVERT EXISTING 228 SF GARAGE INTO A BEDROOM
Applicant: Owner:
SHANE JOST CONSTRUCTION
SHANE S JOST
TRUST PULLIN PAUL AND MONICA LIVING
TRUST 07-10-14
2426 Torrejon Pl
Carlsbad, CA 92009-8033
760-305-3675
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
2288 Camino Robledo
CARLSBAD, CA 92009
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $292.89 Total Payments To Date: $292.89
Contractor:
SHANE JOST CONSTRUCTION
2426 Torrejon Pl
Carlsbad, CA 92009-8033
760-305-3675
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
1635 Faraday Avenue, Carlsbad, CA 92D08-7314 I 760-6D2-2700 I 760-602-8560 f I www.carlsbadca.gov
$123.83
$86.68
$41.DO
$39.00
$1.00
$1.38
,.
• ( City of
Carlsbad
Building Permit Application
1635 Faraday Ave,, Carlsbad, CA 92008
Ph: 780-802-2719 Fax: 760-602-8558
email: bulldlng@carlsbadca.gov
www.carlsbadca.gov
Plan Ck. Deposit /I g<, .&E
JOB ADDRESS (! "'11111 A!_ D f?oj:, fcC>O z.z_g57
CT/PROJECT# LOT# PHASE# # OF UNITS
~08
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
~IST/.N I-tf-.t,.u, e-
EXISTING USE .5wwr <!Ac. f.,.
PROPOSED USE a EPtf!. o",,,,, GARAGE (SF)
ZIP '?2.0(> 4'
Date
SUITE#/SPACE#/UNIT# APN
;;, rzoo ~55
lrliATHROOMS TEN NT BUSINESS NAME
INTO t3 t:P~oo ,'1,f
DECKS (SF)
tv"v
FIREPLACE
YES0 # __ NO%
CITY STATE
t;A.qsB.+D C.+
p~/b -?S-.3 -7~7_.?IFAX
EMAIL
Z70 -<-/ 3 -00
CONSTR. TYPE OCC. GROUP
AIR CONDITIONING
YES ,0'"'°No D
ZIP
FIRE SPRINKLERS
YES O NO
'?Z=_e>__~-------'
(Sec. 7031.5 Business and P.rofessions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement Uiat he 1s licensed pursuant to the provisions of the Contractor's License Law fChapter 9, commending with Section 7000 of D1v1s1on 3 of the B.usmess and Professions Code} or fuat he 1s exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
c1v1I penalty of not more than five hundred dollars {$500)).
WORKERS" COMPENSATION
Workers' Compensalion Declaration: I hereby affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificale of consent to self-insure for workers' compensation as pro~ided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co Policy No. Expiration Date _______ _
This section need not be completed if the permit is for one hundred dollars {$100) or less.
~ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensaf coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, dama e r in Section 3706 of the Labor code, interest and attorney's fees.
,Ji$ CONTRACTOR SIGNATURE
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure 1s not intended or offered for sale (Se<;.,1(144, Business and Professions Code The Contractor's
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees prov!8"ef tfl~ t such improvements are not intended or offered for
sale If however the building or improvement 1s sold within one year of completion the owner builder will have the burden of proving that he did not build or I rove for the purpose of sale)
I as owner of the property, am exclusrvely contracting with licensed contractors to construct the proJect (Sec 7044 Business and Professions Code The Cont ctor s License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant lo the Contr~s License Law) I
I am exempt under Section Business and Professions Code for this reason ~ I
1 I personally plan to p~ov1de the maJor labor and materials for construcijon of the proposed property 1mpro~ement D Yes ~ No
2 ave I have not) signed an application for a building permit for the proposed work ~,
3 I ha ontracted with the following person (firm} to provide the proposed construction (include name address I phone I contractors license
4. I pic?n to ide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I a ess I phone I contractors' license number)
5. I will provide s of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type
,? / r""" ,f!5 PROPERTY OWNER SIGNATURE OAGENT DATE /"'J?
¥ -
:OMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY , -,
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? 0 Yes Cl No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes D No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the application and state that the above lnfonnation isoonectand that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representaWe of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILrrlES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of strucbJres over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the date of sudl permit or if the bui in or work auth ch pennit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
,,/1$ APPLICANT'S SIGNATURE DATE
, P9'MIT INSPECTION HISTORY RE~RT (CBR2018-0638) ' . '
\ ,, ~
Permit Typo:
Work Class:
Status:
Scheduled
Date
BLDG-Residential
Alteration
Closed -Finaled
Actual
Start Date Inspection Type
Application Date: 03/14/2018
Issue Date: 05/08/2018
Expiration Date: 02/12/2019
IVR Number: 10123
Inspection No. Inspection Status
Owner: TRUST PULLIN PAUL AND
MONICA LIVING TRUST 07-10-14
Subdivision: CARLSBAD TCT#88-03-02 UNIT#02
Addross: 2288 Camino Robledo
Carlsbad, CA 92009-9354
Primary Inspector Re inspection Complete
··--·--------------------
07/2612018 0712612018
08/09/2018 08/09/2018
08/13/2018 08/13/2018
08/16/2018 08/16/2018
09/11/2018 09/11/2018
BLDG-11
Foundation/Ftg/Pier
s (Rebar)
065112-2018
Checklist Item
BLDG-Building Deficiency
BLDG-84 Rough
Combo(14,24,34,44)
066486-2018
Checklist lte1n
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
BLDG-84 Rough
Combo(14,24,34,44)
066728-2018
Checklist ltern
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
BLDG-17 Interior
Lath/Drywall
067180-2018
BLDG-Ftnal
Inspection
Checklist Item
BLDG-Building Deficiency
069611-2018
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Passed Chris Renfro
COMMENTS
Inspected slab on grade for garage
conversion. OK to pour
Partral Pass Chris Renfro
COMMENTS
Need to spray foam through penetrations,
Around windows and bottom plate. OK to
insulate the one wall with no windows and
ceiling. Make exterior water tight.
Move smoke detector, needs to be 3 feet
from registers or tip a fan blade.
Passed Chris Renfro
COMMENTS
Passed Chris Renfro
COMMENTS
Passed Chris Renfro
COMMENTS
·----------·-----------·--·---September 11, 2018
Complete
Passed
Yes
Reinspection Incomplete
Passed
No
No
No
No
No
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 1 of 2
DATE: 05/07/18
JURISDICTION: City of Carlsbad
PLAN CHECK#.: cbR2018-0638
~ EsG1I
A SAFEbwlt Company
SET: III
PROJECT ADDRESS: 2288 Camino Robledo
~PP LI CANT
.f'" .URIS.
PROJECT NAME: Convert Garage to Living Space for Pullin Residence
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
IZJ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
Shane Jost
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Shane Jost///:'.:~ .:tnl.61r,J'elephone #: 760-305-3675/) 760i3S Z(;6?
Date contacted:Sh l1g (b~ Email: shanejost@gmail.com /]~fi\1$11,11 €.p@ C.Mfflt...Cbi..._
Mail Telephone Fax ~
REMARKS: Please have applicant sign sheets. Applicant picked up plans in person.
By: Javier Snider (RM) Enclosures:
EsGil
05/07/18
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
~ EsG1I
A SAFfbuilt Company
DATE: 04/13/18 0 APPLICANT
9(.,JURIS.
JURISDICTION: City of Carlsbad
PLAN CHECK#.: cbR2018-0638 SET: II
PROJECT ADDRESS: 2288 Camino Robledo
PROJECT NAME: Convert Garage to Living Space for Pullin Residence
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
D
Shane Jost
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Shane Jost Telephone#: 760-305-3675
Date contacted:~/i" (by:0 Email: shanesjost@gmail.com
e..Mail .,;:;:elephomllf l"l Fax In Person
REMARKS:
By: Javier Snider (RM)
EsGil
04/05/18
Enclosures:
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
___ ..,.
, , City of Carlsbad cbR2018-0638
04/13/18
NOTE: The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers of the items
are from the previous check list and may not necessarily be in sequence. II:!!
notes in bold font are current.
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. All sheets of plans to once again be signed by the person responsible for their
preparation on re-submittal. (California Business and Professions Code).
3. Show locations of permanently wired smoke alarms with battery backup, per
Section R314: Show all existing and new.
a. Inside each bedroom.
b. Outside each separate sleeping area in the immediate vicinity of the bedrooms.
NOTE: When more than one smoke alarm is required to be installed, the alarm
devices shall be interconnected in such a manner that the actuation of one alarm
will activate all of the alarms in the unit.
4. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space, or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.8.1. Note all smoke alarms will
be interconnected.
~ · • City of Carlsbad cbR2018-0638
04/13/18
5. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315: Show new
and existing.
a. Outside each separate sleeping area in the immediate vicinity of the bedrooms.
NOTE: When more than one carbon monoxide alarm is required to be installed,
the alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit. Note all CO alarms will be
interconnected.
6. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
7. Provide headers for the new windows to be installed in the "room
conversion sheet".
8. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406 Please clearly show complete note.
a. Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms,
dining, halls, etc. Please clearly note ALL outlets will be arc-fault protected.
, ~ City of Carlsbad cbR2018-0638
04/13/18
MISCELLANEOUS
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc. Please provide correction response to avoid any
additional undo corrections and delays.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes CJ No CJ
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Javier Snider (RM)
at EsGil Corporation. Thank you.
DATE: Mar 27, 2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: cbR2018-0638
../. EsG1I
A SAFEbui\t Coinpany
SETI
PROJECT ADDRESS: 2288 Camino Robledo
D APPLICANT
~ JURIS.
PROJECT NAME: Convert Garage to Living Space for Pullin Residence
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Shane Jost D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Shane Jost Telephone#: 760-305-3675
Date contacte z.'1 f 18' (by:--M Email: shanesjost@gmail.com
~ail Telephone
REMARKS:
By: Rich Moreno
EsGil
Fax In Person
Enclosures:
Mar 19, 2018
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad cbR2018-0638
Mar 27, 2018
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: cbR2018-0638 JURISDICTION: City of Carlsbad
PROJECT ADDRESS: 2288 Camino Robledo
FLOOR AREA:
Remodel: 228 sq-ft
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: Mar 14, 2018
DATE INITIAL PLAN REVIEW
COMPLETED: Mar 27, 2018
FOREWORD (PLEASE READ):
STORIES: no change
HEIGHT: no change
DATE PLANS RECEIVED BY
ESGIL CORPORATION: Mar 19, 2018
PLAN REVIEWER: Rich Moreno
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad cbR2018-0638
Mar 27, 2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2018-0638
PREPARED BY: Rich Moreno DATE: Mar 27, 2018
BUILDING ADDRESS: 2288 Camino Robledo
BUILDING OCCUPANCY:
BUILDING AREA
PORTION ( Sq. Ft.)
Remodel 228
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
1997 UBC Building Permit Fee
1997 USC Plan Check Fee ... , _:__J
Valuation
Multiplier
citv est
By Ordinance
Type of Review: 0 Complete Review
D Repetitive Fee
-··-;; Repeats
___ I
Comments:
D Other
D Hourly
EsGII Fee
Reg. VALUE ($)
Mod.
D Structural Only
1-------11 Hr. @ *
10,604
10,604
$123.461
sso.2sj
$70.37j
Sheet 1 of 1
City of Carlsbad cbR2018-0638
Mar 27, 2018
• PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. All sheets of plans to once again be signed by the person responsible for their
preparation on re-submittal. (California Business and Professions Code).
3. Show locations of permanently wired smoke alarms with battery backup, per
Section R314:
a) Inside each bedroom.
b) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
• NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
4. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space, or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.8.1.
City of Carlsbad cbR2018-0638
Mar 27, 2018
5. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315:
a) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
• NOTE: When more than one carbon monoxide alarm is required to be
installed, the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
6. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
7. Sleeping rooms shall have a window or exterior door for emergency escape.
Section R310.
a) Windows must have an openable area of at least 5. 7 square feet, with the
minimum openable width 20" and the minimum openable height 24".
b) The bottom of the clear opening shall not exceed 44" above the floor.
Do not measure to the window sill. This generally applies to windows that
have a height of 3' or less. See the figure below to see the correct
method of measurement.
City of Carlsbad cbR2018-0638
Mar 27, 2018
8. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
Residential Energy Lighting Requirements: ES 150.0(k)
9. All installed luminaires shall be high-efficacy in accordance with ES TABLE
150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in
enclosed luminaires. ES 150.0(k)
1 O. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be
equipped with a standard medium base screw shell lamp holder. ES 150.0(k)
11. SFD outdoor lighting fixtures that are attached to a building are required to be
high efficacy, be manually on/off switch controlled, and have both motion sensor
and photocell control. See ES 150.0(k) 3 for additional control options.
• MISCELLANEOUS
12. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
13. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes CJ No CJ
14. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Rich Moreno at
EsGil Corporation. Thank you.