Loading...
HomeMy WebLinkAbout2288 Camino Robledo; ; CBR2018-0638; Permit(city of Carlsbad Residential Permit Print Date: 09/11/2018 Permit No: CBR2018-0638 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 2288 Camino Robledo BLDG-Residential 2552704300 $10,604.28 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Alteration Status: Applied: Issued: Permit Finaled: Inspector: Closed -Finaled 03/14/2018 05/08/2018 CRenf Plan Check#: Final Inspection: 9/11/2018 12:23:23PM Project Title: Description: PULLIN: CONVERT EXISTING 228 SF GARAGE INTO A BEDROOM Applicant: Owner: SHANE JOST CONSTRUCTION SHANE S JOST TRUST PULLIN PAUL AND MONICA LIVING TRUST 07-10-14 2426 Torrejon Pl Carlsbad, CA 92009-8033 760-305-3675 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) 2288 Camino Robledo CARLSBAD, CA 92009 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $292.89 Total Payments To Date: $292.89 Contractor: SHANE JOST CONSTRUCTION 2426 Torrejon Pl Carlsbad, CA 92009-8033 760-305-3675 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 1635 Faraday Avenue, Carlsbad, CA 92D08-7314 I 760-6D2-2700 I 760-602-8560 f I www.carlsbadca.gov $123.83 $86.68 $41.DO $39.00 $1.00 $1.38 ,. • ( City of Carlsbad Building Permit Application 1635 Faraday Ave,, Carlsbad, CA 92008 Ph: 780-802-2719 Fax: 760-602-8558 email: bulldlng@carlsbadca.gov www.carlsbadca.gov Plan Ck. Deposit /I g<, .&E JOB ADDRESS (! "'11111 A!_ D f?oj:, fcC>O z.z_g57 CT/PROJECT# LOT# PHASE# # OF UNITS ~08 DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ~IST/.N I-tf-.t,.u, e- EXISTING USE .5wwr <!Ac. f.,. PROPOSED USE a EPtf!. o",,,,, GARAGE (SF) ZIP '?2.0(> 4' Date SUITE#/SPACE#/UNIT# APN ;;, rzoo ~55 lrliATHROOMS TEN NT BUSINESS NAME INTO t3 t:P~oo ,'1,f DECKS (SF) tv"v FIREPLACE YES0 # __ NO% CITY STATE t;A.qsB.+D C.+ p~/b -?S-.3 -7~7_.?IFAX EMAIL Z70 -<-/ 3 -00 CONSTR. TYPE OCC. GROUP AIR CONDITIONING YES ,0'"'°No D ZIP FIRE SPRINKLERS YES O NO '?Z=_e>__~-------' (Sec. 7031.5 Business and P.rofessions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement Uiat he 1s licensed pursuant to the provisions of the Contractor's License Law fChapter 9, commending with Section 7000 of D1v1s1on 3 of the B.usmess and Professions Code} or fuat he 1s exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a c1v1I penalty of not more than five hundred dollars {$500)). WORKERS" COMPENSATION Workers' Compensalion Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificale of consent to self-insure for workers' compensation as pro~ided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co Policy No. Expiration Date _______ _ This section need not be completed if the permit is for one hundred dollars {$100) or less. ~ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensaf coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, dama e r in Section 3706 of the Labor code, interest and attorney's fees. ,Ji$ CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure 1s not intended or offered for sale (Se<;.,1(144, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees prov!8"ef tfl~ t such improvements are not intended or offered for sale If however the building or improvement 1s sold within one year of completion the owner builder will have the burden of proving that he did not build or I rove for the purpose of sale) I as owner of the property, am exclusrvely contracting with licensed contractors to construct the proJect (Sec 7044 Business and Professions Code The Cont ctor s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant lo the Contr~s License Law) I I am exempt under Section Business and Professions Code for this reason ~ I 1 I personally plan to p~ov1de the maJor labor and materials for construcijon of the proposed property 1mpro~ement D Yes ~ No 2 ave I have not) signed an application for a building permit for the proposed work ~, 3 I ha ontracted with the following person (firm} to provide the proposed construction (include name address I phone I contractors license 4. I pic?n to ide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I a ess I phone I contractors' license number) 5. I will provide s of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type ,? / r""" ,f!5 PROPERTY OWNER SIGNATURE OAGENT DATE /"'J? ¥ - :OMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY , -, Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes Cl No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes D No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above lnfonnation isoonectand that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representaWe of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILrrlES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of strucbJres over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of sudl permit or if the bui in or work auth ch pennit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ,,/1$ APPLICANT'S SIGNATURE DATE , P9'MIT INSPECTION HISTORY RE~RT (CBR2018-0638) ' . ' \ ,, ~ Permit Typo: Work Class: Status: Scheduled Date BLDG-Residential Alteration Closed -Finaled Actual Start Date Inspection Type Application Date: 03/14/2018 Issue Date: 05/08/2018 Expiration Date: 02/12/2019 IVR Number: 10123 Inspection No. Inspection Status Owner: TRUST PULLIN PAUL AND MONICA LIVING TRUST 07-10-14 Subdivision: CARLSBAD TCT#88-03-02 UNIT#02 Addross: 2288 Camino Robledo Carlsbad, CA 92009-9354 Primary Inspector Re inspection Complete ··--·-------------------- 07/2612018 0712612018 08/09/2018 08/09/2018 08/13/2018 08/13/2018 08/16/2018 08/16/2018 09/11/2018 09/11/2018 BLDG-11 Foundation/Ftg/Pier s (Rebar) 065112-2018 Checklist Item BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) 066486-2018 Checklist lte1n BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-84 Rough Combo(14,24,34,44) 066728-2018 Checklist ltern BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-17 Interior Lath/Drywall 067180-2018 BLDG-Ftnal Inspection Checklist Item BLDG-Building Deficiency 069611-2018 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Chris Renfro COMMENTS Inspected slab on grade for garage conversion. OK to pour Partral Pass Chris Renfro COMMENTS Need to spray foam through penetrations, Around windows and bottom plate. OK to insulate the one wall with no windows and ceiling. Make exterior water tight. Move smoke detector, needs to be 3 feet from registers or tip a fan blade. Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS ·----------·-----------·--·---September 11, 2018 Complete Passed Yes Reinspection Incomplete Passed No No No No No Complete Passed Yes Yes Yes Yes Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Page 1 of 2 DATE: 05/07/18 JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2018-0638 ~ EsG1I A SAFEbwlt Company SET: III PROJECT ADDRESS: 2288 Camino Robledo ~PP LI CANT .f'" .URIS. PROJECT NAME: Convert Garage to Living Space for Pullin Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. IZJ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Shane Jost EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Shane Jost///:'.:~ .:tnl.61r,J'elephone #: 760-305-3675/) 760i3S Z(;6? Date contacted:Sh l1g (b~ Email: shanejost@gmail.com /]~fi\1$11,11 €.p@ C.Mfflt...Cbi..._ Mail Telephone Fax ~ REMARKS: Please have applicant sign sheets. Applicant picked up plans in person. By: Javier Snider (RM) Enclosures: EsGil 05/07/18 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ~ EsG1I A SAFfbuilt Company DATE: 04/13/18 0 APPLICANT 9(.,JURIS. JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2018-0638 SET: II PROJECT ADDRESS: 2288 Camino Robledo PROJECT NAME: Convert Garage to Living Space for Pullin Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: D Shane Jost EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Shane Jost Telephone#: 760-305-3675 Date contacted:~/i" (by:0 Email: shanesjost@gmail.com e..Mail .,;:;:elephomllf l"l Fax In Person REMARKS: By: Javier Snider (RM) EsGil 04/05/18 Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ___ ..,. , , City of Carlsbad cbR2018-0638 04/13/18 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. II:!! notes in bold font are current. PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). 3. Show locations of permanently wired smoke alarms with battery backup, per Section R314: Show all existing and new. a. Inside each bedroom. b. Outside each separate sleeping area in the immediate vicinity of the bedrooms. NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 4. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.8.1. Note all smoke alarms will be interconnected. ~ · • City of Carlsbad cbR2018-0638 04/13/18 5. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: Show new and existing. a. Outside each separate sleeping area in the immediate vicinity of the bedrooms. NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. Note all CO alarms will be interconnected. 6. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. 7. Provide headers for the new windows to be installed in the "room conversion sheet". 8. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 Please clearly show complete note. a. Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. Please clearly note ALL outlets will be arc-fault protected. , ~ City of Carlsbad cbR2018-0638 04/13/18 MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please provide correction response to avoid any additional undo corrections and delays. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes CJ No CJ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Javier Snider (RM) at EsGil Corporation. Thank you. DATE: Mar 27, 2018 JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2018-0638 ../. EsG1I A SAFEbui\t Coinpany SETI PROJECT ADDRESS: 2288 Camino Robledo D APPLICANT ~ JURIS. PROJECT NAME: Convert Garage to Living Space for Pullin Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Shane Jost D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Shane Jost Telephone#: 760-305-3675 Date contacte z.'1 f 18' (by:--M Email: shanesjost@gmail.com ~ail Telephone REMARKS: By: Rich Moreno EsGil Fax In Person Enclosures: Mar 19, 2018 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad cbR2018-0638 Mar 27, 2018 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: cbR2018-0638 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2288 Camino Robledo FLOOR AREA: Remodel: 228 sq-ft REMARKS: DATE PLANS RECEIVED BY JURISDICTION: Mar 14, 2018 DATE INITIAL PLAN REVIEW COMPLETED: Mar 27, 2018 FOREWORD (PLEASE READ): STORIES: no change HEIGHT: no change DATE PLANS RECEIVED BY ESGIL CORPORATION: Mar 19, 2018 PLAN REVIEWER: Rich Moreno This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad cbR2018-0638 Mar 27, 2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK#.: cbR2018-0638 PREPARED BY: Rich Moreno DATE: Mar 27, 2018 BUILDING ADDRESS: 2288 Camino Robledo BUILDING OCCUPANCY: BUILDING AREA PORTION ( Sq. Ft.) Remodel 228 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb 1997 UBC Building Permit Fee 1997 USC Plan Check Fee ... , _:__J Valuation Multiplier citv est By Ordinance Type of Review: 0 Complete Review D Repetitive Fee -··-;; Repeats ___ I Comments: D Other D Hourly EsGII Fee Reg. VALUE ($) Mod. D Structural Only 1-------11 Hr. @ * 10,604 10,604 $123.461 sso.2sj $70.37j Sheet 1 of 1 City of Carlsbad cbR2018-0638 Mar 27, 2018 • PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). 3. Show locations of permanently wired smoke alarms with battery backup, per Section R314: a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. • NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 4. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.8.1. City of Carlsbad cbR2018-0638 Mar 27, 2018 5. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. • NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 6. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. 7. Sleeping rooms shall have a window or exterior door for emergency escape. Section R310. a) Windows must have an openable area of at least 5. 7 square feet, with the minimum openable width 20" and the minimum openable height 24". b) The bottom of the clear opening shall not exceed 44" above the floor. Do not measure to the window sill. This generally applies to windows that have a height of 3' or less. See the figure below to see the correct method of measurement. City of Carlsbad cbR2018-0638 Mar 27, 2018 8. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. Residential Energy Lighting Requirements: ES 150.0(k) 9. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) 1 O. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) 11. SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. • MISCELLANEOUS 12. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 13. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes CJ No CJ 14. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Rich Moreno at EsGil Corporation. Thank you.