Loading...
HomeMy WebLinkAbout2290 COSMOS CT; ; CB040698; Permit05-13-2004 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB040698 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2290 COSMOS CT CBAD Tl Sub Type 2130504400 Lot# $1,119,84000 Construction Type Reference # SIERRA WIRELESS 37.328SF Tl OFFICE TO OFFICE COMM 0 NEW Applicant MONTELLO GEORGE 471560THST SAN DIEGO CA 92115 619229-0642 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* ISSUED 03/01/2004 SB 05/18/2004 05/18/2004 Owner GRANDONA INVESTMENT ASSOCIATES L P 2610HARRISBURGAVE FREMONT CA 92536 2*40 05/18/04 0002 GJ 02 CGF" Building Permit Add') Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $3,326 01 Meter Size $0 00 Add'l Reel Water Con Fee $2,16191 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $23517 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $21000 $4200 $000 $000 $000 $000 $5,975 09 Total Fees $5,975 09 Total Payments To Date $2,161 91 Balance Due $3,81318 BU/LDING PLANS .IN STORAGE .ATTACHED Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactionsof which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMITAPPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 Plan Ck Deposit Validated uy „. -1C. 1 PROJECT INFORMATIi:: -Oa "~Address (include FOR OFFICE USE ONLY PLAN CHECK NO EST VAL 1 ; 2161-91 Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #T i Proposed Use Description of Work i:2 CONTACT PERI" " mo' SQ FT #of Stories # of Bedrooms # of Bathrooms ..different from applicant)PA <g«5 Name 3 ,4 APPLICANT, D Contractor City Owner l~l Agent ;for^>wner State/Zip Telephone # Fax tt Name 4 PROPERTY OWNER: Address City State/Zip Telephone # Name Address City State/Zip Telephone # 5 CONTRACTOR - COMPANY NAME '*i ;1| , , , (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) fd//i c efl Name State License # Address License Class & C.~*d-f State/Zip Telephone # City Business License # IS-Q 7 <fJS~ Designer Name Address City State/Zip Telephone State License # _ 6 : WORKERS' COMPENSATION Sfi - , ' /'.' ~M-' '-„.. Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations [~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued El I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company <J- S* ,/^LyCW, e&vQtt<UvMJt. _ Policy No/ 7 ^OO^-f _ Expiration Date oC/ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) |~| CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California VARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred housand dollars,($100,000) in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code interest and attorney s fees' SIGNATURE lars,($10 /Ct&i DATE .. OWNER-BUILDER DECLARATION ' - ; "f" 4ji ..^ ' ' -i ,:, ; i, „ ,,:, I hereby affirm that I am exempt from the Contractor s License Law for the following reason I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) [~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) |~| I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement d YES ONO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) ^^___________ 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE ^COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Hi i !C .:":"•;'• Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? D YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' l~l YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' Q YES [U NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT IS; JCOJJSTRUCTION LENDING AGENCY ; :,,:. .„ . n.f £. ™: ' ff" ^ ^' I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME LENDER'S ADDRESS 9 APPLICANT CERTIFICATION !;;: ' "T!^1"" ' V '.ft: ""::"-a L, •*"" ' .,.,„, ..." ±.';7::-' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept. Building Engineering Planning CMWD St Lite fire. Plan Check # Permit* CB040698 Project Name SIERRA WIRELESS 37.328SF Tl OFFICE TO OFFICE Address 2290 COSMOS CT Contact Person BILL Phone 8589670928 Sewer Dist CA Water Dist CA Lot Date 06/25/2004 Permit Type Tl Sub Type COMM 0 Inspected., ^ / Bv fj- &&/M Inspected Bv Inspected Bv Comments <, ££»,. ^ Date Inspected Date Inspected WtfY « ^ I—' ' Approved Approved Approved Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 11/05/2004 Permit* CB040698 Title SIERRA WIRELESS 37.328SF Tl Description OFFICE TO OFFICE Inspector Assignment TP 2290 COSMOS CT Lot Type Tl Sub Type COMM Job Address Suite Location OWNER GRANDONA INVESTMENT ASSOCIATES L P Owner GRANDONA INVESTMENT ASSOCIATES L P Remarks Phone 8589670928 Inspector Total Time Requested By NA Entered By CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Associated PCRs/CVs Inspection History Date Description Act Insp 10/14/2004 17 Interior Lath/Drywall AP TP 10/12/2004 14 Frame/Steel/Bolting/Welding NS TP 10/12/2004 34 Rough Electric NS TP 10/07/2004 14 Frame/Steel/Bolting/Welding WC TP 10/07/2004 24 Rough/Topout AP TP 10/07/2004 34 Rough Electric AP TP 10/06/2004 14 Frame/Steel/Bolting/Welding NS TP 10/06/2004 34 Rough Electric NS TP 09/29/2004 14 Frame/Steel/Bolting/Welding AP TP 09/29/2004 24 Rough/Topout WC TP 09/29/2004 34 Rough Electric AP TP 09/29/2004 44 Rough/Ducts/Dampers AP TP 09/20/2004 17 Interior Lath/Drywall AP TP 09/16/2004 14 Frame/Steel/Bolting/Welding AP TP 09/16/2004 34 Rough Electric AP TP 08/27/2004 89 Final Combo PA TP Comments 2ND FLR REST RM INSP 10/8 re-loc 2nd fir waste/vents 2nd fir r r and plugs/switch T-CEIL 2ND FLR CEIL LITES 2ND FLR DUCT RE-LOC 2ND FLR 2ND FLR WALLS OK TO OCCUPY PHS II Inspection List Permit* CB040698 Type Tl Date Inspection Item 11/05/2004 89 11/04/2004 89 10/14/2004 17 10/12/2004 14 10/12/2004 34 10/07/2004 14 10/07/2004 24 10/07/2004 34 10/06/2004 14 10/06/2004 34 09/29/2004 14 09/29/2004 24 09/29/2004 34 09/29/2004 44 09/20/2004 17 09/16/2004 14 09/16/2004 34 08/27/2004 89 08/09/2004 14 08/09/2004 24 08/09/2004 34 08/09/2004 44 07/20/2004 17 07/16/2004 14 07/16/2004 34 07/15/2004 14 07/15/2004 34 07/14/2004 14 07/14/2004 34 06/28/2004 89 06/25/2004 89 06/24/2004 34 06/23/2004 33 06/23/2004 34 06/16/2004 14 06/16/2004 24 06/16/2004 34 06/16/2004 44 06/15/2004 84 06/14/2004 14 06/14/2004 24 06/14/2004 34 06/14/2004 44 06/11/2004 84 Final Combo Final Combo Interior Lath/Drywall Frame/Steel/Bolting/Weldm Rough Electric Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Frame/Steel/Bolting/Weldm Rough Electric Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Weldm Rough Electric Final Combo Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Weldm Rough Electric Frame/Steel/Bolting/Weldm Rough Electric Frame/Steel/Bolting/Weldm Rough Electric Final Combo Final Combo Rough Electric Service Change/Upgrade Rough Electric Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo COMM Inspector Act TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP PS PS PS PS PD PD TP TP TP TP TP TP TP TP TP TP TP TP TP TP PS AP CA AP NS NS we AP AP NS NS AP we AP AP AP AP AP PA AP we AP PA AP AP AP PA PA CA CA PA CA AP we PA AP we AP AP CO CO we we we CA SIERRA WIRELESS 37.328SF Tl OFFICE TO OFFICE Comments PER BILL 2ND FLR REST RM INSP 10/8 re-loc 2nd fir waste/vents 2nd fir r r and plugs/switch T-CEIL 2ND FLR CEIL LITES 2ND FLR DUCT RE-LOC 2ND FLR 2ND FLR WALLS OK TO OCCUPY PHS II T-CEIL PHS 2 CEIL LITES PHS 2 SEE CARD PHS 2 lobby & comp Rm WALL IN BATH RM NOTED IN APP PLANS OK TO OCCUPY PHS 1 SUB PNLS, TRANS PHS 1 SUB PNLS PHS 1 T-CEIL PHS 1 CEIL LITES PHS 1 DUCTS, NEW & RE-LOC PHS 1 SUPPORT WIRES® CEIL GRIDSUPPNPP BY CONTRACTOR Monday, April 11, 2005 Page 1 of 2 06/10/200484 Rough Combo TP CO SEE CARD 05/25/200417 Interior Lath/Drywall TP AP PHS 1 05/20/2004 14 Frame/Steel/Bolting/Weldm TP AP WALLS PHS 1 05/20/2004 34 Rough Electric TP AP WALLS PHS 1 Monday, April 11, 2005 Page 2 of 2 EsGil Corporation In (Partners/tip with government for (Bmhfing Safety DATE 5/4/O4 Q APPLICANT JURISDICTION City of Carlsbad a PtAiTREViEWER a FILE PLAN CHECK NO 04-0698 SET IV PROJECT ADDRESS 2290 Cosmos Court PROJECT NAME Sierra Wireless Office XJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to [Xj Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person XI REMARKS Only one complete set of the plan was provided to Esgil Corp By David Yao Enclosures Esgil Corporation D GA D MB D EJ D PC log tmsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1 V EsGii Corporation In (Partnership with government for (Building Safety DATE 4/19/04 Q APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-O698 SET III PROJECT ADDRESS 2290 Cosmos Court PROJECT NAME Sierra Wireless Office The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted fora complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Terry Montello 4715 60th Street San Diego, CA 92115 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Terry Montello Telephone # (619)994-5557 Date contacted 4!'^/c*f (by £A>T) Fax # (oiS) 2z9 Mail i—Telephone Fax*^ In Person REMARKS By David Yao Enclosures Esgil Corporation 13 GA E| MB D EJ D PC 4/12 tmsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 04-0698 4/19/O4 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO 04-0698 PROJECT ADDRESS 2290 Cosmos Court SET III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 4/12 4/19/04 REVIEWED BY David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? a Yes a No City of Carlsbad 04-O698 4/19/04 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete * AH sheets of the final approved plan shall be signed bv the person responsible for their preparation 14 Rooms with more than 10 occupants may have one exit through one adjoining room Revise exits to comply Section 1004 2 2 (The second exit from room 19 at upper floor through hallway(ad|Oinmq room) then through room 11 The second ext through more than one adjoining room ) The narrow passage way between the room 10 and 12 will be considered as different room (hallway) than the room 19 or 11 The area shall be open up so the area can be treated as part of room 11/19 Or check with city 17 Please clearly note on the plan that //////// represent existing 1hr corridor *lt appears to the window W's are new windows into existing 1 hr rated corridor The window W shall be W hr Please note on the plan *Detail A/A4 2 appears to show the existing 20 minutes door into existing rated corridor with new openings (?) You can not cut any openings into the existing 20 minutes door unless the door is tested with the openings Please clarify DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 ENTRANCES AND CIRCULATION Floors of a given story shall be a common level throughout, or shall be connected by pedestrian ramps, elevators or lifts Section 1120B 1 (steps for the server City of Carlsbad O4-0698 4/19/O4 room Is there any revision in the room'? If no, the steps become existing non- compliance If any revision in the server room, the steps shall be eliminated ) PLUMBING, MECHANICAL, AND ENERGY CORRECTIONS PLAN REVIEWER: Glen Adamek 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued Business and Professions Code All sheets of the drawings are still not signed? The final set of drawings to be reviewed just before the permits are issued. 2 On sheet A0.2 in section "D-Minimum Building and Fire Dept. Requirements", note #11 please correct to state the 1999 NEC (Not the 1996 NEC). No response and not corrected. MECHANICAL (2000 UNIFORM MECHANICAL CODE) 19 On sheet M-4 correct the note on top of the sheet to read: "3/4 inch C.D. To Drain Into Roof Drain which discharge to storm drain. (Typ.)" (Not "To Tie To Roof Drain"). Note: If you have any questions regarding this Plumbing, Mechanical, and Energy plan review list please contact Glen Adamek at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti ENERGY CONSERVATION 1 The completed and signed MECH-1 forms must be imprinted on the plans Also, imprint the MECH-1 2 of 2. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans END OF DOCUMENT EsGil Corporation In (Partnership with government for <Buifd~ing Safety DATE 3/30/04 a APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO 04-O698 SET II PROJECT ADDRESS 2290 Cosmos Court PROJECT NAME Sierra Wireless Office The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck Xj The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck 1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Terry Montello 4715 60th Street San Diego, CA 92115 Esgil Corporation staff did not advise the applicant that the plan check has been completed IXI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Terry Montello Telephone # (619)994-5557 Date contacted 3\*\l«*» (by so ) Fax # (o>n) 22?-o(W2, Mail v' Telephone Fax / In Person D REMARKS. By David Yao Enclosures Esgil Corporation E3 GA IS MB D EJ D PC 3/22 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O4-0698 3/3O/O4 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO O4-0698 PROJECT ADDRESS 2290 Cosmos Court SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 3/22 3/30/04 REVIEWED BY David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? Q Yes a No City of Carlsbad O4-O698 3/3O/O4 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 14 Rooms with more than 10 occupants may have one exit through one adjoining room Revise exits to comply Section 1004 2 2 (The second exit from room 19 at upper floor through hallwavfadioininq room1) then through room 11 The second ext through more than one adiominq room } The narrow passage way between the room 10 and 12 will be considered as different room (hallway) than the room 19 or 11 The area shall be open up so the area can be treated as part of room 11/19 Or check with city 17 Please clearly note on the plan that //////// represent existing 1hr corridor DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 ENTRANCES AND CIRCULATION Floors of a given story shall be a common level throughout, or shall be connected by pedestrian ramps, elevators or lifts Section 1120B 1 (steps for the server room Is there any revision in the room? If no, the steps become existing non- compliance If any revision in the server room, the steps shall be eliminated ) City of Carlsbad O4-O698 3/30/04 PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued Business and Professions Code The final set of drawings to be reviewed just before the permits are issued. 2 On sheet A0.2 in section "D-Minimum Building and Fire Dept. Requirements", note #11 please correct to show the 1999 NEC (Not the 1996 NEC). 4 Show the required ceiling rated fire dampers at duct openings in the fire rated ceiling membranes UBC, Section 713 11 #4 Correct the duct opening in to the fire rated corridor on sheet M-4 near building lines E and 2. Also, the duct opening in to the fire rated corridor on sheet M-5 near building lines E and 2. PLUMBING (2000 UNIFORM PLUMBING CODE) Still no plumbing drawings and calculations provided and no Plumbing responses. 5 Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths UPC Section 6100 and Appendix'A' 6 Provide gas line plans and calculations, showing pipe lengths and gas demands UPC Section 12170 7 Provide complete dram, waste and vent plans 8 New or relocated water closets and associated flushometer valves, if any, shall use no more than 1 6 gallons per flush, UPC, Sections 402 0 & 402 3, and shall meet performance standards, established by the American National Standards Institute Standard A112 19 2, H & S Code, Section 17921 3(b) 9 New or relocated urinals and associated flushometer valves, if any, shall use no more than one gallon per flush, UPC, Section 402 0 & 402 4, and shall meet performance standards established by the American National Standards Institute Standard A112 19 2 H & S Code, Section 17921 3(b) 10 Water closet bowls for public use shall be of the elongated type as per UPC Section 409 1 11 All water closet seats, except those within dwelling units, shall be of the open front type as per UPC, Section 409 2 2 City of Carlsbad 04-O698 3/30/O4 12 Show the required floor drains in the toilet rooms containing 2 or more water closets or a combination of 1 water closet and 1 urinal, except in a dwelling unit The floor shall slope toward the floor drains UPC Section 412 2 1 13 Detail how floor dram trap seal is to be maintained UPC Section 1007 0 (floor dram trap primers) 14 Show water heater size, type and location on plans as per UPC Chapter 5 MECHANICAL (2000 UNIFORM MECHANICAL CODE) 15 Show the required smoke and fire dampers at duct openings into the required fire rated corridors as per UBC, Sections 713 10 and 71311 Correct the duct opening in to the fire rated corridor on sheet M-4 near building lines E and 2. Also, the duct opening in to the fire rated corridor on sheet M-5 near building lines E and 2. 16 The fire rated corridors are not to be used to convey air to or from rooms UMC Section 602 1. A) The transfer ducts between the fire rated corridor and the restroom shown on sheet M-4 are not allowed B) No relief or exhaust is provided for the two supply air ducts into the fire rated corridors shown on sheet M-4 near building lines E and 2, and on sheet M-5 near building lines E and 2. C) No make-up air is shown for the Existing Phone Room #9 for the existing exhaust shown on sheet M-2. Please correct. 17 Show the location of the required roof access ladder to the roof mounted HVAC equipment UMC Section 910 Note # 11 on sheet A1.1 is not used on the floor plan7 Where are the roof access ladders located? 19 Detail disposal sites of mam condensate drainage from air conditioning units UMC Section 310 1 & UPC 807 2 Correct the note on to show typical all HVAC condensate to drain into Roof Drains. (Not "Tie To Roof Drain"). Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans City of Carlsbad O4-0698 3/30/O4 ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti ENERGY CONSERVATION 1 The completed and signed MECH-1 forms must be imprinted on the plans Also, imprint the MECH-1 2 of 2. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans END OF DOCUMENT - - _ . EsGil Corporation In Partnership with government for <Bui(dmg Safety DATE 3/10/O4 a AB^blGANT a CJLJI RIS) JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-0698 SET I PROJECT ADDRESS 229O Cosmos Court PROJECT NAME Sierra Wireless Office The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X] The applicant's copy of the check list has been sent to Terry Montello 4715 60in Street San Diego, CA 92115 Esgil Corporation staff did not advise the applicant that the plan check has been completed X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Terry Montello Telephone # (619)994-5557 Date contacted 3>| 1 1 /D4 (by ic. ) Fax # Mail s^Telephone ^ Fax^- In Person REMARKS By David Yao Enclosures Esgil Corporation IEI GA [X] MB D EJ D PC 3/2 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 City of Carlsbad 04-0698 3/1O/O4 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O4-O698 OCCUPANCY B TYPE OF CONSTRUCTION V-N ALLOWABLE FLOOR AREA SPRINKLERS'? Y REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED 3/10/04 JURISDICTION City of Carlsbad USE office/lab ACTUAL AREA 37328 sf STORIES 2 HEIGHT OCCUPANT LOAD DATE PLANS RECEIVED BY ESGIL CORPORATION 3/2 PLAN REVIEWER David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O4-0698 3/10/04 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC 2 Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled Section 106 3 3 3 On the first sheet of the plans indicate • Sprinklers Yes or No • Present and proposed occupancy classifications of the remodel area, • The occupant load of the remodel area(s) 4 Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E 5 A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible The building official may require a technical report to identify and develop methods of protection from hazardous materials Section 307 1 6 6 Note on the plans "All interior finishes must comply with Chapter 8 of the UBC" 7 Note on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-O and 16-B City of Carlsbad O4-0698 3/1O/O4 8 The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled See the attached correction sheet Title 24 9 The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors Title 24 (Some of the doors appears to not have 18" strike edge including door to bathrooms) 10 Specify lever-type hardware for passage doors on floors accessible to the disabled Title 24 11 Exit signs are required whenever two exits are required Show all required exit sign locations Section 1003 282 12 If exit signs are required, provide the following notes on the plans, per Section 1003282 a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign b) Exit signs shall be readily visible from any direction of approach 13 Show that exits are lighted with at least one foot candle at floor level Section 1003292 14 Rooms with more than 10 occupants may have one exit through one adjoining room Revise exits to comply Section 1004 2 2 (The second exit from room 19 at upper floor through hallwav(adioinmq room) then through room 11 The second ext through more than one adiominq room } 15 Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees Maximum leaf width is 4 feet Sections 1003 313 and 10033.14 16 Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access) Section 1003 316 17 Corridors shall have walls and ceilings of one-hour construction Show compliance 18 Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 713 2 Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 1004 34321 City of Carlsbad O4-O698 3/10/O4 19 Show rated corridors, lobbies, reception or fovers cross-hatched on the floor plans 20 Provide a complete architectural section of the corridor, showing all fire-resistive materials and details of construction for all floor, walls, roof and all penetrations Section 100434 21 Duct penetrations of fire-rated corridor construction shall have smoke and fire dampers per Sections 71310 and 71311 22 If a room with an exhaust fan has a door opening into a rated corridor, show how makeup air will be provided to the room The door cannot be undercut, nor can a louver in the door be provided Section 1004 34321 23 Provide a note on the plans stating "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and 710" • MISCELLANEOUS 24 Please refer to the following corrections for mechanical, plumbing, electrical and energy items 25 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 26 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation Thank you City of Carlsbad O4-0698 3/1O/04 PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued Business and Professions Code 2 Correct the statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC 3 Provide data on proposed hazardous material to be stored and used UBC, Section 307 and UFC a) Clearly show types of hazardous material is being stored or used Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E Provide the material safety data sheets (MSDS) b) Clearly show the amounts of each type of hazardous material to be stored and in use c) Clearly show where in the buildings each type of hazardous material is being stored or used 4 Show the required ceiling rated fire dampers at duct openings in the fire rated ceiling membranes UBC, Section 713 11 #4 PLUMBING (2000 UNIFORM PLUMBING CODE) No plumbing drawings and calculations provided. 5 Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths UPC Section 610 0 and Appendix 'A' 6 Provide gas line plans and calculations, showing pipe lengths and gas demands UPC Section 12170 7 Provide complete dram, waste and vent plans 8 New or relocated water closets and associated flushometer valves, if any, shall use no more than 1 6 gallons per flush, UPC, Sections 402 0 & 402 3, and shall meet performance standards, established by the American National Standards Institute Standard A112 19 2, H & S Code, Section 17921 3(b) 9 New or relocated urinals and associated flushometer valves, if any, shall use no more than one gallon per flush, UPC, Section 402 0 & 402 4, and shall meet City of Carlsbad 04-0698 3/10/04 performance standards established by the American National Standards Institute Standard A112 19 2 H & S Code, Section 17921 3(b) 10 Water closet bowls for public use shall be of the elongated type as per UPC Section 409 1 11 All water closet seats, except those within dwelling units, shall be of the open front type as per UPC, Section 409 2 2 12 Show the required floor drains in the toilet rooms containing 2 or more water closets or a combination of 1 water closet and 1 urinal, except in a dwelling unit The floor shall slope toward the floor drains UPC Section 41221 13 Detail how floor dram trap seal is to be maintained UPC Section 1007 0 (floor dram trap primers) 14 Show water heater size, type and location on plans as per UPC Chapter 5 MECHANICAL (2000 UNIFORM MECHANICAL CODE) 15 Show the required smoke and fire dampers at duct openings into the required fire rated corridors as per UBC, Sections 713 10 and 713 11 16 The fire rated corridors are not to be used to convey air to or from rooms UMC Section 602 1 17 Show the location of the required roof access ladder to the roof mounted HVAC equipment UMC Section 910 18 In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or III-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour Such mechanical exhaust shall be taken from a point at or near the floor UBC Section 1202 2 2 19 Detail disposal sites of mam condensate drainage from air conditioning units UMC Section 310 1 & UPC 807 2 20 Provide smoke detection in the supply air duct of an "air-moving system" for required shut-off of equipment for smoke control UMC Section 609 2 An "air- moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space UMC Section 203 0 Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans City of Carlsbad O4-0698 3/10/04 ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti 21 The licensed designer must sign the approved set of the plans ELECTRICAL (1999 NATIONAL ELECTRICAL CODE) 1 Show the ampere interrupting capacity (AIC) ratings of the sub-service equipment NEC 110-9 2 Show or note on the plans the method used to limit fault currents to 10,000 amps on branch circuits NEC 230-208 3 Show on the plan the location of the service(s) Sheet E7 1 indicated on plans has not been included in the submitted set NEC 110-26, 230-2 4 The grounding electrode conductor seems undersized for the transformer secondary NEC 250-66 5 Please show location of the new 150 KVA transformer Also, provide secondary conductors overcurrent protection NEC 240-3 6 Please change all references the NEC code cycle date to 1999 7 Note the following requirements on the prints for panelboards supplying fire alarm equipment Lockable cover, identified (red) circuit breaker, and the installation of a "lock off' device 8 Provide multiple switch light controls so that the lighting can be reduced by one half in a uniform pattern The switches must be located within sight of the lights which they control CBC Title 24, Sec 131 a-b 9 Show exit signs on the lighting plan(s) at all required exits and specify them as being self-luminous or having a second source of power (battery or generator) This is required when two exits are required per the UBC UBC 1013 4 and NEC 700-16 10 In all occupancies where the exit system serves 100 or more occupants, provide a minimum of 1 foot-candle of emergency illumination at the floor level and specify a second source of power for the emergency illumination (battery or generator) UBC 1012 2 & NEC 700-16 City of Carlsbad 04-0698 3/10/04 ENERGY CONSERVATION 1 Detail required exterior lighting controls "Exterior lighting controlled from a lighting panel within the building shall be controlled by a directional photocell or astronomical time switch that automatically turns off exterior lighting when daylight is available" 2 The completed and signed ENV-1 and MECH-1 forms must be imprinted on the plans 3 The Documentation Author and the Principal Envelope Designer must sign the ENV-1 form 4 The Documentation Author and the Principal Lighting Designer must sign the LTG-1 form Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 • REMODELS. ADDITIONS AND REPAIRS 1 When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) The area of specific alteration, repair or addition must comply as "new" construction b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features d) Existing drinking fountains (if any) must be shown to comply with all accessibility features e) Existing public telephones (if any) must be shown to comply with all accessibility features City of Carlsbad 04-0698 3/1O/O4 ENTRANCES AND CIRCULATION Floors of a given story shall be a common level throughout, or shall be connected by pedestrian ramps, elevators or lifts Section 1120B 1 (steps for the server room Is there any revision in the room?) DOORS 3 Revise plans, or door schedules, to show that every required passage door has >32" clear width, per Section 1133B 2 4 Show, or note, that there is a level floor or landing on each side of all doors The floor or landing is to be ^2" lower than the doorway threshold, per Section 1133241 5 Show or note that all hand-activated door opening hardware meets the following requirements, per Section 1133B 252 a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware b) Is to be centered >30" but ^4" above floor 6 Show or note that the maximum effort to operate doors shall not exceed 8-1/4 pounds for exterior doors and 5 pounds for interior doors, with such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding or folding doors When fire doors are utilized, the maximum effort to operate the door may be increased to not exceed 15 pounds Section 1133B 2 5 7 Show or note that the lower 10" of all doors comply with Section 1133B 2 6, as follows a) To be smooth and uninterrupted, to allow the door to be opened by a wheelchair footrest, without creating a trap or hazardous condition b) Narrow frame doors may use a 10" high smooth panel on the push side of the door 8 Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings, per Section 1133B 243 a) >24" at exterior conditions b) >18" at interior conditions City of Carlsbad 04-0698 3/10/04 c) >12" on the push side, if the door has both a latch and a closer Figure 11B-26A DRINKING FOUNTAINS 9 Plans shall indicate that drinking fountains comply with Section 1117B 1 as either a) Located completely in an alcove, >32" in width and >18" in depth b) Positioned to not encroach into accessible pedestrian ways 10 Note on the plans that the drinking fountam(s) will comply with all applicable Title 24 provisions (bubbler height, etc ) • GENERAL ACCESSIBILITY REQUIREMENTS • SIGNAGE 11 Per Section 1003 2861, tactile exit signs shall be required at the following locations a) Wherever basic UBC provisions require exit signs from a room or area to a corridor or hallway The tactile exit sign shall have the words, "EXIT ROUTE" b) Each grade-level exit door The tactile exit sign shall have the word, "EXIT " c) Each exit door that leads directly to a grade-level exterior exit by means of a stairway or ramp The tactile exit sign shall have the following words as appropriate i) "EXIT STAIR DOWN " n) "EXIT STAIR UP " 12 Tactile stair level identification signs (complying with Section 1117B 5 1) shall be located at each floor level landing in all enclosed stairways in buildings two or more stories in height to identify the floor level At the exit discharge level, the sign shall include a raised five-pointed star located to the left of the identifying floor level Section 10033 3 13 1 • COUNTERS AND TABLES 13 Where fixed or built-in tables, counters or seats are provided for the public, and in general employee areas, 5% (but never less than one) must be accessible Section 1122B1 14 The tops of tables and counters shall be 28" to 34" from the floor Where a single counter contains more than one transaction station, such as a bank counter with multiple teller window or a retail sales counter with multiple cash register stations, City of Carlsbad O4-0698 3/10/04 at least 5% (but never less than one of each type of station) shall be located at a section of counter that is at least 36" long and no more than 28" to 34" high Section 1122B 4 END OF DOCUMENT City of Carlsbad O4-0698 3/10/04 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PREPARED BY David Yao BUILDING ADDRESS 2290 Cosmos Court PLAN CHECK NO O4-0698 DATE 3/1O/04 BUILDING OCCUPANCY B TYPE OF CONSTRUCTION V-N BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA II Valuation (Sq Ft) Multiplier 37328 cb By Ordinance Reg Mod VALUE ($) per city 1,119,840 1,119,840 Bldg Permit Fee by Ordinance Type of Review I I Repetitive Fee~^ | Repeats Complete Review D Other r-i Hourly Structural Only Hour Esgil Plan Review Fee $3,32601 $2,161.91 $1,86257 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10.000.00) DATE CJT TENANT IMPROVEMENT PLAZA CAMINO REAE CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE oocs/Mlsforms/Piannlng Engineering Approvals D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check NoJSB O^f Ow^D Planner APN Address Phone (760) 602- Type of Project & Use Net Project Density Zoning A" ( General Plan P / Facilities Management Zone DU/AC CFD (in/out) #_Date of participation Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit ) Legend E>3 Item Complete [~1 Item Incomplete - Needs your actionj ' \ Environmental Review Required YES NO )f TYPE DATE OF COMPLETION Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required* APPROVAL/RESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval [~1 F~1 Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES CA Coastal Commission Authority7 YES If California Coastal Commission Authority Contact'them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 YES N0_ If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # Follow-Up Actions' 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed [~~l l"~i Inclusionary Housing Fee required. YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed7 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Site Plan. I I 1 Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes)\ CH 2 Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES NO. 2 Project complies YES N0_ tural X D D D D Zoning. 1 ^setback?* Front/ ln\e/ior Side Street Side 'Top o\slope 2 Accessory structure FrcW / InterWr Side StrsreVSide Refer \ Structure separation 3 Lot Coverage Required Required Required Required Required setbacks Required Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown 4 Height 5 Parking Required Spaces Required Shown Shown /\ (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required _ Shown _ Add.t.onal Comments of parking Space? pffi afch l/te er i. /avid pe / di<i si-te I .Co, tiff II toP 0Al/\n./l OK TO ISSUE AND ENTERED APPROVAL NMTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Carlsbad Fire Department 040698 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Building Plan Date of Report 05/18/2004 Reviewed by Fire Prevention (760) 602-4660 Name Address City, State Donald Pittman 3611 5th Avenue San Diego CA 92103 Plan Checker Job Name Job Address Job # 040698 Sierra Wireless 2290 Cosmos Ct pi Approved Bldg# CB040698 Ste or Bldg No The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements \ Approved The item you have submitted for review has been approved subject to the Subject to attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st ?nr| 3rd 040698 FD File # Other Agency ID Carlsbad Fire Department °40698 1635 Faraday Ave Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report 05/18/2004 Reviewed by Name Donald Pittman Address 3611 5th Avenue City, State San Diego CA 92103 Plan Checker °40698 Job Name Sierra Wireless Job Address 2290 Cosmos ct Ste or Bldg No THE APPROVALOF THIS SUBMITTAL IS SUBJECT TO THE SUBSEQUENT SUBMITTAL AND APPROVAL OF THE REQUEST FOR A TECHNICAL REPORT AND THE CARD READER SYSTEM Carlsbad Fire Department 040698 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report Q4/Q5/20Q4 Fire Prevention (760) 602-4660 Building Plan Reviewed by C. Name Address Terry Montello 4715 60th Street City, State San Diego CA 92115 Plan Checker Job Name Sierra Wireless Job# 040698 Job Address 2290 Cosmos ct Bldg# CB040698 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2nd 3rd 040698 FD File # Other Agfinny in Requirements Category: Building Plan Requirement Pending 0514 Provide Technical Report To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to the inspection of the department, the Chief is authorized to require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and the facilities and appurtances situated thereon, to recommend necessary changes Requirement Pending 05 32 Additional Requirements or Comments Card reader system shall be approved when submitted by separate contractor Page 1 04/05/04 Sent By "donald pitman design, mo , 6192995544: Jun.14.04 3 ^ ^ ^ TVUI design,inc. m FAX MEMO: H To: TIM PHILLIPS Fax* (760)602-8560 iH From; Donald Pitman ill Project / Reference: Sterra wireless 04-0698 S Remarks; June 14, 2004 Tim Attached you wtli find our revised ceiling detail for the above referenced project Let me know if you have any questions Thank you Don CC Manuel Pena (760) 476-8701 Mtke Slaver. (858) 552-0604 Michelle Anderson ,. (760) 431-3793 3900 Fifth Avenue Suite 290 San Diego, CA 92103 t 816 399.0011 f1 619 299.S544 Sent By donald pitman design, me 6192995544,Jun-15 04 9 39AM,Page 1/1 UJ 0 <Do to z LU i 02 TITLE 24 REPORT Title 24 Report for: SIERRA WIRELESS 2290 COSMOS CT CARLSBAD, CA 92009 Project Designer: Report Prepared By: HADI MAHZARI ENERGY CONSULTING GROUP 8015 BALBOA AVENUE SAN DIEGO, CA 92111 (858) 268-0660 Job Number: Date: 2/23/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards This program developed by EnergySoft LLC (415)883-5900 EnergyPro 3 1 By EnergySofl Job Number User Numberii2984 Sent By donald pitman design, me , Received 4./28/O4 8 39AM, 04/28/2804 89 23 8585520684 6192995544, May-18-04 12 23PM, Page 4/5 - •*" UUMd-LU p j_ midi i t_i tr o _L L.J i i , -i-t iv- , i- a ^c= t-. PACIFIC BUILDING GRP PAGE 0&/07 4C080. CERTIFICATE OF LIABILITY INSURANCE ^5ftH "™EEZ naauefH t 8 Levine Xaaurance Servxcaj , lac 3317 camel Mountain Road flan Diago CA 92121 Phon«-IS«-4Sl-lfi92 rax-8Si-481-T953 MSIMSO Aftft DiQQO CDw*.1, §203 THIS CERTIFICATE IS ISSUED A3 A MATTER OF INFORMATIONONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATEHOLDER THIS CERTIFICATE DOES NOT AMEND. EXTEND ORALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORDING COVERAGE INSURER* Stata Coop Xnjuranoa Fund NSUW»8 MUSRC IMUIERD- wcuwae NA1CC COVERAGES ANY REOU HEMEHT TERM OR CONDITION OP ANY CONTRACT OR OTHEK DOCUMENT WTTH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR FOUCIES AOOHEOATC UMIT3 MOWN MAY HAVE 9CEN SEDUCED IV PAJO CLAIMS ••ftLTH A Si«n TT»« or fMUMNce UNMAL UAMJTV COMkCRCM. GCMDAL LIMUTT 1 CLA&G u^pc 1 1 occuA OEM*. AOOOCiAre IIMT fP^gg ft* ANY AUTO *L CffftO AUTOS soexieo AUTOS «WOAUTC« NOMOVMO) AUTOS CAiu6fuAU.rTv __ ANY AUTO CLAMS MADE 1 OCCUC*«t.£ woflxon eoM^iMiArON AND POUCYNUHM* 1 7*WiiXviJ&Tr? rftfydSHfiW 1 L«m 1780021 03/01/04 06/01/04 SACK OCCUMCNCE PREMSESIExiaUfiMI «CO EXP (Any v«wrMA) FEMONH * *CV »»A*Y cc-crv^ «ccrc J-IT POCEX.CTS coa>cpACfi J^-^C^,-, BODILY njjSY (Pw icciart) PROPERTY 0<MMe AUTO OM.Y - o Acaoeir ^ EA *cc ALTO ONLY ^^j. OCH OCCLHSSMCE ACOABCATE „ [ vw. S^A.^ r |0"r-X |TC4)ri.VBTS 1 1 ER E L. EAL> ACC.C9T euDlS£ASe £AS*t3»S C L ClSCAJg T^LiCT LtMI~ 1 1 1 t 1 1 1 f 1 • 1 1 1 1 I 1 1 1 < 1000000 11000000 1 1000000 of icnmoM or O^ERATIOMI / LOCATION! ' VCHICLEI / BXCILMIOMS Aboib v snooftsfMt^r i STECIAI ntovnioNi Proof of Insurance CERTIFICATE HOLDER CANCELLATION rORXOUR " IOLU> AMT or n re AOOVC cocnmco rouoca oc uncckkED Krone n c c»r»v«nof, DAT! THEREOF TX H&,MC MUREH WH.L ENOSAVOK TO MAX. 30* OArl VMUTKn NOTlCf TO THE CUnFICATE HOLOCK NAWR) TO THE LEFT BUT FAUKV TO OO SO IKALL FOR YOUR ZNTOBMATION ONIiY" (»OS«NOC8UGATIONORLl«8«.rTYOF«MYK«OLKlMT(<E»l»UI««.IT»*CINT»ai« MTKeSENTATIVGI JtL^ 'fasT^-C. ACORD 2) (2001/01)W ACORO CORPORATION 1388 1 ,r hi tv, , T^> VWlA• £ ^^$ o> 3 >v ^^ , y d H > -ji i i; ^i '-- S CJ; CcT •a o w JH T;r-s- -n c^ :y L~-l •'"! -' f^ ^-" •j- rn o "-T -C -n n, "0-i g ,-j > g p; j? c, a m :.. r, C1' ~ ?; o ~t~t ,'•*•• .-».^iii ?' ^Zn ^,u M ; 3D 2 !D 3D H O 0^0 =S m 5) -r,-1 H n .,;i m•-. rn „ i "•""!