Loading...
HomeMy WebLinkAbout2290 COSMOS CT; ; CB940196; PermitB U I L D I .,N G P E R M I -T 'o3/16/94 ,12:07- =. -.-<- •" -•.—•- \ Page 1 of 1 , - • "'•-" -"" " . C-'~. -- Toh Address- .2290, COSMO5~eT Permit Type .INDUSTRIAL,. TENANT IMPROVEMENT ^ Parcel No:. 213-050-44-O.f Va.luation.- 37-, 5 00 , .^t rfi ^ 7"fc' ~ —Construction ^-- - Reference* ,nT REMODEL OF EXISTING OFFICE AND, • SHOWER ROOM ,. _,.._^ Permit No CB940196 Project No. A9400280 Deve3.'>pr:f-n!t No Aool/Ownr - R G .PETTY ,Appl/uwnr. ^^ FLANDE-RS DRIVE,#J SAN DIEGO^ CA. 92121 619-458-9440 Status ISSUED Applied 02/24/94 Apr/Issue- 03/16/94 Filtered By. MDP •*• * * Fees Adjustments: Total Fees. Fee description 663.00 . 00 663 00 Total Credits: Total Payments: Balance Due: Units . Fee/Unit 00 88 00 575.00 Ext fee Dat'a Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Install/Repair Water Line > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Enter "Y" for Remodel * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > Each Exhaust Fan * MECHANICAL TOTAL 3 1 7.00 7. 00 1 1 9. 00 6. 50 337 00 219.00 8 00 564 00 20.00 Y 21 . 00 7 00 48 00 10 00 Y 10 00 Y 20. 00 15 00 Y 9.00 6 50 31 00 FWAL/APPROVAL INSP. CLEARANCE ~ / CITY OF CARLSBAD 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161 DJ'LICATION City of Carlsbad Building Department 2075 Las Palmas Dr.. Carlsbad. CA 92009 (619) 438-1161 1 PERMIT TYPr. j. A - U Commercial U New Building STTenam Improvement B - O Industnal D New Building D Tenant Improvement C - D Residential D Apartment DCondo D Single Family Dwelling D Addition/Alteration D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing D Mechanical D Pool D Spa D Retaining Wall D Solar D Other 2. PROJliCT INFORMATION PLAN CHECK NO. ESTVAL PIAN CK DEPOSIT_ VALID BY DATE 5895 02/24/94 5001 01 02 C-J>T 63-00 FOR OFFICE USE ONLY Address XJ 3 9 2? Nearest Cross Street . uuiluing or suite NO DtiSCjK.ll 11UIN Subdivision Name/Number Phase No G 2 Energy Calcs D 2 Structural Calcs D 2 Soils Report D 1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE DESCRIPTION OF WORK SQ FT NJjJ.diller /t» #OF STORIES a UUN1 AL'rPJiK.SUNJjJ.dillerent from applicant)-STV/V/ 6- NAME CITY ADDRESS STATJE-" C ft- ZIP CODE DAY TELEPHONE 4 ArrLlCAN 1 LON 1 RACI UR CITY f5 O 5 HHUi'iiKTY UWNKK STATE FOR LUN 1 RAL, 1UR LJUWNhR LJAOhNl FUR UWNhR ADDRESS ZIP CODE DAY TELEPHONE NAME CITY STATE ADDRESS ZIP CODE DAY TELEPHONE 6 CONTRACHJK NAME f> CITY ADDRESS ZIP CODE LICENSE CLASS DAY TELEPHONE CITY BUSINESS LIC # 1 *f % CITY STATE C/*?" ZIP CODE STATE LIC #. Workers' Compensation Declaration I hereby allirm that I have a certlticate of consent to self-insure issued Dy the Director ot Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab C) INSURANCE COMPANY "P f POLICY NO H *•/ §3 V^'?3EXP1RAT10N DATEH *•/§ sr whicCertificate ot hxemption I certify that in the perlormance ol the work lor so as to become subject to the Workers' Compensation Laws of California ich this permit is issued, I shall not employ any person'm any manner SIGNATURE DATE 8 (JWNl'.K-BULLL>hH DFjULAHAUON Owner-Builder Declaration I hereby attirm that 1 am exempt trom the Contractors License Law tor the tollowing reason D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale ) D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 9 (JUNi>IKU(Jll(JN Ll'lNIJINti AtiKNCJY " " 1 hereby allirm that there is a construction lending agency lor the perlormance ot the work tor which this permit is issued (.Sec 30970J (Jivil Code) LENDER'S NAME LENDER'S ADDRESS 10 APPUCJANl l certify mat i nave read tne application and state that the above inlormation is correct I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSIIA. An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code) APPLICANTS SIGNATURE DATE C WHITE: File YELLO; W^iphcant PINK. Finance DEPT: BUILDING FINAL BUILDING INSPECTION ENGINEERING {FJBIU? PLANNING U/M PLAN CHECK#: CB940196 PERMIT#: CB940196 PROJECT NAME: REMODEL OF EXISTING OFFICE AND SHOWER ROOM ADDRESS: CONTACT PERS ON/ PHONE #: MH/ DAVE/4 58 -94 40 SEWER DIST: CA WATER DIST: CA RECEIVED APR 2 5 WATER DATE: 04/22/94 PERMIT TYPE: ITI INSPECTED BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: c- CITY OF CARLSBAD INSPECTION REQUEST PERMITS CB940196 FOR 04/22/94 DESCRIPTION: REMODEL OF EXISTING OFFICE AND SHOWER ROOM TYPE: ITI JOB ADDRESS: 2290 COSMOS CT APPLICANT: CONTRACTOR: OWNER: 2290 R.G. PETTY PHONE: JPHONE: ' PHONE: STE: 619 45 INSPECTOR AREA TP PLANCKtf CB940196 OCC GRP* B-2 TYPE VN LOT: REMARKS: MH/DAVE/458-9440 SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: CD LVL DESCRIPTION 19 29 39 49 ACT COMMENTS ST PL EL ME Final Final Final Final Structural /H T Plumbing / Electrical \ Mechanical / * ***** INSPECTION HISTORY ***** DATE DESCRIPTION 041194 Frame/Steel/Bolting/Welding 041194 Rough Electric 041194 Rough/Ducts/Dampers 040894 Frame/Steel/Bolting/Welding 040794 Frame/Steel/Bolting/Welding 040494 Exterior Lath/Drywall 040494 Frame/Steel/Bolting/Welding 033194 Frame/Steel/Bolting/Welding 033194 Rough/Topout 033194 Rough Electric 033194 Rough Electric 033094 Frame/Steel/Bolting/Welding 033094 Rough/Topout 033094 Rough Electric 033094 Rough/Ducts/Dampers 032994 Frame/Steel/Bolting/Welding 032994 Rough/Topout 032994 Rough Electric 032494 Frame/Steel/Bolting/Welding 032494 Rough/Topout 032494 Rough Electric 031894 Underground/Under Floor 031794 Underground/Under Floor ACT AP AP AP NS CO AP AP PA AP AP AP NR AP PA AP AP AP AP CO CO CO AP NR INSP TP TP TP PD TP TP TP TP TP TP 44 TP TP TP TP TP TP TP TP TP TP PK PK COMMENTS T-BAR EXISTING CEILING LIGHTS RELOCATED EXISTING SEE JOB CARD SHOWERS ND STRAPING VERT,SHOWER RM SHOWER RM SHOWER RM SHOWER RM SAMR CORR SHOWER STALLS CEILING WIRING DUCTS,FANS N/INCL SHOWERS WALLS,N/INCL SHOWERS SEE JOB CARD OK TO POUR CONCRETE NO PLANS/NO SUPT ON JOB 1\\TS B ADDRESS INSPECTION INSPECTOR PLANCK AURIVE:TIME LEAVE LVL DESCRIPTION ACT COIUIENTS PEl^tlTS 6/13/09 BB2SQO CHANGE OF ADDRESS NOTIFICATION NEW ADDRESS 2290 COSHOS CT NEW PHONE NO.438-8099 NAME OF BUSINESS VIA SAT TYPE OF BUSINESS RESEARCH OWNER'S NAME MARK DAMKBERG OLD ADDRESS.G120 PASEO DEL KO&T2 J2 OLD PHONE NO 438-8099 REMARKS DATE APPROVAL. WHITE Finance GREEN Planning CANARY Redevelopment PINK Building GOLDENROD Fire ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 560-14^8 f APPLICANT JURISDICTION. . CA^LSg/ti3 LjPLV< CHECKER i~?ILE COPY ?T.SN CHECK NO 1V-JK SET: JL Gb?S [JDESICA'ER PROJECT ADDRESS: ^2*/O COSMOS CT PROJECT NAME: The plars transmitted nerewitn have been corrected where necessar_. and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the ;insdiction's building codes when minor deficien- cies ider.ified OAJ Tfte, rt-TTflcffg.p SH-e£~r =re resolved and checked ry ouilding department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resuo-itted for a complete recheck. The chec< list transmitted herewith is for your information. The plars are being held at Esgil Corp. until corrected plans are submitted for recheck. Ii The applicant's copy of the check list is enclosed for the '—' jurisdiction to return to the applicant contact person. -The applicant's copy of the check list has been sent to: j|^} Esgil stsff did not advise the applicant contact person that plan chec< has been completed. [] Esgil staff did advise applicant that the plan check has Vifson f/~\rr — 1 o<- o/^ 'Dover^n /•• /~i nt- = r- *• a A »been coirrleted. Person contacted: Date contacted: Telephone § REMARKS: By: "c7~£ P/SCH*£j^ Enclosures ESGIL CORPORATION j/6 DGA L:M DPC zr /VOTE-.Tf4-£gr /IT T~H-€ o-C-A /3 /IT THf Ul 6 f+T TD T?fe CvC '..So »'THw Z- ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: I// /? V JURISDICTION: _ CARLSBAD _ <--QPLAN CHECKER QFILE COPY PLAN CHECK NO: 7 V~ tf4> _ SET: -3T _ QUPS QDESIGNER PROJECT ADDRESS; 2.2-^Q ~ PROJECT NAME: The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. -, The plans transmitted herewith will substantially comply J with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: DA (/£- ^6 SO FLANDERS QtZ~ SviTZ. X, SA*> D/£6O Esgil staff did not advise the applicant contact person that plan check has been completed. II Esgil staff did advise applicant that the plan check has — been completed. Person contacted: Date contacted: Telephone I REMARKS: By; P£.TE FlSCH^J^ Enclosures: ESGIL CORPORATION M!GA DCM (D PC PLAN CORRECTION SHEET TENANT IMPROVEMENT PLAN CHECK NO.: IJ~ /9b Date plans received by jurisdiction: JURISDICTION; CARLSBAD . Date plans received by Esgil Corporation. TO: Date initial plan check completed. 3///?y Bv PROJECT DATA Applicant contact person: OCCUPANCY: £^ Tel. BUILDING USE: FOREWORD; PLEASE READ TYPE OF CONSIRPCnON; ^3ZT/J SPK^ Plan check is limited to technical requirements ACTUAL AREA: T^T <* I5~OO contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National ALLOWABLE AREA: <v/O C^MA/6£ Electrical Code and state laws regulating energy t, H conservation, noise attenuation and access for the STORIES: handicapped The plan check is based on regulations enforced by the Building Inspection HEIGHT: * J; Department. You may have other corrections based on laws and ordinances enforced by the Planning SPRINKLERS: TS-S Department, Engineering Department, Fire Department or other departments. Code sections cited are OCCDPANT LOAD; ~T3" - /5~ based on the 1991 UBC. Tt>7>H- A*-£4- •£ 3~7O The circled items listed need clarification, modification or change. All items must be REMARKS: satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e.. plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. LIST NO. 41 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1991 UBC Please nake all corrections on the original tracings and submit two new sets of prints, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, to. The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(d). Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 302(d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. X /• On the first sheet of the plans indicate- Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor v,here the tenant improvement is located Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B A complete description of the activities rind processes that v.ill occur in this tenant space should be provided. A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible. The building official may require a technical report to identify and develop nethods of protection from hazardous materials. Section 901(f). If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. " Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor- ceiling assemblies or roof-ceiling assemblies. 8/4/92 a/. Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. Show safety glazing in the following locations, per Section 5406(d): a. Where the nearest edge of glazing is within a 24-inch arc of either side of a door in a closed postion (unless there is an intervening v.all between the door and the glazing or if the glazing is 5'-0" or higher above the valking surface). b Glazing greater than 9 square feet with the bottom edge less than 18" above the floor and the top edge greater than 36" above the floor (unless the glazing is more than 36" horizontally away from walking surfaces or if a complying protective bar is installed). c Glazing in shower and tub enclosures (including windows within 5 feet of tub or shower floor). Provide a section view of all new interior partitions. Show. (a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". (b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). (c) Wall sheathing material and details of attachment (size and spacing of fasteners). (d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 510(b). Note on the plans: "All interior finishes must comply with Chapter 42 of the UBC". Specify "Class flame spread rating (minimum) for ." 27.) Note on plan that suspended ceilings shall comply with UBC Tables 47-A and 23-P. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor a*pove so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(f). In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L F ). Section 2516(f). Storage areas exceeding 1000 sq. ft. in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an autonatic sprinkler system, then the occupancy separation need not be provided Section 702(c) An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet Section 3802(c). The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24, Part 2. The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. Specify lever-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. 705(c). Section 3/. A required between the _-hour occupancy separation is _occupancy and _occupancy. Table 5-B. Ducts penetrating occupancy or area separation walls must have fire dampers. Section 4306 (J). In areas where the occupant load exceeds , two exits are required. See . Table 33-A. Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served. Section 3303(c). .7/8/92 -The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303(a). Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 3303(e). Exit signs are required whenever two exits are required. Show all required exit sign locations Section 3314 (a). Show that exits are lighted with at least one foot candle at floor level. Section 3313(a) Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3304(c). Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(f). Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3304(b). Applies to door(s) Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access). Section 3304(i). Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). Revolving, sliding and overhead doors are not permitted a.s exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). Provide panic hardware in Group A,E,H-l,H-2,H-3 and I occupancies. Chapter 33. Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). ¥• Corridors must provide continuous protection to the exterior of the building. Interruptions by an intervening room is not permitted. Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches vide and 7 feet high to the lowest projection. Corridors serving less than 50 occupants may be a minimum of 36 inches in width. Section 3305(b). When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or nore occupants shall have v,alls and ceilings of one-hour construction Show compliance or clearly show on plans which of the following exceptions has been satisfied: a. Corridors greater than 30 feet wide vhen the occupants have an exit independent from the corridor. b. Exterior sides of exterior exit balconies. c. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. d. Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet in height need not be fire resistive, provided they are constructed in accordance with Section 1705 and are not more than three fourths of the floor- to-ceiling height. Section 3305 (g). Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3305(g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). Section 3305(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels. 5/28/92 yf.If non-rated corridors are used per Section 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: 1. Corridors are non-rated per Section 3305(g), Exception 5. 2. Smoke detectors shall be maximum 30' on center. 3 Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising vail constructed as for a one-hour corridor wall. Clearly show vhere the non-rated corridor system terminates and a rated corridor system commences. One-hour fire-rated corridors shall have interior door openings protected by tight- fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic- closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305(h). poO/2J 1,7,8,1,!OeiZ.t 1} Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed glazing listed and labeled for a fire- protection rating of at least 3/4-hour. Section 3305(h). Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor ceilings. Combination fire/smoke dampers are required at duct penetrations of rated corridor vails. Section 4306(j). A/e>u_/At-CS AT 71} 5 a. AT iz. 10. A- / If a room with an exhaust fan has a door opening into a rated corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)l. If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. Section 3305(j). If a second door is provided at the elevator entry, note that it will be readily openable from the car side vithout a key, tool or special knowledge or effort Section 5106. New provisions in Chapter 43 of the 1991 UBC require special treatment of penetrations at fire-resistive assemblies. Provide typical details on the plans shoving how the fire- resistive integrity will be maintained at the following conditions (Include the names and ICBO numbers (or equal) for any sealant): A. THROUGH-PENETRATIONS (through the entire assembly): 1. Fire-resistive bearing vails and/or walls requiring protected openings shall have penetrations protected with through- penetration fire stops having an F- rating, T-rating or complying with UBC Standard 43-1, depending on their locations, sizes and combustibility. 2. Fire resistive floor/ceiling assemblies shall have penetrations protected with through-penetration fire stops having and F-rating, T-rating or complying vitn UBC Standard 43-1, depending on their sizes, combustibility and whether the penetrations are in walls above. B. MEMBRANE-PENETRATIONS (through only one side of an assembly): 1. Fire-resistive walls (whether bearing or not and whether requiring fire protected openings or not) shall have penetrations protected with membrane-penetration fire stops having an F-rating or complying with UBC Standard 43-1, depending on their size and combustibility. Limited steel electrical outlet boxes (not exceeding 16 sq. in., nor more than 100 sq. in. for any 100 sq. ft. of wall) require no protection. 2. Fire-resistive ceilings shall have no penetrations, except for noncombustible sprinkler pipes and steel electrical outlet boxes as described above. NOTE: The plans should indicate the various fire-stop ratings required for all penetrations. Provide a note on the plans stating "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 4304 and 4305". 8/4/92 letu.All roof-mounted equipment shall be concealed from view. Provide structural detailing for the screening. HTSGELLAKKJOS x N(105/Please see additional corrections or remarks that follow. To speed up the recheck process, note on this list (or a copy) where each correction iten has been addressed, i e , plan sheet, note or detail number, calculation page, etc rlQ7.) Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe then and where they are located in the plans. Have changes been made to the plans not resulting fron this correction list' Please check. Yes NO The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone nunber of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact _ _ P&71L F/KtfcA^ _ at Esgil Corporation Thank you. Enclosures: 1. _ 2. _ _ 3 _ 6/25/93 MECHANICAL, PLUMBING, ENERGY PLAN CORRECTION SHEE1 JURISDICTION:DATE:~~ ' PLAN CHECK NOHBER:V "" ' ^ GLEN ADAHEK PLAN CHECKER: D /_ i <z &-r' «j c. ( £ r e - C? /^ To o o *^t- S o ty r fC.tr dels are valued over $79,119 and specific0e0)^t c0)x;s:quirements cannot be metLaw allows equivalent facilities to beted if strict compliance with theations would create an unreasonablehips cannot be waived unless there arecu a-n 01 ^ 01 Olcuuu(0 0)sz EH rH CUuu(C 3 73Ol InOJ (0 rH XI 01 uu CN cal or legal barriers that preventding either full access compliance oralent facilitation compliance. When boths and equivalent facilitation are waivedle enforcement official, ratification isH 01 X!a H > > HO 3 rH D1a <u Ol "-H.0) "u0 >,(0 XI T3 (0o03 01 rH(0 (1)a c(0 XI 73(U rH rl 3<u rH CO O Q, flJ U MH t-i ?-S?oicuE 8S^ 01 o in CU ?«e rlXI O w ^.H <0 Ol <0 OJ 3 C... O Ol Oow5S C^rHS, S35-S 3 = (U XI > rH 4J 01 JJ OO3rlOrH -73 rH .U rH O H rH 3 01 3 H (U u m C OH •a<0 co w en iJ % CU S^ci«5§ n-g °^ s.*2&o q c^3 £ci aco y 3 EH P U25 £ uM Wa *~fcacn cocowoCJ •ations, s:nts and orH >(0 O rH01 a O (0c c rH (U— 4J cu73 no 73 rH H&0) VH isCU UC 10 H rH I"Ou to remodeledpsCUVH(0 T3<L> rH CU T)O cu rH O.u CUoc s01 (0 0) rH Hu 01cn ^cu Ou Cnu cx: (0 H iJ 73 (0 C 01 <0 rH 73 Oi 4 .id 01 )H 01rH j<: (0 xi a (0 rH N In ECU (0 (0 3 <0 • S K CJ PS 1 (0 X) O 73 <U 'unary entiEntranceExit Docrl rH 05 X) 05C rl S 01 iH (0 01 73 CU 0) C rH O <UX!73 ftO OJ <U OJIH JJ 01 S-o> c SH <0CUcn « C2 5%f(0 10 73>iCncu (0 H (U C H CO CU H C •H JH <U lit 73a cuH rHx: H OT <4H 73 <u 73 rH 5 rH<u cu' ^•gQ i—I 3O XI 01 <u h «a a 03 V-l <U •O 0) O (U (Q r 3 > (U CJ <V TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction Plan Check No. References to section numbers v,ith prefix "2" are to Title 24, California Code of Regulations, Part 2 (California Building Code). Prefix "3" is for Part 3 (California Electrical Code). Prefix "5" is for Part 5 (California Plunbing Code). Exemptions clamed for any item shall be requested in writing and shall include all data needed to determine "unreasonable hardship" as described in Section 2-422. SITE DEVELOPMENT 1. HANDICAPPED PARKING SPACES a. Provide _handicapped spaces. 2-7102(b) b Space shall be so located that handicapped persons are not compelled to wheel or valk behind parked cars other than his/her own. 2-7102(c) c. Parking space shall be a minimum of 9 ft.xlS ft. with adjacent marked 5 ft. loading zone. Double space shall be 23 ft. wide. Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle. 2-7102(c). d. Maximum slope of parking surface in any direction shall not exceed 1/4" per foot. 2-7102(e). e. Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the parking stall). 2-7102(f) f. Entrance to parking area (or at each stall) shall have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away. 2-7102(f) g. If covered parking is provided, then a reasonable portion of the total number of stalls reserved for the disabled shall also be covered. 2-7102(a) h. Entrances to and vertical clearances within accessible levels of parking structures shall be 8 ft. 2 in. to anystructural member, duct or pipe. 2-7102(g) 2. CURB RAMPS a. Curb ramps shall be located wherever pedestrian path crosses curb. (2- 7103(a)) b. Curb ramp shall be 48" min. width (2- 7103(b)) with maximum slope of 1 in 12. 2-7103(d) c. A level 48" mm. depth landing is required at top of curb ramps over entire curb ramp width. 2-7103(d) d. If no landing is provided, the slope of flared sides shall not exceed 1 in 12. 2-7103(d) e. Surface is to be slip contrasting finish sidewalk. 2-7103(f) resistant and a from adjacent f. Border markings shall be 12" wide of l/4nxl/4" grooves, 3/4" apart, located at top and sides. 2-7103(h) 3. WALKS a. Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-7101(a) b. Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec. 2-3307. 2-3325(c) c. Walk width shall be 48" minimum, and shall have slip-resistant surfaces. 2-3325(a) d. The maximum cross slope shall not exceed 1/4" per foot. 2-3325(a)3 e. Gratings are not possible. 2-3325(b) allowed whenever f. At each gate or door a 60"x60" level area is required when the gate swings toward the walk. 2-3325(e) g. A 48"x44" deep level area is required when the gate swings away from the walk. 2-3325(e) h. A 24" clear space is required at strike side of gate or door. 2-3325(e) 4. PEDESTRIAN RAMPS a. A path of travel with a slope greater than 1 in 20 shall be considered a ramp. 2-3307(a) b. The maximum slope shall be 1 in 12. 2-3307(c.l) c. The width shall be 48" minimum. A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more. Group R Occupancies may be 36" when the occupant load is 50 or less. 2- 3307(b.l) d. The surface of ramps shall be slip- resistant. 2-3307(g) e. A 60" intermediate landing is required at maximum elevation change of 30" and 72" landing at each change of direction - - (over 30 degrees). 2-3307(d 1) f. Landings are required at top and bottoa of ramps. 2-3307(d 1) g. Bottom landing shall be raininuin of 72" in the direction of travel. Fig. 2-33- 11A h. Top landing shall be 60" x 60" nininua. 2-3307(d.l) i. When door swings onto top landing, minimum depth of landing required is door width plus 42". 2-3307(d 1.) j. Top landing shall have 60" mm. width when door swings onto the landing, with 24" on strike side of door at exterior ramp, or 18" at interior ranp. 2-3307(d 1) k. Ranp handrails are required on each side of ramp, when slope exceeds 1 in 15. 2- 3307(e.l) 1. Ramp handrails shall be continuous, located 30"-34" in height above ranp surface, with 12" extensions beyond top and bottom, and the ends returned. 2-3307(e.l) m. Handrails shall be 1-1/4" to 2" cross section, spaced minimum of 1-1/2" froo wall. 2-3307(e.l) n. A 2" high curb or wheel guide rail centered 3" + 1" above ramp surface is required on both sides where not otherwise bounded by walls when the ramp -exceeds 10 feet in length. 2-3307(h.l) 5. SPECIAL ACCESS LIFTS a. Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health. 2-5107(a) b. The lift platform shall be of sufficient size to accommodate a wheelchair (30"x48"). 2-5107(a) c. There shall be a level and clear floor area or landing (60"x60") at each level for access to the lift. 2-5107(a) 6. HAZARDS a. Provide 80" headroom from walkvay surface to any overhanging obstruction. 2-3326(b) b. Headroom of 80" minimum shall be maintained for walks, corridors, aisles, etc. 2-522(f) c. Protruding objects with leading edges between 27" and 80" above finished floor shall not protrude more than 4" into walks, corridors, etc. 2-522(f) d. Free standing objects mounted on posts between 27" and 80" above the floor nay project a maximum of 12". 2-522(f) e. Abrupt changes in level exceeding 4" adjacent to walks, except between walks and adjacent streets or drives, shall be identified by 6" high warning curbs abo\e walk surface. 2-3326(a) ENTRANCES AND CIRCOLATIOH 7. ENTRANCES, DOORS, VESTIBULES AND CORRIDORS a. All primary entrances to buildings shall be accessible to the handicapped. 2-3301(f) b. All required passage doors shall have 32" clear opening at 90 degrees (36" door). 2-3304(f) c. At least one of a pair of doors shall meet the minimum 32" clear entrance width requirement. 2-3304(f) d. Threshold shall be no higher than 1/2" above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more than 1/4". 3304(i.l) e. Exterior level landing may slope up to 1/4" per . foot in any direction for surface drainage. 2-413 f. Door hardware shall be of the lever or push type, mounted 30" to 44" above the floor and ba operable - with a maximum effort of 8.5 Ibs. for exterior doors and 5 Ibs. for interior doors. 2-3304(c), 2- 3304(1.2) g. The lower 10" of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304(i.3) h. Building entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan. The symbol shall be a white figure on blue background. 2-522(b) i. At turnstile, provide an access gate, 32" clear width opening, within, 30 feet of turnstile. 2-3304(1.4) j. There shall be a clear area, on each side of door, 60" deep in direction of door swing and 44" deep in opposite direction of door swing. 2-3304(1.1) k. Width of clear area on the swing side of the door shall extend 24" past strike jamb for exterior doors and 18" past strike janb for interior doors. 2-3304(i.l) 1. The space between two consecutive doors (vestibule) shall provide a mininua of 48" clear depth between the open door and a second closed door Doors in a series at a \estibule shall swing in the same direction, or away froa the space between them 2-3304(i 1) n. For corridors over 200 feet long, see special requirements of Sec. 2-3305(b)2 8. FLOORS a. Floors of a given story shall be a coraaon level throughout or shall be connected by pedestrian ramps, passenger elevators, or s pecial access lifts. 2-522(e) 9. STAIRWAYS NOTE: Only applies where disabled access is provided or required to other levels. a. Treads shall have smooth, rounded e>T>osed edges and be slip resistant. 2- 3306(s) b. Nosirg shall not project more than 1-1/2 inches past face of the riser below. 2-3306(s) c. Risers shall be sufficiently solid. 2-3306(s) d. The upper approach and lower tread of each flight of stairs shall be marked with a. contrasting colored strip 2" in width. 2-3306(r) e. On exterior stairs, each tread shall be marked as noted above. 2-3306(r) f. Handrails are required on each side of stairway. 2-3306 g. Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread width beyond bottom nosing and returned to wall/newel post. 2-3306(j.l). h. Handrails shall be 1-1/4" to 2" in gripping cross section and 1-1/2" clear of vail. 2-3306(j.l) i. Approved stairway identification signs shall be located at each floor level in all enclosed stairways in buildings two or more stories in height. The sign shall identify the stairway, indicate whether there is roof access, the floor level, and the upper and lower terninus of the stairway. The information shall be presented using raised Arabic minerals and raised braille synbols which confora to Section 522(b)3. The sign shall be located approximately 5 feet above the floor landing immediately adjacent to the door on the strike side. Signs shall cocply \.ith requirements of U.B.C. Standard No. 33-2. 10 ELEVATORS a. Provide clear inside elevator car dimensions as required by U B.C. Section 5103(d) 6 and Title 24 2-5103(d.l). 1. At least one elevator in buildings 4 or more stories in height: 80" by 54", with a 42-inch side slide door. Applies only to: high-rise buildings, A/E/I occupancies, State-owned buildings, residential care homes, hotels, motels, apartments and condominiums. 2. Elevator in buildings more than two stories or buildings where disabled access is required to upper level(s): 68" by 54", with a minimum clear door width of 36". 3. Elevators other than in (b) above serving less than 50 occupants shall have a minimum inside platfora of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches. b. Raised Braille markings and Arabic numerals are required on control buttons and door jambs. 2-5103(d.l) „ ...... SAHHARI FAdLHIES 11. TOILET FACILITIES ACCESS a. When located on accessible floors, sanitary facilities shall be made accessible to physically handicapped. (2-511.l(a)) b. Doorways shall have 32" mininum clear opening vidth. 2-511.1 c. There shall be a level area with 60" clear depth in the direction of the door suing, and a level area with 44" clear depth in opposite direction of door swing. 2-511.l(a) 12. MULTIPLE ACCOMMODATION TOILET FACILITIES a. Provide clear area 60" high - or clear space 56" high. 2-511.l(a) diameter X 27" x 63" x 27" b. Doors (other than handicap compartment) are not to encroach more than 12" into abo\e nentioned clear space. 2-511 l(a) c Provide a 28" clear space between vater closet and fixture or 32" clear space between water closet and vail. 2-511 l(a) d. A 48" long clear space is required in front of vater closet. A 60" clear space is required vhen, the toilet compartment has a side door. 2-511 l(a) e. Water closet conpartnent door to provide 32" clear width for end entry and 34" clear vidth for side entry. Door to be self-closing. 2-511.l(a) 13. SINGLE ACCOMMODATION TOILET FACILITIES a. Water closet shall be located 28" froa a fixture or 32" from a vail. 2-511 l(a) b. Minimum, clear space in front of vater closet shall be 48". 2-511.l(a) c. In an existing building, a single accommodation toilet facility nay have a space 36" wide x 48 " long in front of vater closet. 2-511.l(a) 14. GRAB BARS A! WATER CLOSET a. One at side 42" long extending 24" in front of vater closet; one at rear 36" long centered on water closet; both mounted 33" above floor. Where a tank- type toilet is used, grab bar may be as high as 36". 2-511.l(a) b. Bars shall be 1-1/4" to 1-1/2" in diameter with 1-1/2" clearance to vail. 2-511.l(a) c. Bar fasteners and mounting support shall be able to withstand 250 Ibs./ft. in bending, shear and tension. 2-511.l(a) 15. WATER CLOSEI a. Height of water closet seat shall be 17" to 19" above floor. 5-1502 b. Controls shall be operable with one hand, and shall not require tight grasping, pinching or twisting of the VTist. 5-1502 c. Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor. 5-1502 d. The force required to activate controls shall be no greater than 5 pounds force. 5-1502 16. URINALS a. Where urinals are provided, the run of at least one shall project 14" from the vail and be located 17" naxinum above floor. 5-1503(a) b. The force required to activate the flush valve shall be 5 Ibs. naximua and located 44" maximum above floor. 5-1503(b) c. Provide 30" x 48" clear floor space for forvard approach. 2-511.l(b) 17. LAVATORIES a. Provide 30" X 48" clear floor space for forvard approach. Said clear floor space cay include knee and toe space under la\atory described below. 2-511 l(b) b. Provide clear space beneath lavatories 29" high by 30" vide by 8" deep at top and 9" high by 30" wide by 17" deep at bottom from front of lavatory (toe space). The maximum counter surface height should be 34". 5-1504(a) c. Hot water and drain pipes lavatories shall be insulated. 5-1504(b) under d. Faucet controls and operating mechamsn (operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 Ibs. 5-1504(c) e. If self-closing valves are used, they shall remain open for at least 10 seconds. 5-1504(c) 18. TOILET ROOM ACCESSORIES a. Mirror bottom edge shall be located 40" maximum above floor. 2-511.l(b) b. Toilet tissue dispensers shall be mounted within 12" from the front edge of toilet seat. 2-511.l(b) c. Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc.) shall be within 40" of floor. 2-511.l(b) 19. SANITARY FACILITIES IDENTIFICATION a. On doorways leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" diameter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color. Unisex facilities shall be identified by the circle with the triangle superimposed within the circle. 2-511.l(a) 20. BATHING FACILITIES a. One such facility shall comply vhen provided for the public, clients or employees 2-511 l(a) b. Shower cocpartnent shall be 42" wide, 148" deep, with a 36" wide entrance. 2-511 l(a) c. Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec. 2-511a-9, 5-1505 and 5-1506, i e., folding seat, flexible shover hose, etc. GENERAL REQOIREKENIS 21. DRINKING FOUNTAIN a. Drinking fountains shall be within alcoves. The alcove shall be not less than 32" wide by 18" deep. 2-511 l(c) b. Wh&n the enforcing agency deternmes that it would create an unreasonable hardship to locate the water fountain in an alcove, the vater fountain Bay project into the path of travel, and the path of travel shall be identifiable to the blind as follows: (1.) The surface of the path of travel at the vater fountain shall be textured so that it is clearly identifiable by a blind person using a cane. The minimum textured area shall extend from the vail supporting the vater fountain to 1 foot beyond the front edge of the vater fountain and shall extend 1 foot beyond each side of the water fountain, or (2.) Wing vails shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the vater fountain to within 6 inches of the surface of the path of travel. Also, there shall be a minimum of 32 inches clear between the wing vails. c. Note on the plans that drinking fountain shall conform to requirements of Sec. 2-511c and 5-1507. 22. PUBLIC TELEPHONE a. Provide space 30" x 48" for forward or parallel approach to telephone. 2-511.l(d) b. Note on the plans that public telephone shall conform to requirements of Sftc. 2-511.l(d). 23. ELECTRICAL REQUIREMENTS a. 15, 20 and 30 amp receptacle outlets shall be installed not less than 12" above floor. 3-210-50(e) b. Center of switches shall be located not less than 36" nor more than 48" above the floor. 3-380-8(c) REQUIREMENTS Where kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc , the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i e., use lever- operated, push-type, etc.). If self- closing valves are used, they shall remain open for at least 10 seconds. 5-1508 GROUP A OCCUPANCY REQOrKEHEKTS AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC. . Seating and toilet facilities for the handicapped shall be accessible from the main lobby or priiaary entrance. 2-611(b) This structure requires vheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(b) Each wheelchair space shall be 60" x 30" and level. 2-611(b) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(b) This structure requires seats for seax-ambulant persons. Clear leg space shall be at least 2-611(b) 2V. Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible. 2-611(b) >IUMS, GRANDSTANDS, BLEACHERS, PAVILIONS,;IUMS This structure requires wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(c) When the seating capacity exceeds 300, the wheelchair spaces shall be m more than one location. 2-611(c) Ticket booths must be accessible from both sides. 2-611(c) Participation areas such as ball courts, exercise rooms, tracks, and clubrooms must be accessible. 2-611(c) Spectator and participant sanitary and locker facilities oust conform to the requirements of Chapter 2-5. 2-611(c) DOCUMENTATION OF UNREASONABLE HARDSHIP - - job Address Plan Check No_ Owner_ Date It is requested that the above named project be granted an exception fromthe requirements of the State of" California Title 24 handicapped accessibility provisions, as specifically noted below: 1. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXEMPTED 2. The cost of all construction without excepted items, is: ._ 3. The impact on financial feasibility of the oro^ect, if the requestedexception is not approved is: • 4. The facility is used by the general public for the purpose of: 5. The exceptions being requested will not penalize handicappedaccessibility as equivalent facilities are available as follows: 6. Exceptions requested, and data provided, by: WAIlhi ADDRESS '• I '1'tJLiJii'ilUNli Department Use Only Findings and Decision of the Enforcing Official: Signature of Enforcing Official Date HA-1 01019CP Date» 3///FV Prepared by« PLAN CHECK NO. BUILDING ADDRESS APPLICANT/CONTACT BUILDING OCCUPANCY Jurisdiction CARLSBAD VALUATION AND PLAN CHECK FEE CQ£/v>QS CT Q Bldg. Dept. D Esgil PHONE NO. DESIGNER PHONE TYPE OF CONSTRUCTION CONTRACTOR PHONE BUILDING PORTION T^- Air Conditioning Commercial Residential Res. or Comm. Fire Sprinklers Total Value BUILDING AREA /Too • VALUATION MULTIPLIER ?-S- @ 9 e VALUE J7^-oo 37 5T?0 Building Permit Fee $_ Plan Check Fee $ COM H E N TS- $ Z./8 7J SHEET OF 12/87 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) DATE TENANT IMPROVEMENT PLAZA CAMINO REAL VILLAGE FAIRE OTHER COMPLETE OFFICE BUILDING 0 / PLANNER DATE ENGINEER DATE C \WP51\FILES\BLDG FRM Rev 11/15/90 Plan Check No. 94- PLANNING CHECKLIST Address Planner VAN LYNCH Phone 438-1161 ext. 4325 (Name) APN Type of Project and Use /M hdI 7^ 7"^ Zone f YY\ Facilities Management Zone CFD Vfet o Legend c c cO O IB (If property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department) Item Complete Item Incomplete - Needs your action 1,2,3 Number in circle indicates plancheck number where deficiency was identified Environmental Review Required: YES DATE OF COMPLETION: TYPE Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval Discretionary Action Required: YES NO TYPE DATE:APPROVAL/RESO. NO. PROJECT NO. * OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval D California Coastal Commission Permit Required: YES _ NO /*^ DATE OF APPROVAL: San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval _ D Inclusionary Housing Fee required. YES NO x\ (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) nn Site Plan: Zoning: Provide a fully dimensioned site plan drawn to scale. Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensioned setbacks and existing topographical lines. Provide legal description of property, and assessor's parcel number Setbacks: Front: Int. Side: Street Side Rear: Lot coverage: 3. Height: 4. Parking: Required Required Required Required Required Required Spaces Required Guest Spaces Required Additional Comments Shown Shown Shown Shown Shown Shown Shown m? Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER PLNCK.FRM City of Carlsbad 94047 Fire Department • Bureau of Prevention Plan Review: Requirements Category: Building Plan Check i Date of Report Friday, March 4,1994 Reviewed by _ Contact Name Dave Petty Address 6650 Flanders Dr Ste J City, State San Diego CA 92121 Bldg Dept No 94-196 Planning No Job Name Viasat Job Address 2290 Cosmos Ste or Bldg No E3 Approved - The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Disapproved - Please see the attached report of deficiencies Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFD Job# 94047 File# 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121 J7a! INTER-ARCH k J SPACE PLANNING • INTERIOR DESIGN March 28, 1994 CITY OF CARTSBAD BUTTDTNG DFPT. 2075 T as Pal mas Drive Carlsbad, California 92008 RF: PFRMTT NO' 94-198 ViaSat 2290 Cosmos Court Carlsbad, Ca 92008 To Whom it may concern: Please be advised that we have changed the stud si7.es shown on our drawings from 3 5/8" to 2 1/2" due to existing wall restrict ions. If you have any questions, please feel free to contact our offices Penne Horn President Pfihme cc: Valerie Agnew, ViaSat INTER ARCH, INC 624 BROADWAY, SUITE 200 SAN DIEGO CALIFORNIA 92101 5402 (619)236-1919 PO BOX 2112 SAN DIEGO CALIFORNIA 92112-2112 FAX (619) 236 9191 R.G.Petty n * t r u r; I i February 24, 1994 City of Carlsbad Building Inspection Dept, 1200 Carlsbad Village Dr, Carlsbad, CA 92008 RE: Signature Authorization To Whom It May Concern: This letter is to give authorization to Rick Corder, Superintendent, to sign in behalf of R.G. Petty Construction for all permit documentation required by your department. If you have any questions, please do not hesitate to give me a call. Sincerely, Dave Petty, Vice-president R.G. Petty Construction DP:mr cc: Rick Corder File General Construction Construction Management 6650 Flanders Drive, Suite J • San Diego, California 92121 • phone (619) 458-9440 • fax (619) 458-0183 fa! INTER-ARCH Ln mJ SPACE PLANNING • INTERIOR DESIGN March 28, 1994 CITY OF CARTSBAD BUTT DTNG DFPT. 2075 T as Pal mas Drive Carlsbad, California 92008 RF-RFRMTT NO- ViaSat Cosmos 94-196 Carlsbad, Ca. 92008 To Whom it may concern• Please be advised that we have changed the stud sizes shown on our drawings from 3 5/8" to 2 1/2" due to existing wall rest rictions. Tf you have any questions, please feel free to contact our off i ces Best Regards, Penne Horn President. PH:me on Valerie Agnew, ViaSat US* INTER ARCH, INC 624 BROADWAY, SUITE 200 SAN DIEGO CALIFORNIA 92101 -5402 (619) 236 1919 PO BOX2112 SANDIEGO CALIFORNIA 92112 2112 FAX (619) 236-9191 J* r r II j i ; > -H1 j i : ! § ° t '• I • ' \ •> ?51 , ' • I a> ! . • ' M ! -1 ' i «j . ' — rH-H- -{— f—j- -t--;- ^_ i • f iIII'1 ;-s1 ' 1 1 1 i 0 Oi i ! i ^ jj ! j • jo d ! ' ';:> I : ir:•' 1 ! 1 ! 1 i i f r ' "1 ! u sCO <^I ^^V^ 1 1 0 > ! : g "° KJK\ 3D "~H\ O^^s. ^,m J \! ,_r »; j."' ,g ro ;Ti T -j, -L > x o 31 m 2 ca ••^— ' "~'i *^~ C^ ' ~' i~., j f — * ^ t j "~^ — -j *-i ^ c_v J .'•/•* ,-— s . • ' ••*" t/J n> r\ \ /™\ i".*~N <•--' —O 'T0.' > ^ c5 o ,. o i~ mm O ;j n o —~ ^ — -^ O —r —«• — ^-^ DJ_ CD 5 5 cr> CQ CQ O 0