HomeMy WebLinkAbout2290 COSMOS CT; ; CB940196; PermitB U I L D I .,N G P E R M I -T
'o3/16/94 ,12:07- =. -.-<- •" -•.—•- \
Page 1 of 1 , - • "'•-" -"" " . C-'~. --
Toh Address- .2290, COSMO5~eT
Permit Type .INDUSTRIAL,. TENANT IMPROVEMENT ^
Parcel No:. 213-050-44-O.f
Va.luation.- 37-, 5 00 , .^t
rfi ^ 7"fc' ~ —Construction ^-- - Reference*
,nT REMODEL OF EXISTING OFFICE AND,
• SHOWER ROOM ,. _,.._^
Permit No CB940196
Project No. A9400280
Deve3.'>pr:f-n!t No
Aool/Ownr - R G .PETTY ,Appl/uwnr. ^^ FLANDE-RS DRIVE,#J
SAN DIEGO^ CA. 92121
619-458-9440
Status ISSUED
Applied 02/24/94
Apr/Issue- 03/16/94
Filtered By. MDP
•*• * *
Fees
Adjustments:
Total Fees.
Fee description
663.00
. 00
663 00
Total Credits:
Total Payments:
Balance Due:
Units . Fee/Unit
00
88 00
575.00
Ext fee Dat'a
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
Enter "Y" for Plumbing Issue Fee >
Each Plumbing Fixture or Trap >
Each Install/Repair Water Line >
* PLUMBING TOTAL
Enter "Y" for Electric Issue Fee >
Enter "Y" for Remodel
* ELECTRICAL TOTAL
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts/Heat Pumps >
Each Exhaust Fan
* MECHANICAL TOTAL
3
1
7.00
7. 00
1
1
9. 00
6. 50
337 00
219.00
8 00
564 00
20.00 Y
21 . 00
7 00
48 00
10 00 Y
10 00 Y
20. 00
15 00 Y
9.00
6 50
31 00
FWAL/APPROVAL
INSP.
CLEARANCE ~ /
CITY OF CARLSBAD
2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161
DJ'LICATION
City of Carlsbad Building Department
2075 Las Palmas Dr.. Carlsbad. CA 92009 (619) 438-1161
1 PERMIT TYPr. j.
A - U Commercial U New Building STTenam Improvement
B - O Industnal D New Building D Tenant Improvement
C - D Residential D Apartment DCondo D Single Family Dwelling D Addition/Alteration
D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing
D Mechanical D Pool D Spa D Retaining Wall D Solar D Other
2. PROJliCT INFORMATION
PLAN CHECK NO.
ESTVAL
PIAN CK DEPOSIT_
VALID BY
DATE
5895 02/24/94 5001 01 02
C-J>T 63-00
FOR OFFICE USE ONLY
Address XJ 3 9 2?
Nearest Cross Street
. uuiluing or suite NO
DtiSCjK.ll 11UIN Subdivision Name/Number Phase No
G 2 Energy Calcs D 2 Structural Calcs D 2 Soils Report D 1 Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE PROPOSED USE
DESCRIPTION OF WORK
SQ FT
NJjJ.diller
/t» #OF STORIES
a UUN1 AL'rPJiK.SUNJjJ.dillerent from applicant)-STV/V/ 6-
NAME
CITY
ADDRESS
STATJE-" C ft- ZIP CODE DAY TELEPHONE
4 ArrLlCAN 1 LON 1 RACI UR
CITY f5 O
5 HHUi'iiKTY UWNKK
STATE
FOR LUN 1 RAL, 1UR LJUWNhR LJAOhNl FUR UWNhR
ADDRESS
ZIP CODE DAY TELEPHONE
NAME
CITY STATE
ADDRESS
ZIP CODE DAY TELEPHONE
6 CONTRACHJK
NAME f>
CITY
ADDRESS
ZIP CODE
LICENSE CLASS
DAY TELEPHONE
CITY BUSINESS LIC # 1 *f %
CITY STATE C/*?" ZIP CODE STATE LIC #.
Workers' Compensation Declaration I hereby allirm that I have a certlticate of consent to self-insure issued Dy the Director ot Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab C)
INSURANCE COMPANY "P f POLICY NO H *•/ §3 V^'?3EXP1RAT10N DATEH *•/§
sr whicCertificate ot hxemption I certify that in the perlormance ol the work lor
so as to become subject to the Workers' Compensation Laws of California
ich this permit is issued, I shall not employ any person'm any manner
SIGNATURE DATE
8 (JWNl'.K-BULLL>hH DFjULAHAUON
Owner-Builder Declaration I hereby attirm that 1 am exempt trom the Contractors License Law tor the tollowing reason
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale )
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions
Code The Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law)
D I am exempt under Section Business and Professions Code for this reason
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500])
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
O YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
D YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
D YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
9 (JUNi>IKU(Jll(JN Ll'lNIJINti AtiKNCJY " "
1 hereby allirm that there is a construction lending agency lor the perlormance ot the work tor which this permit is issued (.Sec 30970J (Jivil Code)
LENDER'S NAME LENDER'S ADDRESS
10 APPUCJANl
l certify mat i nave read tne application and state that the above inlormation is correct I agree to comply with all City ordinances and State laws
relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS
AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSIIA. An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height
Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code)
APPLICANTS SIGNATURE DATE
C WHITE: File YELLO;
W^iphcant PINK. Finance
DEPT: BUILDING
FINAL BUILDING INSPECTION
ENGINEERING {FJBIU? PLANNING U/M
PLAN CHECK#: CB940196
PERMIT#: CB940196
PROJECT NAME: REMODEL OF EXISTING OFFICE AND
SHOWER ROOM
ADDRESS:
CONTACT PERS ON/ PHONE #: MH/ DAVE/4 58 -94 40
SEWER DIST: CA WATER DIST: CA
RECEIVED APR 2 5
WATER
DATE: 04/22/94
PERMIT TYPE: ITI
INSPECTED
BY:
INSPECTED
BY:
INSPECTED
BY:
DATE
INSPECTED:
DATE
INSPECTED:
DATE
INSPECTED:
APPROVED
APPROVED
APPROVED
DISAPPROVED
DISAPPROVED
DISAPPROVED
COMMENTS:
c- CITY OF CARLSBAD
INSPECTION REQUEST
PERMITS CB940196 FOR 04/22/94
DESCRIPTION: REMODEL OF EXISTING OFFICE AND
SHOWER ROOM
TYPE: ITI
JOB ADDRESS: 2290 COSMOS CT
APPLICANT:
CONTRACTOR:
OWNER:
2290
R.G. PETTY PHONE:
JPHONE:
' PHONE:
STE:
619 45
INSPECTOR AREA TP
PLANCKtf CB940196
OCC GRP* B-2
TYPE VN
LOT:
REMARKS: MH/DAVE/458-9440
SPECIAL INSTRUCT:
INSPECTOR
TOTAL TIME:
CD LVL DESCRIPTION
19
29
39
49
ACT COMMENTS
ST
PL
EL
ME
Final
Final
Final
Final
Structural /H T
Plumbing /
Electrical \
Mechanical /
*
***** INSPECTION HISTORY *****
DATE DESCRIPTION
041194 Frame/Steel/Bolting/Welding
041194 Rough Electric
041194 Rough/Ducts/Dampers
040894 Frame/Steel/Bolting/Welding
040794 Frame/Steel/Bolting/Welding
040494 Exterior Lath/Drywall
040494 Frame/Steel/Bolting/Welding
033194 Frame/Steel/Bolting/Welding
033194 Rough/Topout
033194 Rough Electric
033194 Rough Electric
033094 Frame/Steel/Bolting/Welding
033094 Rough/Topout
033094 Rough Electric
033094 Rough/Ducts/Dampers
032994 Frame/Steel/Bolting/Welding
032994 Rough/Topout
032994 Rough Electric
032494 Frame/Steel/Bolting/Welding
032494 Rough/Topout
032494 Rough Electric
031894 Underground/Under Floor
031794 Underground/Under Floor
ACT
AP
AP
AP
NS
CO
AP
AP
PA
AP
AP
AP
NR
AP
PA
AP
AP
AP
AP
CO
CO
CO
AP
NR
INSP
TP
TP
TP
PD
TP
TP
TP
TP
TP
TP
44
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
PK
PK
COMMENTS
T-BAR EXISTING
CEILING LIGHTS RELOCATED
EXISTING
SEE JOB CARD
SHOWERS
ND STRAPING VERT,SHOWER RM
SHOWER RM
SHOWER RM
SHOWER RM
SAMR CORR
SHOWER STALLS
CEILING WIRING
DUCTS,FANS
N/INCL SHOWERS
WALLS,N/INCL SHOWERS
SEE JOB CARD
OK TO POUR CONCRETE
NO PLANS/NO SUPT ON JOB
1\\TS
B ADDRESS
INSPECTION
INSPECTOR
PLANCK
AURIVE:TIME LEAVE
LVL DESCRIPTION ACT COIUIENTS
PEl^tlTS
6/13/09
BB2SQO
CHANGE OF ADDRESS
NOTIFICATION
NEW ADDRESS 2290 COSHOS CT
NEW PHONE NO.438-8099
NAME OF BUSINESS VIA SAT
TYPE OF BUSINESS RESEARCH
OWNER'S NAME MARK DAMKBERG
OLD ADDRESS.G120 PASEO DEL KO&T2 J2
OLD PHONE NO 438-8099
REMARKS
DATE
APPROVAL.
WHITE Finance GREEN Planning CANARY Redevelopment PINK Building GOLDENROD Fire
ESGIL CORPORATION
9320 CHESAPEAKE DR , SUITE 208
SAN DIEGO, CA 92123
(619) 560-14^8
f APPLICANT
JURISDICTION. . CA^LSg/ti3 LjPLV< CHECKER
i~?ILE COPY
?T.SN CHECK NO 1V-JK SET: JL Gb?S
[JDESICA'ER
PROJECT ADDRESS: ^2*/O COSMOS CT
PROJECT NAME:
The plars transmitted nerewitn have been corrected where
necessar_. and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the ;insdiction's building codes when minor deficien-
cies ider.ified OAJ Tfte, rt-TTflcffg.p SH-e£~r =re resolved and
checked ry ouilding department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resuo-itted for a complete recheck.
The chec< list transmitted herewith is for your information.
The plars are being held at Esgil Corp. until corrected
plans are submitted for recheck.
Ii The applicant's copy of the check list is enclosed for the
'—' jurisdiction to return to the applicant contact person.
-The applicant's copy of the check list has been sent to:
j|^} Esgil stsff did not advise the applicant contact person that
plan chec< has been completed.
[] Esgil staff did advise applicant that the plan check has
Vifson f/~\rr — 1 o<- o/^ 'Dover^n /•• /~i nt- = r- *• a A »been coirrleted. Person contacted:
Date contacted: Telephone §
REMARKS:
By: "c7~£ P/SCH*£j^ Enclosures
ESGIL CORPORATION j/6
DGA L:M DPC
zr
/VOTE-.Tf4-£gr /IT T~H-€
o-C-A /3
/IT
THf Ul 6 f+T TD T?fe CvC '..So
»'THw Z-
ESGIL CORPORATION
9320 CHESAPEAKE DR , SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: I// /? V
JURISDICTION: _ CARLSBAD _ <--QPLAN CHECKER
QFILE COPY
PLAN CHECK NO: 7 V~ tf4> _ SET: -3T _ QUPS
QDESIGNER
PROJECT ADDRESS; 2.2-^Q ~
PROJECT NAME:
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
-, The plans transmitted herewith will substantially comply
J with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
D The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
DA (/£-
^6 SO FLANDERS QtZ~ SviTZ. X, SA*> D/£6O
Esgil staff did not advise the applicant contact person that
plan check has been completed.
II Esgil staff did advise applicant that the plan check has
— been completed. Person contacted:
Date contacted: Telephone I
REMARKS:
By; P£.TE FlSCH^J^ Enclosures:
ESGIL CORPORATION
M!GA DCM (D PC
PLAN CORRECTION SHEET
TENANT IMPROVEMENT
PLAN CHECK NO.: IJ~ /9b Date plans received by jurisdiction:
JURISDICTION; CARLSBAD .
Date plans received by Esgil Corporation.
TO:
Date initial plan check completed.
3///?y Bv
PROJECT DATA Applicant contact person:
OCCUPANCY: £^ Tel.
BUILDING USE:
FOREWORD; PLEASE READ
TYPE OF CONSIRPCnON; ^3ZT/J SPK^
Plan check is limited to technical requirements
ACTUAL AREA: T^T <* I5~OO contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
ALLOWABLE AREA: <v/O C^MA/6£ Electrical Code and state laws regulating energy
t, H conservation, noise attenuation and access for the
STORIES: handicapped The plan check is based on
regulations enforced by the Building Inspection
HEIGHT: * J; Department. You may have other corrections based
on laws and ordinances enforced by the Planning
SPRINKLERS: TS-S Department, Engineering Department, Fire Department
or other departments. Code sections cited are
OCCDPANT LOAD; ~T3" - /5~ based on the 1991 UBC.
Tt>7>H- A*-£4- •£ 3~7O The circled items listed need clarification,
modification or change. All items must be
REMARKS: satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1991 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, note on this list
(or a copy) where each correction item has been
addressed, i e.. plan sheet, specification, etc.
Be sure to enclose the marked up list when you
submit the revised plans.
NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED.
LIST NO. 41 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1991 UBC
Please nake all corrections on the original
tracings and submit two new sets of prints, to
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, CA 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints, to.
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(d).
Each sheet of the plans must be signed by the
person responsible for their preparation, even
though there are no structural changes.
Business and Professions Code.
Plans and calculations shall be signed by the
California state licensed engineer or architect
where there are structural changes to existing
buildings or structural additions. Please
include the California license number, seal,
date of license expiration and date plans are
signed. Business and Professions Code.
Provide the correct address and suite number of
tenant space on the plans. Section 302(d).
Provide a note on the site plan indicating the
previous use of the tenant space or building
being remodeled. Section 302.
When the character of the occupancy or use
changes within a building, the building must be
made to comply with current Building Code
requirements for the new occupancy. Please
provide complete details to show the building
with comply. Section 502.
UBC Section 304 requires the Building Official
to determine the total value of all
construction work proposed under this permit.
The value shall include all finish work,
painting, roofing, electrical, plumbing,
heating, air conditioning, elevator, fire
extinguishing systems and any other permanent
equipment. Please provide a signed copy of the
designer's or contractor's construction cost
estimate of all work proposed.
Provide a plot plan showing the distance from
the building to the property lines and the
location of tenant space (or remodel) within
the building.
X
/•
On the first sheet of the plans indicate-
Type of construction of the existing building,
present and proposed occupancy classifications
of the remodel area and the occupant load of
the remodel areas and the floor v,here the
tenant improvement is located
Provide a note on the plans indicating if any
hazardous materials will be stored and/or used
within the building which exceed the
quantities listed in UBC Tables 9-A and 9-B
A complete description of the activities rind
processes that v.ill occur in this tenant space
should be provided. A listing of all
hazardous materials should be included The
materials listing should be stated in a form
that would make classification in Tables 9-A
and 9-B possible. The building official may
require a technical report to identify and
develop nethods of protection from hazardous
materials. Section 901(f).
If control areas are used for exceeding the
exempt amounts of hazardous materials from
Tables 9-A and 9-B, they shall be constructed
of not less that required for a one-hour
occupancy separation. Section 404.
The number of control areas within a building
used for retail/wholesale stores shall not
exceed two; the number of control areas in
buildings with other uses shall not exceed
four. Footnote 1, Tables 9-A and 9-B.
The aggregate quantity of any hazardous
materials "in use" and "in storage" shall not
exceed the quantity listed in Tables 9-A and
9-B for "storage". Footnotes 2 and 3, Tables
9-A and 9-B.
Provide a statement on the Title Sheet of the
plans that this project shall comply with
Title 24 and 1991 UBC, UMC and UPC and 1990
NEC. "
Provide a fully dimensioned floor plan showing
the size and use of all rooms or areas within
the space being improved or altered. Draw the
plans to scale and indicate the scale on the
plan. Section 302(d).
Indicate the use of all spaces adjacent to the
area being remodeled or improved.
Show any existing fire rated area separation
walls, occupancy separation walls, demising
walls, shafts or rated corridors. Identify
and provide construction details for proposed
new fire rated walls.
Specify on the plans the fire ratings of
assemblies to protect penetrations or proposed
openings in existing or new fire walls, floor-
ceiling assemblies or roof-ceiling assemblies.
8/4/92
a/.
Identify existing walls to be removed,
existing walls to remain and proposed new
walls. Identify bearing walls, non-bearing
walls, and shear walls.
Show safety glazing in the following
locations, per Section 5406(d):
a. Where the nearest edge of glazing is
within a 24-inch arc of either side of a
door in a closed postion (unless there is
an intervening v.all between the door and
the glazing or if the glazing is 5'-0" or
higher above the valking surface).
b Glazing greater than 9 square feet with
the bottom edge less than 18" above the
floor and the top edge greater than 36"
above the floor (unless the glazing is
more than 36" horizontally away from
walking surfaces or if a complying
protective bar is installed).
c Glazing in shower and tub enclosures
(including windows within 5 feet of tub
or shower floor).
Provide a section view of all new interior
partitions. Show.
(a) Type, size and spacing of studs. Indicate
gauge for metal studs. Specify
manufacturer and approval number or
indicate "to be ICBO approved".
(b) Method of attaching top and bottom plates
to structure. (NOTE: Top of partition
must be secured to roof or floor framing,
unless suspended ceiling has been designed
for partition lateral load).
(c) Wall sheathing material and details of
attachment (size and spacing of
fasteners).
(d) Show height of partition and suspended
ceiling, and height from floor to roof
framing or floor framing.
Provide notes and/or details to show that the
floor and wall finish in toilet rooms are
surfaced with a smooth hard non-absorbent
material extending five inches up the wall.
Similar surfacing shall be provided on the
walls from the floor to a height of 4 feet
around urinals and within water closet
compartments. Section 510(b).
Note on the plans: "All interior finishes must
comply with Chapter 42 of the UBC". Specify
"Class flame spread rating (minimum)
for ."
27.) Note on plan that suspended ceilings shall
comply with UBC Tables 47-A and 23-P.
In buildings having floors and roofs of wood
frame construction, other than dwelling or
hotel occupancies, draft stop the area between
the ceiling and floor a*pove so that no
concealed space exceeds 1,000 s.f. and no
horizontal dimension exceeds 60 L.F. (if space
has sprinklers, then 3,000 s.f. and 100 L.F.).
Section 2516(f).
In buildings having floors and roofs of wood
frame construction, other than dwelling or
hotel occupancies, draft stop the area between
the ceiling and roof above so that no
concealed space exceeds 3,000 s.f. and no
horizontal dimension exceeds 60 L.F. (if space
has sprinklers, then 9,000 s.f. and 100 L F ).
Section 2516(f).
Storage areas exceeding 1000 sq. ft. in
connection with wholesale or retail sales
shall be separated from the public area by a
one-hour occupancy separation. If the entire
building has an autonatic sprinkler system,
then the occupancy separation need not be
provided Section 702(c)
An automatic sprinkler system shall be
installed in rooms used by the occupants for
the consumption of alcohol and in accessory
uses where the total area of such unseparated
rooms and assembly uses exceeds 5000 square
feet Section 3802(c).
The tenant space and new and/or existing
facilities serving the remodeled area must be
accessible to and functional for the
physically disabled. See the attached
correction sheet. Title 24, Part 2.
The width of the required level area on the
side into which doors swing shall extend 24
inches past the strike edge for exterior doors
and 18 inches past the strike edge for
interior doors. Section 2-3304, Title 24.
Specify lever-type hardware for passage doors
on floors accessible to the disabled. Section
2-3304, Title 24.
If both sexes will be employed and the number
of employees exceeds four, provide separate
toilet facilities for men and women. If "both
sexes will be employed and the total number of
employees will not exceed four", and only one
restroom is provided, note the words in
quotation above on the floor plan.
705(c).
Section
3/. A
required between
the
_-hour occupancy separation is
_occupancy and
_occupancy. Table 5-B.
Ducts penetrating occupancy or area separation
walls must have fire dampers. Section 4306
(J).
In areas where the occupant load exceeds ,
two exits are required. See
. Table 33-A.
Provide an exit analysis plan (may be 8 1/2" x
11" or any convenient size).
Exits should have a minimum separation of one-
half the maximum overall diagonal dimension of
the building or area served. Section 3303(c).
.7/8/92
-The maximum number of required exits and their
required separation must be maintained until
egress is provided from the structure. Section
3303(a).
Rooms with more than 10 occupants may have one
exit through one adjoining room. Revise exits
to comply. Section 3303(e).
Exit signs are required whenever two exits are
required. Show all required exit sign
locations Section 3314 (a).
Show that exits are lighted with at least one
foot candle at floor level. Section 3313(a)
Show the locations of existing exits from the
building and show the path of travel from the
remodel area to the existing exits.
Note on the plans: "All exits are to be
openable from inside without the use of a key
or special knowledge". In lieu of the above,
in a Group B occupancy, you may note "Provide a
sign on or near the exit doors reading THIS
DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS".
This signage is only allowed at the main exit.
Section 3304(c).
Exit doors should be a minimum size of 3 feet
by 6 feet 8 inches with a minimum door swing of
90 degrees. Maximum leaf width is 4 feet.
Section 3304(f).
Exit doors should swing in the direction of
egress when serving an occupant load of 50 or
more or when serving any hazardous area.
Section 3304(b). Applies to door(s)
Regardless of occupant load, a floor or landing
not more than 1/2 inch below the threshold is
required on each side of an exit door used for
disabled access (may be 1" maximum where not
used for disabled access). Section 3304(i).
Doors should not project more than 7 inches
into the required corridor width when fully
opened, nor more than one-half of the required
corridor width when in any position. Section
3305(d).
Revolving, sliding and overhead doors are not
permitted a.s exit doors if the occupant load
exceeds 9 or the exit door serves a hazardous
area. Section 3304(h).
Provide panic hardware in Group A,E,H-l,H-2,H-3
and I occupancies. Chapter 33.
Double acting doors are not allowed when
serving a tributary occupant load of more than
100, or when part of a fire assembly, or part
of smoke and draft control assemblies or when
equipped with panic hardware. Section
3304(b).
¥•
Corridors must provide continuous protection
to the exterior of the building.
Interruptions by an intervening room is not
permitted. Foyers, lobbies or reception rooms
constructed as required for corridors are not
considered intervening rooms. Section 3305.
Corridors and exterior exit balconies serving
10 or more occupants must be a minimum 44
inches vide and 7 feet high to the lowest
projection. Corridors serving less than 50
occupants may be a minimum of 36 inches in
width. Section 3305(b).
When two exits are required, dead end
corridors and exit balconies are limited to 20
feet. Section 3305(e).
Corridors serving 30 or nore occupants shall
have v,alls and ceilings of one-hour
construction Show compliance or clearly show
on plans which of the following exceptions has
been satisfied:
a. Corridors greater than 30 feet wide vhen
the occupants have an exit independent
from the corridor.
b. Exterior sides of exterior exit
balconies.
c. Corridor walls and ceilings need not be
of fire-resistive construction within
office spaces having an occupant load of
100 or less when the entire story in
which the space is located is equipped
with an automatic sprinkler system
throughout and smoke detectors are
installed within the corridor in
accordance with their listing.
d. Within office spaces occupied by a single
tenant, partial height partitions which
form corridors and which do not exceed 6
feet in height need not be fire
resistive, provided they are constructed
in accordance with Section 1705 and are
not more than three fourths of the floor-
to-ceiling height. Section 3305 (g).
Section 3305(g), Exception 5, cannot be used
for non-rated corridors in a fully sprinklered
office space if the occupant load in the space
exceeds 100.
Section 3305(g), Exception 5 does not apply to
common corridors where the corridor serves as
an exit for non-office areas (manufacturing,
warehouse, etc.).
Section 3305(g), Exception 5 is applicable
only for corridors on one floor; the corridors
on the lower level(s) must be rated if these
lower corridors have openings into them from
other levels.
5/28/92
yf.If non-rated corridors are used per Section
3305(g), Exc. 5, provide a reference to the
corridors on the floor plan, noting:
1. Corridors are non-rated per Section
3305(g), Exception 5.
2. Smoke detectors shall be maximum 30' on
center.
3 Power supply shall be dedicated branch
circuit. Circuit disconnecting means
shall be accessible only to authorized
personnel and shall be clearly marked FIRE
ALARM CIRCUIT CONTROL, with a lock-on
device.
If a tenant space utilizes Section 3305(g),
Exception 5, then that tenant space shall be
separated from adjacent spaces by a demising
vail constructed as for a one-hour corridor
wall.
Clearly show vhere the non-rated corridor
system terminates and a rated corridor system
commences.
One-hour fire-rated corridors shall have
interior door openings protected by tight-
fitting smoke and draft control assemblies
rated 20 minutes, except openings in interior
walls of exterior exit balconies. Doors shall
be maintained self-closing or be automatic-
closing by action of a smoke detector per
Section 4306(b). Doors shall be gasketed to
provide a smoke and draft seal where the door
meets the stop on sides and top. Section
3305(h). poO/2J 1,7,8,1,!OeiZ.t 1}
Total area of all openings, except doors, in
any portion of an interior corridor, shall not
exceed 25 percent of the area of the corridor
wall of the room which it is separating from
the corridor. Such openings shall be protected
by fixed glazing listed and labeled for a fire-
protection rating of at least 3/4-hour.
Section 3305(h).
Show rated corridors, lobbies, reception or
foyers cross-hatched on the floor plans.
Provide a complete architectural section of
the corridor, or exterior exit balcony,
showing all fire-resistive materials and
details of construction for all floors, walls,
ceiling and all penetrations. Section
3305(g).
Show the location of fire dampers. Provide
fire dampers at duct penetrations of fire-
rated occupancy and area separations, shafts
and corridor ceilings. Combination fire/smoke
dampers are required at duct penetrations of
rated corridor vails. Section 4306(j).
A/e>u_/At-CS AT
71} 5 a. AT
iz.
10.
A- /
If a room with an exhaust fan has a door
opening into a rated corridor, show how make-
up air will be provided to the room. The door
cannot be undercut, nor can a louver in the
door be provided. Section 3305(h)l.
If building exceeds two stories and has an
elevator opening into a rated corridor, show
how the smoke and draft control provision of
Section 3305(h) will be met. Either provide a
separated elevator lobby or a second door at
the elevator entry meeting the provision.
Section 3305(j).
If a second door is provided at the elevator
entry, note that it will be readily openable
from the car side vithout a key, tool or
special knowledge or effort Section 5106.
New provisions in Chapter 43 of the 1991 UBC
require special treatment of penetrations at
fire-resistive assemblies. Provide typical
details on the plans shoving how the fire-
resistive integrity will be maintained at the
following conditions (Include the
names and ICBO numbers (or
equal) for any sealant):
A. THROUGH-PENETRATIONS (through the entire
assembly):
1. Fire-resistive bearing vails and/or
walls requiring protected openings shall
have penetrations protected with through-
penetration fire stops having an F-
rating, T-rating or complying with UBC
Standard 43-1, depending on their
locations, sizes and combustibility.
2. Fire resistive floor/ceiling assemblies
shall have penetrations protected with
through-penetration fire stops having and
F-rating, T-rating or complying vitn UBC
Standard 43-1, depending on their sizes,
combustibility and whether the
penetrations are in walls above.
B. MEMBRANE-PENETRATIONS (through only one
side of an assembly):
1. Fire-resistive walls (whether bearing or
not and whether requiring fire protected
openings or not) shall have penetrations
protected with membrane-penetration fire
stops having an F-rating or complying
with UBC Standard 43-1, depending on
their size and combustibility. Limited
steel electrical outlet boxes (not
exceeding 16 sq. in., nor more than 100
sq. in. for any 100 sq. ft. of wall)
require no protection.
2. Fire-resistive ceilings shall have no
penetrations, except for noncombustible
sprinkler pipes and steel electrical
outlet boxes as described above.
NOTE: The plans should indicate the various
fire-stop ratings required for all
penetrations.
Provide a note on the plans stating
"Penetrations of fire-resistive walls, floor-
ceilings and roof-ceilings shall be protected
as required in UBC Sections 4304 and 4305".
8/4/92
letu.All roof-mounted equipment shall be concealed
from view. Provide structural detailing for
the screening.
HTSGELLAKKJOS
x N(105/Please see additional corrections or remarks
that follow.
To speed up the recheck process, note on this
list (or a copy) where each correction iten has
been addressed, i e , plan sheet, note or
detail number, calculation page, etc
rlQ7.) Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list If there are other
changes, please briefly describe then and where
they are located in the plans.
Have changes been made to the plans not
resulting fron this correction list' Please
check.
Yes NO
The jurisdiction has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone nunber
of 619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact _
_ P&71L F/KtfcA^ _ at Esgil
Corporation
Thank you.
Enclosures:
1. _
2. _ _
3 _
6/25/93
MECHANICAL, PLUMBING, ENERGY
PLAN CORRECTION SHEE1
JURISDICTION:DATE:~~ '
PLAN CHECK NOHBER:V "" ' ^
GLEN ADAHEK
PLAN CHECKER:
D
/_ i <z &-r' «j c. ( £ r e -
C? /^
To
o o *^t- S
o
ty r
fC.tr
dels are valued over $79,119 and specific0e0)^t
c0)x;s:quirements cannot be metLaw allows equivalent facilities to beted if strict compliance with theations would create an unreasonablehips cannot be waived unless there arecu a-n 01
^
01
Olcuuu(0
0)sz
EH
rH
CUuu(C
3 73Ol InOJ (0
rH XI
01
uu
CN cal or legal barriers that preventding either full access compliance oralent facilitation compliance. When boths and equivalent facilitation are waivedle enforcement official, ratification isH
01
X!a
H >
> HO 3
rH D1a <u
Ol "-H.0) "u0 >,(0 XI
T3
(0o03
01
rH(0
(1)a
c(0
XI
73(U
rH
rl
3<u
rH
CO
O Q, flJ U MH t-i
?-S?oicuE
8S^
01
o
in CU
?«e
rlXI O
w ^.H
<0 Ol <0 OJ
3 C... O Ol Oow5S
C^rHS,
S35-S
3 =
(U XI
> rH 4J 01 JJ OO3rlOrH
-73 rH
.U rH O
H rH 3 01
3 H (U
u
m
C
OH
•a<0
co w en
iJ % CU
S^ci«5§ n-g
°^ s.*2&o q c^3 £ci aco y 3
EH P U25 £ uM
Wa
*~fcacn
cocowoCJ •ations, s:nts and orH >(0 O
rH01 a
O (0c c
rH (U— 4J
cu73
no
73
rH
H&0)
VH
isCU
UC
10
H
rH
I"Ou to remodeledpsCUVH(0
T3<L>
rH
CU
T)O
cu
rH
O.u
CUoc s01 (0 0) rH Hu
01cn ^cu Ou Cnu cx:
(0 H iJ
73 (0
C 01 <0
rH 73 Oi 4
.id 01 )H 01rH j<: (0 xi a
(0 rH N In ECU (0 (0 3 <0 •
S K CJ PS 1
(0 X) O 73 <U 'unary entiEntranceExit Docrl rH 05 X)
05C
rl
S 01
iH
(0
01
73 CU
0) C
rH O
<UX!73 ftO OJ
<U OJIH JJ
01
S-o> c
SH <0CUcn
« C2 5%f(0 10
73>iCncu
(0 H (U
C H
CO
CU H C
•H JH <U
lit
73a cuH rHx: H
OT <4H
73 <u 73
rH 5 rH<u cu'
^•gQ i—I
3O
XI 01
<u
h «a a
03 V-l <U
•O
0) O
(U (Q r
3 >
(U CJ
<V
TITLE 24 HANDICAPPED ACCESS CORRECTION LIST
Jurisdiction
Plan Check No.
References to section numbers v,ith prefix "2" are to Title 24, California Code of Regulations, Part 2
(California Building Code). Prefix "3" is for Part 3 (California Electrical Code). Prefix "5" is for
Part 5 (California Plunbing Code).
Exemptions clamed for any item shall be requested in writing and shall include all data needed to
determine "unreasonable hardship" as described in Section 2-422.
SITE DEVELOPMENT
1. HANDICAPPED PARKING SPACES
a. Provide _handicapped spaces.
2-7102(b)
b Space shall be so located that
handicapped persons are not compelled to
wheel or valk behind parked cars other
than his/her own. 2-7102(c)
c. Parking space shall be a minimum of 9
ft.xlS ft. with adjacent marked 5 ft.
loading zone. Double space shall be 23
ft. wide. Where a single space is
provided, the loading/unloading zone
shall be on the passenger side of the
vehicle. 2-7102(c).
d. Maximum slope of parking surface in any
direction shall not exceed 1/4" per
foot. 2-7102(e).
e. Parking space(s) shall be identified
with the International Symbol of
Accessibility on reflectorized sign
affixed to post or wall, and also
duplicated on parking surface (symbol to
be 36"x36" and painted at the back of
the parking stall). 2-7102(f)
f. Entrance to parking area (or at each
stall) shall have a sign stating that
unauthorized vehicle(s) parking in
handicapped space(s) may be subject to
tow-away. 2-7102(f)
g. If covered parking is provided, then a
reasonable portion of the total number
of stalls reserved for the disabled
shall also be covered. 2-7102(a)
h. Entrances to and vertical clearances
within accessible levels of parking
structures shall be 8 ft. 2 in. to anystructural member, duct or pipe.
2-7102(g)
2. CURB RAMPS
a. Curb ramps shall be located wherever
pedestrian path crosses curb. (2-
7103(a))
b. Curb ramp shall be 48" min. width (2-
7103(b)) with maximum slope of 1 in 12.
2-7103(d)
c. A level 48" mm. depth landing is
required at top of curb ramps over
entire curb ramp width. 2-7103(d)
d. If no landing is provided, the slope of
flared sides shall not exceed 1 in 12.
2-7103(d)
e. Surface is to be slip
contrasting finish
sidewalk. 2-7103(f)
resistant and a
from adjacent
f. Border markings shall be 12" wide of
l/4nxl/4" grooves, 3/4" apart, located at
top and sides. 2-7103(h)
3. WALKS
a. Site development and grading shall be
designed to provide access to primary
entrances and access to normal paths of
travel and where necessary to provide
access shall incorporate pedestrian
ramps, curb ramps, etc. 2-7101(a)
b. Walks sloping greater than 5% (1 in 20)
must comply with ramp requirements of
Sec. 2-3307. 2-3325(c)
c. Walk width shall be 48" minimum, and
shall have slip-resistant surfaces.
2-3325(a)
d. The maximum cross slope shall not exceed
1/4" per foot. 2-3325(a)3
e. Gratings are not
possible. 2-3325(b)
allowed whenever
f. At each gate or door a 60"x60" level area
is required when the gate swings toward
the walk. 2-3325(e)
g. A 48"x44" deep level area is required
when the gate swings away from the walk.
2-3325(e)
h. A 24" clear space is required at strike
side of gate or door. 2-3325(e)
4. PEDESTRIAN RAMPS
a. A path of travel with a slope greater
than 1 in 20 shall be considered a ramp.
2-3307(a)
b. The maximum slope shall be 1 in 12.
2-3307(c.l)
c. The width shall be 48" minimum. A
minimum width of 60" is required where a
ramp serves as a primary entrance to
buildings having an occupant load of 300
or more. Group R Occupancies may be 36"
when the occupant load is 50 or less. 2-
3307(b.l)
d. The surface of ramps shall be slip-
resistant. 2-3307(g)
e. A 60" intermediate landing is required
at maximum elevation change of 30" and
72" landing at each change of direction
- - (over 30 degrees). 2-3307(d 1)
f. Landings are required at top and bottoa
of ramps. 2-3307(d 1)
g. Bottom landing shall be raininuin of 72"
in the direction of travel. Fig. 2-33-
11A
h. Top landing shall be 60" x 60" nininua.
2-3307(d.l)
i. When door swings onto top landing,
minimum depth of landing required is
door width plus 42". 2-3307(d 1.)
j. Top landing shall have 60" mm. width
when door swings onto the landing, with
24" on strike side of door at exterior
ramp, or 18" at interior ranp.
2-3307(d 1)
k. Ranp handrails are required on each side
of ramp, when slope exceeds 1 in 15. 2-
3307(e.l)
1. Ramp handrails shall be continuous,
located 30"-34" in height above ranp
surface, with 12" extensions beyond top
and bottom, and the ends returned.
2-3307(e.l)
m. Handrails shall be 1-1/4" to 2" cross
section, spaced minimum of 1-1/2" froo
wall. 2-3307(e.l)
n. A 2" high curb or wheel guide rail
centered 3" + 1" above ramp surface is
required on both sides where not
otherwise bounded by walls when the ramp
-exceeds 10 feet in length.
2-3307(h.l)
5. SPECIAL ACCESS LIFTS
a. Lifts may be provided between levels, in
lieu of elevator, when the vertical
distance between landings, structural
elevator, structural design and
safeguards are as allowed by the State
of California, Department of Industrial
Relations, Division of Occupational
Safety and Health. 2-5107(a)
b. The lift platform shall be of sufficient
size to accommodate a wheelchair
(30"x48"). 2-5107(a)
c. There shall be a level and clear floor
area or landing (60"x60") at each level
for access to the lift. 2-5107(a)
6. HAZARDS
a. Provide 80" headroom from walkvay
surface to any overhanging obstruction.
2-3326(b)
b. Headroom of 80" minimum shall be
maintained for walks, corridors, aisles,
etc. 2-522(f)
c. Protruding objects with leading edges
between 27" and 80" above finished floor
shall not protrude more than 4" into
walks, corridors, etc. 2-522(f)
d. Free standing objects mounted on posts
between 27" and 80" above the floor nay
project a maximum of 12". 2-522(f)
e. Abrupt changes in level exceeding 4"
adjacent to walks, except between walks
and adjacent streets or drives, shall be
identified by 6" high warning curbs abo\e
walk surface. 2-3326(a)
ENTRANCES AND CIRCOLATIOH
7. ENTRANCES, DOORS, VESTIBULES AND CORRIDORS
a. All primary entrances to buildings shall
be accessible to the handicapped.
2-3301(f)
b. All required passage doors shall have 32"
clear opening at 90 degrees (36" door).
2-3304(f)
c. At least one of a pair of doors shall
meet the minimum 32" clear entrance width
requirement. 2-3304(f)
d. Threshold shall be no higher than 1/2"
above the floor. Edge to be beveled with
a slope no greater than 1 in 2, if more
than 1/4". 3304(i.l)
e. Exterior level landing may slope up to
1/4" per . foot in any direction for
surface drainage. 2-413
f. Door hardware shall be of the lever or
push type, mounted 30" to 44" above the
floor and ba operable - with a maximum
effort of 8.5 Ibs. for exterior doors and
5 Ibs. for interior doors. 2-3304(c), 2-
3304(1.2)
g. The lower 10" of the door shall be of
smooth, plane surface (no recess or trap)
except at automatic and sliding doors.
2-3304(i.3)
h. Building entrance(s) shall be identified
by sign with the International Symbol of
Accessibility. Show location on plan.
The symbol shall be a white figure on
blue background. 2-522(b)
i. At turnstile, provide an access gate, 32"
clear width opening, within, 30 feet of
turnstile. 2-3304(1.4)
j. There shall be a clear area, on each side
of door, 60" deep in direction of door
swing and 44" deep in opposite direction
of door swing. 2-3304(1.1)
k. Width of clear area on the swing side of
the door shall extend 24" past strike
jamb for exterior doors and 18" past
strike janb for interior doors.
2-3304(i.l)
1. The space between two consecutive doors
(vestibule) shall provide a mininua of
48" clear depth between the open door
and a second closed door Doors in a
series at a \estibule shall swing in the
same direction, or away froa the space
between them 2-3304(i 1)
n. For corridors over 200 feet long, see
special requirements of Sec. 2-3305(b)2
8. FLOORS
a. Floors of a given story shall be a
coraaon level throughout or shall be
connected by pedestrian ramps, passenger
elevators, or s pecial access lifts.
2-522(e)
9. STAIRWAYS
NOTE: Only applies where disabled access is
provided or required to other levels.
a. Treads shall have smooth, rounded
e>T>osed edges and be slip resistant. 2-
3306(s)
b. Nosirg shall not project more than
1-1/2 inches past face of the riser
below. 2-3306(s)
c. Risers shall be sufficiently solid.
2-3306(s)
d. The upper approach and lower tread of
each flight of stairs shall be marked
with a. contrasting colored strip 2" in
width. 2-3306(r)
e. On exterior stairs, each tread shall be
marked as noted above. 2-3306(r)
f. Handrails are required on each side of
stairway. 2-3306
g. Handrails shall be located 30" to 34"
above nosing,extend 12" beyond top riser
and 12" plus tread width beyond bottom
nosing and returned to wall/newel post.
2-3306(j.l).
h. Handrails shall be 1-1/4" to 2" in
gripping cross section and 1-1/2" clear
of vail. 2-3306(j.l)
i. Approved stairway identification signs
shall be located at each floor level in
all enclosed stairways in buildings two
or more stories in height. The sign
shall identify the stairway, indicate
whether there is roof access, the floor
level, and the upper and lower terninus
of the stairway. The information shall
be presented using raised Arabic minerals
and raised braille synbols which confora
to Section 522(b)3. The sign shall be
located approximately 5 feet above the
floor landing immediately adjacent to the
door on the strike side. Signs shall
cocply \.ith requirements of U.B.C.
Standard No. 33-2.
10 ELEVATORS
a. Provide clear inside elevator car
dimensions as required by U B.C. Section
5103(d) 6 and Title 24 2-5103(d.l).
1. At least one elevator in buildings 4
or more stories in height: 80" by
54", with a 42-inch side slide door.
Applies only to: high-rise buildings,
A/E/I occupancies, State-owned
buildings, residential care homes,
hotels, motels, apartments and
condominiums.
2. Elevator in buildings more than two
stories or buildings where disabled
access is required to upper level(s):
68" by 54", with a minimum clear door
width of 36".
3. Elevators other than in (b) above
serving less than 50 occupants shall
have a minimum inside platfora of 4
feet 6 inches by 4 feet 6 inches and a
minimum clear door width of 36 inches.
b. Raised Braille markings and Arabic
numerals are required on control buttons
and door jambs. 2-5103(d.l) „ ......
SAHHARI FAdLHIES
11. TOILET FACILITIES ACCESS
a. When located on accessible floors,
sanitary facilities shall be made
accessible to physically handicapped.
(2-511.l(a))
b. Doorways shall have 32" mininum clear
opening vidth. 2-511.1
c. There shall be a level area with 60"
clear depth in the direction of the door
suing, and a level area with 44" clear
depth in opposite direction of door
swing. 2-511.l(a)
12. MULTIPLE ACCOMMODATION TOILET FACILITIES
a. Provide clear area 60"
high - or clear space 56"
high. 2-511.l(a)
diameter X 27"
x 63" x 27"
b. Doors (other than handicap compartment)
are not to encroach more than 12" into
abo\e nentioned clear space.
2-511 l(a)
c Provide a 28" clear space between vater
closet and fixture or 32" clear space
between water closet and vail.
2-511 l(a)
d. A 48" long clear space is required in
front of vater closet. A 60" clear
space is required vhen, the toilet
compartment has a side door.
2-511 l(a)
e. Water closet conpartnent door to provide
32" clear width for end entry and 34"
clear vidth for side entry. Door to be
self-closing. 2-511.l(a)
13. SINGLE ACCOMMODATION TOILET FACILITIES
a. Water closet shall be located 28" froa a
fixture or 32" from a vail. 2-511 l(a)
b. Minimum, clear space in front of vater
closet shall be 48". 2-511.l(a)
c. In an existing building, a single
accommodation toilet facility nay have a
space 36" wide x 48 " long in front of
vater closet. 2-511.l(a)
14. GRAB BARS A! WATER CLOSET
a. One at side 42" long extending 24" in
front of vater closet; one at rear 36"
long centered on water closet; both
mounted 33" above floor. Where a tank-
type toilet is used, grab bar may be as
high as 36". 2-511.l(a)
b. Bars shall be 1-1/4" to 1-1/2" in
diameter with 1-1/2" clearance to vail.
2-511.l(a)
c. Bar fasteners and mounting support shall
be able to withstand 250 Ibs./ft. in
bending, shear and tension.
2-511.l(a)
15. WATER CLOSEI
a. Height of water closet seat shall be 17"
to 19" above floor. 5-1502
b. Controls shall be operable with one
hand, and shall not require tight
grasping, pinching or twisting of the
VTist. 5-1502
c. Controls for the flush valves shall be
mounted on the wide side of toilet
areas, no more than 44" above the floor.
5-1502
d. The force required to activate controls
shall be no greater than 5 pounds force.
5-1502
16. URINALS
a. Where urinals are provided, the run of at
least one shall project 14" from the vail
and be located 17" naxinum above floor.
5-1503(a)
b. The force required to activate the flush
valve shall be 5 Ibs. naximua and located
44" maximum above floor.
5-1503(b)
c. Provide 30" x 48" clear floor space for
forvard approach. 2-511.l(b)
17. LAVATORIES
a. Provide 30" X 48" clear floor space for
forvard approach. Said clear floor space
cay include knee and toe space under
la\atory described below.
2-511 l(b)
b. Provide clear space beneath lavatories
29" high by 30" vide by 8" deep at top
and 9" high by 30" wide by 17" deep at
bottom from front of lavatory (toe
space). The maximum counter surface
height should be 34". 5-1504(a)
c. Hot water and drain pipes
lavatories shall be insulated.
5-1504(b)
under
d. Faucet controls and operating mechamsn
(operable with one hand) shall be of the
type not requiring tight grasping,
pinching or twisting of the wrist (such
as lever-operated) and an operating force
not exceeding 5 Ibs. 5-1504(c)
e. If self-closing valves are used, they
shall remain open for at least 10
seconds. 5-1504(c)
18. TOILET ROOM ACCESSORIES
a. Mirror bottom edge shall be located 40"
maximum above floor. 2-511.l(b)
b. Toilet tissue dispensers shall be mounted
within 12" from the front edge of toilet
seat. 2-511.l(b)
c. Operating parts of dispensing and
disposal fixtures (towels, waste, coin
slots, etc.) shall be within 40" of
floor. 2-511.l(b)
19. SANITARY FACILITIES IDENTIFICATION
a. On doorways leading to sanitary
facilities the symbols to be provided are
12" Equilateral triangle for men, 12"
diameter circle for women, and 1/4"
thick, centered on door, 60" high and
contrasting color. Unisex facilities
shall be identified by the circle with
the triangle superimposed within the
circle. 2-511.l(a)
20. BATHING FACILITIES
a. One such facility shall comply vhen
provided for the public, clients or
employees 2-511 l(a)
b. Shower cocpartnent shall be 42" wide,
148" deep, with a 36" wide entrance.
2-511 l(a)
c. Show on the plans that the handicapped
bathing facilities shall conform to
requirements of Sec. 2-511a-9, 5-1505
and 5-1506, i e., folding seat, flexible
shover hose, etc.
GENERAL REQOIREKENIS
21. DRINKING FOUNTAIN
a. Drinking fountains shall be within
alcoves. The alcove shall be not less
than 32" wide by 18" deep. 2-511 l(c)
b. Wh&n the enforcing agency deternmes
that it would create an unreasonable
hardship to locate the water fountain in
an alcove, the vater fountain Bay
project into the path of travel, and the
path of travel shall be identifiable to
the blind as follows:
(1.) The surface of the path of travel
at the vater fountain shall be textured
so that it is clearly identifiable by a
blind person using a cane. The minimum
textured area shall extend from the vail
supporting the vater fountain to 1 foot
beyond the front edge of the vater
fountain and shall extend 1 foot beyond
each side of the water fountain, or
(2.) Wing vails shall be provided on
each side of the water fountain. The
wing walls shall project out from the
supporting wall at least as far as the
vater fountain to within 6 inches of the
surface of the path of travel. Also,
there shall be a minimum of 32 inches
clear between the wing vails.
c. Note on the plans that drinking fountain
shall conform to requirements of
Sec. 2-511c and 5-1507.
22. PUBLIC TELEPHONE
a. Provide space 30" x 48" for forward or
parallel approach to telephone.
2-511.l(d)
b. Note on the plans that public telephone
shall conform to requirements of
Sftc. 2-511.l(d).
23. ELECTRICAL REQUIREMENTS
a. 15, 20 and 30 amp receptacle outlets
shall be installed not less than 12"
above floor. 3-210-50(e)
b. Center of switches shall be located not
less than 36" nor more than 48" above
the floor. 3-380-8(c)
REQUIREMENTS
Where kitchenettes are provided at
employee break rooms, conference areas,
customer lounges, etc , the faucet
controls at kitchen sinks shall be
operable with one hand and shall not
require tight grasping, pinching or
twisting of the wrist (i e., use lever-
operated, push-type, etc.). If self-
closing valves are used, they shall
remain open for at least 10 seconds.
5-1508
GROUP A OCCUPANCY REQOrKEHEKTS
AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC.
. Seating and toilet facilities for the
handicapped shall be accessible from the
main lobby or priiaary entrance.
2-611(b)
This structure requires
vheelchair seating spaces. In theaters
and auditoriums, the seating shall be
provided in a variety of locations so as
to provided a choice of admission prices.
2-611(b)
Each wheelchair space shall be 60" x 30"
and level. 2-611(b)
When the seating capacity exceeds 300,
the wheelchair spaces shall be in more
than one location. 2-611(b)
This structure requires
seats for seax-ambulant persons. Clear
leg space shall be at least
2-611(b)
2V.
Stages, enclosed and unenclosed
platforms, orchestra pits, ticket booths,
and refreshment sales facilities shall be
made accessible. 2-611(b)
>IUMS, GRANDSTANDS, BLEACHERS, PAVILIONS,;IUMS
This structure requires
wheelchair seating spaces. In theaters
and auditoriums, the seating shall be
provided in a variety of locations so as
to provided a choice of admission prices.
2-611(c)
When the seating capacity exceeds 300,
the wheelchair spaces shall be m more
than one location. 2-611(c)
Ticket booths must be accessible from
both sides. 2-611(c)
Participation areas such as ball courts,
exercise rooms, tracks, and clubrooms
must be accessible. 2-611(c)
Spectator and participant sanitary and
locker facilities oust conform to the
requirements of Chapter 2-5.
2-611(c)
DOCUMENTATION OF UNREASONABLE HARDSHIP - -
job Address Plan Check No_
Owner_ Date
It is requested that the above named project be granted an exception fromthe requirements of the State of" California Title 24 handicapped
accessibility provisions, as specifically noted below:
1. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXEMPTED
2. The cost of all construction without excepted items, is: ._
3. The impact on financial feasibility of the oro^ect, if the requestedexception is not approved is:
•
4. The facility is used by the general public for the purpose of:
5. The exceptions being requested will not penalize handicappedaccessibility as equivalent facilities are available as follows:
6. Exceptions requested, and data provided, by:
WAIlhi
ADDRESS
'• I '1'tJLiJii'ilUNli
Department Use Only
Findings and Decision of the Enforcing Official:
Signature of Enforcing Official Date
HA-1 01019CP
Date» 3///FV
Prepared by«
PLAN CHECK NO.
BUILDING ADDRESS
APPLICANT/CONTACT
BUILDING OCCUPANCY
Jurisdiction CARLSBAD
VALUATION AND PLAN CHECK FEE
CQ£/v>QS CT
Q Bldg. Dept.
D Esgil
PHONE NO.
DESIGNER PHONE
TYPE OF CONSTRUCTION CONTRACTOR PHONE
BUILDING PORTION
T^-
Air Conditioning
Commercial
Residential
Res. or Comm.
Fire Sprinklers
Total Value
BUILDING AREA
/Too
•
VALUATION
MULTIPLIER
?-S-
@
9
e
VALUE
J7^-oo
37 5T?0
Building Permit Fee $_
Plan Check Fee $
COM H E N TS-
$ Z./8 7J
SHEET OF
12/87
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
DATE
TENANT IMPROVEMENT
PLAZA CAMINO REAL
VILLAGE FAIRE
OTHER
COMPLETE OFFICE BUILDING
0 /
PLANNER DATE
ENGINEER DATE
C \WP51\FILES\BLDG FRM Rev 11/15/90
Plan Check No. 94-
PLANNING CHECKLIST
Address
Planner VAN LYNCH Phone 438-1161 ext. 4325
(Name)
APN
Type of Project and Use /M hdI 7^ 7"^
Zone f YY\ Facilities Management Zone
CFD
Vfet
o
Legend
c c cO O IB
(If property in, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department)
Item Complete
Item Incomplete - Needs your action
1,2,3 Number in circle indicates plancheck number where deficiency was
identified
Environmental Review Required: YES
DATE OF COMPLETION:
TYPE
Compliance with conditions of approval? If not, state conditions which require action
Conditions of Approval
Discretionary Action Required: YES NO TYPE
DATE:APPROVAL/RESO. NO.
PROJECT NO. *
OTHER RELATED CASES:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
D California Coastal Commission Permit Required: YES _ NO /*^
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval _
D Inclusionary Housing Fee required. YES NO x\
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
nn
Site Plan:
Zoning:
Provide a fully dimensioned site plan drawn to scale. Show North
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
Provide legal description of property, and assessor's parcel number
Setbacks:
Front:
Int. Side:
Street Side
Rear:
Lot coverage:
3. Height:
4. Parking:
Required
Required
Required
Required
Required
Required
Spaces Required
Guest Spaces Required
Additional Comments
Shown
Shown
Shown
Shown
Shown
Shown
Shown m?
Shown
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
PLNCK.FRM
City of Carlsbad 94047
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check
i
Date of Report Friday, March 4,1994 Reviewed by _
Contact Name Dave Petty
Address 6650 Flanders Dr Ste J
City, State San Diego CA 92121
Bldg Dept No 94-196 Planning No
Job Name Viasat
Job Address 2290 Cosmos Ste or Bldg No
E3 Approved - The item you have submitted for review has been approved The approval is
based on plans, information and/or specifications provided in your submittal,
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes Please review carefully all comments attached, as failure
to comply with instructions in this report can result in suspension of permit to
construct or install improvements
D Disapproved - Please see the attached report of deficiencies Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards Submit corrected plans and/or specifications to this
office for review
For Fire Department Use Only
Review 1st 2nd 3rd
Other Agency ID
CFD Job# 94047 File#
2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121
J7a! INTER-ARCH
k J SPACE PLANNING • INTERIOR DESIGN
March 28, 1994
CITY OF CARTSBAD BUTTDTNG DFPT.
2075 T as Pal mas Drive
Carlsbad, California 92008
RF: PFRMTT NO' 94-198
ViaSat
2290 Cosmos Court
Carlsbad, Ca 92008
To Whom it may concern:
Please be advised that we have changed the stud si7.es shown
on our drawings from 3 5/8" to 2 1/2" due to existing wall
restrict ions.
If you have any questions, please feel free to contact our
offices
Penne Horn
President
Pfihme
cc: Valerie Agnew, ViaSat
INTER ARCH, INC 624 BROADWAY, SUITE 200 SAN DIEGO CALIFORNIA 92101 5402 (619)236-1919
PO BOX 2112 SAN DIEGO CALIFORNIA 92112-2112 FAX (619) 236 9191
R.G.Petty
n * t r u r; I i
February 24, 1994
City of Carlsbad
Building Inspection Dept,
1200 Carlsbad Village Dr,
Carlsbad, CA 92008
RE: Signature Authorization
To Whom It May Concern:
This letter is to give authorization to Rick Corder,
Superintendent, to sign in behalf of R.G. Petty Construction for
all permit documentation required by your department.
If you have any questions, please do not hesitate to give me a
call.
Sincerely,
Dave Petty, Vice-president
R.G. Petty Construction
DP:mr
cc: Rick Corder
File
General Construction Construction Management
6650 Flanders Drive, Suite J • San Diego, California 92121 • phone (619) 458-9440 • fax (619) 458-0183
fa! INTER-ARCH
Ln mJ SPACE PLANNING • INTERIOR DESIGN
March 28, 1994
CITY OF CARTSBAD BUTT DTNG DFPT.
2075 T as Pal mas Drive
Carlsbad, California 92008
RF-RFRMTT NO-
ViaSat
Cosmos
94-196
Carlsbad, Ca. 92008
To Whom it may concern•
Please be advised that we have changed the stud sizes shown
on our drawings from 3 5/8" to 2 1/2" due to existing wall
rest rictions.
Tf you have any questions, please feel free to contact our
off i ces
Best Regards,
Penne Horn
President.
PH:me
on Valerie Agnew, ViaSat
US*
INTER ARCH, INC 624 BROADWAY, SUITE 200 SAN DIEGO CALIFORNIA 92101 -5402 (619) 236 1919
PO BOX2112 SANDIEGO CALIFORNIA 92112 2112 FAX (619) 236-9191
J*
r r
II j i ; > -H1 j i : ! § °
t '• I • ' \ •> ?51 , ' • I a>
! . • ' M ! -1 ' i «j . '
— rH-H- -{— f—j- -t--;- ^_
i • f iIII'1 ;-s1 ' 1 1 1 i 0 Oi i ! i ^ jj ! j • jo d
! ' ';:>
I : ir:•' 1 ! 1 ! 1 i i f
r ' "1
!
u
sCO
<^I
^^V^
1 1 0 >
! : g "°
KJK\ 3D
"~H\ O^^s. ^,m J
\! ,_r »; j."' ,g ro ;Ti T -j, -L > x o 31 m 2 ca
••^— ' "~'i *^~ C^ ' ~' i~., j f — * ^ t j "~^ — -j *-i ^ c_v J .'•/•* ,-— s . • ' ••*" t/J n> r\ \ /™\ i".*~N <•--' —O 'T0.'
>
^ c5 o ,. o i~
mm
O
;j
n
o —~ ^ — -^
O —r —«• — ^-^ DJ_ CD 5
5 cr>
CQ
CQ
O
0