HomeMy WebLinkAbout2293 COSMOS CT; ; CB013127; Permit01-08-2002
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB013127
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
2293 COSMOS CT CBAD
Tl Sub Type
2130504500 Lot#
$4,500 00 Construction Type
Reference #
OCEANSIDE TILE & GLASS
ADD CONTAINMENT WALL & 2 DOORS
INDUST
0
NEW
Applicant
RICHARDSON ROBERT
2802 STATE STREET
CARLSBAD CA 92009
760-929-4000
Status ISSUED
Applied 10/01/2001
Entered By JM
Plan Approved 11/05/2001
Issued 01/08/2002
Inspect Area
Owner
AXIOM AIRPORT PARTNERS L P
C/O CHRIS PISARIK
3039 CRESTA WAY 8370 01/08/02 0002 01
LAGUNA BEACH CA 92651 CGP 72-96
Total Fees $17296 Total Payments To Date $100 00 Balance Due $72 96
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$61 19 Meter Size
$0 00 Add'l Reel Water Con Fee
$39 77 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$1 00 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$2700
$2000
$2400
$000
$000
$000
$000
$17296
Inspector ^
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as lees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
1;;: PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK
EST VAL -py
Plan Ck Deposit
Validated
Date
Address (include Bldg/Suite #)Business Name (at this address)
Legal Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor s Parcel #Existing Use Proposed Use
Description of Work
CONTACT
SQ FT #of Stones
ON (if different from applicant)
# of Bedrooms # of Bathrooms
Name Address
Contractor, i JQ Agent for Contractor Q Owner
"
City
gerit for Owner
Name
4/W 'PROPERTY OWNER
Address City State/Zip Tele'phorie #
Name Address City State/Zip Telephone #
S CONTRACTOR COMPANY NAME ; P~'
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its
issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
[Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500])
Name
State License #
Address
License Class
City State/Zip
City Business License #
Telephone #
Designer Name Address City State/Zip Telephone
State License #
:6 .WORKERS'COMPENSATION
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
0 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
Q I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is
issued My worker s compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees
SIGNATURE DATE
7 OWNER BUILDER DECLARATION s
1 hereby affirm that I am exempt from the Contractor s License Law for the following reason
l~l I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is
sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
0***l as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The
Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
[~1 I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O YES QNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work but I hj
of work)
I haxe icontracted (hn IB following persons to provide the work indicated (include name / address / phone number / type
icvv^-v.DATE /- g~PROPERTY OWNER SIGNATURE
COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? fj YES "S^ NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 O YES
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES "^if NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8 , CONSTRUCTION LENDING AGENCY V I -I! >*" -
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code)
LENDER S NAME LENDER S ADDRESS
9 APPLICANT CERTIFICATION * :" ;;:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commepeeti wdthm 180 days^f&rnjhe date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commen/3^pnoj?Q Benpa of IJKKJay^Section 106 4 4 Uniform Building Code)
APPLICANT S SIGNATURE tf ^ 'l/^>/y^l\L^ DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad
Final Building Inspection
Dept Building Engineering
Plan Check*
Permit* CB013127
Project Name OCEANSIDE TILE &
Planning CMWD
GLASS
StLite Fire-'
Date 02/26/2002
Permit Type Tl
Sub Type INDUST
ADD CONTAINMENT WALL & 2 DOORS
Address 2293 COSMOS CT
Contact Person TIM
Sewer Dist CA
Inspected /^ _
Inspected
Bv
Inspected
By
Comments
Phone 7608453003
Water Dist CA
Date / /
Inspected V/^y
Date
Inspected
Date
Inspected
•
Lot 0
Approved *^ Disapproved
Approved Disapproved
Approved Disapproved
• .. . •<
City of Carlsbad Bldg Inspection Request
For 03/01/2002
Permit# CB013127
Title OCEANSIDE TILE & GLASS
Description ADD CONTAINMENT WALL & 2 DOORS
Inspector Assignment TP
Type Tl Sub Type INDUST
Job Address 2293 COSMOS CT
Suite Lot 0
Location
APPLICANT RICHARDSON ROBERT
Owner OCEANSIDE GLASSTILE CO
Remarks
Phone 7608453003
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By TIM
Entered By ROBIN
Act Comments
Associated PCRs
PCR01190 PENDING
Inspection History
Date Description
02/26/2002
02/26/2002
02/26/2002
02/26/2002
02/12/2002
02/06/2002
02/06/2002
02/05/2002
02/04/2002
01/30/2002
19
29
39
49
17
14
17
14
14
14
Final Structural
Final Plumbing
Final Electrical
Final Mechanical
Interior Lath/Drywall
Frame/Steel/Bolting/Weldmg
Interior Lath/Drywall
Frame/Steel/Boltmg/Weldmg
Frame/Steel/Bolting/Welding
Frame/Steel/Boltmg/Welding
Act
CO
we
we
we
AP
we
NR
AP
NR
CO
Insp
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
Comments
TAPE HOLES 1 HR WALL FIRE APVL
WALL NPP
EsGil Corporation
In fartmrsflip With government for 'Buidfing Safety
DATE 11/2/01 g APPLJCANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 01-3127 SET II
PROJECT ADDRESS 2293 Cosmos Ct
PROJECT NAME Oceanside Glasstile TI ( Hazardous Materials Control Area)
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) /^ Fax #
Mail Telephone Fax In Person
REMARKS City to verify that the exisUrfg'buildmg access and rest room facilities comply
with the current disabled access standards (Applicant says building just completed)
By Chuck Mendenhall Enclosures
Esgil Corporation
D GA D MB D EJ D PC 10/29/01 tmsmUdot
EsGil Corporation
In Partners/tip with government for ItuMing Safety
DATE 10/12/01 OAPPLICANT
JURISDICTION Carlsbad apTATTREVlEWER
a FILE
PLAN CHECK NO 01-3127 SET I
PROJECT ADDRESS 2293 Cosmos Ct
PROJECT NAME Oceanside Glasstile TI ( Storage Room)
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Robert Richardson
2802 State St, Suite 'C', Carlsbad, CA 92008
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Robert Richardson Telephone # (760) 434-8400
Date contacted lo-U-°'(by &uu) Fax # C7<fc<5)-f-:b4-e4-cj7>
Mail -^ Telephone ^ Fax «—• In Person
REMARKS
By Chuck Mendenhall Enclosures
Esgil Corporation
D GA n MB n EJ n PC 10/2/01 tmsmUdot
9320 Chesapeake Drive, Suite 208 +• San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
Carlsbad O1-3127
10/12/01
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 01-3127 JURISDICTION Carlsbad
OCCUPANCY SI USE storage
TYPE OF CONSTRUCTION unknown ACTUAL AREA 361
ALLOWABLE FLOOR AREA
SPRINKLERS'? unknown
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED 10/12/01
STORIES
HEIGHT
OCCUPANT LOAD 1
DATE PLANS RECEIVED BY
ESGIL CORPORATION 10/2/01
PLAN REVIEWER Chuck Mendenhall
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 1994 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i e . plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans
LIST NO 40 TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC)tiforw dot
Carlsbad O1-3127
10/12/O1
1 Please make all corrections on the original tracings, as requested in the correction
list
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted
in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, Carlsbad, CA 92009, (760) 602-2721 The
City will route the plans to EsGil Corporation and the Carlsbad Planning,
Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)
560-1468 Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete
2 Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes Business and
Professions Code
3 Provide a statement on the Title Sheet of the plans that this project shall comply
with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC
4 Provide a note on the plans indicating if any hazardous materials will be stored
and/or used within the building which exceed the quantities listed in UBC Tables
3-D and 3-E
5 What is the purpose of the use of fire rated doors'? Why aren't the new walls fire
rated?
6 A complete description of the activities and processes that will occur in this
tenant space should be provided A listing of all hazardous materials should be
included The materials listing should be stated in a form that would make
classification in Tables 3-D and 3-E possible The building official may require a
technical report to identify and develop methods of protection from hazardous
materials Section 307 1 6
7 Specify lever-type hardware for passage doors on floors accessible to the
disabled Section 2-3304, Title 24
Carlsbad 01-3127
1O/12/01
DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL
TITLE 24 DISABLED ACCESS REQUIREMENTS
8 When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected is required to
comply with all of the requirements for new buildings, per Section 1134B 2 These
requirements apply only to the area of specific alteration, repair or addition and
shall include
a) A primary entrance to the building and the primary path of travel to the
area in question, and include the following items which serve the area in
question
i) Sanitary facilities
9 Show on the plans the location of the disabled accessible parking, the path of
travel from the parking to the new area and the location of the disabled accessible
rest rooms serving the remodeled area
SANITARY FACILITIES
10 Sanitary facilities are required to be accessible, unless the enforcing agency
determines that compliance with these standards would create an unreasonable
hardship Provide a completed HARDSHIP WAIVER REQUEST FORM if
equivalent facilitation is requested to be permitted, per Section 1115B 1
11 Show that the accessible rest room is to be provided with either
a) A 60" minimum diameter clear space measured from the floor to a height of
27"
b) A clear space 56" x 63" in size
c) NOTE Doors other than the door to the accessible toilet
compartment in any position may encroach into this space by not more than
12 inches, per Section 1115B 7 1 1
12 Revise plans to show that at least one water closet fixture, located in a
compartment, shall provide the following, per Section 1115B 7 1 2
a) >28" clear space from a fixture (or >32" clear space from a wall) at one side
b) Clear space in front of the water closet shall be
i) >48" if the compartment has a end opening door
n) >60" is required for side opening doors
c) Grab bars shall not project more than 3" into the clear spaces indicated
13 Show, or note, on the plans that the accessible water closets meet the following
requirements, California Plumbing Code
a) The seat is to be >17" but < 19" in height
Carlsbad O1-3127
10/12/O1
14 Note that the doorways leading to sanitary facilities shall be identified, per Section
1115B 5, as follows
a) An equilateral triangle %" thick with edges 12" long and a vortex pointing
upward at men's rest rooms
b) A circle %" thick, 12" in diameter at women's rest rooms
c) A 12" diameter circle with a triangle superimposed on the circle and within
the 12" diameter at unisex rest rooms
d) The required symbols shall be centered on the door at a height of 60"
e) Braille signage shall also be located on the wall adjacent to the latch
outside of the doorways leading to the sanitary facilities, per Section
1117B59
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to
perform the plan review for your project If you have any questions regarding these plan
review items, please contact Chuck Mendenhall at Esgil Corporation Thank you
Carlsbad 01-3127
10/12/01
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Chuck Mendenhall
BUILDING ADDRESS 2293 Cosmos Ct
PLAN CHECK NO 01-3127
DATE 10/12/01
BUILDING OCCUPANCY SI TYPE OF CONSTRUCTION unknown
BUILDING II AREA
PORTION (Sq Ft)
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
361
cb
Rlrfn Pprmrt FPP hv OrHmanrp V
Valuation
Multiplier
City Est
By Ordinance
Reg
Mod
VALUE ($)
4,500
4,500
$61 19
Plan Check Fee by Ordinance
Type of Review
CD Repetitive Fee
Repeats
Complete Review fj Structural Only
D
Other
Hourly Hour*
Esgil Plan Review Fee
$3977
$3427
Comments
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS 3
DATE /o • /6
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER
ENGINEER
DATE
DATE /
Docs/Misforms/Plannmg Engineering Approvals
Carlsbad Fire Department 013127
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category Building Plan
Date of Report 01/08/2002 Reviewed by
Karnak Architecture
Fire Prevention
(760) 602-4660
J
Name
Address 2802 state Street Suite C
City, State Carlsbad CA 92008
Plan Checker
Job Name Oceanside Glasstile
Job Address 2293 Cosmos Court
Job# 013127
Bldg# CB013127
Ste orBldg No
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
LJ Incomplete The item .you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st ?nd 3rri
013127 FDFile#
Other Agency ID
Carlsbad Fire Department 013127
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category
Date of Report 01/08/2002
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by
Name
Address
Karnak Architecture
2802 State Street Suite C
City, State Carlsbad CA 92008
Plan Checker
Job Name Oceanside Glasstile
Job# 013127
Job Address 2293 Cosmos Court
Bldg# CB013127
Ste orBldg No
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
LJ Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st 2nH 3rd
013127 FDFile#
nthfir Agfinry in
Carlsbad Fire Department 013127
"1635 haraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report 10/10/2001
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by
Name
Address
Karnak Architecture
2802 State Street Suite C
City, State Carlsbad CA 92008
Plan Checker .
Job Name Oceanside Glasstile
Job# 013127
Job Address 2293 Cosmos Court
U
Bldg# CB013127
Ste orBldg No
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st 2nd 3rd
013127 FDFile#
Other Agency ID
Requirements Category Building Plan
Requirement Pending 05 32 Additional Requirements or Comments
The room must be a complete one-hour fire-resistive enclosure Show proper one-hour construction
for walls and ceiling
Doors must be approved one-hour rated self-closing or automatic-closing Show the rating of both
fire doors on the plans
Page 1 10/10/01
D(f)O
~XO00m
i. I
R fi § 'D m 2
O > «iis
d D> m
77 —I M
m m w
|o|1^1r~ W w
aOO
oCD
-or