Loading...
HomeMy WebLinkAbout2293 COSMOS CT; ; CB013127; Permit01-08-2002 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB013127 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2293 COSMOS CT CBAD Tl Sub Type 2130504500 Lot# $4,500 00 Construction Type Reference # OCEANSIDE TILE & GLASS ADD CONTAINMENT WALL & 2 DOORS INDUST 0 NEW Applicant RICHARDSON ROBERT 2802 STATE STREET CARLSBAD CA 92009 760-929-4000 Status ISSUED Applied 10/01/2001 Entered By JM Plan Approved 11/05/2001 Issued 01/08/2002 Inspect Area Owner AXIOM AIRPORT PARTNERS L P C/O CHRIS PISARIK 3039 CRESTA WAY 8370 01/08/02 0002 01 LAGUNA BEACH CA 92651 CGP 72-96 Total Fees $17296 Total Payments To Date $100 00 Balance Due $72 96 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $61 19 Meter Size $0 00 Add'l Reel Water Con Fee $39 77 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1 00 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2700 $2000 $2400 $000 $000 $000 $000 $17296 Inspector ^ FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition of fees dedications reservations or other exactions hereafter collectively referred to as lees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1;;: PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK EST VAL -py Plan Ck Deposit Validated Date Address (include Bldg/Suite #)Business Name (at this address) Legal Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use Proposed Use Description of Work CONTACT SQ FT #of Stones ON (if different from applicant) # of Bedrooms # of Bathrooms Name Address Contractor, i JQ Agent for Contractor Q Owner " City gerit for Owner Name 4/W 'PROPERTY OWNER Address City State/Zip Tele'phorie # Name Address City State/Zip Telephone # S CONTRACTOR COMPANY NAME ; P~' (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # :6 .WORKERS'COMPENSATION Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations 0 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued Q I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE 7 OWNER BUILDER DECLARATION s 1 hereby affirm that I am exempt from the Contractor s License Law for the following reason l~l I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) 0***l as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) [~1 I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I hj of work) I haxe icontracted (hn IB following persons to provide the work indicated (include name / address / phone number / type icvv^-v.DATE /- g~PROPERTY OWNER SIGNATURE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? fj YES "S^ NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 O YES Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES "^if NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 , CONSTRUCTION LENDING AGENCY V I -I! >*" - I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER S NAME LENDER S ADDRESS 9 APPLICANT CERTIFICATION * :" ;;: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commepeeti wdthm 180 days^f&rnjhe date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commen/3^pnoj?Q Benpa of IJKKJay^Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE tf ^ 'l/^>/y^l\L^ DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept Building Engineering Plan Check* Permit* CB013127 Project Name OCEANSIDE TILE & Planning CMWD GLASS StLite Fire-' Date 02/26/2002 Permit Type Tl Sub Type INDUST ADD CONTAINMENT WALL & 2 DOORS Address 2293 COSMOS CT Contact Person TIM Sewer Dist CA Inspected /^ _ Inspected Bv Inspected By Comments Phone 7608453003 Water Dist CA Date / / Inspected V/^y Date Inspected Date Inspected • Lot 0 Approved *^ Disapproved Approved Disapproved Approved Disapproved • .. . •< City of Carlsbad Bldg Inspection Request For 03/01/2002 Permit# CB013127 Title OCEANSIDE TILE & GLASS Description ADD CONTAINMENT WALL & 2 DOORS Inspector Assignment TP Type Tl Sub Type INDUST Job Address 2293 COSMOS CT Suite Lot 0 Location APPLICANT RICHARDSON ROBERT Owner OCEANSIDE GLASSTILE CO Remarks Phone 7608453003 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By TIM Entered By ROBIN Act Comments Associated PCRs PCR01190 PENDING Inspection History Date Description 02/26/2002 02/26/2002 02/26/2002 02/26/2002 02/12/2002 02/06/2002 02/06/2002 02/05/2002 02/04/2002 01/30/2002 19 29 39 49 17 14 17 14 14 14 Final Structural Final Plumbing Final Electrical Final Mechanical Interior Lath/Drywall Frame/Steel/Bolting/Weldmg Interior Lath/Drywall Frame/Steel/Boltmg/Weldmg Frame/Steel/Bolting/Welding Frame/Steel/Boltmg/Welding Act CO we we we AP we NR AP NR CO Insp TP TP TP TP TP TP TP TP TP TP Comments TAPE HOLES 1 HR WALL FIRE APVL WALL NPP EsGil Corporation In fartmrsflip With government for 'Buidfing Safety DATE 11/2/01 g APPLJCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 01-3127 SET II PROJECT ADDRESS 2293 Cosmos Ct PROJECT NAME Oceanside Glasstile TI ( Hazardous Materials Control Area) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) /^ Fax # Mail Telephone Fax In Person REMARKS City to verify that the exisUrfg'buildmg access and rest room facilities comply with the current disabled access standards (Applicant says building just completed) By Chuck Mendenhall Enclosures Esgil Corporation D GA D MB D EJ D PC 10/29/01 tmsmUdot EsGil Corporation In Partners/tip with government for ItuMing Safety DATE 10/12/01 OAPPLICANT JURISDICTION Carlsbad apTATTREVlEWER a FILE PLAN CHECK NO 01-3127 SET I PROJECT ADDRESS 2293 Cosmos Ct PROJECT NAME Oceanside Glasstile TI ( Storage Room) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Robert Richardson 2802 State St, Suite 'C', Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Robert Richardson Telephone # (760) 434-8400 Date contacted lo-U-°'(by &uu) Fax # C7<fc<5)-f-:b4-e4-cj7> Mail -^ Telephone ^ Fax «—• In Person REMARKS By Chuck Mendenhall Enclosures Esgil Corporation D GA n MB n EJ n PC 10/2/01 tmsmUdot 9320 Chesapeake Drive, Suite 208 +• San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad O1-3127 10/12/01 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 01-3127 JURISDICTION Carlsbad OCCUPANCY SI USE storage TYPE OF CONSTRUCTION unknown ACTUAL AREA 361 ALLOWABLE FLOOR AREA SPRINKLERS'? unknown REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED 10/12/01 STORIES HEIGHT OCCUPANT LOAD 1 DATE PLANS RECEIVED BY ESGIL CORPORATION 10/2/01 PLAN REVIEWER Chuck Mendenhall FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1994 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e . plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans LIST NO 40 TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC)tiforw dot Carlsbad O1-3127 10/12/O1 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, Carlsbad, CA 92009, (760) 602-2721 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 3 Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC 4 Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E 5 What is the purpose of the use of fire rated doors'? Why aren't the new walls fire rated? 6 A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible The building official may require a technical report to identify and develop methods of protection from hazardous materials Section 307 1 6 7 Specify lever-type hardware for passage doors on floors accessible to the disabled Section 2-3304, Title 24 Carlsbad 01-3127 1O/12/01 DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL TITLE 24 DISABLED ACCESS REQUIREMENTS 8 When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply only to the area of specific alteration, repair or addition and shall include a) A primary entrance to the building and the primary path of travel to the area in question, and include the following items which serve the area in question i) Sanitary facilities 9 Show on the plans the location of the disabled accessible parking, the path of travel from the parking to the new area and the location of the disabled accessible rest rooms serving the remodeled area SANITARY FACILITIES 10 Sanitary facilities are required to be accessible, unless the enforcing agency determines that compliance with these standards would create an unreasonable hardship Provide a completed HARDSHIP WAIVER REQUEST FORM if equivalent facilitation is requested to be permitted, per Section 1115B 1 11 Show that the accessible rest room is to be provided with either a) A 60" minimum diameter clear space measured from the floor to a height of 27" b) A clear space 56" x 63" in size c) NOTE Doors other than the door to the accessible toilet compartment in any position may encroach into this space by not more than 12 inches, per Section 1115B 7 1 1 12 Revise plans to show that at least one water closet fixture, located in a compartment, shall provide the following, per Section 1115B 7 1 2 a) >28" clear space from a fixture (or >32" clear space from a wall) at one side b) Clear space in front of the water closet shall be i) >48" if the compartment has a end opening door n) >60" is required for side opening doors c) Grab bars shall not project more than 3" into the clear spaces indicated 13 Show, or note, on the plans that the accessible water closets meet the following requirements, California Plumbing Code a) The seat is to be >17" but < 19" in height Carlsbad O1-3127 10/12/O1 14 Note that the doorways leading to sanitary facilities shall be identified, per Section 1115B 5, as follows a) An equilateral triangle %" thick with edges 12" long and a vortex pointing upward at men's rest rooms b) A circle %" thick, 12" in diameter at women's rest rooms c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms d) The required symbols shall be centered on the door at a height of 60" e) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per Section 1117B59 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you Carlsbad 01-3127 10/12/01 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Chuck Mendenhall BUILDING ADDRESS 2293 Cosmos Ct PLAN CHECK NO 01-3127 DATE 10/12/01 BUILDING OCCUPANCY SI TYPE OF CONSTRUCTION unknown BUILDING II AREA PORTION (Sq Ft) Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 361 cb Rlrfn Pprmrt FPP hv OrHmanrp V Valuation Multiplier City Est By Ordinance Reg Mod VALUE ($) 4,500 4,500 $61 19 Plan Check Fee by Ordinance Type of Review CD Repetitive Fee Repeats Complete Review fj Structural Only D Other Hourly Hour* Esgil Plan Review Fee $3977 $3427 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS 3 DATE /o • /6 RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE / Docs/Misforms/Plannmg Engineering Approvals Carlsbad Fire Department 013127 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category Building Plan Date of Report 01/08/2002 Reviewed by Karnak Architecture Fire Prevention (760) 602-4660 J Name Address 2802 state Street Suite C City, State Carlsbad CA 92008 Plan Checker Job Name Oceanside Glasstile Job Address 2293 Cosmos Court Job# 013127 Bldg# CB013127 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards LJ Incomplete The item .you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st ?nd 3rri 013127 FDFile# Other Agency ID Carlsbad Fire Department 013127 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category Date of Report 01/08/2002 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Karnak Architecture 2802 State Street Suite C City, State Carlsbad CA 92008 Plan Checker Job Name Oceanside Glasstile Job# 013127 Job Address 2293 Cosmos Court Bldg# CB013127 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards LJ Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2nH 3rd 013127 FDFile# nthfir Agfinry in Carlsbad Fire Department 013127 "1635 haraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 10/10/2001 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Karnak Architecture 2802 State Street Suite C City, State Carlsbad CA 92008 Plan Checker . Job Name Oceanside Glasstile Job# 013127 Job Address 2293 Cosmos Court U Bldg# CB013127 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2nd 3rd 013127 FDFile# Other Agency ID Requirements Category Building Plan Requirement Pending 05 32 Additional Requirements or Comments The room must be a complete one-hour fire-resistive enclosure Show proper one-hour construction for walls and ceiling Doors must be approved one-hour rated self-closing or automatic-closing Show the rating of both fire doors on the plans Page 1 10/10/01 D(f)O ~XO00m i. I R fi § 'D m 2 O > «iis d D> m 77 —I M m m w |o|1^1r~ W w aOO oCD -or