Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2298 BRYANT DR; ; CB100289; Permit
03-15-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No: CB100289 Building Inspection Request Line (760) 602-2725 Job Address: 2298 BRYANT DR CBAD Permit Type: ELEC Status: ISSUED Parcel No: 2121014400 Lot#: 0 Applied: 02/18/2010 Entered By: RMA Reference*: Plan Approved: 03/15/2010 PC#: Issued: 03/15/2010 Project Title: ADELMAN RES-NEW PHOTOVOLTAIC Inspect Area: & SOLAR HOT WATER SYSTEMS-ROOF MOUNTED ON GARAGE Applicant: NORTH COUNTY SOLAR 1039SOLANADR 92028 760 695-8802 Owner: ADELMAN PHYLLIS J 473 CAREFREE WAY FRIDAY HARBOR WA 98250 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees 0 0 0 0 $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $175.00 $0.00 TOTAL PERMIT FEES $185.00 Total Fees:$185.00 Total Payments To Date:$185.00 Balance Due:$0.00 v- > Inspector:m FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www.carisbadca.gov Plan Check No. Est. Value Plan Ck. Deposit Date JOB ADDRESS 2298 Bryant Drive "CT/PROJECT #TOTST # OF UNITS I # BEDROOMS 212 101 44 00 # BATHROOMS TENANT BUSINESS NAME CONSTR.TYPE IOCC.GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Installation of solar grid tie photovoltaic system and solar thermal hot water system fl EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YESQf NCQ AIR CONDITIONING FIRE SPRINKLERS YES | |NO| | CONTACT NAME (If Different fom Applicant)APPLICANT NAME Michael Cornelius ADDRESS ADDRESS 1039 La solana Dr. CITY STATE ZIP CITY Fallbrook STATE Ca.ZIP 92028 PHONE FAX PHONE 7606958802 FAX EMAIL EMAIL northcountysolar@roadrunner.com PROPERTY OWNER NAME Adelman CONTRACTOR BUS. NAME North County Solar ADDRESS 2298 Bryant Drive ADDRESS 1039 La soiana Dr. CITY Carlsbad STATE Ca. ZIP 92008 CITY Fallbrook STATE Ca. ZIP 92028 PHONE FAX PHONE 7606958802 FAX EMAIL EMAIL northcountysotar@roadrunner.com ARCH/DESIGNER NAME & ADDRESS STATE LIC.# 864713 CLASS C-46 civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of (fie following declarations: r1 1 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. [ _ 1 1 have and will maintain workers' compensation, as required bv Section 3700 of the Labor Code, for the performance of the work lor which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co _ , _ , _ Policy No. ___ _ , __ Expiration Date _ This section need not be completed if the permit is for one hundred dollars ($1 00) or less. [/I Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&1 00,000), in addition to the cost of compensation, damages as provided for injection 3J06pf the Labor code, interest and attorney's fees. JS*> CONTRACTOR SIGNATURE n 3J06pf the ~^1AGENT DATE O W NER-BUILDER DECLARATI ON / hereby affirm that I am exempt from Contractor's License Law for the following reason: [~ | l, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's — License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). 1 am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. l~~lYes I [NO 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ["""I /^PROPERTY OWNER SIGNATURE []AGENT DATE COMPLETE THIS SECTION FOR N O N - R E S I O E N T I A L BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I I Yes L—JNo __ Is the applicant or future building occupant required to obtain a permit from the air pollution control district or ainjuality management district? I TVes I I No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I Ives FlNo ICY MAY NOT EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address CERTIFICATION I certify thatl have read the application and statethat the above information is correct and that the Mbnration on the plans is accurateJa^tocomp^ I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING Of THIS PERMIT. OSHA: An OSHA permit is required for excavations over SO1 deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within ^APPLICANTS SIGNATURE DATE City of Carlsbad Bldg Inspection Request For: 03/31/2010 Permit* CB100289 Title: ADELMAN RES-NEW PHOTOVOLTAIC Inspector Assignment: Description: & SOLAR HOT WATER SYSTEMS-ROOF MOUNTED ON GARAGE Sub Type:Type: ELEC Job Address: 2298 BRYANT DR Suite: Lot: 0 Location: APPLICANT NORTH COUNTY SOLAR Owner: ADELMAN PHYLLIS J Remarks: GATE CODE #2846 PHOTO ONLY Phone: 7606958803 Inspector: Total Time: Act Comments Ft Requested By: MICHAEL Entered By: JANEAN CD Description 39 Final Electrical Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments EsGil Corporation In Partners Kip with government for (Building Safety DATE: 03/12/2010 g APPLICANT C? JURI§) JURISDICTION: City of Carlsbad aTOw REVIEWER a FILE PLAN CHECK NO.: 10-0289 SET: III PROJECT ADDRESS: 2298 Bryant Dr. PROJECT NAME: Adelman Roof Mounted 4 kW PV System & Passive Hot water system XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: North County Solar 1039 La Solana Dr. Fallbrook, CA 92028 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Michael Cornelius Telephone #: 760-695-8802 Date contacted: (by: ) Fax #: 760-695-8803 Mail Telephone Fax In Person northcountvsolar@roadrunner.conn REMARKS: Hand Carry By: Aaron Goodman Enclosures: EsGil Corporationn GA n EJ n PC 03/12/2010 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In Partnership with government for (BuiUing Safety DATE: 03/11/2010 JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 10-0289 SET: II PROJECT ADDRESS: 2298 Bryant Dr. PROJECT NAME: Adelman Roof Mounted 4 kW PV System & Passive Hot water system The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: North County Solar 1039 LaSolana Dr. Fallbrook, CA 92028 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Michael Cornelius Telephone #: 760-695-8802 Date contacted: 3/^A* (by</^ Fax #: 760-695-8803 Mail ^/Telephone Fax In Person northcountvsolar@roadrunner.com REMARKS: By: Aaron Goodman Enclosures: EsGil Corporation D GA D EJ D PC 03/04/2010 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 10-0289 03/11/2010 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. 1. Please make all corrections and submit two new complete sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (858) 560-1468. 2. REMINDER: All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 10. Unless otherwise specified, not less than thirty (30) inches in depth, width, and height of working space and platform shall be provided to service mechanical appliances. No PV modules shall encroach in this space. Exception: If the equipment listing is provided that shows that the required clearances around and above the units may be less than required above. UMC 305 and NEC 110.26. NO RESPONSE. THE REVISED SITE PLAN DOESN'T SHOW THE SOLAR WATER SYSTEM COLLECTOR LOCATION. PLEASE ADD SHOWING THAT WORKING SPACE OF THE ARRAY IS MAINTAINED. ROOF MOUNTED INSTALLATIONS 11. Provide a section of the garage showing the roof framing and call out the pitch of the roof on the plans. NO RESPONSE. PASSIVE SOLAR THERMAL HOT WATER SYSTEM 13. The plumbing schematic shows the E Tech RO60 Hot Water Cube connected to this system, however, it is not shown on the site plan. Please show where this equipment will be installed. NO RESPONSE. 14. A condensate drain run to an approved location is required for the E Tech RO60 Hot Water Cube. Please call out a condensate drain on the plans. NO RESPONSE. IS IT RUN TO THE OUTSIDE? WHERE DOES IT TERMINATE? TERMINATION AT A SIDEWALK OR PATIO IS NOT PERMITED. IT MUST TERMINATE IN A LANDSCAPED AREA OR DRAIN. PLEASE SHOW ON THE PLANS. 15. Show the T and P relief valve at the water heater and the discharge pipe size and routing to the exterior. CPC Section 608.3. NO RESPONSE. IS IT RUN TO THE OUTSIDE? WHERE DOES IT TERMINATE? TERMINATION AT A SIDEWALK OR PATIO IS NOT PERMITED. IT MUST TERMINATE IN A LANDSCAPED AREA OR DRAIN. PLEASE SHOW ON THE PLANS. City of Carlsbad 10-0289 03/11/2010 END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Aaron Goodman at Esgil Corporation. Thank you EsGil Corporation In (Partnership •with government for (Buiftfing Safety DATE: 02/26/2010 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 10-0289 SET: I PROJECT ADDRESS: 2298 Bryant Dr. PROJECT NAME: Adelman Roof Mounted 4 kW PV System & Passive Hot water system The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 2<] The applicant's copy of the check list has been sent to: North County Solar 1039 LaSolanaDr. Fallbrook, CA 92028 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Michael Cornelius Telephone #: 760-695-8802 Date contacted :3 1) //<? (b^fe Fax #: 760-695-8803 Mail\X^e'ePhone Fax JXm Person northcountvsolar@roadrunner.com REMARKS: By: Aaron Goodman Enclosures: EsGil Corporation D GA D EJ D PC 02/19/2010 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 10-0289 02/26/2O10 GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2298 Bryant Dr. DATE PLAN RECEIVED BY ESGIL CORPORATION: 02/19/2010 REVIEWED BY: Aaron Goodman PLAN CHECK NO.: 10-0289 DATE REVIEW COMPLETED: 02/26/2010 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Mechanical Code, National Electrical Code, International Fire Code, NFPA 13, 13R, 13D, 17, 17A, 72, and state laws for disabled access. This plan review is based on regulations enforced by the Building/Fire Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Yes a No City of Carlsbad 10-0289 02/26/2010 1. Please make all corrections and submit two new complete sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (858)560-1468. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2007 California Building Code, which adopts the 2006 IBC, 2006 UMC. 2006 UPC and the 2005 NEC. 4. Add a "Scope of Work" on the title sheet or coversheet of the plans and show in the plans all structures and equipment included with this project. Any portion of the project shown that is not that is not part of this project should be clearly identified as "not included." Sec. A106.1.1. 5. The dwelling appears to be in between the garage and service. Please call out on the plans if this is a mobile or manufactured home. If this is a mobile home park, please call this out on the plans. 6. Call out on the plans the number and size of all conductors from each output circuit or series connected panel, inverter input circuit and inverter output circuit to the main panel. Describe the wiring methods to be used. Be sure to show compliance with NEC Article 690.31 for approved cable types. If you intend to use non-metallic sheathed cable, call out the rating of the cable on the plans and show how the cable will be run from the inverter to the service. 7. Provide a grounding electrode system sized per Table 250.66 at the structure on which the PV System and/or inverter is installed per 250.50. See 690.47 (A). Show the location and size of the system on the single line plan. 8. Provide a plaque or label with the following information at the inverter or disconnecting means for the PV power source circuits: 690.53 1) Operating current 2) Operating voltage 3) Maximum system voltage 4) Short-circuit current 9. The output of a Sunny Boy 4000 exceeds 20 amps. A single 20 amp breaker is shown at the service, however, note 6 talks about "2 30A disconnects and 1 200A service." The maximum size that the backfed breaker can be in a 200A service is 40A. Please clarify the size of the backfed breaker in the service. Show/call out the ampere rating of overcurrent devices in circuits supplying power to the main panel busbar. The sum of the ampere ratings of the overcurrent devices shall not exceed 120 percent of the rating of the busbar. City of Carlsbad 10-0289 02/26/201O Include all existing main service disconnect sizing to verify compliance with NEC 690.64. 10. Unless otherwise specified, not less than thirty (30) inches in depth, width, and height of working space and platform shall be provided to service mechanical appliances. No PV modules shall encroach in this space. Exception: If the equipment listing is provided that shows that the required clearances around and above the units may be less than required above. UMC 305 and NEC 110.26. • ROOF MOUNTED INSTALLATIONS 11. Provide a section of the garage showing the roof framing and call out the pitch of the roof on the plans. 12. Please add the following note to the plans: "Roof coverings shall be designed, installed and maintained in accordance with this code and the approved manufacturer's instructions such that the roof covering shall serve to protect the building or structure. CBC 1503." PASSIVE SOLAR THERMAL HOT WATER SYSTEM 13. The plumbing schematic shows the E Tech RO60 Hot Water Cube connected to this system, however, it is not shown on the site plan. Please show where this equipment will be installed. 14. A condensate drain run to an approved location is required for the E Tech RO60 Hot Water Cube. Please call out a condensate drain on the plans. 15. Show the T and P relief valve at the water heater and the discharge pipe size and routing to the exterior. CPC Section 608.3. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Aaron Goodman at Esgil Corporation. City of Carlsbad 10-0289 O2/26/2010 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 1O-O289 PREPARED BY: Aaron Goodman DATE: 02/26/2010 BUILDING ADDRESS: 2298 Bryant Dr. Set I BUILDING OCCUPANCY: R-3 / U TYPE OF CONSTRUCTION: V-B BUILDING II AREA PORTION ( Sq. Ft.) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance $215.00 Type of Review: [H Repetitive FeeRepeats D Complete Review D Other j—i Hourly EsGil Fee $86.00 Structural Only Mrs. $172.00 Based on hourly rate Comments: Roof Mounted PV System and Passive HWT System Sheet 1 of 1 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 10-0289 DATE 2/19/10 ADDRESS 2298 Bryant Drive RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER solar panels PLANNER Chris Sexton ENGINEER DATE 2/19/10 DATE H:\ADMIN\MNTER/PLANNING/ENGINBING APPROVALS «»"*iV Serrated base grips the roof deck to prevent the base from moving while installing the lag bolt USED FOR MOUNTING: Photovoltaic Solar Panels Solar Thermal Panels Communication Equipment Virtually anything needing structural attachment to a roof! professional SOLAR products'^ (800) 84-SOLAR (805) 383-0802-fax 4630 Calle Quetzal Camarillo, CA 93012 View more info on our website at: www.RoofTrac.com/ fastjack.htm If"1 g f m ""\ tested toFastJack ••-?• Flashable Roof Stanchion •Patent #6,360,491 The patented design of the FastJack® can be easily expressed as the most innovative, efficient and cost-effective tool of it's kind! Between the precision CNC machined base and stanchion along with strict engineering and material standards, the FastJack® has been laboratory tested to provide 1,200 pounds of strength using only a single lag bolt (included)! Four Sizes Available! FastJack9 F/-300 For Oatey® style flashings I FastJack* 3" High Part* FJ-300 J»,_ For low profile installations using Oatey® flashings (for composi- jtion shingle roof-tops) f FastJack* 4-1/2" High Part* FJ-MO FFor installations using standard flashings (for composition 6> flat F rooftops) FastJack*1 6" High Part* FJ-600 For standard flashings (for flat tile rooftops) FastJack* 7-VS" High Part* FJ-750 For standard flashings (sized for S-curve tile roofs and/or double flashed installations) FastJack® FJ-450 For standard height flashings The Fast Jack8 design is covered under Pat. #6,360,491 Commercial FasUack® also available (rated at 4,250 Ibs.) Benefits of the Fast Jack® • Removeable post makes installation on existing roofs/retrofit quick and easy (refer to the illustration to the right) • Patented design locates the lag bolt directly under the stanchion providing superior strength values • Fast & easy to install - saves time and labor costs • Precision machined from extruded alu- minum, there are no welds to corrode or break • Significantly lighter than steel for installer convenience and reduced shipping costs. • Integrated drill guide insures perfect pilot holes every time - minimizes the possibility of splitting roof rafters • Base design allows virtually any roof flashing to install flat on the roof deck Email us for more information prosolar@prosolar. com Easy installation of flashings on existing roof-tops Standard & Oatey® Flashings slip over the base and under the delicate shingle 3/8" x 3/4" SS Hex Bolt 3/8" SS Flat Washer The post can be installed through the top of the flashing WxS" SSUsBott JackBM* ROOF INSTALLATION FOR THE FASTJACK® FLASHABLE SUPPORTS DRILL PILOT HOLE /- 3/8" BOLT & WASHER ? / /-- 5/16" LAG BOLT & WASHER / - FLASHING INSTALLED SUPPORT INSTALLED FASTJACK FASTJACK INSTALLED ROOF SHINGLE FASTJACK STANCHION INSTALLATION Installation of the FASTJACK® support rails to the attachment feet. The illustration above shows how the FastJack™ flashable mount is installed on a new roof, (see the following page for more detailed installation instructions). The same spans apply to the FASTJACK® mount as with the TILE TRAC®, attachment feet. All attachments to the roof should be made at 48" rafter centers, and all rafters must be located and securely bolted into. There are four heights of FASTJACK® mounts and they range from 3", which is generally used for the Oatey® style neoprene (low profile) flashing, to 7-1/2". The 4-1/2" is recommended for mounting to the composition shingle roof using a standard metal roof flashing. The 6" and 7-1/2" sizes are for flat tile roofs and curve tile using double flashings. One feature of the FASTJACK® is that the roofer can remove the posts for easy installation of the roof paper and later install them. After the FASTJACK® mounts are installed, the support rails can be marked and installed in the same manner as illustrated on page 6 of the manual. Fig #1: FASTJACK® base is installed over the roof rafter and sheathing. Fig #2: Threaded post is screwed into the base and the f lashing is installed over it. Fig # 3: Installed FASTJACK® ready for the roof covering. Caution: Always use care when walking around protruding stanchions. PageS COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products (PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029. FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491. INSTALLATION OF THE FASTJACK® FLASHABLE ROOF STANCHION 3/8" BOLT FASTJACK® flashable mount system includes a machined aluminum base with integrated drill guide, 1" aluminum threaded post and stainless steel hardware. The FJ Series patented (pat #6,360,491) design is engineered to provide structural attachment of modules when conventional roof flashings are required. FJ mounts are available in two sizes; the 4-1/4" FJ-425 (for conventional metal flashings) and the 3" FJ-300 for Oatey® style (low profile) neoprene flashings. The FJ design allows all flashings to install flat on the roof decking. FJ's superior strength while using only one single lag bolt (included) results from having the bolt installed directly under the support post. The system has been laboratory tested to 1,200 pounds and along with it's integrated drill guide insures perfect connections every time. 3/8" WASHER THREADED POST 5/16" LAG BOLT 5/16" WASHER DRILL GUIDE MACHINED BASE 3/16" DRILL GUIDE ' 5/16" LAG BOLT HOLE ROOF RAFTER 1" THREADED BASE R1 FASTJACK™ INSTALLED PARTS DIAGRAM REQUIRED TOOLS: 3/16" DRILL BIT AND POWER DRILL 1/2" SOCKET 1" PIPE PLIERS FJ-300 SERIES FJ-425 SERIES DRILLING THE PILOT HOLE Place the mount base of the over the location of the rafter. Align the 3/16" (drill guide) over the rafter center. While holding the base—insert the bit through the guide and drill down approx 1" into the roof. DRILL BOLTING INTO THE RAFTER Place the 5/16" lag bolt thru the washer and AF base. Insert the lag bolt into the pilot hole made in the roof. Drive the lag bolt into the rafter using a 1/2" socket and impact wrench. 1/2" INSTALLING THE POST SUPPORT Screw the threaded post into the base and tighten with a pipe pliers. Install the flashing over the post and attach the module support using the 3/8" bolt and washer (included). ROOF FLASHING TIGHTEN POST SUPPORT INTO BASE Page 9 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products (PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029. FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491. INSTALLATION OF TILE TRAC® STEP1 STEP 2 STEP 1: MARK A REFERENCE LINE ACROSS THE TILES IN THE VACINITY OF THE ROOF RAFTER. REMOVE THE ROOF TILE BY PUSHING AND PULLING ON THE TILE: IT IS HELD IN PLACE BY A SMALL NAIL. LIFT WITH A FLAT NAIL BAR IF NECESSARY. STEPS STEP 2: LOCATE THE CENTER OF THE RAFTER BY TAPPING WITH A HAMMER OR USING AN ELECTRONIC STUD SENSOR. AFTER LOCATING THE CENTER OF THE RAFTER DRILL A 3/16" PILOT HOLE IN LINE WITH THE CHALK LINE. STEP 4 STEP 3: INSTALL THE LOWER TRACK ASSEMBLY USING A 5/16" LAG BOLT AND SPECIAL WASHER. PLACE SEALANT AROUND BOLT AND LOWER TRACK, BE SURE TO SEAL THE NAIL HOLE FROM THE TILE YOU REMOVED. STEPS STEP 4: AFTER INSTALLING THE LOWER TRACK, SLIDE THE UPPER MOVABLE CARRIAGE ASSEMBLY INTO POSITION AT THE HIGH POINT OF THE TILE. STEP 6 STEP 5: REPLACE THE TILE AND DRILL A 3/8" HOLE USING A MASONRY DRILL, INTERSECTING THE REFERENCE LINE AND THE HIGH POINT OF THE TILE. STEP 7 BIND TWO 3/8" NUTS TOGETHE STEP 6: INSERT THE THREADED SHAFT THROUGH THE HOLE IN THE ROOF TILE, LOCATING THE UPPER TILE TRAC® CARRIAGE. IF NECESSARY, PICK UP THE ROOF TILE TO ASSIST IN STARTING THE THREADED SHAFT. INSERT AND LOCK TWO 3/8" NUTS ON THE THREADED SHAFT AND TIGHTEN DOWN USING A 9/16" WRENCH. STEPS REFER TO PAGE SIX FOR INSTALLATION OF THE SUPPORT RAIL. STEP 7: INSERT AND LOCK TWO 3/8" NUTS ON THE THREADED SHAFT AND TIGHTEN DOWN USING A 9/16" WRENCH. STEP 8: APPLY SEALANT AROUND THE THREADED SHAFT COMPRESSING THE SEALANT WITH THE ENCLOSED 3/8" WASHER. Page 10 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products (PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029. FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #8,360,491. • ,: ,'•• -,- . DO | -20' «- ' J' 6>/> 5 <r/Wu<' ti ^OUW ^.^ <,oM-1-'. F/UI >' / pUi: SolarRoofs "Skyline" 10-01 and 20-01 Solar Collectors: These rug- ged, powerful 10 and 20 Square foot collectors weigh only 19 and 38 pounds. They are easy to carry by one person and are much safer to get on the roof to install. They are available in architectural colors and have an attractive appearance on the roof. No soldering is required to install the collector (s). Architecturally Attractive Collector Designed by an Award Winning Inventor. Long, and low, this collector is the most attractive of all. It is also available in special easy to ship (Patented) UPS shippable "Split Kit" and special "24' long SKYLINE" models. Unbreakable, double walled Polycarbonate glazing is lightweight, has high insulation value and excellent UV protection with 10 year full warranty 150MPH—FSEC wind tested easy mount system. Easy install mounting bracket is covered by trim for attractive appear- No Solder compression unions for easy connections. Patented "Floating Fin" prevents damage by allowing the tube to disappear into the collector during shipment. High Performance All Copper Solar Absorber Plate with Premium "Black Crystal" coating. Rigid Foam Insulation, Aluminum foil faced, glass reinforced, Polyisocyanurate, 1" on the bottom and 1/2" on the sides provides quality heat retention. COLLECTOR SPECIFICATIONS: Trim & Frame Materials: Absorber Material: Glazing: Dimension / Weight: Recommended Flow Rate: Maximum Working Pressure: Heat Transfer Fluid: Standard Components: Color: Finished 27 mil Aluminum Trim and Frame = Total 54 mil (1.37 mm) "Black Crystal" or Black Chrome coated absorber with all copper 1/2" od tube Twinwall Polycarbonate UV Treated .236" (6.0 mm) 72" / 144.1"x 20"x 3" 19 / 38 Ib = 1.9 Ib. s/f (3.67 m x 0.51 m x 0.076 m 17.24 Kg) 18.4 net s/f (1.71 m2) .20 to .6 GPM 150 PS1 (10.21 atm) Maximum Stagnation Temp: 250 °F (121.11 °C). Potable water or Propylene glycol - Fluid Capacity: 10-01 = .15 gal. / 20-01 = .3 gal. Mounting Ell brackets with tech screws and 2 1 1/4" washers. Standard: Musket Brown or Dove Gray. Optional trim colors are available. SolarRoofs 20-01 SRCC OG 100 Collector Rating: COLLECTOR THERMAL PERFORMANCE RATING SOLAR COLLECTOR CERTIFICATION AND RATING SRCC OG-100 CERTIFIED SOLA^ CftLLECTUR SUVUER ACR Solar Inurnaiiocnl 5840GibtxmsDr. Canrnchael.CA9*>08 MODbL: Flirt* F>n*a]l 2001 CERTIFICATION t: 100-200I-002A Thousands of Btu Per Panel Per Da; CATEGORY ( Ti-Ta) A (-9 °F) B (9°F) C (36 °F) D (90 °F) E (144 °F) CLEAR DAY 2000Btu/ft2-d 23 20 17 10 6 MILDLY CLOUDY 1500Btu/nz-d 17 15 11 6 2 CLOUDY DAY 1000Btu/ft2d 12 9 6 1 Web: www.SoIarRoofs.com Email: richsolar@aol.coin Phone: (916) 481-7200 Fax: (916) 481-7203 Address: 5840 Gibbons Drive Suite G, Carmichael CA 95608 aters, Boilers and Pool Heaters Standard Features Suit Saver Solar Water Heaters Exceeds ASHRAE Energy Standards 1 Foam Insulation - Improved formulation provides uniform tank coverage with a thick blanket of insulating foam. This non-CFC polyurethane closed cell foam minimizes standby heat loss and maximizes heat retention. Glass-Lined Tank - Fused to the tank at 1600°F, the durable glass lining is triple-tested, assuring lasting protection against rust and corrosion while providing clean, clear hot water. Magnesium Tank Saver - A large diameter anode rod provides lasting protection from the effects of electrolytic corrosion. 1 Dielectric Nipples - Protect the tank from corrosive action between dissimilar metals, and reduce installed cost. Thermal Isolation - Unique design prevents heat loss through the bottom of the tank. Side Relief Valve Tapping - This provides quicker, labor-saving installation. Pre-Wired Tank Sensor Lead 1 Heating Element - 4500 watt immersion type heating element for heating system back-up. • Certified at 300 psi test pressure - for 150 psi working pressure all models . 1 Brass Drain Valve 1 Warranty - Six or Ten year limited tank warranty. Six year warranty on parts. (See warranty for details) Sun Saver Solar Dimensions and Specification A. Wires from Sensor Mounting Stud B. Thermostat C. Heating Element 0. Collector Return Tube E. System Inlet Tube F. T Non-CFC Foam Insulation G. Pump Suction Tube H. Hot Outlet/Anode Rod 1. Sensor Mounting Stud J. Thermal Feet K. Glass Uned Tank L Brass Drain Valve M.T&P Valve Opening N. Alternate Collector Return Opening 0. Alternate Collector Supply Opening TOP VIEW #1 - 3/4" Pump Suction #2 - 314" Cold Inlet #3 - 3/4" Collector Return #4 - 3/4" Hot Outlet L. B .J T D o Model Gallon Number Capacity FTA066K 65 59"22"52-1/2" Alt. Coll. Return Alt. Coll. Supply Shipping Weight 165 FTA082K*80 59"24"52-1/2"38"8"210 FTA120K* 119 62-3/4" 28" 56" 38-1/4" 8" Notes: "Models feature alternate collector supply and return connections. Change "F" to "T" for 10 year warranty. Voltage and wattage; 240V10-4500W. 310 Far Ease In Ordering By Model Number FT A 082 K This heater is a Solar water heater with a 6 year warranty. It has an 82 gallon tank capacity and one 240V 10, 4500 watt element.. All models available with either a Six Year Limited Warranty or a Ten Year Limited Warranty Against Tank Failure. All parts are warranted for six years. Three year limited warranty on all models when installed in a commercial application. ^Lodiinvar * ' niah VfffefMWv W.t»r ¥¥mtl>rs ItAjlortt anil Pnnl n»t»nHigh Efficiency Water Healers, Boilers and Pool Healers Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 www.Lochinvar.corn SO-05 (Revised SO-05 11/06) 1/08-Printed in U.S.A. •TECJHJ Energy Savings Solutions Product Data Sheet R060 Residential High Efficiency Heat Pump Water Heater Description: The R060 "Hot Water Cube" is an add-on heat pump water heater, designed to be mounted on a wall or shelf near a standard electric hot water heater. It is a medium capacity machine intended for the typical 1-3 person home, or where hot water demand is lower. The R060 uses 40-70% less electricity than standard electric hot water heaters and provides cool dehumidified air as it operates. It uses an environmentally friendly refrigerant. When installed to replace a fossil fuel heater it eliminates harmful fossil fuel emissions. The R060 is typically installed in basements, garages, workshops or large utility closets. Features • Selector switch for three modes of operation - heat pump, off (vacation mode), or electric resistance heater. • Automatic conversion to electric heating (using storage tank elements) in a fault condition. • Heat pump can be removed for servicing without a long interruption of the hot water supply. (The water heating is then performed by the resistive elements.) • High refrigerant pressure protection. Unit will turn off and switch to electric resistance heating in a high pressure condition. • Low ambient temperature protection. Unit will turn off and switch to electric resistance heating to prevent evaporator freezing. Options • Connection Kit: All of the accessories needed to install the R060 to the electric hot water heater. Performance Data (Based ontherXXefltiency testing amMrtcondtw C.O.P.: 3.3 (Avg. when going from a 58T tank to a 125^ tank.) Heating Output: 5,900 Btu/hr (nominal) Cooling Capacity: 4, 100 Btu/hr Dehumidification Capacity: 0.75 Pints/hr Components P . Va ton (nominal) rotary hermetic with externalp ' overload protection. r , . Double wall - suitable for potable water, with on enser. COpper water and steel refrigerant passages. •of 67.5f,50%mand58Fertaringwalertempefaluns.) RerovPrv Rate- 9'4 9ph at 1 35<F tank temp'Recovery Rate. 12 6 gph gt 1 ^ tgnk temp Water flow rate (internal): 1 .7 gpm Sound level: Less than 60 db(A) at 5 feet Maximum tank temperature: ISSf Fan: 240 cfm Pump: Wet rotor, 1/40 hp (nominal) Refrigerant: R-134a Filter: Washable foam Ambient Operating Range Minimum Operating Temp: 45^ +/- 2T ( Areas with high humidity may cut out at higher temperatures.) Maximum Operating Temp ^Q5T AERS, Inc. • 6670-A Corners Industrial Court • Norcross, Ga. 30062 • Ph: 770.734.9696 • Fax: 770.453.9323 • sales@aers.com •www.aers.com Specifications are subject to change without notice.R060 Data Sheet Rev. F 5-08 Electrical Data Power: 230/208 VAC, 1 ph, 60 Hz. The unit is wired to the storage tank, a separate circuit is not required FL Current: 7 Amps Weight & Dimensions Weight (empty): 80 Ibs. Shipping weight: 95 Ibs. Dimensions: 21"h x 16"w x 14"d Shipping Dimensions: 26"h x 30"w x 19"d Installation Requirements Water Heater: The R060 works in conjunction with a standard electric water heater and uses the water heater thermostats and storage tank. It also uses the upper heating element for backup operation. The requirements of the electric water heater are: • Minimum 40 gallon storage tank, larger is generally better. • Maximum tank element size of 6000 Watts. • Operate on 230/208 VAC, 1 ph, 60 Hz power. • Hot and cold water connections should be %" pipe thread. Clearances: Minimum clearances for proper air flow are: • 24" in front of fan, 24" in front of evaporator. Allow adequate clearance on top for servicing. Location: The R060 must be sheltered from the weather. A minimum of 800 cubic feet of space -1000 is recommended - smaller spaces will require vents or ducting. A condensate drain or pump is required. Operating Curves & Dimension Drawing COP vs. Final Tank Temperature TOP VIEW 115 120 125 Final Tank Temperature (8F) Recovery Rate (gph) vs. Final Tank Temperature FRONT VIEW EVAPORATOR 115 120 125 Final Tank Temperature (*F) AERS, Inc. • 6670-A Comers Industrial Court • Norcross, Ga. 30062 • Ph: 770.734.9696 • Fax: 770.453.9323 • sales@aers.com •www.aers.com Specifications are subject to change without notice.R060 Data Sheet Rev. F 5-08 Composition Shingle roof Skyline 2001 Collectors 12lLx20"Wx3"D 38lbsea. 3 Total .l.fci.l.l.i.l.l.ki.l.l.l.t.ti.l.l.l.H.H.I.l.t.l.l.tfcMl.tl.Hi.l.H.l.l.l.^.l.kl.l.l.I.l.i.i.l.i.t.l.l.fc^.i.^i.l.l.l.i.i.ki.l.t.l.i. . it. . . . 7J. . i-.-i-i-yS... V.-...^ -. ...... mr.. Thermal Array Mounting^ 3 Panels. Side view Thermal Array Mounting 3 Solaroofs 2001 Modules Stand-offs, typically 4 per loaded rafter- 14.72 Ibs. load per standoff Panel Weight: 38 Ibs ea. # of panels 3 Total Panel: 114 Ibs Rack Weight: 18.5 Ibs Total Weight: 132.5 Ibs # of Stand-offs: 9 Loading: 14.72 Ibs per Skyline 2001 Collectors mounted to 1" x 2" aluminum square tube. 3 Total Standard wood truss construction, 2x6 rafters 24" O.C. to form gabled roof(s), Roof sheathing with 1/2" cd-x ply (32/16) W/8d @ 6" p / c supported panel edges, 12" o / c at field. Upper surface of plywood faced with felt paper. Finished roof surface is composition shingle. All stancions and penetrations to be flashed with UL Approved flashings. 170- Roof Mount Detail 1. Pro-Solar Fast Jack Stancions 2. Flush mounted in one group of 3 panels 3. Sized for wind loads up to 120 mph 4.Array weight is 2.20 Ibs/sqft. Panel Weight: 38 Ibs. # of panels 3 Total panel: 114 Ibs Rack weight: 18.5 Ibs Total Weight: 132.5 Ibs Area: 60.0 sqft Loading: 2.20 Ibs/sqft Ad el man Residence Cam/no Hills Drawn By; Michael Cornelius Signed: North County Solar 1039 La So/ana Drive. Fallbrook, Ca. 92028 C46 #864713 760-695-8802 760-695-8803 Roof Mount Details 2298 Bryant Drive Carlsbad, Ca.92008 APN# 212-101-44-00 Skyline 2001 thermal collectors 60 sq ft. E Tech RO60 Hot Water cube Condensate drain to outside of building T&P relief to outside of building 3/4" copper pipe Storage tank w/ out heat exchanger AntiScald valve T&P relief to outside of building 3/4" copper pipe Storage tank w/ heat exchanger > Hot water out Existing Seisco instantaneous water heater NOTE: All drains to outside of building terminate in a landscaped area or drain. Adelman Residence Cam/no Hills Drawn By; Michael Cornelius Signed: *•••••• • • North County Solar 1039 La So/ana Drive. Fallbrook, Ca. 92028 Plumbing schematic C46 #864713 760-695-8802 760-695-8803 2298 Bryant Drive Carlsbad, Ca.92008 APN# 212-101-44-00 AJOf^TM Coo A/TV • •* • •• » •• • ••• • • •• • • Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat... Page 1 of 1 Department of Consumer Affairs —*» ^ Contractors State License Board Contractor's License Detail - License # 864713 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. • CSLB complaint disclosure is restricted by law (B&P_7J_24_.6). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. • Per B&P 7071,17, only construction related civil judgments reported to the CSLB are disclosed. • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. • Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number: Business Information: Entity: Issue Date: Expire Date: License Status: Classifications: Bonding: Workers' Compensation: 864713 Extract Date: 02/18/2010 NORTH COUNTY SOLAR 1039 LA SOLANA DRIVE FALLBROOK, CA 92028 Business Phone Number: (760) 695-8803 Sole Ownership 09/24/2005 09/30/2011 This license is current and active. All information below should be reviewed. CLASS DESCRIPTION C46 SOLAR CONTRACTOR'S BOND This license filed Contractor's Bond number SC1040814 in the amount of $12,500 with the bonding company AM£RiCAN CQNTRACTQRSJNDEMNJTY COMPANY. Effective Date: 03/02/2009 Contractor's Bonding...History This license is exempt from having workers compensation insurance; they certified that they have no employees at this time. Effective Date: 08/24/2005 Expire Date: None Personnel List I Salesperson List Conditions of .Use | Privacy. Policy. Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicense/LicenseDetail.asp 02/18/2010 CB100289 2298 BRYANT OR ADELMAN RES-NEW PHOTOVOLTAIC & SOLAR HOT WATER SYSTEMS-ROOF MOUNTED ON Approved I BUItDING PLANNING 7 ENGINEERING FIRE 3-/4-/Q Health Date TV IJL//0 Forms/Fees Encina Fire HazHealthAPCD PE4.M CFD: Y N LandUse.-ImpArea: FY: Comments Date Date Building Planning Engineering Fire Need? Application Complete? Fees Complete? N N By. By