Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2303 OCEAN ST; ; CB150744; Permit
City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-14-2015 Commercial/Industrial Permit Permit No: CB150744 Building Inspection Request Line (760) 602-2725 Job Address: 2303 OCEAN ST CBAD Permit Type: TI Sub Type: COMM Parcel No: 2030102200 Lot #: 0 Valuation: $16,245.00 Construction Type: SB Occupancy Group: Reference # Project Title: OCEAN ST. CONDOS: 375 SF BUILD SALES CENTER Status: ISSUED Applied: 03/10/2015 Entered By: JMA Plan Approved: 04/14/2015 Issued: 04/14/2015 Inspect Area Plan Check #: Applicant: JIM MCMENAMIN 858-705-0242 Owner: OCEAN STREET 8 OWNER LLC A1TN:GENERAL COUNSEL 3300 P G A BLVD #820 PALM BCH GDNS FL 33410 Building Permit $175.93 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $123.15 Meter Fee $0.00 Add'I Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $4.55 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $0.00 Add'I Renewal Fee $0.00 ELECTRICAL TOTAL $0.00 Other Building Fee $0.00 MECHANICAL TOTAL $0.00 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB1473) Fee $1.00 HMP Fee ?? Fire Expedidted Plan Review $0.00 Green Bldg Standards Plan Chk ?? TOTAL PERMIT FEES $304.63 Total Fees: $304.63 Total Payments To Date: $304.63 Balance Due: $0.00 /11 / FINAL APPOV/AL Inspector: V 11111/" Date: /t'/ L/ 24.)1 L' Clearance: Jl I NOTICE: Please take NOTII 1!E that proval of your project includes the lmpositicn" of fejes, dedications, reservations, or other exactions hereafter collectively referred to as feesIexactionf You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedureset forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: EJPLANNING DEPIGINEERING - DBUILDING EJFIRE EJHEALTH DHAZMATIAPCD I %b, City of Building Permit Application .1635 Faraday Aye., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 C3.risbacI . email: building@carlsbadca.gov www.carlsbadca.gov Plan Check No. C13L S O7/ ' Est. Value /, Plan Ck. De osit Date .3 7 1011T Iswppp I JOB ADDRESS 3O3 e2ti_ 5f SUITE#/SPACE#/UNITC APN - - . - CT/PROJECT a . LOT # PHASE C IC OF UNITS C BEDROOMS C BATHROOMS TENANT BUSINESS NAME f CONSTR. TYPE OC GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) - 51ej ce EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) I FIREPLACE I'ESD#. NO 'AIR CONDITIONING YES DNO IFIRE SPRINKLERS YESD NOE APPLICANT NAME Primary Contact PROPERTY OWNER ADDRESS ADDRESS Cliv STATE ZIP CITY STATE ZIP PHONE rr 7DS. PHONE . FAX EMAIL ,m. t CEMAIL . DESIGN PROFESSIONAL CONTRACTOR BUS. NAME ADDRESS . ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL STATE LIC. C STATE LIC.# . CLASS Cliv BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or reoair any Structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapte(9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: ElI have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. F-11 have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date Thi section need not be completed if the permit is for one hundred dollars ($100) or less. tn -. Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages as provided for in Section 3705 of the Labor code, Interest and attorney's fees. CONTRACTOR SIGNATURE . . . 0 AGENT DATE (Q(DDP)@W I hereby affim, that lam exempt from Contractor's License Law for the following reason:' I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sate (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employeesi provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who buildsor improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law). [] I am exempt under Section _____________Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement Dyes [:]No 2.1 (have! have not) signed an application fora building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address/phone/contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address/phone! contractors' license number): I will provide some of the work, bull have contracted (hired) the following persons to provide the work indicated (include name/address/phone! type of work): .'PROPERTY OWNER SIGNATURE . []AGENT DATE G®Q UM08 O®IZ) (®( 000()000 WlO'O ®J Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the PresIeyTanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. G®!)?O®1I øO® 00003V I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (I) Civil Code). Lender's Name Lender's Address advaoliamy eamuopoisavoom Icei1ifjthatI have ad the application and slate thatthe above Information tecenactand thatthe information on the plans lsaccwate. lagmalacomplywlth all Cityordinances and State laws mtatlnglabulldlngconsimclion. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA. An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3stories in height. EXPIRATION: Every permit issued by the Building Olfcial under the provisions of this Code shall expire by runitadon and become null and void if the building orwsrk authorized by such permit is not commenced within 180 days from the data of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced bra period of 180 days (Section 106.4.4 Uniform Building Cede). ..'APPLICANT'S SIGNATURE DATE 9 —' STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CEnTIFICATE OF OCCUPANCY fCommercia I Projects Only) Fax (760) 602-8560, Email bUiIdina(äCarIsbadca.pov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pt 1) ASSOCIATED CB# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pt 1) NO CHANGE IN USE / NO CONSTRUCTION MAIL! FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION GNATURE lt~ DATE Inspection List Permit#: CB150744 Type: TI • COMM OCEAN ST. CONDOS: 375 SF BUILD SALES CENTER Date Inspection Item Inspector Act Comments 10/05/2016 89 Final Combo - RI 10/05/2016 89 Final Combo PY AP 09/21/2016 89 Final Combo PY NR 09/20/2016 92 Compliance Investigation PY P1 Friday, October 07, 2016 Page 1 of 1 <44 CITY OF CAR LSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carIsbadca.ov DATE: 3/26/15 PROJECT NAME: Ocean St. Residences PROJECT ID: CT 05-12 PLAN CHECK NO: CB 15-0744 SET#: I ADDRESS: 2303 Ocean St. APN: This plan check review is complete and has been APPROVED by the Planning Division. By: Shannon Werneke A Final Inspection by the Division is required D Yes . Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-6024610 760-602-2750 760-602-4665 Chris Sexton Chris Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov ChristoDher.GIassen©carIsbadca.ov Greeorv.Rvan@carIsbadca.gov Gina Ruiz ValRay Marshall Cindy Wong 760-602-4675 760-602-2741 760-602-4662 Gina.Ruiz©carIsbadca.ov ValRay.MarshaII@carIsbadca.gov CynthiaWonp@carIsbadca.gov Shannon Werneke 760-602-4621 Shannon.Werneke@carlsbadca.gov LII Linda Ontiveros 760-602-2773 Dominic Fieri 760-602-4664 Linda.0ntiveros@carIsbadca.gg Dominic.Fieri@carlsbadca.gov Remarks: None February 26, 2015 Building Department City of Carlsbad Carlsbad, CA RE: Ocean Street Residences Delta D - Owner Revisions CA1.2 Revised parking adjacent to Stair/Elevator 1 t provide accessible parking space for Sales Center. Added site security access gates. Noted knox boxes at all security access gates. Revised keynote 25 and added keynote 29A. Added panic hardware and tactile exit sign callouts. CA1.3 I Removed stairs and sidewalk between Ocean Street and Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added site security access gates. Noted knox boxes at all security access gates. Revised keynote 25 and added keynote 29A. Added panic hardware and tactile exit sign callouts. A1.1 Removed stairs and sidewalk between Ocean Street and Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street, Added vehicular access gate and revised keynote 914. A2.2 Revised parking adjacent to Stair/Elevator i to provide accessible parking space for Sales Center. A2.3 Removed stairs at Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added site security access gates. A2.6b Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. A3. la Revised Den I Optional Bedroom to Sales Office and added entry door. Added security access gate and revised entry porch. E4.0 Revised site lighting. Sincerely. Jonathan Shapero, AlA Architect 539 South Cedros Avenue +1-858-350-0544 WWW.DAHLINGROLJP.COM Solana Beach, California 92075 USA + 1-858.350.0540 fa February 26, 2015 Building Department City of Carlsbad Carlsbad, CA RE Ocean Street Residences Delta D - Owner Revisions ( CA1.2 \ Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. i Added site security access gates. Noted knox boxes at all security access gates. Revised keynote 25 and added keynote 29A. Added panic hardware and tactile exit sign callouts. CA1.3 .Removed stairs and sidewalk between Ocean Street and Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added site security access gates. Noted knox boxes at all security access gates. Revised keynote 25 and added keynote 29A. Added panic hardware and tactile exit sign callouts. A1.1 Removed stairs and sidewalk between Ocean Street and Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added vehicular access gate and revised keynote 914. A2.2 Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. A2.3 Removed stairs at Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added site security access gates. A2.6b Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. A3.1a: Revised Den / Optional Bedroom to Sales Office and added entry door. Added security access gate and revised entry porch. E4.0 Revised site lighting. : Sincerely, Jonathan Shapero, AlA Architect 539 South Cedcos Avenue +1-858-350-0544 WWW.DAHLINGROUP.COM Solana Beach. California 92075 USA + 1-858-350-0540 tax February 26, 2015 Building Department City of Carlsbad Carlsbad,. CA RE: Ocean Street Residences Delta D - Owner Revisions (CA1.2'\ Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. Added site security access gates. Noted knox boxes at all security access gates. Revised keynote 25 ,------.-....and added keynote 29A. Added panic hardware and tactile exit sign callouts. ç,cA1.3:.: )emoved stairs and sidewalk between Ocean Street and Buildings, 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added site security access gates. Noted knox boxes at all security access gates. Revised keynote 25 and added keynote 29A. Added panic hardware and tactile exit sign callouts. A1.1 Removed stairs and sidewalk between Ocean Street and Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added vehicular access gate and revised keynote 914. A2.2 •. Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. A2.3 Removed stairs at Buildings 2, 3, 4 & 6 and revised ramp access from Ocean Street. Added site security access gates. A2.6b Revised parking adjacent to Stair/Elevator 1 to provide accessible parking space for Sales Center. A3. la.. Revised Den / Optional Bedroom to Sales Office and added entry door. Added security access gate and revised entry porch. E4.0 Revised site lighting. Sincerely, Jonathan Shapero, AlA Architect 539 South Cedros Avenue +1-858-350-0544 . WWW.DAHLINGROUP.COM Solana Beach. California 92075 USA + 1.858-350-0540 tax EsGil Corporation In Partners/lip wit/I covernment for Buiffing Safety DATE: 03/30/2015 JURISDICTION: Carlsbad PLAN CHECK NO.: CB15-0744 SET: II PROJECT ADDRESS: 2303 Ocean St. U APPLICANT U PLAN REVIEWER U FILE PROJECT NAME: Sales office TI for optional bedroom 3 "Temporary" The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. EJ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. LI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person REMARKS: Applicant to slip sheet all revisions to original plan set By: John Le Vey Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 03/23/2015 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CB 15-0744 03/30/2015 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: CB15-0744 PREPARED BY: John Le Vey DATE: 03/30/2015 BUILDING ADDRESS: 2303 Ocean St. BUILDING OCCUPANCY: R3 BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Revisions to PCR 13-30 per city 16,245 Air Conditioning Fire Sprinklers TOTAL VALUE 16,245 Jurisdiction Code Icb I By Ordinance Bldg. Permit Fee by Ordinance v Plan Check Fee by Ordinance Type of Review. El Complete Review U Structural Only I $176.681 I $114.841 U Repetitive Fee , I Repeats El Other El Hourly Hrs. @ * EsGil Fee I $98.941 Comments: Sheet of macvalue.doc + S .á EsGil Corporation In (Partnership with government for 8u1(iing Safety DATE: 03/19/2015 JURISDICTION: Carlsbad PLAN CHECK NO.: CB15-0744 SET:I PROJECT ADDRESS: 2303 Ocean St. PROJECT NAME: Sales office TI 0.APPLICANT JURIS. '01 U PLAN REVIEWER U FILE El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Jim McMenamin ate con)acted: f ' (by\1'-) /tji'aii t4e1eph0ne Fax In Person 111 REMARK'' By: John Le Vey EsGil Corporation GA DEJDMB DPC Telephone #: 858-705-0242 Email: jim©zephyrpartners.com Enclosures: 03/12/2015 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CB 15-0744 03/19/2015 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: CB15-0744 OCCUPANCY:? TYPE OF CONSTRUCTION: ? ALLOWABLE FLOOR AREA: SPRINKLERS?: ? REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 03/10/2015 DATE INITIAL PLAN REVIEW COMPLETED: 03/19/2015 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: ? ACTUAL AREA: ? STORIES: ? HEIGHT: ? OCCUPANT LOAD: ? DATE PLANS RECEIVED BY ESGIL CORPORATION: 03/12/2015 PLAN REVIEWER: John Le Vey This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CB15-0744 03/19/2015 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Please provide a copy of the construction value cost for the proposed work Please provide details for the revised parking Please provide construction details for the ramp Provide complete construction details for the new construction of the sales office Please provide a door schedule and hardware for the doors Please provide a complete description of the work on the plans "Scope of Work" Please clarify it appears this work is possibly a revision for an existing permit, if so provide the approved set of plans "complete", if it is not and to a project that is completed please provide "complete" plans. I have nothing to compare the project to Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Occupancy Classification(s) For Mixed Occupancy Buildings, state whether the "nonséparated" or "separated" option was chosen from Sections 508.3/508.4. Description of Use Type of Construction Sprinklers: Yes or No Stories Height Floor Area Occupant Load Justification to exceed allowable area in Table 503 (if applicable) Justification to exceed allowable height or stories in Table 503 (if applicable) Carlsbad CB15-0744 03/19/2015 Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2013 California Building Code, which adopts the 2012 IBC, 2012 UMC, 2012 UPC and the 2011 NEC. For plans submitted for plan check norir7/11iA'4, provide a Prescriptive or Performance energy design, demonstrating compliance with current 2013 energy efficiency standards. Information and Forms are available at: www.enerqy.ca.qov/t1t1e24/201 3standards. . ELECTRICAL Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations. Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. Indicate wiring method, i.e. EMT metal flex. A GFCI protected receptacle outlet is required within 25 feet and on the same level as the mechanical equipment (heating, air-conditioning, and refrigeration equipment). Please include on the plans. NEC 210.63. . MECHANICAL Show the location, type and size (BTU's) of all heating and cooling appliances or systems. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. Detail access and working clearances to HVAC equipment. Detail ladder access to roof mounted HVAC equipment. Detail disposal of main condensate drainage from air conditioning units. 0 PLUMBING Carlsbad CB 15-0744 03/19/2015 24. Per California law, additions or alternations of Commercial projects or Multifamily Residential projects (condos, apartments and hotels with kitchens) available for use before January 1, 1994 may require replacement of noncompliant plumbing fixtures *** by water conserving fixtures: All plumbing fixtures in the building where an addition will increase the floor area of the building by 10%. -(Or) Plumbing fixtures that serve the alternations or improvement, in which the building permit valuation exceeds $150,000.00. (Or) An alternation or improvement to a room containing noncompliant fixtures (regardless of valuation). Please note on the plans the specific plumbing fixtures requiring replacement. "Noncompliant plumbing fixtures" are any of the following: Any water closet exceeding 1.6 gallons/flush. Any urinal manufactured to use more than 1.0 gallon/flush. Any showerhead exceeding 2.5 gallon/minute. Any interior faucet that emits more than a 2.2 gallons/minute. 25. Provide complete plumbing plans, including: Complete drain, waste and vent plans. Provide gas line plans and calculations, showing pipe lengths and gas demands. Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. Show water heater size, type and loôation on plans. 26. Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. 27. Show 1/4" per 12" slope on drain and waste lines. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Carlsbad CB15-0744 03/19/2015 Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact John Le Vey at Esgil Corporation. Thank you. (a. 3 Carlsbad CB 15-0744 03/19/2015 [DO NOT PAY — THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: CB15-0744 PREPARED BY: John Le Vey DATE: 03/19/2015 BUILDING ADDRESS: 2303 Ocean St. BUILDING OCCUPANCY: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) No billing at this time awaiting construction value cost Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I I UN/A I Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance I #N/AI I #N/AI Type of Review:. LJ Complete Review fl Structural Only El Repetitive Fee El Other vj Repeats El Hourly EsGil Fee Hr. © * I #N!AI Comments U, addron to thve fee, an additional fee of $ ls due( hour( I A-1 --/h-r.)jq[tke~_qaIGreen review. Sheet of macvalue.doc + I CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL BUILDING DEPT Comr OF conomic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 03/26/2015 PROJECT NAME: OCEAN ST CONDOS PROJECT ID: CB150744 PLAN CHECK NO: I SET#: I ADDRESS: 2303 OCEAN ST This plan check review is complete and has been APPROVED by the FIRE Division. By:GR A Final Inspection by the FIRE Division is required Z Yes 0 No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: JIM@ZEPHYRPARTNERS.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-6022750 760-602.4665 Chris Sexton Kathleen Lawrence Z Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chrls.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov [ Gina Ruiz [ Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cvnthia.Wong@carlsbadca.gov Eli 'Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov P COMM. Carlsbad Fire Department Plan Review Requirements Category: TI , COMM Date of Report: 03-28-2015 Name: JIM MCMENAMIN Address: 0~ ji~l Reviewed by: 4 Permit #- CB150744 Job Name: OCEAN ST. CONDOS: 375 SF BUILD Job Address: 2303 OCEAN ST CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0008 138 [NOT MET] Provide the correct information for each of the following items: Occupancy:? Type of construction:? Allowable floor area: Spriniders?:? Jurisdiction: Carlsbad Use:? Actual area:? Stories:? Height:? Occupant load:? Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. Please note on this list where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Please provide construction details for the ramp (rise and run) Provide complete construction details for the new construction of the sales office (type?, rated?, Separated?) Please provide a door schedule and hardware for all doors. Please provide a complete description of the work on the plans under "Scope of Work" Provide a Building Code Data Legend on the Title Sheet. Include the following code information for the proposed building: Occupancy Classification(s) For Mixed Occupancy Buildings, state whether the "non-separated" or "separated" option was chosen from Sections 508.3/508.4. Description of Use Type of Construction Sprinklers: Yes or No Stories Height Floor Area Occupant Load Justification to exceed allowable area in Table 503 (if applicable) Justification to exceed allowable height or stories in Table 503 (if applicable) Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2013 California Fire Code as well as the 2013 CBC, which adopts the 2012 IBC, 2012 UMC, 2012 UPC and the 2011 NEC. ELECTRICAL Submit plan showing location of all panels. Submit panels schedules: Indicate new additional loads. Indicate wiring method, i.e. EMT, metal flex. A GFCI protected receptacle outlet is required within 25 feet and on the same level as the mechanical equipment (heating, air-conditioning, and refrigeration equipment). Please include on the plans. NEG 210.63. MECHANICAL 15. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. Entry: 03/28/2015 By: GR Action: CO