HomeMy WebLinkAbout2304 Levante St; ; 86-227; Permit,,,
z 0
" • .. • ~ u "' 0
..
iL
81
..
"' 0 ~ 3 ~ "' z ~ 0
'
O I hereby affirm that I am licensed under
provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Professions Code, and my license 1s 1n
full force and eflect
L,c Ne--~----c,a,
he·eay o'l1'rn •nor '·:-rr ·ne
·r,r', L1ce~se Lew tJr the 'lu,,ness and P·oless,c,"; Coce
<:,:i·es a per-,,: to V'."S!ru~t o
·epa,r any struC'uce ,"s
p ,cast f:ir SU(.~
1 ~ensed
a, Jw•·er J' t",e r;ropec··,·. or '°)' err~ J)"ee·, ,, T' ;.,aoes
11e,r so'e co~1per3;iT101 ;.,1h ac, lhll -.-,:;·k ,,-j ·1e s'""t
,s r1c1 ,nterded or Jl'ered fc-· sale !Sec 7'J~l ~w a,c 0,n:ess,cr,s Coce '1e Cuntracl:;r s L cer,se uw
•,ol apply le an owner ,Jf pr:ipe·Ty w~o h-,11ds ur morn,es
tt·.ereor ar'd who does such work r.,mselt or !hrouu, h·s Jwn
emplcyees, p·:;-1,ded tr~: such ,r~·o-,erner,ts ,l'e no: 1n1erd
ed or OlfereG tor sa e 11 however the ~,1'd1r~ or 1n"O'Ove "'lent 1s so,d w,trn one year of comolet,on the owrer-ou,lcer
. ...,, , ha,e The OJ'de~ ot orov,ng that he a,d no: Cu1,c c, m
wc,·e for '.he ouroVie of sale1
I as owne, Jf The prJperty, am enlus,·,ely c,:;r1Trdct1°g
..,-,rn -1(.ensed cert, acto's tc constru~t lhe oro1r.ct 1Sec 7J44 Business and Proless,ons Code The Con:rocTor'o License
I a·;., does 10: aopl·, tu il~ owner ~t prsper!y wno b.;; ds or ,rn prove; thereun. and wno coorrac1, lor eac". p'o1ec~ w,t~ a
contracw;s1 ,1cense oursJanT to the Cortr;;ctor s L,ce-.se Law I
As a horneowrer I a~. ,rnorov11•; ry hJ~f. end the !cl rJ;.' ,,g conu,t,ons e~ist
, The wcr, ,s be,nq oe,formed pr,or :o sa1e
2 I r.ave lived ,n 11y ~o'!le for twel·,~ mo"trs
p',or to corq,1e11on of !his l'IOrk
l I have rot cLa1med This e,ernol<On dari··g ·nr.
lasl t~ree yeJrs
I ;im e~e.mpt •"nder Sec lor tms reason ____________ _ B & PC
"' "' " "' 0 ~
__ I he·eby af<,rr,i \ha\ I oa,·e a cert,licate of consent 10
sel'-,%ure or a ce-t,"cate of Workers Compensat,M In
Sl-r,,nce o· ~ ccrt,',eG cJ~•·, thereof ,Se~ 3500 Labor Code,
Co~-, s t, ed ·;,, t~ the c,ty
Cert,f,ec cc~y ,s hereby furn,shed
CERTIFICATE OF EXEMPTION FROM
WORKERS COMPENSATION INSURANCE
1Tr.,s section need 10\ be conpleteo ,t the perm,t
,s for one hundreo Oollars ,,$1001 or less,
_ I cer1'1; that ,n the performance cf the work for ·;;h,ch
th,s Permit ,s ,ssued. I shall not employ any pe'SOP "' an1 •nanner so as to become sub1ect to the Workers Co,npen-
sat1on Laws ol Callforn,a
NOTICE TO APPLICANT If after making th>s Cert,t,cate
cit Exemption you st>ould become sub1ect to the Workets
Compensat,on prov,s,ons of the Labor Code you IY'ust
L forthw,th comply w,11> such pro,is,ons or this eerm,t shall
be deemsd revoked
![ _ I herel:Jy aff,rm that there ,s a construction 'ending
agency 'or1he pe,lormance of the v,o,k forwh,ch th,s per
m,t 1s ,ssued (Sec 3097 C,v,I Code1
Le~der s Name
Le~der s Adc>ress
, r'tN UNLT & t'tct:,:, MRKU CARLSBAD BUILDING DEPARTMENT
Carlsbad. California 92008·1989 \6191 438-5525 APPLICATION & PERMIT
L
~~NESSLICENSEt:r. ···~·-· 1 AV.ST.RD NEARESTCROSSST. , fJ}•
; Lev .r.v Te. .St ORR f o,J CONTRACTORS ,HONE •
CONTRACTOR /
COT BCOCK SUBo,v,S,QN ~ (2,)../~"c cc~✓f;12.UcT, "7Z-C/-5b0
I
: OWo-,;.;M~'e-pV92-/6 c~;;~s'd;;t~B o'J-int:=:tq: L~;·;;;4
: OWNEy'q"l;n;_;~ c#2. ~,,-,i-Jee~ (/J, z;;,~c;,12.lc_,,, Dz,:;;~;
I DEScA:PTION OF WORK DESIGNER'S ADDRESS '1-----------------:--------, I
LICENSE NO.
PERMIT r-.UMBER VA LUA I IU"I
3:Z..33i:Z j7t-,J,). 7 ZONE
PLAN 1.0. ,,_ I BUILDING 50 FOOTAGE
53&
··:c ..
I ,L C rJ ,,.u_ ~-r re.." c-f' D11pleX NO OCC GP EDU
r· ~
6/24 /SC 1
l I [is ( /~L: i :-''.) !T':-v .. -:-:t;
C e F LR ELEV
STORIES /2 °<' -,
! -~ -...[J --,/ .,,,_
j Cl'\i':,USTRACl (>PLA"-OUS~ f'A<=lK'Nr,SPAC~ R!:SUNITS GRADING PERMIT ISSUED <=lEOEVELOPMEI\JT OCCLOAO FIRESPFI
~ AREA
I / t) ,.7\. y D ~ O , :J -.. y O Not Valid Unless Milchine Cer11f1ed
. -·~ ' OTY.i PLUMBING PERMIT. ISSUE MECHANICAL PERMIT -ISSUE _3 SUMMM'lYl~CCOUNT NUMBER
I 1--,~.,f-------------------'-~-~;--~~+----------------+~c.,.~~-+ -=====;---'-.o=,"':J€.~oei-,;;;cic·cw,ce-r-----,".lt,-,
EACH FIXTURE TRAP___ ___ ___ __ _.{>_{ INST All FURN OUC1S iJP HJ 100 000 BTU ./ BUILDING PE9M;T "s¼T~Jf-00-_~0-82~ __ ~ -
1 fACH BUILlJING_?EW~R -~-/~~ __ ·:. • OVER 100 000 BTU SIGN_PEfiM\1 _ 0~~!~-□~~0:_8221 ___ _
I EACH l/11ATER HEATER AMI OR VF!IJT _ -----+--~ f _ i BOl~ER COMPRESSOR UP TO 3 HP -----+----PLA~t0i_t.~~ --~·8_~~1'J0§!:06 fbL/~-~
\ EACH~_ASSY_STE~,1 JlJ.1LlUILE'TS S",.,,,,... -➔i ~BOILER COMPRESSOR31'iHP ___ TOT~-~~UMB~r-OOi:810-00-· 3) ?7-
1 \.H'Vil ~ ../ff! AC::. . ELECTR1CAL . ,, 001"810·,00-00-8223 S--S---
: 1:.ACH INST Al ALTE:R REPAIR 1'-.'Al FH PIPE' --~ -~-!VENT !AN -SINGLE n-UCT _ --?" ~~ ~CHANICAL-~_
0
~_--~ __ -o-_i-l-~81·;:~-0-0-□·8224 --~--q----===== 1, __ EACH [;AS SYSTl:.M 'i OR .,_,,[Jf-]f
EACH VACUUM BREAKER • MECH EXHAUSl HOOlJ lJUCTS MOBILEHOME O!lHl0-00·00-8225 >----+---------------------+----------,
·-------0ATER SOFT~~ ___ ____; _____ -+ RELOCATION OF EA FURNACE-HEATER _ ---j-----MOBILEHOME PARK Ir-SP
: j ,,,~ C ~i R/ / ''--~---l-~T TOT kl MECHANICAL / !~~~:G MOTIO~ OOHJ;i::~~~~:~~~ L
• !()T,'\,l P\iJ"'11-llN[, l '67 Y-i ____ . -----~~--~~---~ l'i -~l~SPRl~r\LERS 001·810-00-00-8227
7--Y~
: ELECTRICAL PERMIT -1ssuE f -j' OTYI SOLAR. 1ssuE PUBLI_~ FAc1:,11!? FEE 332 810 00 QQ__§93ot. -_ . ~-· _________ _.LLr-..,_ ___ ...il...2~r __
NEW CONST 1:.A AMP W,'l f-lKR ~ -----r:o.L~C'O;::s -----______ .J_ ___ --SCHOOL FEE -DISTRICT -
l PH .l PH:-----=---~ ____ 11 SF'·RA,3~ lA';VS Carlsbad
--+-'-'_1s1 bLDG 1:.AAMPSWr-~~~ s-p ~--riuc" s::RAGE ___ _
\ PH :l P~-----= . I I P'Jr-/F I ,---REMODEL AL Tt:R PER [IRCUIT
---
r· t,,\J ()-ff(), ~t:E __ / __ _ -.---------+-
----u-
--Enc1n1tas
~~u_1to _____ _
Sar, Marcos
-~
--------+--------
-
'
TE¥PPOLE 2UOAMPS I ---t--i
1-----+---o~~R zuu A_MPS I -------LICENSE TAX _S' 001 810.00_00_8162 ~ -
T£ MP O C [UPAN CY '30 0 A YSI -----i__ ___1 --.. -------+------M~F~(J/ D 880-519·92-57 +~"--"'-'~'----I
' 1-------------~--~-r ' _ ______ __ CREDIT DEPOSIT ---i--,.~ ;;r_;_.;. '>
: I Till Al EllUHILA! s-:;-WAC S'1>'' 1 ---TOTAL FEES PAYABLE tJ:2.. 96 .. rr
I HAVE CAAEFULL Y·EXAMINED THE COMPLETED --APPLICATION AND PE:RMIT" AND DO HEREBY CERTiFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE * AN OSHA PERMtT IS REQUIRED FOR EXCAVATIONS OY
1 DECLARATIONS ARE TRUE AND'CORRECT ANO l FURTHER CERTIFY ANO AGREE IF A PERMIT IS 5· 0" DEEP ANO DEMOLITION OR CONSTRUC:TK>N Of
I ISSUED: TO COMPLY WITH ALL CITY. CQUNl Y AND STATE LAWS GOVERNING BUILDING CON• STRUCTURES OVER 3 STORIES IN HEIGHT
STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND
1 KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS. COSTS AND ,-7'"'--. APPROVED BY 0%,
1 EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ~~~i:,..CA'""'.r • "-------~ /,
GRANT1NG OF THIS PERMIT , I y 3 J(h
§ ~-
l
-" u.
"' d 0 0.
E ill
f-
0 u
C m
0 c. ·: I
~ ""
1
C n:
0 " " w " " "'
< 0
w >-
,i
" ill 0 0 a:
~ ;;
0
fa.
w 0 C ro C
u.
-
C w
~ u
0 u w 0. ,
-'=
2'
re ,:
TYPE , DATE INSPECTOR
BUILDING :
FOUNDATION ....._ .,.,
REINFORCED STEEL , "-.. ;;;, /-, / ,,,, 7'"" (;4'
MASONRY 1
' ' I
GUNITE OR GROUT '
SUB FRAME □ FLOOR □ CEIL.ING
SHEATHING □ ROOF □ SH:EAR -
FRAME ' ,.,;·-/;, r-'_
EXTERIOR LATH , ,,;_//J/1-, //I
INSULATION : /}/..I /. /1
INTERIOR LATH & DRYWALL 1 ·' ''/Y'f ,,.._,
, I
I
PLUMBING I
□ SEWER AND BL/CO □ Pl/CO
UNDERGROUND □ WASTE □ ,WATER -
TOP OUT □ WASTE □ WATER ' ,~;1• • ,-
TUB AND SHOWER PAN , ' ' .,.,
GAS TEST , • / -h, 1-f--/
□ WATER HEATER □ SOLAR WATER ' 1
I
ELECTRICAL ;
□ ELECTRIC UNDERGROUND □1 UFFER A
ROUGH ELECTRIC 1 //~-1/.n "7"
□ ELECTRIC SERVICE □ TEMPORARY ' 1 '
□ BONDING □ POOL 1
I
MECHANICAL ; /J
□ DUCT & PLEM., D REF. PIPING ///; 7 / >t. 17-'
HEAT -AIR COND. SYSTEMS , 1
VENTILATING SYSTEMS :
I
CALL FOR FINAL INSPECT/ON WHEN ALL APPROPRIATE
ITEMS ABOVE HA\IE BEEN APPROVED
FINAL '
PLUMBING ' I
ELECTRICAL "' I fl
MECHANICAL ' I .J/ I
GAS ,,
" 11 I
BUILDING ,, 'L I' .
SPECIAL CONDITIONS I ' ' ' '
,-C'"" (--··-· ----------------..
J£ :JJ
FIELD INSPECTION RECORD
REOUIREU SPECIAL INSPECTIONS INSPECToR·s NOTES
INSPECTION REO IF INSPECTORS DATE ~ "J,, ~-" L7/ ,A ~ I /"/(/ JI ~ r-ZJ Pn,-"'7 1F A', CHECKED APPROVAL LJ cf
SOILS COMP1• IANCE ' -vaP ~ n -"Th , ~ < -r,,.d , ,, ,:-;,&""'--
PRIOR TO I "k._ .-4. -/"I~,, -/J F-OLJN□ATION 1r,,..5p ' -------------<-----I JI. ~ s>v.c. STRUCTURAi_ CONCRfl E: ~1c. / /2. t I•, T _,., OVER 2000 F-'SI ~,I~~;._,
PRESTRESSET , I I
CONCRETE i
POST TENSIONED
cor-..CRETE ·----1----
FiEl_D WELD1NC; i -,-----' ------·-
HICiH STRENG Tr~
BOLTS
:::YECIA[ MAS\)Nqy I --t i
--·
p1:_E'.::, C.Ai~SUi'-..~ ---L---+· ·----
·~ .. ---~ . -
·-·---. .. ~
--------------r--.. ---~·~
~--·· ------"-----1---~------I-------
--------i-------------r---------
I
j
'
: ,·
' -,
i
I
-
~--------__l ---·~-·~
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 7 DATE: "-1
PROJECT NAME: ----------------------------------
ADDRESS: 304/
PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.:
TYPE OF UNIT: duo NUMBER OF UNITS:
CONTACT TELEPHONE: __ 7_9_5_0_0 _________________________ _
INSPECTED DATE
~3/4/APPROVED ~ DISAPPROVED BY: INSPECTED:
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
COMMENTS: -----------------------------------
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineer! INK: Planning GOLD: Fire
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 7 ' DATE:
PROJECT NAME:
ADDRESS:
PROJECT NO.: UNIT NUMBER: ________ PHASE NO.:
TYPE OF UNIT: .,
CONTACT PERSON:
CONTACT TELEPHONE: n
~y~PECTED~t;lt, DATE 2/Z.d/tf / APPROVED X INSPECTED: DISAPPROVED > /
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
COMMENTS: -----------------------------------
Rev. 1/86 WHITE: Suspense BLUE: Water Dlstrl ARY: Utllltles PINK: Planning GOLD: Fire
ESGIL CORPORATION
9320 CHESAPEAKE DH., SUITE 208
SAN DIEGO, C,\ 92123
(619) 560· 1468
DATE: t:, /;cJ/gc;,
' D AP_P~fCA~1...,...__
filORISDI!;,~;
ITPLANCHECKER D FILE COPY
QUPS
JURISDICTION: C,JJ-12,L-6.!3,q-O
PLAN CHECK NO: 8~ -2 :2 7-_yz;:
PROJECT ADDRESS: 2:s~.,µ-o,;, Lt:V'9N77::.= ;sr, QDESIGNER
PROJECT NAME: 8Lt>::/-';;:.JC.. VUPLE:'}..
□
D
D
D
0
□
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified~--------------are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has ~.e.•en completed.
:ft'\
Esgil staff did'advise applicant that the plan check has_
been completed. Person contacted: §&.,J,UJ/Nq-/?1/?C.h'JVC::
Date contacted:
' Telephone # 7'29 5o:J/
REMARKS: __________________________ _
ENCL: __ ~1?.._1..._1+:_,i_l_.5 __ _
DATE:
ESGIL CORPORATION
9320 CHES,\PE.-\KE OR .• SUITE 208
SAN DIEGO. CA 92123
(619) 560· 14-68
8APPLI~ANT C JURISICTIO}t:)
JURISDICTION: CITY OF CARLSBAD 0 PLAN CHECKER
OFILE COPY
OUPS PLAN CHECK NO: 8(,,, -,Z,Z 7-.Z-
PROJECT ADDRESS: 2.SY.L/-0(,. LEVANTl;F
□DESIGNER
PROJECT NAME:
□
□
□
II
D
•
□
The plans transmitted herewith have been c:orrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified~--=-----~--,=----are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of
NENl'-.D &L1~oe1c.
the check list has been sent to:
fo, Bo~ «, '24-8 0C.'51'r>J$~'QG".
Esgil staff did not advise the applicant contact person that
plan check has been completed;crr~= -r>-t"'"' M<\1~•oJ6r L1si-,
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted:
REMARKS:
BY:~~~~,J
F!GIL CORPORATION
Telephone# ----------
ENCL:~~~
< z) •
8C,-2"27-..r-PIAII aDICII: HO. _.:::::..:::::.-==..:...._;=~--
JURISDlc:rIOR: Cl'IY OF CARLSIIAD
10: ______________ _
'\-\, G L\G-CRl C.
Oc.eA-1-..t S \ 0 {S" C 'AL\ F': '.3 zo 'S' 6, j
Tl!LEl'BlllK HO. , 2. 4 'S"" 00 I
EIICLDSIIRl!S: ------------
(j) 0J'a?/ .. '.-f nJOJ:);f,:;
(1) \5'f\J€'(2.~'..{ v\,,._()<::..,c:i i;,,es
(J) 1122:> ~3 ®S5 '130
PRDJl!CT ADDRl!SS:
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
Applicant contact person:
:a:'.11).!..S' (;~L::..:1.s,bc.,,O:..:.;r2::.:l--=C.,::-_Telephone: 7t=/ 5'00 1
Plan check is limited to technical requirements
contained in the Uniform Building Code, Unifom
Plumbing Code, Uniform Mechanical Code,
National Electrical Code and state laws
regulating energy conservation, noise
attenuation and access for the handicapped.
Toe plan check is based on regulations enforced
by the Building Inspection Department. You may
have other corrections based on laws and
ordinances enforced by the Planning Department,
F.ngineering Department or other departments.
Present califomia law mandates that
residential construction comply with Title 2~
and the following model codes:
1982 UBC (eff. 7/1/85)
1982 UPC (eff. 10/1/85)
1984 NEC (eff. 10/1/85)
1982 UMC (eff. 3/1/85)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
Toe circled items need clarification,
modification or change. All items have to be
satisfied before the plans will be in
conformance with the cited codes and
regulations. Per Sec. 303 (c), 1982 Uniform
Building Code, the approval of the plans does
not permit the violation of any state, county
or city law.
to speed up the recheck process, note on this
list {or a copy) where each correction item has
been addressed i.e., plan sheet, specification,
etc. Be sure to enclose the marked up list
when you submit the revised plans.
carlsbad List 10, Single Family Dwelling and Duplex With All Supplements
1
3/25/86
-~-.
A. PLAllS
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
J--,..,.,eturned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, C&lifornia 92123,
(619) 560-1468.
'{J). Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
J Indicate on the Title Sheet of the plans,
/~e name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302 (a) 7.
Plans, specifications and calculations shall
signed by a C&lifornia state licensed
engineer or architect. (California Business and
Professions Code).
/ Specify on the Title Sheet of the plans the
/g;oss floor area of each element of this project
including dwelling, garage, carport, patio, deck
and balcony. Section 302 (c).
A Provide a statement on the Iitle Sheet of
the plans that this project shall comply with
tle 24 and 1982 UBC, UMC, and UPC and 1984
NEC.
I· Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes and approximate finish floor
elevations for all structures and show
elevations at all lot corners.
Section 302 (c).
@J SB 740. lle,,) L-Au)
2
3/25/86
J Indicate distance from center line of street /4~ alley to property line and distance from
property lines to proposed building.
Section 302 ( c).
~-Walls closer than 3 feet to property lines
shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5. A. Section 1709 (a)).
J6. Projections, including eaves, may not
extend more than 12 inches into the 3 foot
setback from the property line. Eaves over
required windows shall be not less than 30
inches from the side and rear property lines.
Section 1710 and Section 504 (a) and (b).
, / Plastic skylights shall not be installed
~~in 8 1 of an exterior wall located where
openings in such exterior wall are prohibited or
required to be protected.
Section 5207 (a) 7.
11. Projections, including eaves, shall be
l~e-hour fire-resistive construction, heavy
timber or of noncombustible material if they
project into the 31 setback area from the
property line. Section 1710.
i✓. Show location of permanently wired smoke
le~ector, centrally located in corridor leading
to sleeping rooms or above stair if sleeping
rooms are on upper level. Section 1210.
./. A smoke detector shall be installed in the
/~ement of dwelling units having a stairway
which opens from the basement into the dwelling.
Such detector shall be connected to a sounding
device or other detector to provide an alarm
which will be audible in the sleeping area.
Section 1210.
C. ROg1 SIZl!S, IJGHI. Vl!llrILAl'lOR AIIIJ GLAZillG
,J. Habitable rooms, other than kitchens, shall
fo~tain at least 70 square feet of floor area.
Section 1207 (b).
i. Window area must be at least 1/10 of the
floor area and a mini.mum of 10 square feet per
Section 1205 (a). Appears to be deficient in
_(v') Openable window area in habitable rooms
~;;st be 1/20 of the floor area and a minimum of
5 square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. (Section 1205 (a)).
(i;y At least 1/2 of the common wall must be
/?en and have an opening not less than 25 sq.
ft. if light and ventilation is being supplied
from an adjacent room. Section 1205 (a).
,/ Required windows shall not open into a
;;:~fed porch unlesS the ceiling is at least 7
feet and the longer side is at lea.st 65% open.
Section 1205 (a).
.7-!:__ Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (a).
/. No habitable room, other than a kitchen,
shall be less than 7 1 011 in any dimension.
Section 1207 (c).
/. Show that ceiling height for habitable
rooms is a minimum of 7 1 611• Section 1207 (a) .
,/ Show ceiling height for laundry rooms,
k.i.1ways, corridors, and bathrooms is a minimum
of 7'0". Section 1207 (a).
Dimension on the plans, the 3011 clear width
r water closet compartments and 2411 clearance
in front of water closet.
Section 511 (a).
@. Specify safety glazing for glazing in
/hazardous locations such as glass doors, glazing
adjacent to such doors and glazing adjacent to
walking surfaces. Section 5406.
~-Glazing, in the same wall plane as a door,
/ must be safety glazing if within 12" of the door
and less than 6011 above the walking surface,
unless the glazing is leaded on faceted glass.
Section 5406 (d) 7.
y. Glazing in shower and tub enclosures shall
be tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
,,_/ Sleeping rooms shall have a window or
/~~erior door for emergency exit. Sill height
shall not exceed 4411 above the floor. The
window must have an openable area of at least
5.7 square feet with the minimum openable width
2011 and the minimum openable height 2411 •
Section 1204 .
'1,4. A mezzanine is an intermediate floor and
/may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below. The mezzanine floor must have a clear
height of 7 feet, above and below, and must have
the long side open to the room below except for
posts and protective walls or railings not
exceeding 42" in height. Section 1716.
3J{. The loft you show does not comply as a
/mezzanine floor and is, by Unifom Building Code
definition, a story. Section 1716.
\<:,"l""c.14-~ (\ oo\::.. O"j'@:illt/(r e. J'\t'AT. Lutyn,<.,J o~~-
)
"510 -
"7
3
3/25/86
. ''L". ,\~fl
j./ l<liaT TO :DOO tQ F'l':lYY) I '-'1 o2. v\A •
D. l!XllS, S'LURIIAIS, ARD RATI,IJIGS
,fa" Floors above the second story shall have
not less than 2 exits. Section 3303 (a).
,2 Required exit doorways shall be not less
/~ 3611 in width and not less than 61 811 in
height, and shall be capable of opening at least
90 degrees. Section 3304 (e).
ji}}._ Provide 36" high protective railing for . /
/
porches, bal~!-~~? .. ?P.~.-!~~~~-~t~stair P
land" s. Openings between railings s~
less than 611• Section 1711. fa-/ r.-Show how guardrail connection details are
adequate to support 20 pounds per lineal foot at
a right angle to the top rail. Table 23-B.
Ji;) Provide stairway and landing details.
/ Section 3306 (b) & (c).
a. Maximum rise 811 and minimum run is
911.
b. Minimum headroom is 6 1 611 •
c. Minimum width is 30".
@ ill handrails per Section 3306
/satisfy the following,
(j), shall
a. Provide handrail for stairways with 4
or more risers.
b. Handrail shall be 3011 to 3411 above the
nosing of treads.
The handgrip portion of handrail shall
be not less than 1 1/ 411 nor more than
211 in cross-sectional dimension.
(See attached).
4
3/25/86
J!.· Every stairway landing shall have a
dimension, measured in the direction of travel,
at least equal to the stairway width.
Section 3306 (g).
L A door may open over a stairway landing
provided the door, in any position, does not
reduce the clear area of the landing in the
direction of stairway travel, to less than
one-half the required width of the stairway.
Section 3306 (g).
)9. A door may open inward at the top step of a
stairway provided the top step is not more than
7 1/211 lower than the floor level.
Section 3304 (h).
y/-Provide details of winding stairway
complying with Section 3306 (d):
a. Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12
inches from where the treads are
narrowest.
b. Maximum rise is 8 inches •
c. Minimum width is 30 inches.
r-· Provide spiral stairway details, per
Section 3306 (f):
a. Minimum run is 7 1/2 inches measured
at a point 12 inches from where the
treads are the narrowest.
b. Maximum rise is 9 1/2 inches.
c. Minimum headroom is 6 feet 6 inches.
;I. Spiral stairways may not be used for
required exits when the area served is greater
than 400 sq. ft. Section 3306 (f).
)kif'. Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail, show dimension. Section 3306 (f).
f· Provide I.C.B.O. Research Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication shall be done under special
inspection per the approved fabrication plans.
Section 306 (a) 4B and Section 306 (f). J. In buildings over 2 stories in height,
provide 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within 10
feet horizontally of an exterior stairway. An
exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
i: Exterior stairways shall not project into
the 3 foot setback from the property lines.
Section 3306 (n).
The walls and soffits of the enclosed
able space under interior stairs shall be
p otected on the enclosed side as required for
one-hour fire-resistive construction.
Section 3306 (m).
E. R:tXJfi.iG
~ Specify roof slope.
-d. Roof slope is not adequate for roof type
/.;~cified. Table 32-B; Section 3203 (h).
.@ Specify ,JC' Chapter 32.
roof material and application.
ji. Specify I.C.B.O. or U.L. approval number
for roof materials not covered in U.B.C., e.g.,
title, etc., Section 107.
Ts c.o•·
5
3/25/86
;;{.. The maximum slope for a fire retardant
built-up roof, with rock or gravel surfacing, is
3 inches in 12 inches, Section 3203 (e) 2.
r-_ The minimum slope for a fire retardant
built-up roof, with cap sheet surfacing, is 1/2
inch in 12 inches. Section 3203 (e) 3.
G;;:J Specify minimum 1/4 inch per foot roof
/ ;-lope for drainage or design to support
accumulated water. Section 3207 (a), Section
2305 (f) and Section 2511 (d) 6.
~ Show roof drains and overflows.
Section 3207.
56. Provide skylight details to show compliance
/4ith Sections 3401 and 5207 or provide I.C.B.O.
approval number.
I· Plastic skylight must be separated from
each other by at least 4 feet.
Section 5207 (a) 6.
_@. Show attic ventilation. Minimum vent area
/ is 1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and area provided.
Section 3205 (c).
., • IIASOIIK!
-~/. Provide fireplace construction details or
/n:~e construction to be per attached fireplace
standard drawing. Chapter 37.
~/ Show veneer support and connections in
fe~smic Zones 3 and 4, comply with Section 3002,
4, s, 6, and Section 2515 (a) regarding ties and
#9 wire in horizontal joints or show
construction to be per attached sheets
30-1 or 30-2.
6}/. Show height and construction details
ffiasonry walls. Chapter 24.
of all
6jl. Note that cleanout openings shall be
Provided at the bottom of all cells to be grout
filled over 41 in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Section 2414 (a) 8.
6-/. Show floor and roof connections to masonry
.Calls. Connection shall resist 200 pounds per
lineal foot or the actual design load, whichever
is greater. Cross grain tension or bending in
wood ledgers is not permitted.
Section 2312 (j) 3. A.
/4· Provide details for damp proofing the
foundation walls, below finish grade, where
useable space exists on the interior side of the
walls. Section 1707 {d).
Js. Show a minimum 211 air space and flashing
between planter and building walls.
Section 2516 (c) 7.
G. G.\RAGII AIID CARPOR7S
6'. Garage requires one-hour fire protection on
~e garage side of walls and ceiling coD1DOn to
the dwelling. Table 5. B. Section 503 {d).
All elements supporting floor above garage,
eluding walls supporting floor joists, to have
one-hour fire-resistive protection on the garage
side. Section 503 (a).
f Show 1 3/8" solid core self-closing door
for openings between garage and dwelling.
Section 503 {d).
6'. Garages are not permitted to open into a /4~~ used for sleeping purposes. Section 1104.
6
3/25/86
1/. Openings between carport and residence
~~uire self-closing doors and stationary
windows. Section 1214.
y{. Show garage framing section, size of header
over garage opening, lateral cross bracing at
plate line, method of bracing garage front, and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel ratio of height to
width is 3 1/2 to 1. Table 25-I •
r/. Doors may open into the garage only if the
f1oor or landing in the garage is not more than
1/2" lower than the door threshold.
Section 3304 {h).
7/ Provide an 1811 raised platform for any FAU,
/4.~er heater, or other device in the garage,
which may generate a flame or spark, UMC Section
508, UPC Section 1310 (a).
B. POO:NDAr.1011 #QulkDiin.l.S
~· Per soils report, note on the plan the
soils classification, whether or not the soil is
expansive, and note the allowable bearing value.
Section 2905 (c).
,/ The foundation plan does not comply with ~~ soil report recoamendation for this project.
Please review the report and modify design,
notes and details as required to show
compliance.
7/ Provide notes on the foundation plan
{;:;ting the soils report recommendations for
foundations, slab and building pad preparation.
-s----·-··
-/.. The soils report recomoends excavations be
reviewed by soils engineer. Note on the
foundation plan that "Prior to the Contractor
requesting a Building Department Foundation
Inspection, the soils engineer shall advise the
building official in writing that:
l. the building pad waa prepared in
accordance with the soils report;
2. the utility trenches have been
properly backfilled and compacted,
and;
3. the foundation excavations, farmings
and reinforcements comply with the
soils report and approved plan".
/s. Show height of
Chapter 23.
all foundation walls.
/. Show height of retained earth on all
foundation walls. Chapter 23.
ft( If cut or fill slopes exist, show distance
z•foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
4. Note on plans that wood shall be 611 /m~imum above finish grade.
Section 2516 (c) 7.
J. Note on plans that surface water will drain fa~ay from building and show drainage pattern and
key elevations. Section 2905 (f).
;<'-Dimension foundation per U.B.C. Table 29A:
ll£.Qll
S!!12];!orted* Stemw;iU Width Depth
l 6" 1211 1211
2 B" 1511 1811
3 1011 1811 2411
"Foundations may support a roof in addition to
the floors. Where only a roof is supported, use
foundation for one floor.
7
3/25/86
a/". Show foundation sills to be pressure
treated, or equal. Section 2516 (c) 3.
/s. Show foundation bolt size and spacing.
Section 2907 (e). I Specify size, I.C.B.0. number and
manufacturer of power driven pins. Show edge
and end distance and spacing.
Section 306 (f).
j7. If required by structural calculations,
show size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f).
~ If hold downs are required by calculations,
~te on plan that hold down anchors must be tied
in place prior to foundation inspection.
Section 305 (e) 2. J. Show adequate footings under all bearing
walls and shear walls. Section 2907 (b).
Qr/ Show on the elevations, stepped footings Ao~ slopes steeper than 1:10.
Section 2907 (c).
I.· Show minimum 1811 clearance from grade to
bottom of floor joists and minimum 1211
clearance to bottom of girders.
Section 2516 (c). J.. Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
fa.
2411•
Show minimum underfloor access of 1811 x
Section 2516 (c).
j. Show minimum underfloor ventilation equal
to
0
1 sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c).
gs/ Specify that posts embedded in concrete
{hall be pressure treated per UBC Std. No. 25-
12. Section 2516 (c).
I. PIWIDIG
9j. Show wal 1 bracing. Every exterior wood
/stud wall and main cross partition shall be
braced at each end at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3.
ch. Note cross bridging or blocking. Floor
/J~ists and rafters 12" or more in depth shall be
supported laterally by bridging at intervals not
exceeding 8 feet, unless both edges are held in
line. Sec. 2506 (g).
~. Show blocking at ends and at supports of
4ioor joists, and for rafters at exterior walls.
Section 2517 (d) 3.
9/. Show solid blocking at ridge line and at
faJC.terior walls on trussed roofs.
Section 2506 (g), Section 2517 (h).
190. Show double joists. Floor joists shall be
efoubled under bearing partitions running
parallel with the joists. Section 2517 (d) 5.
1,/1. Bearing partitions, perpendicular to
Joists, shall not be offset from supporting
girders, beams, walls or partitions, more than
the depth of the joist. Section 2517 (d) 5.
1112. Show rafter ties. Rafter ties shall be l~ed not more than 4 feet on center and be
just above the ceiling joists, where rafters and
ceiling joists are not parallel.
Section 2517 (h) 4.
10'3. Show rafter purlin braces to be not less Jian. 45 degrees to the horizontal.
Section 2517 (h) 5.
8
3/25/86
~) Show 1/211 minimum clearance between top
~te of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
r_" Show double top plate with minimum 4811
lap splice. Section 2517 (g) 2.
_zll6: Show nailing will be in compliance with
Table 25-Q.
@ Show or note fire stops at the following
/locations per Section 2516 (f):
a. in concealed spaces of stud walls and
partitions, including furred spaces,
at the ceiling and floor levels and at
10 foot intervals along the length of
the wall.
b. at all interconnections between
concealed vertical and horizontal
spaces such as occur at soffits, drop
ceilings and cove ceilings;
c. in concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and in
line with the run of stairs if the
walls under the stairs are unfinished;
and
d. in openings around vents, pipes,
ducts, chimneys, fireplaces and
similar openings which afford a
passage for fire at ceiling and floor
levels, with noncombustible
materials.
~ Show stud size and spacing. Maximum
allowable stud heights; Bearing wall: 2 x 4 and
2 x 6 max. 10'; Non-bearing: 2 x 4 max. 14', 2
x 6 max. 20 1 • Table 25-R-3.
f.. Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 1611 o.c.
Table 25-R-3.
Note an A.I.T.C. Certificate of Compliance
glued laminated wood members shall be given
to the building inspector prior to erection.
Section 306 (f).
ji. Detail all post to beam and post to
footing connections and reference the detail to
the plan. Section 2516 (m).
1~/ Detail shear transfer connections,
(n~~uding roof and floor diaphragms, to shear
walls. Section 2513.
,J3. Specify nail size and spacing for all
{;ear walls, floor and roof diaphragms.
Indicate required blocking. Maintain maximum
diaphragm dimension ratios. (Tables 25 I, J, K)
and Section 4713 (d).
1 /4. Show 311 x 411 or 211 x 611 studs in first
ft~ry of three story building. Table 25-R-3.
,./4. Provide truss details and truss
falculations for this project.
11/ Provide roof framing plan and floor
¥aming plan. Section 302 (a) 7, r. Provide framing sections through
Section 320 (a) 7.
1../.. Specify all header sizes for opening over
lo-wide. Section 2517 (g) 5.
11'-' Provide calculations for main vertical and
1'rizontal framing members and post footings.
Section 302 (a) 7.
~ Provide calculations for lateral loads,
/-;;;-ear panels, shear transfer and related.
Section 302 (9) 7.
• Show on the plans all structural
uirements developed in the structural
calculations.
.L. Colunms and posts located on concrete or
Conry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural
resistance to decay or treated wood is used.
Section 2516 (c) 4.
9(. Individual concrete or masonry piers shall
firoject at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4,
@. Show location of attic access with minimum
/ rize 2211 x 3011 • Section 3205.
,✓ Show draft separation for attic areas
re;~een units in a duplex. Section 2516 (f).
1?/ Wood stud bearing walls, with studs at 24" z~:, require 3 ea. 2 X 4 or 2 ea. 2 X 6 or 2
ea. 3 x 4 top plates if supporting either floor
members or roof trusses that are spaced more
than 1611 o.c. and do not bear within 511 of the
supporting stud. Section 2517 (g) 2.
3?.• Specify plywood grade and panel
identification index. Table 25-N.
~ When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
0-If foundation cripple wall studs are less
than 1411 framing shall be solid blocking.
Section 2517 {g) 4.
G.¼-,, 'l & ND Sr==c, B, $-rr:, c... ?
To
9
3/25/86
1-;,tf. Cripple wall studs exceeding 4 feet in
height shall be 3 inch by 4 inch or 2 inches by
6 inches when supporting 2 stories.
Section 2517 (g) 4.
µ1. Show plywood sheathing over exposed eaves,
or other weather exposed areas, is exterior
grade. Section 2516 (g) 3.
/z. Show a weep screed at the foW1dation plate
line on all exterior and stud walls to be
stuccoed. Section 4706 (e).
1 £ Show corridor width to be minimum 3611 •
le~~ion 3305 (b).
13Y, Specify truss
,{cess.
layout for 3011 x 3011 attic
J. Ridges, hips, and valleys shall be at
least one size larger than supported rafters.
Section 2517 (h) 3. fa· In open beam construction, provide strap
ties across the beams at the ridge support.
Section 2501 (b).
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code.
, .,/_ Show the size, location and type of all l~~ing and cooling appliances or systems.
ii. Show source of combustion air to furnace, re; Chapter 6, UMC.
, /a. Every dwelling unit shall be provided with
~ting facilities capable of maintaining a room
temperature of 70 degrees F. at 3 feet above the
floor in all habitable rooms. Show basis for
compliance. UBC, Section 1211.
10
3/25/86
y.6.
space
Show minimum 3011 deep unobstructed working
in front of furnace. Section 505, UMC.
~ Note on plans, clearances to be per
manufacturer Is listing. Section 504, UMC.
2:; Furnace shall not be installed under any
stairway. Section 704, UMC.
1 ,/ Furnace shall not be installed in any
~~~oom, bathroom or in a closet or confined
space with access only through such room, unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704, UMC.
yL. Show I.C.B.O. approval number for prefab
fireplace.
1WS: Show access to the f~e to be minimum 30
Section 708 & 709 UMC.
attic or underfloor
inches by 30 inches.
¥-Note that passageway to the attic furnace
shall be unobstructed and have continuous solid
flooring not less than 24 inches wide.
Section 708, UMC.
✓ Show permanent electrical outlet and
lighting fixture controlled by a switch for the
attic furnace. Section 708, UMC.
,,/Show details to comply with Section 709 'fu 0
f~e under the floor, or Section 710 for
roof or outside furnace.
Q. Note on plan: Gas vents and
foncombustible piping passing through three
floors or less shall be effectively draft
stopped at each floor or ceiling.
UBC, Section 1706 (a) 6.
K. IILECllICAL (IIAT.IORAL IILECllICAL OODI!)
All wiring shall comply with the National
Electrical Code.
~. Show on the plan the amperage of the
;sf'electrical service, the location of the service
panel and the location of any sub-panels.
_.®. Show location of ,J?l receptacles.
all electrical
_W). Electrical receptacle locations and/ or
/spacing is not adequate in 1?<:c.-+1 ND YOC>r"Z..
153. Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
Jr;;). Note onvenience outlets in !:'throoms,
/ o~tdoors, and in arages and basements ( other
than for laundry and similar equipment) shall be
GFI protected, NEC, Art. 210-8.
¥-Note electrical system ground to be
provided per NEC, Art. 250-81.
L. PLllllBillG (UNDOldl .PL1IIIIDC OODI!)
1 ~/ Show water heater size, type and location
Tn;1ans. UPC, Section 1310.
,a/ Show source for providing combustion air {o' ;uel burning water heater. If wall opening
in an enclosure are used, at least one-half of
the required opening area. shall extend into the
upper twelve inches of the enclosure and
one-half within the lower twelve inches.
UPC, Section 1307.
11
3/25/86
f{ Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom.
UPC, Section 1309.
;,/. Provide adequate barrier to protect water
heater from vehicle damage. UPC, Section 1310.
UPC,
Show T and P Valve on water heater and
route of discharge line to exterior.
Section 1007 (e).
Provide dryer vent to outside.
Section 1903 •
.@ Note on the plan that hose bibbs and lawn
_,,.?'sprinkler systems shall have approved backflow
prevention devices. UPC, Section 1003.
163. Shower stall shall acco1I1DOdate a 3011
circle and have a minimum floor area of
1,024 sq. in. UPC, 909 (d).
M. NDISI! msoI.AnOII (OOPLEXIS)
, ,.f Show details of duplex co111110n (party)
~;is and floor/ceiling assemblies to achieve a
Sound Transmission Class (STC) rating in walls
of 50 decibles and on Impact Insulation Class
(IIC} rating on floor/ceiling of 50 decibles.
Title 25.
Show how penetrations of assemblies for
mg, electrical devices, recessed cabinets,
bathtubs, soffits, or hes.ting ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required s0W1d
transmission rating. Title 25.
~ Provide insulation in walls and ceiling to
achieve STC of 50 between garage and living area
if garage use is not controlled by resident.
Title 25.
11. l!lll!RGx Wl'i!@rn\TIOII: PL1!AS1! WD
State regulations (California Admin, Code)
require that the design satisy one of the
attached alternative energy packages or submit
calculations. The law also requires that many
mandatory conservation items be satisfied.
• Show on the Title Sheet of the plans, the
uired elements of the alternative energy
package that was selected, and next to each
element show how you are complying with each
element. If calculations were used, provide
similar data on the plans,
A . The plan sheet showing the required
ements of the selected energy package, and
listing the design elements showing compliance
with that selected package, must be signed by
either the owner or a licensed professional
i.e., architect, engineer or contractor. A
design professional must note his/her-state
license number. Section 1403 of Title 20,
Q. Show on the plans the 11R11 value for the
~ls, floors, ceiling and related areas/ i::or.:z.
?~'ic:.A<..G' ~\:n..\,:' c.."'1"1EO '
170. Show double glazing as per Energy Design,
on Glazing Schedule.
y{.. Show on the plan how shading requirements
are satisfied,
1
~-172, The plans are not in compliance with the ~1/ energy conservation compliance package selected
or design calculations provided. Show on plans
conformance as follows:
12
3/25/86
__ii). Specify on the building plans all of the
/~~atory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements".
Q. Show the size, type, make, model and
,,,.:t'i~;;ation of the space heating (or cooling)
system and provide heat lqss calQJl'i_tions if the
etJ:ut B_!U/Hr,;_ exce~ds !2~ ~--·
o. CARLSBAD S.P .D. & DllPLJX SllPPLIIIOO
y!, Energy
Zone _...,_7 __
conservation design should be for
See attached energy packages.
/ J-76. Floor drains must have auto-prime
( city policy).
@. Note exhaust fans cannot be ductless type
/ (city policy).
• New residential units must be pre-plumbed
future solar water heating. Note "two roof
jacks must be installed" where the water heater
is in the one story garage and directly below
the most south facing roof
(City Ordinance No. 8093).
r_" Note "two 3/ 411 copper pipes must be
installed to the most convenient future solar
panel location when the water heater is not in a
one story garage and is not directly below the
most south facing roof.
(City Ordinance No, 8093).
J60· All piping for present or future solar
water heating must be insulated when in areas
that are not heated or cooled by mechanical
means (city policy),
#-Incorporate the waterproofing details, on
the attached Policy so~a, where interior living
space occurs below grade at the masonry
wall(s).
•
@. Show on the Title Sheet on the plans, the
/ ~ormation required by the attached
Developmental Services Sheet ~ 1 \ ~ '2,93
,/.. All new residential buildings, including
/~;itions, require a soils report. Please
submit two copies.
, L. Heavy timber framing, minimum 611 x 1011 ~ and minimum 811 x 811 post, for the
structural beam and column supporting the fire
separation between the garage and living area
above, is acceptable if shown on the plans.
(city policy).
"B<e""1....:>w ,
185. Please see additional corrections~
:remarks, on tha foJJ ou;liAQ page
The City of carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123;
telephone number of 619/560-1468, to perfom the
plan check for your project. If you have any
questions regarding these plan check items,
please contact~--------------
at Esgil Corporation. If you have any questions
regarding City Building pemit procedures,
please contact Carter Darnell at the City of
carlsbad, 1200 Elm Avenue,
telephone 619/438-5525.
Thank you.
Enclosures:
3. \12.'3S3
13
3/25/86
' '
CITY OF CARLSBAD
Prepared by, □ Bldg, Dept,
-✓;w1 VALUATION AND PLAN CHECK FEE □ Esgil
PLAN CHECK NO, g{p-"2,'2,'7-I:
BUILDING ADDRESS .....;Z;...::3;..04-__,__-_0;...::(c,_L_E_::::.,__J_·,-.,--'-..;..N_:n::..;=cc_~_'"'T ________ _
APPLICANT/CONTACT _N~E?~r..;...J..;..~~D"'-----
BUILDING OCCUPANCY _.,l.1'2;;_·""-3.,.., ..:..M.:..:... __
TYPE OF CONSTRUCTION V-'N.
PHONE NO, "1 Z-'1 S' Do 1
DESIGNER PHONE. __ " ___ _
CONTRACTOR PHONE. ____ _
BUILDING PORTION BUILDING AREA VALUATION VALUE
MULTIPLIER
'"SA.'l91...= -JA>F<-i ',7\~
l\V\'I\J!-2 'J.., 2~ -(12... ) 5B,oo = ~(;,C.,,4 ?,0$?'~ -
I . ······ .L--: ---"
(:;?f,;R.. ~'I-v~ @., ) t4,oo ~ I~. ,_.,(p /5, Ob
• 1,,1!':..:.~ ... --•-•"•r•I·"
. . -
>::1~
~
--L::e-v ... '.-Ft ~ nc-f_ I ) I• \..(\.}-fL._ ,r~
~
(
Air Conditionin~
Commercial @
Residential ta
Res. or Comm.
Fire S'Orinklers @
~ 2 4.i_ 4-00 Total Value
.? --
Fee Adjusted To Reflect 0 Energy Regulations (fee x l,l)
✓.,,,-✓,
0 Handicapped Regulations (Fee x l.065) ·
B uildlng Perm it fee $ _ _._-,...=O:..;0;:....;,2,::_ _____ --'--------"--------
p lan check F ••__;S!,._ ___ Cc=:S::.~...:5=-• ..:'2::..o.:_ __________ _,$,.._ _____ _
COMMENTS,,_• ___________________________ _
8/4/82
r
I
1
'
,.
l'
PLAN CHECK t«>. 8(,,-ZZ~OOREssZJ a¥z 3:# Letbc L ef'oATE ~
PLAINING
ZONE1 ~k:
SCHOOL DISTRICT: CARLS~ SAN MARCos.JJL
SETBACKS! f'RONT ... d--10=----4 REAR _eJ_JC ___ _
DISCRETIONARY ACTIONS: . ...;~...._)1.1:A:=---....... -----------------
-REDEVELOPMENT PERMIT REQ~RED:,_.,t,~JAc::::...-i-------..J-
1
_________ _
:::r a. w
01: LANDSCAPE PLAN CCM4ENTS:,-----f}L!f.1.A=----------------------~ -,i--,~,91--..,,.
-'<-ILL-
~ ~ l ~ l ENVIRONMENTAL REQUIRED: . .f~.....,./.._( _________ ,. ___________ _
01: a, o:: > B
0 a, " U 01: C
/
ENGINEERING
LEGAL DESCRIPTION VERIF'IED? -:fjw APN CHECKED? . .....;.1f==;;-,:::;.-=:..-------
P.f'.F.: N/Rr PARK-IN-LIEU QUADRANT:~, FEE PER UNIT: .
RIGHT-Of-WAY: ~ . TRAFFIC IMPACT FEE PER UNIT:J;5'3" < (10 7 .,_, \
~
-m
EASEMENTS: 1YmA,, ~ 1
DRIV~WAY:~~66~ ~
1MPRovEHENTs: F✓ ~ emJ.r, ~ a...& ~.eJo(fiJk
01:
:::> --t-
0 w __
01:
OK TO ISS~~--? 1
DPD2:DPD6:04/15/86
DATE:__,'S~~-2...,/,~A'--~-----
ENCINITAS UNION SCHOOL DISTRICT
189 Union Street
Encinitas, CA 92024
Telephone: (619)753-1152
Dedication of land or Fees for School Districts
(Title 8, Division 2, County Code)
TO: '!he City of carlsbad
1200 Elm Avenue carlsbad, CA 92008
Plan Check No.
Effective =oa-te=---=p,...a.l."'"0 d..--:P""lan--,Check..---.---::Fee:---
* * * * * * * * * * * * * * * * * * * * * * * * • * * * * • * * * *
PROPERTY OWNER'S NAME Cligoric Construction Co. (Daniel Blazic) -------------------------
TELEPHONE/'29-5001 ADDREssP.O. Box 6248, Oceanside, CA 92056
PROJECT NAME (if applicable) ---------------------
PROJECT LOCATION ---------------------------
ASSESSOR'S PARCEL NO. 216-240-21
TOTAL NUMBER OF DWELLING UNITS 1 duplex (6 bedrooms)
Applicant·~---~ Title
* * * * • * • • * * * * * * * * * * * * * * * * • * * * * * * * * * *
School District Certification
6 No. bedroans/like roans -----
I certify that the :cequirenents of Title 8, Division 2 of the
County Code for school facilities dedication of land or fees
have been satisfied for the above described project.
¼{;& ~~it~~/ Donald E. Lindstrom, Superintendent
Signature of School Official ,__ Ti
June 23 1986
Date
* * * * * * • * * * * * * * * * * * * * * * * * * * * * • * * * * * •
NOTE TO ) A review of one set of plans is
APPI,;J;CANT) required by the school district.
FOfM 00. 01-021 Dl1trllll,tlo11:
W1'Ue• Appl lt111t ,,now; OhtrlU
"•• ~ A,pl lu11t