Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2310 CAMINO VIDA ROBLE; ; CB023120; Permit
03-07-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB023120 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2310 CAMINO VIDA ROBLE CBAD Tl Sub Type: COMM 2130500800 Lot#: 0 $986,880.00 Construction Type: NEW Reference #: SEASILVER USA Tl 28,532 SF OFFICE TO OFFICE Tl Applicant: HOWARD ANDERSON 2194 CARMEL VALLEY RD 92014 858-755-5009 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: ISSUED 10/16/2002 SB 11/19/2002 11/27/2002 PD Owner: ON1MAC CORP 12520 HIGH BLUFF DR #100 SAN DIEGO CA 92130 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $3,049.63 Meter Size $0.00 Add't Reel. Water Con. Fee $1,982.26 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $207.24 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $1,524.82 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $216.00 $310.00 $205.50 $0.00 $0.00 $0.00 $0.00 $7,495.45 Total Fees:$7,495.45 Total Payments To Date:$7,495.45 Balance Due:$0.00 BUILDIN4S PLANS ACHED Inspector: FINAL APPROVAL Date: 3~~fi Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 11-27-2002 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB023120 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2310 CAMINO VIDA ROBLE CBAD Tl Sub Type: 2130500800 Lot#: $986,880.00 Construction Type: Reference #: SEASILVER USA Tl 32,896 SF OFFICE TO OFFICE Tl COMM 0 NEW Applicant: HOWARD ANDERSON 2194 CARMEL VALLEY RD 92014 858-755-5009 Owner: ONIMAC CORP Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 10/16/2002 SB 11/19/2002 11/27/2002 2331 12/02/02 0002 01 02 CGP 3988-37 Total Fees: $5,970.63 Total Payments To Date: $1,982.26 Balance Due: $3,988.37 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add1! Pot. Water Con. Fee Reel. Water Con. Fee $3,049.63 Meter Size $0.00 Add't Reel. Water Con. Fee $1,982.26 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $207.24 PFF $0.00 PFF (CFD Fund) $0.00 License Tax $0.00 License Tax (CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.001 $0.00 $216.00 $310.00 $205.50 $0.00 $0.00 $0.00 $0.00 .9] MAS EXPIRED IN ACCORDANCE WITH U&C, SECTION 106.4.4 SlftMATURP • Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legai action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or sendee fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to wfaiebJhe statute of limitations has previously otherwise expired. PERMIT APPLICATION \ it CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated By n«te Address (include BIdg/Suite *)Busim Legs! Description Lot No.Subdivision Name/Number Assessor's Parcel *Existing Use Description of Work SQ.FT. Name Addrasi Name Address Nsme Address (Sec. 7031.6 Business snd Professions Cods: Any City or County which requires e permit to construct, alter, improve, demoUsn o, .^^ \ ~v*""' irior to its Issusnce, also requires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractors iwsnse Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he Is exempt therefrom, and the bssty for the alleged exemfitfcn\ Anv violation of Section 7031.6 bv any applicant for a permit subjects the applicant to a civil, ~ ~ Name Address Ststs Lloenss * & "•SsP^fi*-^ Ucsnse Class City State/Zip Telephone f City Business License * /THr £~J <£*O Designer Name Address State License * City Stste/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have end will maintain a certificate of consent to self-insure for workers' compensation ss provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. Q I have and will maintain workers' compensation, ss required by Section 3700 of the Labor Coda, for the performance of the work for which this permit to issued. My worker's compensation Insurance carrier and poJIcx number are: ffju.t f\ r\ r> "i Insurance Company ^TYVT-ft. C-Q-rTN.r PokcvNe. W»f ~OO I 0 ' T/ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100] OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which tills permit is issued, I shaH not employ any person In any manner so aa to become subject to the Workers' Compensation Lews of California. WARNING: Failure to eorfra wortwe^-eompeneation^ewejaiie Is unlawful, and anal subject an employer to criminal penaMee snd cM fines up to one hundred thousand dotes (tlOBjHl)* In eddWofttojM*cqsrofort^ensation, damages as provided for In Section 3706 of the Labor code. Interest and attorney's fees. SIGNATURED ^X^^^^^^^t^-^ DATE I hereby affirm that I em exempt from the Contractor's UcenWtlw for the following reason: D I, ae owner of the property or my employees with wegea aa their sols compensation, will do the work and the structure la not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does net apply te an owner of property who fauHds or Improves thereon, and who does such work himself or through his own employees, provided thet such Improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one veer of completion, the owner-builder will have the burden of proving that he did not buHd or Improve for the purpose of sate). Q I, as owner of the property, em exclusively contracting with licensed contractors to construct the protect (Sec. 7044, Business end Professions Cods: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, end contracts for such projects with contractoris) licensed pursuant to the Contractor's Ucsnse Lew). D I am exempt under Section Business snd Professions Cods for tills reason: 1. I personally pten to provide the major labor and materiels for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed en application for s building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to ooonfnate, supervise and provide the major work (Include name / address / phone number / contractors license number!: 6. I will provide some of the work, but I have contracted (hired) the following persons to provide the work Indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit s business plan, acutely hazardous mstsrials registration form or risk management and prevention program under Sections 25605, 25533 or 28B34 of the Preslsy-Tsnner Hazardous Substance Account Act? Q YES O NO Is the sppKcant or future building occupant required to obtain e permit from the air pollution control district or air quality management district? Q YES Q NO to the fecillty to be constructed within 1,000 feet of the outer boundary of a school sits? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) CM! Coda). LENDER'S NAME LENDER'S ADDRESS I certify thst I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with aH Oty ordinance! and State laws relating te building construction. I hereby authorize representatives of the Cit» of Carlsbad to snter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 6'0" deep and demolition or construction of structures over 3 stories In height. EXPIRATION: Every permit Issued by the building Official under the provisions of this Code shall expire by limitation and become null and vokJ If the bulking or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permft Is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE; File YELLOW: Applicant PINK: Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated Date Business Name (at this address)Address {include Bldg/Suite #) Legal Description Lot No.Subdivision Neme/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use Description of Work SO. FT.#of Stories # of Bedrooms # of Bathrooms Name Address City State/Zip Telephone # X Name Address City State/Zip Telephone # (Sec. 7031.5 Business end Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its lance, also requires the applicant for such permit to file a signed statemerpVthiK^he is licensed pursuant to the provisionsjjf the Contractor's License Law [ChVpter 9, commending with Seaflbn TOQO of Division 3 of the Business ejra Professions Code] or that he is exempt thera^romVand the basis for the alleged exemption. Any violation of Secjwn 7031 .sSy any aqplican^for a j>ejmit sujqects the appltagoLio a civil penalty of not moreahan flv\hundred dollars [4500]). Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number ere: Insurance Company Policy No. Expiration Date SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) ERT1FICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as ome subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shad subject an employer to criminal penalties and civil fines up to one hundred thousand dollar* ($10^,000), IrnuMrtionito tlA cost of compensation, damages as provided for hi Section 3706 of the Labor code, (Qteresjand attorney's fees. SIGNATL id dollar* <$10£000), ruse T^/ >y- I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sele (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to en owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License tew). O I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not} signed an application for a building permit for the proposed work. 3. I have contracted with the following person {firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): ____ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 26505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES (tf NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1 ,OOO feet of the outer boundary of a school site? O YES Qd NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. *} „, , „„»„„„„, u, I hereby affirm that there is e construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i> Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with alt City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void If the building or work authorized by such permit i i nnmunmenenri within 1 nn rlmn fr[^m thr rijin nL^'r"""" -" " th-° K- -'i-ilng T work authorized by such permit is suspended or abandoned at any time after the wogris"cofpifie[5ed InMyjenhrtJifil IBM ilijys (Sepyi)iJO^A4~britfoffl^.Building Code). APPLICANT'S SIGN DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Building Department To Whom It May Concern: RE: 2310 Camino Vida Roble March 14,2006 On Monday March 13,2006 the City finaled Building Permit number CB02-3120 for construction at 2310 Camino Vide Roble. This permit does not allow any occupancy at this location but does complete the inspection process of some work started several years ago. This also will allow us to close the Code Enforcement case at this address and to remove the "Notice Of Non Compliance" we have filed for this location. If you have any questions I can be reached @ 760 602-2721. ;e Peterson Carlsbad Building Department 1635 Faraday Avenue • Carlsbad, CA 92OO8-7314 • (76O) 6O2-2700 Building Counter • (76O) 6O2-2719 • FAX (76O) 602-8558 Inspection List Permit**: CB023120 Type: Tl Date Inspection Item 03/13/2006 89 03/13/2006 89 03/09/2006 14 03/09/2006 24 03/09/2006 34 03/09/2006 44 03/09/2006 84 04/08/2003 84 04/08/2003 89 04/01/2003 89 03/31/2003 14 03/31/2003 44 03/27/2003 84 03/25/2003 84 03/21/2003 89 03/19/2003 89 03/18/2003 89 03/14/2003 84 03/14/2003 89 03/12/2003 34 03/07/2003 24 03/07/2003 34 03/07/2003 44 02/26/2003 17 02/25/2003 17 02/21/2003 17 02/19/2003 17 02/19/2003 24 02/19/2003 34 02/11/2003 21 02/05/2003 14 02/05/2003 17 02/05/2003 24 02/05/2003 34 02/04/2003 17 01/31/2003 17 01/29/2003 24 01/28/2003 14 01/28/2003 24 01/28/2003 34 01/08/2003 34 01/07/2003 14 01/07/2003 24 Final Combo Final Combo Frame/Steel/Bolting/Weld in Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo Rough Combo Final Combo Final Combo Frame/Steel/Bolting/Weldin Rough/Ducts/Dampers Rough Combo Rough Combo Final Combo Final Combo Final Combo Rough Combo Final Combo Rough Electric Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Rough/Topout Rough Electric Underground/Under Floor F rame/Steel/Bolting/Weld in Interior Lath/Drywall Rough/Topout Rough Electric Interior Lath/Drywall Interior Lath/Drywall Rough/Topout Fra me/Steel/Bo Itin g/Weldin Rough/Topout Rough Electric Rough Electric F rame/Stee l/Bolti ng/Weld i n Rough/Topout COMM Inspector Act PD - PD PD PD PD - PD PD PD PD PD PD PD PD PD PD PD PD PD PS PS PS RB RB PD PD PD PD PS PD PD PD PD PD PD PD PD PD PD PD PD PD AP Rl AP we we we Rl AP NR PA PA PA CO CO we CO CO CO CO CO CA CA CA AP NR AP PA PA PA AP PA PA PA PA PA PA AP PA PA PA NS NR PA SEASILVER USA Tl 28,532 SF OFFICE TO OFFICE Tl Comments CEILING OK TO OCCUPY OFFICE BY OPEN OFFICE CEILING SAME AS 3/25/03 PERIMETER WIRES OK TO OCCUPY OPEN OFFICE CEILING IN RSTRMS - NO PERMIT TO SIGN IN RSTRMS COMPLETE EXCEPT BATH SEWER TIE IN PLANS NEED TO BE REVISED Tuesday. March 14, 2006 Page 1 of 2 01/07/2003 34 Ro^gh Electric PD NR NEED REVISED PLANS - CALLED CONTRACTOR 12/27/2002 21 Underground/Under Floor PD AP 12/27/2002 24 RoughHopout PD WC Tuesday, March 14, 2006 Page 2 of 2 City of Carlsbad Bldg Inspection Request For: 03/13/2006 Permit# CB023120 Title: SEASILVER USA Tl 28,532 SF Description: OFFICE TO OFFICE Tl Inspector Assignment: PD 2310 CAMINO VIDA ROBLE Lot 0 Type: Tl Job Address: Suite: Location: APPLICANT HOWARD ANDERSON Owner: Remarks: Sub Type: COMM Phone: 619 Inspe Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: GILBERT CHAVEZ Entered By: KAREN Act. Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# CV040246 CLOSED H-EXP BLDG PERMIT CB023120; CV040760 CLOSED N- EXCESSIVE JUNK & DEBRIS; PCR03015 ISSUED SEA SILVER; REVISE OFFICE LAYOUT Inspection History Date Description Act Insp 03/09/2006 14 Frame/Steel/Bolting/Welding AP PD 03/09/2006 24 Rough/Topout WC PD 03/09/2006 34 Rough Electric WC PD 03/09/2006 44 Rough/Ducts/Dampers WC PD 04/08/2003 84 Rough Combo AP PD 04/08/2003 89 Final Combo NR PD 04/01/2003 89 Final Combo PA PD 03/31/2003 14 Frame/Steel/Bolting/Welding PA PD 03/31/2003 44 Rough/Ducts/Dampers PA PD 03/27/2003 84 Rough Combo CO PD 03/25/2003 84 Rough Combo CO PD Comments CEILING OK TO OCCUPY OFFICE BY OPEN OFFICE CEILING SAME AS 3/25/03 PERIMETER WIRES City of Carlsbad Bldg Inspection Request For: 01/07/2003 Permit# CB023120 Title: SEASILVER USA Tl 32,896 SF Description: OFFICE TO OFFICE Tl Inspector Assignment: PD 2310 CAMINO VIDAROBLE Lot 0 Type: Tl Job Address: Suite: Location: APPLICANT HOWARD ANDERSON Owner: Remarks: Total Time: Sub Type: COMM CD Description 24 Rough/Topout 34. Rough Electric Act Commentft Phone: 7602687000 X11103 Inspector, Requested By: N/A Entered By: ROBIN go Associated PCRs/CVs inspection History Date Description Act Insp Comments 12/27/2002 21 Underground/Under Floor AP PD 12/27/2002 24 Rough/Topout WC PD Q AR^UCANT a PLAN REVIEWER Q FILE EsGil Corporation In Partnership with Government for Building Safety DATE: 11/14/02 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-312O SET: III PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT NAME: Seasilver TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [~~! The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Contractor. Telephone #: In Person Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Esgil Corporation D GA D MB D EJ D PC Enclosures: Walk In tmsmtl.dot Carlsbad 02-3120 11/13/02 EsGil Corporation In Partnership with Government for Building Safety DATE: 11/13/02 Q APPLICANT JURISDICTION: Carlsbad Q FILE PLAN CHECK NO.: 02-3120 SET: II PROJECT ADDRESS: 231O Camino Vida Roble PROJECT NAME: Seasilver TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Howard Anderson Assoc. 2194 Carmel Valley Road, Del Mar, CA 92014 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Howard Anderson Assoc. Telephone #: (858) 755-5009 Date contacted: 11 / /3/ox (by:^*) Fax #: (858) 755-1236 Mail -Telephone Fax^ In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 11/4/02 trnsmtldot Carlsbad 02-3120 11/13/02 NOTE: The items listed below refer to the item numbers from the previous list. These remaining items have not been adequately addressed. The notes in bold at the end of each item are to emphasize the remaining problem. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 4. Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Show in this analysis the occupant ioad of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths. It is not entirely clear where the proposed exit path is for the various areas within the Tl. THE EXIT PLAN ON SHEET MOE-1 SHOWS THAT TWO EXITS ARER REQUIRED FROM ROOM 102. ONE OF THESE EXITS MAY BE INTO A NON RATED HALLWAY. HOWEVER, THE 2ND EXIT MUST BE TO THE EXTERIOR OR INTO A FIRE RATED CORRIDOR. ENERGY CONSERVATION 8. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131 (d). NO RESPONSE TO THIS ITEM AND NOTHIN SHOWN ON THE PLANS. 9. Detail required exterior lighting controls. "Exterior lighting controlled from a lighting panel within the building shall be controlled by a directional photocell or astronomical time switch that automatically turns off exterior lighting when daylight is available." NO RESPONSE AND NOTHIN SHWON ON THE PLANS. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In Partnership with Government for Building Safety DATE: 10/25/O2 Q 'URIS? JURISDICTION: Carlsbad a^PLANREVIEWER a FILE PLAN CHECK NO.: 02-312O SET: I PROJECT ADDRESS: 231O Camino Vida Roble PROJECT NAME: Seasilver TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Howard Anderson Assoc. 2194 Carmel Valley Road, Del Mar, CA 92014 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Howard Anderson Assoc. Telephone #: (858) 755-5009 Datecontacted:iofo5/o*- (by:j^- ) Fax #: (858)755-1236 Ma II .^Telephone Fax*X In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA • MB D EJ D PC 10/17/02 tmsmH.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 Carlsbad 02-3120 10/25/O2 ' PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 02-312O OCCUPANCY: B, Fl, SI TYPE OF CONSTRUCTION: III N ALLOW ABLE FLOOR AREA: Unlimited SPRINKLERS?: yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 1O/25/02 JURISDICTION: Carlsbad USE: Office, Mfg &Sstorage ACTUAL AREA: 40,566 STORIES: one HEIGHT: No Change OCCUPANT LOAD: 298 DATE PLANS RECEIVED BY ESGiL CORPORATION: 10/17/02 PLAN REVIEWER: Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list for a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot Carlsbad 02-3120 10/25/62 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a note on the plans indicating whether or not any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. 2. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6. 3. Include on the reflected ceiling plan the location of the draft stops above the suspended ceiling. See details M & N/TI-7. in buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 708. 4. Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Show in this analysis the occupant load of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths. It is not entirely clear where the proposed exit path is for the various areas within the Tl. 5. The hallway surrounding the open office area '130* is considered an adjacent room for exiting. Since this hallway is used as an exit for rooms127 & 129 both of which have more than 10 occupants, the exits from the hallway must lead directly outside or must lead to a fire rated corridor or exit passageway. UBC 1004.2.2. exception 3 (NOTE a hallway is considered an intervening room). Carlsbad 02-3120 10/25/02 6. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies, you may note "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed at the main exit. Section 1003.3.1.8. 7. When more than one exit is required, the exit access shall be arranged such that there are no dead ends in hallways more than 20' in length. Section 1004.2.6. The hallway leading to door D57, D69 & D28 are dead end hallways that are not allowed. DEPARTMENT OF STATE ARCHITECT TITLE 24 DISABLED ACCESS REQUIREMENTS 8. Rest room stall doors D62 and D34 must swing out. The plans show the doors swinging into the stall. 1115B.7.1.5. • ELECTRICAL PLAN REVIEW • 1996 NEC • PLAN REVIEWER: Morteza Beheshti 1. Provide a minimum of 1 foot-candle of emergency illumination at the storage floor level. UBC 1003.2.9.2 & NEC 700-16. 2. Provide a disconnect for each sign. NEC 600-6. 3. Please change all references the NEC code cycle date to 1996. 4. Please specify the required room power disconnecting means for the server room if it is an "information technology equipment room". NEC 645-2. Note: If you have any questions regarding this electrical plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. • PLUMBING (1997 UNIFORM PLUMBING CODE) 1. The combined vent area for isometric plan I & IV may not be less than the main drain line. The 2 1-1/2" vents shown on sheet P.2 are undersized. 2. Show on the plans the location of clean outs every 100 ft of drain line. MECHANICAL (1997 UNIFORM MECHANICAL CODE) 3. Detail required roof access ladder to roof mounted HVAC equipment. UMC, Section 307.5. Carlsbad O2-3120 10/25/02 4. Detail disposal sites of main condensate drainage from air conditioning units. UMC Section 309. 5. Detail on the plans the condensate drain line sizes and the trap and vent at each of the HVAC units. ENERGY CONSERVATION 6. Provide complete energy designs for the proposed new conditioned building envelope, Provide the completed ENV-1, ENV-2, ENV-3, forms showing energy compliance. The ENV forms must be signed and imprinted on the plans. 7. Show on the plans the required roof and wall insulation as required by the energy design. 8. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 9. Detail required exterior lighting controls. "Exterior lighting controlled from a lighting panel within the building shall be controlled by a directional photocell or astronomical time switch that automatically turns off exterior lighting when daylight is available." To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 02-3120 10/25/02 * VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 02-3120 PREPARED BY: Chuck Mendenhall DATE: 10/25/02 BUILDING ADDRESS: 231O Camino Vida Roble BUILDING OCCUPANCY: B, Fl, SI TYPE OF CONSTRUCTION: III N BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft) 40566 cb Bldo. Permit Fee bv Ordinance w Valuation Multiplier City Est By Ordinance Reg. Mod. VALUE ($) 986,880 986,880 $3,049.63 Plan Check Fee by Ordinance Type of Review: C3 Repetitive FeeRepeats Complete Review D Other •- Hourly Structural Only Hour* Esgll Plan Review Fee $1,982.26 $1,707.79 Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE - 2^- oz ADDRESS KESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR « $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE DoesJMlsformsff'lannlng Engineering Approvals Carlsbad Fire Department 023120 1635 Faraday Ave. Carlsbad, CA 92008 '• Plan Review Requirements Category: Date of Report: n/05/2002 Fire Prevention (760) 602-4660 Building Plan Reviewed by; Name: Address: City, State: Howard Anderson 2194 Carmel Valley Rd Del Mar CA 92014 Plan Checker: Job Name: Seasitver USA Job Address: 2310 Camino Vida Roble job#: 023120 BldQ #: CB023120 Ste. or Bldg. No. Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job # 1st 2nd 3rrl 023120 FDFile* Othpr Arjpnny in Carlsbad Fire Department 023120 1635 Faraday Ave. Carlsbad, CA 92&08 -, Plan Review Requirements Category: Date of Report: 10/29/2002 Fire Prevention (760) 602-4660 Building Plan Reviewed by: Name: Address: Howard Anderson 2194 Carmel Valley Rd City, State: Del Mar CA 92014 Plan Checker: Job Name: Seasiiver USA job#: 023120 Job Address: 2310 Camino Vida Roble Bldg #: CB023120 Ste. or Bldg. No. r-1 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job # 1 fit gnri SIT! 023120 FDFile* Othpr Anflnny ID Requirements Category: Building Plan Requirement: Pending 05.32 Additional Requirements or Comments i i Provide information on what is proposed in all storage areas and mailroom/storage area. Pagel 10/29/02 TITLE 24 REPORT Title 24 Report for: SEASILVER 2310 CAMINOVIDAROBLE CARLSBAD, CA 92009 Project Designer- Report Prepared By: HADI MAHZARI ENERGY CONSULTING GROUP 8015 BALBOA AVENUE SAN DIEGO, CA 92111 (858) 268-0660 Job Number: Date: 10/14/02 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards, This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number; FEATURES LiteKeeper is a compact self-contained lighting controller providing flexible time schedule control and override for eight circuits of light- ing. LiteKeeper's relays are rated to directly switch 20-amp lighting loads eliminating the need for external contactors or relays. Low voltage override switches may be assigned to relays through the program. • Integral seven-day time clock • Warn-before-off feature • Astronomic and auto DST functions • Holiday schedules • NEMA 1 enclosure with locking door • Eight 20-amp single pole relays • LCD display with English prompts • Assignable switch timers • Eight low voltage switch inputs • ON/AUTO/OFF override switch • Multi-tap 120/277 VAC operation • ETL, ETLC listed Catalog Number Type Circuit Switching System RCLK Lighting Control Panel \ LiteKeeper' ORDERING INFORMATION RCLK "'••120/277 Example: RCLK 120/277 Vbltage 120/277 Accessories Order as separate item RC PC IN Switching photocell for indoor applications RC PC 0 Switching photocell for outdoor applications LVS15011W C2 Single gang override switch, white* • Other finishes available, see sheet LCP-520 for details. L/THO/V/A L/GHT/NG LIGHTING CONTROL SYSTEMS LK-100 RCLK Lighting Control Panel, LiteKeeper SPECIFICATIONS HOUSING • Surface mount, NEMA 1. • 18-gauge CRS with hinged locking door. • Separate line and low voltage compartments. OPERATING VOLTAGE • 120/277 50-60Hz multi-tap power supply. RELAYS • Eight SPST with normally open (default), enclosed silver alloy contacts 20A @ 277 VAC. • Expected life: mechanical operations =1 x 107 electrical operations =1 x 105 PROGRAMMER • Built-in alphanumeric keypad. OVERRIDES • Eight low voltage class 2 switch inputs (momentary three wire, momentary two wire or maintained contact), assignable to relays through programming, adjustable time-out value per switch input (1-999 minutes), time-out to scheduled state. • Direct relay override from keypad. • Master ON/AUTO/OFF override switch. SCHEDULES • Eight operating schedules: -seven daily schedules -one holiday schedule • 64 event times can be distributed among the eight operating schedules. • One to eight relays can be controlled al each event time for a maximum of 512 event operations. • 32 definable holiday dates. • Auto daylight savings time adjustments with disable. • Astronomic operation with sunrise/sunset offsets. WARN OFF • One-second flash with 1-99 minutes delay before off. Operates per relay with schedules and switch overrides. BACKUP • Rechargeable capacitor, seven-day hold over for clock and memory. DISPLAYS • Two lines, 32 characters, LCD with English prompts, eight LED relay status indicators. DIMENSIONS All dimensions are in inches (millimeters). 14 (356) 14.5 (368) 9.5(241) door 9(229) enclosure WIRING DIAGRAM Override switches Switching photocell input Line Load LiteKeeper power LK-100 LK-1DO.PM5 ©1995 Lithonia Lighting 10/95 L/THOMA L/GHT/NG LIGHTING CONTROL SYSTEMS ONE LITHONIA WAV. DECATUR. GEORGIA 30035, TELEPHONE 770 967-4200, FAX 770 987-1002 IN CANADA: 1100 50TH AVE., LACHINE. QUEBEC H8T 2V3, DIVISION OF N.S.I. HOLDINGS. INC. L/THGN/A L/GHr/NG FEATURES Lithonia WPM wall plates provide a durable and attractive solution for configuring low voltage control switch assemblies. Wallpiates are offered in a variety of sizes and configurations and are punched to accept snap-in LVMS low voltage momentary switches. • Stainless steel construction • Natural or painted finishes • Clean, low-profile appearance • Available one to 10 gangs • One or two switch openings per gang • Accepts a variety of switch options Catalog Number Notes Type System Accessories WPM Wallplate for Low Voltage Momentary Switches SYNERGY ORDERING INFORMATION Example: WPM1G 1MSBS WPM WPM G Ho 10 Finish Options _MS 1to20 momentary switches' BS Brushed stainless WH Painted white IV Painted ivory LE Engraved faceplate1 Accessories Order as separate item. SQRS RE Recessed locking enclosure for one gang plate MXCS RE8 Recessed locking enclosure for two gang plates SQCS RE8 Recessed locking enclosure for five gang platas SQCS RE16 Recessed locking enclosure for eight gang plates MSA CLC 6 Surface locking enclosure; clear Lexan for one or two gang plates MSA CLC 8 Surface locking enclosure; clear Laxan for three gang plates LVMS Momentary Switch (see sheet ISA 2000 for details) NOTES: 1 Must equal the number of gangs (one switch per gang) or two times the number of gangs (two switches per gang). 2 Two linss, seven characters per line foi two switches per gang plate or two lines, 12 characters per line for one switch per gang plate. Controls Sheet #: WPM2 LK-130 WPM Wallplates for Low Voltage Momentary Switches SPECIFICATIONS CONSTRUCTION • Faceplates are formed from #430 stainless steel, .032" thickness. INSTALLATION • Switches (ordered separately) snap into faceplate openings. • Faceplate attaches to standard switch box with screws provided. CONFIGURATIONS DQ WPM1GZMS_ DDDDDDDDDD WPM 5G 10MS DQQDDDDDDaDD WPM 6G 12MB DDDDDDDDDDDDnD WPM 7G 14MS DDQQQDQaDDaDDQDQ WPMBG 16MS DDDnDDDDDDDaDDDDDD WPM 9G 1 SMS D WPM 1G IMS WPM 2G 4MS LE WPM 4G *MS D D D D D WPM SG 6 MS D D D D D D n D a D D [1 D DDDDDDDD DDDDDQDDD WPM 9G 9 MS DDDDDDDDaanDDDDDDDDD DDDDnDDDDD DIMENSIONS All dimensions are inches (millimeters). No. of Gangs Width , Width 1 2.75 (69.9) P 2 4.56(115.8) 3 6.38(162.1) 4 8.18(207.8) 5 10.00(254) 6 11.81(300) 7 13.63(346.2) 8 15.44(392.2) 9 17.25(438.15) 10 19.06(484.13) WPM 2<3 2MS UE 3.28 4.50 (83.3) (114.3) WPM 10G 20MS WPM 10G 10MS L/THOMA L/GHT/NG An*5AcultyBrands Company Sheet #: WPM2 wpm2.p65 ©1997 Acuity Lighting Group, Inc., Rev. 07/02 Lithonia Lighting Acuity Lighting Group, Inc. Lighting Controls Systems One Lithonia Way, Decatur, GA 30035 Phone:800-533-2719 In Canada: 1100 50th Ave., La chine, Quebec HBT 2V3 www.lithonia.com 58^ Q3 _ iu a: o*-0 <S^C-5 swy ..o ^ iJ- •ft3 HI LL _ So w O i- _j & 02-18-2003 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No: PCR03015 Building Inspection Request Line (760) 602-2725 Job Address: 2310 CAMINO VIDA ROBLE CBAD Permit Type: PCR Parcel No: 2130500800 Lot#: Valuation: $0.00 Construction Type: Reference #: CB02-3120 Project Title: SEA SILVER REVISE OFFICE LAYOUT 0 NEW Applicant: WATERS CONSTRUCTION 4755 FRAZEE RD 92057 619454-3472 Status: ISSUED Applied: 01/24/2003 Entered By: MDP Plan Approved: 02/18/2003 Issued: 02/18/2003 Inspect Area: Owner: ONIMAC CORP 12520 HIGH BLUFF DR#100 SAN DIEGO CA 92130 02/18/03 0002 01 CGR .V, Plan Check Revision Fee Additional Fees $600.00 $0.00 Total Fees:$600.00 Total Payments To Date:$0.00 Balance Due:$600.00 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. f S"~ Plan Ck. Deposit Validated By_ Date Address (Include Bldg/Suite #)Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use Description of Work SO. FT.ifof Stories # of Bedrooms # of Bathrooms Name Address City State/Zip Telephone # Name Address City State/Zip Telephone * (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basts for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than fjve hundred.dqllars ISIjOOll. Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License 9 Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of fre work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [*100J OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, i shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage la unlawful, and shall subject an employer to criminal penalties and civil tines up to one hundred thousand dollars (9100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code. Interest and attorney's fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES CJNO 2. I (have / have not} signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate, I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit Issued by the building Officl&SLinder the prflvisioiwof this Code shall expire by limitation and become null and void if the byikflng or work authorized by such permit is not commenced within 180 daVajtromjhe dafc of jCph permit or if the building or work authorized by such permit Is suspenc at any time after the work is commenced^0r a period of 18 APPLICANT'S SIGNATUR jitding Code). or abandoned WHITE: File YELLOW: Applicant PINK: Finance Corporation In Partnership with Government for Building Safety DATE: 2/12/03 Q A££LICANT JURISDICTION: Carlsbad P FEAN REVIEWERa FILE PLAN CHECK NO.: 02-3120 (PCRO3-15) SET: H PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT NAME: SeaSilver TI Revisi< The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck, The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: ™ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: . Telephone*: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB n EJ D PC 2/6/03 trnam«.dot Corporation In Partnership with Government for Building Safety DATE: 2/4/O3 Q ABRJ4CANT JURISDICTION: Carlsbad crPtAN REVIEWER Q FILE PLAN CHECK NO.: O2-3120 (PCROi-15) SET: I PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT NAME: SeaSilver XI Revision The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Howard Anderson Assoc. 2194 Carmel Valley Road, Del Mar, CA 92014 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Howard Anderson Assoc. Telephone #: (858) 755-5009 Date contacted:^' H/°3 (by: f**) Fax #: (858) 755-1236 Mail ^Telephone Fax/ In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB n EJ D PC 1/28/03 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 4- Fax (858) 560-1576 Carlsbad 02-3120 (PCR02-15) 2/4/03 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: O2-312O (PCR02-15) JURISDICTION: Carlsbad OCCUPANCY: B, Fl, SI USE: Office, Mfg &Sstorage TYPE OF CONSTRUCTION: III N ACTUAL AREA: 40,566 ALLOWABLE FLOOR AREA: Unlimited STORIES: one HEIGHT: No Change SPRINKLERS?: yes OCCUPANT LOAD: 298 REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 1/28/03 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck Mendenhall COMPLETED: 2/4/O3 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC, The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot Carlsbad O2-3120 (PCR02-15) 2/4/03 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Panic hardware is required on exit doors from A-3 occupancies. UBC 1007.2.5. Door D68, D66, D13 & D15 and D30 must be equipped with panic hardware. The door schedule for door D68 indicates notes A & H apply. Note (A' indicates standard lever set hardware and note (H' indicates panic hardware. Both of these types of hardware are not compatible. The schedule for doors D66 & D30 do not indicate panic hardware. 2. If the Security office is to be used as the one of the two primary exits from the Training Room, Emergency exit illumination is required within the Security office. Sheet E-3 of the plans does not show the emergency illumination within the Security office. 3. The revised MECH-1 form, dated 1/23/03, for the mechanical equipment must be imprinted on sheet M-1. The revised plans included the MECH-1 form dated 10/14/02. 4. Show on sheet P-0 that the main drain line has cleanouts every 100 ft. There is only one main line clean out shown on sheet P-0. 5. The original approved plumbing plans show that the main water service line is a 2-1/2" serving 312 FU. The water pipe sizing table on sheet P-2 show that a min. 2-1/2" line is required. The revised plan sheet P-3 shows that he main line is only a 2" and undersized for the proposed demand. Carlsbad 02-3120 (PCRO2-15) 2/4/O3 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 0^-312O (PCR02-15) 2/4/03 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad 15) PLAN CHECK NO.: 02-3120 (PCR02- DATE: 2/4/03PREPARED BY: Chuck MendenhaU BUILDING ADDRESS: 2310 Camino Vida Roble BUILDING OCCUPANCY: B, Fl, SI TYPE OF CONSTRUCTION: III N BUILDING PORTION Tl revised area Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 24000 cb Valuation Multiplier 28.00 By Ordinance Reg. Mod. VALUE ($) 672,000 672,000 $2,227.48 Plan Check Fee by Ordinance Type of Review: DRepetiBve Fee Repeats Complete Review D Other r—| Hourly D Structural Only Hour* Esgll Plan Review Fee $1,447.86 $1,247.39 Comments: Sheet 1 of 1 macvalue.doc Carlsbad Fire Department 03015 1635 Faraday Ave. Carlsbad, CA 92068 * Plan Review Requirements Category: Date of Report: 02/14/2003 Fire Prevention (760) 602-4660 Building Plan Reviewed by: Name: Address: Brent Waters P.O. Box231925 City, State: Encinitas CA 92023 Plan Checker: Job Name: Seasilver, inc. job #: 03015 Job Address: 2310 Camino Vida Roble Bldg #: PCR03015 Ste. or Bldg. No. Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. D Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job # 1 fit pnH 3rrl 03015 FDFile# nthAr Arjpnny IH TITLE 24 REPORT Title 24 Report for: SEASILVER 2310 CAMINOVIDAROBLE CARLSBAD, CA 92009 Project Designer: Report Prepared By: HADI MAHZARI ENERGY CONSULTING GROUP 8015 BALBOA AVENUE SAN DIEGO, CA 92111 (858) 268-0660 Job Number: Date: 1/23/03 The EnergyPro computer program has been used to perform the calculations summarized in this compliance repvt. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidentia! 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 ByEnergySoft Job Number: User Number: 2984 \ 0 Ti V o a ^Gi t) ^ r r 5 ai co 3a o m m Qs^j <>a ffl § " S8 Q5 g< g