Loading...
HomeMy WebLinkAbout2310 CAMINO VIDA ROBLE; 104; CB112163; Permit01-25-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB112163 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: RICHARD LUND 203 SAN ELIJO AVE STE.120 CARDIFF 92007 619-920-2131 COMM 0 5B Status: Applied: Entered By: Plan Approved: 2310 CAMINO VIDA ROBLE CBAD St: 104 Tl Sub Type: 2130500800 Lot#: $725,621.76 Construction Type: fR6f6r6nc6 ^* NO. COAST CHURCH: 19,548 SF T INVOLVES SOME OF EXISTING STE. 104 AND INCORPORATING Issued: Inspect Area: Plan Check#: Owner: R J VIDA ROBLE INVESTORS LLC 2333 STATE ST #200 CARLSBAD CA 92008 ISSUED 10/11/2011 JMA 01/25/2012 01/25/2012 Building Permit $3,013.94 Meter Size Add'l Building Permit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $2,109.76 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $152.38 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $93.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $317.50 Other Building Fee $0.00 MECHANICAL TOTAL $43.50 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Addl Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Reel. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SB1473) Fee $28.00 HMP Fee ?? Fire Expedited Plan Review $1,105.00 Green BIdg Standards Plan Chk ?? TOTAL PERMIT FEES $6,863.08 Total Fees: $6,863.08 Total Payments To Date: $6,863.08 Balance Due: $0.00 Inspector: FINAL ABPR Date: VAL Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, resen/ations, or other exactions hereafter collectively referred to as lees'exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure fo timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees In connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previousiv been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise expired. ^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718/2719 Fax: 760-602-8558 www.ca risbadca .gov Plan Check No.(CSt \ ' 2-{ (o3> Est. Value ^ IZS^QTJ.^t, Plan Ck. Deposit Date fofII ho SWPP /06 JOB ADDRESS ^3/^ y:,*^M ^^/-^ SUITE#/SPACE#/UNIT# ca TENA CT/PROJECT # # OF UNITS * BEDROOMS * BATHROOl )0M^ T TENANT BUSINESS NAME DESCRIPTION OF WORK: /ncluda Square Feet of >Ufscte(/ Araa(s; CONSTR. TYPE II' ,f^^t^ //l^Az^ ^!/c^^^ZU^/^/<^ Uig-/' iS(SF) I DECKS (SF) I FIREFlACE | AIR CONDITIONING |FIRESI2B« EXISTING USE PROPOSED US^ GARAGE (SF) APPLICANT NAME (Primary Coatact) ij^ / / / / ADDRESS' 7 ~_ } J CITY ^ > KA ^ STATE siw'E FIR EFFACE YES a # NO • AIR CONDITIONING YES • NOO FIRESeBMMCERS YES • NOD APPUCANT NAME (Secondaiy Contact) ADDRESS ZIP CITY STATE ZIP EMAIL 0 FAX PHONE FAX EMAIL PROPERTY OWNER NAME . . I CONTRACTOR Bl BUS. NAME . ADDRESS ADDRESS STATE C4 ZIP STATE ZIP PHONE FAX EMAIL ARCH/DESIGNER NAME iADDRESs/ PHONE FAX ChJIAII ' EFMII: ' STATE LIC.# I CLASS ICnYBlBjUajL ^ ^ ARCH/DESIGNER NAME &W3DRESS tSBuE STATE LIC. # (Sec. 7031.5 Business and Professions Code; Any City or County which requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor's License Law (Chapter g, commending with Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORK£l?S' COMPENSATION Workers' Compensation Declaration: //lereAy affimi under penalty ot peijuiy one ot the Ibllowing declarations: n I have and will maintain a certiiicate of consent to self-insure for woriters' compensation as provided by Section 3700 of the Labor Code, for the perfonnance of the worl< for which this pennit is issued. > issued. My workers' compensation insurance carrier and policy Expiration Date I ^/ ~ / 3 I have and will maintain workers' compensation, % required by Section 37(X) of th&Labor Code, for the performance of the work for which this permit is isi ^ number are: Insurance Ca.C» mPAilt Io A) Pf(ofiT:<3tS , Policy No. /</<J)C tXlOLa& b - <S I This section need not be completed ifthe permit is Ibr one hundred dollars ($100) or less. n Certificate of Exemption: I certify that in the perfonnance of the work for which this pennit is issued, I shall not employ any person in any manner so as to become subject to the Woikers' Compensation Laws of I Califomia. WARNING: Failure to secure workers' compensatian coverage Is unlawful, and shall subject an employerto criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in / addition to the cost of compensatioivdamages as provided^ in Section 3706 of the Labor code, interest and attomey's fees. ^ ygS" CONTRACTOR SIGNATURE ^-^^^j^^jC^/^.^i^/?^t>g-t^^ ^GENT DATE / ^— /Z- OWNEn-SUItOjb'R DECLARATION / hereby affirm that I am exempt Irom Contractor's Ucense Law tor the follomng reason: • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided Ifiat such improvements are not Intended of offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's Ucense Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). • I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement • Yes • No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the fallowing person (firm) to provide the proposed construction (include name address/phone/contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): VSTPROPERTY OWNER SIGNATURE •AGENT DATE COMPLETE THIS SECTION FOR NON-RESIOENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant requited to submit a business plan, acutely hazanlous materials registration form or risl< management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? OYes Wfio Is the applicant or future building occupant required to obtain a pennit from the air pollution control distnct or air quality management district? • Yes 'gt No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? OYes ijCNo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affinn that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certif that I have lead the applkatkin and state thmtlieabcm infbrrnatton Is conect and that the infbtrnaV^ I hereby authorize representative of the City of Carlsbad to enter upon Ihe above mentbned property fbr inspection puiposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA penmit is required t)r excavations over S'C deep and demolitbn orconstrtictbn of strudunes over 3 stories in height EXPIRATION: Every pemiit issued by the Building Offidal under Ihe provisbns of this Code shall expire by limitation and become null and void if ttie building or mk aulhorized by such peimit is not oommenoed wilhin 180 days from Ihe date of such permit or If Ihe building or work authorized by such permit is suspended or abandoned at any time after the work is commenced fbr a perbd of 180 days (Section 106.4.4 Unifbmn Building Code). ^APPUCANT'S SIGNATURE "^^l!^ {^^^/ianf/^'^^^Z/ DATE Inspection List Permlt#: CB112163 Type: Tl Date Inspection [tem COMM NO. COAST CHURCH: 19,548 SF T INVOLVES SOME OF EXISTING STE. 104 Inspector Act Comments 06/29/2012 89 Final Combo MC Fl FIRE APPROVED 06/28/2012 89 Final Combo -Rl FIRE IS OK 06/28/2012 89 Final Combo MC PA OK TO OCCUPY, WAITING FOR FINAL FIRE SIGNATURE 05/24/2012 84 Rough Combo PB AP 05/08/2012 14 Frame/Steel/Bolting/Weldin MC AP CONTROL RM 05/03/2012 17 Interior Lath/Drywall MC AP 04/26/2012 84 Roggh Combo MC PA PHASE 3 WALLS ONLY- 04/05/2012 89 Final Combo MC PA PHS 1 AND 2 PARTIAL OCCUPANCY ONLY SEE CARD 03/19/2012 84 Rough Combo MC PA PHASE 1 & 2 T-GRID, MINOR PICK UP 03/15/2012 84 Rough Combo MC CO T-GRID 02/29/2012 17 Interior Lath/Drywall MC PA WALLS (g 118 & 127/130 & HARD LID € 107/108 02/27/2012 17 Interior Lath/Drywall MC PA WALLS ONLY SEE CARD 02/24/2012 21 Underground/Under Floor MC AP SEE CARD, RM 107/108 AND 126 02/24/2012 84 Rough Combo MC PA WALLS ONLY @ 107-108, SEE CARD 02/21/2012 14 Frame/Steel/BoltingA/Veldin MC PA WALLS, SEE CARD 02/21/2012 24 Rough/Topout MC WC 02/21/2012 34 Rough Electric MC PA WALLS, SEE CARD 02/21/2012 44 Rough/Ducts/Dampers MC WC Friday, June 29, 2012 Page 1 of 1 cnMCimM HMlliiiliig iMinetiM Dept: Building Engineering Planning CIVIWD St Lite Fire Plan Check #: Permit*: Project Name: Address: Contact Person: Sewer Dist: CB112163 NO. COAST CHURCH: 19,548 SF T INVOLVES SOME OF EXISTING STE. 104 AND INCORP 2310CAMINO VIDA ROBLE #104 Lot: Phone: CA Water DIst: CA Date: Permit Type: Sub Type: 06/27/2012 Tl COMM Inspected By: 0( Inspected By: Inspected By: Date . Inspected: Date . Inspected: Date . Inspected: Approved Approved: Approved: Disapproved: Disapproved: Disapproved: Comments: Carlsbad 11-2163 1/11/12 EsGil Corporation In Partnership witH government for (BuiCcfing Safety DATE: 1/11/12 •.^EELICANT JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 11-2163 SET: III PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT NAME: North Coast Church TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. I 1 The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. I I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Perstyf REMARKS: Each sheet of th^^r^jlrwcjtiral pages must be signed by the designed assuming responsibility for the plans. By: Chuck Mendenhall * / Enclosures: EsGil Corporation • GA • EJ • PC 1/6/12 EsGil Corporation In PartnersHip witH government for (BuiUing Safety DATE: 12/20/11 •.^gUCANT JURIS^ JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 11-2163 SET: II PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT NAME: North Coast Church TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: Grupo Pacific, Att'n: Richard Lund 2033 San Elijo Ave, #120, Encinitas, CA 92007 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Richard Lund Telephone #: (760) 730-3351 Date contacted: I'^UiIII (by:P/2.) Email: dlund@grupopacific.com Fax #: ^ Mail ^ Telephone Fax In Person • REMARKS: By: Chuck Mendenhall Enclosures: EsGil Corporation • GA • EJ • PC 12/14/11 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 11-2163 12/20/11 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. 7. The revised occupancy from office to worship requires increased outside air requirements. See Calif Energy Standards Section 121. Basically the energy standards require OSA of 1.07 CFM/sq ft for worship. The response to this item was" The increased OSA for worship are found on sheet M1.1 Note #6.1 did not find any required OSA information on sheet M1.1. Include a legible schedule ofthe existing equipment, List on the schedule the OSA for each of the HVAC units in the building. Also, reference on the mechanical plan the HVAC unit number that relates to the equipment schedule. DISABLED ACCESS DRINKING FOUNTAINS 8. Plans shall indicate that drinking fountains comply with Section 1115B.4.6 as either: The response directs me to the architectural sheet TI-5.0 which now shows the drinking fountains not within the walkway. However, the plumbing plans on sheet P-2 still shows the drinking fountains with the corridor walkway. Provide consistent plans. Located completely in an alcove, >32" in width and >18" in depth. Positioned completely between wing walls. Positioned to not encroach into accessible pedestrian ways. END OF RECHECK To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the Carlsbad 11-2163 12/20/11 plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In (PartnersHip with government for (Buiding Safety DATE: 10/19/11 • AEf •(JURIS. JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 11-2163 SET: I PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT NAME: North Coast Church TI r~| The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. X The applicant's copy of the check list has been sent to: Grupo Pacific, Att'n: Richard Lund 2033 San Elijo Ave, #120, Encinitas, CA 92007 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Richard Lund Telephone #: (760) 730-3351 Date contacted:'<2l''^f" (by.y^) Email: dlund@grupopacific.com Fax #: t Mail Telephone Fax In Person n REMARKS: By: Chuck Mendenhall Enclosures: EsGil Corporation • GA • EJ • PC 10/13/11 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 Carlsbad 11-2163 10/19/11 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 11-2163 JURISDICTION: Carlsbad OCCUPANCY: A-3 USE: Church and Sunday School TYPE OF CONSTRUCTION: IIB ACTUAL AREA: 19,548 ALLOWABLE FLOOR AREA: Non separated = 45,125 STORIES: one HEIGHT: No change SPRINKLERS?: Yes OCCUPANT LOAD: Sancturary= 242 Class rooms/ Office= 221 REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 10/13/11 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck MendenhaU COMPLETED: 10/19/11 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list for a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. , Carlsbad 11-2163 10/19/11 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Detail on the plans the construction of the "All Glass" partitions at the Book Store #127 and Classroom #129. Show the thickness and type of glass the method of anchoring the top and bottom to the partitions and how you intend to provide out-of-plane lateral support for the wall. 2. Expand detail 7/TI-8.0 to show how the soffit framing will be supported laterally with bracing to the roof structure ( out-of-plane loads). 3. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 This applies to the "All Glass" partitions in rooms 129 & 127. 4. Note on the cover sheet of the plans whether the class room use is for full time education or part time 5. Expand the notes for the construction of the suspended ceilings on sheet TI-8.0, details 12 & 8 to include the fo9llowing: in Seismic Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as follows: a) All ceilings shall use a Heavy Duty T-bar grid system. b) The width ofthe perimeter supporting closure angle shall be not less than 2 inches. c) Ceiling areas over 2500 ft.^ must have seismic separation joints or full height partitions. 6. Show on the plans the location of the relocated electrical panels. See demolition Note #9 on sheet TI-4.0. The location of the removed panels is not show on the electrical power plan. 7. The revised occupancy from office to worship requires increased outside air requirements. See Calif Energy Standards Section 121. Basically the energy standards require OSA of 1.07 CFM/sq ft for worship. DISABLED ACCESS REVIEW LIST • DRINKING FOUNTAINS 8. Plans shall indicate that drinking fountains comply with Section 1115B.4.6 as either: a) Located completely in an alcove, >32" in width and >18" in depth. Carlsbad 11-2163 10/19/11 b) Positioned completely between wing walls. c) Positioned to not encroach into accessible pedestrian ways. 9. Drinking fountains shall be accessible to individuals who use wheelchairs and to those who have difficulty bending or stooping. This can be accommodated by the use of "hi- low" fountains. Section 1115B.4.6. . SERVICE COUNTERS 10. The tops of THE Book Store service counter shall be 28" to 34" from the floor. The disabled accessible section of counter shall be located at a section of counter that is at least 36" wide and no more than 28" to 34" high. Section 1122B.4. GROUP A OCCUPANCIES 11. Note that assistive listening device systems shall be installed in the following areas for people with hearing impairments, per Section 1104B.2; a) Assembly areas. b) The number of personal receivers required to be available shall be equal to 4% of the total seats provided, but ^2. 12. Revise plans to show that the proposed religious facility is made accessible, pr Section 1104B.6, as follows: a) Wheelchair access shall be provided to: i) Raised platforms. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 11-2163 10/19/11 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 11-2163 PREPARED BY: Chuck Mendenhall DATE: 10/19/11 BUILDING ADDRESS: 2310 Camino Vida Roble BUILDING OCCUPANCY: A-3 TYPE OF CONSTRUCTION: II B BUILDING PORTION AREA (Sq.Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Chucrch/school T 19548 City Est 725,621 Air Conditioning Fire Sprinklers TOTAL VALUE 725,621 Jurisdiction Code cb By Ordinance BIdg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: • Repetitive Fee Repeats • Complete Review • Other Hourly EsGil Fee • Structural Only Hr. @ $3,013.94 $1,959.06 $1,687.81 Comments: Sheet 1 of 1 macvalue.doc + BUILDING PLANCHECK Development Services NN^*^ ^"^^ Development Engineenng CITY OF CHECKLIST ISSS Faraday Avenue CARLSBAD QUICK-CHECK/APPROVAL 76O6022750 \t\^^i^t www.carlsbadca.gov ENGINEERING Plan Check for CB 11- 2163 Date: October 17,2011 Project Address: 2310 Camlno Vida Roble APN:213-050-08-00 Project Description: TENANT IMPROVEMENT INVOLVES SOME OF Valuation: EXISTING STE. 104 AND INCORPORATING ALL OF STE 105 AS ONE SPACE (CHURCH/OFFICE) ENGINEERING Contact; Linda Ontlveros Phone: 760-602-2773 Email: linda.ontiveros@carlsbadca.gov Fax: 760-602-1052 n RESIDENTIAL [Zl TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$20,000.00) • PLAZA CAMINO REAL • CARLSBAD COMPANY STORES COMPLETE OFFICE BUILDING [ZJ OTHER: 100% FEE'D (SEE CB092015 FOR OFFICE TO CHURCH CONVERSION) OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMFr BY REMARKS DATE: October 17,2011 Notification of Engineering APPROVAL has been sent to via on E-36 Page 1 of 1 REV 4/30/11 CITY CARLSBAD O F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment priority projects incorporate Permanent Stonn Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP). Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results ofthe questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject additional criteria called 'Priority Development Project Requirements'. Many aspects of project site design are dependent upon the storm water standards applied to a project. Applicant responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by the applicant, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City. If applicants are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, they are advised to seek assistance from Land Development Engineering staff. A separate completed and signed questionnaire must be submitted for each new development application submission. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. In addition to this questionnaire, applicants for construction permits must also complete, sign and submit a Project Threat Assessment Form to address construction aspects of the project. Please answer tiie questions below, follow the instructions and sign the form at the end. 1. Is your project a significant redevelopment? DEFINITION: Significant redevelopment is defined as the creation, addition or replacement of at least 5,000 square feet of impervious surface on an already existing developed site. Significant redevelopment includes, but is not limited to: the expansion of a building footprint; addition to or replacement of a structure; structural development including an increase in gross floor area and/or exterior construction remodeling; replacement of an impervious surface that is not part of a routine maintenance activity; and land disturbing activities related with structural or impervious surfaces. Replacement of impervious surfaces includes any activity that is not part of a routine maintenance activity where impervious material(s) are removed, exposing underlying soil during construction. If your project IS considered significant redevelopment, then please skip Section 1 and proceed with Section 2. If your project IS NOT considered significant redevelopment, then please proceed to Section 1. E-34 Page 1 of 3 REV 3/23/10 ^ CITY CARLSBAD O F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov SECTION 1 NEW DEVELOPMENT PRIORITY PROJECT TYPE Does you project meet one or more of the following criteria: YES NO 1. Housina subdivisions of 10 or more dweilina units. Examoles: sinale familv homes, multi-familv homes, condominium and apartments 2. Commercial - areater tfian 1-acre. Anv develooment other than heaw industry or residential. Examoles: hospitals; laboratories and other medical facilities; educational institutions; recreational facilities; municipal facilities; commercial nurseries; multi-apartment buildings; car wash facilities; mini-malls and other business complexes; shopping malls; hotels; office buildings; public vtrarehouses; automotive dealerships; airfields; and other light industrial facilities. 3. Heaw industriai / industrv- areater tiian 1 acre. Examples: manufacturina olants. food processina olants, metal working facilities, printing plants, and fleet storage areas (bus, truck, etc.). 4. Automotive reoair stiOD. A facilitv cateaorized in anv one of Standard Industrial Classification (SIC) codes 5013, 5014, 5541, 7532-7534, and 7536-7539 5. Restaurants. Anv ^cilitv that sells oreoared foods and drinks for consumotion. includina stationarv lunch counters and refireshment stands selling prepared foods and drinks for immediate consumption (SIC code 5812), where the land area for development is greater than 5,000 square feet. Restaurants where land development is less than 5,000 square feet shall meet all SUSMP requirements except for structural treatment BMP and numeric sizing criteria requirements and hydromodification requirements. 6. HIiiside develooment Anv develooment that creates 5.000 sauare feet of impervious surface and is located in an area with known erosive soil conditions, where the development will grade on any natural slope that is twenty-five percent (25%) or greater. 7. Environmentaiiv Sensitive Area (ESA}\ All development located within or directiv adiacent^ to or discharoina directly" to an ESA (where discharges from the development or redevelopment will enter receiving waters within the ESA), which either creates 2,500 square feet of impervious surface on a proposed project site or increases the area of imperviousness of a proposed project site to 10% or more of its naturally occurring condition. 8. Parldna lot Area of 5.000 sauare feet or more, or with 15 or more oarkina soaces. and ootentiallv exoosed to urban runoff 9. Streets, roads, hiatiwavs. and freewavs. Anv paved surface that is 5,000 square feet or qreater used for the transportation of automobiles, trucks, motorcycles, and other vehicles 10. Retail Gasoline Outlets. Servina more than 100 vehicles per dav and areater than 5.000 sauare feet / 11. Coastal Develooment Zone. Anv oroiect located within 200 feet of the Pacific Ocean and (^) creates more than 2500 square feet of impermeable surface or (2) increases impermeable surface on property by more than 10%. / 12. More than 1-acre of disturbance. Proiect results in the disturbance of more than 1-acre or more of land and is considered a Pollutant-generating Development Project^. / 1 Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special Biological Significance by tlie State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent environmentally sensitive areas which have been identified by the Copennittees. 2 "Directly adjacent' means situated within 200 feet of the Environmentally Sensitive Area. 3 "Discharging directly to" means outflow from a drainage conveyance system that Is composed entirely of flows from the subject development or redevelopment site, and not commingled with flow from adjacent lands. 4 Pollutant-generating Development Projects are those projects that generate pollutants at levels greater than background levels. In general, these Include all projects that contribute to an exceedance to an impaired water body or which create new impervious surfaces greater than 5000 square feet and/or Introduce new landscaping areas that require routine use of fertilizers and pesticides. In most cases linear pathway projects that are for infrequent vehicle use, such as emergency or maintenance access, or for pedestrian or bicycle use, are not considered Pollutant-generating Development Projects if they are built with pen/ious surfaces or if they sheet flow to surrounding pervious surfaces. Section 1 Results: .If you ansvi«red YES to ANY of the questions above your project is subject to Priority Development Project requirements. Please check the "meets PRIORITV DEVELOPMENT PROJECT requirements" box in Section 3. A Storm Water Management Plan, prepared in accordance with City Stomi Water Standards, must be submitted at time of application. If you answered NO to ALL of the questions above, then your project is subject to Standard Stormwater Requirements. Please check the "does not meet PDP requirements" box in Section 3. E-34 Page 2 of 3 REV 3/23/10 ^ CITY CARLSBAD O F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov SECTION 2 SIGNIFICANT REDEVELOPMENT Complete the questions below regarding your redevelopment project: YES N d 1. Project results in the disturbance of more than 1 -acre or more of land and is considered a Pollutant-generating Development Project (see definition in Section 1). If you answered NO, please proceed to question 2. If you answered YES, then you ARE a significant redevelopment and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. 2. Is the project redeveloping an existing priority project type? (Priority projects are defined in Section 1) If you answered YES, please proceed to question 3. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. 3. Is the proiect solelv limited to |ust one of the following: a. Trenching and resurfacing associated with utility work? b. Resurfacing and reconfiguring existing surface parking lots? c. New sidewalk construction, pedestrian ramps, or bike lane on public and/or private existing roads? d. Replacement of existing damaged pavement? If you answered NO to ALL of the questions, then proceed to question 4. If you answered YES to ANY of the questions then you ARE NOT a significant redevelopment and your project is subject to Standard Stormwater Requirements. Please check the "does not meet PDP requirements" box in Section 3 below. 4. Will your redevelopment project create, replace, or add at least 5,000 square feet of impervious surfaces on an existing development or, be located within 200 feet of the Pacific Ocean and (1 )create more than 2500 square feet of impermeable surface or (2) increases impermeable surface on the property by more than 10%? If you answered YES, you ARE a significant redevelopment, and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. SECTION 3 Questionnaire Results: Q My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater criteria I per the SUSMP and must prepare a Storm Water Management Plan for submittal at time of application. ^ ^ My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP. Applicant Infonnation and Signature Box This Box for City Use Only ^^7i Cam/'I" VWi.' Applicant Name: ^ Assessor's Parcel Numbers): ^^7i Cam/'I" VWi.' Applicant Name: ^ Applicant Title: . Applicant Signature: Date: ^ City Concurrence: , > 1 1 -its^ NO J \./ Date: lo/n/ii Project ID: , E-34 Page 3 of 3 REV 3/23/10 ^ CITY OF CARLSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type(s) of construction permit: • Building Permit • Right-of-Way Permit |Vly project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more ofthe following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* Afo Tflreat>^s5essment Criteria *">IQ^ My project qualities as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because ' it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tierl - Low Threat Assessment Criteria • My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tfer2 - Moderate Threat Assessment Criteria • My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuantto the Carisbad Grading Ordinance (Chapter 15.16 of the Carisbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturised area is located along or within 30 feet of a storm drain inlet an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 • Significant Threat Assessment Criteria • My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or • My project Is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, • My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water mnoff or non-stomi water discharge(s). / certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must stiff adhere to, and at all times during construct/on activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carisbad Municipal Code and to City Standards. "The City Engineer noay authorize minor variances from the Storm Water Threat Assessment Criteria in spedal circumstances where it can be shown that a lesser or higher Constmction SWPPP Tier Level is wan'anted. Project Address: .f -r, /1 Assessor Parcel No. O^r/Ow^^ AuthjitoJ /^ntNape: TlUe: , Owner/Ownw's Authorized Agent Signature: ^ Date: City C^urrence: cms QNO Project ID: B-24 Page 1 of 1 Rev.03/09 • • PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CBl 1-2163 Address 2310 Camino Vida Roble Planner Greg Fisher Phone (760) 602- 4629 APN: 213-050-08 Type of Project & Use: Church Net Project Densitv:N/A DU/AC Zoning: PM General Plan: Pl Facilities Management Zone: 5 CFD (In/out) #_Date of participation: Remaining net dev acres: Circle One (For non-residential development: Type of land used created by this permit: ) Legend: ^ Item Complete • Item Incomplete - Needs your action Environmental Review Required: YES • NO • TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES IEI NO • TYPE CUP 09-03A APPROVAL/RESO. NO. 6799 DATE 9/7/11 PROJECT NO. CUP 09-03A OTHER RELATED CASES: Compliance with conditioris or approval? If not, state conditions which require action. Conditions of Approva|>4j G O Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES QNO El CA Coastal Commission Authority? YES Q NO D If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Pemiit Required or Exempt): • • Habitat Management Plan Data Entry Completed? YES • NO ^ If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) • • Inclusionary Housing Fee required: YESD NO ^ (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Traclting Form (form P-20) completed: YES • NO N/AD Rev 6/11 Site Plan: Kl • • Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44 - Neigiiborhood Arcliitectural Design Guidelines S • • 1- Applicability: YES • NO Kl • • • 2. Project complies: YES • NOO Kl • • • • Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required. Required. Required. Required. Required 2. Accessory structure setbacks: • • Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: Required. Required. Required. Required. Required. Required. Shown. Shown. Shown. Shown. Shown. Shown. Shown. Shown. Shown. Shown, Shown • • 4. Height: Required Shown 5. Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments Prior to buildina n^rmit. condition 13 in Planning Commission Resolution 6799 must be satisfied. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Rev 6/11 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 01-23-2012 Reviewed by: Name: Address: RICHARD LUND 203 SAN ELIJO AVE. STE. 120 CARDIFF CA 92007 Permit #: CBl 12163 Job Name: NO. COAST CHURCH: 19,548 SF T Job Address: 2310 CAMINO VIDA ROBLE CBAD St: 104 INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adgjudlUIH LtillLlULL 1 iffrtgWPWPHElLiiiiiuu uuiiialiaa^j»^^y|ie.aim^j^alfiXQdes-aD^^ Please review carefully all comments flttflP.hPiH^ g^aaaa—W^WWHffRffSrpggarv n1an^n3?ffl'W<HBi<Mfltior|^^ ^vitVi phia^Hppg "clouded", to this officeJauiiiiM^^ffR^pproval. Conditions: Cond: CON0005159 [MET] unt THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLL\NCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 01/23/2012 By: cwong Action: AP CONDITIONAL RECOMMENDATION FOR APPROVAL Page: 1 of 3 BLDG. DEPT COPY CONDITION: SHEET Tl-10 THE DEPUTY FIRE MARSHAL REQUIRES THE CALIFORNIA STATE FIRE MARSHAL LISTINGS FOR FINISH AND INSULATION MATERIALS PRIOR TO APPROVAL OF THIS PLAN. THE APPROVAL AND PERMIT FOR CB112163 WILL NOT BE ISSUED WITHOUT THIS fNFORMATION BEING PROVIDED WITH THE FINAL SET. EACH SHEET OF "THE PLANS MUST BE 'SIGNED BY THE PERSON RESPONSIBLE FOR THEIR PREPARATION, EVEN THOUGH THERE ARE NO STRUCTURAL CHANGES. BUSINESS AND PROFESSIONS CODE. Daryl K. James & Associates, Inc. Checked by: Darvl K. Janr>es 205 Co//na Terrace Date: January 17. 2012 Vista, CA 92084 T. (760) 724-7001 Email: kitflre@sbcglobal.net APPLIC/^NT: Richard^Lund JURISDICTION: Carlsbad Fire Department PROJECT NAME: North Coast Church PROJECT ADDRESS: 2310 Camino Vida Roble PROJECT DESCRIPTION: CB112163 19,548 sf. tenant improvement in existing church This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. COMMENTS f T-S1.0 Deferred Submittals ^ •2010 Fire Sprinkler System CFC 902.1 & NFPA 13 ••2010 Fire Alarm Systftm CFC 907.1.1 &'NFPA 72 Add 907.2.1.1 specific to Group A and CBC 907.2.3 specific to Group E. (See EP-3.0 comments). •Clarify if Kitchen Hood & Duct, as denoted on Sheet TS1-1 ^ will be listed under Deferred Submittals (See General Notes/Fire Safety and Prevention Notes TS-1.0 & T-S1.1 comments) H&D notes removed. Project Data • Construction Type - Specify Type ll-A or ll-B Occupancy Type - Denote all occupancy types in Suite 104. Specify accessory areas. See comments for EP- • Denote adjacent occupancy types. See SP-2.0 NIC hashed area. Sheet Index ' ^ , ^ ' • Revise Sheet index to match sheets in this set. (Several) Change EX sheets to EP sheets and change T1-5.1 to Door& Window Schedule T-10.0 and P-1, P-2 and P-3 are missing. •Sheet E0.1 is missing from this set. Provide Electrical Lighting Plan . : General Notes/Fire Safety and Prevention Notes TS-1.0 & T-S1.1 • Delete all notes not applicable to the tenant improvement in this existinq suite, i.e. kitchen cooking equipment, elevator requirements and all other notes that reference requirements fire protection svstems and equipment. Specific to for new building structures. Notes should be limited to tenant improvements specific to this proiect EP-3.0 & EP3.1 •Scale on Title Btock is 1/8"=ro yet scale on Exit'^lan is 3/32" = 1'0". Please clarify acTual scale. • Provide furnishing layout throughout including, but not limited to sanctuary seating. Denote the occupancy classification of each room or area. CBC Chapter 3. See attached IBC Code Commentary on E Occupancies in places of religious worship, from the IBC Code and Commentary Sec. 305.1. Several closely spaced classrooms with an aqqreqate OL >100 = Group E Occupancies. "Denotfe the square footage, occupant load factor and occupant load of each room or area based on the function of the space. See CBC Table 1004.1.1 Column heading Function of Space. Paqe 2 of 3 •Denote accessory use areas. Revise as per previous comment. Cross-out accessory in all nonseparated occupancies. See CBC 508.3 • Describe the use of Family AreaJ 28 » •Denote-the second required exit, equipped with panic hardware, from Family Area 128. •Show path of egress and exit access travel distance from this second exit to a separate public way. When 2 exits are required there shall not-be a convergence of egress paths. CBC 1015.2.1 Denoted on Additional Sheet EP-3.2 •Show Common Paths of Egress Travel (CBC 1014.3) and Exit Access Travel Distance (CBC 1016) from all areas to a public way. Denote travel lengths and number of occupants per exit. See previous comment regarding occupant loads. •EP3.1 ^Please denote compliance with CBC 1028 sections applicable to means of egress in an assembly occupancy Including, seating, but not limited to, required width of egress to a public way. •Allowable paths of egress from a Group A occupancy is 30 ft. not 75 feet as denoted on the left side of this sheet. Please revise this note and denote paths of egress from Group A occupancies complying with 1028.8. •CBC 1028.8 Common of egress travel requirements are not applicable to Group E Occupancies, only to Group A occupancies that are accessory to Group E. Occupancies. (See CBC 1014.3). There is no need to add an exit to Classroom 103. . T1-4.0 •Add the following note: Fire safety during construction and demolition shall comply with CFC Chapter 14. TI-5.0 ' Partition Plan Legend ' , •Identify rated partitions and reference rated assembly details on Sheet TI-8.0. Clarify if there is an existing rated demising wall between the adjacent tenant, on the Partition Plan Legend and on 3m-8.0 details! Partition Plan Identify the rooms west of Youth Classroom 115. ^ • It is recommended that new and/or existing fire extinguishers be located in a visible and readily available location in a common path of egress, preferably near exits. • Denote Occupant load signs in all assembly occupancies. •Classroom-129 - All doors shall be equipped with panic hardware. (Door R-10 not equipped with PH). • Denote the second required exit, equipped with panic hardware, from Family Area 128. Identify accessory use areas. CBC 508.2 Identify incidental use areas and detail compliance with CBC 508.2.5.2. i.e. Storage Room 125 ' • Identify Electrical and Telephone as incidental rooms use areas and detail compliance with CBC 508.2.5.2 Denote all rated assemblies with references to details. Clarify if there is an existing rated demisiog wall between the adjacent tenant, on the Partition Plan Legend and on 3/T1-8.0 details. • Please explain the reason for 90-minute rated exterior exit doors in Sanctuary Area 109.Not Required Partition Notes * • 36. Provide details of room divider, including burning characteristics, in accordance with CBC 803. To be provided on Fjnish Plan THO. Omitted' TI-5.1 • Dopr Notes •Provide a note stating; All doors shall be openable from the egress side without the use of a key or special knowledge or special effort. Door Schedule ' • • E-1 & N-5 - Sign is not applicable, please remove. Doors equipped with panic hardware cannot be locked on i the egress side at any time. •R-5 - Door shall comply with CBC 508.2.5.2 • T1-7.1 . Reflected Ceiling Plan * ^ • Reffected Ceiling Plan does not resemble Partition Plan. Please revise. Okay , Page 3 of 3 • Denote all exit sign locations in accordance with CBC 1011.1. Not shown in several areas. Denote a direction exit sign for the'second exit required from Family Area 128. Provide a directional exit sign to the second required exit to a public way. Exit sign for the second exit does not show the option of exiting to the right. When 2 exits are required there shall not be a convergence of egress paths. CBC 1015.2.1. * Reflected Ceiling l^lan Legend •Add 90-minutes to battery backup for emergency means of egress light fixtures providing 1 foot-candle illumination. •Add 90-minutes to battery backup for and exit signs providing 5 foot-candle illumination. Reflected Ceiling Plan Notes • 11 & 33. Add 'upon approval of deferred system plan, under separate permit, by the AHJ '. See TS1.0 Deferred Submittals. •25. Verify projection screen does not block/disguise exit door. TI-8.1 ' ' • Identify details for rated assemblies. Include UL listings for rated systems, reference* to CBC Table 720.1 Item Number and/or ICC-ER number TI-1Q Provide Sheet T-10.0 Provided * Add a note: All finish materials will comply with the requirements of CBC Chapter 8. Address TI-5.0 Partition Note 36 regarding room divider. Oi^itted Provide a note stating that the burning characteristics, labels and/or California State Fire Marshal listings for finish and insulation materials will be made readily available to fire ahd building inspectors during field inspection. THE NOTE IS TO.ACKNOWLEDGE THAT the Deputy Fire Marshal requjites the California State Fire Marshal listings for finish and insulation materials PRilbiR Tq^APPRO.VAL OF THIS PLAN. The Approval and permit for CBl 12163 will not be issued without this infonnation being provided with the final set? Ml.l Mechanical Plan Check Notes • Revise notes to reference current editions of 2010 CMC and 2010 CBC Plan •Denote locations of supply ducts equipped with smoke detectors on plan. See Mechanical PlanOheck Notes 8&9. No new mechanical equipment. , • Denote Fire/Smoke Dampers on floor plan. Clarify Mechanical Plan Check Note 10. Remove fire damper notes, not applicable to this project. ' Details ' . • Provide details for new equipment. No new mechanical equipment. • Provide fire proofing detail and listing for penetration of fire rated assemblies. N/A Electrical ' Provide lighting plan showing: ^ •Wiring to emergency means of egress light fixtures providing 1 foot-candle illumination equipped with 90- minute minimum battery p^k ' • Exit signs providing 5 foot-candle illumination equipped with 90-tTiinute minimum battery pack. Coordthate emergency lighting fixtures with T1-7.1 See new^omment on T1-7.1 for directional exit sign from •, Family Area 128. Field Verify •Denote exterior lighting equipped with emergency power outside all exterior exits. GRUPO PACIFIC Fire Plan Check Corrections Responses #3 January 7, 2012 Project Name: North Coast Church Project Description: CB 112163; 19,548 sf. Tenant improvement in existing church Project address: 2310 Camino Vida Roble ste. 103, Carlsbad, CA 92008 EP-3.1 1. "Accessory" has been deleted from plans. 2. Distinct paths are shown on new sheet EP-3.2. 3. Allowable paths of egress from a Group A occupancy has been revised to comply with CBC section 1028.8 on sheet EP-3.1. Additional door has been provided from Youth Classroom #103 to meet those requirements. TI-7.1 Reflected Ceiling Plan 4. Exit sign for the second exit from Family Area #128 has been changed to show the option of exiting to the left or the right (added additional chevron directional arrow) as denoted on sheet TI-7.1. Sheet TI-3.2 displays the two paths of exiting. TI-8.1 Detail for rated walls on sheet TI-8.1 has been updated. Reference to table 720.1(2) has been added to construction detail. Reference to current CBC 2506 and 2508 and current ICC-ES Evaluation Report ESR-2457 has been added as well. TI-10.0 A note stating that "The burning characteristics, labels and/or California State Fire Marshal listings for finish and insulation materials will be made readily available to fire and building inspectors during field inspection. Deputy Fire Marshal has requested California State Fire Marshal listings for finish and insulation materials will be made readily available as a condition of approval for this permit," has been added to sheet TI-IO. Mechanical Ml.l Plan 7. Inapplicable damper notes have been removed from Mechanical Plan sheet Ml.l. Electrical 8. Direction for exit sign from Family Area #128 has been updated on Electrical Plan to coincide with Reflected Ceiling Plan sheet TI-7.1 - ^ CORRECTION LIST 3 Page: 1of3 BLDG. DEPT COPY Daryl K. James & Associates, Inc. Checked by: Daryl K. James 205 Co//na Terrace Date: January 7, 2012 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Richard Lund JURISDICTION: Carlsbad Fire Department PROJECT NAME: North Coast Church PROJECT ADDRESS: 2310 Camino Vida Roble 104 PROJECT DESCRIPTION: CBl 12163 19,548 sf. tenant improvement in existing church This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. iNSTRyCTtiii ADDRESS REMAINING COMMENTS PRINTED IN BLUE FONT • Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates along with a descriptive narrative of corrections addressing all comments. • Please direct any questions regarding this review to: Daryl K. James kitfire@sbcglobal.net • Corrected Plans, Response To Corrections, Following Each Comment On This Form. When Available Provide a Copy of Building Dept. (Esgil) Comments as soon as available. TO ENSURE EXPEDITED REVIEW, REVISIONS MUST BE SUBMITTED DIRECTLY TO: DARYL K. JAMES 205 COLINA TERRACE VISTA, CA 92084 COMMENTS T-S1.0 Deferred Submittals •2010 Fire Sprinkler System CFC 902.1 & NFPA 13 •2010 Fire Alarm System CFC 907.1.1 & NFPA 72 Add 907.2.1.1 specific to Group A and CBC 907.2.3 specific to Group E. (See EP-3.0 comments). •Clarify if Kitchen Hood & Duct, as denoted on Sheet TS1-1, will be listed under Deferred Submittals (See General Notes/Fire Safety and Prevention Notes TS-1.0 & T-S1.1 comments) H&D notes removed. Project Data • Construction Type - Specify Type ll-A or ll-B Occupancy Type - Denote all occupancy types in Suite 104. Specify accessory areas. See comments for EP- • Denote adjacent occupancy types. See SP-2.0 NIC hashed area. Sheet Index • Revise Sheet index to match sheets in this set. (Several) Change EX sheets to EP sheets and change T1-5.1 to Door & Window Schedule T-10.0 and P-1, P-2 and P-3 are missing. •Sheet E0.1 is missing from this set. Provide Electrical Lighting Plan General Notes/Fire Safety and Prevention Notes TS-1.0 & T-S1.1 • Delete all notes not applicable to the tenant improvement in this existinq suite, i.e. kitchen cooking equipment, elevator requirements and all other notes that reference requirements fire protection svstems and equipment. Specific to for new building structures. Notes should be limited to tenant improvements specific to this proiect. Page 2 of 3 EP-3.0 &' EP3.r •Scale on Title Block is 1/8"=1'0 yet scale on Exit Plan is 3/32" = I'O". Please clarify actual scale. • Provide furnishing layout throughout including, but not limited to sanctuary seating. Denote the occupancy classification of each room or area. CBC Chapter 3. See attached IBC Code Commentary on E Occupancies in places of religious worship, from the IBC Code and Commentary Sec. 305.1. Several closely spaced classrooms with an aqqreqate OL >100 = Group E Occupancies. Denote the square footage, occupant load factor and occupant load of each room or area based on the function of the space. See CBC Table 1004.1.1 Column heading Function of Space. Denote accessory use areas. Revise as per previous comment. Cross-out accessory in all nonseparated occupancies. See CBC 508.3 • Describe the use of Family Area 128 •Denote the second required exit, equipped with panic hardware, from Family Area 128. EP3.1 Show path of egress and exit access travel distance from this second exit to a separate public way. When 2 exits are required there shall not be a convergence of egress paths. CBC 1015.2.1 •Show Common Paths of Egress Travel (CBC 1014.3) and Exit Access Travel Distance (CBC 1016) from all areas to a public way. Denote travel lengths and number of occupants per exit. See previous comment regarding occupant loads. EP3.1 Please denote compliance with CBC 1028 sections applicable to means of egress in an assembly occupancy including, seating, but not limited to, required width of egress to a public way. Allowable paths of egress from a Group A occupancy is 30 ft. not 75 feet as denoted on the left side of this sheet. Please revise this note and denote paths of egress from Group A occupancies complying with 1028.8. T1-4.0 •Add the following note: Fire safety during construction and demolition shall comply with CFC Chapter 14. T1-5.0 Partition Plan Legend • Identify rated partitions and reference rated assembly details on Sheet TI-8.0. Clarify if there is an existing rated demising wall between the adjacent tenant, on the Partition Plan Legend and on 3/T1-8.0 details. Partition Plan Identify the rooms west of Youth Classroom 115. • It is recommended that new and/or existing fire extinguishers be located in a visible and readily available location in a common path of egress, preferably near exits. • Denote Occupant load signs in all assembly occupancies. •Classroom 129 - All doors shall be equipped with panic hardware. (Door R-10 not equipped with PH). • Denote the second required exit, equipped with panic hardware, from Family Area 128. Identify accessory use areas. CBC 508.2 Identify incidental use areas and detail compliance with CBC 508.2.5.2. i.e. Storage Room 125 • Identify Electrical and Telephone as incidental rooms use areas and detail compliance with CBC 508.2.5.2 Denote all rated assemblies with references to details. Clarify if there is an existing rated demising wall between the adjacent tenant, on the Partition Plan Legend and on 3/T1-8.0 details. • Please explain the reason for 90-minute rated exterior exit doors in Sanctuary Area 109.Not Required Partition Notes •36. Provide details of room divider, including burning characteristics, in accordance with CBC 803. To be provided on Finish Plan Tl-10. Omitted TI-5.1 Door Notes • Provide a note stating: All doors shall be openable from the egress side without the use of a key or special knowledge or special effort. Door Schedule • E-1 & N-5 - Sign is not applicable, please remove. Doors equipped with panic hardware cannot be locked on the egress side at any time. • R-5 - Door shall comply with CBC 508.2.5.2 Page 3 of 3 T1-7.1 Reflected Ceiling Plan •Reflected Ceiling Plan does not resemble Partition Plan. Please revise. Okay Denote all exit sign locations in accordance with CBC 1011.1. Not shown in several areas. Denote a direction exit sign for the second exit required from Family Area 128. Provide a directional exit sign to the second required exit to a public way. When 2 exits are required there shall not be a convergence of egress paths. CBC 1015.2.1 Reflected Ceiling Plan Legend •Add 90-minutes to battery backup for emergency means of egress light fixtures providing 1 foot-candle illumination. •Add 90-minutes to battery backup for and exit signs providing 5 foot-candle illumination. Reflected Ceiling Plan Notes • 11 & 33. Add 'upon approval of deferred system plan, under separate permit, by the AHJ '. See TS1.0 Deferred Submittals. •25. Verify projection screen does not block/disguise exit door. TI-8.1 identify details for rated assemblies. Include UL listings for rated systems, references to CBC Table 720.1 Item Number and/or ICC-ER number Tl-10 Provide Sheet T-10.0 Provided Add a note: All finish materials will comply with the requirements of CBC Chapter 8. Address T1-5.0 Partition Note 36 regarding room divider. Omitted • Provide a note stating that the burning characteristics, labels and/or California State Fire Marshal listings for finish and insulation materials will be made readily available to fire and building inspectors during field inspection. Deputy Fire Marshal has requested California State Fire Marshal listings for finish and insulation materials will be made readily available as a condition of approval for this permit. MU Mechanical Plan Check Notes • Revise notes to reference current editions of 2010 CMC and 2010 CBC Plan •Denote locations of supply ducts equipped with smoke detectors on plan. See Mechanical Plan Check Notes 8&9. No new mechanical equipment. Denote Fire/Smoke Dampers on floor plan. Clarify Mechanical Plan Check Note 10. Remove fire damper notes, not applicable to this proiect. Details • Provide details for new equipment. No new mechanical equipment. • Provide fire proofing detail and listing for penetration of fire rated assemblies. N/A Electrical Provide lighting plan showing: •Wiring to emergency means of egress light fixtures providing 1 foot-candle illumination equipped with 90- minute minimum battery pack • Exit signs providing 5 foot-candle illumination equipped with 90-minute minimum battery pack. Coordinate emergency lighfing fixtures with T1-7.1 See new comment on T1-7.1 for directional exit sign from Family Area 128 •Denote exterior lighting equipped with emergency power outside all exterior exits. CORRECTION LIST 2 Page: 1of3 BLDG. DEPT COPf Daryl K. James & Associates, Inc. Checked by: Darvl K. James 205 Co//na Terrace Date: December 16, 29II Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Richard Lund JURISDICTION: Carlsbad Fire Department PROJECT NAME: North Coast Church PROJECT ADDRESS: 2310 Camino Vida Roble 104 PROJECT DESCRIPTION: CBl 12163 19,548 sf. tenant improvement in exisfing church This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correcfion, clarification or addifional informafion before this plan check can be approved for permit issuance. INSTRiCiiSi^ ADDRESS REMAINING COMMENTS PRINTED IN BLUE FONT • Corrections or modiflcations to the plans must be clouded and provided with numbered deltas and revision dates along with a descripfive narrative of corrections addressing all comments. • Please direct any questions regarding this review to: Daryl K. James kitfire@sbcglobal.net • Corrected Plans, Response To Corrections, Following Each Comment On This Form. When Available Provide a Copy of Building Dept. (Esgil) Comments as soon as available. TO ENSURE EXPEDITED REVIEW, REVISIONS MUST BE SUBMITTED DIRECTLY TO: DARYL K. JAMES 205 COLINA TERRACE VISTA, CA 92084 COMMENTS T-S1.0 Deferred Submittals •2010 Fire Sprinkler System CFC 902.1 & NFPA 13 2010 Fire Alarm System CFC 907.1.1 & NFPA 72 Add 907.2.1.1 specific to Group A and CBC 907.2.3 specific to Group E. (See EP-3.0 comments). Clarify if Kitchen Hood & Duct, as denoted on Sheet TS1-1, will be listed under Deferred Submittals (See General Notes/Fire Safety and Prevention Notes TS-1.0 & T-S1.1 comments) Project Data •Construction Type - Specify Type ll-A or ll-B Occupancy Type - Denote all occupancy types in Suite 104. Specify accessory areas. See comments for EP- Denote adjacent occupancy types. See SP-2.0 NIC hashed area. Sheet Index Revise Sheet index to match sheets in this set. (Several) Change EX sheets to EP sheets and change TI- 5.1 to Door & Window Schedule T-10.0 and P-1, P-2 and P-3 are missing. •Sheet E0.1 is missing from this set. Provide Electrical Lighting Plan General Notes/Fire Safety and Prevention Notes TS-1.0 & T-S1.1 Delete all notes not applicable to the tenant improvement in this existinq suite, i.e. kitchen cooking equipment, elevator requirements and all other notes that reference requirements fire protection svstems and equipment. Specific to for new building structures. Notes should be limited to tenant improvements specific to this proiect. Paqe 2 of 3 EP*-3.0 &EPi.1 • Scale on Titie Block is 1/8"=1'0 yet scale on Exit Plan is 3/32" = I'O". Please clarify actual scale. • Provide furnishing layout throughout including, but not limited to sanctuary seating. Denote the occupancy classiflcation of each room or area. CBC Chapter 3. See attached IBC Code Commentary on E Occupancies in places of religious worship, from the IBC Code and Commentary Sec. 305.1. Several closely spaced classrooms with an aggregate OL >100 = Group E Occupancies. Denote the square footage, occupant load factor and occupant load of each room or area based on the function of the space. See CBC Table 1004.1.1 Column heading Function of Space. Denote accessory use areas. Revise as per previous comment. • Describe the use of Family Area 128 Denote the second required exit, equipped with panic hardware, from Family Area 128. Show path of egress and exit access travel distance from this second exit to a public way. • Show Common Paths of Egress Travel (CBC 1014.3) and Exit Access Travel Distance (CBC 1016) from all areas to a public way. Denote travel lengths and number of occupants per exit. See previous comment regarding occupant loads. Please denote compliance with CBC 1028 sections applicable to means of egress in an assembly occupancy including, seating, but not limited to, required width of egress to a public way. TI-4.0 •Add the following note: Fire safety during construction and demolition shall comply with CFC Chapter 14. TI-5.0 Partition Plan Legend Identify rated partitions and reference rated assembly details on Sheet TI-8.0. Clarify if there is an existing rated demising wall between the adjacent tenant, on the Partition Plan Legend and on 3/T1-8.0 details. Partition Plan Identify the rooms west of Youth Classroom 115. • It is recommended that new and/or existing tire extinguishers be located in a visible and readily available location in a common path of egress, preferably near exits. • Denote Occupant load signs in all assembly occupancies. • Classroom 129 - All doors shall be equipped with panic hardware. (Door R-10 not equipped with PH). Denote the second required exit, equipped with panic hardware, from Family Area 128. Identify accessory use areas. CBC 508.2 Identify incidental use areas and detail compliance with CBC 508.2.5.2. i.e. Storage Room 125 Identify Electncal and Telephone as incidental rooms use areas and detail compliance with CBC 508.2.5.2 Denote all rated assemblies with references to details. Clarify if there is an existing rated demising wall between the adjacent tenant, on the Partition Plan Legend and on 3/T1-8.0 details. • Please explain the reason for 90-minute rated exterior exit doors in Sanctuary Area 109.Not Required Partition Notes • 36. Provide details of room divider, including burning characteristics, in accordance with CBC 803. To be provided on Finish Plan Tl-10. Omitted TI-5.1 Door Notes • Provide a note stating: All doors shall be openable from the egress side without the use of a key or special knowledge or special effort. Door Schedule • E-1 & N-5 - Sign is not applicable, please remove. Doors equipped with panic hardware cannot be locked on the egress side at any time. • R-5 - Door shall comply with CBC 508.2.5.2 TI-7.1 Reflected Ceiling Plan • Reflected Ceiling Plan does not resemble Partition Plan. Please revise. Okay Denote all exit sign locations in accordance with CBC 1011.1. Not shown in several areas. Denote a direction exit sign for the second exit required from Family Area 128. Page 3 of 3 ReiPlecled Ceiling Plan Legend •Add 90-minutes to battery backup for emergency means of egress light fixtures providing 1 foot-candle illumination. •Add 90-minutes to battery backup for and exit signs providing 5 foot-candle illumination. Reflected Ceiling Plan Notes • 11 & 33. Add 'upon approval of deferred system plan, under separate permit, by the AHJ '. See TS1.0 Deferred Submittals. •25. Verify projection screen does not block/disguise exit door. TI-8.0 • Identify details for rated assemblies. Include UL listings for rated systems, references to CBC Table 720.1 Item Number and/or ICC-ER number. No rated assemblies Tl-10 Provide Sheet T-10.0 Add a note: All finish materials will comply with the requirements of CBC Chapter 8. Address T1-5.0 Partition Note 36 regarding room divider. Omitted Provide a note stating that the burning characteristics, labels and/or California State Fire Marshal listings for finish and insulation materials will be made readily available to fire and building inspectors during field inspection. MLl Mechanical Plan Check Notes • Revise notes to reference current editions of 2010 CMC and 2010 CBC Plan • Denote locafions of supply ducts equipped with smoke detectors on plan. See Mechanical Plan Check Notes 8&9. No new mechanical equipment. Denote Fire/Smoke Dampers on floor plan. Clarify Mechanical Plan Check Note 10. Details • Provide details for new equipment. No new mechanical equipment. • Provide fire proofing detail and listing for penetrafion of fire rated assemblies. N/A Electrical Provide lighting plan showing: •Wiring to emergency means of egress light fixtures providing 1 foot-candle illuminafion equipped with 90- minute minimum battery pack • Exit signs providing 5 foot-candle illumination equipped with 90-minute minimum battery pack. Coordinate enriergency lighting fixtures with TI-7.1 New comment on TI-7.1 for directional exit sign from Family Area 128 • Denote exterior lighting equipped with emergency power outside all exterior exits. BEST COPY USE ANP OCCUPANCY CLASSIFICATION p !>.' .. •:•• :ad of less than 50 are classified in §tmi • - • Section 305.1). When lecture facilities . .Ls :i.e., occupant load of 50 or more) are Dewto « :ne same building where classrooms |p» .s • . -.It load less than 50 are found, the IpKi^ , • • 2d occupancy (Groups A-3 and B) and ^l|»0#<; • orovisions of Section 508.3. » • -lies generally consist of a group of ^ .vhere various medical services can be '•--e clinics are assumed to function dur- ii r - ness hours (i.e., less than 24 hours) " - are generally ambulatory and capable • - on. Admittedly, some patients may be "sapacitated due to anesthesia or re- .«. --s however, a building that is used for -"etc or nonlife-saving surgeries would ' : as Group B. The Group B occupancy • :- does not assume surgical procedures • 3!ve in-house recovery times, potential com- :al/surgical procedures or overnight stays, jsed for trauma centers, urgent care or . room services would more appropriately • ed as Group 1-2. Buildings used as sleep .. d also be classified as Group B since these not typical dwelling or sleeping units where - the occupants are assumed to be capable --; -.'ation and the occupants are not living in environment. SECTION 305 EDUCATIONAL GROUP E £ S,*n»c *'>iiiu)l (iroup E. Educational Group E occupancy WE" . . ; hers, the use of a building or structure, or a n. or more persons at any one time for edu- >#««- • . - -.Iirough the 12th grade. Religious educa- it. v,. . . iigious auditoriums, which are accessory to * V . - .\ oiship in accordance with Section 508.3.1 te - • • load.s of less than 100, shall be classified as M -jn« • 'e safety in this occupancy vary with the si*«^-«.' .•' the facilities and also with the ages of * » -.. t i-rs In general, children require more safe- - .:o older, more mature persons. •''•'vr. i^:' - identifies the criteria for classification of - G'oup E. The two fundamental character- fei ,f •; 3-;-;p E facility are as follows: •'s: Ity is occupied by more than five per- •si t-* -eluding the instructor); and w : .-2ose ofthe facility is for educating per- - V r.: the 12th-grade level and below, but not t » •<.'. ~3 more than five occupants 2V2 years of #-* ess. es used for the education of persons ;:n-grade level are not included in Group : !ies are occupied by adults who are not 'equire special supervision, direction or instruction in a fire or other emergency. By the same measure, however, they also are not closely super- vised; therefore, class'rooms and laboratories located in colleges, universities and academies for students above the 12th grade are classified in Group B, be- cause the occupancy characteristics and potential hazards to life safety present in these facilities more nearly resemble those of a business occupancy than educational occupancy. Similarly, lecture halls for stu- dents above the 12th grade with an occupant load of 50 or more are classified in Group A-3 (see Section 303.1). It is common for a school to also have gymnasiums (Group A-3), auditoriums (Group A-1), libraries (Group A-3), offices (Group B) and storage rooms (Group S-1). When this occurs, the building is a mixed occupancy and is subject to the provisions of Section 508.3. In accordance with Section 508.3.1, Exception 2, assembly spaces, such as the gymnasium, audito- rium, library and cafeteria, do not have to be consid- ered separate occupancies if used for school pur- poses only and is limited to school occupants (see commentary, Section 508.3.1). Places of religious worship, religious educational rooms and religious auditoriums are often provided in the same building complex. These religious and edu- cational rooms and religious auditoriums are not to be considered separate occupancies (i.e., Group E) as long as the occupant load in these spaces is no greater than 99 people. Similar to accessory assem- bly spaces, the intent of the occupant load threshold for religious educational rooms and religious auditori- ums is not to create several rooms closely spaced to- gether, each with an occupant load of less than 100. In this case, these rooms would be classified as Group E and the building would be considered a mixed occu- pancy and subject to the provisions of Section 508.3. 305.2 Day care. The use of a building or structure, or portion thereof, for educational, supervision or personal care services for more than five children older than 2'/, years of age, shall be classified as a Group E occupancy. • Day care centers are a special problem since they are generally occupied by preschool children who are less capable of responding to an emergency. The hazards found in a day care center are far greater than in nor- mal educational facilities, not so much because ofthe occupant or fuel load, but because of the inability of the occupants to respond. Day care occupancies include facilities intended to be used for the care and supervision of more than five children for a period of less than 24 hours per day and that do not contain at any time more than five children who are 2V2 years of age or less. Facilities that provide care for more than five occupants greater than the 12th grade are to be classified as adult care facilities (Group 1-4, Section 308.5.1) or Group A-3. Children 2V2 years of age or less usually are not able to recognize an emergency situation, may not re- ITIONAL BUILPING COPE® COMMENTARY CORRECTION Ll ^LDG. DEPT COPY'^-^^ Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Checked by: Daryl K. James Date: October 14. 2011 APPLICANT: Richard Lund JURISDICTION: Carlsbad Fire Department PROJECT NAME: North Coast Church PROJECT ADDRESS: 2310 Camino Vida Roble 104 PROJECT DESCRIPTION: CB112163 19,548 sf. tenant improvement in exisfing church This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correcfion, clarification or addifional information before this plan check can be approved for permit issuance. mmmmmm • Correcfions or modifications to the plans must be clouded and provided with numbered deltas and revision dates along with a descriptive narrative of corrections addressing all comments. • Please direct any questions regarding this review to: Daryl K. James kitfire@sbcglobal.net • Corrected Plans, Response To Corrections, Following Each Comment On This Form. When Available Provide a Copy of Building Dept. (Esgil) Comments as soon as available. TO ENSURE EXPEDITED REVIEW, REVISIONS MUST BE SUBMITTED DIRECTLY TO: DARYL K. JAMES 205 COLINA TERRACE VISTA,CA 92084 COMMENTS TS1.0 Deferred Submittals 2010 Fire Sprinkler System CFC 902.1 & NFPA 13 2010 Fire Alarm System CFC 907.1.1 & NFPA 72 Project Data Construction Type - Specify Type ll-A or ll-B Occupancy Type - Denote all occupancy types in Suite 104. Specify accessory areas. See comments for EP-3.0. Denote adjacent occupancy types. Sheet Index Revise Sheet index to match sheets in this set (Several) Sheet E0.1 is missing from this set. Provide Electrical Lighfing Plan General Notes/Fire Safety and Prevention Notes Delete all notes not applicable to the tenant improvement in this existinq suite, i.e. Reference to A2 Occupancy, NFPA 13D, Encinitas F.D., kitchen cooking equipment, elevator requirements and all other notes applicable to new buildings and fire protection systems and equipment. EP-3.0 Scale on Tifie Block is 1/8"=1'0 yet scale on Exit Plan is 3/32" = I'O". Please clarify actual scale. Provide furnishing layout throughout including, but not limited to sanctuary seafing. Denote the occupancy classification of each room or area. CBC Chapter 3. Denote the occupant load factor and occupant load of each room or area based on the actual use. CBC Table 1004.1. Describe the use of family Area 128 , Page 2 of 3 EP-3.0 (Continued) Denote accessory use areas. Show Common Paths of Egress Travel (CBC 1014.3) and Exit Access Travel Distance (CBC 1016) from all areas to a public way. Denote travel lengths and number of occupants per exit. Please denote compliance with CBC 1025 sections applicable to means of egress in an assembly occupancy including, seafing, but not limited to, required width of egress to a public way. T1^.0 Add the following note: Fire safety during construction and demolition shall comply with CFC Chapter 14. T1-5.0 Partition Plan Legend Identify rated partitions and reference rated assembly details on Sheet TI-8.0 Partition Plan Identify the rooms west of Youth Classroom 115. It is recommended that new and/or exisfing fire extinguishers be located in a visible and readily available location in a common path of egress, preferably near exits. Denote Occupant load signs in all assembly occupancies. Classroom 129 - All doors shall be equipped with panic hardware. (Door R-10 not equipped with PH). Identify accessory use areas. CBC 508.2 Identity incidental use areas and detail compliance with CBC 508.2.5.2. i.e. Storage Room 125 Denote all rated assemblies with references to details. Please explain the reason for 90-minute rated exterior exit doors in Sanctuary Area 109. Partition Notes 36. Provide details of room divider, including burning characteristics, in accordance with CBC 803. To be provided on Finish Plan Tl-10. Ti-5.1 Door Notes Provide a note stafing: All doors shall be openable from the egress side without the use of a key or special knowledge or special effort. Door Schedule E-1 & N-5 - Sign is not applicable, please remove. Doors equipped with panic hardware cannot be locked on the egress side at any fime. R-5 - Door shall comply with CBC 508.2.5.2 T1-7.1 Reflected Ceiling Plan Reflected Ceiling Plan does not resemble Partition Plan. Please revise. Denote all exit sign locations in accordance with CBC 1011.1. Not shown in several areas. Reflected Ceiling Plan Legend Add 90-minutes to battery backup for emergency means of egress light fixtures providing 1 foot-candle illumination. Add 90-minutes to battery backup for and exit signs providing 5 foot-candle illumination. Reflected Ceiling Plan Notes 11 & 33. Add 'upon approval of deferred system plan, under separate permit, by the AHJ '. See TS1.0 Deferred Submittals. 25. Verify projection screen does not block/disguise exit door. TI-8.0 Identify details for rated assemblies. Include UL lisfings for rated systems, references to CBC Table 720.1 Item Number and/or ICC-ER number. Ti-10 Add a note: All finish materials will comply with the requirements of CBC Chapter 8. Address TI-5.0 Partition Note 36 regarding room divider. Provide a note stafing that the burning characterisfics, labels and/or California State Fire Marshal lisfings for finish and insulation materials will be made readily available to fire and building inspectors during field inspecfion. - ^ Page 3 of 3 Ml.l Mechanical Plan Check Notes Revise notes to reference current edifions of 2010 CMC and 2010 CBC Plan Denote locations of supply ducts equipped with smoke detectors on plan. See Mechanical Plan Check Notes 8&9. Denote Fire/Smoke Dampers on floor plan. See Mechanical Plan Check Notes 8&9. Details Provide details for new equipment. Provide fire proofing detail and listing for penetrafion of fire rated assemblies. Electrical Provide lighfing plan showing: Wiring to emergency means of egress light fixtures providing 1 foot-candle illuminafion equipped with 90-minute minimum battery pack Exit signs providing 5 foot-candle illuminafion equipped with 90-minute minimum battery pack. Coordinate emergency lighfing fixtures with TI-7.1 Denote exterior lighfing equipped with emergency power outside all exterior exits. ^ CITY CARLSBAD O F PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Project Address: Permit No.: )\-2»H#5 Information provided below refers to worb being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixture^, traps, or floor drains "7 New building sewer line? Ves No ^ Number of new roof drains? O Install/alter water line? >lti Number of new water heaters? I Number of new, relocated or replaced gas outlets? b Number of new hose bibs? 6 , Tenant Improvement/Remodels: ' |\ 6 * 1k1ki*Ai J \ Number of Panels Onvolved in this project) _^— Amps per panel (involved in this project) i. A - | j^g- A -j Remodel only - (relocate/add outlets/switches) Ves A No New Construction: Number of new panels or subpanels? O Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? ^ New or relocated duct worb? Ves X No Number of new fireplaces? ^ Number of new exhaust fans? ^ Relocate/install vent? ytM Number of new exhaust hoods? ^ Number of new boilers or compressors? Number of HP O B-18 Page 1 of 1 Rev. 03/09 INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Date^^f>J^/^ f Business Name A^^y^ <^g^>y A ^A.^'^^^^ Street Address Z"?/^ C^/^ Ye^^i^ Email Address ^3^/1.^^^^ ^.^^/ 7^ .QP*'^ PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining/Milling Painting/Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuei Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical iVlanufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphafing) Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film / X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap / Detergent Manufacturing Industrial Laundry Waste Treatment / Storage SIC Code(s) (if known): Brief description of business activities (Production / Manufacturing Operations):_ - ^-f*^ rc Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal/day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: A/A- Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes ^/l^ if yes, when: Site Contact ^J^rf ^^nt^ Title Signature_ 17' Phone No ENCINA WASTEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760)438-3941 F/0<; (760)476-9852 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / / Business Name ^ / / y A/^r^/^ (^i/^-f^ C^c^f^if^ 1 j Business Contact Telephone # Project Address J ^^^^ V//!f^>f ^ City - yi^^ J Sta.l.'S Zip Code APN# Mailing Address ^ City State Zip Code Plan File# Project Contact ^*i^-i-*t^ ^..^^ ^ Telephone # { \ The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTIVIENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): Occupancy Rating: 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTIVIENT OF ENVIRONIVIENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HIVIDl: If the answer to anv of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. cZi^/'^':** y FEES ARE REQUIRED. Project Completion Date: ^^7 f f Expected Date of Occupancy: <^'^*^f»^-'-7 (for new construction or remodeling projects) • CalARP Exempt I Date Initials • CalARP Required / Date Initials • CalARP Complete / Date Initials YES NO 1. D ^ Is your business listed on the reverse side of this form? (checl< all that apply). 2. • Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3. • 1^ Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? 4. • IS Will your business use an existing or install an underground storage tanl<? 5. • H Will your business store or handle Regulated Substances (CalARP)? 6. • 0- Will your business use or install a Hazardous Waste Tanl< System (Title 22, Article 10)? 7. • ^ Will your business store petroleum in tanl^s or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demoiition or renovation of residential structures of four units or less. Contact the APCD for more information. YES NO 1 • • H Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.orq/info;'facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). 2. '.B" Bg^(ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http://www,cde.ca.gov/re/sd/ for public and private schools or contact the appropriate school district). 3. • (3^ Has a surv/ey been performed to determine the presence of Asbestos Containing Materials? 4. • ffl" Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? 5. • H' Will there be demolition involving the removal of a load supporting structural member? Briefly describe proposed project: Name of Owner or Authorized Agent 3 herein are true and con-ect. Signature of Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD *A stamp in this box onlv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) County of San Diego - DEH - Hazardous Matenals Division O 00 * Mi w ro CO o 3 o > O CD ST n 3 a a O c • 5