Loading...
HomeMy WebLinkAbout2320 HOSP WAY; ; 74-1062; Permit0 BUILDING PERMIT APPLICATION City of CARLSBAD, CAl-tFORNIA 92008 Applicantto complete numbered spaces only. Phone 7 29-1181 Permit No. JOB AODR £5S ASSESSOR S PARCEL NUMBER l 1...01 NO --------------.--,,.-L-K------r--T-A-A-,-CT::------------------------t a=o~K~~P~A~G-E~=-P=-c-A-:R-. --I tOscc ATTACHr.o SHtCTJ 1 ~~;~~- OWNt.11' MAIL AOOAE.!55 2,. PHONE 2 CITY CON TRAC TO lit 3 4 [.NGINElR MA.IL. ADDRESS PHONE LICC.1'il.SE NO. 5 6 7 8 Class of work: 0 NEW 1:l ADDITION 0 ALTERATION 0 REPAIR 0 MOVE 0 REMOVE 9 Describe work: 10 Change of use from Change of use to 11 Valuation of work: $ PLAN CHECK FEE$ 1-S_P_E_C_I_A_L_C_O_N_D_I_T_I_O_N_S_: ________________ --'---f Type of Const 1-----------------------------~ Size of Bldg. (Total) Sq. Ft 1-------------------------=----::;_.._ _ _.. Fire Zone APPLICATION ACCEPTED BY PLANS CHECKED BY DATE No. of Dwelling Units Occupancy MICRo/FILM FEE Group No. o f Max Stories 0cc Load use Fire Sprinklers Zone Required 0Yes OFFSTREET PAF\KING SPACES: No. No. Covered Sq. Ft. Open O No NOTICE Special Approvals Required Received Not Required SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB- ING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN120DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE ANO CORREC,-. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TD VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. !IC.NAT IU. or OWH[ft ,,. OWNER IJUILOC") DAT( PLANNING DEPT. HEALTH DEPT. FIRE DEPT. SOIL REPORT OTHER (Specify) ENGINEERING DEPT. WATER DEPT. WHEN PROPERLY VALIDATED (IN THIS SPACEI THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK, M.O, CASH PERMIT VALIDATION CK. INSPECTOR M.O. CASH t) ~ ( ' .. BUILDING PERMIT APPLICATION City of CARLSBAD, CALIFORNIA 92008 Applicantto complete numbered spaces only. Phone 729-1181 Permit No. JOB AOOR t~ LOT NO. Im V 20WN~fa<' CONTRACTOR 3 AACHITECT OPII DESIGNER 4 C.NGINEC.;,.-, 5 • (),S.. .. . .~ COMPENSATION INS, CARRIER 6 use OF BUILDING 7 8 Class of work: □N EW 0 ADDITION 9 Describe work: 10 Change of use from Change of use to lTaACT 7 MAIL A00AE5S I ·- MAIL A0OA£SS MAIL AOOAESS -MAIL AOORtSS V . ---~ .,. . MAIL AOOAESS 0 ALTERATION 0 REPAIR .P - ASSESSOR'S PARCEL NUMBER tOsti: ATTACHED sHtCTI BvOK PAGE I 21 P PHONE LICENSE NO, STATE PMONE: LICENSE NO. PHONE LIC£t,,jS£ NO. ff ' BRAN CH 0 MOVE 0 REMOVE PAR, CITY 11 Valuation of work : $ I PERMIT FEE $ ---PLAN CHECK FEE s 1-5'-P_E_C_I_A_L_C_O_N_O_I_T_I_O_N_S_: __________________ ----I Type of Const. 1---------------------------------1 Size of Bldg. (Total) SQ. Ft. 1------------,.-----------...-----------t Fire APPLICATION ACCEPTED BY PLANS CHECKED BY APPROVED FOR ISSUANCE BY Zone DATE NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB· ING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED 15 NOT COMMENCED WITHIN 120DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. StGNATUllltt 0,-CONTRACTO"-Oft A.UTHONJZtO AGENT I• - (DATE) (. /. , 91t.N•T111111r o, OWH[R IP' OWNUl IIUILDtlllt) fOATE) No. of Oweillng Units Special Approvals PLANNING DEPT. HEAL TH DEPT. FIRE DEPT SOIL REPORT OTHER (Specify) ENGINEERING DEPT. WATER DEPT, Occupancy Group No. of Stories Use Zone ) - MICRO FILM FEE Max. 0cc. Load Fire SprlnKlers Required DYes ONo OFFSTREET PARKING SPACES: No. JNo. Covered Sq. Ft. Open Required Received Not Required WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION cK. M.o. CASH PERMIT VALIDATION cK. M.O. CASH INSPECTOR .. INSPECTION RECORD DATE REMARKS INSPECTOR FOUNDATIONS: SET BACK TRENCH MASONRY FINAL i. BRIAN SMITH, ENGINEERS, INC. CONSULTING CIV!L ENGINEERS 2656 STATE STREET • CARLSBAD, CALIFORNIA 92008 • PHONE 729-8981 , March 18, 1976 Kamar Construction Co. 325 Elm Avenue Carlsbad, CA 92008 Re: J. N. 4230 Subject: Swirr.ming Pool Inspection at Grove Apartments Recreation Center Gentlemen: In accordance with the request of Jerry Rombotis of your company, I inspected the subject swimming pool on March 17, 1976. The purpose of this inspection was to make· recommendations for the repair of the pool. The inspection revealed several cracks in the bottom of the pool, some of which had evidently been previously patched. Seven concrete core holes were observed in the bottom of the pool. Standing water was found in the core holes near the deep end of the pool. Hand sam- ples of the soils underlying the pool obtained through the cor·e holes were found to be saturated and clayey as determined by observation and feel. No tests were performed on the soils. I could not determine from my observation if the pool is con- structed for expansive soil conditions. However, it should be poss- ible to determine if the pool is constructed for expansive soil con- ditions from the thickness of_the core samples. A review of the "Soil and Geological Investigation for the Proposed Hosp Grove Apartments" dated August 25, 1972 and "Final Report of Engineering Observations and Compaction Testing, Grove Apart-· ments" dated March 1, 1973 prepared by Woodward-Gizienski & Associates indicates water seepage at various locations on the site. This fact was confirmed by Jerry Rombotis from his observations during grading. Due to the high degree of saturation of the scils underlying the pool and possible groundwater seepage under the pool, it is recorr.men- ded a filter drain be installed from the deep end of the pool. The recommended design for the filter drain is attached. It is recommended the bottom of the pool be overlaid with 5 inches of reinforced concrete. A typical section for this recommen- dation is attached. Sincerely, BRIAN SMITH ENGINEER i✓. /4i-- E. Brian Smith RECEIVED .. MAR 19 1976 CITY OF CARLSBAD Building Department ~~/4 r r i i i