Loading...
HomeMy WebLinkAbout2327 CARINGA WAY; 5; 1972; Permit5.14 UNITS PROVIDED ^^^^™^^w^w> OF COVERAcw*»^w FRONT SETBACK .ALLOWED..PRKG. SPACES PROVIDED. I^P Al I nWFH tgf) IP BLDG. HEIGHT_t)X=^— ALLOWED ^ SIDE YARD iOX- REAR YARD Ov—- INTRUSION! ENVIRONMENTAL PROTECTION .REQTS. ADDITIONAL COMMENTS. LANDSCAPE PLAN ISSUE PERMIT. ENGINEERING DEPARTMENT R.Q.W. fa. '1""» «." ^•f^fca .INDUSTRIAL WASTE./// IMPROVEMENTS..SEWER CONNECTION. DRIVEWAY LOCATIONS.<•* X '.-;'.GRADING HRAINARF LEGAL DESCRIPTION. ADDITIONAL COMMENTS, ISSUE PERMIT .DATE..OCCUPANCY DATE FIRE DEPARTMENT SPRINKLING SYSTEM. FIRE PROTECTION EQUIPMENT. EXITS ALARMS -rt- FIRE HYDRANTS. ADDITIONAL COMMENTS. ISSUE PERMI LOCATION. nATF -"? 3 \JE PERMIT..DATE..OCCUPANCY. .DATE. v>J c vreR DEPARTMENT M-W D CARLSRAD OLIVENHAIN ADDITIONAL HOMMFNTS SAN MARCOS .DATE. TO PLANNING SENT TO ENG. DEPT. .rlNED TO BLDG.RETURNED TO BLDO. DFPT 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008 Building Dept. TELEPHONE: (714) 729-1181 Citj> of Cartebab April 14, 1975 URBANETICS FINANCIAL CORPORATION The plan check for this set of plans is void and revised plans with plan check fee will have to be sub- mitted if project is to be developed. If you have any further questions contact the Building Dept. 729-1181 Ext. 47 Thank you Jreen Checker BENTON ENGINEERING, INC. APPLIED SOIL MECHANICS — FOUNDATIONS 6717 CONVOY COURT SAN DIEGO, CALIFORNIA 02 Ml PHILIP HENKINO BENTON .. «- , rt_«PK...O.NT . C.V.L .„<,,„.«, • May 30, 1973 =68.1SBB Urbanetics Financial Corporation 8601 Wilshire Boulevard Beverly Hills, California 90221 Subject: Project No. 73-3-28D, Supplement Recommendations for Column Footings Lots 229 and 230 La Costa Valley Unit No. 5 Carlsbad, California Gentlemen: We have been requested by Paul Koshi & Associates to forward our recommendations relative to the feasibility of using isolated column footings at the above sites. In our report of the testing and inspecting of additional compacted filled ground placed on these. sites, we recommended that the use of isolated interior piers be avoided. However, this should not be construed as applying to interior columns. Such interior columns may be used, provided the column footings comply with our recommendations for continuous footings, and further provided that: a) Columns and/or column footings are structurally separated from concrete slabs, and b) Adequate steps are taken to prevent changes in the moisture content of the soils supporting the column footings. Respectfully submitted, BENTON ENGINEERING, INC. By M, V. Pothier, Civil Engineer ' Distr: (1) Addressee (2) Paul Koshi & Associates Attention: Mr. James Lai MVP/ew BENTON ENGINEERING, INC. TlPPLIED SOIL MECHANICS FOUNDATIONS 6717 CONVOY COURT f ->N DIEGO, CALIFORNIA PHILIP HENKINQ BENTON A . I r>A t n-TO PRESIDENT . CIVIL ENGINEER April £<J, I T/J TELEPHONE I 71 4 ) 565-19S5 Urbonetics Financial Corporation 8601 Wilshtre Boulevard Beverly Hills, Calffornfa 90221 Subject: Project No. 73-3-28D Report on Compacted Filled Ground Lots 229 and 230 La Costa Valley Unit No. 5 Carlsbad, California Gentlemen: This is to report the results of tests and observations made in order to inspect the compaction of additional filled ground placed on portions of Lots 229 and 230 of La Costa Valley Unit No. 5 in Carlsbad, California. The fill was placed on March 29, 1973 and varied in depth to a maximum of approximately two feet. Compacted filled ground had previously been placed on these lots during the major grading of this subdivision conducted between May 13 and October 7, 1970. The results of tests and observations made in order to inspect the compaction of this previously placed filled ground are presented In our report dated November 4, 1970. The approximate area and depths of filled ground placed under our inspection in accordance with the approved specifications on March 29, 1973 are shown on the attached Drawing No. 1, entitled, "Location of Compacted Filled Ground. " The original grading plan used for the placement of filled ground on these subject lots was prepared by Rick Engineering. The approximate locations at which the tests were taken are shown on Drawing No. 1 and the final test results are presented on page 3, under the "Table of Test Results. " The laboratory determinations of the maximum dry densities and optimum moisture contents of the major fill materials are presented on page 3, under "Laboratory Test Results." The existing clay fill soils, described at the bottom of page 2 of our report dated November 4, 1970, were removed and the filled ground was placed on existing compacted fill soils Inspected and tested by Benton Engineering, Inc. or on suitable firm natural soils. Expansive sllty clay and clay soils were placed in the filled ground areas and It is recommended that the following special design and precautions be taken to reduce the adverse effects these soils may have on buildings constructed on these lots: 1. Avoid the use of isolated interior piers. Use continuous interconnected reinforced footings throughout, and place these at a minimum depthj?f 24^ inches below the lowest adjacent exterior final ground surface. Project No. 73-3-28D -2- Apr.119, 1973 La Costa Valley Unit No. 5 2. Reinforce and Interconnect continuously with: steel bars all Interior and exterior Footings with one *5 bar at 3 Inches above the bottom of the footings and one ^5 bar placed 1 1/2 Inches below the top of the stems of the footings. 3. Raised wooden floors that span between continuous footings are best/ or use concrete slabs reinforced with at least 6x6 10/10 welded wire fabric. AlSThTmum 6F"4 Tnches of criisnea^ be placed beneath all concrete slabs and be covered with a moisture barrier. This should then be covered with 2 inches of sand below concrete slabs. 4. Separate garage slabs from perimeter footings by a 1/2 inch thickness of construction felt or equivalent, to allow independent movement of garage 4^ slabs relative to perimeter footings. Assure complete separation by extend- ing the felt over the full depth of the front thickened edge of the garage slab. Also/ cut off the garage door stops at least 1/2 inch above the slab. 5. Provide positive drainage away from all perimeter footings with a vertical fall of at least 5 inches in a horizontal distance of 5 feet outside the house walls. Respectfully submitted/ BENTON ENGINEERING/ INC. By R. C. Remer Reviewed by „ / " \ Philip H. Benton/ Civil Engineer D istr: (2) Addressee (2) Maltz Altrnan Associates/ Architects (2) City of Carlsbad Department of Building Inspection Attention: Mr. Ray Green BENTON ENGINEERING. INC. Project No. 73-3-28D La Costa Valley Unit No. 5 Test No. 1 2 3 4 5 6 Approx- imate Location Lot No. 229 230 230 230 229 229 -3- TABLE OF TEST RESULTS April 19, 1973 Depth of Fill at Test in Feet 40 41 40 40 39 40 LABORATORY Field Moisture % dry wt 19.1 20.2 15.8 13.3 11.3 14.9 TEST RESULTS Soil Type Light olive, silty clay with siltstone Light olive-gray silty fine to medium sand Light gray clay Gray-brown slightly clayey fine to medium sand Dry Density Ib/cu ft 105.3 101.1 116.6 121.2 113.8 100.5 Maximum Dry Density Ib/cu ft 117.0 110.7 127.2 127.2 121.8 110.7 Percent Compaction 90.0 91.3 91.0 95, 93, 90.7 Dry Density Ib/cu ft 117.0 121.8 110.7 127.2 Optimum Mois- ture Content % dry wt 13.7 11.6 14.1 8.8 BENTON ENGINEERING. INC. - Indicates Approximate Location Of Compacted Filled Ground Placed On 3-29-73. - Indicates Approximate Location Of Field Density Test Date: 4-77-73 Drawing: RW Scale:!" = 80 LOCATION OF COMPACTED FILLED GROUND LOTS 229 AND 230 LA COSTA VALLEY UNIT NO. 5 CARLSBAD CALIFORNIA PROJECT NO. 73-3-28D BENTON ENGINEERING, INC. DRAWING NO. 1 BENTON ENGINEERING. INC. APPLIED SOIL MECHANICS FOUNDATIONS 6741 EL CAJON BOULEVARD SAN DIEGO. CALIFORNIA 921 IS PHILIP HENKING BENTON . i/ 10*70 SAN DlECO: 583-5S54 PRESIDENT . CIVIL ENGINES'- JdnUClry IO, \T/\J LA MESA: A69-56S4 La Costa Land Company Route 1, Box 2550 Encinitas, California Subject: Project No. 69-11-14BC Preliminary Soils Investigation La Costa Valley Unit No. 5 Northeast of Alicante Road South of Alga Road San Diego County, California Gentlemen: CONCLUSIONS It 's concluded from the field investigation and laboratory test results that: 1 . The firm to very firm natural soils are suitable for support of the proposed fills and residential structures. However, expansive clay soils may occur near fhe proposed finished grade In some of the areas and specially designed footings and slabs are recommended where these expansive soils are allowed to remain in place at depths of less than 3 feet below me final grade. 2 . It is recommended that the deposits of soft clay soils near the surface be removed by excavating horizontal benches in on the firm underlying natural ground and placed in layers arid compacted during grading . It is concluded from the resulfs of the laboratory tests that the nutura! soils suaS as those found below 2 .0 feet in Boring 2 have a safe bearing capacity of 2300 pounds per square foot for one foot wide continuous footings placed at a depth of 10 inches below the adjacent natural grade on firm undisturbed natural soil . The settlement of a one foot wide continuous footing loaded fo 2300 pounds per lineal foot and founded on suitable undisturbed natural soils as described above is estimated to be on the order of 1/8 inch . 3. The results of the laboratory expansion tests indicate that the silty clay and sandy clay soils encountered on this unit would be considered as "exports'.-e" type soils. VVriere these "expansive" soils are allowed to remain within me upper 3 feet below finished grade, then it is recommended that footings and slabs be specially designed. The required special design will be dependent upon ?he degree of expansion potential of fhe soil, the thickness of rhe layer, and the location of the expansive layer with respect to the footings or slabs. The lots requirtrtg specially designed footings and slabs will be listed upon rhe completion of grading . Project No. 69-11- La Costa Valley Un^f No. 5 -2-January 16, 1970 4. All of the soils may be satisfactorily compacted in the fill areas and, when com- pacted to at least 90 percent of maximum dry density, have a safe bearing capacity of 2500 pounds per square foot for one foot wide footings placed at a depth of 10 inches below the compacted ground surface. The settlement of a one foot wide continuous footing placed on fill soils uniformly compacted to 90 percent of maximum dry density is estimated to be less than 1/8 inch . Recommendations for the placement of filfed ground are presented in the attached Appendix AA, entitled "Standard Specifications for Placement of Compacted Filled Ground." 5 . It is concluded from the test data that the proposed cuts may be safely excavated on a slope ratio of 1 1/2 horizontal to 1 vertical to a maximum height of 55 feet with a 6 feet wide bench at 27 feet vertically from the top of slope. The fill soils, when uniformly compacted to at least 90 percent of maximum dry density in accordance with the approved specifications, will be stable for heights up to 55 feet when constructed on a 1 1/2 horizontal to 1 vertical or flatter slope with a 6 feet wide bench at 27 feet vertically from the top of slope. The slope stability analysis for the cut and fill slopes is presented on Drawing No. 1 1 . The above conclusions includ* a seismic factor of 0. 1 g and a factor of safety of at least 1 .5 and assume that suitable erosionc! control and proper drainage will b« provided to prevent surface water from running over the top of exposed slopes . These conclusions also apply to the proposed cut bank along Alicante Road between La Costa Valley Unit No. 5 and its inter- section with Alga Road. 6. It is recommended tf»ar the dd existing fills and soft alluvium forming the old reservoir at the easterly end of the project be removed and recompacted in accordance with Appendix AA attached hereto prior to placing additional filled ground over them. If any soil types ore encountered during the grading operation that were not tested In this invest- igation, additional laboratory tests will be conducted in order to determine their physical charact eristics, and supplemental reports and recommendations will automatically become a part of the specifications. The data presented on the attached page* are a part of this report. Respectfully submitted, BENTON ENGINEERING, INC. By' William G . Catlin, Civil Engineer --"7 Reviewed by Philip H . Ben ton, Civil Engineer Oisrr: (4) Addressee ancho Lc ick Engineering Company (2) Rancho La Costa, Inc. Attention: Mr. Burton L. KramerIn Rick - - - - Project No. 69-11- 14BQ' -3- f January 16, 1970 .la'Costa Valley Unit No. d ' DISCUSSION A preliminary soils investigation has been completed on the proposed La Costa Valley Unit No. 5 located northeast of Alicante Road and south of Alga Road in Section 25 and 36 TJ2S R4W SBB & M in San Diego County, California. The objectives of the investigation were to determine the existing soil conditions and to provide information for design of safe and econ- omical slopes and foundations and to comply with the requirements of the loan guarantee agencies and the governmental agencies having jurisdiction. In order to accomplish these objectives, four borings were drilled, undisturbed and loose bag samples were obtained, and laboratory tests were performed on these samples. The general topography of the area may be described as moderately to steeply sloping. The natural drainage is from the higher norlhcentral portion of the area to the southeast, south, and southwest. Future drainage will be into streets and storm drains. Accordirg to ihe "Soil Map" prepared by the U. S. Department of Agriculture, the upper soils in the area are described as Las Posas loamy fine sand, and Diablo clay. Las Posas loamy fine sand is indicated as 0.5 foot of friable stony fine sandy loam, 1.0 foot of slightly compact cloddy stony fine sandy loam, 1.0 to 2 .0 feet.of moderately compact stony fine sandy loam with bedrock below. Diablo day is indicated as 0.5 to 1.0 foot of cloddy clay, 1.5 to 3.0 feat of cloddy moderately compact clay wirh bedrock below. The soils encountered in the exploration borings were primarily silty clays, sandy clays, and some clayey sands. Certain layers of these soils were found to be cemented. Field Investigation The four borings were drilled with buckets ranging in size from 24 inches to 36 inches in diameter by a truck-mounted rotary bucket-type drill rig at the approximate locations shown on the attached Drawing No. 1, entitled "Location of Test Borings." The borings were drilled to depths of 5.0 to 48.0 feet below the existing ground surface. A continuous log of the soils encountered in the borings was recorded at the time of drilling and is shown in derail on Drawing Nos. 2 to 9, inclusive, each entitled "Summary Sheet." • The soils were visually classified by field identification procedures in accordance with the Unified Soil Classification Chart. A simplified description of this classification system is pre- sented in the attached Appendix A at the end of this report. Undisturbed samples were obtained at frequent intervals ahead of the drilling. The drop weight used for driving the sampling tube into the soils was the "Kelly" bar of the drill rig \vliich weighs 1623 pounds, and the average drop was 12 inches. The general procedures used in field sampling are described undsr "Sampling" in Appendix 8 . Loose bag samples were also obtained of the representative soils which may be used in compacted filled ground areas. Laboratory Teste Laboratory tests v*?re performed on all undishjrbed samples of rhe soils in order to determine fhe -:ry density Jnd rnohrure confent. The resuifs of these ?ssrs are presented on Drawing Nos. 2 to ?, incksi-e. ConsolidaHon tests -Aere performed or reoresen^ti /e samples In order to determine the load-settlement characteristics of ?he soils and ffie rssulh of these tests are presented graph- ically on Drawing No. 10, entiHed "Consolidation Curves." EJENTON ENGINEERING. INC. Project No. 69-1'1-UBC La Costa Valley Unit No.< -4-January 16, 1970 In addition to the above laboratory tests, expansion tests were performed on some of the clayey soils encountered to determine their volumetric change characteristics with change in moisture content. The recorded expansions of the samples are presented as follows: Boring No. 1 1 1 2 4 4 Sample No. 4 5 B-3* B-l* 2 B-l* Depth of Sample, in Feet 20.0 25.0 7.0-8.0 6.0-7.0 8.0 6.0-7.0 Soil Description Light olive silty clay Light olive silty clay Light dive silty clay Light olive silry clay Light olive- gray very fine candy ctay Light olfve- gray very fine sandy clay Percent Expansion Under Unit Load of 150 Pounds per Square Foot from Field Moisture to Saturation 3.94 Percent Expansion Under Unit Load of 500 Pounds per Square Foot from Air Dry to Saturation 5.63 7.80 10.87 3.57 6.02 * Indicates sample was remolded to 90 percent of maximum dry density. The general procedures used for the laboratory tests are described briefly in Appendix B. Compaction tests were performed on representative samples of the soils to be excavated to establish compaction criteria. The soils were tested according to the A.S.T.M. D 1557-66T method of compaction which uses 25 blows of a 10 pound hammer dropping 18 inches on each of 5 layers in a 4 inch diameter 1/30 cubic foot mold. The results of the tests are presented as follows: Boring No. 1 1 1 2 2 4 Bog Sample 1 2 3 I 2 1 Depth in Feet .0- 1.0 2.0- 3.0 7.0- 8.0 6.0- 7.0 18.0-19.0 6.0-7.0 Soil Description . Dark gray clay (topsoi!) Light olive, silty very fine sand Light olive, sifty clay Light olive, silty clay with siltstone Light olive-gray stlty fine to medium sand Light olive -gray, vary fine sandy clay Maximum Dry Density Ib/cu ft 114.0 " 118.3 122 . 1 117.0 121.8 122.3 Optii hire ' % dr 16.1 12.2 11.2 13.7 11.6 10.2 BENTON ENGINEERING. INC. Project No. 69-11-14BC -5- _ January 16, 1970 La Costa Valley Unit No.f ( Attsrberg limit tests were performed on selected samples of the soil and the results are presented below: Liquid Plastic Plasticity Group Limit Limit Index Symbol Boring 1, Sample 1 47.6 14.6 33.0 CL Depth 5.0 feet Borirg 1,Sample 4 37.5 15.8 21.7 CL Depth 20.0 feet Borina 1,Sample 5 40.0 14.9 25.5 CL Depth 25.0 feet Borirg 2,Sample 1 54.8 14.5 40.3 CH Depth 5.0 feet Direct shear tests were performed on saturated and drained samples in order to determine the minimum angle of internal friction and apparent cohesion of the various soils. The results of the tests were as follows: Normal Load tn kips/sq ft 0.5 1.0 2.0 0.5 1.0 2.0 0.5 1.0 2.0 0.5 1.0 2.0 0.5 1.0 2.0 Shearing Resistance kips/sq ft 1.66 5.13 4.23 2.35 5.74 6.74 1.10 1.49 1.72 1.73 1.95 2.25 0.76 1.15 1.95 Angle of Internal Friction Degrees 45** i 45** 14 17 38.5 Apparent Cohesiovi Ib/sq ft 800 800 975 1550 375 Boring 1, Sample 3 Depth: 15.0 feet Boring 1, Sample 5 Depth: 25.0 feet Boring 2, Sample 1 Depth: 5.0 feet Borirg 2, Bag 1* Depth: 6.0-7.0 feet Boring 2, Bog 2* Depth: 11 .0 feet * Indicates tests v/ere performed on samples molded to 90 percent of maximum dry density. ** Arbitrarily reduced toaliow for local cementation. BENTON ENGINEERING. INC. ' Project No. 69-11-14BC La Costa Valley Unit Noi -6-January 16 f 1970 Normal Load In kips/sq ft 0.5 1.0 2.0 1.0 2.0 0.5 2.0 Shearing Resistance kips/sq ft 1.05 1.22 1.84 3.34 5.51 1.10 3.64 Angle of Internal Friction Degrees 28 45** 45** Apparent Cohesion Ib/sq ft 725 1000 275 Boring 4, Bag 1* Depth: 6.0-7.0 feet Borirg 4, Sample 3 Depth: 13.0 feet Boring 4, Sample 5 Depth: 23.0 feet * Indicates tests were performed on samples molded to 90 percent of maximum dry density ** Arbitrarily reduced to allow for local cementation Using the lower values of fhe angle of internal friction and apparent cohesion, and the Terzaghi Formula for local shear failure, fhe safe allowable bearing pressures for the soils are determined as follows: , • Local Shear Formula: Q'd = 2B (2/3 c N'c + X Df N' + y BN'y) Assumptions: Undisturbed natural soils (1) Continuous footing 1 foot wide = 2B G2) Depth of footirg = 0.83 = Df Firm soils as Boring 2, Sample 1 <J> = 14° c = 975 Ib/sq ft y = 120 Ib/cu ft N'c = 10.0 N' =4.0 NV = 2.0w ^I I • Q'd = (2/3x975x 10+ 120x .83x4.0+ 120 x 0.5 x 2.0) = 7020 Ib/sq ft Q'd -r- Factor of Safety^ 3 Use maximum of 2300 Ib/sq ft Fill soils compacted to 90 percent of maximum dry density O = 28° c = 725 Ib/sq ft y = 120 Ib/cu ft N'c=17.0 N' =8.0 NV=4.8 Q'd = (2/3x725 x 17.0+ 120 x .83 x 8'.0+120 x 0.5 x 4.$= 9310 Ib/sq ft Q 'd - Factor of Safety r» 3 .0 Use maximum of 2500 Ib/sq ft BENTON ENGINEERING, INC. , 2 " j— UJa. u.UJa 1-1 2- 3- ±- 6- 8- 9- 10- Ir- 12- 10 . ^ 15- 16-SAMPLENUMBtk-fO- $s&/ // / ^wx X ^ X X ~' / / XX > / / yjz7" ' //i ^ X x XX> ^ '/ / / X Xx XX, 'S /v/'XX Y / J ' / / 7^/ / r^~X XX/ L /" ^ f JUMMARY SHEET ( SOWING NO. 1 1 Off A 1 *P(,?VAriON lOO.U * Dark Gray, Slightly Moist, Soft, Highly Cracked, Topsoil Light Olive, Slightly Moist, Very Firm Light Olive, Slightly Moist, Very Firm, Cracked, Occasionally Merging With Lenses of Clay Continued on Dra< CLAY StLTYVERY FINE SAND SILTYCLAY *ing No. 3 DUlVfc ErtEaGVFT. KIPS/FT.14.6 40.6 31.2 V 5a ti_i — >. **• o ^ 5- 18.2 12.8 15.5 >-V- )— d( 33a -1 106.6 122.9 118.7 iH£A8RESISTANCEKIPS/SQ. FT.GROUPSYMBOLCL j - Indicates Undisturbed Drive Sample Q - Indicates Loose Bag Sample The elevations shown on these Summary Sheets were obtained by interpolation of the contours on a Tentative Map of La Costa Valley Unit No. 5 prepared by Rick Engineering Company 69-1I-I48C flENTON £/-iGJNt???iNG, Ox.A '/ViNO NO. 2 1 «o • £ *c 13 X» £ o 3 5 1 28u 3 q 1 *i 1 5>- HI•X u.Ula t-rIf 19- 20- • 21- 22- 24- 25- 26- 27- 28- 29-SAW.PLENUMBER/ / / /7 / A / / ; 7@y / / / V / / / / / / / s/ / // / * *&7/ / / *a ^m fp&&X6/ii SUMMARY SHEET ( BORING NO. 1 (Cpnt.) Light Olive, Slightly Moist, Very Rrm, Cracked, Occasionally Mergirg With L«rses of Clay Light Olive, Slightly Moist, Very Firm . ' SILTY CLAY • VERYRNE SANDY SJLTSTONE 1 DRIVE ENERGYFT. KIPS/FT.19.5 13.3 60.0 Q 3-1 S- >. £ 2 *£ o a 11.2 13.7 13.2 >- »-^ij% It i 2 128.7 122.2 117.3 SHEAR 1RESISTANCEKIPS/SO. FT. |GROUPSYMBOLCL —1 69-1I-14BC 8ENTOM ENGiN€ES!NG, INC. z z£££ui£J — o o 4- 5- 6- 7- 8- 9- 10- 11- 12-^ 13- * 14- 15~ 16-J SAMPLENUM&ESd r ' i*i» j »T •4%^ / / r / / / / / / r / / ¥?'*y / / ./ / Y^</ /. / / ' / / ^ / S/ /: / /' / / W.: / /y/>' / /' / /i / /y / * c / / J S \Y / ' // - ^7/ / /\S / ' SUMMARY SHEET fVQSJNG NO 2 ELEVATION 132. Q'u Dark Gray, Slightly Moist, Soft, 30 Percent Gravel to llnch Dark Gray, Slightly Moist, Soft Light Olive, Moist, Firm Very Rrm ; Continued on Dr< GRAVELLY CLAY CLAY SILTYCLAY awing No. 5 DkMVE ENE8GYFT. KIPS/FT.8.1 21.1 50.3 FIELD jMOUTUKE*/» DRY WT. |21.4 18.3 12. 4 >-. i-i 5 "• s4>- v» * 3Q -1 100.7 111.4 125.8 SHEARRESISTANCEKIPS/SQ. FT.GROUPSYMBOLCH z o 1 M/~ DSAWiNO N Y SHEET __l.{C<?nt.) Light Olive, Moist, Very 4 Firm SILTYCLAY Light Olive-gray, Moist, Very Firm, Lightly Cemented Fine Cemented Sandstone i ^ ~ ir! £» - * i~ r, Cs, ui. I 39.0 SILTYFINE TO MEDIUM SAND 50.8 < o 10.2 J117.1 10.3 109.1 fi PROJECT NO. 69-U-14BC BENTON ENGfNEERfNG, INC. DRAWING NO 5 SUMMARY SHEET SORING NO. 3 ELEVATION 45. Q'DRIVE ENEMGYFT. KIPS/FT.at 03 i SHEARRESISTANCEKIPS/SQ. FT.Medium Brown, SHghriy Moist, 4 Medium Firm, Scattered Gravel to 2 ! riches > Brown, Moht, Firm Gray, Moist, Very Firm, 20 Percent Gravel to 2 Inches Brown, MoJst, Very Firm Brown, Moist, Very Firm, 50 to 60 Percent Gravel to 3 Inches, Cobbles to 8 Inches CLAYEY FINE TO MEDIUM SAND -I6.2rl3.5+l CLAYEY FINE SAND GRAVELLY FINE TO MEDIUM SANDY CLAY -16.2-15.5-114 CLAYEY FINE TO MEDIUM SAND CLAYEY FINE TO MEDIUM SANDY GRAVEL 69-11-14BC 8ENTON cNGiNc£-i!f-iG, INC. DSAWING NO. 6 ^""" >— 1Ua. u.UJa J 2-1 3-j 4- — - 6- *• 7- - • 9- 10- 13- ' 14- 15- 17- 18- 19-SAMPLENUMfcEft.-/'. V'-" ^ — r . . . T* 1@ S5"S i-fWp-i O •*— sis ;••; .'..;:;.ii SUMMARY SH€ET SORING NO,-_jl__ fLEViTIQN 91.Q1 Brown, Slightly Moist, Soft Cracked Firm Light Gray-browh, Moist, Very Firm . Light Olive-gray, Moist, Very Firm, With Some Alternating Layers of Silty Clay to 10 Feet rV>ntinn*»el nn Dr ' FINE SANDY CtAY CLAYEY FINE TO MEDIUM ;.'-• SAND VERY FINE SANDY CLAY (Merges) VERY FINE SANDY SILT nw!w Klo . S DKIVE ENERGTFT. KIPS/FT.•14.6- 35.7 39.0 29.2 ujt-;°* 503*—">->- UJ V> ^ iZ o Q ** 8.8 12.1 12.1 11.6 il §3 -J08 3 120.4 119.8 119.3 SHEARESISTANCEPS/SO. FT.** X. • -$. Jilo PRO.jFCf .MO. 69-U-J4BC 1ENTON INC. DRAWING NO. • 7 a O . J ?• •_ >~3. tu»— tilc. u.LU 0 — 1A -/U 21- 22- 23- 94^*» 25- 26- • 27- zo 29- 30— 31- 32- 33~ qA_ 35- o i«^3o~ 37- 38- o! lc ^ |S f*J^Z 7*Y A / /( / A / . \ / / f I ./ Jf ,^ASi7 ' I/ A 77V I/I /Tl/<K-*VVA} A /\/V/ /y/¥,/(/A/< T/T ^ ij/ j/ \/ A X /\ /A / y^ j A\A> . -\ Q j.-...— (".UMMARY SKi BORING NO. ^ r* <* •.* f*. i ..(Cent.) Light Olive-gray, Moist, j VERY FINE Very Firm, Lens of Clay SANDY SILT Light Olive -gray, Moist, Very Firm Red -brown, Brown and Gray, Moist, Very Firm Thin Soft Plastic Clay Seam, Dips Down 28° at Bearing N 15° E Red-brown, Brown and Gray Moist, Very Firm Continued on Drc (Merges) SLIGHTLY CLAYEY FINE TO MEDIUM SAND SILTY CLAYSTONE CLAYEY FINE SAND iwing No. 9 > ! % £ '' -Jtil s, cr: 2 v* |C !3^' ^ i[r! 7 t-j ^ ~ •- c 19 5T 7 . J ^ 45.0 50.0 55.0 U, Q -10. 19. 18. 17. PROJECT NO. 69-11-14BC BENTON ENGINEERING, !NC. i t .— -i — . 4 5 1 >- i 1r • - 'f i, i 'r. v~ •-• !l~: ~, <« z •s 3 \< <c **7- ' ^; v--i ---• :";; "" ! a: iT t 107.2 110.6 117.8 1 ; j j ii DRAWING NO. 8 SS V- -OJ .X U. 1Ua —38- O. A **«< 3«"Z SUMMARY SHEET BORING 2 tuj -^I £ UjV- o3J _•>—>- ^^ at "- O ° ** >- t^ >s> **• 13 13 Bt' 3dt- 1^1 39- 40- 41-- 42- 43- Red-brown, Brown and Gray, Moist, Very Firm Dark Gray 44-E 45 Lime-cemented Sandstone Lenses to 48 Feet 46 47-t 43 Aioa CLAYEY FINE SAND 50.0 16.0 117.7 66.6 16.2 117.7 jaoj;cr NO 69-11-14BC BEN7ON ENGINEERING, INC. DSAWtNG NO «CONSOLIDATION - PERCENT OF SAMPLE THICKNESS~j O — • N3 -" *•?>3 0 )>- . 4 ~ CONSOLIDATION CURVES LOAD IN X!PS PER SQUARE FOOT 06 0.8 1.0 2 4 — —— L.C^""4' ^^^-^ 6 8 10 16 Boring 3 Sample ] Depth 1.5' | t t I i i . i 1 1 i j ; ! < i_ .3 U • - ' -af" 5 I ' ! ~r^^ii "^^~^i — \1 \ ! , I ' i \ l •r r" ".-'-»*" ii i '. ;-? | ( ii ' j ! '""• ^ c or so i : u v- "" i or c r r i c d rroi > . • *• • - p Son Boring 4 Sample 1 Deofh 3' i 1 I 1 t f — . -— i ^.~, .er-r »,„ i ' k N; N • A•-'•** - r\.p -. 0 j 0 /7' Xi >IN: & r\ ,,X -v. CUT AKD FILL StOfi StABlUTY ANiAlYSlS LA CC5TA VALLEY UNIT NO, 5 NORTHEAST OF ALICANTE ROAD SOUTH OF ALGA ROAD SAN DIEGO COUNTY, CALIFORNIA rtOJECT NO. 69-11-I4BC BENTON ENGINEERING, INC. DRAWING NO. II BENTON ENGINEERING, ING. APPLIED SOIL MECHANICS FOUNDATIONS 6741 EL CAJON BOULEVARO SAN DIEGO. CALIFORNIA 92115 PHILIP HENKINS BENTON . S»N DIEGO-. 583-S634 PRESIDENT . CIVIL ENGINEER U* MCSAt 469-8654 APPENDIX AA STANDARD SPECIFICATIONS FOR PLACEMENT Of COMPACTED FILLED GROUND 1. General Description. The objective is to obtain uniformity and adequate internal strength in filled ground by proven engineering procedures and tests so that the proposed structures may be safely supported. The procedures include the clearing and grubbing, removal of existing structures, preparation of land to be filled, filling of the land, the spreading, and compaction of the filled areas to conform with the lines, grades and slopes as shown on the accepted plans. ' The owner shall employ a qualified soils engineer to inspect and test the filled ground as placed to verify the uniformity of compaction of filled ground to the specified 90 percent of maximum dry density. The soils engineer shall advise the owner and grading contractor immediately if any unsatisfactory conditions are observed to exist and shall have the authority to reject the compacted filled ground until such time that corrective measures are taken necessary to comply with the specifications. It shall be the sole responsibility of the grading contractor to achieve the specified degree of compaction. 2. Clearing, Grubbing, and Preparing Areas to be Filled. (a) AH brush, vegetation and any rubbish shall be removed, piled and burned or otherwise disposed of so as to leave the areas to be filled free of vegetation and debris. Any soft, swampy or otherwise unsuitable areas shall be corrected by draining or removal, or both. (b) The natural ground which is determined to be satisfactory for the support of the filled ground shall then be plowed or scarified to a depth of at least six inches (6"), and until the surface is free from ruts, hummocks, or other uneven features which would tend to prevent uniform compaction by the equipment to be used. (c) Where fills are made on hilfsides or exposed slope areas, greater than 10 percent, horizontal benches shall be cut into firm undisturbed natural ground in order to pro- vide both lateral and vertical stability. This is to provide a horizontal base so that each layer is placed and compacted on a horizontal plane. The initial bench at the toe of the fill shall be at least 10 feet in width on firm undisturbed nature! ground at the elevation of the toe stake placed at the natural angle of repose or design slope. The soils engineer shall determine the width and frequency of all succeeding benches which will vary with fhe soil conditions and the steepness of slope. APPENDIX AA -2 - (d) After the natural ground has been prepared, it shall then be brought to the proper mois- ture content and compacted to not less than ninety percent of maximum density in accordance with A.S.T.M. D-1557-66T method that uses 25 blows of a 10 pound hammer falling from 18 inches on each of 5 layers in a 4" diameter cylindrical mold of a l/30th cubic foot volume. 3. Materials and Special Requirements. The fill soils shall consist of select materials so graded that at lease 40 percent of the material passes a No. 4 sieve . This may be obtained from the excavation of banks, borrow pits of any other approved sources and by mixing soils from one or more sources. The material uses shall be free from vegetable matter, and other de- leterious substances, and shall not contain rocks or lumps of greater than 6 inches in diameter. If excessive vegetation, rocks, or soils with inadequate strength or other unacceptable physical characteristics are encountered, these shall be disposed of in waste areas as shown on the plans or as directed by the soils engineer. If during grading operations, soils not encountered and tested in the preliminary investigation are found, tests on these soils shall be performed to determine their physical characteristics. Any special treatment recommended in the preliminary or subsequent soil reports not covered herein shall become an addendum to these specifications. The testing and specifications for the compaction of subgrade,subbase, and base materials for roads, streets, highways, or other public property or righfs-of-way shall be in accordance with those of the governmental agency having jurisdiction. 4. Placing, Spreading, and Compacting Fill Materials. (a) The suitable fill material shall be placed in layers which, when compacted shall not exceed six inches (6"). Each layer shall be spread evenly and shall be throughly mixed during the spreading to insure uniformity of material and moisture in each layer. (b) When the moisture content of the fill material is below that specified by the soils ergineer, water shall be added until the moisture content is near optimum as specified by the soils engineer to assure thorough bonding during the compacting process. (c) When the moisture content of the fill material is above that specified by the soils engineer, the fill material shall be aerated by bladlng and scarifying or other satis~ factory methods until the moisture content Is near optimum as specified by the soils engineer. (d) After each layer has been placed, mixed and spread evenly, it shall be thoroughly compacted to not less than ninety percent of maximum density in accordance with A.S.T.M. D-1557-66T modified as described in 2 (d) above. Compaction shall be accomplished with sheepsfooi- rollers, multiple-wheel pneumatic-tired rollers, or other approved types of compaction equipment, such as vibratory equipment that is specially designed for certain soil types. Rollers shall be of such design {hat they will be able r . r APPENDIX AA - 3 - to compact the fill material to the specified density. Rolling shall be accomplished while the fill material is at the specified moisture content. Rolling of each fayer shall be continuous over Its entire area and the roller shgll make sufficient trips to insure that the desired density has been obtained. The entire areas to be filled shall be compacted. (e) Fill slopes shall be compacted by means of sheepsfoot rollers or other suitable equipment. Compacting operations shall be continued until the slopes are stable but not too dense for planting and until there is no appreciable amount of loose soil on the slopes. Compacting of me slopes shall'be accomplished by backroiling the slopes in increments of 3 to 5 feet in elevation gain or by other methods producing satisfactory results. (f) Field density tests shall betaken by the soils engineer for approximately each foot in elevation gain after compaction, but not to exceed two feet in vertical height between tests. Field density tests may be taken at intervals of 6 inches in elevation gain if required by the soils engineer. The location of the tests in plan shall be so spaced to give me best possible coverage and shall be taken no farther apart than 100 feet. Tests shall be taken on corner and terrace lots for each two feet in elevation gain. The soils engineer may take additional tests as considered necessary to check on the uniformity of compaction. Where sheepsfoot rollers are used, the tests shall be taken in the com- pacted material below the disturbed surface. No additional layers of fill shall be spread until the field density tests indicate mat the specified density has been obtained. (g) The fill operation shall be continued in six inch (6") compacted layers, as specified above, until the fill has been brought to the finished slopes and grades as shown on the accepted plans. 5. Inspection. Sufficient inspection by the soils engineer shall be maintained during the filling and compacting operations so that he can certify that the fill was constructed in accordance with the accepted specifications. \6. Seasonal Limits. No fill material shall be placed, spread, or rolled if weather conditions increase the moisture content above permissible limits. When the work is interrupted by rain, fill operations shall not be resumed until field tests by the soils engineer indicate that the moisture content and density of the fill are as previously specified. 7. Limiting Values of Nonexpansive Soils. Those soils mat expand 2.5 percent or less from air dry to saturation under a unit load of 500 pounds per square foot are considered to be nonexpansive. 8. All recommendations presented In the "Conclusions" section of the attached report are a part of these specifications. r BENTON ENGINEERING, INC. APPLIED SOIL MECHANICS FOUNDATIONS 6741 EL CAJON BOULEVARD SAN DIEGO. CALIFORNIA 92115 PHILIP HENKING BENTON PRESIDENT - CIVIL ENGINEER SOIL DESCRIPTION APPENDIX A Unified Soil Classification Chart* SAN DlEGO: 583-5634 LA MESA: 469-SSS4 GROUP TYPICAL SYMBOL NAMES COARSE GRAINED, More than half of material is larger than No. 200 sieve **size. GRAVELS CLEAN GRAVELS More than half of coarse fraction is larger than No. 4 sieve size but smaller GRAVELS WITH FINES than 3 inches SANDS M re than half of coarse fraction is smaller than No. 4 sieve size (Appreciable amount of fines) CLEAN SANDS SANDS WITH FINES (Appreciable amount of fines) FINE GRAINED, More than half of material is smaller than No. 200 sieve size.SILTS AND CLAYS Liquid Limit Less than 50 SILTS AND CLAYS Liquid Limit Greater than 50 III. HIGHLY ORGANIC SOILS GW Well graded gravels, gravel-sand mixtures, little or no fines. GP Poorly graded gravels, gravel-sand mixtures, little or no fines. GM Silty gravels, poorly graded gravel - sand-si It mixtures. GC Clayey gravels, poorly graded gravel- sand-clay mixtures. SW Well graded sand, gravelly sands, little or no fines. SP Poorly graded sands, gravelly sands, little or no fines. SM Silty sands, poorly graded sand-silt mixtures. SC Clayey sands, poorly graded sand-clay mixtures. ML Inorganic silts and very fine sands, rock flour, sandy silt or clayey-silt-sand mixtures with slight plasticity. CL .Inorganic clays of low to medium plas- ticity, gravelly clays, sandy clays, silty clays, lean clays. OL Organic silts and organic silty-clays of low plasticity. MH Inorganic silts, micaceous or diatoma- ceous fine sandy or silty soils, elastic silts. CH Inorganic clays of high plasticity, fat clays. OH Organic ciays of medium to high plasticity. PT Peat and other highly organic soils. Adopted by the Corps of Engineers and Bureau of Reclamation in January, 1952. All ,:„,.., ,:-.„_ — O.L:- _i—•. —.11 rn.ii r C BENTON ENGINEERING. INC. APPLIED SOIL MECHANICS FOUNDATIONS 674t EL CAJON BOULEVARD SAN DIEGO. CALIFORNIA 921 IS PHILIP HENKING BENTON AODCMPllV D SAN DlECO: SS3-5SS4 PRESIDENT . CIVIL ENGINEER ArrtlNUIA IS LA MESA: 469-5634 Sampling The undisturbed soil samples are obtained by forcing a special sampling tube into the undisturbed soils at the bottom of the boring, at frequent intervals below the ground surface. The sampling tube consists of a steel barrel 3.0 inches outside diameter, with a special cut- ting tip on one end and a double ball valve on the other, and with a lining of twelve thin brass rings, each one inch long by 2.42 inches inside diameter. The sampler, connected to a twelve inch long waste barrel, is either pushed or driven approximately 18 inches into the soil and a six inch section of the center portion of the sample is taken for laboratory tests, the soil being still confined in the brass rings, after extraction from the sampler tube. The samples are taken to the laboratory in close fitting waterproof containers in order to retain the field mois- ture until completion of the tests. The driving energy is calculated as the average energy in foot-kips required to force the sampling tube through one foot of soil at the depth at which the sample is obtained . Shear Tests The shear tests are run using a direct shear machine of the strain control type in which the rate of deformation is approximately 0.05 inch per minute. The machine is so designed that the tests are made without removing the samples from the brass liner rings in which they are se- cured. Each sample is sheared under a normal load equivalent to the weight of the soil above the point of sampling . In some instances, samples are sheared under various normal loads in order to obtain the internal angle of friction and cohesion . Where considered necessary, samples are saturated and drained before shearing in order to simulate extreme field moisture conditions. Consolidation Tests The apparatus used for the consolidation tests is designed to receive one of the one inch high rings of soil as it comes from the field. Loads are applied in several increments to the upper surface of the test specimen and the resulting deformations are recorded at selected time intervals for each increment. Generally, each increment of load is maintained on the sample until the rate of deformation is equal to or less than 1/10000 inch per hour. Porous stones are placed in contact with the top and bottom of each specimen to permit the ready addition or release of water. Expansion Tests One inch high samples confined in rhe brass rings are permitted to air dry at 105°F for at least 48 hours prior to placing into the expansion apparatus. A unit load of 500 pounds per square foot is then applied to the upper porous stone in contact with the top of each sample. Water is permitted to contact both the rop and bottom of each sample through porous stones. Continuous observations are made until downward movement stops, The dial reading is recorded and expansion is recorded until the rate of upward movement is fess than 1/10000 inch per hour. I wj * »' f I