HomeMy WebLinkAbout2328 CAMINO ROBLEDO; ; CB000569; PermitCity of Carlsbad
Retaining Wall Permit Permit No:CB000569
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
2328 CAM1NO ROBLEDO CBAD
RETAIN
2552721300 Lot#:
$295.00 Construction Type:
RETAINING WALL 20SF
0
NEW
Status: ISSUED
Applied: 02/17/2000
Entered By: GMF
Plan Approved: 03/08/2000
Issued: 03/08/2000
Inspect Area:
Applicant:
LORCO
4488 SALISBURY DR
CARLSBAD CA 92008
619-434-8945
Total Fees: $25.26
M&BROWN-BARRY MARY JOE
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Strong Motion Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
TOTAL PERMIT FEES
ami m n?
C-JPRHS7 15-67
4.70
0.00
9.56
0.00
$1.00
$0.00
$0.00
$0.00
$25.26
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the Imposition* of fees, dedications, reservations, or other exactions hereafter collectively
referred to as fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(3), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactjy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired,
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161
PPLICATIOte
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO.
EST. VAL.
Plan Ck. Deposit
Validated By,
Date
Address (include Bldg/Suite #)Business Name (at this address)
State/Zip Telephone # Fax #
Name Address City State/Zip Telephone #
Name Address City State/Zip Telephone #
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he Is exempt therefrom, and the basis for the alleged
exemption. f\ny violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1*500]).
Name a -xc -7 -7 A Address T2>State License # *7 *JJ L-L£j License Class ^
City State/Zip Telephone #
Citv Business License # / 3Oft <* <i ^
Designer Name Address
State License #
City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
O I have anpVwill maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. MvXorker's compensation insurance carrier and policy number are:
InsursjXi Company _ Policy No. _ Expiration Date _
(TfcflS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to MCU/B workers' compensation coverage is unlawful, and shall subject an employer to crimtaaf penahfcs and ddl fines up to one hundred
thousand dollars ($100.00(1, In addfchffTto the cost of compensation, damages as provided for In Section 3706 of the Labordbda. MerjfttanUattomey'B fees.Jl _^^ '•M^ I / n / '/ *r^
SIGNATURE V^ DATE
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Lew does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
Q I am exempt under Section _ Business and Professions Code for this reason:
1 . I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with, the following person (firm) to provide the proposed construction {include name I address / phone number / contractors license number}:
4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25S05, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES O NO
IF ANY OF THE ANSWERS ARE YES, A RNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above Information is correct and that the information on the plans Is accurate. I agree to comply with all
City ordinances and State laws relating to btllding construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO/AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHIOH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for ex
EXPIRATION: Every permit issued by the
authorized by such permit is not commencdEl within
at any time after the work is commenced ft
APPLICANT'S SIGNATURE
Ivations over 5'0" deep and demolition or construction of structures over 3 stories in height.
uilding Official under the provisions of this Code shall expire by limitation and become nujf and void if
180 days from the date of such permit or if the building or work authorized by such gfermit is susp;
OfKnl u( f 00 days (Section 106.4.4 Uniform Building Code). —"7
DATE ^"
&,
WHITE: File YELLOW: Applicant PINK: Finance
ie building or work
ided or abandoned
City of Carlsbad Bldg Inspection Request
For: 4/26/2000
Permit^ CB000569 Inspector Assignment: TL
Title: RETAINING WALL 20SF
Description:
Type: RETAIN Sub Type:
Phone: 7604348945
Job Address: 2328 CAMINO ROBLEDO
Suite: Lot 0
Location: Inspector: __^
APPLICANT LORCO
Owner: BARRY WILLIAM M&BROWN-BARRY MARY JOE
Remarks:
Total Time: Requested By: LORCO
Entered By: CHRISTINE
CD Description A n Act_ Comments
69 Final Masonry
Associated PCRs
Inspection History
Date Description Act Insp Comments
3/21/2000 23 Gas/Test/Repairs AP TL
3/21/2000 39 Final Electrical WC TL
3/21/2000 66 Grout AP TL DRAIN & GRAVEL
3/13/2000 11 Ftg/Foundation/Piers AP TL
City of Carlsbad
Public Works Engineering
BUILDING PLANCHECK CHECKLIST
RETAINING WALL
BUILDING PLANCHECK NUMBER: CB
BUILDING ADDRESS:
PROJECT DESCRIPTION: Retaining Wall
ASSESSOR'S PARCEL NUMBER:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, Information
and/or specifications provided in your submittal;
therefore, any changes to these items after this date,
including field modifications, must be reviewed by this
office to insure continued conformance with applicable
codes. Please review carefully all comments attached,
as failure to comply with instructions in this report can
result in guspei/sijn of permit to build.
By:
Please see
marked wi
or specifi
DENIAL
iched report of deficiencies
:e necessary corrections to plans
is for compliance with applicable
codes and standards. Submit corrected plans
and/or specifications to this office for review.
ATTACHMENTS
RIght-of-Way Permit Application
ENGINEERING DEPT. CONTACT PERSON
NAME: KATHLEEN M. FARMER
City of Carlsbad
ADDRESS: 1635 Faraday Av«
Carlsbad, CA 92008
PHONE: (76O) 602-2741
mWORD»OOCfflCHKLSTVW*lno Wtf BuUng Pttnctet* CUM Form KF-doe
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (76O) 6O2-2720 • FAX (76O) 602-8562
2ND/
o a
BUILDING PLANCHECK CHECKLIST
RETAINING WALLS
1. Provide a fully dimensioned site plan drawn to scale. Show:
North Arrow
B. Existing & Proposed Structures
(dimensioned from street)
'C'
2. Show on site plan:
A. Drainage Patterns -
B. Existing & Proposed Slopes —
C. Existing Topography -
3. Include on title sheet:
tAr*!§ite Address
(location and height)
^
Import/Export
(Grading Permit and Haul Route Permit may be required)
Q Q 4. Project does not comply with the following Engineering Conditions of approval
for Project No.
Conditions were complied with by:Date:
MISCELLANEOUS PERMITS
5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way.
A separate Right-of-Way issued by the Engineering Department is required
for th« following:
Please obtain an application for Right-of-Way permit from the Engineering
Department.
Pagel
Kw.MOM
3"octi
o
o o
I i
n
Plan Check No. CBOoO Address
Planner Paul Godwin Phone (760) 602-4625
Type of Project & Use: Sfft-fld. uJall
Zoning: P"£ General Plan:
Net Project Density:
Facilities Management Zone:
DU/AC
CFD 'in/nut) #_
Circle One
Date of participation:Remaining net dev acres:
(For non-residential development: Type of land used created by
this permit: )
Legend:X Item Complete
Environmental Review Required:
DATE OF COMPLETION:
YES
Item Incomplete - Needs your action
NO TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
YES NO TYPE
DATE
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
NO
NO
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES
CA Coastal Commission Authority? YES
If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite
200, San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES NO
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
I I I I Inclusionary Housing Fee required: YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!)
Site Plan:
J 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
I 2. Provide legal description of property and assessor's parcel number.
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
I I | | 2. Accessory structure
Front:
Interior Side:
Street Side:
Rear:
Structure separation
I M I 3. Lot Coverage:
Required
Required
Required
Required
setbacks:
Required
Required
Required
Required
: Required
Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
4. Height:Required Shown
I I 5. Parking: Spaces Required
Guest Spaces Required
Additional Comments
Shown
Shown
>A& Elan IS \t\ aa £ &LJ a T"£ . Labg• i I,.TJ i ' . v)CiflftTS . JQ-y ci\mcniiQn5. _^^___
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
MINIMUM REQUIREMENTS FOR
Retaining Wall/Sloping Backfill
San Diego Area Chapter
International Conference of Building Officials
CvltiMd Chuta Vtea. Conwdo M Uw. El C^en. B C«n«e, EneMUk EMondUo, IrnpwW BMOL U M«H. Lvrnn Qnm.
NX** C*. OnmU* KM*. S*t Otop C*y. Swi D»go County. Sm UVOM. SMN. HIMBMtfLTmajM. Vbu
CHAPTER
POLICY
222
Novtmbtr
1992
Construction of retaining walls, except those less
than three feet high and not supporting surcharge,
requires a permit and is regulated by local building
codes.
This chapter policy outlines requirements for re-
taining walls with sloping backfill. Chapter Policy
221 covers retaining walls with level backfill.
Contact your local building department for infor-
mation on how to obtain a permit for a retaining wall.
I. INSPECTIONS
Inspections must be performed during several
phases of construction. Please call for inspections at
the following times:
A. When the footing has been dug with the steel
tied securely in its final position, and the si te is ready
for the concrete to be placed, a footing inspection is
needed.
B. Amasonrypregroutinspectionisrequiredwhen
the block has been laid and the steel is in place, but
before the grout has been placed.
1. If cleanout holes are used, block may be laid to
the full height at the grout pour before calling
for the pregrout i nspcction. Grout shall be placed
in a continuous pour in grout lifts not exceeding
6 feet.
2. If cleanout holes are not used, a masonry
pregrout inspection is required prior to each
grout pour. Block cannot be laid higher than the
grout pour. Note thatcleanoutsare required for
all grout pours over 5 feet in height.
C. After grouting is completed and rock or rubble
wall drains are in place, but before earth backfill is
placed, call for a backfill/drainage inspection.
D. When all work has been completed call for a
final inspection.
tt WALL HEIGHT
Wall height is measured from the top of the footing
to the top of the wall. Wallsnot shown in Tables Aand
B on page 2 must be designed specifically for the
existing condition. The walls shown here are designed
to retain earth banks from level to a slope of 1
horizontal tol vertical (sloping surcharge). No building
foundation, driveway, or other loading on the upper
level is allowed within a distance equal to the height
of the wall.
m. BLOCK
All block must be type "N" grouted solid with '
f'M« 1,500 pri.
IV. MIX REQUIREMENTS
Note that tat of plastic cement t« not permitted in
retaining walls located in Seismic Zone No. 3 or 4.
A. The concrete mix for footings must meet a
compressive strength of f'c - 2,000 psi minimum, or
the following proportions by volume:
1 part Portland cement
2V, parts sand
3V, parts Y4-inch maximum-size gravel
7 gallons of water maximum per sack of cement
B. The mortar mix must have a compressive
strength equal to 1,800 psi minimum. One possible
mix contains the following proportions by volume:
1 part Portland cement
3V, parts sand
V4 part hydrated lime or lime putty
C. Grout must have a compressive strength equal
to 2,000 psi minimum. One possible mix contains the
following proportions by volume:
1 part Portland cement
3 parts sand
2 parts pea gravel (*/B-inch aggregate)
Add water until pouring consistency is achieved
without segregation of the grout constituents. Rod or
vibrate immediately. Rerod or revibrate grout about
10 minutes after pouring to ensure solid consolida-
tion. Stop grout 2 inches from top of masonry units
when grouting of second lift is to be continued at
another time.
Note: All cells mutt be filled solid with grout.
V. MORTAR KEY
To insure proper bonding between the footing and
the first course of block, a mortar key must be formed
by embedding a flat 2x4 flush with and at the top of
the freshly poured footing. It should be removed after
the concrete has started to harden (about 1 hour). A
mortar key may be omitted if the first course of block
is set into the fresh concrete when the footing is
poured and a good bond is obtained.
VI. WALL DRAINS
Wall drains (four-inch-diameter) must be placed at
6-foot intervals along the length of the wall and
located just above the level of the soil or paving on the
front face of the wall. The drains may be formed by
placing a block on its side at 6-foot intervals, by
leaving out the mortar in the vertical spaces between
all the blocks (head joint) in the first course above the
soil or paving on the front face of the wall or by any
Nov«mbar1»2 San Diego Area Chapter * ICBO • Chaptar Policy 222 Paga 3 of 4
Figure I/Type I retaining wall with sloping backfill
Concrete
block
2" minimum to - >
6" maximum i •
2-#3 bars
typical
3" clear typical
Lap splice
(See Section VIII.)
Slope of retained earth
(given as horizontal run
to vertical rise)
Horizontal steel
(See Section VIII
for applications.)
Wall thickness
6" when T»A
8* when T-B
2" clear
Reinforcing steel/ R
Gravel backfill
12" wide
Mortar key
(see section V.)
12" minimum concrete
depth. 12" minimum into
natural ground or approved
compacted fill
Note: A minimum of 7 feet must be provided horizontally from the toe of the footing
to daylight where the ground slopes away from the base of the wan.
By:.
City of Carlsbad
Engiriooring Department
BUILDING PLANCHECK CHECKLIST
RETAINING WALL
BUILDING PLANCHECK NUMBER: CB
BUILDING ADDRESS:
PROJECT DESCRIPTION: Retaining Wall
ASSESSOR'S PARCEL NUMBER:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items
after this date, including field modifications, must
be reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to
comply with instructions in this report can result
in suspension of permit to build.
Date:
DENIAL
Please see the attached report of deficiencies
marked with LJ. Make necessary corrections to
plans or specifications for compliance with
applicable codes and standards. Submit corrected
plans and/or specifications to this office for
review.
By:.Date:
By:.Date:
By:.Date:
ATTACHMENTS
D Right of Way Permit Application
ENGINEERING DEPT. CONTACT PERSON
NAME: MICHELE MASTERSON
City of Carlsbad
ADDRESS: 2075 Las Paimai Drive
PHONE: 1619V 438-1161. Ext. 4315
P:\POC1\CHKLST\WAU.
2O75 Uas Paimas Dr. - Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894
cirr
PLANNING DKFAKTMENT
J
dc
Y-=r-Jo