Loading...
HomeMy WebLinkAbout2328 CAMINO ROBLEDO; ; CB000569; PermitCity of Carlsbad Retaining Wall Permit Permit No:CB000569 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: 2328 CAM1NO ROBLEDO CBAD RETAIN 2552721300 Lot#: $295.00 Construction Type: RETAINING WALL 20SF 0 NEW Status: ISSUED Applied: 02/17/2000 Entered By: GMF Plan Approved: 03/08/2000 Issued: 03/08/2000 Inspect Area: Applicant: LORCO 4488 SALISBURY DR CARLSBAD CA 92008 619-434-8945 Total Fees: $25.26 M&BROWN-BARRY MARY JOE Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee TOTAL PERMIT FEES ami m n? C-JPRHS7 15-67 4.70 0.00 9.56 0.00 $1.00 $0.00 $0.00 $0.00 $25.26 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition* of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(3), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactjy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired, CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 PPLICATIOte CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated By, Date Address (include Bldg/Suite #)Business Name (at this address) State/Zip Telephone # Fax # Name Address City State/Zip Telephone # Name Address City State/Zip Telephone # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he Is exempt therefrom, and the basis for the alleged exemption. f\ny violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1*500]). Name a -xc -7 -7 A Address T2>State License # *7 *JJ L-L£j License Class ^ City State/Zip Telephone # Citv Business License # / 3Oft <* <i ^ Designer Name Address State License # City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. O I have anpVwill maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. MvXorker's compensation insurance carrier and policy number are: InsursjXi Company _ Policy No. _ Expiration Date _ (TfcflS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to MCU/B workers' compensation coverage is unlawful, and shall subject an employer to crimtaaf penahfcs and ddl fines up to one hundred thousand dollars ($100.00(1, In addfchffTto the cost of compensation, damages as provided for In Section 3706 of the Labordbda. MerjfttanUattomey'B fees.Jl _^^ '•M^ I / n / '/ *r^ SIGNATURE V^ DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Lew does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Q I am exempt under Section _ Business and Professions Code for this reason: 1 . I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with, the following person (firm) to provide the proposed construction {include name I address / phone number / contractors license number}: 4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25S05, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES O NO IF ANY OF THE ANSWERS ARE YES, A RNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above Information is correct and that the information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to btllding construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO/AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHIOH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for ex EXPIRATION: Every permit issued by the authorized by such permit is not commencdEl within at any time after the work is commenced ft APPLICANT'S SIGNATURE Ivations over 5'0" deep and demolition or construction of structures over 3 stories in height. uilding Official under the provisions of this Code shall expire by limitation and become nujf and void if 180 days from the date of such permit or if the building or work authorized by such gfermit is susp; OfKnl u( f 00 days (Section 106.4.4 Uniform Building Code). —"7 DATE ^" &, WHITE: File YELLOW: Applicant PINK: Finance ie building or work ided or abandoned City of Carlsbad Bldg Inspection Request For: 4/26/2000 Permit^ CB000569 Inspector Assignment: TL Title: RETAINING WALL 20SF Description: Type: RETAIN Sub Type: Phone: 7604348945 Job Address: 2328 CAMINO ROBLEDO Suite: Lot 0 Location: Inspector: __^ APPLICANT LORCO Owner: BARRY WILLIAM M&BROWN-BARRY MARY JOE Remarks: Total Time: Requested By: LORCO Entered By: CHRISTINE CD Description A n Act_ Comments 69 Final Masonry Associated PCRs Inspection History Date Description Act Insp Comments 3/21/2000 23 Gas/Test/Repairs AP TL 3/21/2000 39 Final Electrical WC TL 3/21/2000 66 Grout AP TL DRAIN & GRAVEL 3/13/2000 11 Ftg/Foundation/Piers AP TL City of Carlsbad Public Works Engineering BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CB BUILDING ADDRESS: PROJECT DESCRIPTION: Retaining Wall ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, Information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in guspei/sijn of permit to build. By: Please see marked wi or specifi DENIAL iched report of deficiencies :e necessary corrections to plans is for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. ATTACHMENTS RIght-of-Way Permit Application ENGINEERING DEPT. CONTACT PERSON NAME: KATHLEEN M. FARMER City of Carlsbad ADDRESS: 1635 Faraday Av« Carlsbad, CA 92008 PHONE: (76O) 602-2741 mWORD»OOCfflCHKLSTVW*lno Wtf BuUng Pttnctet* CUM Form KF-doe 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (76O) 6O2-2720 • FAX (76O) 602-8562 2ND/ o a BUILDING PLANCHECK CHECKLIST RETAINING WALLS 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow B. Existing & Proposed Structures (dimensioned from street) 'C' 2. Show on site plan: A. Drainage Patterns - B. Existing & Proposed Slopes — C. Existing Topography - 3. Include on title sheet: tAr*!§ite Address (location and height) ^ Import/Export (Grading Permit and Haul Route Permit may be required) Q Q 4. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by:Date: MISCELLANEOUS PERMITS 5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. A separate Right-of-Way issued by the Engineering Department is required for th« following: Please obtain an application for Right-of-Way permit from the Engineering Department. Pagel Kw.MOM 3"octi o o o I i n Plan Check No. CBOoO Address Planner Paul Godwin Phone (760) 602-4625 Type of Project & Use: Sfft-fld. uJall Zoning: P"£ General Plan: Net Project Density: Facilities Management Zone: DU/AC CFD 'in/nut) #_ Circle One Date of participation:Remaining net dev acres: (For non-residential development: Type of land used created by this permit: ) Legend:X Item Complete Environmental Review Required: DATE OF COMPLETION: YES Item Incomplete - Needs your action NO TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: NO NO Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES CA Coastal Commission Authority? YES If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. H:\ADMIN\COUNTER\BldgPlnchkRevChklst I I I I Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: J 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. I 2. Provide legal description of property and assessor's parcel number. Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: I I | | 2. Accessory structure Front: Interior Side: Street Side: Rear: Structure separation I M I 3. Lot Coverage: Required Required Required Required setbacks: Required Required Required Required : Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown 4. Height:Required Shown I I 5. Parking: Spaces Required Guest Spaces Required Additional Comments Shown Shown >A& Elan IS \t\ aa £ &LJ a T"£ . Labg• i I,.TJ i ' . v)CiflftTS . JQ-y ci\mcniiQn5. _^^___ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst MINIMUM REQUIREMENTS FOR Retaining Wall/Sloping Backfill San Diego Area Chapter International Conference of Building Officials CvltiMd Chuta Vtea. Conwdo M Uw. El C^en. B C«n«e, EneMUk EMondUo, IrnpwW BMOL U M«H. Lvrnn Qnm. NX** C*. OnmU* KM*. S*t Otop C*y. Swi D»go County. Sm UVOM. SMN. HIMBMtfLTmajM. Vbu CHAPTER POLICY 222 Novtmbtr 1992 Construction of retaining walls, except those less than three feet high and not supporting surcharge, requires a permit and is regulated by local building codes. This chapter policy outlines requirements for re- taining walls with sloping backfill. Chapter Policy 221 covers retaining walls with level backfill. Contact your local building department for infor- mation on how to obtain a permit for a retaining wall. I. INSPECTIONS Inspections must be performed during several phases of construction. Please call for inspections at the following times: A. When the footing has been dug with the steel tied securely in its final position, and the si te is ready for the concrete to be placed, a footing inspection is needed. B. Amasonrypregroutinspectionisrequiredwhen the block has been laid and the steel is in place, but before the grout has been placed. 1. If cleanout holes are used, block may be laid to the full height at the grout pour before calling for the pregrout i nspcction. Grout shall be placed in a continuous pour in grout lifts not exceeding 6 feet. 2. If cleanout holes are not used, a masonry pregrout inspection is required prior to each grout pour. Block cannot be laid higher than the grout pour. Note thatcleanoutsare required for all grout pours over 5 feet in height. C. After grouting is completed and rock or rubble wall drains are in place, but before earth backfill is placed, call for a backfill/drainage inspection. D. When all work has been completed call for a final inspection. tt WALL HEIGHT Wall height is measured from the top of the footing to the top of the wall. Wallsnot shown in Tables Aand B on page 2 must be designed specifically for the existing condition. The walls shown here are designed to retain earth banks from level to a slope of 1 horizontal tol vertical (sloping surcharge). No building foundation, driveway, or other loading on the upper level is allowed within a distance equal to the height of the wall. m. BLOCK All block must be type "N" grouted solid with ' f'M« 1,500 pri. IV. MIX REQUIREMENTS Note that tat of plastic cement t« not permitted in retaining walls located in Seismic Zone No. 3 or 4. A. The concrete mix for footings must meet a compressive strength of f'c - 2,000 psi minimum, or the following proportions by volume: 1 part Portland cement 2V, parts sand 3V, parts Y4-inch maximum-size gravel 7 gallons of water maximum per sack of cement B. The mortar mix must have a compressive strength equal to 1,800 psi minimum. One possible mix contains the following proportions by volume: 1 part Portland cement 3V, parts sand V4 part hydrated lime or lime putty C. Grout must have a compressive strength equal to 2,000 psi minimum. One possible mix contains the following proportions by volume: 1 part Portland cement 3 parts sand 2 parts pea gravel (*/B-inch aggregate) Add water until pouring consistency is achieved without segregation of the grout constituents. Rod or vibrate immediately. Rerod or revibrate grout about 10 minutes after pouring to ensure solid consolida- tion. Stop grout 2 inches from top of masonry units when grouting of second lift is to be continued at another time. Note: All cells mutt be filled solid with grout. V. MORTAR KEY To insure proper bonding between the footing and the first course of block, a mortar key must be formed by embedding a flat 2x4 flush with and at the top of the freshly poured footing. It should be removed after the concrete has started to harden (about 1 hour). A mortar key may be omitted if the first course of block is set into the fresh concrete when the footing is poured and a good bond is obtained. VI. WALL DRAINS Wall drains (four-inch-diameter) must be placed at 6-foot intervals along the length of the wall and located just above the level of the soil or paving on the front face of the wall. The drains may be formed by placing a block on its side at 6-foot intervals, by leaving out the mortar in the vertical spaces between all the blocks (head joint) in the first course above the soil or paving on the front face of the wall or by any Nov«mbar1»2 San Diego Area Chapter * ICBO • Chaptar Policy 222 Paga 3 of 4 Figure I/Type I retaining wall with sloping backfill Concrete block 2" minimum to - > 6" maximum i • 2-#3 bars typical 3" clear typical Lap splice (See Section VIII.) Slope of retained earth (given as horizontal run to vertical rise) Horizontal steel (See Section VIII for applications.) Wall thickness 6" when T»A 8* when T-B 2" clear Reinforcing steel/ R Gravel backfill 12" wide Mortar key (see section V.) 12" minimum concrete depth. 12" minimum into natural ground or approved compacted fill Note: A minimum of 7 feet must be provided horizontally from the toe of the footing to daylight where the ground slopes away from the base of the wan. By:. City of Carlsbad Engiriooring Department BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CB BUILDING ADDRESS: PROJECT DESCRIPTION: Retaining Wall ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. Date: DENIAL Please see the attached report of deficiencies marked with LJ. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By:.Date: By:.Date: By:.Date: ATTACHMENTS D Right of Way Permit Application ENGINEERING DEPT. CONTACT PERSON NAME: MICHELE MASTERSON City of Carlsbad ADDRESS: 2075 Las Paimai Drive PHONE: 1619V 438-1161. Ext. 4315 P:\POC1\CHKLST\WAU. 2O75 Uas Paimas Dr. - Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894 cirr PLANNING DKFAKTMENT J dc Y-=r-Jo