Loading...
HomeMy WebLinkAbout2330 FARADAY AVE; ; CB011214; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04/12/2001 Commercial/Industrial Permit Permit No: CB011214 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 2330 FARADAY AV CBAD Tl Sub Type: 2120612900 Lot#: $6,000.00 Construction Type: Reference #: IPITEK ACCESS CONTROL INDUST 0 NEW Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: SDA SECURITY SYSTEMS SAIKHON DIANE TR 2054 ST ATE ST SAN DIEGO CA 92101 619 239-3473 8456 WESTWAY DR LA JOLLA CA 92037 APPROVED 03/30/2001 MDP 04/12/2001 / Total Fees: $134.93 Total Payments To Date: $44.78 Balance Due: $90.15 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Inspector: $68.89 $0.00 $44.78 $0.00 $0.00 $1.26 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF PFF (CFO Fund) License Tax License Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) PLUMBING TOTAL ELECTRICAL TOT AL MECHANICAL TOTAL Master Drainage Fee: Sewer Fee: Redev Parking Fee: Additional Fees: TOTAL PERMIT FEES FINAL APPROVAL $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $0.00 $0.00 $0.00 $0.00 $0.00 $134.93 Date: / (.,.. 3 b ,,.. O / Clearance: ____ _ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been aiven a NOTICE similar to this or as to which the statute of limitations has previously otherwise expired. V I FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHECK NO. ~ ~ \ <-L c.( CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. Co rcex> Plan Ck. Deposit l l C..C, 7 ~ Validated By , . 1rytf P Assessor's Parcel # Date t{ll{ G f Business Na.!IU! {at this address) .J,, f,n= < Lot No. Subdivision Name/Number Existing Use Unit flJo,-,., :}4:)y Phase No. Total # of units 03/30/01 0002 Oi O? Proposed Use CGP 44.:78 -D-e-sc-r-ip-t-io_n_p_f_W_o_rk ________________ S_O_. _F_T_. ______ #_o_f_S_t_o-ri-es ________ #_o_f_B_e_d_r_oo_m_s ______ #_o_f_B_a_t.,..h-ro_o_m_s __ , !--O.f:V-:1~6, /Jt,fl~.,J,11-fl_':c~. f.fl .. !Jcet."JJ, Gl~[/\uL ;2.:. qOfffACT.PJ:;RSON {lf·d•ffetent fr9m-~pplmaot) . · Name Address City State/Zip Telephone# :ii-• .' . J'ROJ'ERTY OWNER · : ".,.,, . ~ , ' " , . , Name Address City S.tate/Zip Telephone# :5,. ... QQr,IT.RACTQR;'.,CONIP-Al\!VJ•1'~MI;' .. ·,,, ', • ,v ,,,, '~ ·"'","" ,,, ··-·: ..... ¥ .... -, ..,.,..,,_...,..,,..,,,, ,,, , ..,. ,,,, ',. > .-..... ~ . ,.v (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemptio • Any violation of Section 7031.5 by any applicant for a permit subjects the apJJlicant to a civil penalty of not more than five hundred dollars [$500)). Q. <2t:..-..i1t,r J --... ,,. 1-1-S-· ~·--t~ c. c,i, o; G61 J -tJ-'Jt> Address City State/Zip <" Telephone# State License # J"/ Sb ~f License Class C? CI~ t.f .:f ( City Business License # ;J'1 / J 0 Designer Name Address City State/Zip Telephone State License# _________ _ :6 •.. ;wo.fi1.<~i!si.c0MP~N.s~r1.o"N· . . . . . · · · · ····· ·"· · · · I · ..... •• Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of t'>9 work for which this permit is issued. [ij/ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's comper:isation insurance carrier and policy number are: / / Insurance Company Af"k'/1,4,.1 t°it-1i.f',.11[tlfc" J:,tJ. L-0. Policy No.?Oo2wcooo 91:/tJ -oo Expiration Date / / O') (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure worke s' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($1 0Q 00), · add" · to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE'----¥-~~--~~-'----------------DATE j/lJ/ O/ . 7~. ~-QW~ltfl~!-!!LQl'.!!.Qi;C,_1,AJtA'f!Qr,I . -·· ......... ,_ . · "· ~-: .... _ ., , . ..,:·::_ ..... ~ ___ ;,_._, ·, .. ·~_·:.:_ :.,.,_ .. , .. " .. -. ·"' ·. 'w <H ,,_,' I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number):. _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address / phone number/ type of work):, _______________________________________________________ _ PROPERTY OWNER SIGNATURE ______________________ _ · cbfeP~t;I\: 1111s sEc;rioN, FQEi: if<JN·RESJDE.NftA.!, 131,1_11;pil'tG ,~EflM!J§;QW!eY ...• ·-· .• --; ~"' ',,.,' , ,' ' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. is..:.:-'9"§rfsi'f}:Q"c,:t,QN'.Le:Nf?J.NG)\q~~CY-: :· '~ ~ ~ ~ ~ ' .. ". q . ------:·~--· ". : .. :·.·--_,·.· ... : .: • : • I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any lime after the work is co need for riod of 180 days (Section 106.4.4 Uniform Building Code). DATE _:r=/..__.7/..,__/_o"-/ ____ _ WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request , -~ ;.. : :-. r:· :.: -:-;: . :. Permit# CB011214 Title: IPITEK Description: ACCESS CONTROL i=or: 11 /29/ioo 1 Type:TI Sub Type: INDUST Job Address: 2330 FARADAY AV Suite: Lot 0 Location: APPLICANT SDA SECURITY SYSTEMS Inspector Assignment: TP --- Phone: 7604381010 EX 3241 Inspector: _L_ D Owner: SALOUR MICHAEL M LIVING TRUST 09-09-86 .. Remarks: GO TO 2320 FARADAY AV Total Time: Requested ~x: JOEL 1 ¥1: , ...... ~ '\ r. r~-.. ~'· .!: O --• M • I ! i-erjtefed-By:\-CHRISTINE CD Description 39 Final Electrical Act .. Cornni~r:i\t~1 li_:;.,"}_/~J, I Associated PCRs Inspection Histo')' . :.·.:,··:1:;:;T : Description Act ·1nsp· Comments Date 10/23/2001 34 Rough Electric NR TP ND FIRE APPVL . \ .. ,' EsGil Corporation In Partnership with Government for Building Safety DATE: 4/10/01 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 01-1214 PROJECT ADDRESS: 2330 Faraday Ave. SET: I PROJECT NAME: Ipitek -Controlled Access Hardware D APPLICANT D~ D PLAN REVIEWER D FILE [g) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. CJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [g) Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: .. Date contacted: (by: ) Fax #: Mail Telephone Fax In Person 't, D REMARKS: By: Doug Moody Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/2/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ; City of Carlsbad 01-1214 4/10/01 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: 01-1214 DATE: 4/10/01 BUILDING ADDRESS: 2330 Faraday Ave. BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Access Hardware NIA City Valuation ' Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1994 use Building Permit Fee l•I 1994 use Plan Check Fee Type of Review: 0 Complete Review D Structural Only D Repetitive Fee ==8Repeats Comments: D Other D Hourly ..._ ___ __.I-Hour(s) * Esgil Plan Review Fee ($) 6,000 6,000 I $78.581 $51.071 $40.861 Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB d / -/ ~-/ Lf DATE --1-:1~1/rob'--,1~!0~1 __ "RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR < < $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE FAIRE COMPLETE OFFICE BUILDING OTHER_,..._O ___ t ....... \L..__{D ...... 9+-'-B.....,.o~xd.-\A-),......C\-{..._f""""', ___________ _ tit_ PLANNER DATE __ i-L..,. ~U~<;/2~0....£.,..,1/ __ Docs/Mlsforms/Planning Engineering Approvals Carlsbad Fire Department 011214 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report: _04_1_03_12_0_0_1 -------- .Building Plan Reviewed by: Name: SDA Security Systems Address: 2054 State Street City, State: San Diego CA 92101 Plan Checker: Job#: 011214 ------- Job Name: lpitek Bldg#: CB011214 ------------------ Job Address: 2330 Faraday Avenue Ste. or Bldg. No. ~ Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments ·attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments , attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 011214 2nd FD File# 3rd Other Agency ID • ' r ,.,! IPITEK Z330 AND 2320 FA.BADAY A VENUE Carlsbad, c4-. 92008 ~ecqrity Locking lfardware Submitffll Submitted By; SDA Security Systems, Inc. Contact: Paul Stanzione 2054 State Street San Diego" CA. 92101-1780 License #245668/Type C7,C10 • IPITEK Security Locking Hardware Submittal Equipment List Description Model# Control Panel Northern N-750 Card Reader Northern PR-MINI-PROX Touch Sense Bar Adams Rite 8611-EL Rim Strike Adams Rite # 880 I-EL • Mecanical Push Bar Adams Rite# 8611-36 Power Supply Adams Rite # 29-01-04 • N-750 • Access Control / Burglar Panel The basic configuration options of the N-750 center around four simple features. These four simple features are building blocks engineered for complete flexibility, so a system can be tailor-made for your application . Security Points -A security point is simply a single point of protection. For your security needs it might be a contact switch on a window or a motion detector, or even the lock control on a door. And with addressable points, the activity and condition of individual security points can be identified. Zones -A zone is one or more security points grouped together in an electrical circuit. For example, the doors, windows and other security points in a conference room could be identified as a specific zone. Areas -An area can either be classified by a group of security points, or by one or more zones. You can control your areas individually as well as grouping them together. Partitions -The N-750 brings you true partitioning in a single system. A partition is an area or group of areas config- ured into an autonomous system. For example, a management company for a high-rise can invest in one N-750 system to provide individually programmed, monitored and billed access control and security services to each of its tenants. In this type of environment, the cost savings, maintenance and reliability of the N-750 is years ahead of any other technology. What used to take a number,of systems, multiple vendors, and a variety of service and monitoring contracts, now can be handled with one system from one company. 5007 South Howell Ave. tel: (414) 769-5980 Milwaukee, WI 53207 fax: (414) 769-5989 web site: http://www.nciaccess.com I ,· -1· .Apce_ss Control / B,La:rglar -Pa.nel N-750 SBUS 1 1'0,J.'!I!! ''!4-· '·-11· 1-1' _.., .. &,.sEii.Js:2111:~HI-!"!"--. ,! .'~ N-75'9~ADM ·An~ 26i32 or.34'blt: · Wleg~nd_-Reader f{~ad,~r Mohitor Contact'/, Door-Zone, -Any-26,-32:or-34'-hlt Wlegarid'Reader. TOUCHPADS/ CARD. 'READERS (max. 24 per system} 'ZONE-· ~----..,. ;EXPANO.ERS PRINTER' F~E1t!Ji'e$ for dlrect·connectlon to ACAS'Soft.wiirE! • 16 ·supervised, pr9grammable zones, e:xp~dable to 400. • I.;ig4tfrue pllfl;itim;is with up to ejght areas per partition ((54 possible areas). • tJ p to 1 ;800 users ot cards. -• High speed RS-485 bus -to connect totichpads, i9ne-expanders and .. othef accessories, . . ' -. N-1so~ss~ ' i· N-750-ZONE t -~ ~]AND/DR. Adds 128 Zones Ad'-d-s-.,,..64_H ___ a-rd_w.,..lre_d_Z_o.,nes Use.wlth·N,750-SS · ·a inax. .. Smart Sensors a max: • Up to· 24 tg(lchpads an<:1/o_r card readers. -~ 50 time Schedujes witlpO ranges per schedule .. • Auto or manual:lo\!kliml9ck. · • Local an'd GlobaLanti".passback. • Puress feature. ",', UL Listings • UL 294 Access Control • ULGradeA • UL 365 Police-Connect • UL 609· Local Burglary • UL 611 C.S. Burglary UL 636 Holdup Alarm Units UL681 B:,mkBurglar-$yste __ UL 864 Comm. Fire C.S. • UL 985 Household Burglary ·· •. UL 1023 HouseholdBurglary. • UL 1076 Proprietary Burglar;y • UL 1610 C.S. 'Burglary • UL I635 Digital Burglary System • ULC Res./Cotnm. J3urglary • FCC Part 15 • FCC Part 68 DOC CS-03 • CSFM Res./Com_m/Fite Panel, ·Specifications. .Ordering. I , Dln,~n$10ns ....... 151'W x '20"H x 3"D Weight ............... 17 lps: Power .. : •. ! .......... ; 18VAC, 60Hz, 50VA Temp~raturb ...... 32° to 120" F ' . 0° to-.49°'.C 1 Humidity;._ .......... 85% non-col)densing •~uartt 1-80-0-323~4576 :N-750 ... : ............. Security/Acce(ls Control panel N.;tso-PA'/T .. , ...... Progr<1minl11g ~ Access Touchpad lq~. the N-750 , . N,-750-ADM ........ Dqor Access·Moaul~,fqr-the - N-750- . N-750-Pi '.,., ......... Serlal/Paralleil:!ntei:tace for Pr.infer or-D[rect Connect to N-750 N-750-ACAS ...... Adminisiratlqn ~oftware for ·the,N-750 N.:750.:Sk_ .......... .'Remote Upload/Downlpad, Software for.the N-750 ,, N-750-APS ......... 12VDC A(!xlliary f?o~er Supply for the N-750 · N-750.:APS-24 .... 24VDC Auxiliary Power Supplffor.the N-750 N;750-ZONE ..... .'64 Zone Expander for the N-750 N7 750-$S .-.......... Smart Sensor for the N-750 & N-750-SS~ N~750-SSE ......... 128 Point Expander.tor the N-750 lf:75.0.4JPl!.M ._ .. i.;;Dual Phone Line-Module for . theN-750 N~750-BELL ....... Bell Supervision for the _N-750 5007 South Hqweff Ave. Milwaukee, w1· 53207 , t~I: (41'4) 769-5980 fax:. (4-14) 769-5989 web site: http:/iwww.ncic!<:cess.com • • • Also available for a Midpanel door design CERTIFICATIONS: @Life-Safety l..isfing ANSI/BHl'vV\AJ56.3 Grade I caJifornia State Fire Marshall New York Gty MEA* •Consultracto,y for specific number BHMA TYPE6 Narrow Stile Concealed Vertical Rod Exit Device 8600 Series UFE-SAFE1Y ED-6 0 I v Patented top latching mechanism interlocks door to frame TTop and bottom adjustable steel rods v Pushbar clad, not plated, in ,:1 variety of finishes v Easy to install y Clean, unobtrusive design V Strong, durable construction for a high level of security 260 Santa Fe Street Pomona, California 91767 (BOO} 872-3267 Fax:(800) 232-7329 www.adamsrite.com • • Narrow Stile Concealed Vertical Rod IEJKit DeYice ANSI/BHMA Gradel Handing Device is non-handed. Lever Entry Trim is field reversible. Pushbar Length Standard Sizes: Dimensioned for 30", 36", 42" & 48"openings. Standard width bars can be field cut to the next smallest opening width. Projection 2-5/8" when fully projected, 1-5/8" when dogged. Door Thickness Suits 1-3/4" standard, up to 2-1/4". Device requires modification when used with cylinder in doors over 1-3/4·. Stile Wall Doors with stile walls other than I /8" require modification. Stile Width Minimum 2" Stile. Fits Narrow, Medium and Wide Stile aluminum doors. Bar Height Adjustable from 30" to 44". Door Height Standard unit at!justable for doors up to 66 • above the selected bar height. For doors over 66" above bar height; up to Jo·, use 8655 Tall Door Kit. Materials Pushbar made of extruded aluminum, clad or anodized in a variety of finishes. Dogging Standard dogging with hex key or optional cylinder dogging. Electric dogging available. Fasteners Standard self-tapping screws. Stril<e Made of hardened steel. Supplied. Cylinders (order separately) Cylinder x Fixed Pull: (Function 03) Accepts any standard Mortise cylinder with MS®cam. Entry Lever or Thumbturn: fFunctions08,09, 11, 12j Accepts any standard diameter Mortise cylinder with MS® cam. Accommodates cylinder lengths from I" to ,J-J/4". Warranty Two year limited . 313 Dark Bronze Anodized 335 Black Anodized 628 Satin Aluminum US3 Bright Brass US4 Satin Brass US9 Bright Bronze US10 Satin Bronze 10B "Oil-Rubbed" Bronze (Trim only) US32 Bright Stainless US32D Satin Stainless Consult -factory for speda/ finishes. () Bolts and Strikes Pushbar Dimensions Bottom Bolt The patented top latching mechanism utilizes a rot.ating Top Bolt which deadlatches around the Header Strike, interlocking the door to the frame. Supplied with Standard or Fire- rated Header Strikes. The hexagonal, hardened steel Bottom Bolt works in harmony with the Top Bolt Standard Strike Fire-Rated Strike Fully Projected 8675 Midpanel 0 Dogged The Concealed Vertical Rod exit device is also available for use with a Midpanel design. Consult factory for applications . ,1: t • 1t Order by adding suffix to Exit Device in place of hyphen or by separate model number. • • u oammummo urn D OEIID D mmo [IDO A.switch in the exit device pushbar mounted on the hinge end. Switch can be used to aaivare signal light. horn, monitor or other devices. Most common application is to release maglock when pushbar is depressed. Switch can be wired for normally open or normally closed depending upon application. Can be retrofit in field to existing exit device. Dual switch version offers redundancy as required by some building codes or the option of operating a second signaling device. Specify by adding "M1 "or "M2" after exit device model number. Monitor Kits for upgrading any 3000 or 8000 Series device: 91-0897-01 -Single Switch 91-0897-02-Duaf Switch The El option uses a solenoid mounted in pushbar for instantaneous unlocking and locking of the exit device from a remote location or access control device. Because electrical operation of device is fail-secure, this option can be used on fire-rated as well as life-safety applications. In the event of a power failure device automatically relatches. Requires the use of 29-0 I 04 Power Supply, which will power two exit devices. Specify by adding "EL" after exit device model number. Order 29-0104 Power Supply separately. Solenoid Specifications: 24VDC -12 Amps Inrush/. 12 Amps Hold Solenoids are rated for both intermittent and continuous operation. Also see 4611 Power Transfer: 00000 oamrnornrno moo 00000 oamommo moo DDDDIIJO[l]l[IOO Dom O[IJ Dummy pushbar with no latch mechanism but with either a single or dual monitor/signal .switch. Most common application is in conjunction with a maglock where bar is used to turn off magnet and allow exitfium building. Dual switch version allows redundancy where required by code or the operation of a signal device along with maglocl<. Specify door type and width when ordering. Available in all exit device finishes. The 8099-00 is also available as a non-operating dummy for doors not requiring an exit deice. but where matching trim is desired. Specity door type, opening width and finish to be matched. 000710 8600 02000 /\DNv!S RITE MANUFACTURING CO. This option emits a loud alarm to notify management of unauthorized exit. Will not alter the Life-Safety characteristics of the exit device in any way. Control of the alarm is by use of a key in any standard Mortise cylinder with MS©-cam to arm, disarm, delay or reset the alarm. Red letters on the bar give a "hands off' warning to deter accidental actuation. uoooooom oornooom mm Four AA alkaline batteries power twin horns to create a piercing 95 decibel noise for two minutes (or until disarmed) when pushbar is depressed. Beeps to signal need for new batteries. o 0000 moom mrn can be connected to external horn for louder or remote signal. Remote monitor LED light can also be wired in. as can a door position proximity switch. Also accommodates an external delay .switch, such as an outside key switch or pad, to allow authorized ent:Iy. Uses rechargeable nicad batteries connected to 12-24 Volt AC or DC source. Each bar has its own battery backup system . Minimumopeningwidth: 36" n n nan nnnn n n ma an n o n no o an ono no n nano n n n n For management control of dogging. Any standard 15/16" to 1-1/8" long Mortise cylinderwith MS® cam can be used in a pushbar prepared at factory with Cylinder Dogging kit. Cannot be used with Alarm or EL option. Specify by adding ·co· after exit device model number. n n non:nnnn n n n non nan ·nnonnonnnonn The "ED" option uses a holding magnet to keep the pushbar depressed and the latch open. This gives a lower profile exit device, resulting in less damage. It also results in more quiet operation. On fire-rated devices, it must be wired through the fire alann system. All devices are available in 24VDC. drawing .5 amp, allowing them to operate with a simple transformer and rectifier: The "EDM", which includes a microswitch in the pushbar, is fdeal for use with automatic operators when security is not an issue. (Use "EL" with security devices such as card readeror key switches.} Specify by adding "ED" or "EDM" after exit device model number. • • CERTIFICATIONS: @Life-Safeq, Listing ANSJ/BHM4.Al56.3 Grade I California State Fire Marshall New York aiy MEA* •consult facto,y for :speofic number () BHMA TYPE4 Narrow Stile Rim Exit Device For Aluminum Doors 8800 Series UFE-SAFETY Features: V Patented "Starwheel" Bolt interlocks door to frame v Pushbar is anodized or clad, not plated, in a variety of finishes T Easy to install v Unobtrusive design for clean sight lines TStrong, durable construction for a high level of security 260 Santa Fe Street Pomona, California 917 6 7 (800) 872-3267 Fax:(800) 232-7329 www.adamsrite.com • • Narrow Stile Rim Exit Device ANSI/BHMA Grade I Handing Device is non-handed. Lever Entry Trim is field reversible. Pushbar Length Pushbar Length Dogging Standartl dogging with hex key or optional cylinder dogging. Electric dogging also available. Fasteners Standard self-tapping screws. Strike 313 Dark Bronze Anodized 335 Black .Anodized 628 Satin Aluminum Standard Sizes: Dimensioned for 30". 36", 42" & 48" openings. Standard width bars can be field cut to the next smallest opening width. Made of hardened steel. Standard and narrow version supplied with exit device. US3 US4 Bright Brass Satin Brass Door Thickness Suits l-3/4" standard, up to 2-1/4". Stile Width Cylinders (ortler separately) Cylinder x Fixed Pull: (Functions 03) Accepts any standartl Rim cylinder. Entry Lever or Thumbturn: (Functions 08, 09, 11. 12) US9 Bright Bronze US10 Satin Bronze 10B "Oil-Rubbed" Bronze (Trim only) Minimum 2" Stile. Fits Narrow, Medium and Wide Stile aluminum doors. Projection 2-5/8" when fully projected, 1-5/8" when dogged. Accepts any standard diameter Mortise cylinder with MS® cam. Accommodates cylinder lengths from J" to 1-1/4". US32 Bright Stainless US32D Satin Stainless Materials Pushbar made of extruded aluminum, clad or anodized in a variety offinishes . Starwheel Bolt Warranty Two year limited. (1 J When door closes, the interlocking noseguard and Starwheel bolt close around tl1e strike. The deadlocl<lng slide springs over, locking t11e StarwneeJ bolt to the stnl<e. [2] When pushbar is depressed, the deadlocking slide moves back, allowing the door to unlock from the strike. This unique interlock provides sofid security and prevents jamb spreading. Strikes Standard strike and narrow version for centering doors in4"jamb. ~ ~.815-l l--1.ss--l =;Tr-2.75 2.00 J -I .so I- 0 Consult facto,y for special finishes. Pushbar Dimensions r--2-5/8 T· 2-7/16 --=::1:D:J j_ '----'. Fully Projected Dogged Removable Mullion • 3890 Allows the use of Rim exit devices on paired doors without narrowing the doors. Provides higher security and better traffic flow than paired doors with Vertical Rod exit devices. Available in anodized 313 and 628. Specify door height when ordering.