HomeMy WebLinkAbout2333 MICA RD; ; CB080013; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-20-2011 Residential Permit Permit No: CB080013
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Vaiuation:
Occupancy Group:
12/29/2010
# Dwelling Units:
2333 MICA RD CBAD
RESDNTL
2132820900
$453,008.16
Sub Type:
Lot#:
Construction Type:
Reference #:
SFD
35
VN
CT040016
Structure Type: SFD
Status:
Applied:
Entered By:
Issued:
Bedrooms: 4 Bathrooms: 4.5 Inspect Area:
Project Title: VIRIDIAN-LA COSTA GREENS-PH$ 7 Orig PC#:
PLAN 4: 4194 SF LIV-826 SF GAR.-172 SF PORCH//88 SF
DECK
Plan Check#
Applicant:
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE 92618
949-341-1289
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
$1,785.69
$0.00
$1,160.70
$0.00
($92.86)
$45.30
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$4,878.00
D3/4
$182.00
$0.00
??
Owner:
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE
CA 92618
949-341-1289
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
ISSUED
12/27/2007
JMA
Plan Approved:
12/29/2010
PY
PC060023
PC070086
$0.00
$190.00
$4,492.00
$3,122.05
$8,244.75
$0.00
$0.00
$0.00
$2,286.80
$0.00
$0.00
$223.00
$60.00
$103.00
$0.00
$0.00
$0.00
$0.00
$2,018.00
$125.00
??
$28,823.43
Total Fees: $28,823.43 Total Payments To Date: $28,823.43 Balance Due: $0.00
Inspector:
FINAL AP
2 Date: Clearance:
NOTICE: Please take NO pproval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposttion of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f x i n f h" h v r vi Tl hi r whi h h f limi i n h rwi
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
12-29-2010
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW100467
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
2333 MICA RD CBAD
SWPPP
2132820900
CB080013
VIRIDIAN: PHS. 7
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE
CA 92618
949-341-1289
Emergency Contact:
GARY BOUCK
949-246-7922
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 35 Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE
CA 92618
949-341-1289
ISSUED
11/23/2010
JMA
12/29/2010
1
M
$0.00
$208.00
$0.00
$208.00
Total Fees: $208.00 Total Payments To Date: $208.00 Balance Due:
FINA . APPROVAL
OATF.Jl/1 ~ti_ CLEARANCE__~_
l:ilGNATURE _ _ _ ____ _,
$0,00
City DI Carlsbad
~ ·; Final Building Inspection
~ --,~,~-~
r
Dept: Building Engineering Planning CMWD St Lite Fire I 2 2011
Plan Check #:
Permit #:
Project Name:
PC070086
CB080013
VIRIDIAN-LA COSTA GREENS-PHS 7
Date: 09/09/2011
Permit Type: RESDNTL
Sub Type: SFD
PLAN 4: 4194 SF LIV-826 SF GAR.-172 SF PORCH//88 SF
Address: 2333 MICA RD Lot: 35
Contact Person: Phone:
Sewer Dist: CA Water Dist: CA .... , .................................................................................................................................................... .
Inspected ~ Date 9[~/_u By: ~ 2 :::::, Inspected: Approved: ~ Disapproved: __
Inspected 7 Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __ ...........................................................................................................................................................
Comments: _____________________________ _
City of Carlsbad Bldg Inspection Request
For: 11/30/2011
Permit# CB080013 Inspector Assignment: PY
Title: VIRIDIAN-LA COSTA GREENS-PHS 7
Description: PLAN 4: 4194 SF LIV-826 SF GAR.-172 SF PORCH//88 SF
DECK
Type: RESDNTL Sub Type: SFD
Phone: 9492467922
Job Address: 2333 MICA RD
Suite: Lot: 35
Location: Inspector:
OWNER TAYLOR MORRISON OF CA, LLC
Owner: TAYLOR MORRISON OF CALIFORNIA LL C
Remarks:
Total Time:
CD Description Act Comments
19 Final Structural ~ 29 Final Plumbing
39 Final Electrical t-49 Final Mechanical
Comments/Notices/Holds
-----
Requested By: GARY
Entered By: JH
Associated PCRs/CVs/SWPPPs Original PC# PC060023
SW100462 FINAL VIRIDIAN: PHS. 7;
SW100463 ISSUED VIRIDIAN: PHS. 7;
SW100464 ISSUED VIRIDIAN: PHS. 7;
SW100465 FINAL VIRIDIAN: PHS. 7;
SW100466 FINAL VIRIDIAN: PHS. 7;
SW100467 ISSUED VIRIDIAN: PHS. 7;
lns(:!ection Histoi:y
Date Description Act lnsp Comments
08/24/2011 39 Final Electrical PA PY EMR
07/19/2011 23 Gas/Test/Repairs AP PY
07/11/2011 17 Interior Lath/Drywall AP PY
07/11/2011 18 Exterior Lath/Drywall AP PY
06/30/2011 16 Insulation AP PY
06/28/2011 84 Rough Combo AP PY
06/16/2011 13 Shear Panels/HD's AP PY
06/07/2011 15 Roof/Reroof AP PY
Inspection List
Permit#: CB080013 Type: RESDNTL SFD
Date Inspection Item Inspector
12/01/2011 89 Final Combo
11/30/2011 89 Final Combo
11/30/2011 89 Final Combo PY
08/24/2011 39 Final Electrical PY
07/19/2011 23 Gas/TesVRepairs PY
07/11/2011 17 Interior Lath/Drywall PY
07/11/2011 18 Exterior Lath/Drywall PY
06/30/2011 16 Insulation PY
06/28/2011 84 Rough Combo PY
06/16/2011 13 Shear Panels/HD's PY
06/07/2011 15 Roof/Reroof PY
06/06/2011 15 Roof/Reroof PD
06/03/2011 15 Roof/Re roof TP
06/02/2011 15 Roof/Reroof PY
04/12/2011 81 Underground Combo PY
03/31/2011 21 Underground/Under Floor PY
03/31/2011 22 Sewer/Water Service PY
Thursday, December 01, 2011
Act
RI
RI
AP
PA
AP
AP
AP
AP
AP
AP
AP
CA
NR
NR
AP
AP
AP
VIRIDIAN•LA COSTA GREENS-PHS 7
PLAN 4: 4194 SF LIV-826 SF GAR.-172 SF
Comments
GMR
EMR
Page 1 of 1
✓/~lD/4/l/ f.ii(if,f:t 1Jspection and Testing, Inc.
Prw~-7 441 Commercial Way La Habra CA 90631
(562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026
REGISTERED INSPECTOR'S DAILY REPORT
TYPE OF
INSPECTION
REQUIRED
Job Address
0 Reinforced Concrete
Post Tensioned Concrete
0 Reinforced Masonry
0 Structural Steel Assembly
0 Post Tensioned Concrete
0 Asphz:lt
Type of Structure '::f(l , fT F'OJ, 0 i:::;A T1 O "'] ~ Architect
Subcontractor \JC-R...6,.UbO
TESTS PERFORMED
TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON SAMPLES
-I,-//
A 1):-)
INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TESliSAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS,
REMARKS ETC. INCLUDES INFORMATION ABOUT-AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED NUMBER, TYPE & IDENT. NO'S
OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS ELD MADE H.T. BOLTS TORQUED CHECKED, ETC.
CERTIFICATION OF COMPLIANCE
I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF
MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK
UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO
COMPLY WITH THE APPROVED PLANS, SPECIFICATION, AND
APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS.
SPECIAL TY NO. AGENCY
CONTINUED ON NEXT PAGE □ PAG
TIME IN TIME OUT REG. HOUR O.T. HOURS
Approved by
----:J...,,,__ __
Pro"ect Su rintendent
~I£-( f?tf-1 N
GEOCON
INCORPORATED
6960 FLANDERS DRIVE
PJM&~ 7 --C~ GEO TECHNICAL CONSULT ANTS
SAN DIEGO, CALIFORNIA 92121-297 4 ■ TEL 18581 558-6900 ■ FAX 18581 558-6159 Iii
FOUNDATION OBSERVATION REPORT
PROJECT NAME : -~/-'"'=e------'_G~IIZ_l!!::_e_v_;..s~_/._o_____c.6 _______ _
LOCATION : ____ L_o_r __ 3_S_.J) __ 3_b-'---------
FOUNDATION LOCATION (if not entire building}
PLAN FILE NO. PERMIT NOS :
3S: CJJ>o8oo 13
FOUNDATION TYPE :
D CONVENTIONAL
POST -TENSIONED
a~ oe>r O
• PU~SE OF OBSERVATION 37,; O
PROJECT NO. 06>.~o3 -S2. -~S
._; / 1 1 I -;z...o 1 1
0 ADDITIONAL OBSERVATION REQUIRED
fJ'jerify soil conditions exposed are similar to those anticipated
cf' Verify footing excavations extend to minimum depth recommended in soil report
D Verify foundation reinforcement complies with minimum recommended in soil report
D Jerify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report
[)" Verify footings have been extended to an appropriate bearing strata
0 Other --------------------------------------
• APPLICABLE SOIL REPORT: TITLE: --'U"""P_O_J\....:....:....7 F:" __ _,,G...,tE.=o=re"--==c'-u.C....:.'----#-/<i--""--'---n-----'-----"~'---• .......:......V,_,._.___,,.'---o_,= __ L.,. __ £--_o_"i_~ __
____ ,_,,,_e.. __ G;:___e:.;__u.::..___...J_s ___ /__c,_;:O::..;(p..._ _ _.________________ DA TE : ,,.,,, >.,... ~ J., Id) I ;to O {,
• SOIL REPORT RECOMMENDATIONS BASED ON:
Expansion Condition O VERY LOW O LOW O MEDIUM 0 VERY HIGH
Gf'Fill Geometry -----=3::..:S~.l~-~0,~1 _,,,;77~1 ~-+-~CA~~-r--=Te::!!=.L __ -~3:...!.7:__ _ _g~---------
□ Other :--------------------------------------
• MINIMUM FOUNDATION RECOMME~D TIONS: -p :JV.-
□ Footing Depth : D 12 Inches 18 Inches 24 Inches OTHER _____________ _
Footing Reinforcement: 0 No.4 T&B O 2-No.4 T&B O 2-No.5 T&B ~ost-Tensioned OTHER : _____ _
Interior Slab Reinforcement : D 6x6-10/10 D 6x6-6/6 D No.3@241nches D No.3@181nches Post-Tensioned
Slab Bedding Material and Thickness : ___________ _ Vapor Barrier :
Foundation Width : ----------------------------------
• OBSERVATIONS:
sf substantial conformance with Soil Reports (see "Purpose of Observation")
D Substantial conformance with Foundation Plans. Identify : --------------------
0 Other
OTE: IT IS ASSUMED THAT All FOOTING EXCAVATIONS Will SE aEANED Of LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOIL MOISTURE CONTENT WILL SE MAINTAINED
AELD COPIES TO GEOCON REPRESENTATIVE
«,:/:•
~ CITY OF
CARLSBAD
CIRCUIT CARD
B-36
Development Services
Building Department
1635 Faraday Avenue
760-602-2 719
www .carlsba dca. gov
1'HlS CAltDMUST BE FILLED OUT AND AYIIILAllL'E ,<.TTtlll SlllWlCE ec UlPMI:),IT fOR nm ROUGII INSPCCTION
Address: 2 '3?. \ MlCA Rf) Permit Numt>or: C JI)., d A Q/"'J I ~
Owner: ,, A" J .r~r lll {) h /) g/J' }Phooo: CilJ Q -~ l/} '/()(J -Area In Sq. Ft.
Contractor. Phone:
PANEL ....... ---·M ... o•••••-• '• ...... ...... , A.LC. VOLTS 0 WIRE
BKR WIRE MISC REC REC LTG MISC WIRE BKR LOCATION CKT SIZE SIZE TYPE Slo/.E T\'l'~ SIZE CKT LOCATION
7-D l 'L ~ ;o ~ \ 1/0 J.,/, -N\. f-lo,(\r\, 1 I • 2
w Iv ~ s <i< ~ '-10 A-it--?l>'>n<v 3 " 4
/;iM./11h 5 15 I ti tu 7 cf, lJ lf{) 6 Alv
~o,0 "-I <;..(") 7 1.< I;,., ' JO 5( /~ J lfD 8 ,A-'/v
\2,uL6' 9 ,< / L fl LJ .. '7 &, ~ 3 f Lf l~ i 1< 10 t.J\ . /br-;I\
971h '.'½ " 15 ;;J 1 .Ll II 1-, ln ( l( ~ 15' 12 /..1,A{.f,,,-
ito--t ~ 13 ,~ 14 i'k\ z 9 z 7 I fl-/ u /~ 14 HA-U-
I .. b ... I I IL/
,, J< rllbbrl. te.O 2,' 1-, 15 /{<( lJ. ll 16
C.~i( 17 ,.c Ii, ()A lo L.. 2.. 3 I /Li " Ir 18 iN\. hJsr'J,
fl,/) ,Ju<, /lW\ 19 !'5' /'1 '..,t. !j ' ,7 s I 11 ·~ J /C::: 20 1e,,J./,,....,
<z>br 21 1< t '1 ~ ,A /l/ ~. ,4 IC 22 ,::',41 j
se1 ,,;L, 23 ,C:: I '1 M IY e.. I§ 24 rA--IA
+lV\.1hi ~ ii 25 !-< I '1 ti ~ 26
' 27 28
29 30
31 32
33 34
35 ' 36
37 38
39 't 40
41 42
MAIN:0 zzr AMP BRK/FUSE O MLO Computed Load AMPS
SH Calculelion WOrltliiae( on beci<
BUS; AMP Branctl circuits required:
Servico enlr.inCll or leader conduCle>r<;: A) Lighting Circuits 220 -3/b), 4(d)
A) Si;ze; No. B) Type: D cu DAL B) Two Small Appliance Clrc1ills 210-11(e)
Ci Insulation: 0) Conduit Size: __ C) Laundry ClrC\ltt 220 -16(b)
Sentlce ground/bond: ffiu [)AL
D) Central Heating Equipm&nl 422 -12
A) Size: No. z._ B) Type: E) Baltlroom 210 -52(d)
C) Clamp location(s):
2S0-S0(c) Remarl<s: !9'UFER
D Water Pipe 250 -104
~~c 250 -52
GFC~tions 210 -e. 680 -70; / csrllly rhat &II terminations have been rorqut1d in acccirdance with manufactur11r's
:ithroom(s) ~hen insln.ic:sion~ and that th6 work shown on this circuil card represents tho full llxtent of
~&g,,/s) _ ydromasr,119e Tub tile work partormod under this pt1rmil.
. utdoors D D Owner
D Contra~~_$t&rJn l: AF~cted Gire. 210-12
edroom(s) D Signed · Date
B-36 Page 1 of 2
•
~·---------~~__._~~--
c ~ <<~,:;:> CIRCUIT CARD Deveto~:1:1~:i~:~~=:i ~ C I T Y O F B-36 1635 Faraday Avenue
CARLSBAD 760-602-2719
www.carlsbadca.gov
1'H1S. CA.JU) MU!iT BE FILLED Ot.rr ANO AVAILAbLE AT TU9 sEiVlt.f. JI,( UIPMENT r,of{ mn ROUGH JNSPBCTION
Address: Permit Number:
Owner: I Phono: Area In Sq. Ft.
Contractor: I Phone:
J)ANEL ··•···. "-. A.LC. VOLTS 0 WIRE
BKR WIRE MISC REC REC LTG MISC WIRE BKR LOCATION CK,-Si2E SIZE l'IPE SIZE. TY'E S12E CKT LOCATION
0,/0 /\ 1 7,) th l'., ,\. I z_,. ''., ZD 2 D..P
oJtA, 3 '1( ~ J/'-/(_ ~A -z..o 4 "-'• "° Ckill
fler 5 -Z,o / 7.,.. .... I& 'I Zo 6 "'"--· Da. .. , . ..--
7 U) / t. A )V ' 7,<.J B I ... -1A ..... M,c:.., .
Lh~n 9 U) I 2.-r .. ~ le l '.1,. -ui 10 ~ . .} G.r-i
ii) I z_,, r .. 'Z, /& ' Z-c ,2 11 ;J-{,,f'I r~n 11
tJv,,. · .. \ 11.." 13 Z,0 /7, u, i '-f I z__ . , JJ) 14 Di .J.1.,
Ne»"-15 z,u I l-c.... J I 3 fl • IA ,~ 16 f°AivJ t...,..
l\looll-17 IS 17 ~ /0 8 I" .. IC: ,e • , .. ~
lz.. '-~--' 18 1-5 /'-f r .. 11> ' 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 I 40
41 42
MAIN:□ z.u AMP BRK/FUSE O MLO Computed Load AMPS
SN Calcula/JOn Woricah&et on ~
BUS: AMP Branch circuihl required: SetviOG snlranca or1esdercontiuct~: A) Lighting Circuits 220 -3(b), 4(d)
A) Size; No. B)Type: D cu DAL Bl Two Small Appliance Clrc"lts 210-11(e)
C) Jnsulalion: O) Conduit Size:_ C) LaundryClrC1.lH 220-16(b)
Service gro"nd/bond:
~DAL
D) Central Heating Equiprn•nt 422 -12
A) Stze: No. 7 B)Type: E) Ball\room 210 • 52(d)
~•mp location(,):
2$0-S0(c) Remarks: UFER
D Water Pipe 250-104
~Rod 250-52 -:s
GFC~lions 2:10-E'., 680-'70:
~chcn
f cat1.lfy that eJI terminations heve been torqued in acccirdance with manufsc1urer·s
3throom(s) ins/fl.lczion:; and that the work shown on this circuit card represents thG full &xtent of
e:rtlarag,,ls) ~ ydrome5&a9e Tub tile work pBrformoci under this permil.
l]H!)utdoors D □Owner
AF~cted Gire, 210-12 0 Contracto$_~t~ •c
~droom(s) D Signed , :A . Date
B-36 Paga 1 of 2
l OT 3,5'
INSTALLATION CERTIFICATE CF-6R-ENV-01
(Page 1 of3)
Enforcement Agency:
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate
applicable to the portion of construction/or which they are responsible; alternatively, the person with chief responsibility for construction shall
prepare and sign this certificate for the entire construction. All applicable Mandatory Measures with check boxes require to be checked to e~ure
the mandato measures have been met.
Description of Insulation
1. RAISED FLOOR
Material: ________ .......,.....,----",_,.____ Brand Name: _____________ _
Thickness (inches): ____ -1-:::.f---l-.L---Thermal Resistance (R-Value}: ______ _
D §lS0(d): Minimum R-13 insulat10 in raised wood-frame floor or equivalent U-factor.
2. SLAB FLOOR/PERIMETER
Material: _________ -----lf+-cH'----1'1---.Brand Name: _____________ _
Thickness (inches): _____ ----l---+--11----1--Thermal Resistance (R-Value): ______ _
Perimeter Insulation Depth (inches): _____ _
D §150(1): Water.absorption rate for the insulation material alone without facings is no greaterthan 0.3%; water vapor permeance
rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration.
3. EXTERIOR WALL
a. In~~ype ( e.x. Batt, Loose Fill, Spray Foam) a. Thermal Resistance (R-Value): _R_-__ \~~~---
b .. Insulation Type ( e.x. Batt, Loose Fill, Spray Foam)
-B-ran_d_:-::_-::_:,(r:~~<.N}.J.,"'-_""-_""-"'~"-'--'~'-~.:._.:._.:.._ ____ _
b. Thermal Resistance (R-Value): ______ _
Spray/Loose fill) Spray/Loose fill) Installed Actual Thickness
(inches):. _____ _ Contractor's min installed weight/ft' __ lb
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value)
D §150(c): lvfinimum R-13 insulation in wood-frame wall or equivalent U-factor .
. Exterior Foam Sheathing (rig· snlation)
Material: _______ .._..,_,__-1->-----Brand Name: _____________ _
Thickness (inches) : ____ ~------Thermal Resistance (R-Value) : ______ _
4. FOUNDATIONWALL ~
Material:
Thickness (inches): t) Brand Name: _____________ _
Thermal Resistance (R-Value): ______ _
5. CEILING () 1.-\.-0 ,0 ,
Batt or Blanket Type: ---=~=-"''""JL'--'------Brand Name: I..J::lA~ v'\ I~ ~
Loose Fill Type:___________ Thermal Resistance (R-Value): 7<.-:S,x..
Spray Foam Type:-------~~,._-Brand Name: ____________ _
\•1 II . Installed Actual Thickness (inches):_="~~-Contractor's min installed weight/ft' ___ lb
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value):
□ §150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor.
6. ATTIC ROOF INSULATION AND/,OR ATTIC RADIANT BARRIER
Material: '{' / _ t Brand Name: _____________ _
Material: . t f/ / Brand Name: Thickness (inches):~ / Thermal Resis_tan_c_e-(R--V-al-u-e)_: ______ _
□ §118(a): Insulation installed meets Standards for Insulating Material.
□ §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
2008 Residential Compliance Forms August 2009
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelope -Insulation; Roofing; Fenestration (Page 2 of3)
Site Address: I Enforcement Agency: ! Permit Number:
Descriotion of Roofine: Products
CRRC Product ID Manufacturer Product z:: /Roof Product Initial Solar Aged Solar Thermal
Number' Information Brand/Model T=e s1o~ Wei.e;ht1 Reflectance Reflectance4 Emittance
' V/ '\ □'
/ 1 □'
□'
1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at
ww.coolroofs.org/productslsearch.php
2. The weight in lbs per square feet of the roofing product being installed
3. Check box if the Aged Reflectance is a calculated value using the equation below,footnote 4.
4. If the aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the
directory and use the equation (0.2+0. l(Pinirial-0.2) to obtain a calculated a's!ed value.
✓ DCHECKAPPLICABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT,
□ The roof area covered by building integrated photovoltaic panels and building integrated solar thennal panels are exempt from the above Cool
Roof criteria.
□ Roof constructions that have thennal mass over the roof membrane with a weight of at least 2? lb/ft~ is exempted from the above Cool Roof
criteria.
To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of 20 mils across the entire roof surface and
meet minimum performance requirements listed in .fl 18(1)3 and Table 118-C. Select the annlicable coatinz
D Aluminum-Pio-mented Asohalt Roof Coating I D Cement-Based Roof Coating I D Other
✓ □ CRRC-1 Label Attached to CF-6R
· (Note ifno CRRC-1 label is available, this compliance method cannot be used and another method is reauired to meet comoliance).
FENESTRATION/GLAZING
Product # Total Quantity Add. Exterior Comments/
Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Dev. Location/ Special
Item !GROUP LIKE RODUCTSl factor1 SHGC1 Panes Certifie,l,1,2 (Ootional) ft' or Overhang Features
1 /I
2 \. I (\
3 / 17
/ ,
4
5
6
7.
8.
I. Use values from a fenestration product's NFRC Certified Label. For fenestration products without an NFRC label, use the default values from Section 116, Table
116-A and 116-B of the 2008 Energy Efficiency Standards.
2. NFRC Label Certtficates shall not be removed until the buildinJ? inspector has verified the efficiency. Enter Yes or No.
D § 116(a) 1: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
□ § 116(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on
the Certificate of Compliance (Form CF-JR).
D § 116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor; certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of §10-11 l(a)
D § 117: Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed.
2008 Residential Compliance Forms August2009
____ a ___ ,,,...
.
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelope -Insulation: Roofing; Fenestration (Page 3 of 3)
Site Address: I Enforcement Agency: I Permit Number:
DEC.LARATION STATEMENT
• I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct.
• I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative
of the person responsible for construction (responsible person).
• I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms
to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement
agency.
• I reviewed a copy of the Certificate of Compliance {CF-lR) form approved by the enforcement agency that identifies the specific
requirements for the installation. I certify that the requirements detailed on the CF-IR that apply to the installation have been met.
• I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building
permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a
signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building
owner at occupancy.
2008 Residential Compliance Forms August 2009