Loading...
HomeMy WebLinkAbout2339 PIO PICO DR; ; CB042616; Permit07-12-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Patio/Deck Permit Permit No CB042616 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 2339 PIO PICO DR CBAD PATIO 1563501200 Lot# $2,232 00 Construction Type TALLMAN RES-1 PATIO-72 SF & 72 SF DECK 0 NEW Applicant TALLMAN JEFFREY C&PAMELA 2339 PIO PICO DR CARLSBAD CA 92008 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# Owner TALLMAN JEFFREY C&PAMELA 2339 PIO PICO DR CARLSBAD CA 92008 ISSUED 07/01/2004 RMA 07/01/2004 07/01/2004 PC Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $4579 $000 $2976 $000 $1 00 $2290 $2290 $000 $000 $12235 Total Fees $122 35 Total Payments To Date $122 35 Balance Due $000 NOTICE Please take NOTICE that approval of your project includes the "Imposition of feas, dedications reservations or other exactions hereafter collectively referred to as "fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 07-07-2005 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Patio/Deck Permit Permit No CB042616 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # pphcant LLMAN JEFFREY C&P 2339 PIO PICO DR CBAD PATIO 1563501200 Lot# $2,232 00 Construction Type MAN RES-1 PATIO-72 SF & 72 SFNDECK 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* ELA 2339 I CARLSBAD CA 92008 Owner TALLMAN JEFFREY C&PAMELA 2339 PIO PICO DR CARLSBAD CA 92008 ISSUED 07/01/2004 RMA 07/01/2004 07/01/2004 PC Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $4579 $000 $2976 $000 $1 00 $2290 $000 $000 $000 $9945 Total Fees $99 45 Total Payments To Date $76 55 Balance Due $2290 0002 01 CGP 02 22-90 PERMIT HAS EXPIRED IN ACCORDANCE WITH C B.C. SECTION 106 4 4 AS AMENDED BY C M C 18 04 030 ntTF SIGNATURE Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 07-01-2004 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Patio/Deck Permit Permit No CB042616 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 2339 PIO PICO DR CBAD PATIO 1563501200 Lot# 0 $2,232 00 Construction Type NEW TALLMAN RES-2 PATIOS-144 SF EA Applicant TALLMAN JEFFREY C&PAMELA 2339 PIO PICO DR CARLSBAD CA 92008 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# Owner TALLMAN JEFFREY C&PAMELA 2339 PIO PICO DR CARLSBAD CA 92008 ISSUED 07/01/2004 RMA 07/01/2004 07/01/2004 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $4579 $000 $2976 $000 $1 00 $000 $000 $000 $000 $7655 Total Fees $76 55 Total Payments To Date $000 Balance Due $76 55 07/01/04 0002 01 02 76 .,55 BUILDING PLANS x IN STORAni- v ATTACHED PEPtf-7 HAS EXPIRED IN ACCORDANCE WITH UB.C SECTION 108.4.4 SIGNATURE. IK 6 fc « i/ o ftjiii r-r 1^i DATE • SIGNATURE LEARANCE PERMIT APPLICATION j CITY'OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 !l..t= PROJECT INFORMATION FOR OFFICE USE ON PLAN CHECK NjD EST VAL Plan Ck Deposit Validated By , Date ; (include I Business Name (ajLthis address) '^73r^ Lot No Subdivision Name/Number Unit No Phase No Aotal # of units Assessor's Parcel tt :xisting/Use Proposed Use Description of Work SQ FT #of Stories tt of Bedrooms tt of Bathrooms Name Address Contractor.:- • D Agent for Contractor•:•';(&.6wner City lent for Owner State/Zip Telephone Name Address City State/Zip Telephone i Name Address City State/Zip Telephone tt (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License tt Telephone tt Designer Name State License # Address City State/Zip Telephone 6,,, •,,WORKERS'COMPENSATION „ ,,. . Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage I* unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000), in addition to the cost of compensation damages as provided for In Section 3706 of the Labor code, interest and attorney s fees SIGNATURE DATE ^S^-fe^iW'W.• A-••••• -^i- :«-., -:-- - • -•, "-.'" -•*'••• :.--*' ' •• "'* •'"• -,' / I hereby affirm that I am exempt from the Contractor's License Law for the following reason / BET I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale / (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does / such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is / sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) / Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044. Business and Professions Code The I Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed I pursuant to the Contractor's License Law) I Q I am exempt under Section Business and Professions Code for this reason I 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement £] YES QNO x^TX ' ^*2 l/f,havai/ have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firmkto provide the proposed construction (include name / address / phone number / contractors license number) ^ ~ 4 I plan to provide portions of the work, but! have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) */7 /<^- 5 I will provide some of the work, butjjiave contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) NO PROPERTY OWNER SIGNATURE iCOMPLETE<THIS SECTION FOR Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? l~l YES l~l Is the faciiit/ *p be constructed withn 1,000 test of the outer boundary of a schoo) site? l~1 YES l~) NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THEREQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT iftsLi CONSTRUCTION LEND!NGLAQENC.Y j;..i:; i _u™ , '' i:I jj.'.:1"^. ~:*_ , , I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER'S NAME LENDER S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced fi^a period of 180 daysJSection 106 4 4 Uniform Building Code) / APPLICANT'S DATE YELLOW Applicant PINK Finance Inspection List Permit* CB042616 Type PATIO TALLMAN RES-1 PATIO-72 SF & 72 SF DECK Date Inspection Item Inspector Act Comments 02/01/200889 Final Combo PC Fl PHIL SAID THIS WAS PREVIOUSLY FINALED 09/06/200614 Frame/Steel/Bolting/Weldm PC AP DECK OK TO STUCCO 09/06/200619 Final Structural PC PA ENTRY LATTICE 09/06/2006 34 Rough Electric PC AP DECK RELOCATED LIGHTS 06/20/2005 92 Compliance Investigation PC NR Expire 06/20/2005 92 Compliance Investigation PC NR EXPIRE NO MORE WORK TO DATE 12/10/200411 Ftg/Foundation/Piers PC AP Monday February 04 2008 Page 1 of 1 ALLOWABLE RESIDENTIAL DECK JOIST SPANS1.2 ' 10% OF ' UP TO A | MAX OFi "pROMOTf FRONT PRi PROPERTY ^ SPACING 12" 16" 24" 12" 16" 24" 12" 16" 24" 12" 16: ^f*~' V 12" 16" 24" 12" 16" 24" DOUG FIR FLOOR JOISTS 6'3" 5'6" 5'0" 9'9" 8'9" 7'9" 12'9" 11 '9" 10'2" 16'5" IS'O" /13^> "• — -*=;- __ • 20'0" 18'0" 15'10" 22'9" 19'9" 16'0" REDWOOD FLOOR JOISTS 6'3" 5'6" 5'0" 9'9" 8'9" 7'9" 12'9" 11'9" ID'S" 16'5" 15'0B 13'0" 20'0" 18'0" 15'10" 22'6" 21'0" 17'0" es a live load of 40 psf and a dead load of 8 psf 'ana within 18* of grade, use pressure treated Douglas Fir-Larch or Foundation Grade Redwood > F(b)=825 psi. F9v)=90 psi. and E=1,200,000 psi forD F #2 i F(b)=925 psi. F9v)=80 psi. and E=1,200.000 psi for Redwood Allowable Beam Spans \12^incnes; 4 3 -4 3 ? 3 16 oo 28 30 34 36 . 18 2A 30 I 32 3B , i i 4 4x4 4x6 — 4x10 6x8 '4x10 6x10 4x10 6x10 6 4x6 4x8 4x10 6x8 4x14 6x12 4x14 6x12 8. . 4x6 4x8 4x12 6x10 4x14 6x12 4x14 6x12 Joist span (feet) 10 4x8 4x10 6x8 4x12 6x10 4x16 6x14 \ 4x16 6x14 ® 4x10 4x10 6x8 4x14 6x10_.. /fxT6^ fex14/ 4x16 6x14 T4 4x10 4x14 6x10 Txt4 6x12 4x18 6x14 4x18 6x14 16 4x14 _4x14 6x12 4x16 6x12 6x16 6x16 SETBACKS FOR R-1 PARCELS FRONT YARD - 20' from front property line INTERIOR SIDE YARD - 1 0% of 10' STREET SIDE YARD -10' REAR YARD - 20% of lot width "up tcTmaximum of 20 feet MAX LOT COVERAGE - 40% Contact the Planning Department for information on comer lots or lots with unusual configurations "and for information on Planned Communities, accessory structures, and building heights The telephone number for the Planning Department is 438-1161 / '10%, \ ." REAR Y EXISTING RES r V. DRAINAGE 2% MIN 20% of LOT ARO WIDTH TO A \ MAX OF 20' \ DENCE r 20 I s \, s / \ 10% OF LOT WIDTH UP TO A , MAX OF 10' LOT WIDTH MEASURED 20 ^FROM 20* BACK OF i FRONT PROPERTY UNE •' PROPERTY LINE_, i ""• STREET Minimum Square Footing Sizes (inches)1-2 Post. Spacing 4 6 i &12 4 12 14 16 18 20 6 14 16 20 22 24 8 16 20 22 24 28 Joist Span (feet) 10 18 22 24 28 32 f\2J/ 20 24 26 ^32 14 20 24 28 32 36 16 22 28 30 34 36 18 24 30 32 36 38 1 Assumes 1,000 psf soil bearing capacity 2 The minimum depth for all footings is 12 inches into natural grade C \Jobs\Tallman-job\(Rev2)x-site dwg, Site, 6/25/2004 10 09 48 AM N>CO CO CD TJ O TJ O""" O O £ ^^^™m T|"n^^ j^^ —y 73 CDCO Q. CD3 O CD O -* o ro8co PIO PICO DRIVE C \Jobs\Tallman-job\(rev4) 2nd fir dwg, New Entry (3), 6/25/2004 9 58 09 AM- $° 2.<7 ?a o o W S *is O 03 2." s5 2-03 ^_» 3" N So rff IT3 3- 5» g § 3Q.(I ai I OQ 33 (Dma•5 K to dTl (/I(Da I U) N (DQ. ^<n>(D 0^ 3" ff 3. O(D3.5U) -b. X*. O^j u>01 8S. 8# §5a; 15 m oo_ c 3 CO Q) Tl o m 0) °? C1 en 5? 21 Stucco ArchT> Z0) O 5 5T P c O COsa>. CD O o y, r->> O O3 W C/) w1 "O O"CD CDQ CL =ii co" U> U)2. R mCQ CD CO O3 m ICD 3 <JQ)S ^*.to r-k0) VJ " Mm O co r it ^ 1 r- TJ -~P H Oo > to > oj* dwpg O^SSa > 2m20, H ^S> CO 50 5sd oO 5ii ot-j O en a mTl TlTJm O BOTJ> m 5 oGO If