Loading...
HomeMy WebLinkAbout2350 CAMINO VIDA ROBLE; 101; CB152633; PermitCity of Carlsbad 02-09-2016 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB152633 Building lnspectio·n Request Line (760) 602-2725 Job Address: 2350 CAMINO VIDA ROBLE CBADSt: 101 Permit Type: Tl Sub T}ipe: INDUST Status: ISSUED Applied: 08/14/2015 Entered By: LSM Parcel No: 2130500900 Lot#: 0 Valuation: $23,500.00 Construction Type: NEW Occupancy Group: Reference# Project Title: CHUAO CHOCOLATIER-INSTALL PALLET STORAGE RACKING Applicant: WAREHOUSE SOLUTIONS INC P.O. BOX 60727 SAN DIEGO CA 92166 619-873-4410 Building Permit Add'l Building Permit Fee Plan Check Add'l Building Permit Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedidted Plan Review $238.77 $0.00 $167.14 $0.00 $0.00 $6.58 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $0.00 Total Fees: $413.49 Total Payments To Date: Inspector: fVl. ~$ Plan Approved: 09/17/2015 Issued: 09/17/2015 Inspect Area Plan Check #: Owner: DULCES REALTY LLC 2345 CAMINO VIDA ROBLE CARLSBAD CA 92011 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (31 04193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee Green Bldg Standards Plan Chk TOTAL PERMIT FEES $413.49 Balance Due: Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 ?? ?? $413.49 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been aiven a NOTICE similar to this or as ta which the statute of limitations has oreviouslv otherwise exoired. ' THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING 0BUILDING DFIRE DHEALTH DHAZMAT/APCD Cicyof Building Permit Application Plan Check No. C,& f ~~ 6__3 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value cQ 5 ~(1) Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov www.carlsbadca.gov Date 1f'/ ( 4-/ I s--lswPPP I JOB ADDRESS SUITE#/SPACE#/UNIT# rPN 221 2350 Camino Vida Roble N/A -881 -02 - CT/PROJECT # I LOT# I PHASE# I# OF UNITS I# BEDROOMS #BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I occ. GROUP Chuao Chocolatier V-B DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Installation of Pallet Storage Racking EXISTING USE I PROPOSED USE I GARAGE (SF) ~ PATIOS (SF) I DECKS (SF) FIREPLACE lAIR CONDITIONING I FIRE SPRINKLERS YES[]# NoD YEsONoD YEs[Z]NoD APPLICANT NAME Warehouse Solutions Inc. I~WN_TN'()E ~ • AI ~ .l'.£.t.\.:ier Primary Contact """· I So "'fit tl4.., , . ., I M ""- ADDRESS ADDRESS ~~ ?""..Jesi61 p 12562 Highway 67 235 • fida Roble #20 CITY STATE ZIP CITY ~STATE ~~ZIP Lakeside CA 92040 Carlsbad C 92011 PHONE I FAX PHONE ~0197 I FAX ~ (619) 873-44-10 (619) 449-1710 EMAIL EMAI/ johnfazio@warehousesolutions.com DESIGN PROFESSIONAL CONTRACTOR BUS. NAME Warehouse Solutions Inc. ADDRESS ADDRESS 12562 Highway 67 CITY STATE ZIP CITY STATE ZIP Lakeside CA 92040 PHONE I FAX PHONE I FAX (619) 873-4410 (619) 449-1710 EMAIL EMAIL johnfazio(ii2warehousesolutions.com I STATE LIC. # STATE LIC.# lccs1m24ICITYBUS LIC1226177 918115 (Sec. 7031.5 Busmess and Professtons Code: Any Ctty or County whtch reqUires a permtt to construct, alter, tmprove, demoltsh or repatr any structure, pnor to tts tssuance, also requtres the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. [Z] I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. State Compensation Insurance Fund Policy No. 9092900·2014 Expiration Date 3119116 This section need not be completed if the permit is for one hundred dollars ($1 00) or less. D Certificate of Exemption: I certify that in the performance of the for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to compensation is unlawful, and shall subject an employer to criminal penalties and civil fines up to on<l hundred thousand dollars (&100,000), in ' 3706 of the Labor code, interest and attorney's fees. . I . I ,__:.; DATE tl I '-f iS I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law}. I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes 0No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I tyrte of work): \ ~PROPERTY OWNER SIGNATURE 0AGENT DATE •c I certify that I have read the application and state that the above infonnation is conect and that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every penn it issued by the I Official under the provisions of this shall expire by limitation and become null and void if the building or work permit is not commenced within 180 days from the date of such permit or authoriz\~~r i s~pended or abandoned at any time after the work is commenced k$ APPLICANT'S \ \ \ DATE days (Section 106.4.4 Unifonn Building Code). STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE:. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCY tCommercial Projects o!!! ly I Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. I CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) ASSOCIATED CB# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION ~APPLICANT'S SIGNATURE DATE Inspection ist Permit#: CB152633 Type: Tl Date _Inspection ltE)m ____ _ 04/21/2016 19 Final Structural 04/21/2016 89 Final Combo 04/01/2016 89 Final Combo 03/14/2016 19 Final Structural Thursday, April 21, 2016 IN DUST Inspector Act MC Fl Rl MC NR MC CO CHUAO CHOCOLATIER-INSTALL PALLET STORAGE RACKING Comments RACKING SIGNAGE OK. COF NEED SIGNAGE POSTED. NEED FIRE AND POSTED SIGNAGE AT RACKING. Page 1 of 1 CITY 0~ CARLSBAD INSPECTION RECORD Building Division CB152633 2350 CAMINO VIDA ROBLE 101 CHUAO CHOCOLATIER-INSTALL PALLET STORAGE RACKING . ~~t#: IN~;~EHOUSE SOLUTJ'oNS INC Iii INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB Iii CALl BEfORE 3:30pm fOR NEXTWORK DAY INSPECTION 0 fOR BUILDING INSPECTION CAll: 760·602-2725 PY Required Prior to Requesting Building Finaf if Checked YES Planning/landscape Allow 48tfoUrs CM&l {Engineering ln$pedionsj Call before 2 pm Fire Prevention Allow 48 hours #19 FINAL #6:00 PRE·CONSTRUCTION MEETING REV 10/2012 SEE BACK FOR SPECIAL NOTES EsGil Corporation In Cl'artnersliip witli government for CBuiCtfing Safety DATE: 9/9/2015 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-2633 PROJECT ADDRESS: 2350 Camino Vida Roble SET: II PROJECT NAME: Storage Racks for Chuao Chocolatier 0 ~PLICANT YJURIS. 0 PLAN REVIEWER 0 FILE C2J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction''s codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C2J EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has be13n completed. Person contacted: Telephone#: Date contacted: (by: ) Email: Mail Telephone Fax In Person C2J REMARKS: 1. Fire Department approval is required. 2. Set II is i additional calculation provided. By: David Yao Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC log 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In CFartnersfiip witfi government for CBui{aing Safety DATE: 8/26/2015 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-2633 PROJECT ADDRESS: 2350 Camino Vida Roble SET: I PROJECT NAME: Storage Racks for Chuao Chocolatier D ~PLICANT _..,B'JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the! enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Warehouse Solutions, Inc. D EsGil Corporation staff did not advise the applicant that the plan check has been completed. [8J EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Warehouse Solutions, Inc. Telephone#: 619-873-4410 ,_9ate con;acted:8 (l,(o (by:YlA+-Email: johnfazio@warehousesolutions.com 't:}Mail vfelephone Fax In Person D REMARKS: By: David Yao Enclosures: EsGil Corporation D GA D EJ D MB D PC 8/18 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Ci,ty of Carlsbad 15-2633 8/26/2015 GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2350 Camino Vida Roble DATE PLAN RECEIVED BY ESGIL CORPORATION: 8/18 REVIEWED BY: David Yao FOREWORD (PLEASE READ): PLAN CHECK NO.: 15-2633 DATE REVIEW COMPLETED: 8/26/2015 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes 0 No CJ.ty of Carlsbad 15-2633 8/26/2015 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. The calculation provided is for type "B" only. Does the type A rack have heavier load for the column? Please check. 2. Provide calculation to show the 4" beam is adequate to support the 1000 lb load. 3. Fire Department approval is required. 4. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. C(ty of Carlsbad 15-2633 8/26/2015 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao PLAN CHECK NO.: 15-2633 DATE: 8/26/2015 BUILDING ADDRESS: 2350 Camino Vida Roble BUILDING OCCUPANCY: Sl BUILDING AREA Valuation PORTION (Sq. Ft.) Multiplier racks Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance ...,. ------------------------·---------------, _Pia_fl_~~-c~__f!~by Ordinance __ -~J Type of Review: Complete Review D Repetitive Fee =-~~Repeats Comments: D Other D Hourly EsGil Fee Reg. VALUE Mod. per city D Structural Only t-----tiHr @ • ($) 23,500 23,500 [, __ __;$_23_8_. 7__.71 [ ___ $_15_5_.2__.01 [ ___ $_13_3_.7.-~11 Sheet 1 of 1 macvalue.doc + PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 8/18/15 PROJECT NAME: INTERIOR RACKS PROJECT ID: Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.e:ov PLAN CHECK NO: CB152633 SET#: ADDRESS: 2350 CAMINO VIDA ROBLE APN: ~ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: JOHNFAZIO@WAREHOUSESOLUTIONS.COM For questions or clarifications on the attached checklist please contact the following reviiewer as marked: PLANNING 760-602-4610 D Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov D Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov D Remarks: ENGINEERING 760-602-2750 FIRE PI~EVENTION 760-602-4665 ~~ " ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL DATE: 09/17/15 PROJECT NAME:chuao racking PROJECT ID: PLAN CHECK NO: cb152633 SET#: II ADDRESS: 2345 cvr Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov 8 ,,P") ~ This plan check review is complete and has been APPROVED by th~~e Division. ~pe\ By: cwong A Final Inspection by the Division is required IZ! Yes D No D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: johnfazio@warehousesolutions.com &USPS You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviiewer as marked: D Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov D Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov D Remarks: 9/17/15 **APPROVED: D Kathleen Lawrence 760-602-27 41 Kathleen.Lawrence@carlsbadca.gov D Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov D D Greg: Ryan 760-602-4663 Gregory.Ryan@Ci'Jrlsbadca.gov ~ Cindy Wong 760-602-4662 Cynthia. Wong@carlsbadca.gov D Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSJ~S OF ISSUEANCE OF A BUILDING PERMIT. Page 1 of2 THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALI: APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. 8/24/15 ***The following is a partial approval only*** Information needs to be added to the racking plans (Owner set from Esgil). Please contact Cindy at 760-602-4662 to set an appointment. Appointments are available M-Th. Page 2 of2 Carlsbad Fire Department ---------· Plan Review Requirements Category: TI , INDUST Date of Report: 09-17-2015 Name: Address: Permit#: CB152633 WAREHOUSE SOLUTIONS INC P.O. BOX 60727 SANDIEGO CA 92166 Job Name: CHUAO CHOCOLATIER~ INSTALL Job Address: 2350 CAMINO VIDA ROBLE CBAD St: 101 Cond: CON0008519 [NOT MET] ***The following is a partial atJproval only*** Information needs to be added to the racking plans (Owner set from Esgil). Please contact Cindy at 760-602~4662 to set an appointment. Appoit1tments are available M-Th. Entry: 08/24/2015 By: cwong Action: P A Cond: CON0008557 [MET] **APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 09/17/2015 By: cwong Action: AP ~~· ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL DATE: 08/24/15 PROJECT NAME:chuao racking PROJECT ID: Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www .carlsbadca .gov PLAN CHECK NO: cb152633 SET#: I ADDRESS: 2345 cvr APN: D This plan check review is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required 1:8J Yes D No [8J This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: iohnfazio@warehousesolutions.com &USPS You may also have corrections from one or more of the divisions listE~d below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: D Chris Sexton D Kathleen Lawrence D Greg~ Ryan 760-602-4624 760-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Rycln@carlsbadca.gov D Gina Ruiz D Linda Ontiveros [ZJ Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D D D Dominic Fieri 760-6102-4664 Dominic.Fie~ri@ci;!rlsbadca.gov Remarks: 8/24/15 ***The following is a partial approval only*** Page 1 of2 Information needs to be added to the racking plans (Owner set from Esgil). Please contact Cindy at 760-602-4662 to set an appointment. Appointments are available M-Th. Page 2 of2 Carlsbad Fire Department Plan I:teview Nm-ne: Address: Pen-nit#: CB152633 Requirements Category.' Tl , INDUST WAREHOUSE SOLUTIONS INC P .0. BOX 60727 SAN DIEGQ CA 9216£5 Job Name: CHUAO CHOCOLATIERM INS"f ALL Job Address: 2350 CAMINO VIDA ROBLE CBAD INCOMPL'ETE'',, ,'fheJJemY,P1Lh~lYJUtubn1ittedfor,review_i~ incomplete. At this time, this office cannot adequately conduct a review to detennin~ COJ?pljance with the applicable codes and/or standards; Pleas.ereview carefully all comments att~c!J,e,d,.,"Plea:se''fesubmit the necessary plans and/or specifications, with changes "clouded", to this office fo~w"ru1d approvaL Cond: CON0008519 [NOT MET] ***The foliowing is a partial approval only*** Information needs to be added to the racking plans (Owner set ftom Esgil). Please contact Cindy at 760-602~4662 to set an appointment. Appointments are available M~ 'fh. Entry: 08124/2015 By: cwong Action: P A BY ....... .9.: ... 9H~.t!.1A..~ .... . DATE. SUBJECT. ......................... . "" ~ RAdK DE$IGN & ENGINEERING do. 412 WEST BROADWAY, $UITE #204 GLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 {:. A AA C t<. lA' ;1'H C')j;(1'v I -< t ~ k. + , I 7 .::: 3· 7ic.. l ~ SHEET NO ......................... . JOB NO. ~ ~~ ....... ~- 1 3·1 ;1.(, ,'r(/·Zl ...... ._....-.::::; J zo ,., er; .,,ol -:::; z, v ..... J"' '1 ''l<- L July 23, 2015 Robert G. Caputo, CFPS, CET 21992 E Camacho Rd • Queen Creek, AZ 85142 (760) 908-7753 • fax: (480) 207-6567 bcaputo@cox.net Mr. Greg Ryan, Deputy Fire Marshal Carlsbad Fire Department, Fire Prevention Bureau 1635 Faraday Avenue Carlsbad, CA 92008 RE: Chuao Chocolatier, 2350 Camino Vida Roble, Carlsbad, CA Fire Protection Technical Opinion & Report Dear Mr. Ryan: #3010 The following technical opinion and report is written "On behalf of Chuao Chocolatier at the direction of Michael Antonorsi. This report will address the pallet rack storage and distribution of Chuao's raw materials and finished goods. Chuao is currently conducting this same manufacturing, warehousing and distribution operation at their existing Carlsbad'location. Chuao Chocolatier produces a line of chocolates with unique flavor combinations such as chipotle caramel fudge truffles, dark chocolate bonbons filled with bacon flavors and other unique infusions. The processes include melting chocolate into bars and other candy shapes with flavored centers, then packaged for shipment. Report elements and compliance with the California Fire & Building Codes is based on information collected including an over-view of facility for the facility. Bob Caputo and/or Consolidated Consultants shall not be held liable for errors in this document due to failure to disclose information either intentional or otherwise. This document is for the sole purpose of construction and/or tenant occupancy approval only. Any discrepancies between the information in this report and conditions discovered during inspection are the sole responsibility of Chuao. Final inspection for occupancy and verification of compliance with requirements and conditions described in this report shall be the responsibility of the authority having jurisdiction and are outside the scope of this report. Negative Impact: This report shall confirm our opinion that Chuao Chocolatier's occupancy of the building under examination will be in complete compliance with the California Fire & Building Codes and will not create hazards beyond the occupancy use group indicated. This comprehensive fire protection plan is thorough, and will illustrate that an adequate level of fire and life safety protection is provided to the occupants of the building. Fire & Life Safety • Consutting • Planning • Analysis Qe;'\ 5 ;).Jg~ Chuao Chocolatier (Cont) Page 2 Report Purpose: 1. Identify materials being stored and distributed as well as the storage arrangement and prescribe methods of protection based on the California Fire Code. 2. Present information related to the design of the building/facility and business operations to indicate the acceptance of materials and safe practices for operations. Report Elements: • Provide an overview of the products and storage arrangements proposed for this site. • Classify all products stored, dispensed and distributed within the building. • Present an analysis of the design, operation and use of the building. • Outline and prescribe general safety procedures for occupant safety and building protection. Code Analysis/Technical References: The following codes and/or standards are applicable for this evaluation: • California Fire Code • California Building Code • California Mechanical Code • NFPA 13-Standard for the Installation of Sprinkler Systems (2013 edition) Overview: This facility is a free standing building approximately 27,000 ft2 in total, of which approJ<imately 7,000 ft2 will be designated as warehouse with single, double and multiple row (gravity flow) racks and storage up to 15 ft high. The building is protected with an approved fire sprinkler system designed to deliver a density/area of 0.45 gpm per ft2 over the most demanding 3000 ftl of floor area. The offices are protected with a design based upon light hazard occupancies. Building Construction, Occupancy Classification and Fire Protection: Building Type of Construction: Occupancy Classifications: Total Tenant Occupancy Area: Warehouse: Ceiling Height: Storage Height Ceiling Level Sprinkler Density: Commodity Classification VB fully sprinklered B/S-1 27,000 ft2 7,000 ft2 19ft (maximum) 15ft maximum 0.45 gpm/3000 ft2 Class Ill (Chocolate & paper products) Fire & Life Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier (Cont) Page 3 Commodity Classification Summary: Fire testing for storage of mixed commodities has shown that the fire takes on the characteristics of the higher commodity. For that reason, the requirements of NFPA 13 §5.6.1.2 were developed to provide guidance on choosing the appropriate commodity classification to govern sprinkler system design. As such, the fire sprinkler system protection requirements are required to be based on the highest classified commodity and storage arrangement and not the overall commodity mix in a fire area. Storage Arrangement: Table A.!'i.ti.:l Coutimt<•d Commodily -. \\'lw.-h. ,·anoned Chewing(;ulll J~arka~t·(l, t'OirtOIH~d Chncolat•· l'ackaf(<'d. Clrlotlt'd Cloth ( :anoJu-d and uot rartnned -N~uural fiher, \'iscose ~ S~mheti•·d ( :oroa Produt'ls l~ackagl'tl. ~·;.tntmed Cofli·" -Cauned. t'ari«Htcd -Packaged~ canouetl Commodity Cla'i'i Cttss Ill f'hlSS 1!1 Cia" I\' (:!;'""'- !. ltss I Class Ill The tenant will be storing all products in 15 ft high standard pallet racks arranged in single and double row configurations without solid shelves. 10ft aisles will be provided between the raclk rows. NFPA 13, 2013 edition, Chapter 16 provides sprinkler protection criteria for storage of Class I-IV commodities stored over 12ft and up to 15ft on pallet racks. For un-encapsulated class Ill commodities, Table 16.2.1.3.2 provides criteria for the protection of Class 1-IV commodities in the top section of the table and directs us to figure 16.2.1.3.2 (C). Table 16.2.1.3.2 Single-or Double-Row Racks-Storage Height Over 12ft (3.7 m) Up to and Including 25ft (7.() m) (:("iJiug Sprinkler \\'1uer Demand Alslt"s* With lu~Rat'k Sprinklerr. Wi4hout Jn-R~"·k Sprinklt.·~ Sprinkler!; Commodity .\Jandato''Y A1)1)ly Figur(" Apply Figun· H.:~ight eitl""S Encapc;1datNl ft ... Jn.Rat.·k Figun.,_ CUr\'t', .. 16.2.l.:i.4.l Figure Cm·n~s W.2.I.:l.4.1 L2 C:;uuln Fand II No No IG.2.1.~.2(a) l6.2.l.:l.~(a) Yes 8 ~.·1 Aaud ll Eaud(; 1.2 Caud n G~tnrl II Yes ~0 16.2.L:t2(t~) lt).2.i.:t2(e) y, . ., 2A A and B E:mtiF 1.2 t:andD G<tlldfl No ~0 J6.2.1.:1.2{h) lti.2.1.~t2~h' Yt·s s 2A ,\amlll EomdF II Owr 12ft 1.2 CamlB G;uJdJI (~t7m) Yes No Hi2. I ,$.2(d 16.2.1.:1.2(f') Vt:s UJ~ 10 omd R 2.-1 .:\~md n -EamlF i1u.:lmling Q Q \'t''i ( """I IG 2tlfl G __...._ 1.2 Cand f) c~uulll O).lm) J 10.2.1.!\.~~f') lli.2.13.2~1 8 2.·1 A and U EmuiF -:-1.2 Cand [) -Y<~S I lt·vd 16.2.1$.2(() 8 ~.4 AamiU J.2 Cand l.l (~and H No !'-;o 16,2.L:l.2(d) lil.2.t.3.2t(1.J Y('S 2A ,\and H F. and F 1\' 1.2 C;uuJl) Yes lk\•f•l JG.2.1.3.~(g) 8 ~A A~mll B - Fire & Life Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier (Cont) Page 4 i Ceiling sprinkler density (mm/min) c 6.1 g 4000 e! Q) g-w 3000 32 c ·.:: 0. C/) 2000 0 <1l e ~ 1000 8.2 10.2 12.2 14.3 16.3 18.3 I I I I I I A -8 0 1-E F H I c G J -~ 0.15 0.20 0.25 0.30 0.35 0.40 0.45 Q) 0 Ceiling sprinkler density (gpm/tt2) 20.4 i § 372 :;::: @ Q) g- 279 w 32 c ·.:: c. 186 (/) Single po int nly 0 <1l design o 93 0.50 e <1l c Ol ·u; Q) 0 Curve legend E-Single-or double-row racks wilh 8 fl (2.44 m) aisles and high-temperature ceiling sprinklers F-Single· or double-row rad<S with BIt {2.44 m) aisles and ordinary-temperature ceiJil;g sprinklers FIGURE 16.2.1.3.2(c) Sprinkler System Design Curves-20ft (6.1 m) High Rack Storage- Class III N onencapsulated Commodities-Conventional Pallets. The base density for 20ft high storage is 0.37 gpm over 2,000 ft2 of floor area which is well below the existing sprinkler system design 0.45 gpm/3,000 ft2• An additional margin of safety exists because figure 16.2.1.3.4.1 allows the initial prescribed density to be adjusted to 60% dues to the 15ft height of proposed storage. 3_66 Height of storage (m) . 175 3.05 4.57 6.10 7.62 9.14 10.67 150 l~rHHH-K++++++·~~~ Height of storage (ft) FIGUIU: Ht2.1.3.4.1 Ceiling Sprinkler Density vs. Storage Height. Reduction calculation: 0.37 gpm x .60 = 0.22 gpm/2,000 ftl Fire & Life Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier (Cont) Page 5 As such, the existing fire sprinkler system is more than twice the required density with a remote area calculated at 1/3rd larger than required for the proposed single and double row pallet rack storage of raw materials, which include 25 lb bags of chocolate, sugar and food grade flavorings. The racks shall not have solid shelving as defined by NFPA 13 based on the method used to calculate the rack shelf area. The term rack shelf area is defined in §3.9.3. 7.6 as "the area of the horizontal surface of a shelf in a rack defined by perimeter aisle(s) or nominal 6" flue spaces on alii four sides or by the placement of loads that block openings that would otherwise serve as the requi1red flue spaces." The placement of loads on the rack affects the calculated area of the shelf. Previous editions of the standard only dealt with the shelf material alone and did not consider the loads on the shelf. With this new definition, shelving material that had been classified as open, such as wire grate more than 50 percent open, could be calculated as solid shelf if the loads on the shelf cover the required flue spaces to separate shelf area calculations. The intent of §16.1.6 is to have flues surrounding the load or shelf material that will not block more I than 20 ft2 in area. While the shelf material (if any) is considered open, the distribution is blocked if the area of load or shelf is greater than 20 ft2 in area and solid shelf rack rules would apply per §16.1.6.1 as follows: Where solid shelving in single-, double-, and multiple-row racks exceeds 20 ft2 but does not exceed 64 ft2) in area, sprinklers shall not be required below every shelf, but shall be installed at the ceiling and below shelves at intermediate levels not more than 6ft apart vertically. The tenant is required to maintain 6" transverse flue spaces at the rack uprights and between the unit loads at or near the center of load beams. Random variations are permitted. If solid wood shelves are utilized, the tenant is required to cut the shelves to create 6" flues at the rack u'prights and at the midpoint between the pallet rack uprights (3" min per side). Gravity Flow Rack Sections: For the purpose of protection criteria, gravity flow racks are considered multiple row racks as defined in section 3.9.3. 7.3 which notes that racks greater than 12ft in depth or single-or double-row racks separated by aisles less than 3.5 ft wide having an overall width greater than 12 ft. Protection criteria is provided in Table 16.2.1.3.3.1 below: - Fire & Life Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier {Cont) Page 6 Table Hi.2.UUU Multiple-Row Racks-Rat·k Depth Up to and Iududing Hi ft (4.!1 m). Aisles R ft (2.4 m) or Wider and Storage Height Over 12ft (3.7 m) Up to 25ft (7.6 m) CeilingSp•inkh,rWmer Hen_m_n_d __________ _ \\'ilh In-Rack Sp•·inkiers Sprinklers At>!' I)' Ent.'UJl• l\laodatm:· Fi~ure 1.25 sulated In-Rack Fit<lll'C <.:m'\'tl'~ l!i.2.1.!1.4.1 ;.tf}ento~ity Cnmmoditv ll<·iglu Cia" · No tn.~.t.:~.2(a) r\n r-------- '\~·~ lti:!.t.:\.2(a) Yt·~ Nn ;\!n lii.~.L\1.2(h) i\'o 1li! IH.2.t,;3.2(h) Caml Y<.·s -I) (No) (No) w.:u.~.~(d y.,, Xo ( --¥ ~ lf\.'!.1.:{.2({') Y.-~s 01'!'1'1211 Il Cl.7m) np to and 1------+-~'"""'i',.--1---,"""'.,..._-+-----l indnding G 15 n (-!.6 111 m) ---- 'No No lli.2.1.:1.2(d) ~0 Ceiling sprinkler density (mm/min) c: 6.1 8.2 10.2 12.2 14.3 16.3 18.3 20.4 0 4000 ~ I g. A -.B -D E F H J 05 3000 32 .§ 0.. (/) 2000 0 {lj ~ {lj c: 1000 -~ 0.15 ~ 0.20 I c G 0.25 0.30 0.35 0.40 0.45 Ceiling sprinkler density (gpmttt2) 186 Single po int nly design o 93 0.50 \\'hhuut Jn~Uack Sprinklers f'i!(UI'e tft.:!.l.:t2(a} 16.2.L:1.:.!(a) 16.:!.1.:1.2\h) Hi.~.!.:1.2(hl lli.2.1.:l2k)' 16.2.D.2(d) At>Pi)' Figm·<· 1.21\ {:m·n•s lli.2.liiA.I )1. Ht~1~sity ·r----~ Iandi Nrt ---\'t'" --~--·-·- I aml.J Yc."> land.! Yl'S No !,..iwol.l ......... \(•s I andJ { Y<•s} "'" ~ "it\ NA Camlfl Nn .i\n 1-Multiple:row racks with 8ft (2 .. 44 m) or wider aisles and high- tempe-rature ceiling sprinklers J-Multiple-row racks with 6 ft (2 .. 44 m} or wider aisles and ordinary· tempe,rature ceiling sprinklers FIGURE !6.2.1.3.2(c) Sprinkler System Des;gn Cmves-20ft (6.1 m) High Rack Stm·age I Class III Nonencapsulated Commodities -Conventional Pallets. The initial prescribed density/area based on the single point design criteria shown as Curve I is 0.47 gpm over the most demanding 2,000 ft2 of floor area. However, the density is permitted to be reduced by 40% based on Figure 16.2.1.3.4.1 (below) Fire & Ufe Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier (Cant) Page 7 10 12 15 20 25 30 35 Heigh! of storage (ft) FIGURE W.2.l.:l.4.1 Cl'iling Sprinkl<•r D<•nsity \'s. Srontg" Hdght. Reduction calculation: 0.47 gpm x .60 = 0.28 gpm/2,000 ft2 As noted for other rack storage arrangements, the existing fire sprinkler system is adequate or exceeds the prescribed design criteria for this and all storage arrangements. Hazardous Materials: Chuao Chocolatiers does not use or store any hazardous materials (with exception of normal household cleaning products) as stated in the attached letter stating such. Industrial Fork Trucks: Chuao will have an electric powered industrial forklifnor use in moving materials throughout the facility. Electrical charging of battery powered units is performed with approved charging units which will be located near the pallet racks. Storage of combustible materials is prohibited within 3ft of a charging unit per CFC §309.2. A minimum 4-A:20-B:C extinguisher will be located within 20ft of the battery chargers. Adequate ventilation will be provided during charging operations by opening overhead doors to permit fresh air at all times. Access/Egress Doors: Existing access doors are provided every 100 lineal feet along the exterior walls. Doors are 3 feet in width and 6 feet 8 inches in height. Only approved locking devices may be used and doors are accessible at grade level. The basic layout of the building is in conformance with the CBC. The travel distance from any point in the building to an exit does not exceed 250 feet. All exit doors are at least three feet wide and proper exit signs over each door are provided. - Fire & Life Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier (Cont) Page 8 Fire Extinguishers: Minimum 4-A:20-B:C rated fire extinguishers shall be provided for every 75 feet of travel distance throughout the warehouse area, including those required to be located within 20ft of inductrial fork truck charging stations as noted above, as required by CFC §309.4. Extinguishers will be with the top of the extinguisher not more than 5 ft above the floor. General Safety Practices: ¥" No smoking will be permitted in the building. ¥" All employees will receive special training on the use of portable fire extinguishers of the type to be provided in this building. An evacuation plan will be in place. ¥" Exit doors will be maintained unobstructed and will be opened weekly to ensure their operation. ¥" The Fire Department shall be notified of any fires within this facility, regardless of size and fire department involvement. ¥" Egress aisles shall remain clear at all times (except for loads being moved in or out). ¥" Exit signs shall be illuminated when building is occupied ¥" Fire extinguishers shall be serviced annually by a company licensed by the State Fire Marshal and whenever extinguishers have been discharged or tampered with. ¥" No electrical cords extending through walls, ceilings, floors, under doors, or floor covering are permitted. Damaged electrical cords, plugs, or outlets shall be promptly replaced. ¥" Dumpsters shall be kept a minimum of 5 feet from combustibles with covers kept closed. ¥" Employees will be trained to maintain the storage height limitations (18" below sprinklr deflectors minimum) ¥" Storage of combustibles shall be maintained a minimum of 3ft away from the industrial forklift charging unit. Smoke & Heat Vents: As noted in CFC Table 3206.2, draft curtains and smoke/heat vents are not required for storage areas less than 12,000 ft2 under option #1 in non-public accessible buildings Hydrants/Access Roadways: Hydrants and fire department access roadways will continue to be maintained unobstructed and accessible to emergency response crews. Management of Change: The tenant shall be required to review the conditions and requirements of this report if changes are made in the storage arrangement (such as relocating racks to create narrower aisles). Fire & Life Safety • Consulting • Planning • Analysis • Inspections Chuao Chocolatier (Cont} Page 9 Conclusion: Based upon our review of the proposed storage arrangements and use, and the recommendations contained in this report, it is our opinion that Chuao Chocolatier will be in full compliance with the requirements of the CBC, CFC, CMC, NFPA standards and Carlsbad Fire Prevention Bureau requirements. If you have any comments or questions regarding this report or the proposed use of this facility, please do not hesitate to contact the undersigned or the owner directly. Respectfully submitted, #3010 Robert G. Caputo, CFPS, CET President Fire & Life Safety • Consulting • Planning • Analysis • Inspections ' . sY: ........ 9.: ... 9.t!A.~!.~.~ .... . DATE .. ~.::-:~::-:.J.~ ............ . SUBJECT. ......................... . RAdK DE~IGN & ENGINEERING do. 412 WE~T BROADWAY, ~UITE #204 dLENDALE, dA. 91204 TEL:{818)240-3810 FAX:{818)240-3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: CHUAO CHOCOLATIER 2350 CAMINO VIDA ROBLE, #201-301 CARLSBAD, CA 9201 1 PER CBC 2013 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3 RMI/ANSI/MH 16.1:2008 STORAGE RACKS CAPACITY: 3500 #/ LEVEL 1000 #/ LEVEL AT TYPE "A" CARTON FLOW SHELF LEVELS CALCS. 1 THRU 4 DRAWINGS: RD-18070 SHEET NO ......... J .............. .. JOB NO .... ~.P..:-:-:.~.~g.?..Q .. . BY : ...... :~.: ... .Q.~.A~!A.~ .... . DATE .. ~.~.?.:-::.!.:?. ............ . SUBJECT. ......................... . r ,--- 0 I'- ~ '"" ,--- 0 I'- ......-' ,' · .. ,· BEAM DESIGN r[l, [Q [z 3/4"[ 144" 3500 #I LEVEL 3500 #I LEVEL TYPE "8" IX =3.22 sx =1.23 Fy =55KSI. SEISMIC DESIGN r RAdK DE~IdN & ENGINEERING do. 412 WE~T BROADWAY, ~UITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 F.AX:(818)240-3813 1111 SIDE VIEW LOAD PER BEAM + 25% IMPACT LOAD (3.5 Kx.88)+( 1 .8 Kx.25) = 3.5 = 1.8 K 2 BEAMS M= wl2 =32 "K 8 SR=.96<1.23 6.= 5xwl4 =.72"<_L_ =.80" 384.1x.E 180 V=~xW Rx1.4 CBC 2013 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3, RMI/ANSI/MH 16.1:2008 S os =0.76 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. RMI 2.6 AND 2.6.3 R=4 BRACED 2 W=D.L.+ "3 PALLET LOAD TYPE "B" GOVERNS LOAD PER COL. = 2x3.5 K =3.5 K 2 COL. P= .2 DL+ (3.5 KxO. 75)=2.8 K W=.20L+ (3.5;Lx0.67)= 2.5 K V = .23 K LONGIT. V = .35 K TRANS. LONGIT. SEISMIC 0 1'- r-------t--.15K f------+-.oaK SHEET NO ......... ~ .............. . JOB NO .... ~.P..::-:.1.~.9.?.S~ .. . s.z"K ?.s·K 7.8 "K ,BY ..... ~ .. 9.: ... 9..~!.\.~_1!.\.tL .. DATE .. ~.::-:?.::-:.!.~ ............ . SUBJECT. ......................... . COLUMN DESIGN t ' r~ J:-~ [~ COMBINED STRESS RATIO 2 Pex=~=20 0 ( KL) 2 . RAdK DESIGN & ENdiNEERING do. 412 WEST BROADWAY, ~UITE #204 GLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 Fy=55KSI Ae=.62 lx=.95 Se=.6 rx =1.2 r y= 1.1 KL _ 70x1.7 _96 rx -1.2 - KL_ 42 _38 ry -u- Mn =Se .Fy = 35 Oc.P + Ob.Cmx.M = 74<1 Pn Mn.OX · Pn= Fn .Ae = 16.0 K ax=1-OcP = .74 Pex Cmx=.85 BASE PLATE SHEET NO ......... ~ .............. . JOB NO .... ~.P..::-:.!.~g.?..9 .. . ANCH. TENSION = 0 ANCHOR SHEAR= .12 K 8"x5"x3/8" BASE PLATE (2)-1/2"¢ ANCHORS PER BASE PL., 3 1/4" EMB. HILT! KWIK BOLT-TZ ESR-1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.07x 1 x65=2.3 K 7 /16"¢ RIVET A = . 1 Fy = 79 KSI Pa = .1 x79x.4 = 3 K BEARING CAPACITY OF COL. HOLE Ma = (2.3 Kx4")+(1.1 Kxz") = 11.4 "K 3 PIN CONN. CONN. M -.01 xwi 2-2.5 "K END-- M=6.s"K M=9.o"K SEISMIC TOTAL s.z·· ~ 6.s·· 6.5'K ____ ) sv -----~-.9.: ... 9..1:i.~-~-'A-~----­ DATE . -~-~~-::-:.! .. ~------------. RAdK DE~IGN & ENdiNEERINd do. 412 WEST BROADWAY, ~UITE #204 SHEET NO ....... A .............. . SUBJECT. ......................... . OVERTURNING NO UPLIFT LOAD TO DIAGONAL p -.35 KX2 X ..22_-.87 K -COL 42 - Fy=55KSI Ae=.26 rx =.48 L= 52" P0 = 3.1 K CHECK WELDS Pn= (1-.Ot1L)L.t.Fu = 4.4K 0= 2.55 fn_=1.7Kx2 =3_4K 0 SIDES CHECK SLAB 2800 -s 6 o' 500 - - vi806=28" 5.6x 144=806 o" M= (-8-)2x500x j_ x12= 1333 "# 12 2 S= 12x62 = 72 6 1ii3 = 19 < 1.6 -J2500 =80 GLENDALE, dA. 91204 JOB NO.---~.P..::-:.~-~_q_?._q __ - TEL:(818)240-3810 FAX:(818)240-3813 2.8 K 2.8K 1---------'I<Q f--------'1< 'N g """-~o==1---+--+~ 42" TOP LEVEL LOADING W= 0.20L+ 1.8LL=2.0 K LOAD PER COL. V= .27 K 11/" -M ~tA-x t=.06" .. ~d ... 4. . . . M0r = .27 Kxz x140" = 74"K COL MR = 2.0 Kx42" = 82 "K NO UPLIFT ' Dl }D I I D I .---~~ I L...-.-----t--' D I ' D I 1./ D I 2800# t • . . . 28" 14" 6" CONCRETE SLAB 2500 PSI. CONC. 500 PSI~. SOIL