HomeMy WebLinkAbout2352 Caringa Way; C; CBR2017~0210; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Print Date: 03/02/2017 Residential Permit Permit No: CBR2017-0210
www.carlsbadca.gov
Job Address:2352 Caringa Way,C
Permit Type:BLDG-Residential Work Class:P/M/E Status:Closed -Finaled
Parcel No:2152402928 Lot #:Applied:02/01/2017
Valuation:$0.00 Reference #:Issued:02/01/2017
Occupancy Group:Construction Type:Finaled:
# Dwelling Units:Bathrooms:Inspector:
Bedrooms:Orig. Plan Check #:
Plan Check #:
Project Title:
Description:DUNNE: REPLACE FAU & A/C UNIT
Owner:Contractor:
JACLYN L DUNNE ATLAS HVAC INC
2352 Caringa Way,C
CARLSBAD, CA 92009 8525 Arjons Dr,U
San Diego, CA 92126-4384
877-452-8527
PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT $166.00
Total Fees:$166.00 Total Payments To Date:$166.00 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction."You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project.NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:0 PLANNING 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH 0 HAZMATIAPCD ,
CC •.
•ity 01'Building Permit Application Plan Check No.ll -COI
1635 Faraday Ave., Carlsbad, CA 92008
CLIC
Est. Value tO 0
Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. DepositCarlsbademail: building@carlsbadca.gov ,
www.carlsbadca.gov Date 94 1 /-
.
c
-.WPPP
JOB ADDRESS ,,,,SUITEVSPACEVUNIT#APN
,-,5Z..-(ex(t
y...r
())0.;(1.-C.-e....----
CT/PROJECT#LOT#-PHASE #OF UNITS # BEDROOMS #BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK:include Square Feet of Affected Area(s)
Q e.)lace_FAv d-/VC
EXISANG USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
V 6S'atis4N.Gt-YES.NOD i YES ONO0 YESEiNOD
APPLICANT NAME PROPERTY OWNER
Primary Contact Pe a--
..:1--62 V Asev..r jc't C-11 V\0 ti III1 -f_
ADDRESS ....ADDRESS ,.,1 ..... ....•
6 .??0 11 c5Ae.i'L c../-1.(4p-I (0‘t-c.-Coq-
1 r.c.,c...win U..-;* C
CITY,..„..—.STATE ZIP CITY
(,..Lc vix\ep
--
STAleA
`-'1
cIZIP 200c1---Jg.v...e.CA—4. 2a'1 (
PCNE
FAX PHON FAX
6 1.0:_.)
5 3---(2k.p c 6.0)its --o9 1
E IL E IL
DESIGN PROFESSIONA-CONTRACTOR BUS. NAMEA+_I as 14i/t-C-
ADDRESS ADDRESS_
YS ZS
--Ar Sov.s Or 5i6----u
CITY STATE ZIP
CITY4..
STATE ZIP
2. i Lr‘
PHONE FAX P1 .
ITF 77S(1-S2---5 -t7 FAX
EMAIL EMAI
STATE LIC.#STATE LIC.#CLASS CITY BUS.
cl—Sic1,2 7 CI.o l
-
LICL169 11
(Sec.7031.5 Business and Professions Code: Any City or County which requiresa permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)).
WORKERS'COMPENSATION
1 Workers' Compensation Declaration: I hereby affirm under penaltyofperjury one ofthe following declarations:
Ihave and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
Ihave and will maintain workers' compensation,as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number am: Insurance Co.Policy No.Expiration Date
his ection need not be completed if the permitis for one hundred dollars ($100) or less.i*Certificate of Exemption:I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
alifornia.WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the costofcompensation, damages as provided for in Section 3706 ofthe Labor code, interest and attorney's fees.
.ES CONTRACTOR SIGNATURE _......-----------'"../."--___.__......--41?!iGENT DATE 7
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
I,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
ID1,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law).
E]I am exempt under Section Business and Professions Code for this reason:
1.I personally plan to provide the major labor and materials for construction of the proposed property improvement.DYes DNo
2.I (have / have not) signed an application for a building permit for the proposed work.
3.I have contracted with the following person (firm) to provide the proposed construction (include name address Iphone/contractors' license number):
4.1 plan to provide portionsofthe work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
5.I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone/type of work):
......---.-...--nAGENT DATE
COMPLETE THIS SECTION FOR NON -RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act?0Yes El No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?0 Yes El No
Isthe facility to be constructed within 1,000 feet of the outer boundary of a school site?El Yes CI No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lenders Name Lender's Address
APPLICANT CERTIFICATION
Icertify thatI have read the application and state that the above Information Isconedand that the information on the plans is accurate.Iagree to comply with all City ordinances and State laws relating to building constniction.
Ihereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes.I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become nut and void it the building or work authorized by such permit is not commenced within
180 days from the dateofsuch permit or ifthe buiding or wort authorized by suchpentis suspended or abandoned at any time after the work is commenced fora period of 180 days (Section 106.4.4 Uniform Building Code).
At5APPLICANT'S SIGNATUR DATE 17
STOP
STOP:THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email buildingacarlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#:(Office Use Only)
C•ONTACT NAME OCCUPANT NAME
A•DDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS0PICK UP: CONTACT (Listed above) OCCUPANT (Listedabove)
CONTRACTOR (On Pg. 1)
ASSOCIATED CB#
0 MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On P.1) NOCHANGEINUSE/NOCONSTRUCTION
CI MAIL/FAXTOOTHER: CHANGE OF USE/NO CONSTRUCTION
•
AKAPPLICANT'S SIGNATURE DATE
-..............-.-WPM MI
PERIVTANSPECTION HISTORY REPORT (CBR2017-0210)
Permit Type:BLDG-Residential Application Date:02/01/2017 Owner:JACLYN DUNNE
Work Class:P/M/E Issue Date:02/01/2017 Subdivision:
Status:Closed -Finaled Expiration Date:08/29/2017 Address:2352 Caringa Way, C
Carlsbad, CA 92009-6358
IVR Number:1724
Scheduled Actual
Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
03/02/2017 03/02/2017 BLDG-43 Air 014390-2017 Passed Jonathan West Complete
Cond./Furnace Set
BLDG-Final 014391 -2017 Passed Jonathan West Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Mechanical Final Yes
March 02, 2017 Page 1 of 1
1
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 1 of 7 )
Project Name:Jaclyn Enforcement Agency:City of Carlsbad Permit Number:CBR2017-0210
Dwelling Address:2352 Caringa Way. Unit #C [Jaclyn]City:Carlsbad Zip Code:92009
A. General Information
01 Dwelling Unit Name Jaclyn 02 Climate Zone 7
Dwelling Unit Total Conditioned Floor Number of Space Conditioning03108004 1Area (ft2)Systems in this Dwelling Unit.
05 Certificate of Compliance Type Prescriptive alterations (CF1R-ALT )06 Method used to Calculate HVAC Loads NotApplicableEquipmentChangeout
Calculated Dwelling Unit Sensible Calculated Dwelling Unit Heating Load0745000.08 36000Cooling Load (Btuh)(Btuh)
09 Dwelling Unit Number of Bedrooms 2
MCH-01b Space Conditioning Systems Ducts and Fans -Prescriptive Alterations
B. Space Conditioning (SC) System Information
01 02 03 04 05 06 07 08 09 10
SC System SC System CFA served Is the SC Installing aInstalling new SC Installing more Installing InstallingrefrigerantaIdentification or Location or Area by this SC systemsystem than 40 feet of entirely new entirely new SC Alteration Type
Name Served System (ft2)ducted containing components?ducts?duct system?system?system?component?
Altered space
Jaclyn House 1080 Yes Yes Yes No No No conditioning
system
Registration Number: 417-A0013621A-M0100001A-0000 Registration Date/Time: 2017-02-09 10:41:15 HERS Provider:CHEERS
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-02-09 10:41:17
Schema Version: 2013.1.008
I
I
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 2 of 7 )I
C.Space Conditioning (SC)System Alterations Compliance Information
01 02 03 04 05 06 07 08 09 10 11 12 13
Central Fan
Integrated
Heating Cooling New or (CFI)
System Altered Heating Minimum Altered Cooling Minimum Required Replaced New Ventilation
Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Duct Duct System
or Name System Type Component Type Value System Type Components Type Value Type Length R-Value Status
All new All newCentral gas heating Central Not a CFIJaclynAFUE0.78 cooling SEER 15 Setback LTE4OFt R6furnacecomponensplitAC'system
is components
.,•.,
D.Installed Heating Equipment Information
01 02 03 04 05 06 07
System Identification or Heating Efficiency Heating Unit Heating Unit Heating Unit serial Rated Heating Capacity,
Name Heating Efficiency Type Value Manufacturer Model Number number Output (BTUH)
Jaclyn AFUE 80.0 Bryant 310JAV024045AG 4816A15398 45000
Notes:
E.Installed Cooling Equipment information
01 I 02 I 03 04 I 05 I 06 07 I 08
Condenser or Package Unit
Condenser or Condenser or Condenser or System Rated Cooling Condenser Rated
System Identification Cooling Efficiency Cooling Efficiency Package Unit Package Unit Package Unit Capacity at Design Nominal Capacity
or Name Type Value Manufacturer Model Number Serial Number Conditions (BTUH)(ton)
Jaclyn SEER 15.0 Bryant 105ANA0360 .36000 3.00
Registration Number: 417-A0013621A-M0100001A-0000 Registration Date/Time: 2017-02-09 10:41:15 HERS Provider:CHEERS
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-02-09 10:41:17
Schema Version: 2013.1.008
I
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 )
E.Installed Cooling Equipment information
01 02 I 03 04 05 I 06 07 I 08
Condenser or Package Unit
Condenser or Condenser or Condenser or System Rated Cooling Condenser Rated
System Identification Cooling Efficiency Cooling Efficiency Package Unit Package Unit Package Unit Capacity at Design Nominal Capacity
or Name Type Value Manufacturer Model Number Serial Number Conditions (BTUH)(ton)
Notes:
F.Extension of Existing Duct System, Greater Than 40 Feet
This section does not apply to this project.
G.Installed Duct System information
This section does not apply to this project.
H. Installed Air Filter Device Information
This section does not apply to this project.
I.Air Filter Device Requirements
This section does not apply to this project.
Registration Number: 417-A0013621A-M0100001A-0000 Registration Date/Time: 2017-02-09 10:41:15 HERS Provider:CHEERS
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-02-09 10:41:17
Schema Version: 2013.1.008
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 4 of 7 )
J. HERS Verification Requirements
01 02 03 04 05 06 07 08 09 10
MCH2O MCH21 MCH22 MCH23 MCH25 MCH28
Exemption
from
Minimum
Exemption R-Value for AHU
System SC System From Duct Duct Ducts In Ducts Located AHU Fan Airflow
Identification or Location or Area Leakage Leakage Conditioned In Cond Space Efficacy Rate Refrigerant Return Duct Design
Name Served Requirements Test Space Verification (W/cfm)(dm/ton)Charge Table 150.0-C or D
No ''NoJaclynHouseYes No No No No NoexemptionsExemption
Notes:
—.
Registration Number: 417-A0013621A-M0100001A-0000 Registration Date/Time: 2017-02-09 10:41:15 HERS Provider:CHEERS
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-02-09 10:41:17
Schema Version: 2013.1.008
I
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of 7 )
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b).
03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing.See sections
150.0(h)1 and 2).
04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum
inlet-to-outlet temperature rise specification.See Section 150.0(h)4.
05 Standby Losses and Pilot Lights:Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d).
Cooling Equipment
06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section
150.0(j)2 and 3, and Section 150.0(m)9.
08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet.See Section 150.0(h)3A.
09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing.See Section
150.0(h)1 and 2.
Air Distribution System Ducts, Plenums and Fans
10 Insulation:In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
required by the prescriptive or performance requirements.See Section 150.0(m)1.
Registration Number: 417-A0013621A-M0100001A-0000 Registration Date/Time: 2017-02-09 10:41:15 HERS Provider:CHEERS
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-02-09 10:41:17
Schema Version: 2013.1.008
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 )
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
11 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
12 A thermostat shall be installed that meets the requirements of Section 110.2(bi4nd Section 110.2(c).
13 The thermostat shall be installed in accordance with the manufacturers published installation specifications
14 First stage of heating shall be assigned to heat pump heating.
15 Second stage back up heating shall be set to come on only when the indoor settemperature cannot be met.
The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 417-A0013621A-M0100001A-0000 Registration Date/Time: 2017-02-09 10:41:15 HERS Provider:CHEERS
CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-02-09 10:41:17
Schema Version: 2013.1.008